FOLLOWSPOT CONTROLLER

Similar documents
VL1000 Software Version History VL1000 3/25/02 4/10/02 4/15/02 4/25/02 5/16/02 6/25/02 7/09/02 8/08/02

Introduction. Purpose

1503 Follow Spot Yoke, Source Four LED

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

1. ASSEMBLING THE PCB 2. FLASH THE ZIP LEDs 3. BUILDING THE WHEELS

USER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector

BMFL FollowSpot. Light source 1700 W OSRAM Lok-it! HTI 1700/PS. LIGHT OUTPUT lm, m, m.

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker

1. Safety instructions Control elements of the RoboSpot...4

Lighting Instruments. Main Brands of Ellipsoidals: Fresnel: instrument for shorter throws covering a large area with soft light (adjustable beam size)

DMX-CONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

(Wireless Solution)

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

Desktop Magnifier. User s Guide

RoboSpot Base Station

PERSONAL RECORD KEEPING

LED Followspot PRODUCT DATA. LED Followspot

Repair Instructions. Replacing and Installing a Sweep Motor. Elite Models that Apply: Phenom 1 & 2. Step Description Tools Picture

ivu Plus Quick Start Guide P/N rev. A -- 10/8/2010

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

DMX Channel Index. Software v

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Installing Brackets to Minimize Distortion in Your SMART Board 685ix Interactive Whiteboard System s Projected Image

Vinyl Cutter Instruction Manual

1200 DPS Programmable Digital Powder System

Automatic Tool Changer (ATC) for the prolight A Supplement to the prolight 1000 User s Guide

Philips Vari-Lite TECHNICAL FOCUS: PRODUCT IN DEPTH

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

PERSONAL RECORD KEEPING

Ohbot. Eyes turn. servo. Eyelids open. servo. Head tilt. servo Eyes tilt. servo. Mouth open servo. Head turn servo

reference guide reference guide reference guide

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

BLUEMOTION UXP, CDP, SD

Used Gear For Sale. Price includes 4 way case. Sold in case quantities only. Price includes 4 way case. Sold in case quantities only.

INSTALLATION INSTRUCTIONS

Used Gear For Sale. Price includes case. quantities only. Price includes 2 way. case. Sold in case. quantities only. Price includes 4 way

Installation Manual REbus Beacon. Part of the Pika Energy Island M

Jarvis standing desk. Assembly instructions. For assembly assistance, visit fully.com/howtojarvis or call or

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

MPA-9000 Universal Ceiling Projector Mount Kit

ivu Series TG Image Sensor

Start Here. Installing your Microtek ScanMaker 9800XL Plus PC:

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

PROFILE 500. Halogen profile-spot

MRI SIMULATOR PST OPERATOR MANUAL

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

ETC Installation Guide

ServoDMX OPERATING MANUAL. Check your firmware version. This manual will always refer to the most recent version.

Articulating TV/Monitor Grommet/Clamp Desk Mount Model: DE300S (Butterfly Series)

Print Head Installation Guide

Installation Guide Philips IntelliVue MP20/30/40/50/60/70 MX400/450/500/550/600/700/800 M-Series Arm Mounting Kit for Dräger Primus Anesthesia Machine

Footprint Mobile Assembly Instructions

Indoor Contact Input Photosensor

INSTALLATION MANUAL PBL-UMP

RPMSP Series Installation Guide

Maintenance Information

Alice Compact - LED 600W. Followspot. Type: Followspot Source: LED 600W Optics: 13 to 24 zoom Colour temperature: Cool White.

Model PRESET 8 Installation and Operations Manual

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Round or Square Chicago Plenum Down Light Housing with Lamp

Wiring Techniques for Wiring a Lamp

Arc Trainer Main Frame Assembly

iphone 4S Dismantling Instructions

WARNING: Prior to installation, turn the power off to the vending machine and unplug it from its power source. Also, make sure to level the machine.

