OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas

Similar documents
Attachment to Certificate IECEx PTB X

OPTIWAVE 7300 C Supplementary instructions

Power supply. Calibration. Surface finishing. Seal. Process connection

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

IECEx Certificate of Conformity Annexe

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

ATEX Installation Drawings and Instructions

Installation guide 971 SmartRadar LTi

SET Installation and Operating Instructions. Level switch for two sensors

Signal converter for electromagnetic flowmeters

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

DPharp Differential Pressure and Pressure Transmitters

Installation & Operating Manual. iwap202

INSTRUCTION MANUAL (ATEX / IECEx)

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

MFC 300 Handbook. Signal converter for mass flowmeters. Electronic Revision: ER 3.3.xx (SW.REV. 3.3x)

Installation guide 877 FDI Field Display & Interface

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Temperature Input Module for Zone 1 Series 9482/32

Safety Instructions Proline Promass 300

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Intrinsic Safety Control Drawing

PRetrans Table of contents

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33

Signal converter for electromagnetic flowmeters

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Operating Manual. isolate501

MFC 400 Technical Datasheet

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

OPTITEMP TT 10 C/R Technical Datasheet

OPTIMASS 1000 Technical Datasheet

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Installation guide 970, 971 and 973 series SmartRadar

Introduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy

Field indicator for current loops with HART communication Models DIH50, DIH52

MFC 400 Technical Datasheet

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Installation guide 970 SmartRadar ATi

Safety Instructions Proline Promag 500

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

MFC 400 Technical Datasheet

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

ProcessMaster / HygienicMaster

Installation guide 854 XTG Level Gauge

Safety Instructions Nivotester FTC625, FTC325

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

User's Manual Model SE14 Magnetic Flow Converter

MFC 300 Technical Datasheet

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Emerson (Appleton Group ATX)

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Design and applications

LF Conductivity Measuring Probe

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Inductive sensor slot-type SI2-K08-AP7

SALES SERVICE +358 (0)

Description of equipment

Trimod Besta Level Switch type I 8 / IE9 8

SCS-400. Sealed Parcel Delivery System. Installation Manual

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

Two-channel safety barriers Series 9002

Page 1 of 5 Attachment to IECEx TUN X Issue 0

ProcessMaster, HygienicMaster FEX300, FEX500

Proline Promass 83, 84

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

Two-channel safety barriers Series 9002

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

MFC 400 Technical Datasheet

Remote I/O. 74 Remote I/O. Remote I/O System

CERTIFICATE OF COMPLIANCE

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Transcription:

OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas 1000 Series Twin Straight Tube Coriolis Mass Flowmeter 2000 Series Twin Straight Tube Coriolis Mass Flowmeter 3000 Series Single Z Tube Coriolis Mass Flowmeter 00 Series Twin U Tube Coriolis Mass Flowmeter 7000 Series Single Straight Tube Coriolis Mass Flowmeter 8000k Series Twin U Tube Coriolis Mass Flowmeter 8000/9000 Series Twin U Tube Coriolis Mass Flowmeter OPTIGAS 00 OPTIGAS 5000 MFC 300 Mass Flow Converter

CONTENTS OPTIMASS 1. Introduction 1.1 General..................................................................5 1.2 MFC 300F & MFC 300F T6...................................................6 1.3 OPTIMASS 1000 / 1010C / 1300C.............................................7 1.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6.....................................8 1.5 OPTIMASS 2000 / 2010C / 2300C.............................................9 1.6 OPTIMASS 3000 / 3010C / 3300C.............................................10 1.7 OPTIMASS / OPTIGAS 00 / 10C...........................................11 1.8 OPTIGAS 5000 / 5010C / 5300C...............................................12 1.9 OPTIMASS 7000 / 7010C / 7300C.............................................13 1.10 OPTIMASS 8000k / 8010kC / 8300kC.........................................14 1.11 OPTIMASS 8000 / 8010C / 8300C / 9000 / 9010C...............................15 1.12 Data Plates..............................................................16 2. Temperature limits 2.1 General..................................................................17 2.2 MFC 300F & MFC 300F T6...................................................17 2.3 OPTIMASS 1000 / 1010C / 1300C.............................................18 2.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6.....................................19 2.5 OPTIMASS 2000 / 2010C....................................................21 2.6 OPTIMASS 3000 / 3010C / 3300C 7000 / 7010C / 7300C..........................22 2.7 OPTIMASS 00 / 10C / OPTIGAS 00 / 10C...............................24 2.8 OPTIMASS 8000k / 8010kC / 8300kC..........................................24 2.9 OPTIMASS 8000 / 8010C / 8300C.............................................26 2.10 OPTIMASS 9000 / 9010C...................................................27 2.11 OPTIGAS 5000 / 5010C / 5300C..............................................27 2.12 Painted options...........................................................28 3. Connection of separated systems 3.1 General..................................................................29 3.2 Cable parameters.........................................................29 3.3 Equipotential bonding......................................................29 3.4 Terminal diagrams........................................................30 4. Electrical connections 4.1 General..................................................................31 4.2 Non-Ex I signal I/O connections..............................................32 4.3 Ex i signal I/O connections..................................................34 5. Service and maintenance 5.1 Maintenance..............................................................36 5.2 Replacement of mains fuse.................................................36 5.3 Returning the device for service or repair.....................................36 Appendix 1...................................................................37 2

Explanation of Symbols Used The following is a guide to the meaning of the symbols used in this handbook.the symbols fall into two types. The rectangular symbols with blue background draw the reader s attention to general points of information. The triangular symbols with yellow background draw the reader s attention to hazards or hazardous situations. General Information Information is important to the installation/operation of the meter. General Warning Risk of damage to the meter or installation. EX - Hazardous Area Warning Instruction MUST be observed in order to comply with Hazardous Areas Certification. High Voltage Risk of electric shock. General Hazard Non specific hazard that could result in injury. Hot Surface or High Temperature Risk of burning. Heavy Item Risk of injury. Do not install, operate or maintain this device without reading, understanding and following the factory supplied handbook. Failure to do so, may result in injury or damage. Read these instructions carefully before starting installation and save them for future reference. Observe all warnings and instructions marked on the device. You MUST only use a power supply that has a protective earth. Do not use the device with the covers removed! You MUST follow the installation instructions in the handbook, paying particular attention to: Handling Lifting Supporting and fixing the meter Cabling and connections. If the product does not operate normally, refer to the handbook or consult a qualified KROHNE service engineer. There are no operator-serviceable parts inside the product. 3

These terms may appear in this manual or on the device: Warning statement: Identify conditions or practice that could result in injury or loss of life. or Caution statement: Identify conditions or practice that could result in damage to the instrument or other property. Disclaimer: This document contains important information on the device. KROHNE attempts to be as accurate and up-to-date as possible but assumes no responsibility for errors or omissions. Nor does KROHNE make any commitment to update the information contained herein. This manual and all other documents are subject to change without prior notice. KROHNE will not be liable for any damage of any kind by using this device, including, but not limited to: direct; indirect; incidental; punitive and consequential damages. Any device purchased from KROHNE is warranted in accordance with the relevant product documentation and our Terms and Conditions of Sale. KROHNE reserves the right to alter the content of its documents, including this disclaimer in any way, at any time, for any reason, without prior notification and will not be liable in any way for possible consequences of such changes. Product liability and Warranty Responsibility for suitability and intended use of this device rests solely with the user. Improper installation and operation of the device may lead to loss of warranty. In addition, the Terms and Conditions of Sale are applicable and are the basis for the purchase contract. If a device needs to be returned to KROHNE, please note the information given at the back of the Handbook. KROHNE regrets that they cannot repair or service a device unless accompanied by the completed form This instrument has been developed and manufactured by: KROHNE Ltd Rutherford Drive Park Farm Industrial Estate Wellingborough Northants NN8 6AE United Kingdom For information, maintenance or service, please contact your nearest local KROHNE representative. See www.krohne.com WARNING No changes may be made to the devices. Unauthorized changes might affect the explosion safety of the devices. Be sure to follow these instructions! IMPORTANT The prescriptions, regulations and electrical data described in the EC type examination certificate MUST be obeyed. In addition to the general regulations for low-voltage installations (e.g.hd384) the regulations laid down in the standard for electrical installations in gas hazardous areas (e.g. IEC/EN 60079-14) or dust hazardous areas (e.g. IEC/EN 61241-14) MUST be complied with. Installation, commissioning, utilization and maintenance must be carried out only by personnel trained in explosion safety. This manual must be read in conjunction with the OPTIMASS / OPTIGAS Handbooks. 4

