40Gb/s Coherent DP-PSK for Submarine Applications

Similar documents
40 Gb/s and 100 Gb/s Ultra Long Haul Submarine Systems

from ocean to cloud TCM-QPSK PROVIDES 2DB GAIN OVER BPSK IN FESTOON LINKS

UNREPEATERED SYSTEMS: STATE OF THE ART

from ocean to cloud USING COHERENT TECHNOLOGY FOR SIMPLE, ACCURATE PERFORMANCE BUDGETING

Single- versus Dual-Carrier Transmission for Installed Submarine Cable Upgrades

from ocean to cloud EFFICIENCY OF ROPA AMPLIFICATION FOR DIFFERENT MODULATION FORMATS IN UNREPEATERED SUBMARINE SYSTEMS

Current Trends in Unrepeatered Systems

UNREPEATERED SYSTEMS: STATE OF THE ART CAPABILITY

EXTREMELY LONG-SPAN NON-REPEATERED SUBMARINE CABLE SYSTEMS AND RELATED TECHNOLOGIES AND EQUIPMENT

Fibers for Next Generation High Spectral Efficiency

SUBMARINE SYSTEM UPGRADES WITH 25 GHZ CHANNEL SPACING USING DRZ AND RZ-DPSK MODULATION FORMATS

Emerging Subsea Networks

from ocean to cloud DIMINISHED NONLINEAR IMPACT OF BIT-ALIGNED POLARIZATION MULTIPLEXING WITH ADVANCED MODULATION FORMATS ON SUBSEA CABLES

from ocean to cloud THE FUTURE IS NOW - MAXIMIZING SPECTRAL EFFICIENCY AND CAPACITY USING MODERN COHERENT TRANSPONDER TECHNIQUES

Optical Transport Tutorial

Emerging Subsea Networks

Ultra-long Span Repeaterless Transmission System Technologies

from ocean to cloud LARGE CAPACITY LONG REACH UNREPEATERED TRANSMISSION USING FIBER A EFF -MANAGED SPAN WITH OPTIMIZED AMPLIFICATION SCHEME

from ocean to cloud WELCOME TO 400GB/S & 1TB/S ERA FOR HIGH SPECTRAL EFFICIENCY UNDERSEA SYSTEMS

Optical Measurements in 100 and 400 Gb/s Networks: Will Coherent Receivers Take Over? Fred Heismann

Emerging Subsea Networks

Emerging Subsea Networks

Emerging Subsea Networks

30 Gbaud Opto-Electronics and Raman Technologies for New Subsea Optical Communications

Network Challenges for Coherent Systems. Mike Harrop Technical Sales Engineering, EXFO

Next-Generation Optical Fiber Network Communication

A 24-Dimensional Modulation Format Achieving 6 db Asymptotic Power Efficiency

Emerging Subsea Networks

from ocean to cloud LATENCY REDUCTION VIA BYPASSING SOFT-DECISION FEC OVER SUBMARINE SYSTEMS

from ocean to cloud Power budget line parameters evaluation on a system having reached its maximum capacity

Multi-format all-optical-3r-regeneration technology

Global Consumer Internet Traffic

Performance Limitations of WDM Optical Transmission System Due to Cross-Phase Modulation in Presence of Chromatic Dispersion

CodeSScientific. OCSim Modules 2018 version 2.0. Fiber Optic Communication System Simulations Software Modules with Matlab

Lecture 7 Fiber Optical Communication Lecture 7, Slide 1

40Gb/s & 100Gb/s Transport in the WAN Dr. Olga Vassilieva Fujitsu Laboratories of America, Inc. Richardson, Texas

Analysis of Self Phase Modulation Fiber nonlinearity in Optical Transmission System with Dispersion

Emerging Subsea Networks

Peter J. Winzer Bell Labs, Alcatel-Lucent. Special thanks to: R.-J. Essiambre, A. Gnauck, G. Raybon, C. Doerr

RZ-DPSK 10GB/S SLTE AND ITS TRANSMISSION PERFORMANCE ASSESSMENTFOR APPLICATION TO TRANS-PACIFIC SUBMARINE CABLE SYSTEMS

from ocean to cloud Fraunhofer Institute for Telecommunications, Heinrich-Hertz-Institut, Einsteinufer 37, D-10587, Berlin, Germany

Integrated Circuits for Wavelength Division De-multiplexing in the Electrical Domain

