HK I. Anchor size (carbon steel) HK6 HK6L HK8 Resistance F Rk [kn] 2,0 5,0 5,0

Similar documents
HUS 6 Screw anchor, Redundant fastening

HPD Aerated concrete anchor. Approvals / certificates. Basic loading data (for a single anchor)

HUS3 redundant SCREW ANCHOR. Technical Datasheet Update: Dec-17

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear ICC. Steel failure

HSV EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Internal threaded version: HSC-I carbon steel internal version HSC-IR Stainless steel version (A4) Hilti anchor design software

HVU2 adhesive capsule Anchor design (ETAG 001) / Rods&Sleeves / Concrete

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

TECHNICAL DATA SHEET

TECHNICAL DATASHEET MULTI ANCHOR GREEN PLUS styrene-free hybrid formulation chemical anchor

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Oct-18

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Hilti HIT-HY 200 with HIT-Z

Anchor Fastening Technology Manual 09 / 2012

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

HUS-V SCREW ANCHOR. Technical Datasheet Update: Dec-17

European Technical Assessment. ETA-14/0426 of 21 December English translation prepared by DIBt - Original version in German language

Subject of approval: fischer concrete screw ULTRACUT FBS II for the temporary fastening of building site equipment

European Technical Assessment. ETA-14/0426 of 15 December English translation prepared by DIBt - Original version in German language

PURE 150-PRO EPOXY ADHESIVE ANCHOR

Powers Trak-It XH and HD nails for gas actuated tools C4 and C5

HUD-1 Universal anchor

PURE150-PRO CHEMICAL ANCHOR

4isofast Product code Page

ITB TECHNICAL APPROVAL AT /2011

Anchor type Base material Approvals Application. Lightweight concrete Aerated concrete. Uncracked concrete. Solid brick masonry

PEC-TA Cast-in Channels and Bolts. Certified German quality for high-end fixing solutions. Advantages of using PEC Cast-in Channels.

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

(English language translation, the original version is in French language) fischer Anchor bolt EXA

Klaus-Fischer-Straße Waldachtal DEUTSCHLAND EAD This version replaces ETA-07/0025 issued on 14 May 2018

DYNABOLT PLUS ANCHORS DYNABOLT PLUS. Anchor Details. Installation Ramset Regions. Site Map. Home Page. Performance. Next Page. Date of Issue: 9/98

WELDA FASTENING PLATES

Multi-Set II Drop-In Anchors

Codes: INCO, INSI, INPISANIN, INPINZANI. Reference: FT INDE-en Date: 23/03/18 Revision: 7 Page: 1 of 6 IN-CO IN-HE IN-SI CHARACTERISTICS

HUD-1 Plastic anchor Economical universal plastic anchor

Umbrella Inserts and Stubby Screens

Notes. Modifications and constructional corrections arising particularly from technological development excepted.

Letter of Transmittal/Submittal

Klaus-Fischer-Straße Waldachtal DEUTSCHLAND EAD This version replaces ETA-15/0352 issued on 12 April 2016

S-BT screw-in stainless steel and carbon steel threaded studs

X-P High Performance Nail for Fastening to Concrete and Wood to Steel applications

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Wedge Type Anchors. Trubolt. Wedge Anchor ADVANTAGES

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

HALFEN Anchor channel HTA / Special screw HS

TI: Efficient self tapping fasteners into concrete without plugs

Umbrella Inserts and Stubby Screens

Large Diameter Tapcon

Cone. Bolt. Rubber Washer. Rubber Washer. compressed / increased clamping force

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

European Technical ETA-13/1038 Assessment of 26 January 2018 General Part

CLT Cross Laminated Timber

Statement for nail plate LL13 Combi

The Quick, Economical Method to Secure Hurricane Protection

European Technical Assessment. ETA-12/0056 of General Part. Technical Assessment Body issuing the ETA:

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

Hollo Set Drop-In Anchors

Façade Solution. Produces façade & cassette solutions

LENGTH IDENTIFICATION

Tech Guide. Screw Anchor Performance Why use a screw anchor? Ease in installation

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

Hilti X-BT Threaded Fastener Specification. Supplement 02/2012. X-BT threaded fasteners for use in nuclear power plants

European Technical Assessment ETA-04/0038 English translation prepared by DIBt. Page 2 of July 2016

TECHNICAL MANUAL. HPM Rebar Anchor Bolt Easy and Fast Bolted Connections

European Technical Approval ETA-10/0182

TECH SHEET PEM - REF / TESTING CLINCH PERFORMANCE. SUBJECT: Testing clinch performance of self-clinching fasteners.

