Low cost of ownership. Input QM5 QM5H

Similar documents
<100µA (with 4 or fewer modules). For other configurations, contact sales for details.

Vega Series (Vega-Lite)

Low cost of ownership. Input Frequency. Adjustment Range V V V. Channel 3 3

NV W Configurable power supply. NV-300. Input. How To Create A Product Description. QUICK SELECTOR - example configurations

Inrush Current (cold start)

Low cost of ownership. Adjustment Range V V V. Channel V / 15A 2.7V / 15A 3.3V / 15A Omit 5V / 10A 10 Omit 5V / 8A 8 Omit

NV-350 / NV W W Modular power supply. Features Benefits Input How To Create A Product Description NV3 Converter NV3 3 NV7 7

Vega Series. 450W - 900W Modular power supply. Vega Series. Input. How To Create A Product Description V4 F S S F

Input Frequency. Input Fuse 6.3A Fast acting (not user accessible) Inrush Current 15A typical at 25 C and 230Vac (cold start) Earth Leakage Current

Operating temperature (2, 3, 5) C -20 C to +70 C ( see derating curves) Storage temperature C -40 C to +85 C

NV /180/200 Watts AC/DC Flexible Power Solution

NV-350 / NV Watts Modular power solution With up to 1450W peak rating for 10 seconds

DRF Series. 120W - 480W Single Output: 24V 180W - 720W Peak Power DIN Rail Mount Power Supplies. DRF Series 1. Specifications

Vega Series. 450W - 900W Modular power supply. Vega Series. Input. How To Create A Product Description V4 F S S F

CM4 Series. Conduction cooled. Modular Power Supply. CM4 Series 1. Specification

QS Series. Up to 1200W, Single Output, Medical and Industrial Power supply. Multiple output units available, see TDK-Lambda s QM Series.

HFE2500 Series. 2500W 1U Hot Swap Front End Power Supplies. HFE2500 Series 1. Key Market Segments & Applications. HFE2500 Features and Benefits

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

Output Power (W) Industry Leading Performance. Fuse

Vega Series 450, 650 & 900 Watts Modular Power Solution

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

Industrial Serie +600S

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

General. Environmental. EMC & Safety

C B. Models. Models 2MOPP

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

AC/DC Modular Power Supply Series APPLICATION NOTES

Electrical Specifications

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

Output Voltage (Vfan) & Current

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

MB120S 120W Single Output Medical Series

Voltage Adjustment. Load Regulation

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

General. Environmental. EMC & Safety

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Doc. EA Model Number:

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Electrical Specifications

Watts HCP Series

PDAM500 Series 500W Power Supply

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

TB65 65W Single Output Test and Measurement/Industrial Series

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

LB115S 115W Single Output

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Output Voltage* (nom.)(adjustable)

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

VOF XX - XXX - X

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

CCH400 & CCH600 Series

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

HEC-45LTN-45PFAS Rev A

AC/DC Modular Power Supply Series APPLICATION NOTES

150 Watt Industrial (WLT)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

Power Supplies. SHP Series: Heavy Duty Modular Power Supplies

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Metal Case Power Supplies

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

TE60 60W Single Output External Power Test & Measurement/Industrial Series

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

NFF Series. CoolX600 NFF Series Cool. Patent Pending Resonant Technology. NFF Series; No Fan Featured

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

TE W Single Output External Power Test & Measurement/Industrial Series

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

TE90 90W Single Output External Power Test & Measurement/Industrial Series

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

HEC-30/35LTA-33TDAA Rev A

HEC-100RTA-48QSCA Rev A1.0

Transcription:

QM5 eries www.uk.tdk-lambda.com/qm5 Medical Industrial Test Broadcast Comms Renewable 700W / 1200W Modular power supply Features BF ready medical isolation (MOPP) Low speed, low audible noise fan Up to 12 outputs PMBus communication option 7 year warranty Benefits Eases design into systems (including BF) Enhanced patient / user experience Eliminates need for additional supplies Remote monitoring and control Low cost of ownership Input QM5 QM5H power 700W 800W 700W 1200W Input voltage 90-264Vac 180-264Vac 90-264Vac 180-264Vac Frequency 47-63 Hz (440Hz with reduced PFC) Input fuses 16A / 250Vac HBC Fast acting (not user accessible) in both Live and Neutral lines (single fusing optional) Inrush current <40A at 25 C and 264Vac (cold start) Leakage current ee for details Touch current <100µA (with 4 or fewer modules). For other configurations, contact sales for details. Power factor > 0.95 (at 100% load) Isolation Input to output Reinforced 2 x MOPPs (3rd edition 60601) 4kVac, 5.7kVdc type tested to 4kVac (equivalent to 5.7kVdc), production tested to 4.3kVdc. Input to earth Basic 1 x MOPP, 1.5kVac to earth Basic 1 x MOPP, 1.5kVac to output Basic 200Vdc The extensive range of output modules and options make it possible to achieve almost any combination of Volts and Amps. You can create your own QM configuration online at https://config.emea.tdk-lambda.com/. This method checks your configuration and offers the optimum solution. Alternatively, you can do this manually by using the guide below. 1. Calculate total output power to select the appropriate converter, then select required Cooling, Connection, Leakage Current and Controls/ ignals from the following table: QM5 F D L T5H Converter 5 slots wide Cooling Input Connection Input fuse QM5 700W low line, 800W high line QM5H 700W low line, 1200W high line F R C I D E Variable speed Forward air - standard Reverse air (contact sales for details) Customer air - no fan (contact sales for details) crew IEC320 Dual AC fuses ingle AC fuse in Live line (contact sales for details) blank none E5L 5V / 250mA, Enable E5H 5V / 2A, 5V / 250mA, Enable tandby T5L 5V / 250mA, Inhibit / ignals T5H 5V / 2A, 5V / 250mA, Inhibit P5H 5V / 2A, see PMBus app note see specification page for details Leakage Current (max at 264Vac, 63Hz) L 300µA R 150µA (contact sales for details) 2. elect Modules using the output voltages tables and the module specifications. 3. Contact TDK-Lambda to validate configuration and issue a part number. QM5 eries 1

Possible s - see individual module data for full specifications Module name lots used voltage range Maximum Current Maximum Power DM (ch2) 1 of 2 outputs in single slot 2.8V - 3.8V 10A 33W B 1 slot 3.3V - 3.74V 37A 138W DM (ch2) 1 of 2 outputs in single slot 4.25V - 5.75V 10A 50W B 1 5V - 5.5V 30A 150W C 2 5V - 5.5V 60A 300W ZD 3 5V - 5.3V 80A 400W ZF 4 5V - 5.3V 110A 550W YC 2 6.6V - 7.48V 37A 276W YC 2 10V - 11V 30A 300W YF 4 10V - 11V 60A 600W DH (ch1 or ch2) 1 of 2 outputs in single slot 10.2V - 13.8V 10A 120W DM (ch1) 1 of 2 outputs in single slot 11.9V - 16.1V 10A 120W DM (ch2) 1 of 2 outputs in single slot 11.9V - 16.1V 8.3A 100W B 1 12V - 13.2V 25A 300W C 2 12V - 13.2V 50A 600W ZD 3 12V - 12.8V 65A 780W ZF 4 12V - 12.8V 85A 1020W B 1 15V - 16.5V 20A 300W ZC 2 15V - 16V 34A 510W DH (ch1 or ch2) 1 of 2 outputs in single slot 20.4V - 27.6V 5A 120W YB 1 20.4V - 27.6V 9.8A 200W DM (ch1) 1 of 2 outputs in single slot 20.8V - 28.2V 5A 120W DM (ch2) 1 of 2 outputs in single slot 23.5V - 24.5V 4.16A 100W B 1 24V - 26.4V 12.5A 300W C 2 24V - 26.4V 25A 600W ZD 3 24V - 25.6V 30A 720W YF 4 24V - 26.4V 50A 1200W B 1 28V - 30.8V 10.7A 300W ZC 2 28V - 29.9V 18A 504W YC 2 30V - 33V 20A 600W YB 1 40.8V - 55.2V 4.9A 200W YC 2 48V - 52.8V 12.5A 600W YF 4 48V - 52.8V 25A 1200W YC 2 56V - 61.6V 10.7A 600W 2 QM5 eries

