Measuring Instruments. Measuring Instruments

Similar documents
Power-meters three-phase

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

3-phase meter with direct connection and pulse or Modbus RS485 output

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

EM-72 Electricity Meters for Current Transformers

Energy Management Energy Analyzer Type EM210 MID

Energy Management Three-phase energy meter with output modules Type EM4-DIN

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

Data Sheet. RISH Master Record %THD

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Technical Data Sheet. x1000. kwh R Y B

Single phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Meter Type EM340

Energy Management Energy Analyzer Type EM112

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Centrale de mesure Power Meter PM500 Merlin Gerin

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Energy Management Energy Meter GM3T E GM3T-RS485 E

Digital Multifunction Instrument - Rish Master 3440

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

Energy Management Energy Analyzer Type EM111

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Energy Management Energy Meter Type EM21 72R Retro-Fit

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

N30P DIGITAL PANEL METER

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Analyzer Type EM210

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Technical Data Sheet AMIK 300 / 301

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Power Meter Series PM3200 Functions and characteristics

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Introduction DIN rail mounted electricity meters

MBus Interface for Energy and Power meters AEM and APM

Energy Management Energy Analyzer Type EM270-72D

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

AMIK 200 / 201 Technical Data Sheet

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

3 phase energy meters with integrated Serial Modbus interface

Contents. Introduction and description Package contents Device identification PM Options... 80

Energy Management Energy Analyzer Type EM280-72D

Single phase energy meter with Serial Modbus interface

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

GSC57 Rel of 257/10/05

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Universal-Transducer Multi-E11-MU

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

MultiCube Multi-Function Electricity Meter. Installation and Operation

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

Energy Management Modular Smart Power Transducer Type SPT-90

Integra 1560 and 1580 Digital Transducer Systems

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

PEM353. Universal measuring device

Energy Management Energy Meter Type EM110

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Technical features table for miniature circuit-breakers SH 200 Series

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Energy Management Modular Power Analyzers Type WM2-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96

UPM209 1/5A CT, 80A Multifunction three-phase meter

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Transformers, Power Supply Units and Socket Outlets

Measurement and control. Digital instruments and measuring transducers

DM-III Multitest & DM-III Multitest F Power Quality Recorders

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

METRAClip87 and 88 Clamp Multimeters

Universal measuring transducer

Side view View from below Rear view

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

Measuring Instruments wa_sg05811 wa_sg04911 100

Measuring Instruments PHASE OUT TYPE Power Meter KWZ System Rated Current Type Designation Article No. Units per package SG10007 1N 40 A KWZ-230 286839 1 / 60 3N 3N 5 A,CT 63 A KWZ-3PH 110825 1 / 30 KWZ-3PH-63 110826 1 / 30 KWZ-3PH-63 Power Meter EME System Rated Current Type Designation Article No. Units per package wa_sg05311 1N 1N 1N 1N 1N 1N 1N 1N 32 A 32 A, MID cert. 40 A 40 A, MID cert. 80 A 80 A, MID cert. 125 A 125 A, MID cert. EME1P32 167397 1 EME1P32MID 167398 1 EME1P40 167399 1 EME1P40MID 167400 1 EME1P80 167401 1 EME1P80MID 167402 1 EME1P125 167403 1 EME1P125MID 167404 1 EME1P125 3N 3N 3N 3N 3N 3N 80 A 80 A, MID cert. 5 A, CT 5 A, CT MID cert. 125 A 125 A, MID cert. EME3P80 167413 1 EME3P80MID 167414 1 EME3PCT 167417 1 EME3PCTMID 167418 1 EME3P125 167415 1 EME3P125MID 167416 1 Accessories Current Transformer Z-MG/WAK: maximum cable diameter 21 mm Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm, maximum cable diameter 23 mm / 30 mm - according to type, see dimension diagramms Communication modules wa_sg00312 Designation Type Designation Article No. Units per package Communication module Communication module MBUS Communication module with MODBUS EMECLAN 167419 1 EMECMBUS 167420 1 EMECMODB 167421 1 EMECMODB Basic Devices wa_sg05711 System Rated Current Type Designation Article No. Units per package 3N 3N 3N 3N 3N 3N 3N 3N 5 A, CT S0 5 A, CT S0 MID cert. 63 A, S0 63 A, S0 MID cert. 63 A, MODBUS 63 A, S0 MODBUS MID cert. 80 A, S0 MID cert. 80 A, S0 MODBUS MID cert. EME3PCTB 167405 1 EME3PCTBMID 167406 1 EME3P63B 167407 1 EME3P63BMID 167408 1 EME3P63BMODBUS 167409 1 EME3P63BMODBUSMID 167410 1 EME3P80BMID 167411 1 EME3P80BMODBUSMID 167412 1 101

Multimeter EME3PMMCT5 Communication link Type Designation Article No. Units per package S0 EME3PMMCT5 171631 1 LAN Server Modbus/TCP EMELSMODBUS Description Type Designation Article No. Units per package Data Concentrator with Modbus/TCP EMELSMODBUS 170509 1 SG2802 PHASE OUT TYPE Function/Measuring Range Type Designation Article No. Units per package Analogue Ammeter and Voltmeter Z-MG Ammeter/0-10 A Z-MG/AA-10 248228 1 / 30 Ammeter/0-40 A Z-MG/AA-40 248229 1 / 30 Ammeter transformer/0-600a, x/5a Z-MG/AA5-WS 248227 1 / 30 Voltmeter/0-250 V Z-MG/VA-250 248223 1 / 30 Voltmeter/0-500 V Z-MG/VA-500 248224 1 / 30 SG30012 PHASE OUT TYPE Digital Ammeter and Voltmeter Z-MG Ammeter/0-20 A Z-MG/AD-20 248225 1 / 30 Ammeter transformer/0-999a, x/5a Z-MG/AD-999 248226 1 / 30 Voltmeter/0-600 V Z-MG/VD-600 248222 1 / 30 Ammeter+Voltmeter/0-8kA, x/5a; Z-MG/VD+AD 263140 1 / 30 0-600V Ammeter+Voltmeter/0-8kA, x/5a; 0-600V, 2 programmable contacors Z-MG/VD+AD+S 263141 1 / 30 Accessories Current transformer Z-MG/WAS.., Z-MG/WAK.. Exchangeable scale Z7-MG/WS-.. for Z-MG/AA5-WS 102