PACIFIC FOLLOWSPOT OPERATION MANUAL

i2 MX USER MANUAL TABLE OF CONTENTS SECTION 1 i2 MX PART IDENTIFICATION SECTION 2 i2 MX RECEIVER AND ITA ENGAGEMENT AND DISENGAGEMENT

Installing the 3 Indexer: PRS Standard Tools

INSTALLATION MANUAL PBC-UMS

MONOPRICE. Above Fireplace Pull-Down Full-Motion TV Wall Mount. User's Manual P/N 27773

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Ayrton GHIBLI TECHNICAL FOCUS: PRODUCT IN DEPTH

STRIKEPACK F.P.S. DOMINATOR MODE UPGRADE

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

Source 4WRD. Installation and User Manual. PAR and PARNel Fixture Bodies. Version Part Number: 7067M Rev: B Released:

ABM International, Inc.

Disclaimers. Important Notice

Digital Director Troubleshooting

MARTIN TRACKPOD 2.0BETA. Getting Started. Fifth Edition: November Martin TrackPod 2.0 Page 1

A comprehensive trouble shooting guide for RISE

JUMBO STENCIL CUTTING MACHINE PARTS LIST AND OPERATING MANUAL

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA

TROUBLE-SHOOTING: Error States

Harmony Remote Repair

UPLIFT 2-Leg Height Adjustable Standing Desk

Start Here. Installing your Microtek ScanMaker i280

Follow Spotlight 575, 700, 1200 Watt Metal Halide 1000, 2000 Watt Tungsten-Halogen Rev. June 2005

English User's Guide

General Installation Instructions

Quick Start Guide. Contents

Assembly Guide for Printrbot - Simple Maker s Edition 1405

The Bowflex Revolution XP Home Gym Assembly Instructions. P/N: Rev ( /0 )

Customer Notice: Congratulations again on your SawStop purchase, and thank you! -SawStop Tualatin, OR

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

Transcription:

SOFTWARE VERSION 2.0 WWW.PRG.COM FOLLOWSPOT CONTROLLER USER MANUAL

AutoPar, Bad Boy, Best Boy, Followspot Controller, Mbox, Mini Node, Nocturne, Series 400, ReNEW, Super Node, V476, V676, and Virtuoso are trademarks of Production Resource Group, LLC, registered in the U.S. and other countries. All other brand names which may be mentioned in this manual are trademarks or registered trademarks of their respective companies. This manual is for informational use only and is subject to change without notice. Please check www.prg.com for the latest version. PRG assumes no responsibility or liability for any claims resulting from errors or inaccuracies that may appear in this manual. Followspot Controller User Manual Version as of: March 23, 2015 PRG part number: 02.9812.0060 Production Resource Group, LLC Dallas Office 8617 Ambassador Row, Suite 120 Dallas, Texas 75247 www.prg.com Followspot Controller User Manual 2015 Production Resource Group, LLC. All Rights Reserved.

TABLE OF CONTENTS Introduction About This Guide... 2 Additional Documentation... 2 Customer Service... 2 Description Overview... 3 Included Items... 4 Controls... 5 Installation Installing on a Bad Boy Luminaire... 6 Operation Luminaire Configuration... 12 Enabling Followspot Control on Bad Boy Luminaires... 12 Power Up... 14 Indicators... 14 Adjusting Parameters... 14 DMX Command Channels... 15 Updating FSC Software... 17 Troubleshooting Troubleshooting Guide... 18 Specifications Technical Specifications... 19 Revision History This manual has been revised as follows: Version Release Date Notes BASIC March 23, 2015 Initial Release FOLLOWSPOT CONTROLLER USER MANUAL 1

INTRODUCTION About This Guide This guide provides necessary information regarding product safety, installation, and operation for the following PRG equipment: + Followspot Controller (28.9812.0060) Familiarizing yourself with this information will help you get the most out of your PRG product. Additional Documentation For more information, refer to the following manuals: + Bad Boy Spot Luminaire User Manual (02.9812.0001.xx) Customer Service For technical assistance, contact the PRG International Service Center or contact your nearest PRG office. Contact information for all PRG office locations can be found on our website at: www.prg.com PRG Dallas (International Service) 8617 Ambassador Row, Suite 120 Dallas, Texas 75247 USA Phone: 214.630.1963 Fax: 214.630.5867 Service Fax: 214.638.2125 Service Email: orders@prg.com For Bad Boy support, please contact: Badboysupport@prg.com For additional resources and documentation, please visit our website at: www.prg.com 2 FOLLOWSPOT CONTROLLER USER MANUAL