Z January 2017

European Technical Assessment ETA 15/0029 of 12/06/2017

English translation authorized by DIBt Original version in German language

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

BX 3 system: fasteners for Interior Finishing, Mechanical and Electrical and Building Construction applications

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

European Technical Assessment. ETA-18/0045 of 22 February English translation prepared by DIBt - Original version in German language

REISSER-Schraubentechnik GmbH Fritz-Müller-Straße Ingelfingen-Criesbach DEUTSCHLAND

Screw selecting guide for Norex & Noroc panels installation (metal screw)

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

fischer Test Report Fixing Tests for Fastfloor and Hollowcore Units

European Technical Assessment ETA-17/1005 of

fischer DUOTEC NEW Easy to install nylon toggle for high loads in all panel building materials

The Saddle Rack. For Power And Communication Cables

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

BUILT BY AMERICA. CONNECTED WORLDWIDE.

English translation authorized by DIBt Original version in German language

Unicon QwikFoot and QwikFix Threaded Inserts. Design Guide

concrete Apolo MEA Befestigungssysteme GmbH Industriestraße Aichach DEUTSCHLAND Apolo MEA Befestigungssysteme GmbH, Plant2 Germany

European Technical Assessment. ETA-16/0902 of 17 March English translation prepared by DIBt - Original version in German language.

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

POWER-Skru Large Diameter Concrete Screw

Fosroc International Limited Drayton Manor Business Park Coles Road TAMWORTH STAFFORDSHIRE; B78 3XN GROSSBRITANNIEN EAD

Using Hilti powderactuated. to install suspended metal-framed gypsum board ceilings. The application. Selection of fasteners.

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

Wash basin and urinal fixings Complete fixing sets.

European Technical Approval ETA-10/0413

European Technical Assessment. ETA-18/0861 of 12 November English translation prepared by DIBt - Original version in German language

Baltic State Price-list Concrete & Timber Work fasteners

STRUCTURAL ATTACHMENTS

Transcription:

HK HK I Anchor version Benefits - well proven - small drill bit diameter - for fixing in cracked concrete, redundant fastening only, e.g. suspended ceilings a ) Redundant fastening only Approvals / certificates Description Authority / Laboratory No. / date of issue European technical approval DIBt ETA-04/0043, 2010-06-30 ire test report DIBt ETA-04/0043, 2010-06-30 Assessment report (fire) warringtonfire W 166402 / 2007-10-26 All data given in this section for HK Ceiling anchor according ETA-04/0043, issue 2010-06-30. The anchor is to be used only for multiple use for non-structural applications. Basic loading data (for a single anchor) All data in this section applies to - Correct setting (see setting instruction) - No edge distance and spacing influence. - Concrete C 20/25, f ck,cube = 25 N/mm² to C50/60, f ck,cube = 60 N/mm² - Anchors in multiple use Characteristic resistance, all load directions (carbon steel) HK6 H HK8 Resistance Rk [kn] 2,0 5,0 5,0 (stainless steel, HCR) HK6 -R /-HCR H -R /-HCR HK8 -R /-HCR Resistance Rk [kn] 1,5 3,0 5,0 for all load directions (tension, shear and combined tension and shear loads) 316 09 / 2012

Design resistance, all load directions (carbon steel) HK6 H HK8 Resistance Rd [kn] 1,1 2,0 2,0 (stainless steel, HCR) HK6 -R /-HCR H -R /-HCR HK8 -R /-HCR Resistance Rd [kn] 0,6 1,2 2,3 for all load directions (tension, shear and combined tension and shear loads) Recommended loads, all load directions (carbon steel) HK6 H HK8 Resistance rec b) [kn] 0,8 1,4 1,4 (stainless steel, HCR) HK6 -R /-HCR H -R /-HCR HK8 -R /-HCR Resistance rec b) [kn] 0,4 0,8 1,6 With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national regulations. b) for all load directions (tension, shear and combined tension and shear loads) Special case: Groups of n=2 and/or n=4 anchors with small spacing The basic loading data for a single anchor is valid for one fixing point. ixing points can be: c cr Single anchors group of 2 anchors group of 4 anchors 100 - single anchors, or - groups of 2 anchors with s 1 60 mm or - groups of 4 anchors with s 1 100 mm and s 2 100 mm c cr 60 100 Requirements for multiple use The definition of multiple use according to Member States is given in the ETAG 001 Part six, Annex 1. In Absence of a definition by a Member State the following default values may be taken Minimum number of fixing points Minimum number of anchors per fixing point Maximum design load of action N Sd per fixing point 3 1 2 kn 4 1 3 kn The value for maximum design load of actions per fastening point N Sd is valid in general that means all fastening points are considered in the design of the redundant structural system. The value N Sd may be increased if the failure of one (= most unfavourable) fixing point is taken into account in the design (serviceability and ultimate limit state) of the structural system e.g. suspended ceiling. 09 / 2012 317

