ARCO 400. Technical Data

Similar documents
CMC 256plus - protection relay test set and universal calibrator

Appendix A: Specifications

PQube 3 Specifications

Appendix A: Specifications

DOBLE F6150e TECHNICAL SPECIFICATIONS

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Specifications. PCI Bus. Analog Input Input Characteristics

Instrument. Specifications OR34/35. SmartRouter. 2 to 8 Channels Multi-Analyzers. Controller Unit TECHNICAL SPECIFICATIONS

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

TE W Single Output External Power Test & Measurement/Industrial Series

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

8588A Reference Multimeter

TE60 60W Single Output External Power Test & Measurement/Industrial Series

RS Pro ENGLISH. Datasheet

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

8558A 8 1/2 Digit Multimeter

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

LFWLP W 12V 15.00A 25.00A 92%

High precision measurement system for current and voltage IHC-A/B-RM01/03

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

Chapter 6 Specifications

TE90 90W Single Output External Power Test & Measurement/Industrial Series

Voltage Adjustment. Load Regulation

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Vector Network Analyzers ZVB

SWT 3000 Teleprotection technical data siemens.com

Chapter 5 Specifications

PQube 3 Specifications

DS10000ULFS-10V/10kA

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

R&S ZVT Vector Network Analyzer Specifications

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Overcurrent Protection / 7SJ45

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Fluke 5820A Oscilloscope Calibrator Specifications

Type CP-S, CP-C & CP-A Switch mode

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

RS Pro ENGLISH. Datasheet

Function/Arbitrary Waveform Generator

R&S ZNC Vector Network Analyzer Specifications

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Keysight Technologies N9320B RF Spectrum Analyzer

Output Voltage* (nom.)(adjustable)

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

LB115S 115W Single Output

Agilent N9320B RF Spectrum Analyzer

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

FREJA 306 Relay Testing System

NI DAQPad -6020E Family Specifications

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Fluke 83V and 87V Digital Multimeters

LINAX 4000L Continuous-line recorder

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

TE40 40W Single Output External Power Test & Measurement/Industrial Series

DSA700 Series Spectrum Analyzer

NI PXI-4461 Specifications

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Doc. EA Model Number:

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

NI 6013/6014 Family Specifications

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

R&S ZNB Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications

5500A. Multi-Product Calibrator. Extended Specifications 2005

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

50W Constant Current (700mA) Dimming LED Driver

EMC standards. Presented by: Karim Loukil & Kaïs Siala

5520A. Multi-Product Calibrator. Extended Specifications 2005

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Power supply CP-E 24/2.5

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Function/Arbitrary Waveform Generator

Racal Instruments. Product Information

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

Transcription:

Technical Data

OMICRON electronics GmbH 2017. All rights reserved. This technical data was extracted from the following manual: ENU 1119 04 03 All rights including translation reserved. Reproduction of any kind, for example, photocopying, microfilming, optical character recognition and/or storage in electronic data processing systems, requires the explicit consent of OMICRON. The document content represents the technical status at the time of writing and is subject to change without prior notice. We have done our best to ensure that the information given in this document is useful, accurate and entirely reliable. However, OMICRON does not assume responsibility for any inaccuracies which may be present. OMICRON electronics translates this document from the source language English into a number of other languages. Any translation of this document is done for local requirements, and in the event of a dispute between the English and a non-english version, the English version of this document shall govern. 2 OMICRON

Technical data 1 Technical data ARCO 400 is calibrated at + 23 C (+ 73.4 F). All guaranteed specified values are valid for the period of one year after factory calibration and within a temperature range of 23 C ± 5 C (73.4 F ± 9 F) at nominal value after a warm-up phase of more than 25 minutes. 1.1 Control 1.1.1 Technical data of the communication ports Figure 2-1: ARCO 400 Communication ports Two USB ports and Ethernet ports ETH1/ETH2 USB type USB 2.0 high speed up to 480 Mbit/s USB connector USB type A (for future use of USB peripherals) Output current 500 ma max. USB type USB 2.0 high speed up to 480 Mbit/s; USB 1.1 compatible USB connector USB type B USB cable USB 2.0 high speed type A-B, 2 m/ ft ETH type 10/100/1000Base-TX 1 (twisted pair, auto-mdi/mdix or auto-crossover) ETH connector RJ45 ETH cable type LAN cable of category 5 (CAT5) or better 2 ETH port status LED Depending on the ETH type of your interface board s counterpart, the status LED s behavior varies. Physical link established, port active: Mbit/s Active LED ON 10 yellow 100 green 1000 yellow + green ETH Power over Ethernet (PoE) If there is traffic via an ETH port, the active LEDs start blinking. IEEE 802.3af compliant. Port capability limited to 2 x Class 3 (12.95 W) power devices. 1. 10 Base = 10 Mbit/s transfer rate; 100 Base = 100 Mbit/s transfer rate; 1000 Base = 1000 Mbit/s transfer rate 2. Shielded LAN cable required. OMICRON 3

