MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

MINI MCR-SL-UI-f(-SP)

Medium Converter FL MC 10BASE-T/FO G850

MINI-PS AC/2X15DC/1

QUINT-PS-24DC/24DC/10

MINI-PS AC/24DC/1.3

High precision measurement system for current and voltage IHC-A/B-RM01/03

QUINT-PS/ 3AC/24DC/10

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Power supply CP-D 24/1.3

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

QUINT-PS/ 3AC/24DC/40

Power supply CP-D 12/2.1

Extract from the online catalog

Power supply CP-D 24/4.2 Primary switch mode power supply

MDW-45 Converter RS RS-422/485

Power supply CP-E 24/20.0

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Switching power supplies CP range, Linear power supplies CP-L range. Content

MID energy meter B21 Single-phase energy meter, 65 A

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Power supply CP-E 24/2.5

For non-electrical quantities

QUINT-PS AC/24DC/40

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

T40B. Torque Flange. Special features. Data sheet. Overall concept

Overcurrent Protection / 7SJ45

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

T40FH. Torque flange. Special features. Data sheet

QUINT-PS/ 1AC/24DC/20

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

MINI MCR-SL-UI-I-LP-NC

Solid-State Soft Starters

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-TGD.22

Electronic timer CT-SDD.22

PHOENIX CONTACT - 09/2009

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Power supply CP-T 48/20.0 Primary switch mode power supply

CP-T range Benefits and advantages

Power supply CP-T 48/5.0 Primary switch mode power supply

C series Product brief

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-T 24/20.0 Primary switch mode power supply

CP-T range Product group picture

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Power supply CP-T 24/10.0 Primary switch mode power supply

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

Power supply CP-T 24/40.0 Primary switch mode power supply

Solid-State Relays Zero-point switching, without heatsink

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

This data sheet is only valid in association with the IL SYS INST UM E user manual.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Protection components

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

MCR-PSP MCR Threshold Value Switch, Programmable

Network Analyzer for Low-, Medium- and High-Voltage Networks

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

POINTAX 6000L2 Point Recorder

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

T22. Torque transducer. Special features. Data sheet

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

XIOC technology and networking modules

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Analog signal converters CC-E I/I

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

CP-E range Benefits and advantages

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Output of three-phase motors at 50 Hz and 400 V

Three-phase monitoring relay CM-PFS

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

PHOENIX CONTACT

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

PHOENIX CONTACT

Transcription:

PSM-ME-/-P. Short Description The rail-mountable and compact RS-485 repeater, PSM-ME-/-P, was specially developed for the high demands for use in fieldbus systems. The device is snapped onto standard EN mounting rails in the switch cabinet and supplied with 24 V. The main areas of application are: Electrical isolation/ bus segmentation Increasing system availability in the event of short circuits in bus lines Increasing the range Increasing transmission rates Extending the number of stations to n x 32 Implementing hybrid and network structures The PSM-ME-/-P repeater can be used universally in all conventional 2-wire bus systems, such as: PROFIUS MODUS RCKUS (Endress & Hauser) SUCONET-K (Moeller) UNI-TELWY (Telemecanique) DNUS (Danfoss) RS-US (Landis & Staefa) NET 2000 ( & R) INSUM () J-US (Merlin Gerin) JET-WY (Jetter) S-US (SI) and approximately 60 other proprietary bus systems The following features of the repeater are particularly outstanding: Supports all bus systems with URT/NRZ data format and 0/ bits character length Transmission rate 4.8 kbit/s to.5 Mbit/s utomatic transmit/receive changeover Integrated, connectable terminating resistors High-quality 3-way isolation ( // RS-485 // RS-485) Integrated surge voltage protection with transient discharge to the mounting rail Supply voltage of 24 V DC or C to suit the switch cabinet Convenient connection with pluggable COMICON screw terminal blocks If you have any technical questions, please contact us at: PSM-HOTLINE:+49/(0)52 35/3-9890 FX:+49/(0)52 35/3-9899 e-mail: interface-service@phoenixcontact.com Headquarters: Phoenix Contact GmbH & Co. KG Flachsmarktstraße 8 32825 lomberg Germany Phone +49-(0) 52 35-3-00 Fax +49-(0) 52 35-3-4 2 00 http://www.phoenixcontact.com