Digital Ammeter and Voltmeter EM Description Type Designation Article No. Units per package wa_sg00212 Ammeter Voltmeter EMA20 167423 1 EMV600 167422 1 Accessories Current Transformer Z-MG/WAK: maximum cable diameter 21 mm Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm, maximum cable diameter 23 mm / 30 mm - according to type, see dimension diagramms SG8797 SG8897 PHASE OUT TYPE Function/Ratio/Measuring Range Type Designation Article No. Units per package Current transf. f. cable / 40/5 Current transf. f. cable / 50/5 Current transf. f. cable / 60/5 Current transf. f. cable / 80/5 Current transf. f. busbar / 100/5 Current transf. f. busbar / 150/5 Current transf. f. busbar / 200/5 Current transf. f. busbar / 250/5 Current transf. f. busbar / 300/5 Current transf. f. busbar / 400/5 Current transf. f. busbar / 500/5 Current transf. f. busbar / 600/5 Current transf. f. busbar / 800/5 Current transf. f. busbar / 1000/5 Scale to Z-MG/AA5-WS / 0-50 Scale to Z-MG/AA5-WS / 0-60 Scale to Z-MG/AA5-WS / 0-80 Scale to Z-MG/AA5-WS / 0-100 Scale to Z-MG/AA5-WS / 0-150 Scale to Z-MG/AA5-WS / 0-200 Scale to Z-MG/AA5-WS / 0-250 Scale to Z-MG/AA5-WS / 0-300 Scale to Z-MG/AA5-WS / 0-400 Scale to Z-MG/AA5-WS / 0-500 Scale to Z-MG/AA5-WS / 0-600 Z-MG/WAK-40 101619 1 Z-MG/WAK-50 101620 1 Z-MG/WAK-60 101621 1 Z-MG/WAK-80 101622 1 Z-MG/WAS-100 101623 1 Z-MG/WAS-150 101625 1 Z-MG/WAS-200 101626 1 Z-MG/WAS-250 101627 1 Z-MG/WAS-300 101628 1 Z-MG/WAS-400 101629 1 Z-MG/WAS-500 101630 1 Z-MG/WAS-600 101631 1 Z-MG/WAS-800 101632 1 Z-MG/WAS-1000 101624 1 Z7-MG/WS-50 850001066 1 Z7-MG/WS-60 850001086 1 Z7-MG/WS-80 850001087 1 Z7-MG/WS-100 850001067 1 Z7-MG/WS-150 850001068 1 Z7-MG/WS-200 850001069 1 Z7-MG/WS-250 850001070 1 Z7-MG/WS-300 850001088 1 Z7-MG/WS-400 850001089 1 Z7-MG/WS-500 850001092 1 Z7-MG/WS-600 850001093 1 PHASE OUT TYPE Operating Hours Counter BSZ Readout Rated Voltage Type Designation Article No. Units per package SG15805 5+2digit 5+2digit 230V 50Hz 24V 50Hz BSZ/230 276309 1 / 60 BSZ/24 276308 1 / 60 103

Operating Hours Counter ASOHC230 wa_sg04411 Readout Rated Voltage Type Designation Article No. Units per package 5+2stellig 230V 50Hz ASOHC230 167424 1 PHASE OUT TYPE Pulse Counter Z-IMZ Readout Rated Voltage Type Designation Article No. Units per package SG2702 7digit 7digit 230V 50Hz 24V 50Hz Z-IMZ/230 248206 1 / 60 Z-IMZ/24 248207 1 / 60 Pulse Counter ASPC230 wa_sg05011 Readout Rated Voltage Type Designation Article No. Units per package 7digit 230V 50Hz ASPC230 167425 1 104

Power Meter KWZ Power meter according to IEC/EN 61036 for sub-measurement For active energy 3-phase AC types also suitable for uneven load Type KWZ-230: single-phase kwh-meter Type Z-KWZ-3PH: for 4-wire 3-phase AC system with external transducer X/5A; Type Z-MG/WA. Transducer ratios according to table Type Z-KWZ-3PH-25: For 4-wire 3-phase AC system with direct connection Connection diagram KWZ-230 L N 1 4 Output 3 6 7 8 Load KWZ-230 Electrical Rated voltage U n 230 V AC Working range 0.9-1.2 x U n Rated current I b 10A, direct Maximum currenti max 40 A Rated frequency 50/60Hz Overload short time Back-up fuse MCB: C40 40 A gg/gl Sealable no Auxiliary voltage from measurement Power consumption Power loss 2 W Input signal sinusoidal Power factor cosϕ=0.5 inductive to cosϕ=0,8 capacitive Accuracy class 1 Resolution 0.1 kwh LED signal 640 pulse/kwh Own consumption per phase <8 VA DIP adjustment switch for transducer ratios Pulse output rated values 5-48V DC, 50mA Pulse value (jumper) 10 pulse/kwh Switching contact (potential-free) 1 NO Rated peak withstand voltage(1.2/50) µs 5 kv Test voltage 50Hz/1min. 2.5 kv Mechanical Frame size 45 mm Device height 90 mm Device width 35 mm (2MU) Weight 180 g Calibrateable no Display 5+1digit Maximum display reading 99999,9kWh Height of figures 4 mm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection, built-in IP51 Upper and lower terminals lift terminals Terminal capacity 12mm 2 (2.5mm 2 pulse-outp.) Tightening torque of terminal screws 2 Nm Permitted relative humidity 90% Perm. ambient temperature range -5 to +55 C Flame class acc. to UL 94 V0 Dimensions (mm) KWZ-230 176

