MPD 500. Partial Discharge Measuring System for Routine Test Applications

Similar documents
Advanced Test Equipment Rentals ATEC (2832)

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

MPD 500. Partial discharge measurement system for routine test applications

MPD 600. High-End Measurement and Analysis System for Partial Discharges (PD)

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

FRAnalyzer. Reliable core and winding diagnosis for power transformers

CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for

Primary Test Manager (PTM) Testing and management software for primary assets

MPD 600. High-end partial discharge measurement and analysis system

MPD 600. High-end measurement and analysis system for partial discharges

Advanced Test Equipment Rentals ATEC (2832)

MPD 600. High-end partial discharge measurement and analysis system

Why partial discharge testing makes good sense

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

MONTRANO. Continuous monitoring system for power transformers

CMC 256plus - protection relay test set and universal calibrator

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

The importance of partial discharge testing throughout the development and operation of power transformers

TESTRANO 600 ordering information

Diagnostic testing of cast resin transformers

CP CU1. Coupling unit for line and ground testing

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

CT Analyzer. Revolution in current transformer testing and calibration

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

MEDIUM & HIGH VOLTAGE

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Three-Phase Transformer Test Systems

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

D D X. Digital Partial Discharge Detector

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM

Comparison of capacitive and inductive sensors designed for partial discharges measurements in electrical power apparatus

Partial Discharge Detector and Radio Interference Voltage Testing

NEW MV CABLE ACCESSORY WITH EMBEDDED SENSOR TO CHECK PARTIAL DISCHARGE ACTIVITY

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

PHG 70 TD PD / PHG 80 TD PD

PD Solutions. On-Line PD Measurement Devices

TESTRANO 600. Three-phase test system for comprehensive power transformer testing

FRAX Series Sweep Frequency Response Analyzers

BM25 Automated 5-kV Insulation Tester

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Keysight Technologies USB Preamplifiers

VOTANO 100. Accurate and mobile voltage transformer testing and calibration system

Isolation Addresses Common Sources of Differential Measurement Error

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

TESTRANO 600. Three-phase test system for comprehensive power and distribution transformer testing

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Cable test vans and systems

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DOBLE F6150SV TECHNICAL SPECIFICATIONS

FRAX Series Sweep Frequency Response Analyzers

Fluke 5820A Oscilloscope Calibrator Specifications

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Insulating oil testing

DSA700 Series Spectrum Analyzer

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Cable test vans and systems

MODEL INFORMATION. AccuLoss MODELS ALMS 2100, ALMS 4100, ALMS 4200, ALMS 6200 & ALMS 4300

6135A/PMUCAL Phasor Measurement Unit Calibration System

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CT Analyzer. Current transformer testing, calibration and assessment

New Techniques for the Monitoring of Transformer Condition

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Centrix 2.0 The world s most modern and powerful cable test van system

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Appendix A: Specifications

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA

30 A AC/DC Current Probe TCP0030A Datasheet

MIT510/2, MIT520/2 and MIT1020/2

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

PRELIMINARY DATA. Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

Agilent U9397A/C FET Solid State Switches (SPDT)

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

Cable testing and diagnostics

Measuring Power Line Impedance

DOBLE F6150e TECHNICAL SPECIFICATIONS

8588A Reference Multimeter

DC Biased Impedance Measurements MOSFET

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Instrument. Specifications OR34/35. SmartRouter. 2 to 8 Channels Multi-Analyzers. Controller Unit TECHNICAL SPECIFICATIONS

MIT510, MIT520 and MIT1020

Transcription:

MPD 500 Partial Discharge Measuring System for Routine Test Applications

Partial Discharge Measurement The MPD 500 partial discharge measuring system has been specially designed for providing fast and reliable results in a highthroughput environment. As a new member of the successful OMICRON MPD family with hundreds of systems worldwide in daily use, the MPD 500 is the ideal solution for state-of-the-art routine testing, clear pass / fail decisions and most easy reporting. Reliable evaluation of insulating systems PD - Partial Discharges are defined as localized electrical discharge that only partially bridge the insulation between conductors, often preceding an insulation breakdown. Therefore PD measurements are well established and widely accepted for quality assurance and factory testing of mediumand high-voltage assets. Modern PD measurement systems based on apparent charge [pc], in accordance with IEC 60270, reveals faulty spots in electrical insulations with a high degree of sensitivity. RIV - Radio Influence Voltage measurements express partial discharge activities as a voltage that appears on conductors of electric equipment. The RIV value is displayed in µv according to CISPR 16-1-1 and the still referenced NEMA 107-1987. The most convenient way to measure PD As the newest member of OMICRON's successful PD measurement family, the MPD 500 benefits from the experience of hundreds of MPD units in daily use by major cable-, transformer-, and rotating machine manufacturers worldwide. By incorporating a wide range of leading-edge technologies, highly sensitive and accurate results can be obtained by the MPD 500 as easily as operating a voltmeter. The user-friendly software provides full remote control of the measurement devices and delivers very easy automated reporting of PD / RIV measurements. The MPD 500 also holds simultaneous multi-channel abilities, without the need for a multiplexer. 300 2 kv high voltage laboratory PFIFFNER Instrument Transformers Ltd. / Switzerland