1 INTRODUCTION OPTIMASS 1.1 General The OPTIMASS / OPTIGAS flowmeter systems consist of a mass flow sensor and a mass flow converter or a mass flow sensor and associated apparatus. The separate mass flow sensor with a mass flow converter is identified as: OPTIMASS 1000 flow sensor with MFC 300 F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS 1000 T6 flow sensor with MFC 300F T6 flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS 2000 flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS 3000 flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS / OPTIGAS 00 flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS 7000 flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS 8000k flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIMASS 8000/9000 flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X OPTIGAS 5000 flow sensor with MFC 300F flow converter; see PTB 06 ATEX 2036 X with PTB 06 ATEX 2038 X The separate flowmeter with associated apparatus is identified as: OPTIMASS 1010C; see PTB 06 ATEX 2036 X OPTIMASS 1010C T6; see PTB 06 ATEX 2036 X OPTIMASS 2010C; see PTB 06 ATEX 2036 X OPTIMASS 3010C; see PTB 06 ATEX 2036 X OPTIMASS / OPTIGAS 10C; see PTB 06 ATEX 2036 X OPTIMASS 7010C; see PTB 06 ATEX 2036 X OPTIMASS 8010kC; see PTB 06 ATEX 2036 X OPTIMASS 8010C/9010C; see PTB 06 ATEX 2036 X OPTIGAS 5010C; see PTB 06 ATEX 2036 X The flowmeter in a compact configuration is identified as: OPTIMASS 1300C (OPTIMASS 1000 + MFC300 ); see PTB 06 ATEX 2037 X OPTIMASS 1300C T6 (OPTIMASS 1000 T6 + MFC300 T6); see PTB 06 ATEX 2037 X OPTIMASS 2300C (OPTIMASS 2000 + MFC300 ); see PTB 06 ATEX 2037 X OPTIMASS 3300C (OPTIMASS 3000 + MFC300 ); see PTB 06 ATEX 2037 X OPTIMASS 7300C (OPTIMASS 7000 + MFC300 ); see PTB 06 ATEX 2037 X OPTIMASS 8300kC (OPTIMASS 8000k + MFC300 ); see PTB 06 ATEX 2037 X OPTIMASS 8300C (OPTIMASS 8000 + MFC300 ); see PTB 06 ATEX 2037 X OPTIGAS 5300 C (OPTIGAS 5000 + MFC300 ); see PTB 06 ATEX 2037 X Note that the OPTIMASS 9000 is not available in a compact configuration.all OPTIMASS sensors (separate and compact) and converters are available with a painted finish for aggressive environments. For these meters, the model name has the suffix -Painted Example: OPTIMASS 1000-Painted The output configuration of the MFC300 is described by the CG32.XYZ number listed on the data label. See section 4 for a detailed description. All types are intended for use in Zone 1 Category 2.All types (except OPTIMASS 3000/3010C/3300C and OPTIGAS 5000/5010C/5300C) are also intended for Zone 0 Category 1 areas. Refer to the Ex markings table for each meter. In addition, certain versions of MFC300 have intrinsically safe signal outputs suitable for use in Category 1 areas. 5

1.2 MFC 300F & MFC 300F T6 The MFC 300F & MFC 300F T6 have intrinsically safe connections to the mass flow sensor with either increased safety or intrinsically safe signal outputs. The signal output connection compartment can be configured with protection type Ex d or Ex e. The marking is as follows: For Ex i outputs II 2(1) G Ex d [ia/ib] IIC T6 Gb II 2(1) D Ex ib t [ia Da] IIIC T80 C Db For non-ex i outputs II 2 G Ex d [ib] IIC T6 Gb II 2 D Ex ib t IIIC T80 C Db II 2(1) G Ex de [ia/ib] IIC T6 Gb II 2(1) D Ex ib t [ia Da] IIIC T80 C Db II 2 G Ex de [ib] IIC T6 Gb II 2 D Ex ib t IIIC T80 C Db The output connections to the mass flow sensor have the following values: Power Supply Circuit Data Circuit MFC 300F MFC 300F T6 MFC 300F / MFC 300F T6 Uo = 16.5 V Uo = 16.5 V Uo = 6 V Io = 305 ma Io = 262 ma Io = 33 ma Po = 1.25 W Po = 1.07 W Po = 120 mw Characteristic curve: linear Co = 230 nf Co = 2 nf Co = 1.9 μf Lo = 320 μh Lo = 450 μh Lo = 2 mh For details of the signal output values, compare the table in section 4 with the CG32.XYZ number listed on the data label. 6

1.3 OPTIMASS 1000 / 1010C / 1300C The OPTIMASS 1000 / 1010C mass flow sensor / mass flow meter is designed with intrinsically safe protection type. The marking for the OPTIMASS 1000 / 1010C for versions with or without heating jacket / insulation is as follows: II 1/2 G Ex ib IIC T4...T1 Ga/Gb II 2 D Ex ib IIIC T175 C Db The input connections to the OPTIMASS 1010C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Ii = ma Pi = 1.3W Pi = 120mW Ci = 35nF Ci = 35nF Li = 10uH Li = 10uH The marking for the compact OPTIMASS 1300C is as follows: For non-ex i signal outputs without heating jacket / insulation II 1/2 G Ex d [ib] IIC T4...T1 Ga/Gb II 1/2 G Ex de [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T185 C Db II 2 D Ex t IIIC T185 C Db For non-ex i signal outputs with heating jacket / insulation II 1/2 G Ex d [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T195 C Db II 1/2 G Ex de [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T195 C Db For Ex i signal outputs without heating jacket / insulation II 1/2(1) G Ex d [ia/ib] IIC T4...T1 Ga/Gb II 1/2(1) G Ex de [ia/ib] IIC T4...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T185 C Db II 2(1) D Ex t [ia Da] IIIC T185 C Db For Ex i signal outputs with heating jacket / insulation II 1/2(1) G Ex d [ia/ib] IIC T4...T1 Ga/Gb II 1/2(1) G Ex de [ia/ib] IIC T4...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T195 C Db II 2(1) D Ex t [ia Da] IIIC T195 C Db 7