pecification Turn on time 2s max at 90Vac (180Vac for 1200W) and 100% rated output power Efficiency up to 91% 240Vac & above 50% rated power, configuration dependent Hold up 16ms min 10ms min at 700W output power. 1 cycle ride-through option available, contact sales for details. at 1200W output power converter protection shuts down all outputs (except standby supplies) and fan, auto restarts. hutdown temperature varies according to ambient, output power and input voltage. Environment Temperature -20 C to 70 C operational, -40 C to 70 C storage (max 12 months). 65 C for IEC inlet Derating 50 C to 70 C derate total output power and each output current by 2.5% per C Low temperature startup -40 C Humidity 5-95% RH non condensing ±3 x 30g shocks in each plane, total 18 shocks hock 30g shock = 11ms (+/-0.5msec), half sine Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JI C0041-1987. Conforms to MIL-TD-810G, Method 516.6, Pro I, IV ingle axis 10-500 Hz at 2g (sweep and endurance at resonance) in all 3 planes Vibration Conforms to EN60068-2-6, IEC68-2-6 Conforms to MIL-TD-810G, Method 514.6, Pro I Altitude 5000 metres operational, 5000 metres storage/transportation Pollution Degree 2, Material group IIIb IP Rating IPX0 Emissions EN61000-6-3:2007, EN60601-1-2:2015 - see application notes for best installation practice Radiated electric field EN55011, EN55032 (as per CIPR.11/32) Class B, FCC47 part 15 subpart B - L leakage current variants (Units with R type leakage current option achieve Class A) Conducted emissions EN55011, EN55032 (as per CIPR.11/32) Class B, FCC47 part 15 subpart B - L leakage current variants (Units with R type leakage current option achieve Class A) Conducted harmonics EN61000-3-2 Class A and Class C Flicker EN61000-3-3 Compliant - d max only Immunity EN61000-6-2:2005, EN60601-1-2:2015 - see application notes for best installation practice Electrostatic discharge EN61000-4-2 Level 4 F type cooling only Level 3 on I/O / signal pins Electromagnetic field EN61000-4-3 Level 3 Proximity fields, EN60601-1-2, Levels as defined in standard, Criteria A A Fast / burst transient EN61000-4-4 Level 4 Tested at 5kHz and 100kHz A urge immunity EN61000-4-5 Level 3 A Conducted RF immunity EN61000-4-6 Level 3 A Power frequency magnetic field EN61000-4-8 Level 4 A Voltage dips, variations, interruptions EN61000-4-11 Class 3 Criteria B for 5s and 1 cycle interruptions A Voltage sags emi F-47 compliant above 180Vac input Ring wave EN61000-4-12 Level 3 A ANI C62.41 Level 2 A Voltage fluctuations EN61000-4-14 Class 3 ee EMC report for full details. A Criteria A Approvals / Accreditations IEC/EN 60950-1, UL60950-1 / CA 22.2 No 60950-1 File E135494 IEC/EN 60601-1, UL/CA 60601-1, ANI/AAMI E60601-1 CAN/CA-C22.2 No 60601-1 File E349607 IEC/EN 61010-1 Results included in 60950 report CE Mark (EN60950-1) Low Voltage Directive (LVD) CB certificate and Report available on request Designed and manufactured under the control of IO9001 and IO13485 (including risk management). QM5 eries 3

tandby / ignals Maximum power per channel see table below PU inhibit (Txx type) or enable (Exx type), AC Good Option type Available Voltages (at PU signal connector) V tandby 1 tandby 2 Max Current Power V Max Current Power PU on/off E5L 5V 250mA 1.25W not available Enable E5H 5V 250mA 1.25W 5V 2A 10W Enable T5L 5V 250mA 1.25W not available Inhibit T5H 5V 250mA 1.25W 5V 2A 10W Inhibit Pin 5L 5H 1 tandby 2 + Do not connect 2 tandby 2-3 tandby 1 + tandby 1 + 4 tandby 1 - tandby 1-5 PU on/off+ PU on/off+ 6 PU on/off- PU on/off- 7 AC fail Out AC fail Out 8 AC fail Rtn AC fail Rtn 9 10 Do not connect 1 2 9 10 pecification tandby 1 tandby 2 Rise time TBC <30ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot TBC TBC Load type dependent, no overshoot at full load with resistive load Ripple and noise <1% <1% pk-pk, using 20MHz bandwidth Voltage setting accuracy <3% <3% of set voltage Remote sense No No Minimum load 0W 0W on any output Temperature coefficient TBC TBC of rated voltage per C Load regulation <1.5% <1% for 0-100% load change Line regulation <0.1% <0.1% for 90-264Vac input change Cross regulation TBC TBC for 100% load change on any output Transient deviation <5% <5% of set voltage for 25-50% load change Recovery 1ms 1ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, output shuts down, cycle ac to reset Over current protection Constant Current Auto recovers hort circuit protection Constant Current Auto recovers 4 QM5 eries