Emerging Subsea Networks

Emerging Subsea Networks

Polarization Optimized PMD Source Applications

Next Generation Optical Communication Systems

Performance Evaluation of Hybrid (Raman+EDFA) Optical Amplifiers in Dense Wavelength Division Multiplexed Optical Transmission System

from ocean to cloud LOW COMPLEXITY BACK-PROPAGATION FOR UPGRADING LEGACY SUBMARINE SYSTEMS

Qualifying Fiber for 10G Deployment

Performance Analysis Of Hybrid Optical OFDM System With High Order Dispersion Compensation

Phase Modulator for Higher Order Dispersion Compensation in Optical OFDM System

CodeSScientific OCSim Modules Modern Fiber Optic Communication Systems Simulations With Advanced Level Matlab Modules APPLICATIONS

from ocean to cloud Copyright SubOptic2013 Page 1 of 5

Spectral-Efficient 100G Parallel PHY in Metro/regional Networks

Design and Manufacturing Process Management for Tera-bit/FP Class Submersible Plant

Emerging Subsea Networks

RAMAN OPENS UP BANDWIDTH ON NON-IDEAL FIBRES FOR UN-REPEATERED SYSTEMS

Enabling technology for suppressing nonlinear interchannel crosstalk in DWDM transoceanic systems

8 10 Gbps optical system with DCF and EDFA for different channel spacing

Innovations in Coherent Technologies for Subsea Transmission Systems

Optical Fibre Amplifiers Continued

The Challenges of Data Transmission toward Tbps Line rate in DWDM System for Long haul Transmission

Balanced hybrid and Raman and EDFA Configuration for Reduction in Span Length

S Optical Networks Course Lecture 4: Transmission System Engineering

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING. FINAL EXAMINATION, April 2017 DURATION: 2.5 hours

Emerging Subsea Networks

Design of an Optical Submarine Network With Longer Range And Higher Bandwidth

Polarization Mode Dispersion compensation in WDM system using dispersion compensating fibre

Single channel and WDM transmission of 28 Gbaud zero-guard-interval CO-OFDM

Emerging Subsea Networks

Performance Analysis of Direct Detection-Based Modulation Formats for WDM Long-Haul Transmission Systems Abstract 1.0 Introduction

Emerging Subsea Networks

Chirped Bragg Grating Dispersion Compensation in Dense Wavelength Division Multiplexing Optical Long-Haul Networks

Optical Single Sideband Modulation and Optical Carrier Power Reduction and CATV Networks

International Journal Of Scientific Research And Education Volume 3 Issue 4 Pages April-2015 ISSN (e): Website:

Improved Analysis of Hybrid Optical Amplifier in CWDM System

Performance Analysis of Optical Time Division Multiplexing Using RZ Pulse Generator

SPECTRAL HOLE BURNING EFFECTS AND SYSTEM ENGINEERING RULES FOR SYSTEM UPGRADES

ADVANCED OPTICAL FIBER FOR LONG DISTANCE TELECOMMUNICATION NETWORKS

The Reduction of FWM effects using Duobinary Modulation in a Two-Channel D-WDM System

Simulative Analysis of 40 Gbps DWDM System Using Combination of Hybrid Modulators and Optical Filters for Suppression of Four-Wave Mixing

WDM in backbone. Péter Barta Alcatel-Lucent

Dr. Monir Hossen ECE, KUET

Signal Conditioning Parameters for OOFDM System

Meeting The Challenge of Cloud Scale Connectivity. Abhijit Chitambar Ph.D. Principal Product Manager Infinera

XWDM Solution for 64 Terabit Optical Networking

RZ BASED DISPERSION COMPENSATION TECHNIQUE IN DWDM SYSTEM FOR BROADBAND SPECTRUM

A Technique to improve the Spectral efficiency by Phase shift keying modulation technique at 40 Gb/s in DWDM optical systems.