Power Meter KWZ-3PH Power meter according to EN 62053 for sub-measurement For active/reactive energy For unbalanced load Programming by front keyboard, 2 keys Sealability front frame and terminal Connection diagram KWZ-3PH KWZ-3PH-63 KWZ-3PH KWZ-3PH-63 Electrical Rated voltage U n 230-240/400-415 V AC 230-240/400-415 V AC Working range 110-254/190-440 V AC 110-254/190-440 V AC Rated current I b 1 and 5 A 10 A Maximum current I max 6 A 63 A Maximum back-up fuse MCB: B10 or 10A gg/gl MCB: C63 or 63A gg/gl (only voltage pathes) Rated frequency 50 and 60 Hz 50 and 60 Hz Frequency range 47-63 Hz 47-63 Hz Power consumption per phase (current path) 0.5 VA (each phase) 4 VA (each phase) Overcurrent short time 20 x I max / 0.5 s 30 x I max / 10 ms Auxiliary voltage from measurement from measurement Input signal sinusoidal sinusoidal Accuracy class 1 1 Metering LED 1 pulse / 0.1 Wh 1 pulse / Wh Pulse output rated values max. 110V AC/DC, 50mA max. 110V AC/DC, 50mA Switching contact (potential-free) Opto coupler Opto coupler S0-Interface according S0-Interface according DIN 43864 / EN 62053-31 DIN 43864 / EN 62053-31 Pulse frequency (selectable) 1 pulse / 10Wh-100Wh-1kWh-10kWh 1 pulse / 1Wh-10Wh--100Wh1kWh-10kWh optional 1 pulse / 10VArh-100VArh- optional 1 pulse / 10VArh-100VArh- 1kVArh-10kVArh 1kVArh-10kVArh Pulse duration (selectable) 50-100-150-200-300-400-500 ms 50-100-150-200-300-400-500 ms Programmable parameters connection (1-phase, 3-phases connection (3-phases 3- or 4-wire), 3- or 4-wire), external VT and counting, power demand, pulse CT-ratio, power demand, output pulse output Overvoltage category III III Insulation voltage rating (phase - phase) 450 V 300 V Rated impulse withstand voltage (1.2/50) µs 5 kv 5 kv Test voltage Input/pulse-output 2.75 kv 2.75 kv all circuits and earth 4 kv 4 kv Protection class II II Mechanical Frame size 45 mm 45 mm Device height 89 mm 89 mm Device width 71.2 mm 71.2 mm Weight 260 g 260 g Display LCD 8 digit LCD 8 digit Digit height 6 mm 6 mm Maximum display setable 999999,99 kwh Resolution setable 10 W Measurement display subdivided on 6 pages subdivided on 7 pages Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection, front frame / terminals IP52 / IP20 IP52 / IP20 Upper and lower terminals screw terminals screw terminals Terminal capacity Current terminal rigid cable 0.05-4mm 2 input: rigid cable 1-10mm 2 flexible cable 0.05-2.5mm 2 flexible cable 1-13mm 2 Voltage terminal rigid cable 0.05-4mm 2 output: rigid cable 1-4mm 2 flexible cable 0.05-2.5mm 2 flexible cable 1-3mm 2 Permitted relative air humidity suitable for tropical dissipation suitable for tropical dissipation Reference temperature 23 C ±2 C 23 C ±2 C Perm. ambient temperature range -5 to +55 C -5 to +55 C Storage and transportation temperature range -25 to +70 C -25 to +70 C Pollution degree 2 2 177

Dimensions (mm) Wiring diagrams KWZ-3PH 1-phase 3-phases 3-wires balanced 3-phases 3-wires unbalanced 3-phases 3-wires unbalanced 3-phases 3-wires unbalanced 3-phases 3-wires unbalanced 3-phases 4-wires balanced 3-phases 4-wires unbalanced Wiring diagrams KWZ-3PH-63 3-phases 3-wires 3-phases 4-wires 178

Energy-meters single-phase 32-40 A, EME Digital active energy meter with measurement I - U - Hz - PF measurement of active instantaneous power, by IR side set up communication - 1 tariff - 1 S0 Active energy-meters for single-phase alternating current with a, 7 digits counter. These meters have 1 S0 output generating pulses for remote processing of the active energy measurements for 1 tariff. Display LCD For direct connection 32 A and 40 A 7 digits for energy values indication Accuracy class 1 for active energy according to EN 50470-3 (B) Most attractive operating range current (I st... I max ) - for direct connection 32 A and 40 A = 0.020... 32 A or 40 A The standard versions are designed to be combined with the communication module Active energy register zero setting (not for MID types) Active energy register in T1 import/export Instantaneous power active import/export display Current RMS Voltage RMS Power factor Frequency FW release FW checksum 1 DIN modules wide (18 mm) EME1P32 EME1P32MID EME1P40 EME1P40MID direct connection 32 A direct connection 40 A Data in compliance with EN 50470-1, EN 50470-3 and EN 62053-31 General characteristics Housing DIN 43880 DIN 1 modules 1 modules Mounting EN 60715 35 mm DIN rail DIN rail Depth mm 70 70 Reference standard active energy - EN 50470-1-3, EN 62053-31 EN 50470-1-3, EN 62053-31 Operating features Connectivity to single-phase network n wires 2 2 Storage of energy values and configuration FRAM memory - yes yes Supply Rated control supply voltage U n VAC 230 230 Operating range voltage V 184... 276 184... 276 Rated frequency f n Hz 50 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) 8 (0.6) Overload capability Voltage U n continuous V 276 276 momentary (1 s) V 300 300 Current I max continuous A 32 40 momentary (10 ms) A 960 1200 Display (readouts) Display type LCD n digits 7 (2 decimals) 7 (2 decimals) digit dimensions mm x mm 6.00 x 3 6.00 x 3 Active energy: 1 display, 7-digit kwh 0.00... 999999.9 0.00... 999999.9 Instantaneous tariff measurement - 1 1 1 display, 1-digit - T1 T1 Display period refresh s 1 1 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and poweracc.to EN 50470-3 % ±1 (B) ±1 (B) Measuring input Type of connection phase/n - direct direct Operating range voltage phase/n V 184... 276 184... 276 Current I ref A 5 5 Current I min A 0.25 0.25 Operating range current (I st... I max ) direct connection A 0.02... 32 0.02... 40 Frequency Hz 50 50 Input waveform - alternating alternating Starting current for energy measurement (I st ) ma 20 20 Pulse output S0 acc.to EN 62053-31 Pulse output for active energy - yes yes Pulse quantity Imp/kWh 1000 1000 Pulse duration ms 90 90 Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 5000 5000 179