1.1.2 Clock accuracy All signals that are generated or measured by ARCO 400 are referenced to a common time base that is specified as follows: Clock accuracy Clock performance Stratum 3 (ANSI/T1.101-1987) Frequency drift (over time) 24 hours < ± 0.37 ppm (± 0.000037 %) 20 years < ± 4.0 ppm (± 0.0004 %) Frequency drift (over temperature range) < ± 0.28 ppm (± 0.000028 %) Frequency resolution (signal generation) < 5 μhz 1.1.3 Synchronization accuracy The specifications below refer to the internal time base. For the accuracy values of outputs and inputs in reference to absolute time, you need to add the error of the respective channel. Synchronization accuracy IEEE 1588 Offset (UTC) Error < 100 ns 1 Pulling range ± 100 ppm (± 0.01 %) 1. Depends on the PTP master clock accuracy. 4 OMICRON

Technical data 1.2 Current output specifications General current output specifications Number of outputs 3 Ranges Range I 0... 1.25 A Range II 0... 12.5 A Range III 0... 8 V (for more details refer to section Low level output specifications on page 13) Frequency Range 0... 599 Hz Configurations (AC) L-N 3 x 1.25 A L-N 3 x 12.5 A L-N 3 x 8 V Configurations (DC) L-N 3 x ± 1.25 A L-N 3 x ± 12.5 A L-N 3 x ± 11.3 V Connection Test interface Potential group Test interface; see section 1.8.1 "Isolation coordination diagram" on page 17. The amplifier is fully protected against short and open circuit. The outputs are shorted when they are not in operation. OMICRON 5

1.2.1 Signal quality of current output Typical Guaranteed (1 year) AC accuracy 1 50/0 Hz Error < 0.04 % of rd. Error < 0.08 % of rd. + 0.01 % of rg. + 0.02 % of rg. 100Hz Error <0.08% of rd. Error < 0.15 % of rd. + 0.02 % of rg. + 0.05 % of rg. 250Hz Error <0.48% of rd. Error < 0.95 % of rd. + 0.02 % of rg. + 0.05 % of rg. 599Hz Error <1.48% of rd. Error < 2.45 % of rd. + 0.02 % of rg. + 0.05 % of rg. Phase error to V 1, 2 a1 50/0 Hz < 0.05 < 0.10 599 Hz < 0.25 Phasor error to UTC 1 50/0 Hz < 0.05 < 0.20 THD+N at 50/0 Hz < 0.10 % < 0.25 % (bandwidth = 20 khz) DC offset Range I < 100 µa < 300 µa Range II < 1 ma < 3 ma DC resolution Range I < 100 µa Range II < 1 ma Temperature drift +20 C +50 C (+ 8 F... + 122 F) - 10 C... + 20 C (+ 14 F... + 8 F) <25ppm/K <50ppm/K < 50 ppm/k < 100 ppm/k 1. Load impedance Z l 0.5 Ω in 12.5 A range and 1 Ω in 1.25 A range. For higher load impedances consider the influence of the output impedance. 2. The phase error refers to the first voltage output. OMICRON

Technical data 1.2.2 Performance data of current output The performance test values below apply to the following test conditions: The outputs are set to 50/0 Hz and symmetric conditions (0, 120, 240 ). The outputs are connected to resistive loads. No overload is indicated. Compliance voltage 1, 2 Max. compliance voltage Output power AC 3, 4 Typical >12V (RMS) >18V (DC) 18 V (DC) 3x95W at 8A 12.5A Guaranteed 3x85W at 8A 12.5A 1. Compliance voltage is the maximum voltage a current source will reach in its attempt to generate the programmed current. You can individually set the values for the compliance voltage. 2. For currents > 8 A, the compliance voltage is reduced to % of max. compliance voltage (- 1.3 V/A) 3. Data valid for symmetric conditions (0, 120, 240 ). 4. Output power guaranteed at test interface connector at the ARCO 400 front panel. Maximum output power The diagram below shows the typical output power capability of ARCO 400 with a constant gradient up to 8 A. Above this value, the compliance voltage decreases and therefore, limits the maximum possible output power. 100 80 Max. output power (W) 0 40 20 I1 I2 I3 0 0 2.5 5 7.5 10 12.5 Output current (A) OMICRON 7