1.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6 The OPTIMASS 1000 T6 / 1010C T6 mass flow sensor / mass flow meter is designed with intrinsically safe protection type. The marking for the OPTIMASS 1000 / 1010C T6 for versions with or without heating jacket / insulation is as follows: II 1/2 G Ex ib IIC T6...T1 Ga/Gb II 2 D Ex ib IIIC T165 C Db The input connections to the OPTIMASS 1010C T6 for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 265mA Ii = ma Pi = 1.1W Pi = 120mW Ci = 35nF Ci = 35nF Li = 10uH Li = 10uH The marking for the compact OPTIMASS 1300C T6 is as follows: For non-ex i signal outputs without heating jacket / insulation II 1/2 G Ex d [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T160 C Db II 1/2 G Ex de [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T160 C Db For non-ex i signal outputs with heating jacket / insulation II 1/2 G Ex d [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T165 C Db II 1/2 G Ex de [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T165 C Db For Ex i signal outputs without heating jacket / insulation II 1/2(1) G Ex d [ia/ib] IIC T6...T1 Ga/Gb II 1/2(1) G Ex de [ia/ib] IIC T6...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T160 C Db II 2(1) D Ex t [ia Da] IIIC T160 C Db For Ex i signal outputs with heating jacket / insulation II 1/2(1) G Ex d [ia/ib] IIC T6...T1 Ga/Gb II 1/2(1) G Ex de [ia/ib] IIC T6...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T165 C Db II 2(1) D Ex t [ia Da] IIIC T165 C Db 8

1.5 OPTIMASS 2000 / 2010C / 2300C The OPTIMASS 2000 / 2010C mass flow sensors / mass flow meters are designed with intrinsically safe protection type. The marking for the OPTIMASS 2000 / 2010C is as follows: II 1/2 G Ex ib IIC T6...T1 Ga/Gb II 2 D Ex ib IIIC T150 C Db The input connections to the OPTIMASS 2010C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Ii = ma Pi = 1.3W Pi = 120mW Ci = 35nF Ci = 35nF Li = 10uH Li = 10uH The marking for the compact OPTIMASS 2300C is as follows: For non-ex i signal outputs II 1/2 G Ex d [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T160 C Db II 1/2 G Ex de [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T160 C Db For Ex i signal outputs II 1/2(1) G Ex d [ia/ib] IIC T6...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T160 C Db II 1/2(1) G Ex de [ia/ib] IIC T6...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T160 C Db 9

1.6 OPTIMASS 3000 / 3010C / 3300C The OPTIMASS 3000 / 3010C mass flow sensors / mass flow meters are designed with intrinsically safe protection type. The marking for the OPTIMASS 3000 / 3010C is as follows: No heating jacket / insulation II 2 G Ex ib IIC T6...T1 Gb II 2 D Ex ib IIIC T150 C Db Heating jacket / insulation II 2 G Ex ib IIC T6...T1 Gb II 2 D Ex ib IIIC T165 C Db The input connections to the OPTIMASS 3010C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Pi = 1.3W Ci = 35nF Li = 10uH Ii = ma Pi = 120mW Ci = 35nF Li = 10uH The marking for the compact OPTIMASS 3300C is as follows: For non-ex i signal outputs without heating jacket / insulation II 2 G Ex d [ib] IIC T6...T1 Gb II 2 D Ex t IIIC T160 C Db II 2 G Ex de [ib] IIC T6...T1 Gb II 2 D Ex t IIIC T160 C Db For non-ex i signal outputs with heating jacket / insulation II 2 G Ex d [ib] IIC T6...T1 Gb II 2 D Ex t IIIC T170 C Db II 2 G Ex de [ib] IIC T6...T1 Gb II 2 D Ex t IIIC T170 C Db For Ex i signal outputs without heating jacket / insulation II 2(1) G Ex d [ia/ib] IIC T6...T1 Gb II 2(1) G Ex de [ia/ib] IIC T6...T1 Gb II 2(1) D Ex t [ia Da] IIIC T160 C Db II 2(1) D Ex t [ia Da] IIIC T160 C Db For Ex i signal outputs with heating jacket / insulation II 2(1) G Ex d [ia/ib] IIC T6...T1 Gb II 2(1) G Ex de [ia/ib] IIC T6...T1 Gb II 2(1) D Ex t [ia Da] IIIC T170 C Db II 2(1) D Ex t [ia Da] IIIC T170 C Db 10

1.7 OPTIMASS 00 / 10C / OPTIGAS 00 / 10C The OPTIMASS 00 / 10C OPTIGAS 00 / 10C mass flow sensors / mass flow meters are designed with intrinsically safe protection type. The marking for the OPTIMASS 00 / 10C / OPTIGAS 00 / 10C is as follows: II 1/2 G Ex ib IIC T4...T1 Ga/Gb II 2 D Ex ib IIIC T210 C Db The input connections to the OPTIMASS 10C / OPTIGAS 10C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Pi = 1.3W Ci = 35nF Li = 10uH Ii = ma Pi = 120mW Ci = 35nF Li = 10uH 11

1.8 OPTIGAS 5000 / 5010C / 5300C The OPTIGAS 5000 / 5010C mass flow sensor / mass flow meter is designed with intrinsically safe protection type. The marking for the OPTIGAS 5000 / 5010C for versions with or without heating jacket / insulation is as follows: II 2 G Ex ib IIC T4...T1 Gb The input connections to the OPTIGAS 5010C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Pi = 1.3W Ci = 35nF Li = 10uH Ii = ma Pi = 120mW Ci = 35nF Li = 10uH The marking for the compact OPTIGAS 5300C is as follows: For non-ex i signal outputs II 2 G Ex d [ib] IIC T4...T1 Gb II 2 G Ex de [ib] IIC T4...T1 Gb For Ex i signal outputs II 2(1) G Ex d [ia/ib] IIC T4...T1 Gb II 2(1) G Ex de [ia/ib] IIC T4...T1 Gb 12

1.9 OPTIMASS 7000 / 7010C / 7300C The OPTIMASS 7000 / 7010C mass flow sensors / mass flow meters are designed with intrinsically safe protection type. The marking for the OPTIMASS 7000 / 7010 C is as follows: No heating jacket / insulation II 1/2 G Ex ib IIC T6...T1 Ga/Gb II 2 D Ex ib IIIC T150 C Db Heating jacket / insulation II 1/2 G Ex ib IIC T6...T1 Ga/Gb II 2 D Ex ib IIIC T165 C Db The input connections to the OPTIMASS 7010C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Pi = 1.3W Ci = 35nF Li = 10uH Ii = ma Pi = 120mW Ci = 35nF Li = 10uH The marking for the compact OPTIMASS 7300C is as follows: For non-ex i signal outputs without heating jacket / insulation II 1/2 G Ex d [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T160 C Db II 1/2 G Ex de [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T160 C Db For non-ex i signal outputs with heating jacket / insulation II 1/2 G Ex d [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T170 C Db II 1/2 G Ex de [ib] IIC T6...T1 Ga/Gb II 2 D Ex t IIIC T170 C Db For Ex i signal outputs without heating jacket / insulation II 1/2(1) G Ex d [ia/ib] IIC T6...T1 Ga/Gb II 1/2(1) G Ex de [ia/ib] IIC T6...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T160 C Db II 2(1) D Ex t [ia Da] IIIC T160 C Db For Ex i signal outputs with heating jacket / insulation II 1/2(1) G Ex d [ia/ib] IIC T6...T1 Ga/Gb II 1/2(1) G Ex de [ia/ib] IIC T6...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T170 C Db II 2(1) D Ex t [ia Da] IIIC T170 C Db 13