tandby / ignals - PMBus (P5H) tandby supply Further details 5V / 2A PMBus control of power supply fan speed and fail warning erial number, date of manufacture, run time, on/off power cycles ee QM range application note, PMBus section AVAILABLE OUTPUT VOLTAGE (at PU signal connector) Option type V tandby Max Current Power P5H 5V 2A 10W PU on/off see PMBus application note Pin P5H option 1 tandby + 2 tandby - 3 Do not connect 4 Fan fail 5 Address 0 6 Address 1 7 Address 2 8 Address 3 9 CL - Clock 10 DA - Data 11 Control line in 12 GND 1 2 11 12 pecification tandby Rise time TBC (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot TBC Load type dependent, no overshoot at full load with resistive load Ripple and noise <1% pk-pk, using 20MHz bandwidth Voltage setting accuracy <3% of set voltage Remote sense No Minimum load 0W on any output Load regulation <1.5% for 0-100% load change Cross regulation TBC for 100% load change on any output Transient deviation <5% of set voltage for 25-50% load change Recovery 1ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, output shuts down, cycle ac to reset Over current protection Constant current Auto recovers hort circuit protection Constant current Auto recovers QM5 eries 5

DH Module - single slot width, 2 output channels Maximum module power 200W Total power from channel 1 + channel 2 Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) V1 Adjustment Range (Volts) Current power V2 Adjustment Range (Volts) Current power 10.2-13.8 10A 120W 10.2 a - 13.8 10A 120W 20.4-27.6 5A 120W 20.4 c - 27.6 5A 120W 20.4-27.6 5A 120W CH1 + CH1 0V 10 9 V ADJ 2 1 CH2 + CH2 0V Pin Connection 1 Do not connect 2 3 Module good collector 4 Module good emitter 5 Module inhibit anode 6 Module inhibit cathode 7 8 Do not connect 9 10 Channel 1 and channel 2 of DH are both adjusted by single potentiometer. The V2 set = V2max x V1set / V1max a, b, c, d - for output voltages below 10.8V(a), 13.5V(b), 21.6V(c) or 24.4V(d), a Minimum load of 1W must be applied to channel 1 pecification Rise time <50ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot zero at full load with resistive load. Load type dependent, <7% overshoot with capacitive load Ripple and noise 0 C - 70 C 1.5% -20 C - 0 C 2.25% pk-pk, using 20MHz bandwidth Voltage setting accuracy <1% of set voltage (3% for channel 2) Remote sense No Minimum load 0W Except for notes a, b, c and d above. Load regulation <6% for 5-100% load change Cross regulation 3% for 5-100% load change on any output Transient deviation <4% of set voltage for 50% load change (above 25% load) Recovery 3ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down (both outputs), cycle ac to restart. Module current protection Hiccup hort circuit protection Hiccup huts down both outputs, auto recovers. Maximum capacitive load 1000µF/A 750µF/A for outputs above 20V Protects channel 1 and channel 2, shuts down both outputs, auto-recovers when fault clears. Module protection shuts down both outputs, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Choose your required channel 1 and channel 2 voltages (from the table above) For example, if you need 12V / 10A and 24V / 3A, you would choose 12/24DH as your required module. V1 / V2 DH 1 required voltage crew terminal 2 required voltage 6 QM5 eries

