Area Referencing Report in accordance with the RICS Code of Measuring Practice Culverdon, Pyrcroft Road, Chertsey KT16 9LE

Similar documents
AREA MEASUREMENT REPORT (RICS Code of Measuring Practice) 6 MARKET ROAD LONDON N7

AREA MEASUREMENT REPORT (RICS Code of Measuring Practice) 1 BERRY PLACE LONDON EC1V

High Barn EFFINGHAM, SURREY

GUIDANCE NOTES FOR GNSS NETWORK RTK SURVEYING IN GREAT BRITAIN

PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 PRECAST CONCRETE ELEMENT DESIGN RESPONSIBILITIES AND CONTRACTUAL ARRANGEMENTS

The Bonded Warehouse ManChesTer s InnoVaTIon district

NZQA unit standard version 3 Page 1 of 5. Install and maintain telecommunications radio frequency systems

Geometric Survey Report

CLIENT GUIDE TO MEASURED BUILDING SURVEYS

Robert Bond Partner, Commercial/IP/IT

South West Public Engagement Protocol for Wind Energy

Estates Development & Projects

NOISE IMPACT ASSESSMENT 2016

Elmara Pett Level Road, Pett Level, Hastings, East Sussex, TN35 4EH

Drawing Standard for Plans Showing Horizontal Alignment

National Grid s commitments when undertaking works in the UK. Our stakeholder, community and amenity policy

TEACHING SCHEME & EXAMINATION 4 th year B. Arch

THIRD SCHEDULE Form of Application For A Revised Disability Access Certificate Article 20E(2)

BLAYDON TRADE PARK I & II, BLAYDON, NEWCASTLE UPON TYNE, NE21 5AB. Trade Park Investment Opportunity

RUGBY BUSINESS PARK NEW BUILD WAREHOUSE/INDUSTRIAL UNIT ON A SITE 0F 3 ACRES AVAILABLE NOW 59,489 SQ FT

Ref: S935/gb. 13 th April 2012

SAMPLING SAMPLING C Model: C Product Data Sheet Precision Haptic 13mm Linear Resonant Actuator - 3mm Type

Sheetlines The journal of THE CHARLES CLOSE SOCIETY for the Study of Ordnance Survey Maps

Stanford University-Facilities Design Guideline SECTION Plans Review Submission Guidelines

The following items are updated to reflect revisions and are hereby incorporated into the Inquiry Documents, Inquiry No. 17-WDI-031.

Chapel Farm House OAKHANGER I HAMPSHIRE I GU35 9JB

NZFSA Policy on Food Safety Equivalence:

Section Meetings Section Material and Equipment. None Required

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.

Mill Lane, Cookham, Maidenhead, Berkshire

This specification describes the general requirements for Engineering Services provided to Vale.

BROOKINGS municipal utilities

A10 Electronic Interference: Application 2 - LBHF

FIT-OUT PERMIT REQUEST (GENERAL WORKS)

Media and Entertainment. A guide to our offering

Guidelines for the avoidance of vibration induced fatigue failure in process pipework

With you from the spark

THERMISTORS (THERMALLY SENSITIVE RESISTORS), NTC, RANGE 2000 TO OHMS AT +25 O C WITH A TEMPERATURE RANGE OF -60 O C TO +160 O C

Brad Luke. Director Peddle Thorp Auckland

Technical Support to Defence Spectrum LTE into Wi-Fi Additional Analysis. Definitive v1.0-12/02/2014. Ref: UK/2011/EC231986/AH17/4724/V1.

Report. Temporary abandoned wells on NCS. Subtitle. Author(s) Nils Totland. SINTEF Petroleum Research Well Integrity

Manually verifiable area calculations; and BC Land Surveyor certified area calculations (typically practical only for large development proposals).

ELECTRONIC DRAFTING GUIDELINES

THE GRID CODE OC7.5 INTEGRAL EQUIPMENT TESTS GUIDANCE NOTES

Application Number: 17/00266/FUL. Photo 1. Photo 2

THE GRID CODE OC7.5 INTEGRAL EQUIPMENT TESTS

DOWNTOWN DEVELOPMENT REVIEW BOARD APPLICATION

INS Process Outline Requirements

TEST REPORT. Rendered to: SOLATUBE INTERNATIONAL, INC. VISTA, CALIFORNIA

ISO INTERNATIONAL STANDARD. Industrial fans Specifications for balance quality and vibration levels

Architect s Letter of Certification

Metro Area Planning Agency. Request for Proposal Omaha-Lincoln Metro Area Imagery Project

1st Review of Submittal Materials for Willow Bend Development; CSP (Hansen #1734) Comment Responses

The following information supplements and/or supersedes the bid documents issued on July 10, 2017.