1.10 OPTIMASS 8000k / 8010kC / 8300kC The OPTIMASS 8000k / 8010kC mass flow sensors / mass flow meters are designed with intrinsically safe protection type. The marking for the OPTIMASS 8000k / 8010kC is as follows: II 1/2 G Ex ib IIC T4...T1 Ga/Gb II 2 D Ex ib IIIC T210 C Db The input connections to the OPTIMASS 8010kC / 8010kC for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Ii = ma Pi = 1.3W Pi = 120mW Ci = 35nF Ci = 35nF Li = 10uH Li = 10uH The marking for the compact OPTIMASS 8300kC is as follows:: For non-ex i signal outputs II 1/2 G Ex d [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T265 C Db For Ex i signal outputs II 1/2(1) G Ex d [ia/ib] IIC T4...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T265 C Db II 1/2 G Ex de [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T265 C Db II 1/2(1) G Ex de [ia/ib] IIC T4...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T265 C Db 14

1.11 OPTIMASS 8000 / 8010C / 8300C / 9000 / 9010C The OPTIMASS 8000 / 8010C and OPTIMASS 9000 / 9010C mass flow sensors / mass flow meters are designed with intrinsically safe protection type. The marking for the OPTIMASS 8000 / 8010C is as follows: II 1/2 G Ex ib IIC T4...T1 Ga/Gb II 2 D Ex ib IIIC T280 C Db The marking for the OPTIMASS 9000 / 9010C is as follows: II 1/2 G Ex ib IIC T4...T1 Ga/Gb II 2 D Ex ib IIIC T385 C Db The input connections to the OPTIMASS 8010 / 9010C for use with associated apparatus have the following maximum values: Power Supply Circuit Data Circuit Ui = 16.5V Ui = 11.8V Ii = 3mA Pi = 1.3W Ci = 35nF Li = 10uH Ii = ma Pi = 120mW Ci = 35nF Li = 10uH The marking for the compact OPTIMASS 8300C is as follows: For non-ex i signal outputs II 1/2 G Ex d [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T275 C Db II 1/2 G Ex de [ib] IIC T4...T1 Ga/Gb II 2 D Ex t IIIC T275 C Db For Ex i signal outputs II 1/2(1) G Ex d [ia/ib] IIC T4...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T275 C Db II 1/2(1) G Ex de [ia/ib] IIC T4...T1 Ga/Gb II 2(1) D Ex t [ia Da] IIIC T275 C Db 15

1.12 Data Plates The data plate on the connection box of separate mass flow sensors typically contains the following information: 9 1 2 3 4 8 7 5 6 1 Company logo and address 2 Model/size 3 Year of Manufacture 4 Serial Number 5 Handbook Publication Number 6 Identification Number of the notified body, as required by Directive 94/95 EC, Annex IV 7 Ex Specific Requirements (example shown) 8 Certificate Number 9 Ex Marking (Example Shown) 1 2 3 4 5 0 9 8 7 6 1 Company Logo and Address 2 Model/size 3 Date of Manufacture 4 Serial Number 5 Handbook Publication Number 6 Power Supply Data 7 Ex Specific Requirements 8 Certificate Number 9 Ex Marking (Example Shown) 0 Identification Number of the notified body, as required by Directive 94/95 EC, Annex IV 16

2 TEMPERATURE LIMITS 2.1 General OPTIMASS Due to the influence of the media temperature, mass flow sensors and compact mass flow meters are not allocated to any fixed temperature class. For allocation regarding the non-insulated and heated/insulated versions, please refer to the tables below. The temperature limits below apply under the following conditions: The flowmeter is installed and operated in accordance with the installation directions given in the Installation and Operating Instructions. The flowmeter is not heated up by any additional heat radiation (direct solar radiation, heat from adjacent plant parts) so causing it to operate above the permissible ambient temperature range. Insulation is not hindering free ventilation of the mass flow converter housing. 2.2 MFC 300F & MFC 300F T6 The MFC 300F mass flow converter is suitable for temperature classes T6.T1 with a Max Surface Temperature T80 C. w ith the following restictions on ambient temperature: 1 Aluminium converter housing: I/O options listed in the table below: Tamb: - C...+65 C I/O options not listed in the table below: Tamb - C...+60 C 2 Stainless steel converter housing: Tamb: - C...+55 C IO Configuration (last three characters) Designation 100 Basic IO 488, 4C8 to 4K8 688, 6C8 to 6K8 788, 7C8 to 7K8 888, 8C8 to 8K8 B88, BC8 to BK8 C88, CC8 to CK8 D88 to DP8 E88 to EP8 F80, FCO to FKO G88 to GP8 GCC to GKC, GCE to GKC GCF to GKF HCC to HKC, HCE to HKC HCF to HKF 200 300 Exi IO Modular IO and Module Carrier with 1 module pulse / status or control in Modular IO and Module Carrier with 1 module pulse / status Profibus PA or Foundation Fieldbus and Module Carrier with 1 module (all modules) Profibus DP and Module Carrier with 1 module Pulse / Status or Control In MODBUS IO and Module Carrier with 1 module (all modules) Modbus IO and Module Carrier with 2 module pulse / status or control in 17

2.3 OPTIMASS 1000 / 1010C / 1300C The OPTIMASS 1000 / 1010C / 1300C is suitable for temperature classes T4.T1 according to the following tables: OPTIMASS 1000 / 1010C with or without heating jacket / insulation Ambient Temp. T amb C 65 Temperature Class 89 T4 T130 130 T3 T1 T175 OPTIMASS 1300C with aluminium converter housing and without heating jacket / insulation Ambient Temp. T amb C 50 Temperature Class 70 T4 T130 130 T3 T1 T185 60 60 T4 T1 T125 65* 65 T4 - T1 T130 OPTIMASS 1300C with aluminium converter housing and heating jacket / insulation Ambient Temp. T amb C 65 T4 T130 130 T3 T1 T195 50 65 T4 T130 100 T3 T1 T165 60 60 T4 T1 T125 65* 65 T4 T1 T130 OPTIMASS 1300C with stainless steel converter housing and without heating jacket / insulation Ambient Temp. T amb C 50 Temperature Class 70 T4 T130 130 T3 T1 T185 55 55 T4 T1 T120 OPTIMASS 1300C with stainless steel converter housing and heating jacket / insulation Ambient Temp. T amb C 65 T4 T130 120 T3 T1 T185 50 65 T4 T130 75 T3 T1 T1 55 55 T4 T1 T120 18 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a continuous minimum working temperature of 80 C.

2.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6 The OPTIMASS 1000 T6 / 1010C T6 / 1300C T6 is suitable for temperature classes T6.T1 according to the following table: OPTIMASS 1000 T6 / 1010C T6 with or without heating jacket / insulation Ambient Temp. T amb C 50 65 45 T6 T80 60 T5 T95 95 T4 T130 130 T3 T1 T165 60 T5 T95 95 T4 T130 130 T3 - T1 T165 95 T4 T130 130 T3 - T1 T165 OPTIMASS 1300C T6 with aluminium converter housing & without heating jacket / insulation Ambient Temp. T amb C 50 45 T6 T80 60 T5 T95 100 T4 T130 130 T3 T1 T155 60 T5 T95 100 T4 T130 130 T3 - T1 T160 60 60 T4 - T1 T95 65* 65 T4 - T1 T100 OPTIMASS 1300C T6 with aluminium converter housing & heating jacket / insulation Ambient Temp. T amb C 50 45 T6 T80 60 T5 T95 95 T4 T130 130 T3 T1 T165 60 T5 T95 95 T4 T130 100 T3 - T1 T135 60 60 T4 - T1 T95 65* 65 T4 - T1 T100 19

OPTIMASS 1300C T6 with stainless steel converter housing & without heating jacket / insulation Ambient Temp. T amb C 50 45 T6 T80 60 T5 T95 100 T4 T130 130 T3 T1 T155 60 T5 T95 100 T4 T130 130 T3 - T1 T160 55 55 T4 - T1 T95 OPTIMASS 1300 T6 with stainless steel converter housing and heating jacket / insulation Ambient Temp. T amb C 45 T6 T80 60 T5 T95 95 T4 T130 120 T3 T1 T155 50 60 T5 T95 75 T4 - T1 T110 55 55 T4 - T1 T130 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a minimum continuous working temperature of 80 C. 20