EME1P32 EME1P32MID EME1P40 EME1P40MID direct connection 32 A direct connection 40 A Safety acc. to EN 50470-1 Indoor meter - yes yes Degree of pollution - 2 2 Operational voltage V 300 300 AC voltage test (EN 50470-3, 7.2) kv 4 4 Impulse voltage test 1.2/50 µs-kv 6 6 Protection class (EN 50470) class II II Housing material flame resistance UL 94 class V0 V0 Safety-sealing between upper and lower housing part - no yes no yes Adaptor for Communication Plug-and-play technology - LAN Interface (TCP/IP) Ethernet 802.3 EMECLAN 10/100 Mbps 10/100 Mbps Modbus RTU, Ascii RS-485 3 wires EMECMODB up to 19.200 bps up to 19.200 bps M-Bus RS-485 2 wires EMECMBUS up to 9.600 bps up to 9.600 bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ1 PZ1 Type cage pulse output blade for slotted screw mm PZ0 PZ0 Terminal capacity main current paths solid wire min. (max.) mm 2 16 16 stranded wire with sleeve min. (max.) mm 2 16 16 Terminal capacity pulse outlet solid wire min. (max.) mm 2 0.15 (2.5) 0.15 (2.5) stranded wire with sleeve min. (max.) mm 2 0.15 (4) 0.15 (4) Environmental conditions Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C -10... +55-10... +55 Limit temperature of transportation and storage C -25... +70-25... +70 Relative humidity (not condensation) % 80 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Dimensions (mm) Connection diagram A Miniature Circuit Breaker of 32A or 40A is recommended. 180

Energy-meters single-phase 80 A, EME Digital active and reactive energy meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 Active and reaktive (not for MID types) energy-meters for single-phase alternating current with either 1, 7 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 80 A 7 digits for energy values indication Accuracy class 1 for active energy and power according to EN 50470-3 (B) Accuracy class 2 for reactive energy and power according to EN 62053-23 Most attractive operating range current (I st... I max ) for direct connection 80 A = 0.02... 80 A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display (MID types: only active power) Sealable terminal covers 2 DIN modules wide (36 mm) EME1P80 EME1P80MID direct connection 80 A Data in compliance with EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31 General characteristics Housing DIN 43880 DIN 2 modules Mounting EN 60715 35 mm DIN rail Depth mm 70 Reference standard active energy - EN 50470-1-3, EN 62053-23-31 reactive energy - pulse output Operating features Connectivity to single-phase network n wires 2 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V 184... 276 Rated frequency f n Hz 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous V 276 momentary (1 s) V 300 Current I max continuous A 80 momentary (10 ms) A 2400 Display (readouts) Display type LCD n digits 7 (1 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 7-digit tariffs 1-2 kwh 000000.0... 999999.9 + display import or export (arrow) overflow kwh 999999.9... 000000.0 Reactive energy: 1 display, 7-digit tariffs 1-2 kvarh 000000.0... 999999.9 + display import or export (arrow) overflow kvarh 999999.9... 000000.0 Instantaneous active power: 1 display, 3-digit W, kw or MW 000... 999 Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar 000... 999 Instantaneous tariff measurement - 1 1 display, 1-digit - T1 or T2 Display period refresh s 1 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and poweracc.to EN 50470-3 % B Reactive energy and power acc.to EN 62053-23 % 2 Measuring input Type of connection phase/n - direct Operating range voltage phase/n V 184... 276 Current I ref A 15 Current I min A 0.75 Operating range current (I st... I max ) direct connection A 0.025... 80 Frequency Hz 50 Input waveform - sinusoidal Starting current for energy measurement (I st ) ma 25 181

EME1P80 EME1P80MID direct connection 80 A Pulse output S0 acc.to EN 62053-31 Pulse output for active and reactive energy T1 and T2 yes Pulse quantity Imp/kWh 1000 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 Safety acc. to EN 50470-1 Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN 50470-3, 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Adaptor for Communication Plug-and-play technology - LAN Interface (TCP/IP) Ethernet 802.3 EMECLAN 10/100 Mbps Modbus RTU, Ascii RS-485 3 wires EMECMODB up to 19.200 bps M-Bus RS-485 2 wires EMECMBUS up to 9.600 bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1.5 (35) stranded wire with sleeve min. (max.) mm 2 1.5 (35) Terminal capacity pulse outlet solid wire min. (max.) mm 2 0.14 (2.5) stranded wire with sleeve min. (max.) mm 2 0.14 (1.5) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C -10... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Dimensions (mm) Connection diagram A Miniature Circuit Breaker of 80A is recommended. 182

Energy-meters single-phase 125 A, EME Digital active and reactive energy meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs Active energy-meters for single-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 125 A 8 digits for energy values indication Accuracy class 1 for active energy and power according to EN 50470-3 (B) Accuracy class 2 for reactive energy and power according to EN 62053-23 Most attractive operating range current (I st... I max ) for direct connection 125 A = 0.020... 125 A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display Sealable terminal covers 3 DIN modules wide (52 mm) EME1P125 EME1P125MID direct connection 125 A Data in compliance with EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31 General characteristics Housing DIN 43880 DIN 3 modules Mounting EN 60715 35 mm DIN rail Depth mm 70 Reference standard active energy - EN 50470-1-3, EN 62053-23-31 reactive energy - pulse output Operating features Connectivity to single-phase network n wires 2 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V 184... 276 Rated frequency f n Hz 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous V 276 momentary (1 s) V 300 Current I max continuous A 125 momentary (10 ms) A 3750 Display (readouts) Display type LCD n digits 8 (2 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 8 digit tariffs 2 Wh 0.01 + display import or export (arrow) overflow MWh 999999.99 Reactive energy: 1 display, 8 digit tariffs 2 varh 0.01 + display import or export (arrow) overflow Mvarh 999999.99 Instantaneous active power: 1 display, 3-digit W, kw or MW 000... 999 Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar 000... 999 Instantaneous tariff measurement - 1 1 display, 1-digit - T1 or T2 Display period refresh s 1 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and poweracc.to EN 50470-3 % B Reactive energy and power acc.to EN 62053-23 % 2 Measuring input Type of connection phase/n - direct Operating range voltage phase/n V 184... 276 Current I ref A 5 Current I min A 0.25 Operating range current (I st... I max ) direct connection A 0.020... 125 Frequency Hz 50 Input waveform - sinusoidal Starting current for energy measurement (I st ) ma 20 183