Results at one glance Single and multi-channel view Advantages of the intuitive MPD 500 software: > > Concise visualization of single as well as multi-channel measurements > > User-friendly pass / fail functionality > > Detailed diagrams for in-depth analysis For factory routine testing the conclusive pass / fail function is ideal for fast decisions. Adjusting the thresholds is most easy, as are the inception and extinction voltage. Using the MPD's multi-channel ability allows to display multiple actual PD measurement values simultaneously on one screen, contrasting old-fashioned multiplexer solutions. This makes the MPD 500 ideal for PD measurements in high-throughput environments. For advanced analysis classic ellipse and state-of-the-art PRPD (ϕ-q-n) visualizations show partial discharge activities in real time at 25 frames per second. Automate your reports Ellipse and PRPD (ϕ-q-n) screens The optional comprehensive electronic reporting function automatically provides a concise test protocol within seconds. These reports contain information about the tested object, the measurement, and all data in definable intervals, as well as diagrams showing Q(t), U(t), and Q(U). Individual screenshots can be inserted during measurement at any time by simply hitting a hotkey. Automated reports Your benefits > > Economical - PD and RIV are combined within one instrument > > Time effective, easy operation > > Decision support with clear pass / fail indication > > Efficient multi-channel testing with several results displayed simultaneously > > Save time - Fast and easy automated reporting 3

Excellent Noise Suppression There are many sources of interference which can complicate the measurement of partial discharges. The MPD 500 provides effective features for reducing or eliminating the effect of these disturbances, making the measurements more reliable and accurate. Advantages of fiber-optic communication The whole MPD family utilizes the "point of PD measurement", processing and digitizing in close proximity to the coupling device as shown below. The digitized signal is transferred to the operator's control room using optical communication. This principle minimizes the effective ground loop and the influence of external interferences resulting in a significantly reduced background noise level. Electromagnetic disturbances of nearby HV equipment have no influence on optical fibers, therefore cable routing is fast and easy, without special precautions. Safety comes first - the fully galvanic isolation between "point of PD measurement" and control room sets new standards of operational safety even during a breakdown of the test object. Very long fiber-optic connections may be used without degrading the instrument's performance - The distance between PD detection and operator could get up to 2 km / 1.2 miles. Active noise suppression The center frequency can comfortably be adjusted via slider from 0 MHz to 2.5 MHz. Together with three selectable bandwidths, the MPD 500 can be tuned away from noise to a more "quiet" frequency range, focusing optimally on the test object's PD signals. Simply use the mouse to enable an unlimited number of phase amplitude gates for effective suppression of phase-fixed disturbances. Battery-powered portability In addition to the advanced "point of measurement" principle, even further circuit sensitivity can be realized by eliminating noise from the mains that power the MPD 500. Every unit is supplied with a battery attachment, that has the capability of powering the system for up to 20 hours of continuous operation. Noise-prone conventional PD detection method C2 Coupling capacitor Interference C3 C1 C2 C3 Coupling device / Measuring impedance 5-50 m Device Under Test Ground loop MPD: innovative desensitized PD detection Coupling capacitor C2 C3 C1 C2 C3 Coupling device / Measuring impedance Interference 0.3 m Point of PD measurement up to 2km Optical fiber Device Under Test MPD 500 and battery 4

Routine factory testing Routine PD measurements become easy with the integrated pass / fail functionality. Set the MPD 500 to the desired PD threshold level for the device under test. When this level is exceeded, it is clearly displayed in the main window. For further investigations the MPD 500 provides advanced visualization and diagnosis tools such as ellipse and PRPD (ϕ-q-n), typically only found in expensive high-end PD measurement systems. Shielded HF cable Point of PD measurement Wide range of applications Upgrade your testing facility to the latest technical benchmark in partial discharge measurements. The MPD 500 is ideal for examining PD faults in electrical insulations of transformers, bushings, generators, motors, and other types of electrical equipment in screened factory-routine-testing environments and testing laboratories. Adaptable to 19" format, the MPD 500 fills in for outdated built in instruments. This drop-in boosts control rooms to state-of-the-art PD measuring abilities, with all benefits of a contemporary PD system. Each replacement gets optimized to the individual demands. Contact your OMICRON sales representative for further details. Let the equipment grow with your needs If necessary the MPD 500 can be upgraded to OMICRON's wellestablished high-end MPD 600 PD measurement and analysis system at any time, even after several years in operation. This makes the MPD 500 the only risk-free choice for PD measurements, even if your demands grow. Your benefits > > Increased sensitivity due to greatly reduced background noise level > > Unrivaled operational safety with galvanic isolation > > Enhanced accuracy with progressive noise suppression tools > > Save time - fast upgrading solution for old built-in analog PD devices > > The only risk-free choice - upgradable to the most advanced PD measurement system 5