Materials Mechanical properties of HK (carbon steel) HK6 H HK8 Char. bending resistance M0 Rk,s [Nm] 3,6 7,7 18 Partial material safety factor Ms = 1,25. (stainless steel, HCR) HK6 -R /-HCR H -R /-HCR HK8 -R /-HCR Char. bending resistance M0 Rk,s [Nm] 4,0 8,4 20,6 Partial material safety factor Ms = 1,5. Material quality of HK Part Marking Material Anchor HK6 Anchor H Anchor HK8 Anchor HK6 -R Anchor H -R Anchor HK8 -R Anchor HK6 -HCR Anchor H -HCR Anchor HK8 -HCR K6 K8 K6E E K8E K6X X K8X K6C C K8C galvanised steel 5 m stainless steel, 1.4401or 1.4404 stainless steel, 1.4571 high corrosion resistant steel, 1.4529 or 1.4565 Anchor dimension h 1 l th l p l 1 d a 318 09 / 2012

HK6 H M6/t fix M8/t fix M6/4 M6/t fix M8/t fix I M6 I M8 Thread size external external external external external internal internal M6 M8 M6 M6 M8 M6 M8 Length of thread l th [mm] 5 50 5 5 5 12 12 Length of projection l p [mm] t fix + 7 11 300 300 - - Diameter of sleeve d a [mm] - - - - 8 10 Length of sleeve l 1 [mm] - - - - 15 15 HK8 I M8 I M10 I M12 I M8/M10 Thread size internal internal internal internal M8 M10 M12 M8/M10 Diameter of sleeve d a [mm] 10 12 14 12 Length of sleeve l 1 [mm] 15 20 20 25 Setting Recommended installation equipment HK6 HKL HK8 Rotary hammer TE 2 TE 16 Stop drill bit SDS 2 SDS 3 Setting tool HSM / HSM I HSM 8 / HSM 8 I Other tools Setting instruction Setting of HK blow out pump with hand setting tool b) with machine setting tool Setting of HK-I with hand setting tool b) with machine setting tool 09 / 2012 319

Setting details h 1 h 1 l th l p l 1 SDS 2 d a Stop drill bit Setting tool HK6 HK L M6/t fix M8/t fix M6/4 M6/t fix M8/t fix I M6 I M8 Stop drill bit SDS 1 SDS 2 Depth of drill hole b) h 1 [mm] 32 42 Nominal diameter of drill bit d 0 [mm] 6 6 Setting tool HSM 6 / HSM 8 / HSM 6 / 4 HSM 6 / HSM 8 / t fix t fix t fix t fix HSM I M6 HSM I M8 Clearance hole d f [mm] 7 9 7 7 9 9 12 Max. torque moment T max [Nm] 5 5 HK8 I M8 I M10 I M12 I M8/M10 Stop drill bit SDS 3 Depth of drill hole b) h 1 [mm] 43 Nominal diameter of drill bit d 0 [mm] 8 Setting tool HSM 8 I HSM 8 I HSM 8 I HSM 8 I M8 M10 M12 M8 Clearance hole d f [mm] 12 14 16 14 Max. torque moment T max [Nm] 10 In case of through stetting choose stop drill bit with appropriate length b) Use stop drill bit to ensure correct depth of bore hole 320 09 / 2012

Base material thickness, anchor spacing and edge distance HK6 HKL HK8 Minimum member thickness h min [mm] 80 Effective anchorage depth h ef [mm] 26 36 36 Critical spacing s cr [mm] 200 Critical edge distance c cr [mm] 150 The critical spacing (critical edge distance) shall be kept. Smaller spacing (edge distance) than critical spacing (critical edge distance) are not covered by the design method. 09 / 2012 321