EME1P125 EME1P125MID direct connection 125 A Pulse output S0 acc.to EN 62053-31 Pulse output for active and reactive energy T1 and T2 yes Pulse quantity Imp/kWh 1000 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 Safety acc. to EN 50470-1 Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN 50470-3, 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Adaptor for Communication Plug-and-play technology - LAN Interface (TCP/IP) Ethernet 802.3 EMECLAN 10/100 Mbps Modbus RTU, Ascii RS-485 3 wires EMECMODB up to 19.200 bps M-Bus RS-485 2 wires EMECMBUS up to 9.600 bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1.5 (50) stranded wire with sleeve min. (max.) mm 2 1.5 (50) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C -10... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Dimensions (mm) Connection diagram A Miniature Circuit Breaker of 125A is recommended. 184

Energy-meters three-phase, transformer 5 A, direct 80 A, EME Digital active and reactive energy-meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 (MID types: displays only active power). Active energy-meters for three-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 80 A, or for transformer.../5 A For transformer primary current of 5 A to 10.000/5 A. Input is in 5 A increments 8 digits - 8 display for energy values indication Detection of connection errors (phase transposition) Accuracy class 1 for active energy and power according to EN 50470-3 (B) Accuracy class 2 for reactive energy and power according to EN 62053-23 Most attractive operating range current (I st... I max ), for direct connection 80 A = 0.015... 80 A, for connection by CT.../5 A = 0.003... 5 A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display (MID types: only active power) Sealable terminal covers 4 DIN modules wide (72 mm) EME3P80 EME3P80MID EME3PCT EME3PCTMID direct connection 80 A CT connection till 10.000/5 A Data in compliance with EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31 General characteristics Housing DIN 43880 DIN 4 modules 4 modules Mounting EN 60715 35 mm DIN rail DIN rail Depth mm 70 70 Reference standard active energy - EN 50470-1-3 EN 50470-1-3 pulse output EN 62053-31 EN 62053-31 Operating features Connectivity to single/three-phase network n wires 2-4 4 Storage of energy values and configuration digital display (EEPROM) - yes yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 T1 and T2 Supply Rated control supply voltage U n VAC 230 230 Operating range voltage V 184... 276 184... 276 Rated frequency f n Hz 50 50 Rated power dissipation (max. for phase) P v VA (W) 8 (0.6) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V 480 480 1 second: phase/phase V 800 800 continuous; phase/n V 276 276 1 second: phase/n V 460 460 Current I max continuous A 80 6 momentary (0,5 s) A - 120 momentary (10 ms) A 2400 - Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err PHASE Err Display type LCD n digits 8 (2 decimal) 8 (2 decimal) digit dimensions mm x mm 6.00 x 3 6.00 x 3 Active energy: 1 display, 8 digit tariffs 2 Wh 0.01 0.01 + display import or export (arrow) overflow MWh 999999.99 999999.99 Reactive energy: 1 display, 8-digit tariffs 2 varh 0.01 0.01 + display import or export (arrow) overflow Mvarh 999999.99 999999.99 Instantaneous active power: 1 display, 3-digit W, kw or MW 000... 999 000... 999 Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar 000... 999 000... 999 Instantaneous tariff measurement 1 display, 1-digit - T1 or T2 T1 or T2 Transformer primary current A - 5... 10.000 Display period refresh s 1 1 Measuring accuracy Active energy and power acc.to EN 50470-3 class 1 B B Reactive energy and power acc.to EN 62053-23 class 2 2 2 185

EME3P80 EME3P80MID EME3PCT EME3PCTMID direct connection 80 A CT connection till 10.000/5 A Measuring input Type of connection direct transformer.../5 A Voltage U n phase/phase V 400 400 phase/n V 230 230 Operating range voltage phase/phase V 319... 480 319... 480 phase/n V 184... 276 184... 276 Current I ref A 5 - Current I n A - 5 Current I min A 0.25 0.05 Operating range current (I st... I max ) direct connection A 0.015... 80 - transformer connection (CT) A - 0.003... 6 Transformer current primary current of the transformer A - 5...10.000 smallest input step adjustment - in 5 A steps A - 5 Frequency Hz 50 50 Input waveform - sinusoidal sinusoidal Starting current for energy measurement (I st ) ma 15 3 Pulse output SO acc.to EN 62053-31 Pulse output for act. and react. energy T1 and T2 yes yes Quantity pulse output for direct connection 80 A Imp/kWh 500 - depending on the transf. factor. Imp/kWh - 100-10-1 Pulse duration ms 30 ±2 30 ±2 Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 90 Permissible current pulse OFF (leakage current max. 230 V AC/DC) µa 1 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 10.000 Safety acc. to EN 50470-1 Indoor meter - yes yes Degree of pollution - 2 2 Operational voltage V 300 300 AC voltage test (EN 50470-3, 7.2) kv 4 4 Impulse voltage test 1.2/50 µs-kv 6 6 Protection class (EN 50470) class II II Housing material flame resistance UL 94 class V0 V0 Safety-sealing between upper and lower housing part - yes no no yes Adaptor for Communication Plug-and-play technology - LAN (TCP/IP) interface Ethernet 802.3 EMECLAN 10/100 Mbps 10/100 Mbps Modbus RTU, Ascii interface RS-485-3 wires EMECMODB up to 19.200 bps up to 19.200 bps M-Bus interface RS-485-2 wires EMECMBUS up to 9.600 bps up to 9.600 bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 PZ1 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1.5 (35) 1 (4) stranded wire with sleeve min. (max.) mm 2 1.5 (35) 1 (4) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) 1 (4) 186