DM Module - single slot width, 1 or 2 output channels Maximum module power 200W Total power from channel 1 + channel 2 Maximum power per channel see table below Remote sense (channels 1 & 2), channel 1 good, channel 2 good, Channel 2 inhibit, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) V1 Adjustment Range (Volts) Current power V2 Adjustment Range (Volts) Current power Channel 1 unused 2.8-3.8 10A 33W 4.25-5.75 10A 50W 11.9-16.1 10A 120W 20.8-28.2 5A 120W Channel 2 unused 2.8-3.8 10A 35W 11.9-16.1 10A 120W 4.25-5.75 10A 50W 11.9-16.1 8.3A 100W 23.5-24.5 4.16A 100W 20.8-28.2 5A 120W 2.8-3.8 10A 35W 4.25-5.75 10A 50W 21.6-28.2 5A 120W 23.5-24.5 4.16A 100W 12 2 CH1 + CH1 0V 11 CH1 V ADJ CH2 1 V ADJ CH2 + CH2 0V Pin Connection 1 Ch2 sense + 2 Ch2 sense - 3 Ch2 inhibit anode 4 Ch2 inhibit cathode 5 Ch2 good collector 6 Ch2 good emitter 7 Ch1 good collector 8 Ch1 good emitter 9 Module inhibit anode 10 Module inhibit cathode 11 Ch1 sense + 12 Ch1 sense - pecification Ch1 Ch2 Rise time <20ms <50ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% <5% Load type dependent, no overshoot at full load with resistive load Ripple and noise pk-pk, using 20MHz bandwidth 0 C - 70 C 1.5% 75mV 1.5% for ch2 outputs >10V, 2% for outputs 11-17V -20 C - 0 C 2.25% 75mV 2% for ch2 outputs >10V, 2.5% for outputs 11-17V Voltage setting accuracy <1% <1% of set voltage Remote sense 0.5V (voltage at the output terminals must be within the specified adjustment range) Minimum load 0W Refer to application note for details. Temperature coefficient TBC TBC of rated voltage per C Load regulation max of 50mV or <1% of set voltage for 0-100% load change Cross regulation 1.5% for 100% load change on any output Transient deviation <4% <5% of set voltage for 50% load change (above 25% load). 250mV for outputs below 5V Recovery 3ms 7ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down (both outputs), cycle ac to restart. Over current protection Hiccup Constant current Ch1 protection shuts down both outputs. hort circuit protection Hiccup Constant current Ch1 protection shuts down both outputs. Refer to application note for details. Maximum capacitive load 500µF/A 500µF/A Ch1 protection shuts down both outputs, cycle ac to restart. Ch2 protection shuts down ch2 only, auto recovers when fault clears. hutdown temperature varies according to ambient, output power and input voltage. Choose your required channel 1 and channel 2 voltages (from the table above) For example, if you need 12V / 10A and 3.3V / 10A, you would choose 12/3.3DM as your required module. V1 / V2 DM 1 required voltage (enter 0 if not needed) crew terminal 2 required voltage (enter 0 if not needed) QM5 eries 7

B Module - single slot width, 1 output channel Maximum power per channel see table below Remote sense, module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 3.3-3.63 37A 122W 5-5.5 30A 150W 12-13.2 25A 300W 15-16.5 20A 300W 24-26.4 12.5A 300W 28-30.8 10.7A 300W 10 9 CH1 + CH1 0v V ADJ Pin Connection 1 Do not connect 2 3 Module good collector 4 Module good emitter 5 Module inhibit anode 6 Module inhibit cathode 7 Remote sense + 8 Remote sense - 9 Do not connect 10 2 1 pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise max of pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1% or 50mV TBC -20 C - 0 C, >20% load 1.5% or 75mV 0 C - 70 C, 20% load 1.5% or 75mV -20 C - 0 C, 20% load 2.5% or 125mV Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <1% for 0-100% load change Cross regulation 0.1% (5mV for outputs below 5V) for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) 250mV for outputs below 5V Recovery 1ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers after removal of load hort circuit protection Indefinitely protected Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load 1000µF/A 750µF/A for 24-26.4V module, 500µF/A for 28-30.8V module. Choose your required output voltage (from the table above) For example, if you need 12.2V / 24.5A, you would choose 12.2B as your required module. V1 B Required output voltage crew terminal 8 QM5 eries

C Module - two slots width, 1 output channel Maximum power per channel see table below Remote sense, module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 5-5.5 60A 300W 12-13.2 50A 600W 24-26.4 25A 600W CH1 + CH1 0v Pin Connection 1 Do not connect 2 3 Module good collector 4 Module good emitter 5 Module inhibit anode 6 Module inhibit cathode 7 Remote sense + 8 Remote sense - 9 Do not connect 10 10 9 V ADJ 2 1 pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise V out <10V V out >10V pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1.5% 1% -20 C - 0 C, >20% load 3% 2% 0 C - 70 C, 20% load TBC TBC -20 C - 0 C, 20% load TBC TBC Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <1% for 0-100% load change Cross regulation 0.1% for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) Recovery 1ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers after removal of load hort circuit protection Indefinitely protected Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load TBC Choose your required output voltage (from the table above) For example, if you need 12.2V / 49A, you would choose 12.2C as your required module. V1 C Required output voltage crew terminal QM5 eries 9