Technical Data and Order Information Coupling capacitors* VEHZ4115 MCC 124, 24 kv, 1.1 nf, dry coupling capacitor VEHZ4116 MCC 205**, 50 kv, 1.0 nf (on mobile base) VEHZ4117 MCC 210**, 100 kv, 1.0 nf (on mobile base) High frequency current transformer VEHZ4120 MCT 100 high frequency current transformer MPD 500 - Technical data Center frequency range Input freq. bandwidth 0 Hz to 2.5 MHz 100 khz, 300 khz, 1 MHz Input frequency range V input: 0 Hz to 4.3 khz PD input: 0 Hz to 2,5 MHz Input impedance V input: 1 MW, in parallel 1 µf PD input: 50 W Input voltage (max) V input: 60 V rms, PD input: 10 V rms Bushing adapters* (incl. transport case) VEHZ4121 Basic adapter: G3/4" inside to 5/8" VEHZ4122 F&G/HSP adapter: M24 to G3/4" VEHZ4123 HSP adapter: M30x1,5 to G3/4" Measuring impedances VEHZ4100 CPL 542, 0.5 A type VEHZ4101 CPL 542, 2 A type VEHZ4103 CPL 543, 5 A type Dynamic range PC requirements Hardware (minimum) PC operating system Accuracy PD event time resolution Input channels V input: 102 db, PD input: 132 db (overall) Pentium 4 or later, Athlon 64 or later / 1 GB RAM / USB 2.0 Windows 2000 Pro to Windows 7 < 2 ns PD level: ± 1 % of calibrated PD value Voltage: ± 0.05 % of calibrated voltage Frequency: ± 1 ppm Li-poly battery VEHZ4105 VEHZ4106 MPP 600 Power Pack Set (consisting of battery, fastener, and charger with power cord) MPP 600 battery Environmental conditions / mechanical data / supply voltage Humidity / temperature Dimension (W x D x H) 5 % to 100 % non-condensing 0 C to 55 C (operating) -10 C to 70 C (storage) 110 x 190 x 44 mm / 4.3 x 7.5 x 1.7 in * Customized articles available on request ** Including CPL measuring impedance Weight Power supply 600 g / 1.3 lbs 8 to 12 V DC via ext. power supply or MPP 600 Li-Poly battery 6

Packages VE004500 VE004501 VE004502 Software upgrades MPD 500 PD package: MPD 500 measuring system hardware (consisting of MPD 500, MCU 502, CPL 542 or 543, MPP 600 Power Pack Set, BNC measurement cables, and fiber optical communication cables) Transport case VEHP0044 Software for PD measurements plus manual MPD 500 RIV package: MPD 500 measuring system hardware (same hardware as in PD package incl. transport case) Software for RIV measurements plus manual Additional MPD 500 measuring channel (consisting of MPD 500, MPP 600 Power Pack Set, fiber optical communication cables) Fiber optical communication cables* VEHK4003 Length: 3 m / 10 ft VEHK4001 Length: 20 m / 65 ft VEHK4002 Length: 50 m / 165 ft (on cable drum) Fiber optical bus control unit VE004300 MCU 502 fiber optical bus controller Charge calibrators VE004200 Version A: 0.1 pc to 10 pc VE004210 Version B: 1 pc to 100 pc VE004220 Version C: 10 pc to 1000 pc VE004230 Version D: 0.1 nc to 10 nc VE004240 CAL 543 online charge calibrator VE004241 Remote control (required for CAL 543) VESM4500 VESM4501 VESM4502 MPD 500 PD software upgrade MPD 500 RIV software upgrade MPD 500 report functionality Protection cases VEHP0041 MPC 600 protection case Upgrades VE004503 Upgrade MPD 500 to MPD 600, the most advanced PD measurement system Transport cases VEHP0043 For up to three MCT 100 VEHP0044 For complete MPD system 7

OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis, and training make the product range complete. Customers in more than 140 countries rely on the company s ability to supply leading edge technology of excellent quality. Broad application knowledge and extraordinary customer support provided by offices in North America, Europe, South and East Asia, Australia, and the Middle East, together with a worldwide network of distributors and representatives, make the company a market leader in its sector. The following publication provides further information on the solutions described in this brochure MPD 600 Brochure For a complete list of available literature please visit our website. Americas OMICRON electronics Corp. USA 12 Greenway Plaza, Suite 1510 Houston, TX 77046, USA Phone: +1 713 830-4660 +1 800-OMICRON Fax: +1 713 830-4661 info@omicronusa.com Asia-Pacific OMICRON electronics Asia Limited Suite 2006, 20/F, Tower 2 The Gateway, Harbour City Kowloon, Hong Kong S.A.R. Phone: +852 3767 5500 Fax: +852 3767 5400 info@asia.omicron.at Europe, Middle East, Africa OMICRON electronics GmbH Oberes Ried 1 6833 Klaus, Austria Phone: +43 5523 507-0 Fax: +43 5523 507-999 info@omicron.at OMICRON L143, January 2012 Subject to change without notice www.omicron.at www.omicronusa.com