EME3P80 EME3P80MID EME3PCT EME3PCTMID direct connection 80 A CT connection till 10.000/5 A Environmental conditions Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C -10... +55-10... +55 Limit temperature of transportation and storage C -25... +70-25... +70 Relative humidity (not condensation) % 80 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection Direct connection 80 A Dimensions (mm) Connection diagrams A Miniature Circuit Breaker of 80A is recommended. Wire N needs to be connected to the meter. 187

Connection through CT.../5 A till 10.000/5 A Dimensions (mm) Connection diagrams Wire N needs to be connected to the meter. Instructions for the connection of transformer counters A Miniature Circuit Breaker of 6A is recommended. Current transformers must not be operated with open terminals since dangerous high voltages might occur which may result in personal injuries and property damage. In addition to this, the transformers are exposed to thermal overload. 188

Energy-meters three-phase 125 A, EME Digital active and reactive energy-meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 (MID types: displays only active power). Active energy-meters for three-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active and reactive measurements for 2 tariffs. Green backlighted LCD For direct connection 125 A 8 digits - 8 display for energy values indication Detection of connection errors (phase transposition) Accuracy class 1 for active energy and power according to EN 50470-3 (B) Accuracy class 2 for reactive energy and power according to EN 62053-23 Most attractive operating range current (I st... I max ) for direct connection 125 A = 0.020... 125 A The standard versions are designed to be combined with the communication module Energy register zero setting (not for MID types) Energy register for import and export Instantaneous power active and reactive display (MID types: only active power) Sealable terminal covers 6 DIN modules wide (108 mm) EME3P125 EME3P125MID direct connection 125 A Data in compliance with EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31 General characteristics Housing DIN 43880 DIN 6 modules Mounting EN 60715 35 mm DIN rail Depth mm 70 Reference standard active energy - EN 50470-1-3 reactive energy - pulse output EN 62053-23-31 Operating features Connectivity to single/three-phase network n wires 2-4 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active and reactive energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V 184... 276 Rated frequency f n Hz 50 Rated power dissipation (max.) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V 480 1 second: phase/phase V 800 continuous; phase/n V 276 1 second: phase/n V 300 Current I max continuous A 125 momentary (10 ms) A 3750 Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err Display type LCD n digits 8 (2 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 8 digit tariffs 2 Wh 0.01 + display import or export (arrow) overflow MWh 999999.99 Reactive energy: 1 display, 8 digit tariffs 2 varh 0.01 + display import or export (arrow) overflow Mvarh 999999.99 Instantaneous active power: 1 display, 3-digit W, kw or MW 000... 999 Instantaneous reactive power: 1 display, 3-digit var, kvar or Mvar 000... 999 Instantaneous tariff measurement - 1 1 display, 1-digit - T1 or T2 Display period refresh s 1 Measuring accuracy Active energy and poweracc.to EN 50470-3 % B Reactive energy and power acc.to EN 62053-23 % 2 Measuring input Type of connection direct Voltage U n phase/phase V 400 phase/n V 230 Operating range voltage phase/phase V 319... 480 phase/n V 184... 276 189

EME3P125 EME3P125MID direct connection 125 A Measuring input Current I ref A 5 Current I min A 0.25 Operating range current (I st... I max ) direct connection A 0.020... 125 Frequency Hz 50 ±2% Input waveform - sinusoidal Starting current for energy measurement (I st ) ma 20 Pulse output S0 acc.to EN 62053-31 Pulse output for active and reactive energy T1 and T2 yes Quantity pulse output Imp/kWh 500 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 Safety acc. to EN 50470-1 Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN 50470-3, 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Adaptor for Communication Plug-and-play technology - LAN (TCP/IP) interface Ethernet 802.3 EMECLAN 10/100 Mbps Modbus RTU, Ascii interface RS-485-3 wires EMECMODB up to 19.200 bps M-Bus interface RS-485-2 wires ENECMBUS up to 9.600 bps Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1.5 (50) stranded wire with sleeve min. (max.) mm 2 1.5 (50) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C -10... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection 190

Dimensions (mm) Connection diagrams A Miniature Circuit Breaker of 125A is recommended. Wire N needs to be connected to the meter. 191

LAN-TCP/IP interface EMECLAN Additional communication modules for Energy-meter, Network analyzer and Power-meters Additional module for LAN-TCP/IP connection for energy, power, V, I, cosϕ, frequency Data transfer speed LAN limited Mbit/s 100 HW interface RJ 45 connector SW protocol TCP/IP Suitable for both single-phase and three-phase energy meters 1 DIN module wide (18 mm) EMECLAN Data in compliance with IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2 General characteristics Housing DIN 43880 DIN 1 module Mounting EN 60715 35 mm DIN rail Depth mm 70 Power supply Auxiliary voltage rating U n VAC 230 Auxiliary power rating W 1.5 Auxiliary voltage range VAC 0.80... 1.20 x U n Frequency rating Hz 50/60 Frequency range Hz 45... 65 Operating features System start - automatic at connection of auxiliary power LAN Server data addressing - by means of it IP address Data transfer speed LAN limited Mbit/s 100 User interface for setup and management Web browser W3C HTML 4.01 compliant Suitable for both single-phase and three-phase energy meters yes LAN Interface HW interface - RJ 45 connector SW protocol - TCP/IP Interface to measuring instrument HW interface optical IR n 2 (Tx, Rx) SW protocol - proprietary Safety acc. to IEC 60950 Degree pollution - 2 Overvoltage category - II Working voltage V 300 Clearance mm 4 Creepage distance mm 4 Test voltage impulse (1,2/50 µs) peak value on AC power supply kv 4 50 Hz 1 min kv 4 Housing material flame resistance UL 94 class V0 Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ0 Terminal capacity solid wire min. (max.) mm 2 0.15 (2.5) stranded wire with sleeve min. (max.) mm 2 0.15 (4) Environmental conditions Operating temperature C 0... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.25 Protection class acc.to IEC 60950 - II Degree of protection housing when mounted in front IP20 Dimensions (mm) 192