YB Module - single slot width, 1 output channel Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 20.4-27.6 9.8A 200W 40.8-55.2 4.9A 200W Ch1 + Pin Connection 1 Do not connect 2 3 Module good collector 4 Module good emitter 5 Module inhibit anode 6 Module inhibit cathode 7 Do not connect 8 9 10 Ch1 0V pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot zero at full load with resistive load. Load type dependent, <7% overshoot with capacitive load Ripple and noise pk-pk, using 20MHz bandwidth 0 C - 70 C 1.5% -20 C - 0 C 2.25% Voltage setting accuracy <2% of set voltage Remote sense No Minimum load 0W Load regulation <6% for 5-100% load change Cross regulation <1% for 100% load change on any output Transient deviation <8% of set voltage for 50% load change (above 25% load) Recovery 5ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers hort circuit protection Hiccup Auto recovers. Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load TBC Choose your required output voltage (from the table above) For example, if you need 41V / 4A, you would choose 41YB as your required module. V1 YB Required output voltage crew terminal 10 QM5 eries

YC Module - two slots width, 1 output channel Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 6.6-7.48 37A 276W 10-11 30A 300W 30-33 20A 600W 48-52.8 12.5A 600W Ch1 + Ch1 0V ee application notes for signal details 56-61.6 10.7A 600W pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1% -20 C - 0 C, >20% load 1.5% 0 C - 70 C, 20% load 1.5% -20 C - 0 C, 20% load 2.5% Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <1% for 0-100% load change Cross regulation 0.1% (10mV for outputs below 10V) for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) Recovery 1ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers hort circuit protection Indefinitely protected Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load 1000µF/A 350µF/A above 48V Choose your required output voltage (from the table above) For example, if you need 58V / 10A, you would choose 58YC as your required module. V1 YC Required output voltage crew terminal QM5 eries 11

YF Module - four slots width, 1 output channel Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 10-11 60A 600W 24-26.4 50A 1200W 48-52.8 25A 1200W Ch1 + Ch1 0V ee application notes for signal details pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise V out <20V V out >20V pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1.5% 1% -20 C - 0 C, >20% load 3% 2% 0 C - 70 C, 20% load TBC TBC -20 C - 0 C, 20% load TBC TBC Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <1% for 0-100% load change Cross regulation 0.1% for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) Recovery 1ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers hort circuit protection Indefinitely protected Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load 1000µF/A (10YF), 750µF/A (24YF), 600µF/A (48YF) Choose your required output voltage (from the table above) For example, if you need 48V / 25A, you would choose 48YF as your required module. V1 YF Required output voltage crew terminal 12 QM5 eries

ZC Module - two slots width, 1 output channel Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 15-16.0 34A 510W 28-29.9 18A 504W Ch1 + Ch1 0V ee application notes for signal details pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1% -20 C - 0 C, >20% load 1.5% 0 C - 70 C, 20% load 1.5% -20 C - 0 C, 20% load 2.5% Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <3% for 0-100% load change Cross regulation 0.1% for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) Recovery 30ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers after removal of load hort circuit protection Indefinitely protected Maximum capacitive load TBC Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Choose your required output voltage (from the table above) For example, if you need 15V / 36A, you would choose 15ZC as your required module. V1 ZC Required output voltage crew terminal QM5 eries 13

ZD Module - three slots width, 1 output channel Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) at PU output terminal Current power 5-5.3 80A 400W 12-12.8 65A 780W 24-25.6 30A 720W Ch1 + Ch1 0V ee application notes for signal details pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise V out <10V V out >10V pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1.5% 1% -20 C - 0 C, >20% load 3% 2% 0 C - 70 C, 20% load TBC TBC -20 C - 0 C, 20% load TBC TBC Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <3.5% for 1-100% load change (<2.5% for 5-5.3V output) Cross regulation 0.1% for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) Recovery 30ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers after removal of load hort circuit protection Indefinitely protected Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load 1000µF/A For outputs above 6V, value TBC. Choose your required output voltage (from the table above) For example, if you need 48V / 16A, you would choose 48ZD as your required module. V1 ZD Required output voltage crew terminal 14 QM5 eries