DESCRIPTION Overview The Followspot Controller (FSC) is an accessory for the PRG Bad Boy Spot luminaire that allows a followspot operator to have manual control over the fixture s pan and tilt functions, as well as local control over Intensity, Iris, Zoom, and Edge. The lighting console operator still maintains control of all other internal functions (such as Color and Gobo) and can take over and/or override some of the functions that may be assigned to the local followspot operator. The Followspot Controller, which mounts to the right side of the luminaire near the front lens, allows local control of intensity via the fader, the beam-size iris via the side dial, as well as the full 8:1 zoom range and edge via the top dials. The FSC includes a handle which allows the operator full control over pan and tilt of the luminaire. The handle is complete with a hard-wired safety cable for operation at heights above an audience. The Followspot Controller includes a high visibility LCD screen to provide the followspot operator precise feedback levels for Intensity, Iris, Zoom, and Edge. A dial provides the operator output-level control for the LCD screen to minimize light pollution in sensitive applications. Power for the FSC is supplied by a power cable tied to the lowvoltage bus located in the luminaire s side arm. Control data is supplied by a CAT5e cable that plugs into the controller and into one of the Ethernet ports on the front of the luminaire. The Followspot Controller will work on any Bad Boy luminaire running Bad Boy software version 1.9.3 FSC or higher. Features: + Manual control over Pan and Tilt + Local control for Intensity, Iris, Zoom, and Edge + High-visibility LCD screen for attribute status + Easy grip handle for manual control of Pan and Tilt + Hard-wired safety cable + Dimming control over LCD screen + Easily attaches to any Bad Boy or Best Boy Spot luminaire Requirements: In order for the Followspot Controller to function properly, the following luminaire software version is required: + Bad Boy Spot Luminaire: v1.9fsc or greater For compatibility with all current functionality listed in this manual, v2.13 is required. FOLLOWSPOT CONTROLLER USER MANUAL 3

Included Items The following illustration shows all items included with the Followspot Controller. 1 2 3 1 Front Mount (10.9812.0688) 2 Two 8-32 x 5/8" SHCS Screws (53.6696.0625.0) 3 Controller Assembly (20.9812.0060 / 37498-10) 4 Rotating Handle (22.9812.0069) 5 Handle w/ Lanyard (22.9812.0067 / 37498-20) 6 Rear Mount (10.9812.0689) 7 10-32 x 5/8" SCB Screw (53.6515.0625.0) 8 Rubber Grommet (55.6541.0008) 9 6' Ethernet RJ-45 CAT5e Cable (25.9801.8006 / 37498-1C) 10 DC Power Cable (25.9812.1903 / 37498-18) 11 Carrying Case (21.9812.1202) 5 4 6 7 8 11 9 10 Figure 1: Included Items 4 FOLLOWSPOT CONTROLLER USER MANUAL

Controls The Followspot Controller contains the following components: Edge Control Dial Screen Brightness Control Dial Zoom Control Dial Beam-Size Iris Control Dial FRONT VIEW Pan/Tilt Control Handle LED Display SIDE VIEW Beam-Size Iris Control Dial Figure 2: Controls FOLLOWSPOT CONTROLLER USER MANUAL 5

INSTALLATION Installing on a Bad Boy Luminaire Use the following procedure to attach the Followspot Controller to a Bad Boy Spot luminaire. WARNING: Disconnect power from luminaire before installation. Step 1. Disconnect power from luminaire. Step 2. Remove Top Head Cover by removing two 8-32 x 3/8" PPB screws (Figure 3). Step 3. Remove Enclosure Intake Cover by loosening two captive screws. Step 4. Remove Pan-Side Yoke Cover by loosening four captive screws. Top Head Cover 8-32 x 3/8" PPB Screw (2) CAUTION: Hand tighten only. DO NOT use a power tool on Head Cover screws. 6-32 x 1/4" PPZ SEMS Screw (4) Pan-Side Yoke Cover Pan Shield 6-32 x 3/8" PFSS Black Screw (2) Captive Screw (4) Captive Screw (2) Intake Cover Figure 3: Removing Covers 6 FOLLOWSPOT CONTROLLER USER MANUAL