1.1 GENERAL RECORD DRAWING REQUIREMENTS

Coldra Woods Hotel by Celtic Manor and Starbucks Drive Thru Restaurant. Dormouse Method Statement

September 29 October 1, 2013 Indiana Convention Center 100 South Capitol, Indianapolis, Indiana 46225

Standard BAL b Automatic Generation Control

THE DESIGN PROCESS. for an interior design project

3. DESIGN SPECIFICATIONS

Standard BAL b Automatic Generation Control

Module 5: Plans, dimensions and tolerances

***************************************************************************** DRAFT UFGS- 01 XX XX (FEB 2014)

PROPORTIONATE EIA The Arcadis Perspective. David Hoare 18 July 2017

TSA Surveying Course

BritNed Interconnector between Holland and England. Methodology Statement for Determination of System-to-System Flows

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

NHS South Tees Clinical Commissioning Group. Governing Body. Agenda Item:

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007

Recreational Disturbance Study in relation to roosting and breeding wildfowl, waders and seabirds

REPORT PERIOD: JANUARY 01 MARCH

HYDROGRAPHIC SURVEY STANDARDS AND DELIVERABLES

RADIO SPECTRUM COMMITTEE

CCG Assurance and the Balanced Scorecard Balanced Scorecard An overview of the tool, and its role in CCG assurance. Khadir Meer Richard Wells

Three Snowhill, Birmingham. Site Specific Art Commission

ARTES Competitiveness & Growth Full Proposal. Requirements for the Content of the Technical Proposal. Part 3B Product Development Plan

SPECIFICATIONS FOR NEW UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS

March 12, Monica Estavillo San Jacinto Unified School District 905 Industrial Way San Jacinto, CA 92583

Architect s Letter of Certification

February Prepared for

looking west looking east A0.6 Proposed Development Model Shots 1327 Marine Drive West Vancouver revision date fax (604) phone (604)

Robotics, AI and the Law

RESIDENTIAL DEMOLITION PERMIT APPLICANT CHECKLIST

PRACTICAL UNDERSTANDING AND INTERPRETATION OF TECHNICAL STANDARD TS30a WELDING SPECIFICATION

ISO INTERNATIONAL STANDARD. Fluid power systems O-rings Part 1: Inside diameters, cross-sections, tolerances and designation codes

shedkm architects complete first Ruskin Square office in Croydon

ISO 860 INTERNATIONAL STANDARD. Terminology work Harmonization of concepts and terms. Travaux terminologiques Harmonisation des concepts et des termes

Booth Display Rules. Standard Inline booth. Perimeter booth. Island booth. Peninsula Booth

SUBMITTAL REQUIREMENTS FOR COMMERCIAL SIGNAGE PROJECTS

User Guide US AUS Avontus Software Corporation. All Rights Reserved

ISO/TR 2801 Clothing for protection against heat and flame General recommendations for selection, care and use of protective clothing

00-General Drawings. Doc. no.: NA-00-STS002

URBAN DRAINAGE AND FLOOD CONTROL DISTRICT

SYNCHRONISING AND VOLTAGE SELECTION

MERRY HILL MERRY HILL RETAIL PARK (PHASE 1 & PHASE 3) SAT NAV: DY5 1SY. New Letting to. New Letting to. Pedmore Road (A4036)

COMPILATION OF TENDER DOCUMENTS

TECHNOLOGY QUALIFICATION MANAGEMENT

TECHNICAL DESCRIPTION

Revision of the Public Law Outline

Centre For The Development Of Academic Skills (CeDAS) Royal Holloway Proofreading Scheme. Handbook and Code of Practice

Transcription:

Area Referencing Report in accordance with the RICS Code of Measuring Practice Culverdon, Pyrcroft Road, Chertsey KT16 9LE Prepared for Prepared by Berwick Hill Properties Tom Pugh BSc (Hons) MRICS Alistair Barrett BSc (Hons) Date 04 November 2016 Reference 54725/42/TP/AGB Prepared for Berwick Hill Properties Malcolm Hollis LLP 140 London Wall, London, EC2Y 5DN T 020 7622 9555 F 020 7627 9850 W malcolmhollis.com Malcolm Hollis LLP, a Limited Liability Partnership. Registered in England and Wales number OC314362. Registered office: Battersea Studios, 80-82 Silverthorne Road, London SW8 3HE. VAT number 863 8914 80. A list of members is available from our registered office. Regulated by RICS. Area Referencing Report Culverdon, Pyrcroft Road, Chertsey KT16 9LE