Duty cycle of output power Continuous operation or 100 % duty cycle is defined as an ARCO 400 test set being able to typically provide a specified current and load for at least 30 minutes. A duty cycle of 75 %, for example, means that the ARCO 400 test set provides the specified current and load for 75 % of the time and needs the remaining 25 % of the time to cool off (for example: 180 s on and 0 s off). Duty cycle at + 25 C (+ 77 F) ambient temperature 100 80 Duty cycle (%) 0 40 0. Ω 20 0.45 Ω 0.3 Ω 0.15 Ω 0 Ω 0 0 2.5 5 7.5 10 12.5 Output current (A) Duty cycle at + 50 C (+ 122 F) ambient temperature 100 80 Duty cycle (%) 0 40 0. Ω 20 0.45 Ω 0.3 Ω 0.15 Ω 0 Ω 0 0 2.5 5 7.5 10 12.5 Output current (A) 8 OMICRON

Technical data 1.3 Voltage output specifications General voltage output specifications Number of outputs Ranges Range I (2 individual triples with common neutral) 0... 8 V (for more details refer to section Low level output specifications on page 13) Range II 0... 150 V (Range II with 150 V is optional 1 ) Frequency range 0... 599 Hz Configurations (AC) L-N x 8 V L-N x 150 V Connection Test interface Potential group Test interface; see section 1.8.1 "Isolation coordination diagram" on page 17. 1. Ordering information for x 150 V option: If you order this option, a 150 V range is added to the x 8 V amplifier. The 150 V range is used for testing recloser controls that require higher voltage amplitudes. Order number: VEHO0007 The amplifier is fully protected against short and open circuit. The outputs are open when they are not in operation. OMICRON 9

1.3.1 Signal quality of voltage output AC accuracy 1 Typical 50/0 Hz Error < 0.04 % of rd. + 0.01 % of rg. 100Hz 250Hz 599Hz Phase error to V a10 1, 2 Error <0.08% of rd. + 0.02 % of rg. Error <0.48% of rd. + 0.02 % of rg. Error <1.48% of rd. + 0.02 % of rg. 50/0 Hz < 0.05 < 0.10 599 Hz < 0.25 Phasor error to UTC 1 1. The maximum output current for high accuracy is I Load < 50 ma in a 150 V range. 2. The phase error refers to the first voltage output. Guaranteed (1 year) Error < 0.08 % of rd. + 0.02 % of rg. Error < 0.15 % of rd. + 0.05 % of rg. Error < 0.95 % of rd. + 0.05 % of rg. Error < 2.45 % of rd. + 0.05 % of rg. 50/0 Hz < 0.05 < 0.20 THD+N at 50/0 Hz < 0.10 % < 0.25 % (bandwidth = 20 khz) DC offset < 10 mv < 20 mv DC resolution < 10 mv Temperature drift +20 C...+50 C <25ppm/K <50ppm/K (+ 8 F... + 122 F) - 10 C... + 20 C (+ 14 F... + 8 F) < 50 ppm/k < 100 ppm/k 10 OMICRON

Technical data 1.3.2 Performance data of voltage output To improve the output duration, the compliance voltage of the voltage output can be configured to limit the power dissipation in the linear amplifiers. The optimum compliance voltage for each controller adapter is automatically set (because of the smart automatic controller adapter detection). The performance test values below apply to the following test conditions: The outputs are set to 50/0 Hz and symmetric conditions (0, 120, 240 ). The outputs are connected to resistive loads. No overload is indicated. Typical Guaranteed Output current (AC) per channel 280 ma 250 ma total max. 1400 ma Compliance voltage range (DC) 75 V 225 V 75 V... 225 V Output power (AC) 1, 2 3 x 42 W at 150 V 3 x 37.5 W at 150 V 1. Data valid for symmetric conditions in both triples (0, 120, 240 ). 2. Output power guaranteed at test interface connector at ARCO 400 front panel. Maximum output power The diagram below shows the typical output power capability of ARCO 400. 50 40 Output power per phase (W) 30 20 10 0 0 25 50 75 100 125 150 Output voltage (V) OMICRON 11