TILT J12 J16 J8 J9 J7 J6 J2 J3 J1 Step 5. Remove Pan Shield by removing two 6-32 x 3/8" PFSS black screws and four 6-32 x 1/4" PPZ SEMS screws. Step 6. Feed Ethernet RJ-45 CAT5e Cable (25.9801.8006 / 37498-1C) into yoke and through enclosure as shown in Figure 4. Step 7. At Interface panel, connect end of cable to ETHERNET INPUT. Step 8. Feed DC Power Cable (25.9812.1903 / 37498-18) into yoke as shown in Figure 4. Step 9. Attach red and black wires to terminal block as shown. Ethernet RJ-45 CAT5e Cable DC Power Cable J10 J11 Ethernet RJ-45 CAT5e Cable PAN J13 J14 J15 A B Ethernet RJ-45 CAT5e Cable DC Power Cable Figure 4: Installing Power and Data Cables FOLLOWSPOT CONTROLLER USER MANUAL 7

Step 10. At Enclosure Intake Cover, use clippers to create a notch for Ethernet Cable as shown in Figure 5. Intake Cover 2.5".4".4" Figure 5: Modifying Intake Cover Step 11. Replace Yoke Cover, Intake Cover, and Pan Shield. (Refer back to Figure 3.) When installing Intake Cover, route Ethernet Cable so that it passes through notch (created in previous step). Step 12. Modify and install Top Head Cover as follows: a. At corner of filter mesh, use clippers to create a hole for cables as shown in Figure 6. b. Punch a hole all the way through filter. c. Install Grommet (55.6541.0008) into new hole. d. Feed Ethernet Cable and DC Power Cable through grommet and out of Head Cover as shown. e. Set cover in place on luminaire head assembly and slide rear corners under lip of Aft Cover. f. At front of Head Cover, press with equal pressure on both sides until leading edge of cover snaps into place under front ring casting. (You will hear a "pop" when the cover snaps into place.) 8 FOLLOWSPOT CONTROLLER USER MANUAL

CAUTION: DO NOT use a power screwdriver when re-installing the head cover screws. This may damage the hole threads. Use a manual screwdriver only! g. Using manual #2 Philips screwdriver, re-install screw on left side of Head Cover (Figure 3). Mesh Filter Clippers Grommet Cables 0.9" 1.1" Front Mount 8-32 x 5/8" SHCS Screw (2) Rear Mount 10-32 x 5/8" SCB Screw Figure 6: Installing Front and Rear Mounts Note: The Rear Mount is used to connect the rear Handle. The Handle can be installed in one of two places. Refer to Figure 7 for a view of both options. Step 13. At Aft Cover, remove screw from one corner as shown in Figure 6. (This is where the Rear Handle will be installed.) FOLLOWSPOT CONTROLLER USER MANUAL 9

Step 14. Install Rear Mount (10.9812.0689) with 10-32 x 5/8" SCB screw (53.6515.0625.0). Step 15. At Head Covers, remove two screws as shown in Figure 6. Step 16. Install Front Mount (10.9812.0688) with two 8-32 x 5/8" SHCS screws (53.6696.0625.0). Step 17. Install Rear Handle (22.9812.0067 / 37498-20) by first looping lanyard around yoke arm and then threading into Rear Mount (Figure 7). Step 18. Thread Rotating Handle (22.9812.0069) into Controller Assembly (20.9812.0060 / 37498-10). Step 19. Install Controller Assembly by first looping lanyard around yoke arm and then threading into Front Mount. Rear Mount Front Mount Controller Assembly Cables Lanyard Lanyard Rotating Handle Rear Handle OR Note: The Rear Handle can be installed in one of two locations as shown. Figure 7: Installing Controller Assembly and Handles. 10 FOLLOWSPOT CONTROLLER USER MANUAL

Step 20. Connect Ethernet Cable and DC Power Cable to Controller Assembly (Figure 8). Ethernet Cable DC Power Cable Figure 8: Connecting Power and Data Cables FOLLOWSPOT CONTROLLER USER MANUAL 11