Contents Page 1. Introduction... 3 1.1 Brief... 3 1.2 Scope of Works... 3 1.3 Survey Method... 3 1.4 Area Calculation... 4 1.5 Quality Control... 4 2. Results and Report... 5 Appendix A Area Schedules Appendix B Area Floor Plans Area Referencing Report 2 Ref. 54725/PJH/TP Culverdon, Pyrcroft Road, Chertsey KT16 9LE 04 November 2016

1. Introduction 1.1 Brief 1.1.1 We were instructed by our client Berwick Hill Properties to measure the Net Internal Area (NIA) of Culverdon, Pyrcroft Road, Chertsey, KT16 9LE. 1.1.2 The measuring and subsequent calculations were undertaken by Malcolm Hollis LLP in November 2016, in accordance with the RICS Code of Measuring Practice 6th Edition (September 2007), under site conditions at that time and in line with Malcolm Hollis s standard conditions of contract. 1.2 Scope of Works 1.2.1 Area measurements were required for all floors of the building. 1.2.2 The areas measured were as found on site, in accordance with the Measuring Guidance Notes. Lease plans with demise areas outlined, were unavailable. 1.2.3 The report was prepared in November 2016, in response to our client s particular instructions and you should note that the physical state of the property may have changed in the intervening period between our inspection and the date of this report. 1.3 Survey Method 1.3.1 Measurements were taken to the internal face of perimeter walls and to the face of walls enclosing toilets, stairs and other core areas. Where these were not accessible, professional estimations may have been made based upon the location of these walls on adjacent floors and/or on information contained on supplied drawings. 1.3.2 MBS Floor Plan software and Leica Disto laser devices were used to capture the dimensions of the building. The bearings and distances are automatically stored on handheld tablet computers, together with overall distances, cross brace measurements and check measurements whilst on site to eliminate errors or omissions and the data later downloaded to office computers. 1.3.3 Where detailed measurements could not be taken due to occupation and fixtures, a visual check was undertaken and professional estimations made. 1.3.4 This survey has been carried out to an accuracy of +/- 10mm as per the guidance detailed in the RICS guidance note Measured surveys of land, buildings and utilities (3 rd Edition, 2014). Area Referencing Report 3 Ref. 54725/PJH/TP Culverdon, Pyrcroft Road, Chertsey KT16 9LE 04 November 2016

1.4 Area Calculation 1.4.1 Every effort is made to ensure the survey is as accurate as possible. Site survey work and corresponding accuracy levels are constrained by the methods adopted to capture relevant site data, the nature of access afforded and the time allocated to complete the work. 1.4.2 AutoCAD is used to produce accurate drawings using the information collected on site from which area values are calculated. The production of these drawings allows the creation of a polygon outlining the perimeter of the space and then the subsequent calculation of the overall area using the area calculation function within AutoCAD. 1.4.3 The relevant scale of the area reference drawings is stated on the drawings. 1.4.4 The drawings have been saved as digital DWG files comprising accurate data of areas extents and configurations that could be used as a basis for future space management, lease plans or refurbishment purposes. 1.4.5 The areas have been summarised on a schedule for easy reference, however the two elements (the plans and the schedule) of the document should be read together as there may be information on one that is not contained on the other. 1.5 Quality Control 1.5.1 All site dimensions were checked using in-house computer technology and any discrepancies exceeding the required tolerance were, if necessary, verified whilst on site. 1.5.2 All figures and drawings are checked as part of our standard quality control procedures. 1.5.3 To minimise errors and deliver final area figures to an expected or agreed level the following procedures form part of the quality control process: Linear site dimensions recorded are within the necessary tolerances. Equipment checks and calibrations are in place to support the accuracy of the measurement. Sufficient redundancy of recorded dimensions to mitigate erroneous ones. Software check routines for area calculation. Area Referencing Report 4 Ref. 54725/PJH/TP Culverdon, Pyrcroft Road, Chertsey KT16 9LE 04 November 2016