Continuous output power for symmetric conditions in both triples Continuous operation is defined as an ARCO 400 test set being able to typically provide a specified voltage and load for at least 30 minutes. The diagram below shows the continuous output power with optimized compliance voltage. 40 Output power per phase (W) 30 20 10 + 23 C / + 73.4 F + 50 C / + 122 F 0 0 25 50 75 100 125 150 Output voltage (V) 12 OMICRON

Technical data 1.4 Low level output specifications The voltage and current generators have three high accuracy low level voltage triples, i.e., nine configurable analog low level outputs. These nine low level outputs are used to simulate unconventional CTs/VTs either in linear or in Rogowski mode. When simulating Rogowski sensors, the output voltage is proportional to the derivative of the current with respect to time (di(t)/dt). An additional high accuracy low level voltage output (i.e., a tenth low level output) is used to simulate automatically calculated ground current or voltage (I E /V E ) by summing up one assigned generator triple. General output specifications Number of outputs 10 Range 0... 8 V Frequency range 0... 599 Hz Maximum output current 1 ma 1 Maximum output capacity Stable for all capacitive loads Connection Test interface Potential group Test interface; see section 1.8.1 "Isolation coordination diagram" on page 17. 1. Overload indication. 1.4.1 Signal quality of low level outputs Typical Guaranteed AC accuracy 1 50/0 Hz Error < 0.04 % of rd. + 0.01 % of rg. 599Hz Error <0.08% of rd. + 0.02 % of rg. Phase error to V 2, 4 a1 50/0 Hz < 0.05 < 0.10 599 Hz < 0.25 Phasor error to UTC 4 < 0.05 < 0.20 1. The maximum output current for high accuracy is I Load < 1 ma in an 8 V range. 2. The phase error refers to the first voltage output. Error < 0.08 % of rd. + 0.02 % of rg. Error < 0.25 % of rd. + 0.05 % of rg. THD+N at 50/0 Hz < 0.10 % < 0.25 % (bandwidth = 20 khz) DC offset < 500 µv < 1 mv DC resolution < 500 µv Temperature drift +20 C...+50 C < 25 ppm/k < 50 ppm/k (+ 8 F... + 122 F) - 10 C... + 20 C (+ 14 F... + 8 F) < 50 ppm/k < 100 ppm/k OMICRON 13

1.5 Binary inputs Binary inputs: BINARY INPUT 1... Number of binary inputs Number of potential groups Type Wet Sampling frequency 10 khz Time resolution 100 µs Debounce time 0 100ms 1 (refer to section 1.5.2 "Debouncing input signals" on page 15) Deglitch time 100 µs 100 ms 1 (refer to section 1.5.1 "Deglitching input signals" on page 15) Rated input voltage 250 V CAT III (max. permitted input voltage) Threshold voltage range 5 V... 250 V 1 Nominal threshold voltage Configurable (is automatically set via cable detection) 1 Resolution 1 V Trigger criteria DC voltage compared to threshold voltage 1 Ternary trigger BIN IN 1... 3 Simultaneous trigger on positive and negative threshold. BIN IN 4... Trigger on positive threshold only. Threshold accuracy 5 % of reading +/- 1 V offset (for upper and lower threshold) Nominal hysteresis 10 % of threshold Input impedance Configurable (automatically set via cable detection) 148 kω (for ADC 2 measuring input) Connection Potential group Test interface Test interface; see section 1.8.1 "Isolation coordination diagram" on page 17. 1. ARCO 400 supports the settings that are either set automatically via cable detection or configured manually in the ARCO Control software. 2. ADC = Analog-to-Digital Converter 14 OMICRON

Technical data 1.5.1 Deglitching input signals In order to suppress short spurious pulses, you can configure a deglitching algorithm. The deglitch process results in an additional dead time and introduces a signal delay. In order to be detected as a valid signal level, the level of an input signal must have a constant value at least during the deglitch time. The figure below illustrates the deglitch function. Input signal Input signal deglitched T deglitch T deglitch Figure 2-2: Signal curve, deglitching input signals 1.5.2 Debouncing input signals For input signals with a bouncing characteristic, you can configure a debounce function. This means that the first change of the input signal causes the debounced input signal to be changed and then be kept on this signal value for the duration of the debounce time. The debounce function is placed after the deglitch function described above, and both are realized by the firmware of ARCO 400 and are calculated in real time. The figure below illustrates the debounce function. On the right-hand side of the figure, the debounce time is too short. As a result, the debounced signal rises to high once again, even while the input signal is still bouncing and does not drop to low level until the expiry of another period T debounce. Input signal Input signal debounced T debounce T debounce T debounce Figure 2-3: Signal curve, debounce input signals OMICRON 15