D() D() 6 D() D() D() D() D() D() 6 6 D() D() 6 D() 0V D() 0V 6 D() 0V D() 0V PSM-ME-/-P 2. pplication ased on the RS-485 standard specifying the electrical characteristics of bus interfaces, there are numerous applications for the repeater module as a result of the following reference data: Terminating resistor max. 200 m RS-485 standard (fig. 2) ) Max. 32 stations per potential segment 2) Only bus structure (line) allowed 3) Max. length of a bus line 200 m 4) Length of branch line max. 5 m without terminating resistor 5) us line termination only permissible at the beginning and end of a bus line Since this specification only defines the rough reference data, the data under points 3 and 4 detailing the transmission rate and the type of cable used is specified by the manufacturer of the particular bus system. This information can be found in the system manufacturer s manual. Example applications for repeaters Electrical isolation/ bus segmentation (fig. 3) - allows the permitted length of the bus line to be doubled/multiplied. - increases the availabilty in the case of bus line short-circuits, since the short-circuit only affects the particular power segment. - allows the number of stations to be increased to n x 32, since the full RS-485 specification is valid in each power segment. - allows higher transmission rates with division into smaller segment lengths. Hybrid/network structures (fig. 4, page 9) are made possible for the first time by the use of repeaters. freely selectable installation concept, independent of the restrictive line structure is thus possible. ctive branch lines allow the full RS-485 specification to be exploited per segment in star and tree structures, too. System-specific example of an application for PROFIUS (fig. 4, page 3) The correlation between permitted conductor length (without repeater) and transmission rate, as specified in the PROFIUS standard EN 5070-2-2, is shown in the following table. This data is band on the use of type standard PROFIUS cable. max. 5 m max. 32 stations PSM ME / P max. 32 stations PSM ME / P max. 32 stations Fig. 2 PSM ME / P Fig. 3 PHOENIX CONTCT page 2 of 9

D() D() 6 D() D() D() D() 66 D() D() D() D() D() D() 6 6 D() D() 0V 0V 0V 0V 6 D() D() 6 D() D() 6 D() D() D() D() D() D() 6 PSM-ME-/-P pplication notes for Profibus systems EN 5070 (Profibus standard) specifies different lengths for bus lines, depending on the transmission rate. To bridge greater distances, several segments, separated by repeaters, can be wired in series. This so-called cascading depends on the transmission rate. Maximum cascading and the different segment lengths are listed in the following table. The maximum bus coverage results from the correlation: (max. cascading + ) x segment length = max. bus coverage Transmission rate 9. 9 5 in kbit/s 6 9.2 3.75 87.5 00 500 Segment length in m 4 2 200 200 200 000 00 00 Maximum cascading 9 9 9 6 5 5 Maximum bus coverage in km 40 m 2 2 2 7 2.4,2 PSM ME / P 25 m PSM ME / P PSM ME / P Ord.-No.: Ord.-No.: 2744429 2744429 PSM ME / P Ord.-No.: 2744429 = us terminating resistor 0 m 30 m 40 m 20 m 20 m 75 m 20 m PSM ME / P 0 m 0 m 50 m 00 m 00 m Fig. 4 PHOENIX CONTCT page 3 of 9

PSM-ME-/-P 3. Order data Repeater, for electrical isolation and increasing the range in RS-485 2-wire bus systems, 3-way isolation, rail-mountable Type Order No. Pcs. Pkt. PSM-ME-/-P 27 44 42 9 3.. ccessories Compact power supply, primary switchedmode, 24 V DC, 650 m, rail-mountable 230 V C 20 V C MCR-PS 230 C/24 DC/650 28 95 4 MCR-PS 20 C/24 DC/650 28 96 7 SU-D plug, 9-pos., with screw connection and one cable entry SU-D plug 9-pos., with screw connection for PROFIUS up to 2 Mbit/s Terminating resistor and outgoing bus line can be enabled and disabled via a slide switch 3.2. Technical Data Supply voltage Frequency Rated current consumption Connection LED operational availability RS 485 interfaces + Data format/coding Terminating resistor Data direction switching Data indicator Transmission rate in kbit/s Transmission channels (I/O) Transmission medium Transmission length Number of cascadable repeaters it time distortion in % Connection 4. General data Protection circuit Transient discharge Electrical 3-way isolation Test voltage Resistance to vibration mbient temperature range Protection type Housing: Connection data (conductor cross section) - COMICON plug connectors Weight pproval socket pin socket pin SUCON 9/F-SH 27 6 49 9 SUCON 9/M-SH 27 6 50 9 SUCON-PLUS-PROFI 27 44 34 8 24 V C/DC ± 20 % DC-60 Hz typ. 90 m pluggable COMICON screw terminal block LED green DIN 66 259-4 RS-485 2-wire, half duplex URT (0/ bit NRZ ) ), slip-tolerant 220 Ω, pull up/down 390 Ω, integrated and switchable automatic control LED green, () receive data Port, dynamic LED yellow, () transmit data Port, dynamic can be set via DIP switch [kbit/s]: 4.8 / 9.6 / 9.2 / 38.4 / 57.6 / 75 / 93.75 / 5.2 / 36 / 87.5 / 375 / 500 / 500 2(/),,, half duplex twisted pair, shielded corresponding to the bus system used depending on transmission rate and cable type 9 (4.8-93.75 kbit/s); 8 (5.2 kbit/s); 7 (36 kbit/s); 6 (87.5 kbit/s) 5 (375-500 kbit/s) in general <.5 % 2) pluggable COMICON screw terminal block Material Dimensions (W / H / D) Y-capacitors, suppressor diodes, gas-filled surge arresters via metal foot on EN mounting rail power supply // RS-485 // RS-485 2 kvrms, 50 Hz, min. 5 g in acc. with IEC 68-2-6 0 C to + 55 C IP 20 P-V0 (99 / 22.5 / 4.5) mm 0.2-2.5 mm 2 (WG 24-2) approx. 30 g u ) NRZ: Non Return To Zero 2) Valid for the device: distortions caused by system-specific cable are not taken into account. PHOENIX CONTCT page 4 of 9