Laser Frequency Drift Compensation with Han-Kobayashi Coding in Superchannel Nonlinear Optical Communications

Radio over Fiber technology for 5G Cloud Radio Access Network Fronthaul

Emerging Subsea Networks

Performance Analysis of Dwdm System With Different Modulation Techique And Photodiode

Performance of A Multicast DWDM Network Applied to the Yemen Universities Network using Quality Check Algorithm

International Journal of Advanced Research in Computer Science and Software Engineering

1 COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.

FWM Suppression in WDM Systems Using Advanced Modulation Formats

Proposal of A Star-16QAM System Based on Intersymbol Interference (ISI) Suppression and Coherent Detection

Mitigation of Chromatic Dispersion using Different Compensation Methods in Optical Fiber Communication: A Review

50Gb/s technical feasibility analysis. Dekun Liu, Huawei Stanley Shuai, Source Sep, 2017

From static WDM transport to software-defined optics

Transcription:

4Gb/s Coherent DP-PSK for Submarine Applications Jamie Gaudette, Elizabeth Rivera Hartling, Mark Hinds, John Sitch, Robert Hadaway Email: <jamiega1@nortel.com> Nortel, 3 Carling Ave., Ottawa, ON, Canada Abstract: Performance of two variants of 46Gb/s coherent DP-PSK transceivers over repeatered links of 6 and 1 in length and unrepeatered links with span losses up to 75 db is presented. All transceivers in this work employ electronics for polarization state recovery as well as correction of CD, PMD, and all other deterministic linear impairments, thereby eliminating the need for optical compensation. 1. INTRODUCTION Dual Polarization Phase Shift Keying (DP- PSK) with coherent detection is an interesting alternative to traditional OOK/DPSK for submarine applications. Commercially available 46Gb/s DP-PSK transceivers offer up to eight times the raw spectral efficiency of existing state of the art RZ technology [1, 2]. Furthermore, when DP-PSK with coherent detection is paired with DSP, all deterministic linear impairments, such as CD and PMD, can be tracked and compensated. Thus, all optical compensation is removed from the physical layer. With favorable WDM properties and excellent noise tolerance, 46Gb/s DP-PSK can be positioned to overlay with 1Gb/s technology on existing submarine cables, or to build new capacity on dark fibers offering comparable reach to 1Gb/s technology, without costly re-engineering of the submarine cable plant. In this work, two implementations of DP- PSK are presented. In the first implementation, Dual Polarization Quaternary Phase Shift Keying (DP- QPSK) is transmitted. As shown in Figure 1-1, DP-QPSK offers 46Gb/s with an 11.5GHz NRZ line rate. In the second implementation, Dual Polarization Binary Phase Shift Keying is transmitted. To achieve an aggregate data rate of 46Gb/s while maintaining an 11.5GHz baud rate, two carriers are modulated and frequency division multiplexed (FDM) in one GHz optical channel. Frequency selectivity of coherent detection is used at the receiver to de-multiplex the FDM carriers, and avoid ultra narrow optical filters. This process is termed coherent frequency division multiplexing (CoFDM). In this implementation, 31.5GHz of optical bandwidth is required to offer a 46Gb/s line-rate on two CoFDM carriers modulated at 11.5Gbaud. Signal [dbm] -15-2 -25-3 -35 4G DP-BPSK CoFDM and 4G DP-QPSK 31.53 GHz 11.53 GHz 11.53 GHz 23 Gb/s DP-BPSK CoFDM 1555.9 1556 1556.1 1556.2 Figure 1-1 Spectral Occupancy of DP-BPSK CoFDM and DP-QPSK 2. REPEATERED APPLICATIONS DP-QPSK Experimental results were obtained during a field trial on a 6 trans-atlantic cable [3]. Nortel submarine line terminal equipment (SLTE) was placed on the ends of a dark fiber pair in the sub-sea link. No alterations were made to the line system. The SLTE consisted of Nortel s Optical Multi-service Edge 6 (OME6), Copyright 21 SubOptic Page 1 of 5