1. Binary outputs Binary outputs: BINARY OUTPUT 1... 9 Number of binary outputs 9 Number potential groups 3 (1-3 / 4- / 7-9) Type Potential-free contacts, NO 1 Rated input voltage 250 V CATIII AC loading V max =250V; I max =0.5A DC loading V max =250V Carry capacity 0.5 A continuous at 0 C (140 F) Electrical lifetime 100 k switching cycles at 230 V / 0.5 A and resistive load (AC) Total make time < ms Total break time < 3 ms Functional isolation SEC Creepage/clearance > 1 mm (0.04 ") Pick-up time Approx. ms Fall back time Approx. 3 ms Bounce time Approx. 0.5 ms Connection Test interface Potential group Test interface; see section 1.8.1 "Isolation coordination diagram" on page 17. 1. NO = normally open 1.7 Power supply Main power supply Voltage, single phase Nominal voltage 100 V... 240 V Operational range 85 V... 24 V Nominal current at < 170 V 10 A max. at > 170 V 8 A max. Frequency Nominal frequency 50/0 Hz Operational range 45 Hz... 5 Hz Overvoltage category II Connection C14 connector according to IEC 0320-1 Potential group Mains; see section 1.8.1 "Isolation coordination diagram" on page 17. 1 OMICRON

Technical data 1.8 Isolation coordination Isolation coordination Overvoltage category (mains) II Pollution degree 2 Measurement category (BINARY INPUTS/OUTPUTS) CAT III / 250 V (RMS) CAT IV / 150 V (RMS) 1.8.1 Isolation coordination diagram The product safety requirements and the corresponding isolation coordination comply with standards IEC 1010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) and IEC 1010-2-030 (Particular requirements for testing and measuring circuits). For more detailed information, refer to the standards. Control: Potential group to control the ARCO 400 test set is considered to be accessible (i.e. touchable). Test interface: Isolated potential group to connect the device under test. Mains: Line input to supply the ARCO 400 test set with power. OMICRON 17

Mains Test interface 4 5 Power supply AC DC 1 Current output (3 x I) Voltage output ( x V) PE 2 Control ETH1 ETH2 CPU Isolation 3 Low level output (1 x V) Binary input (1 ) 1 2 3 4 5 USB PC Binary output (1 9) 1, 2, 3 4, 5, 7, 8, 9 Potential groups Isolation 1 Mains Test interface RI 1 240 V / OVC III 2, IEC 1010-1 2 3 4 5 Mains Control RI 1 240 V / OVC III 2, IEC 1010-1 Control Test interface RI 1 250 V / CAT III, IEC 1010-1 and IEC 1010-2-030 Mains PE 3 BI 4 240 V / OVC III 2, IEC 1010-1 Test interface PE 3 BI 2 250 V / CAT III, IEC 1010-1 and IEC 1010-2-030 Test interface Test interface WI 5 Functional isolation (with > 1.5 mm / 0.0 " creepage) between secondary isolation groups (current amplifier, voltage amplifier, binary inputs 1-, binary outputs 1-9) 1. Reinforced isolation 2. OVC = Overvoltage category 3. PE = protective earth 4. Basic isolation 5. Working isolation (not safety-relevant) 18 OMICRON

Technical data 1.9 Environmental conditions 1.9.1 Climate Climatic specifications Operating temperature - 10 C... + 50 C / + 14 F... + 122 F Storage and transportation - 25 C... + 70 C / - 13 F... + 158 F Maximum altitude Operating 4,000 m / 13,000 ft Non-operating 15,000 m / 49,000 ft Humidity 5 % 95 % relative humidity; no condensation 1.9.2 Mechanics Size, weight, and protection Dimensions W x H x D 200 mm x 350 mm x 455 mm / 7.87 " x 13.78 " x 18.11 " Weight 10 kg / 22 lbs Ingress protection rating IP31 according to EN 0529 IP32 with front cover OMICRON 19