4,5 PSM-ME-/-P c Complies with EMC guideline 89/336/EEC EMC (electromagnetic compatibility) Immunity to interference in acc. with EN 50082-2 Electrostatic discharge (ESD) Electromagnetic HF field: mplitude modulation: Pulse modulation: Fast transients (urst) Signal: Supply: EN 6000-4-2 EN 6000-4-3 EN 6000-4-4 Criterion 8 kv discharge in air 6 kv contact discharge Criterion 0 V/m 0 V/m Criterion 2 kv/5 khz 4kV/5 khz Surge voltage capacities (Surge) Signal: Supply: Conducted disturbance Noise emission in acc. with EN 5008-2 EN 6000 corresponds to IEC 000 EN 550 corresponds to CISPR EN 6000-4-5 EN 6000-4-6 EN 550 Criterion : Normal operating behavior within the defined limits. Criterion : Temporary impairment of operational behavior that the device corrects itself. Class : rea of application: industry, without special installation measures. Criterion 2 kv/2 Ω 0.5 kv/2 Ω Criterion 0 V Class 99 22,5 Fig. 5 PHOENIX CONTCT page 5 of 9

RS - 485 Port RS - 485 Port PSM-ME-/-P Function elements Supply voltage 24 V C/DC 2 RS-485 interface connection (Port ) 3 LED supply voltage () 4 LED receive data at Port () 5 LED transmit data at Port () 6 RS-485 interface connection (Port ) 7 Shield connector 8 Snap-on foot for mounting rails in acc. with DIN EN 50 022 5. Operational Diagram OV OV D() D() 390Ω 220Ω 390Ω +5V () D() D() D() D() 6 D() D() R() R() 6 PSM-ME-RS232/-P Ord.-Nr.: 27 44 429 6 7 8 Steckbare Schraubklemme Screw terminal block loc de jonction a`vis orne de tornillo gn ye +5V () +5V () gn RS232 390Ω 220Ω 390Ω PSM ME / P 500 OFF OFF OFF OFF () 87,5 OFF OFF ON ON 5,2 OFF ON PSM-ME-/-P rt.-nr.: 27 44 42 9 57,6 OFF OFF 9,2 38,4 OFF ON 4,8 ON OFF 9,6 ON ON () PPROTIONEN / PPROVLS +5V () 93,75 OFF ON 5 6 D() D() SPEED DIP-Switch (kbit/s) 2 3 4 D() D() 4 3 2 Fig. 6 Shield D() D() us - Management DT RTE Shield Shield Fig. 7 PHOENIX CONTCT page 6 of 9

PSM-ME-/-P 6. Notes on connection 6.. Connections (fig. 8) Plug connector power supply Connect 24 V C/DC ± 20 % via the COMICON plug connector (PIN and 3). Operational availability is signaled via the LED 3. 2 RS-485 interface (Port ) pluggable screw terminal block 4 RS-485 interface (Port ) pluggable screw terminal block 5 Shielded connection terminal block 6.2. Mounting in the switch cabinet (fig. 9) Mounting (on 35 mm mounting rails in acc. with DIN EN 50 022): Hinge the device into the upper edge of the mounting Note: The mounting rail must be connected to ground potential. This is the only way to guarantee that the integrated surge voltage protection functions and that the shield of the bus conductor makes contact effectively. rail and snap it in with a downward motion. Dismantling: Pull back the metal disassembling lever with the aid of a screwdriver and remove the device from the top. D() D() D() D() 6 D() D() R() R() 6 PSM-ME-RS232/-P 4 5 6 PSM ME / P RS232 Ord.-Nr.: 27 44 429 0V D() PSM ME / P 0V D() PSM-ME-/-P rt.-nr.: 27 44 42 9 SPEED DIP-Switch (kbit/s) 2 3 4 () 4,8 ON OFF 9,6 ON ON 9,2 38,4 OFF ON 57,6 OFF OFF 93,75 OFF ON 5,2 OFF ON 87,5 OFF OFF ON ON () 500 OFF OFF OFF OFF PPROTIONEN / PPROVLS 6 D() D() 2 3 24 V 0 V Fig. 8 Fig. 9 PHOENIX CONTCT page 7 of 9