2.5 OPTIMASS 2000 / 2010C / 2300C The OPTIMASS 2000 / 2010C / 2300C are suitable for temperature classes T6.T1 according to the following tables: OPTIMASS 2000 / 2010C with or without heating jacket / insulation Ambient Temp. T amb C 65 65 T6 T80 75 T5 T95 110 T4 T130 130 T1-3 T150 75 T5 T95 110 T4 T130 130 T1-3 T150 OPTIMASS 2300C with aluminium converter housing, with or without heating jacket / insulation Ambient Temp. T amb C 50 50 T6 T80 65 T5 T95 100 T4 T130 130 T3 - T1 T160 65 T5 T95 100 T4 - T1 T130 60 60 T4 - T1 T90 65* 65 T4 - T1 T95 OPTIMASS 2300C with stainless steel converter housing, with or without heating jacket / insulation Ambient Temp. T amb C 50 T6 T80 65 T5 T95 100 T4 T130 120 T3 - T1 T150 50 65 T5 T95 75 T4 - T1 T105 55 55 T5 - T1 T85 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a continuous working temperature of 80 C. 21

2.6 OPTIMASS 3000 / 3010C / 3300C / 7000 / 7010C / 7300C The OPTIMASS 3000 / 3010C / 3300C and OPTIMASS 7000 / 7010C / 7300C are suitable for temperature classes T6.T1 according to the following tables: OPTIMASS 3000 / 3010C and 7000 / 7010 C without heating jacket / insulation Ambient Temp. T amb C 50 65 OPTIMASS 3000 / 3010C and 7000 / 7010C with heating jacket / insulation Ambient Temp. T amb C 65 OPTIMASS 3300C / 7300C with aluminium converter housing and without heating jacket / insulation Ambient Temp. T amb C 50 70 T6 T80 90 T5 T95 130 T4 T130 150 T3 T1 T150 70 T6 T80 85 T5 T95 130 T4 T130 150 T3 T1 T150 85 T5 T95 125 T4 T130 150 T3 T1 T150 65 T6 T80 80 T5 T95 115 T4 T130 150 T3 T1 T165 80 T5 T95 115 T4 T130 150 T3 T1 T165 55 T6 T80 75 T5 T95 120 T4 T130 150 T3 T1 T160 75 T5 T95 115 T4 T130 150 T3 T1 T160 60 60 T4 T1 T85 65* 65 T4 T1 T90 22

OPTIMASS 3300C / 7300C with aluminium converter housing and with heating jacket / insulation Ambient Temp. T amb C 55 T6 T80 70 T5 T95 100 T4 T125 145 T3 T1 T170 50 70 T5 T95 100 T4 T1 T125 60 60 T4 T1 T85 65* 65 T4 T1 T90 OPTIMASS 3300C / 7300C with stainless steel converter housing and without heating jacket / insulation Ambient Temp. T amb C 55 T6 T80 75 T5 T95 120 T4 T130 150 T3 T1 T160 75 T5 T95 50 115 T4 T130 135 T3 T1 T145 55 55 T4 T1 T80 OPTIMASS 3300C / 7300C with stainless steel converter housing and with heating jacket / insulation Ambient Temp. T amb C 55 T6 T80 70 T5 T95 100 T4 T125 145 T3 T1 T170 50 70 T5 T95 75 T4 T1 T100 55 55 T4 T1 T80 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a minimum continuous working temperature of 80 C. 23

2.7 OPTIMASS 00 / 10C / OPTIGAS 00 / 10C The OPTIMASS 00 / 10C / OPTIGAS 00C / 10C are suitable for temperature classes T4.T1 according to the following tables: OPTIMASS 00 / 10C and OPTIGAS 00 / 10C without heating jacket / insulation Ambient Temp. T amb C -...65 60 T4 T130 125 T3 T195 1 T2 T1 T210 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a continuous working temperature of 80 C. 2.8 OPTIMASS 8000k / 8010kC / 8300kC The OPTIMASS 8000k / 8010kC / 8300kC is suitable for temperature classes T4.T1 according to the following tables: OPTIMASS 8000k / 8010kC with or without heating jacket / insulation (min.process temp. - C) Ambient Temp. T amb C Temperature Class -...65 80 T4 T130 1 T3 T195 230 T2 - T1 T280 OPTIMASS 8000k / 8010kC with or without heating jacket / insulation. Cryogenic applications Ambient Temp. T amb C OPTIMASS 8300kC with aluminium converter housing and with or without heating jacket / insulation Ambient Temp. T amb C Temperature Class 60 T4 T125 -... -...50 Temperature Class -20...65-195...80 T4 - T1 T130 120 T3 T190 190 T2 - T1 T265 120 T3 T190 190 T2-T1 T260 -...55 55 T4-T1 T125 -...60* 60 T4-T1 T130 24

OPTIMASS 8300kC with stainless steel converter housing and with or without heating jacket / insulation. (min. process temp. - C) Ambient Temp. T amb C Temperature Class 60 T4 T125 -... -...45 120 T3 T195 190 T2 - T1 T265 55 T4 T125 190 T2-T1 T260 -...50* 50 T4-T1 T120 OPTIMASS 8300kC with stainless Steel converter housing and with / without heating jacket / insulation. (min. process temp. - C Ambient Temp. T amb C Temperature Class -25... -195...60 T4 - T1 T125 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a continuous minimum working temperature of 80 C. 25

2.9 OPTIMASS 8000 / 8010C / 8300C The OPTIMASS 8000 / 8010C / 8300C is suitable for temperature classes T4.T1 according to the following tables: OPTIMASS 8000 / 8010C with or without heating jacket / insulation Ambient Temp. T amb C 80 T4 T130 65 145 T3 T195 230 T2 T1 T280 OPTIMASS 8300C with aluminium converter housing and with or without heating jacket / insulation Ambient Temp. T amb C 45 T4 T130 110 T3 T195 190 T2 T1 T275 50 110 T3 T195 190 T2 T1 T275 60 60 T3 T1 T145 65* 65 T4 - T1 T150 OPTIMASS 8300C with stainless steel converter housing and with or without heating jacket / insulation Ambient Temp T amb C 45 T4 T130 110 T3 T195 190 T2 T1 T275 50 110 T3 T195 190 T2 T1 T275 55 55 T3 T1 T1 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a continuous working temperature of 80 C. 26

2.10 OPTIMASS 9000 / 9010C The OPTIMASS 9000 / 9010C is suitable for temperature classes T4.T1 according to the following tables: Ambient Temp. Tamb C 65 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a continuous working temperature of 80 C. 2.11 OPTIGAS 5000 / 5010C / 5300C The OPTIGAS 5000 / 5010C / 5300C is suitable for temperature classes T4.T1 according to the following tables: OPTIGAS 5000 / 5010C without heating jacket / insulation Ambient Temp. Tamb C 65 OPTIGAS 5300C with aluminium converter housing and without heating jacket / insulation Ambient Temp. Tamb C OPTIGAS 5300C with stainless steel converter housing and without heating jacket / insulation Ambient Temp. Tamb C OPTIMASS 9000 / 9010C with heating jacket / insulation temp.tm C temp. TM C temp TM C temp. TM C 70 T4 80 T4 95 T3 T1 T4 93 T3 T1 50 93 T3 T1 60 60 T3 T1 65* 65 T4 - T1 T4 93 T3 T1 50 70 T3 T1 55 55 T3 T1 95 T4 T130 160 T3 T195 255 T2 T290 350 T1 T385 * Only for equipment configurations according to the table in section 2.2 The cable supplied by KROHNE is designed for a continuous working temperature of up to 105 C. Alternative cabling must be a heat-resistant type with a minimum continuous working temperature of 80 C. 27