ZF Module - four slots width, 1 output channel Maximum power per channel see table below Module good, module inhibit AVAILABLE OUTPUT VOLTAGE (at PU output terminals) Adjustment Range (Volts) Current power 5-5.3 110A 550W 12-12.8 85A 1020W Ch1 + Ch1 0V ee application notes for signal details pecification Rise time <75ms (with resistive load) to 90% of voltage, monotonic rise above 10% Turn on overshoot <5% Load type dependent Ripple and noise V out <10V V out >10V pk-pk, using 20MHz bandwidth 0 C - 70 C, >20% load 1% 1.5% -20 C - 0 C, >20% load 2% 3% 0 C - 70 C, 20% load TBC TBC -20 C - 0 C, 20% load TBC TBC Voltage setting accuracy <1% of set voltage Remote sense 0.5V (voltage at the output terminals must remain within the adjustment range specified above) Minimum load 0W Load regulation <3.5% for 1-100% load change (<2.5% for 5-5.3V output) Cross regulation 0.1% for 100% load change on any output Transient deviation <5% of set voltage for 50% load change (above 25% load) Recovery 30ms for recovery to 1% or 100mV of set voltage Over voltage protection Latching, module shuts down, cycle ac to restart. Over current protection Hiccup Auto recovers after removal of load hort circuit protection Indefinitely protected Module protection shuts down output, cycle ac to restart. hutdown temperature varies according to ambient, output power and input voltage. Maximum capacitive load 1000µF/A Choose your required output voltage (from the table above) For example, if you need 12V / 90A, you would choose 12ZF as your required module. V1 ZF Required output voltage crew terminal QM5 eries 15

270 MAX (INCLUDING ENDCAP) 127 MAX 21.20 175.00 21.3 268 MAX 21.20 175.00 127 MAX 21.3 21.20 205.00 90.50 17.60 15.00 30.00 63.3 MAX 14.40 15.00 17.60 90.50 30.00 63.3 MAX 14.50 21.20 4 OFF IDE FIXING ARE ECONDARY FIXING AND HOULD BE UED IN CONJUNCTION WITH OTHER FIXING / UPPORT 205.00 L N TERMINAL COVER REMOVED PRE BOTH TAB THEN LEVER FORWARD TO REMOVE. REVERE TO RE-FIT Units with factory fitted fan ( F or R type cooling) ACCE TO CREW TERMINAL BY REMOVING COVER 285 MAX (TO CONNECTOR) 280 MAX (TO ENDCAP) 21.20 175.00 127 MAX 21.25 90.50 17.60 15.00 30.00 63.3 MAX 23.50 4 OFF IDE FIXING ARE ECONDARY FIXING AND HOULD BE UEDIN CONJUNCTION WITH OTHER FIXING / UPPORT 21.20 205.00 L N Units with IEC inlet ( I type Input Connection) IEC CONNECTOR 4 OFF IDE FIXING ARE ECONDARY FIXING AND HOULD BE UED IN CONJUNCTION WITH OTHER FIXING / UPPORT L N Units with Customer Air ( C type cooling) CREW TERMINAL Customer fixings. 8 holes M4. Max thread penetration:- 4.5mm 16 QM5 eries

TDK-Lambda France A 3 Avenue du Canada Parc Technopolis Bâtiment igma 91940 les Ulis France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com Italy ales Office Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com Netherlands info@nl.tdk-lambda.com www.nl.tdk-lambda.com TDK-Lambda Germany GmbH Karl-Bold-trasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com TDK-Lambda UK Ltd. Kingsley Avenue Ilfracombe Devon EX34 8E United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com TDK-Lambda Ltd. Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il C.I.. Commercial upport: Tel: +7 (495) 665 2627 Technical upport: Tel: +7 (812) 658 0463 info@tdk-lambda.ru www.tdk-lambda.ru Local Distribution Austria ales Office Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info@at.tdk-lambda.com www.de.tdk-lambda.com witzerland ales Office Bahnhofstrasse 50 8305 Dietlikon witzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@ch.tdk-lambda.com www.de.tdk-lambda.com Nordic ales Office Haderslevvej 36B DK-6000 Kolding Denmark Tel: +45 2911 9556 info@dk.tdk-lambda.com QM5FM_Datasheet_260323_3.0.600 www.emea.tdk-lambda.com QM5 eries 17