2. Results and Report 2.1.1 The resultant area figures detailing the extent of the property measured are presented in Appendix A (Area Schedules). 2.1.2 The floor plans (showing the extent of the areas measured, identifying specific areas of inclusion/exclusion and quoting area values in square metres and square feet) are presented in Appendix B (Area Floor Plans). These plans are also available in digital format, which may be useful in the future for space management or refurbishment purposes. Area Referencing Report 5 Ref. 54725/PJH/TP Culverdon, Pyrcroft Road, Chertsey KT16 9LE 04 November 2016

Appendix A Area Schedules

SUMMARY OF AREAS Culverdon, Pycroft Road, Chertsey KT16 9LE Floor Use sq. m. Net Internal Area sq. ft. Comments Ground Office 861.9 9,278 Reception 33.6 362 Ground Floor Total 895.5 9,640 First 903.0 9,720 Second 293.8 3,163 Totals 2092.3 22,523 Notes: A factor of 10.7639 has been used to convert from sq. m. to sq. ft. Area Summary Culverdon, Pyrcroft Road, Chertsey KT16 9LE 04 November 2016 54725/42/TP/AGB

Appendix B Area Floor Plans

Stairs Lifts 16.07 Stairs 50.48 GROUND FLOOR PROPERTY CULVERDON PYCROFT ROAD CHERTSEY KT16 9LE NOTES 1) ALL DIMENSIONS TO BE CHECKED ON SITE AND NOT SCALED FROM THIS DRAWING. 2) MALCOLM HOLLIS SHALL BE INFORMED IN WRITING OF ANY DISCREPANCIES. 3) ALL DIMENSIONS ARE IN METRES. SCALED FROM THIS DRAWING. 4) ALL AREAS ARE MEASURED IN ACCORDANCE TO THE RICS CODE OF MEASURING PRACTICE (6th Edition). REVISIONS OFFICE RECEPTION TOTAL AREA: NET INTERNAL AREAS 861.9 sq m 9,278 sq ft 33.6 sq m 362 sq ft 895.5 sq m 9,640 sq ft 80-82 Silverthorne Road London SW8 3HE T 020 7622 9555 W malcolmhollis.com DRAWN BY AMB SURVEY DATE 11.10.16 SCALE 1:200 CHECKED AGB DRAWING NO. REV. NO. 54725-AR-G

Stairs Lifts 16.07 Stairs 50.46 FIRST FLOOR PROPERTY CULVERDON PYCROFT ROAD CHERTSEY KT16 9LE NOTES 1) ALL DIMENSIONS TO BE CHECKED ON SITE AND NOT SCALED FROM THIS DRAWING. 2) MALCOLM HOLLIS SHALL BE INFORMED IN WRITING OF ANY DISCREPANCIES. 3) ALL DIMENSIONS ARE IN METRES. SCALED FROM THIS DRAWING. 4) ALL AREAS ARE MEASURED IN ACCORDANCE TO THE RICS CODE OF MEASURING PRACTICE (6th Edition). REVISIONS OFFICE TOTAL AREA: NET INTERNAL AREAS 903.0 sq m 9,720 sq ft 903.0 sq m 9,720 sq ft 80-82 Silverthorne Road London SW8 3HE T 020 7622 9555 W malcolmhollis.com DRAWN BY AMB SURVEY DATE 11.10.16 SCALE 1:200 CHECKED AGB DRAWING NO. REV. NO. 54725-AR-1

15.83 Lifts 22.12 Stairs SECOND FLOOR PROPERTY CULVERDON PYCROFT ROAD CHERTSEY KT16 9LE NOTES 1) ALL DIMENSIONS TO BE CHECKED ON SITE AND NOT SCALED FROM THIS DRAWING. 2) MALCOLM HOLLIS SHALL BE INFORMED IN WRITING OF ANY DISCREPANCIES. 3) ALL DIMENSIONS ARE IN METRES. SCALED FROM THIS DRAWING. 4) ALL AREAS ARE MEASURED IN ACCORDANCE TO THE RICS CODE OF MEASURING PRACTICE (6th Edition). REVISIONS OFFICE TOTAL AREA: NET INTERNAL AREAS 293.8 sq m 3,163 sq ft 293.8 sq m 3,163 sq ft 80-82 Silverthorne Road London SW8 3HE T 020 7622 9555 W malcolmhollis.com DRAWN BY AMB SURVEY DATE 11.10.16 SCALE 1:200 CHECKED AGB DRAWING NO. REV. NO. 54725-AR-2