2.12 Painted options OPTIMASS 1000, 1010C, 1000 T6, 1010C T6, 1300C, 1300C T6, 2000, 2010C, 2300C, 3300C, 00, 10C, 7000, 7010C, 7300C, 8000k, 8010kC, 8300kC and OPTIGAS 00, 10C are available with a paint finish to prevent corrosion. Where the meter is remote, the MFC 300F / T6 is also available with a painted finish. The painted option is not available where the meter has a heated jacket or insulation. For painted meters, the maximum permissible ambient temperature Tamb is C and the maximum permissible medium temperature T m is 110 C (or lower as required by the temperature class). 28

3 CONNECTION OF SEPARATED SYSTEMS 3.1 General OPTIMASS In the case of separate systems, the sensor and converter are connected using 4 core 2 pair cable with an overall shield. Each cable pair carries an intrinsically safe circuit (Power Supply Circuit and Data Circuit). The maximum length of the connecting cable for functional reasons is 300m, provided that the capacitance and inductance of the cable does not exceed the limits specified in section 3.2 below. The requirements of IEC/EN 60079-14 should be adhered to when installing the flowmeter. 3.2 Cable Parameters The following points need be to be followed when selecting the connecting cable for separated systems: The maximum permitted total capacitance and inductance for the connecting cable is : C L = 195 nf L L = 310 μh Cable supplied by Krohne has the following parameters: C L < 200pF/m L L < 0.7μH/m The cable selected must have a temperature rating equal to or better than the maximum range of temperatures present in the installation taking into account temperature gradients on the flow sensors (see the notes in section 2). The cable must be capable of withstanding a test voltage of 1000V AC and have a minimum insulation thickness of 0.2mm, as per IEC/EN60079-14 clause 12.2.2.7. 3.3 Equipotential bonding The MFC 300F mass flow converter or OPTIMASS / OPTIGAS x300c mass flow meter must be included in the equipotential bonding system of the installation using the equipotential bonding terminal on the mass flow converter housing wall bracket or mass flow meter housing mounting stem respectively. In separated systems the intrinsically safe power supply and data circuits are galvanically isolated from earth, therefore, an equilisation cable between the mass flow sensor and mass flow converter should not be used. Where screened cable is used, the screen should only be earthed at the mass flow sensor end. In the special case of a screen being earthed at both ends of the system, a potential difference between the sensor and converter is not permitted. Refer to IEC/EN 60079-14 clause 12.2.2.3 for further requirements for cable screens. 29

3.4 Terminal Connections 1 2 S B A - + - + 12V BA 1 MFC 300F Mass flow converter junction box 2 OPTIMASS / OPTIGAS Mass flow sensor junction box MFC 300F Mass flow converter junction box The Power Supply Circuit is connected to terminals + and and the Data Circuit is connected to terminals A and B. The other terminals should not be used. OPTIMASS / OPTIGAS Mass flow sensor junction box The Power Supply Circuit is connected to terminals + and and the Data Circuit is connected to terminals A and B. The other terminals should not be used. The jumper connection determines the termination resistor for the Data Circuit. Screening: Please see the illustrations above and refer to section 3.3. 30

4 ELECTRICAL CONNECTIONS OPTIMASS 4.1 General The MFC 300F mass flow converter or OPTIMASS / OPTIGAS x300c mass flow meter must be included in the equipotential bonding system of the installation using the equipotential bonding terminal on the mass flow converter housing wall bracket or mass flow meter housing mounting stem respectively. The covers of the housing electronics compartment and the housing itself are provided with a "flameproof" thread. The f "flameproof" thread is a tight fit due to explosion proof requirements. Screw the cover on or off with care and never use excessive force! Keep the threads free of dirt and apply Teflon grease (eg. NONTRIBOS type Li EP2). The grease will help to prevent the threads from locking due to corrosion To open the covers, remove the hexagonal "retention" lock using a No. 3 Allen key. After closing the covers, refit the "retention lock". Electronics compartment: Allow the electronics to de-energize before opening the electronics compartment: T6: at least 35 min., T5: at least 10 min. Terminal compartment: The terminal compartment can be opened in hazardous areas, for a short period of time (eg. to check wiring configuration) with the power supply connected, where: a) the terminal compartment has an ignition protection type increased safety (standard) and b) the I/O circuits have an ignition protection type intrinsic safety and c) the cover for the power supply terminals (L,N) is closed (see illustration) Work on I/O terminals A-D can be carried out with the power supply connected, provided that the regulations on intrisically safe circuits are followed As soon as the work has been completed, the cover must be replaced and the retention lock re-fitted. 1 2 N L A A- A+ B B- C C- D D- 1 Electrical Connections 2 I/O Connections Terminal L, N L+, L- A, A-,A+ B, B- C, C- D, D- Function, electrical data Connection for mains, always non-ex i 100..230 VAC, +10%/-15%, 22 VA 12..24 V DC, +30%/-25%, 12 W 24 VAC, +10%/-15%, 22VA 24 VDC, +30%/-25%, 12W Um = 253 V Connection for signal I/Os (PELV circuits), non-ex I or Ex I, are dependent on specific version of the MFC300 converter ordered. Consult the table with CG32 numbers below for details 31

The exact I/O-configuration for circuits A, B, C and D is order-specific and can be determined by the CG32 number shown on the converter - check the data on the back of the MFC300 electronic unit. The CG32 number contains 10 characters of which the last three (XYZ) determine the I/O configuration (I/O circuits): 32 CG32 * * * X Y Z pos 1.. 4 5 6 7 8 9 10 determine I/O circuits Schematic overviews of the CG32 numbers can be found in paragraph 4.2 (non-ex i signal I/O connections) and 4.3 (Ex i signal I/O connections). The overviews do not show all details. The exact connection diagram for a specific MFC 300 converter can be found on the sticker inside the cover of the connection compartment. For use in Gas Hazardous Areas: The chosen cable glands must have the appropriate type of protection for the terminal compartment, that is increased safety (Ex e) or flameproof enclosure (Ex d). They MUST be suitable for the conditions of use and correctly installed. The flowmeter with an Ex e terminal compartment is supplied ex-factory with two Ex e certified cable glands and one Ex e stopping plug. The flowmeter with an Ex d terminal compartment is supplied ex-factory one Ex d stopping plug and two temporarily plugs. The two temporarily plugs only for transport and storage must be replaced by suitable Ex d certified glands, plugs or conduit accessories before the flowmeter is taken into service. Unused openings must be closed by suitable certified plugs The wiring of the compact flowmeter has to conform to the requirements specified in the relevant national or regional standard for electrical installations in hazardous areas, e.g. IEC/EN 60079-14. From this standard section 9 (Wiring systems) is valid for all types of protection. Section 10 (additional requirements for type of protection d Flameproof enclosures), section 11 (additional requirements for type of protection e Increased safety) and section 12 (additional requirements for type of protection I Intrinsic safety) are valid for Ex e, Ex d or Ex i connection compartments respectively. Tighten teriminals to a torque setting of 0.7 Nm. The compact flowmeter must always be included in the equipotential bonding system of the hazardous area. This can be achieved internally by means of the PE conductor of the mains system connected to the internal PE clamp or externally by means of a separate equipotential bonding conductor connected to the external PE clamp under the converter housing. A separate bonding conductor must have a cross sectional area of at least 4 mm 2. 4.2 Non-Ex i signal I/O connections The following non-intrinsically safe signal inputs/outputs are available: I/O PCB Basic I/O Modular I/O Modular carrier with 1 or 2 I/O modules Profibus DP I/O Fieldbus I/O RS485 Modbus Input/output functions, Un < 32 V DC, In < 100 ma Um = 253 V Current Output active and passive, with HART Status Output / Control Input Status Output Pulse / Status Output Current Output, active or passive, with HART Pulse / Status Output, active or passive, highc or Namur Each module: 1 out of following 3 in/output functions: Current Output, active or passive Status / Pulse Output, active or passive, highc or Namur Control Input, active or passive, highc or Namur Profibus-DP, active Profibus-PA or Foundation Fieldbus Modbus with or without termination