PSM-ME-/-P 6.3. Shielding the data cables Use shielded twisted pair cables. Connect the cable shield to both sides of the transmission path! D() D() R() R() 6 RS232 Shielding of the data cables is carried out via a shielding terminal block that is fixed in the 6 terminal block (fig. 0). The 6 terminal block is connected capacitively (Port ) or firmly (Port ) to the mounting rail contact on the underside of the device. The shield connector is included in the scope of supply. 7. The RS-485 interface 7. Connections Designation Data line (neg.) D() Data line (pos.) D() Functional ground Ground 6 7.2. Configuration For configuration, release the top of the housing on both sides. Pull the p.c.b. out of the housing as far as possible 2 (fig. ). Static charges can damage electronic devices. Discharge the electrical charge from your body before opening and configuring the device. To do so, touch a grounded surface, e.g. the metal housing of the switch cabinet. Transmission rate (DIP -4) D() D() D() D() 6 D() D() R() R() 6 The transmission rate is set via the DIP switches S-S4 (fig. 3) and using the table below (fig.2). ll PSM repeaters and stations must be adjusted to the same transmission rate! D() D() D() D() 6 2 PSM-ME-RS232/-P RS232 Ord.-Nr.: 27 44 429 () OTIONEN / PSM ME / P SPEED DIP (kbit/s) 2 3 4 4.8 ON OFF 9.6 ON ON 9.2 38.4 OFF ON 57.6 OFF OFF 93.75 OFF ON 5.2 OFF ON 87.5 OFF OFF ON ON PSM-M rt.-nr. 57,6 OFF OFF 93,75 OFF ON 5,2 OFF ON 87,5 OFF OFF ON ON 500 OFF OFF OFF OFF Fig. 0 PSM-ME rt.-nr.: 38,4 OFF ON 57,6 OFF OFF 93,75 OFF ON 5,2 OFF ON 87,5 OFF OFF ON ON () 500 OFF OFF OFF OFF Fig. PPROTIONEN / P 500 OFF OFF OFF OFF Fig. 2 PHOENIX CONTCT page 8 of 9

6 D() D() 6 D() D() 6 D() D() D() D() 6 D() 0V D() 0V 6 D() D() D() D() 6 D() 0V D() 0V 6 D() D() PSM-ME-/-P 7.3. Terminating resistors for the RS-485 connections To terminate the RS-485 bus line, there is a connectable terminating resistor integrated in the device for each port. The terminating resistor is activated by moving the slide-type switch to ON (fig. 3). The bus line must be terminated at the two most distant bus ends. n exemplary hybrid installation is shown in fig.4, comprising line, star and tree topologies. The terminating resistors shown here make it clear that the two most distant bus ends of a power segment must always be terminated. It also becomes clear that a repeater opens a separate segment that must in turn be terminated at the most distant bus ends. In this example, the repeaters are used to increase the range or to add branch lines. To bridge greater distances, several segments, separated by repeaters, are wired in series. The resulting maximum bus coverage can be seen in the following table. Transmission rate in kbit/s Segment length in m Maximum no. of cascadable repeaters Maximum bus coverage in km 4.8 9.6 9.2 38.4 57.6 75.0 93.75 5.2 36.0 87.5 375 500 500 200 200 200 200 200 200 200 000 000 000 600 400 200 9 9 9 9 9 9 9 8 7 6 5 5 5 2 2 2 2 2 2 2 9 8 7 3.6 2.4.2 200 m PSM ME / P Ord.-No.: 2744429 30 m 5 m PSM ME / P PSM ME / P Ord.-No.: 2744429 5 m PSM ME / P PSM ME / P Ord.-No.: Ord.-No.: 2744429 2744429 (Port ) (Port ) SPEED 60 m PSM ME / P ON 2 3 4 2 m 2 m 200 m 2 m 60 m = us terminating resistor = Main segment = ranch segment PHOENIX CONTCT page 9 of 9 2 3 4 () PSM-ME-/-P rt.-nr.: 27 44 42 9 4,8 ON OFF 9,6 ON ON 9,2 38,4 OFF ON 57,6 OFF OFF 93,75 OFF ON 5,2 OFF ON 87,5 OFF OFF ON ON 500 OFF OFF OFF OFF () PPROTIONEN / PPROVLS SPEED DIP-Switch (kbit/s) 2 3 4 Fig. 3 Fig. 4 PHOENIX CONTCT 0.08.00 TNR: 504406-02 http://www.phoenixcontact.com