OPERATION Luminaire Configuration In order for the Followspot Controller to work with the luminaire, the following software version is required: + Bad Boy Spot Luminaire: v1.9fsc or greater For compatibility with all current functionality listed in this manual, v2.13 is required. In addition, the mechanisms (i.e., intensity, iris, edge, and zoom) need to be enabled for followspot control using the luminaire menu system. Enabling Followspot Control on Bad Boy Luminaires The Pan/Tilt menu provides a FOLLOW SPOT panel. This panel displays which mechanisms are currently enabled for followspot control (e.g., "intensity," "zoom/iris," "all," "none," etc.) Pressing FOLLOW SPOT brings up the Follow Spot menu. This menu is used to specify which mechanisms (of the four available) are controlled by a Followspot Controller, which will override DMX control on those mechanisms. + Intensity / Iris / Edge / Zoom - press to bring up on/off options. + ALL - enables all four mechanisms. + None - disables all four mechanisms. + Lefty Mode - inverts the FSC display to allow it to be used upside down. It also inverts the direction of the intensity fader to work upside down. + Intensity Scaling - allows the intensity specified by the Followspot Controller to be scaled by the DMX coming into the fixture. If enabled, the intensity value shown on the FSC display will be scaled by the percentage specified in the fixture s incoming DMX intensity slot. For example, if the intensity is set to 80% on the FSC, but the incoming DMX specifies 50% intensity, the resulting output from the fixture will be 40%. 12 FOLLOWSPOT CONTROLLER USER MANUAL

When any or all mechanisms are enabled for followspot control, "FSC Active" will be displayed in the Comm menu. The DMX channels associated with the active FSC mechanism(s) will be highlighted in yellow to indicate that those values come directly from the Followspot Controller and are not DMX-controlled. When any mechanism has been enabled for followspot control, pan and tilt will automatically become free. Pan and tilt will remain free until Followspot mode is turned off (all mechanisms deselected). At that time, upon exiting the Pan/ Tilt menu, pan and tilt will recalibrate (unless pan/tilt mode is changed to free or locked before exiting the Pan/Tilt menu). When pan and tilt are in Free mode due to followspot mechanisms being activated, Pan & Tilt follow will be displayed in the CONFIG panel on the main menu. Note that the Followspot Controller device does not need to be connected in order to enable followspot control on the luminaire. If there is no FSC connected while in Followspot mode, the selected mechanisms will simply ignore DMX until Followspot mode is exited. Note: The FSC will control the selected mechanisms whether or not DMX is present on the attached fixture. FOLLOWSPOT CONTROLLER USER MANUAL 13

Power Up The Followspot Controller will turn on when the luminaire is powered up. After briefly displaying a boot-up screen, the unit will display the control screen as shown below: INTEN EDGE NO DMX 0 IRIS 0 0 ZOOM 0 NO LINK When the data comm is established between the luminaire and the Followspot Controller, the unit will display "Linked" in the bottom right corner: INTEN EDGE NO DMX 0 IRIS 0 0 ZOOM 0 Linked Indicators No DMX - no incoming DMX512 is present on the attached luminaire. No Link - the Ethernet cable is either missing or not connected to anything Linked - an Ethernet link has been established between the FSC and another device. Intensity Flashing - when the intensity section flashes, it is an indication that the attached luminaire s incoming DMX512 shows a non-zero value on the strobe channel (which can affect the intensity if the strobe is closed or otherwise moved into the beam by the desk operator). Adjusting Parameters To adjust the intensity, edge, iris, and zoom, move the associated dial. (Refer to "Controls" on page 5.) The percentage setting will be reflected in the display as a number between 0 (off) and 100 (full). INTEN 100 EDGE NO DMX IRIS 52 23 ZOOM 0 Linked 14 FOLLOWSPOT CONTROLLER USER MANUAL