The options separated with / are software selectable (can be changed by user) The options separated by or are hardware versions (must be ordered as such) All outputs are passive unless otherwise indicated HighC means High Current input/output, Namur means input/output to Namur recommendations Overview of possible combinations, defined by the CG32 number Characters XYZ Name I/O circuits Terminals A, A- Terminals B, B- Terminals C, C- Terminals D, D- 100 Basic I/O CO CO (a) over A+ SO/CI SO PO/SO 488 to 4RR 588 to 5RR 688 to 6RR 788 to 6RR 888 to 8RR A88 to ARR B88 to BRR C88 to CRR Modular I/O or Modular Carrier with 1 or 2 I/O Modules Many combinations possible D88 D8A to DRR E88 Fieldbus I/O Profibus PA Fieldbus I/O Profibus PA with Module Carrier with 1 or 2 I/O Modules Fieldbus I/O Foundation Fieldbus n.c. n.c. PA PA many combinations possible PA PA n.c n.c FF FF E8A to ERR Fieldbus I/O Foundation Fieldbus with Module Carrier with 1 or 2 I/O Modules many combinations possible FF FF F00 Profibus DP I/O n.c DP(a) DP(a) DP(a) F80 to FRO Profibus DP I/O with 0 or 1 I/O many combinations DP(a) DP(a) DP(a) G00 to GRR H00 to HRR RS485 Modbus Modbus with 1 or 2 I/O modules Many combinations possible RS485 RS485 shorts for in/output functions: CO= current output, PO=Pulse Output, SO= Status Output, CI= Control Input, PA=Profibus PA, FF=Foundation Fieldbus, DP=Profibus DP; RS458= RS485 Modbus. all in/outputs are passive unless otherwise noted as active (a) n.c. = not connected. 33

4.3 Ex i signal I/O connections Following intrinsically safe signal I/Os are available: I/O PCB I/O functions Ex i I/O Ex i Option or Ex i Option2 Fieldbus I/O Current Output + HART communication Pulse / Status Output Current Output, active + HART communication Current input passive Current Output Pulse / Status Output / Control Input Current Output, active Current input active Profibus-PA Foundation Fieldbus Ex ia IIC Ui =30V, Ii = 100 ma, Pi = 1,0 W Ci = 10nF, Li = negligibly low Ex ia IIC Uo = 21 V, Io = 90 ma, Po = 0,5 W linear characteristic Co = 90 nf, Lo =2,0 mh Co = 110 nf, Lo =0,5 mh Ex ia IIC Ui =30V, Ii = 100 ma, Pi = 1,0 W Ci = 10nF, Li = negligibly low Ex ia IIC Uo = 21 V, Io = 90 ma, Po = 0,5 W linear characteristic Co = 90 nf, Lo = 2,0 mh Co = 110 nf, Lo = 0,5 mh Ex ia IIC Uo = 24.1 V, Io = 99 ma, Po = 0,6 W linear characteristic Co = 75 nf, Lo = 0.5 mh Ex ia IIC Ui = 24 V, Ii = 380 ma, Pi = 5,32 W Ci = 5 nf, Li = 10 μh suitable for connection to an intrinsically safe fieldbus in accordance with the FISCO-model The I/O circuits named Ex i I/O, Ex i Option are always in the Intrinsically safe (Ex ia) type of protection. The I/O circuits Fieldbus I/O Profibus PA and Fieldbus I/O Foundation Fieldbus can be in the Intrinsically safety type of protection. A maximum of 4 intrinsically safe (Ex ia) in/outputs are possible. All intrinsically safe circuits are galvanically insulated with respect to earth and each other. To avoid summation of voltages and currents, the wiring of these Ex ia circuits must be sufficiently separated, e.g. in line with the requirements of standard IEC/EN 60079-14, clause 12.2. The Ex ia signal in/outputs may only be connected to other Ex ia or ib certified device (e.g. intrinsically safe isolation amplifiers), even if such devices are installed in the non-hazardous area! Connection to a non-ex i apparatus cancels the Ex ia properties of the flowmeter. Terminals L, N (or L+, L-) for mains connection are always non-intrinsically safe. To achieve the necessary spatial separation to IEC/EN 60079-11 between the non-ex i and Ex i circuits, the mains terminals are provided with a semi-circular insulation cover with a "snap-in" lock. This cover MUST be closed before establishing the power supply to the converter. 34

Overview possible CG32 numbers with Ex ia in/outputs Characters XYZ Name I/O circuits Terminals A, A- Terminals B, B- Terminals C, C- Terminals D, D- 200 Ex i I/O n.c. n.c. CO (a) PO/SO 300 n.c. n.c. CO PO/SO 210 Ex i I/O with CO (a) PO/SO/CI CO (a) PO/SO Ex i Option 220 CO PO/SO/CI CO (a) PO/SO 310 CO (a) PO/SO/CI CO PO/SO 320 CO PO/SO/CI CO PO/SO D00 Fieldbus I/O Profibus PA n.c. n.c PA PA D10 Fieldbus I/O Profibus PA with Ex i Option CO (a) PO/SO/CI PA PA D20 CO PO/SO/CI PA PA E00 Fieldbus I/O Foundation n.c. n.c FF FF Fieldbus E10 Fieldbus I/O Foundation Fieldbus withex i Option CO (a) PO/SO/CI FF FF Abbreviations for in/output functions: CO= current output, PO=Pulse Output, SO= Status Output, CI= Control Input, PA=Profibus PA, FF=Foundation Fieldbus, DP=Profibus DP All in/outputs are passive unless otherwise noted as active (a) n.c. = not connected 35

5 SERVICE AND MAINTENANCE 5.1 Maintenance OPTIMASS The OPTIMASS / OPTIGAS flowmeters are maintenance free with respect to the flowmetering properties. Within the scope of periodic inspections required for electrical equipment installed in hazardous areas it is recommended to check the flameproof converter housing and covers for signs of damage or corrosion. 5.2 Replacement of mains fuse Open the window cover. Press the two metal clips on each side of the display and pull the display unit forward. Move the display-unit sideward, out of the way. Loosen the two crosshead screws holding the electronic unit is place. Slide the electronic unit forward, with care. When the unit is almost completely removed from the housing, disconnect the long rectangular (10- pole) blue connector at the back-end of the unit. This connector is for the flow sensor circuits. Remove the unit from the housing. The mains fuse is situated in a fuse holder at the back-end of the electronic unit. The specification must be as follows: Fuse type: 5 x 20 mm (H) according to IEC 60127-2/V Power Supply: Time Lag: KROHNE Part Number: 12-24 VDC 250V / 2A 5060200000 24 VAC/DC 250V / 2A 5060200000 100-230 VAC 250V / 0.8A 5080850000 5.3 Returning the device for service or repair This device has been carefully manufactured and tested. If installed and operated in accordance with these operating instructions, it will rarely present any problems. Should you need to return a device for inspection or repair, please pay strict attention to the following points: Due to statutory regulations on environmental protection and safeguarding the health and safety of our personnel, KROHNE may only handle, test and repair returned devices that have been in contact with products without risk to personnel and environment. This means that KROHNE can only service this device if it is accompanied by the following certificate confirming that the device is safe to handle. If the device has been operated with toxic, caustic, flammable or water polluting liquids, you are kindly requested: To check and ensure, if necessary by rinsing or neutralizing, that all cavities in the device are free from dangerous substances. To enclose a certificate with the device confirming that it is safe to handle and stating the product used. We cannot service your device unless accompanied by a certificate. The specimen shown in appendix 1 can be photocoppied and used and it is also available on the KROHNE website as a word file. Simply download and use the tabulator key to go from one fillout field to the next. Please attach the form to the returned device 36