Dispersion [ps/nm] which housed all coherent transponders, and Nortel Common Photonics Layer (CPL), which provided optical multiplexing and amplification. Figure 2-1 illustrates the SLTE configuration. Field trial, measurements were taken on the 6 point to point trans-atlantic link, and the 12, trans-atlantic loopback. Figure 2-1 Nortel Repeatered SLTE Design The optical fiber in the submarine cable plant was a hybrid mixture of large core fiber (LCF, G.655) and reduced slope fiber (RSF, G.655), with periodic use of dispersion compensating fiber (DCF, G.654). Before performance was characterized, in-service CD and PMD measurements were taken with the coherent receiver. The in-service measured CD for both the 6 point-to-point and the 12, loopback is given in Figure 2-2. The measured mean PMD was 6ps for the 6 point-to-point link, and 13ps mean for the 12, trans-atlantic loopback. Trans-Atlantic Dispersion Profile x 14 1.2 6 Route.9 1 Loopback.6.3 -.3 -.6 -.9-1.2 154 1545 15 1555 156 1565 Figure 2-2. In-Service CD Measurement To estimate performance of a full-fill of 46Gb/s DP-PSK channels on a GHz optical grid, a grouping of 46Gb/s channels was moved across the operating bandwidth and the optical line performance was measured in three locations: mid-band, red-band edge and blue-band edge. Optical performance was measured as pre- FEC BER converted to dbq [2logQ]. The pre-fec BER is available from the coherent receiver, and can be accessed via the network management software. The effect of up to 1 WDM interferers was measured. Five idle channels were employed to consume unused power from the sub-sea amplifiers. The optical spectrum of the received signal in the midband test location is given in Figure 2-3. The optimal launch power was measured at -5 dbm per channel, per repeater for 4G DP-QPSK, and -6dBm per channel, per repeater for 46Gb/s DP-BPSK CoFDM. [dbm] -15-2 -25-3 -35 6 Atlantic Crossing Rx 1545 15 1555 156 Figure 2-3. Field Trial Rx Optical Spectrum The results of the performance measurements at 6 are given in Figure 2-4. Results clearly indicate that industrial margins are expected with a fullfill of 42x46Gb/s channels on a GHz ITU grid when 46Gb/s DP-BPSK CoFDM is employed. Results also indicate that 46Gb/s DP-QPSK is not well suited for trans-atlantic distances as low operating margins were observed, and large channel spacing were required. From other field trial measurements it was concluded that 46Gb/s DP-QPSK is better suited for links up to 4 in reach. The margin gained using DP-BPSK is due to increased phasenoise tolerance of each BPSK subcarrier. Copyright 21 SubOptic Page 2 of 5

Margin [dbq] 4 3.5 3 2.5 2 1.5 1.5 Estimated Trans-Atlantic Margin 1545 15 1555 156 Est. SOL 42x46Gb/s DP-BPSK GHz ITU Grid Est. SOL 5x46Gb/s DP-QPSK 4GHz Spacing Est. SOL 42x46Gb/s DP-BPSK Simulated Worst-Case Margin Figure 2-4. Trans-Atlantic Measured Operating Margins [2logQ] performance measurements of a single channel at 12, are given in Figure 2-5. To our knowledge, this is the longest 4G demonstration with real-time processing. It is important to note that this system was optimized for 6. Higher operating margins are expected on a properly optimized 12, system. An optical recirculation loop was used to further investigate the performance limitations of 46Gb/s DP-PSK. The recirculation loop was designed to closely resemble the physical properties of the trans-atlantic cable presented in this work. Figure 2-6 shows the experimental setup of the optical recirculation loop. 1.4 12, Atlantic Loopback Measured dbq Margin 1.2 Margin [dbq] 1.8.6.4 Figure 2-6 Optical Recirculation Experimental Configuration.2 Est. SOL 46Gb/s DP-BPSK Simulated Single Channel 1545 15 1555 156 Figure 2-5. 46Gb/s DP-BPSK Measured Opearting Margins over 1 [2logQ] The operating margins for 42x46Gb/s channels on the 6 Atlantic crossing were also simulated using our in-house split-step Fourier propagator. The worst case simulated channel is presented in Figure 2-4. In this case, a.25 dbq overestimation in worst case SOL performance was simulated when compared to measured operating margins. In addition to 6 point-to-point testing, the cable plant was looped back to create a 1 propagation distance. For this measurement, a single channel was swept across the available bandwidth as performance was measured in terms of pre- FEC BER converted to dbq. The Figure 2-7 Single Channel Recirculation of 46Gb/s DP-QPSK and 46Gb/s DP-BPSK In Figure 2-7, single channel performance of both 46Gb/s DP-QPSK and 46Gb/s DP- BPSK CoFDM is shown at varying distances. This experiment illustrates the additional reach achieved with DP-BPSK CoFDM in place of DP-QPSK as performance above the FEC limit was measured out to 14. 3. UNREPEATERED APPLICATIONS For traditional un-repeatered applications, the goal is to launch the highest possible per wavelength power into the stretched Copyright 21 SubOptic Page 3 of 5