DMX Command Channels The luminaire s DMX control channel map includes commands for followspot functionality. These correspond to DMX values 134-149 as shown in the table below. Note: All values must be held for a minimum of 3 seconds to take effect. Table 1: Bad Boy Spot DMX Control Channels DMX Values (0-255) Function Notes 10 Recalibrate: All 11 Recalibrate: Erred Mechanisms 12 Recalibrate: Zoom/Edge 14 Recalibrate: Color 16 Recalibrate: Gobos 18 Recalibrate: Dimmer/Strobe/Iris 19 Recalibrate: Pan/Tilt 20 Lamp: Douse 30 Lamp: Start 40 Lamp Power Limit Select: 1400W default 45 Lamp Power Limit Select: 1200W 50 Lamp Power Limit Select: 900W 55 Lamp: Override Start-Up Power Limit Overrides default setting: 3 minute warm-up at 1200W or less. 60 Zoom Table Select: 30 Throw default 62 Zoom Table Select: 50 Throw 64 Zoom Table Select: 75 Throw 66 Zoom Table Select: 100 Throw 68 Zoom Table Select: 300 Throw 70 Zoom Table Select: 15 Throw 75 Zoom Speed Select: Maintain Focus default 77 Zoom Speed Select: Move Fast 80 Gobo: Set Zero Position 90 Display: Turn Backlight ON 95 Display: Turn Backlight OFF 100 Pan: Lock 102 Pan: Unlock 104 Tilt: Lock 106 Tilt: Unlock 108 Pan/Tilt: Free Motion 110 Pan/Tilt: Free Lock 112 Pan/Tilt: End Free Motion Zoom Tables maintain sharp focus on an image throughout the zoom range. Allows adjustment of the gobo wheel home position. FOLLOWSPOT CONTROLLER USER MANUAL 15

Table 1: Bad Boy Spot DMX Control Channels (Continued) DMX Values (0-255) Function Notes 120 Clear Logs 122 Invert Pan 124 Don t Invert Pan 126 Invert Tilt 128 Don t Invert Tilt 130 Swap Pan/Tilt 132 Don t Swap Pan/Tilt 134 Followspot: Intensity/Iris 135 Followspot: Intensity/Iris/Edge 136 Followspot: Intensity/Iris/Edge/Zoom 137 Followspot: Intensity/Iris/Zoom 138 End Followspot Mode 139 Followspot: Intensity 140 Followspot: Intensity/Edge 141 Followspot: Intensity/Edge/Zoom 142 Followspot: Intensity/Zoom 143 Followspot: Iris 144 Followspot: Iris/Edge 145 Followspot: Iris/Zoom 146 Followspot: Iris/Edge/Zoom 147 Followspot: Edge 148 Followspot: Edge/Zoom 149 Followspot: Zoom 150 Followspot: Turn intensity scaling ON 152 Followspot: Turn intensity scaling OFF FOLLOWSPOT CONTROL 16 FOLLOWSPOT CONTROLLER USER MANUAL

Updating FSC Software The Followspot Controller software can be updated as necessary. Updating the FSC software is similar to updating the software of a PRG luminaire except it can only be done over Ethernet (not DMX) and there is a specific FSC loader package. To update FSC software: Step 1. Connect Ethernet cable between computer and FSC. Step 2. Open FSCLoader.jar. Step Step Step Step 3. If computer has more than one Ethernet interface available, select appropriate network interface from dropdown menu. 4. Click Start Download button. FSC screen will change to bootloader screen and show load progress. 5. Wait for download to complete. 6. After download, FSC screen will briefly show new software version on splash screen, then revert to normal user display. FOLLOWSPOT CONTROLLER USER MANUAL 17

TROUBLESHOOTING Troubleshooting Guide The following table provides a list of common problems and possible solutions. Symptom Solution(s) Refer to... No DMX Ensure FSC Ethernet Cable is properly connected. page 7 Ensure luminaire is receiving DMX. --- No power Ensure FSC Power Cable is properly connected. page 7 Ensure luminaire is powered up. --- No control Ensure luminaire has the required software version. page 12 Ensure luminaire is set to Followspot (Free) mode. page 12 Intensity section of FSC display is flashing Check the luminaire s incoming DMX commands. If it shows a non-zero value on the strobe channel, then it can affect the intensity if the strobe is closed or otherwise moved into the beam by the desk operator. --- 18 FOLLOWSPOT CONTROLLER USER MANUAL

SPECIFICATIONS Technical Specifications 2.39 5.68 4.95 9.45 2.39 1.77 3.25 Figure 9: Followspot Controller Dimensions FOLLOWSPOT CONTROLLER USER MANUAL 19

Notes 20 FOLLOWSPOT CONTROLLER USER MANUAL

Followspot Controller User Manual Version as of: March 23, 2015 PRG part number: 02.9812.0060

Production Resource Group, LLC Dallas Office 8617 Ambassador Row, Suite 120 Dallas, Texas 75247 www.prg.com