M-Bus interface EMECMBUS Additional communication modules for Energy-meter, Network analyzer and Power-meters Additional module for M-Bus connection for energy, power, V, I, cosϕ, frequency M-Bus according to EN1434 Suitable for both single-phase and three-phase energy meters 1 DIN module wide (18 mm) EMECMBUS Data in compliance with EN 13757-1-2-3, IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2 General characteristics Housing DIN 43880 DIN 1 module Mounting EN 60715 35 mm DIN rail Depth mm 70 Power supply Power supply - through bus connection Operating features Suitable for both single-phase and three-phase energy meters yes M-bus interface HW interface - 2 screw clamps SW protocol - M-Bus according to EN1434 Baudrate Baud 300-9600 Interface to measuring instrument HW interface optical IR n 2 (Tx, Rx) SW protocol - proprietary Safety acc. to IEC 60950 Degree pollution - 2 Overvoltage category - II Working voltage V 24... 36 Clearance in equipment mm 1.5 on PCB (not coated) mm 1.5 Creepage distance mm 2.1 Test voltage impulse (1,2/50 µs) peak value kv 2.5 50 Hz 1 min kv 1.35 Housing material flame resistance UL 94 class V0 Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ0 Terminal capacity solid wire min. (max.) mm 2 0.15 (2.5) stranded wire with sleeve min. (max.) mm 2 0.15 (4) Environmental conditions Operating temperature C 0... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.25 Protection class acc.to IEC 60950 - II Degree of protection housing when mounted in front IP20 Dimensions (mm) 193

Modbus interface RTU and Ascii EMECMODB Additional communication modules for Energy-meter, Network analyzer and Power-meters Additional module for Modbus RTU and Ascii connection for energy, power, V, I, cosϕ, frequency Protocols Modbus Ascii - Modbus RTU Suitable for both single-phase and three-phase energy meters 1 DIN module wide (18 mm) EMECMODB Data in compliance with IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2 General characteristics Housing DIN 43880 DIN 1 module Mounting EN 60715 35 mm DIN rail Depth mm 70 Power supply Auxiliary voltage rating U n VAC 230 Auxiliary power rating W 10 Auxiliary voltage range VAC 0.80... 1.20 x U n Frequency rating Hz 50/60 Frequency range Hz 45... 65 Operating features Protocol selectable by software - Modbus RTU or Ascii Suitable for both single-phase and three-phase energy meters yes Modbus interface HW interface RS-485 terminals n 3 (+/-, cable shield) Input resistance UL (kω) 1 (12) Termination resistance Ω 80 SW protocol SW selectable - Modbus Ascii - Modbus RTU Data transfer speed SW selectable baud 38.400 - default 19200 Parity - none/even - default: none Addressing - 1 to 247 Interface to measuring instrument HW interface optical IR n 2 (Tx, Rx) SW protocol - proprietary Safety acc. to IEC 60950 Degree pollution - 2 Overvoltage category - II Working voltage V 300 Clearance mm 4 Creepage distance mm 4 Test voltage impulse (1,2/50 µs) peak value on AC power supply kv 2.5 on telecommunication network kv 1.5 50 Hz 1 min kv 2.5 Housing material flame resistance UL 94 class V0 Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ0 Terminal capacity solid wire min. (max.) mm 2 0.15 (2.5) stranded wire with sleeve min. (max.) mm 2 0.15 (4) Environmental conditions Operating temperature C 0... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.25 Protection class acc.to IEC 60950 - II Degree of protection housing when mounted in front IP20 Dimensions (mm) 194

BASIC Energy-meters three-phase, transformer 5 A, EME Active energy-meters for three-phase alternating current with either 2, 9 digits digital counters. These meters have 1 S0 output generating pulses for remote processing of the instantaneous energy active measurements for 2 tariffs. Three-phase digital active energy-meter with connection by CT.../5 A, up to 10.000/5 A - 0.05-5 (6) A - 2 tariffs - 2 S0 For transformer.../5 A For transformer primary current of 5 A to 10.000/5 A. Input is in 5 A increments 9 digits - 4 display for energy values indication Detection of connection errors (phase transposition and phase missing) Accuracy class 1 for active energy and power according to EN 50470-3 (B) Most attractive operating range current (I st... I max ), for connection by CT.../5 A = 0.003... 5 A Energy register zero setting (not for MID types) Energy register for import and export Sealable terminal covers 4 DIN modules wide (72 mm) EME3PCTB EME3PCTBMID CT connection till 10.000/5 A Data in compliance with EN 50470-1, EN 50470-3 and EN 62053-31 General characteristics Housing DIN 43880 DIN 4 modules Mounting EN 60715 35 mm DIN rail Depth mm 70 Reference standard active energy - EN 50470-1-3 pulse output EN 62053-31 Operating features Connectivity to three-phase network n wires 4 Storage of energy values and configuration digital display (EEPROM) - yes Display tariffs identifier for active energy n 2 T1 and T2 Supply Rated control supply voltage U n VAC 230 Operating range voltage V 184... 276 Rated frequency f n Hz 50 Rated power dissipation (max. for phase) P v VA (W) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V 480 1 second: phase/phase V 800 continuous; phase/n V 276 1 second: phase/n V 300 Current I max continuous A 6 momentary (0,5 s) A 120 momentary (10 ms) A - Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err Display type LCD n digits 9 (2 decimal) digit dimensions mm x mm 6.00 x 3 Active energy: 1 display, 9 digit - 2 tariffs min. measuring energy kwh 0.01 + display import or export (arrow) max. measuring overflow kwh 9999999.99 Instantaneous tariff measurement 1 display, 1-digit - T1 or T2 Transformer primary current A 5... 10.000 Display period refresh s 1 Measuring accuracy Active energy acc.to EN 50470-3 class 1 B Measuring input Type of connection transformer.../5 A Voltage U n phase/phase V 400 phase/n V 230 Operating range voltage phase/phase V 319... 480 phase/n V 184... 276 Current I ref A - Current I n A 5 Current I min A 0.05 Operating range current (I st... I max ) direct connection A - transformer connection (CT) A 0.003... 6 195