Appendix 1 Declaration of Cleanliness Certificate Company:...................................Address:.......................................................................................................................... Department:................................Name...................................... Tel. No......................................Fax No.:.................................... The enclosed device Type:.................................................................................. KROHNE Order No. or Series No.:......................................................... has been operated with the following liquid:................................................. Because this liquid is water-hazardous toxic caustic flammable we have checked that all cavities in the instrument are free from such substances / flushed out and neutralized all cavities in the device We confirm that there is no risk to humans or environment through any residual liquid contained in this device. Date:.......................................Signature:.................................. Company stamp: 37

38

39

KROHNE 03/2014 03491701 Krohne reserves the right to make changes without prior notice Australia KROHNE Australia Pty Ltd Quantum Business Park 10/287 Victoria Rd Rydalmere NSW 2116 TEL.: +61 2 8846 1700 FAX: +61 2 8846 1755 e-mail: krohne@krohne.com.au Austria KROHNE Austria Ges.m.b.H. Modecenterstraße 14 A-1030 Wien TEL.: +43(0)1/203 45 32 FAX: +43(0)1/203 47 78 e-mail: info@krohne.at Belgium KROHNE Belgium N.V. Brusselstraat 320 B-1702 Groot Bijgaarden TEL.: +32(0)2-4 66 00 10 FAX: +32(0)2-4 66 08 00 e-mail: krohne@krohne.be Brazil KROHNE Conaut Controles Automaticos Ltda. Estrada Louis Pasteur, 230 C.P. 56 06835-080 EMBU - SP TEL.: +55(0)11-4785-2700 FAX: +55(0)11-4785-2768 e-mail: conaut@conaut.com.br China KROHNE Measurement Instruments (Shanghai) Co. Ltd. 9th Floor, Xujiahui International Building 1033 Zhaojiabang Road Shanghai 200030 P. R. China TEL.: +86 21 6487 9611 FAX: +86 21 6438 7110 e-mail: info@krohne-asia.com CIS Kanex KROHNE Engineering AG Business-Centre Planeta, Office 3 Marxistskaja-Street 3 109147 Moscow/Russia TEL.: +7(0)095-9117 165 FAX: +7(0)095-9117 231 e-mail: krohne@dol.ru Czech Republic KROHNE CZ, spol. s r.o. Sobìšická 156 63800 Brno TEL.: +420 545 532 111 FAX: +420 545 220 093 e-mail: brno@krohne.cz France KROHNE S.A.S. Les Ors BP 98 F-26103 ROMANS Cedex TEL.: +33(0)4-75 05 44 00 FAX: +33(0)4-75 05 00 48 e-mail: info@krohne.fr Germany KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. D-47058 Duisburg TEL.: +49(0)203-301-0 FAX: +49(0)203-301-10 389 e-mail: info@krohne.de India KROHNE Marshall Ltd. A-34/35, M.I.D.C. Industrial Area, H-Block, Pimpri Poona 411018 TEL.: +91(0)202-7442020 FAX: +91(0)202-7442020 e-mail: pcu@vsnl.net Iran KROHNE Liaison Office North Sohrevardi Ave. 26, Sarmad St., Apt. #9 Tehran 15539 TEL.: ++98-21-874-5973 FAX: ++98-21-850-1268 e-mail: krohne@krohneiran.com Italy KROHNE Italia Srl. Via V. Monti 75 I-20145 Milano TEL.: +39(0)2-4 30 06 61 FAX: +39(0)2-43 00 66 66 e-mail: info@krohne.it Korea KROHNE Korea Room 508 Miwon Bldg 43 Yoido-Dong Youngdeungpo-Ku Seoul, Korea TEL.: 00-82-2-780-1743 FAX: 00-82-2-780-1749 e-mail: krohnekorea@krohnekorea.com Netherlands KROHNE Altometer Kerkeplaat 12 NL-3313 LC Dordrecht TEL.: +31(0)78-6306300 FAX: +31(0)78-6306390 e-mail: postmaster@krohne-altometer.nl Netherlands KROHNE Nederland B.V. Kerkeplaat 14 NL-3313 LC Dordrecht TEL.: +31(0)78-6306200 FAX: +31(0)78-63065 Service Direkt: +31(0)78-6306222 e-mail: info@krohne.nl Norway KROHNE Norway A.S. Ekholtveien 114 NO-1526 Moss P.O. Box 2178, NO-1521 Moss TEL.: +47(0)69-264860 FAX: +47(0)69-267333 e-mail: postmaster@krohne.no Internet: www.krohne.no Singapore Tokyo Keiso - KROHNE Singapore Pte. Ltd. 14, International Business Park, Jurong East Chiyoda Building #01-01/02 Singapore 609922 Singapore TEL.: ++65-65-67-4548 FAX: ++65-65-67-9874 South Africa KROHNE Pty. Ltd. 163 New Road Halfway House Ext. 13 Midrand TEL.: +27(0)11-315-2685 FAX: +27(0)11-805-0531 e-mail: midrand@krohne.co.za Spain I.I. KROHNE Iberia, S.r.L. Poligono Industrial Nilo Calle Brasil, n. 5 E-28806 Alcalá de Henares-Madrid TEL.: +34(0)91-8 83 21 52 FAX: +34(0)91-8 83 48 54 e-mail: krohne@krohne.es Switzerland KROHNE AG Uferstr. 90 CH-19 Basel TEL.: +41(0)61-638 30 30 FAX: +41(0)61-638 30 e-mail: info@krohne.ch United Kingdom KROHNE Ltd. Rutherford Drive Park Farm Industrial Estate Wellingborough, Northants NN8 6AE, UK TEL.: +44(0)19 33-8 500 FAX: +44(0)19 33-8 501 e-mail: info@krohne.co.uk USA KROHNE Inc. 7 Dearborn Road Peabody, MA 01960 TEL.: +1-978 535-6060 FAX: +1-978 535-1720 e-mail: info@krohne.com Other Representatives Algeria Argentina Belarus Cameroon Canada Chile Colombia Croatia Denmark Ecuador Egypt Finland Gabon Ghana Greece Hong Kong Hungary Indonesia Ivory Coast Iran Ireland Israel Japan Jordan Kuwait Libya Lithuania Malaysia Morocco Mauritius Mexico New Zealand Peru Poland Portugal Romania Saudi Arabia Senegal Slovakia Slovenia Sweden Taiwan Thailand Turkey Tunisia Venezuela Yugoslavia Other Countries KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. D-47058 Duisburg TEL.: +49(0)203-301-0 FAX: +49(0)203-301-389 e-mail: export@krohne.de Subject to change without notice