1.10 Relevant standards 1.10.1 Climate Damp heat specifications Damp heat Dry heat Cold temperatures 12h +25 C/+77 F and 12 h + 55 C/+ 131 F; 95 % r.h. + 50 C/+ 122 F 1 h operated + 70 C/+ 158 F 9 h not operated - 10 C/+ 14 F 1 h operated - 25 C/- 13 F 9 h not operated IEC 008-2-30 ( cycles) IEC 008-2-2 IEC 008-2-1 1.10.2 Mechanics Standards for testing mechanical conditions IEC 0721-3-7-7M3 Classification of mechanical conditions: Use at location and direct transfer between locations with significant vibrations or with high level shocks. The handling and transfer of products is rough. (for not operated mode) IEC TR 0721-4-7 Classification of environmental conditions Data for testing mechanical conditions Basic standard Description Test values Device conditions IEC 008-2-4 Random vibration 4.9 g RMS 10 2000 Hz, 30 min not operated IEC 008-2-27 Shock response 30 g 11 ms (half sine) (3 shocks +/-) not operated IEC 008-2-31 Free fall 0.5 m /1.4 ft two drops, transport position not operated 20 OMICRON

Technical data 1.10.3 Electromagnetic compatibility EMC standards Emission Europe EN 132-1; EN 1000-3-2; EN 1000-3-3, EN 55022 Class A International IEC 132-1; IEC 1000-3-2; IEC 1000-3-3, CISPR 22 Class A USA FCC Subpart B of Part 15 Class A Immunity Europe EN 132-1 International IEC 132-1 Standards and data for emission testing Basic standard Description Port Limit Frequency range EN55011/22 Radiated Enclosure A 30 MHz 13 GHz FCC, 47 CFR Part 15 EN55011/22 Conducted LAN 1 FCC, 47 CFR Part 15 AC power EN1000-3-2 Harmonic current AC power emission EN1000-3-3 Voltage fluctuation AC power and flicker 1. Shielded LAN cable required. A A 0.15 30MHz OMICRON 21

Standards and data for immunity testing Basic standard Description Tested port Test values Performance criterion IEC 1000-4-2 ESD Enclosure 4 kv contact A 8kV air IEC 1000-4-3 EM field Enclosure 10 V/m 80 1000 MHz A 3V/m 1.4 2GHz 1V/m 2 2.7GHz IEC 1000-4-8 Rated power frequency magnetic field Enclosure 30 A/m A IEC 1000-4-4 Burst AC power 2 kv / 5 khz L Ground N Ground PE Ground A LAN, controller interface 2kV / 5kHz Ground USB 500 V / 5 khz Ground IEC 1000-4-5 Surge AC power 1 kv L N B 2kV 1 L, N PE LAN 1 kv PE IEC 1000-4- Conducted RF AC 3 V 0.15 80 MHz A LAN, controller interface IEC 1000-4-11 Voltage dips AC power to 0 % 1 period A to 40 % 10 periods A to 70 % for 25 periods A to 0 % during 250 periods C 1. Taking measurements during high disturbances at the mains port is not intended. Therefore, the device switches off when testing 2 kv L/N to PE. 22 OMICRON

Technical data 1.10.4 Safety Safety standards Europe EN 1010-1; EN 1010-2-030 Isolation of SELV 1 interface complies with EN 0950-1 International IEC 1010-1; IEC 1010-2-030 USA UL 1010-1; UL 1010-2-030 Canada CAN/CSA-C22.2 No 1010-1-04; CAN/CSA-C22.2 No 1010-2-030-12 Certificate Isolation Protection class I (electrical earth) Pollution degree 2 Isolation of functional groups Standards IEC 1010-1 and IEC 1010-2-030 1. SELV = Safety extra low voltage according to IEC 0950 OMICRON 23

1.11 Calibration interval OMICRON suggests that you calibrate your test sets at least once a year. The drift of test equipment, that is, the change of accuracy over time, depends strongly on environmental conditions and the application field. Excessive use or applied mechanical and/or thermal stress may result in a necessity of shorter calibration intervals. Moderate working environments, on the other hand, allow you to increase the calibration interval to once every two or even three years. Particularly in cases of extended calibration intervals, verify the accuracy of the test set by cross-referencing the measurement results with traceable reference equipment either on a regular basis or prior to use. You can accomplish that by, for example, using a typical, often-used device under test as a reference, or by using measurement equipment with a certified high accuracy. Should the test equipment fail, get it either calibrated or repaired immediately. Limited warranty: OMICRON guarantees that the test set is working properly within the quantified specifications at the time of calibration. OMICRON offers a free-of-charge repair and readjustment for equipment that fails or drifts out of specification within the first 24 months after first shipment (new products), or months after repairs. The limited warranty excludes repair cases due to mechanical damage, high voltage or current injection, or any kind of use deviant from the equipment s designated use. 24 OMICRON