EME3PCTB EME3PCTBMID CT connection till 10.000/5 A Measuring input Transformer current primary current of the transformer A 5...10.000 smallest input step adjustment in 5 A steps A 5 Frequency Hz 50 Input waveform - sinusoidal Starting current for energy measurement (I st ) ma 3 Pulse output S0 acc.to EN 62053-31 Pulse output for active and reactive energy T1 and T2 yes Quantity pulse output for direct connection 63 A Imp/kWh - depending on the transf. factor Imp/kWh 100-10-1 Pulse duration ms 30 ±2 ms Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 10.000 Safety acc. to EN 50470-1 Indoor meter - yes Degree of pollution - 2 Operational voltage V 300 AC voltage test (EN 50470-3, 7.2) kv 4 Impulse voltage test 1.2/50 µs-kv 6 Protection class (EN 50470) class II Housing material flame resistance UL 94 class V0 Safety-sealing between upper and lower housing part - no yes Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ1 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (4) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (4) Environmental conditions Mechanical environment - M1 Electromagnetic environment - E2 Operating temperature C -10... +55 Limit temperature of transportation and storage C -25... +70 Relative humidity (not condensation) % 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection 196

Connection through CT.../5 A till 10.000/5 A Connection diagrams Dimensions (mm) Wire N needs to be connected to the meter. Instructions for the connection of transformer counters A Miniature Circuit Breaker of 6A is recommended. Current transformers must not be operated with open terminals since dangerous high voltages might occur which may result in personal injuries and property damage. In addition to this, the transformers are exposed to thermal overload. 197

BASIC Energy-meters three-phase, direct 63 A, EME Active energy-meters for three-phase alternating current with either 2, 9 digits digital counters. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active measurements for 2 tariffs. Three-phase digital active energy-meter with direct connection 0.25-5 (63) A - 2 tariffs - 2 S0 For direct connection 63 A 9 digits - display for 4 energy values indication Detection of connection errors (phase transposition and phase missing) Accuracy class 1 for active energy and power according to EN 50470-3 (B) Most attractive operating range current (I st... I max ), for direct connection 63 A = 0.015... 63 A Energy register zero setting (not for MID types) Energy register for import and export Sealable terminal covers 4 DIN modules wide (72 mm) EME3P63B EME3P63BMID direct connection 63 A direct connection 63 A Data in compliance with EN 50470-1, EN 50470-3 and EN 62053-31 General characteristics Housing DIN 43880 DIN 4 modules 4 modules Mounting EN 60715 35 mm DIN rail DIN rail Depth mm 70 70 Reference standard active energy - EN 50470-1-3 EN 50470-1-3 pulse output EN 62053-31 EN 62053-31 Operating features Connectivity to three-phase network n wires 4 4 Storage of energy values and configuration digital display (EEPROM) - yes yes Display tariffs identifier for active energy n 2 T1 and T2 T1 and T2 Supply Rated control supply voltage U n VAC 230 230 Operating range voltage V 184... 276 184... 276 Rated frequency f n Hz 50 50 Rated power dissipation (max. for phase) P v VA (W) 8 (0.6) 8 (0.6) Overload capability Voltage U n continuous; phase/phase V 480 480 1 second: phase/phase V 800 800 continuous; phase/n V 276 276 1 second: phase/n V 300 300 Current I max continuous A 63 63 momentary (0,5 s) A - - momentary (10 ms) A 1900 1900 Display (readouts) Connection errors and phase out discernible from phase-sequence indication - PHASE Err PHASE Err Display type LCD n digits 9 (2 decimal) 9 (2 decimal) digit dimensions mm x mm 6.00 x 3 6.00 x 3 Active energy: 1 display, 9 digit - 2 tariffs min. measuring energy kwh 0.01 0.01 + display import or export (arrow) max. measuring overflow kwh 9999999.99 9999999.99 Instantaneous tariff measurement 1 display, 1-digit - T1 or T2 T1 or T2 Transformer primary current A - - Display period refresh s 1 1 Measuring accuracy Active energy acc.to EN 50470-3 class 1 B B Measuring input Type of connection direct direct Voltage U n phase/phase V 400 400 phase/n V 230 230 Operating range voltage phase/phase V 319... 480 319... 480 phase/n V 184... 276 184... 276 Current I ref A 5 5 Current I n A - - Current I min A 0.25 0.25 Operating range current (I st... I max ) direct connection A 0.015... 80 0.015... 80 transformer connection (CT) A - - 198

Measuring input Transformer current EME3P63B direct connection 63 A primary current of the transformer A - - smallest input step adjustment - - A - - EME3P63BMID direct connection 63 A Frequency Hz 50 50 Input waveform - sinusoidal sinusoidal Starting current for energy measurement (I st ) ma 15 15 Pulse output S0 acc.to EN 62053-31 Pulse output for active and reactive energy T1 and T2 yes yes Quantity pulse output for direct connection 63 A Imp/kWh 500 500 depending on the transf. factor Imp/kWh - - Pulse duration ms 30 ±2 ms 30 ±2 ms Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) 5... 230 ±5% (5... 300) Permissible current pulse ON (max. 230 V AC/DC) ma 90 90 Permissible current impuls OFF (leakage currrent max. 230 V AC/DC) µa 1 1 Optical interfaces Front side (accuracy control) LED Imp/kWh 1000 1000 Safety acc. to EN 50470-1 Indoor meter - yes yes Degree of pollution - 2 2 Operational voltage V 300 300 AC voltage test (EN 50470-3, 7.2) kv 4 4 Impulse voltage test 1.2/50 µs-kv 6 6 Protection class (EN 50470) class II II Housing material flame resistance UL 94 class V0 V0 Safety-sealing between upper and lower housing part - yes yes Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ2 PZ2 Type cage pulse output blade for slotted screw mm 0.8 x 3.5 0.8 x 3.5 Terminal capacity main current paths solid wire min. (max.) mm 2 1.5 (35) 1.5 (35) stranded wire with sleeve min. (max.) mm 2 1.5 (35) 1.5 (35) Terminal capacity pulse outlet solid wire min. (max.) mm 2 1 (4) 1 (4) stranded wire with sleeve min. (max.) mm 2 1 (2.5) 1 (2.5) Environmental conditions Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C -10... +55-10... +55 Limit temperature of transportation and storage C -25... +70-25... +70 Relative humidity (not condensation) % 80 80 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.075 ±0.075 Degree protectionhousing when mounted in front (terminal) - IP51*)/IP20 IP51*)/IP20 *) For the installation in a cabinet at least with IP51 protection 199