conference & convention single span at the transmit end to maximize system. The maximum launch power is often limited by fiber nonlinearities, such as self-phase modulation (SPM), cross phase modulation (XPM), and stimulated Bouillon scattering (SBS). In the case where launch powers are limited such that sufficient cannot be provided for system operation, improvements can be realized by counter-pumped and co-pumped amplifiers. amplification increases signal powers further into the fiber, thus raising the average signal power in the fiber while reducing the peak power of the signals. When feasible, remote optically pumped amplifiers (ROPA) can be built into a cable plant to provide further improvements in system. Performance of 46Gb/s DP-QPSK over unrepeatered systems has been demonstrated in laboratory setups on stretched single spans with submarine quality low loss G.654 fiber, with effective span losses up to 75dB. A 75 db span loss corresponds to 415 of ultra low loss NDSF (.18dB/ loss). To allow effective link analysis, power taps were placed strategically to measure power evolution in the single stretched span. In this work we consider three primary unrepeatered solutions: (1) Counter- pumping only, (2) Co- + Counter, and (3) Co- + Counter with an in-line counter-pumped ROPA. The three experimental setups are shown in Figure 3-1, Figure 3-2 and Figure 3-3 respectively. Counter Pump Figure 3-1. Counter-Pump Configuration Copyright 21 SubOptic Co-Pump Counter Pump Figure 3-2. Co-Pump + CounterPump Configuration Co-Pump Counter& ROPA Pump ROPA Figure 3-3. Co-Pump + CounterPump + Counter Pumped ROPA The Co-Pump examined was a 7mW multi-laser diode (MLD) co-pump. The Counter-pump examined was a 3W Super Counter Pump (SCRP) as described in [4]. The ROPA pump was a 4mW MLD 148nm counter-pump. The ROPA was a single section of Erbium Doped Fiber (EDF) with input and output isolators. 3 was used for fiber propagation. An in-line variable optical attenuator () was used after of fiber propagation to adjust the unrepeatered span loss. A maximum number of 11 channels with 1GHz spacing were supported with this vintage of SCRP without ROPA. Current Counter- technology supports up to 44 channels with GHz channel spacing. A maximum of 16 channels with 1GHz channel spacing was supported with the ROPA solution. No optical compensation was required, as the coherent receiver eliminates effects of CD and PMD. Figure 3-4 outlines the results of the laboratory analysis. The single channel case provided the best performance. However, performance and maximum span loss decreased as additional channels were Page 4 of 5

added. To achieve optimum performance with multiple wavelengths, the launch power of all 46Gb/s transceivers was dropped to reduce the penalty incurred from XPM. Figure 3-5 illustrates the effect XPM has on the optimal launch power into the un-repeatered span. Performance [2logQ] 12.5 12 11.5 11 1.5 1 9.5 9 72 7 68 66 Measured Unrepeatered 11x4G - Counter 11x4G Co+Counter 16x4 - Co+Counter + Ropa 1x4G - Co+Counter + ROPA 8.5 6 62.5 65 67.5 7 72.5 75 Los s [db] Figure 3-4. Unrepeatered Performance vs Maximum for Un-Repeatered 76 16-Channels 74 Single Channel Max [db] Furthermore, industrial margins for a fullfull of 42x46b/s DP-BPSK CoFDM channels was presented for an aggregate data rate of over 1.9Tb/s per fiber pair across the Atlantic Ocean. In-service CD and PMD measurements at 6 and 1 using the coherent receiver are also presented. 5. REFERENCES [1] Roberts, K. et al., Performance of Dual- Polarization QPSK for Optical Transport Systems, JLT Vol 27, No 16, pp. 3546-59, 9 [2] L. Nelson, Performance of a 46Gbps Dual-Polarization QPSK Transceiver in High PMD Fiber Transmission Experiment, OFC8, PDP9 [3] Nortel Networks and Reliance GlobalCom, Nortel Achieves 1 4G Milestone on Submarine Cable, http://www2.nortel.com/go/news, September 1, 9 [4] Papernyi, S.B. et al., Third-Order Cascaded Amplification, OFC 2 Post-deadline Paper FB4-1. 64-1 -7.5-5 -2.5 2.5 5 Fiber (dbm Per Channel) Figure 3-5. Fiber vs Performance with Co-Pump Experimental results also indicate that, as expected, Co-Pumping and the addition of a ROPA significantly improved 46Gb/s DP-QPSK performance over the un-repeatered span when compared with Counter-pumping only. 4. CONCLUSIONS DP-PSK optical modulation for modems with coherent detection and DSP has been demonstrated at reaches as far as 12, on repeatered submarine systems, and on links with up to 75dB span losses on unrepeatered submarine systems. Copyright 21 SubOptic Page 5 of 5