DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

Similar documents
DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

PZ-FLIM-110. Piezo Scanning FLIM System. Based on bh s Megapixel FLIM Technology. Complete FLIM Microscopes FLIM Upgrades for Existing Microscopes

Instrument response function. Left linear scale, right logarithmic scale. FWHM is 120 ps.

Non-Descanned FLIM Detection in Multiphoton Microscopes

BDS-SM Family Picosecond Diode Lasers

BDS-SM Family Picosecond Diode Lasers

BDS-MM Family Picosecond Diode Lasers

Picosecond Light Sources

Time-Correlated Single Photon Counting Systems

Megapixel FLIM with bh TCSPC Modules

The DCS-120 Confocal Scanning FLIM System

Wide-Field TCSPC FLIM with bh SPC-150 N TCSPC System and Photek FGN Detector

Multiphoton FLIM with the Leica HyD RLD Detectors

TCSPC at Wavelengths from 900 nm to 1700 nm

Becker & Hickl GmbH. Technology Leader in Photon Counting

TCSPC for FLIM and FRET in Microscopy

An 8-Channel Parallel Multispectral TCSPC FLIM System

Becker & Hickl GmbH DCS-120. Confocal Scanning FLIM Systems. An Overview

Time Correlated Single Photon Counting Systems

IR Antibunching Measurements with id201 InGaAs Gated SPAD Detectors

User Handbook. DPC Channel Photon Correlator

NUV and Blue ps Diode Lasers

High Performance Photon Counting. User Manual PML-16-C. 16 Channel Detector Head for Time-Correlated Single Photon Counting. Becker & Hickl GmbH

Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617)

PCS-150 / PCI-200 High Speed Boxcar Modules

Ultraviolet and Blue Picosecond Diode Laser Modules

Multi-wavelength TCSPC lifetime imaging Wolfgang Becker a, Axel Bergmann a, Christoph Biskup b, Thomas Zimmer b, Nikolaj Klöcker c, Klaus Benndorf b

WHITE PAPER FAST PROTEIN INTERACTION BINDING CURVES WITH INO S F-HS CONFOCAL MICROSCOPE

Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617)

SHM-180 Eight Channel Sample & Hold Module

FLIM Protocol. 1. Install IRF sample on the microscope using the stage insert. IRF sample options include urea crystals or BBO crystal.

Time-Correlated Single Photon Counting

Solea. Supercontinuum Laser. Applications

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Practical work no. 3: Confocal Live Cell Microscopy

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Zeiss 780 Training Notes

Simultaneous Phosphorescence and Fluorescence Lifetime Imaging by Multi-Dimensional TCSPC and Multi-Pulse Excitation

PML Channel Detector Head for Time-Correlated Single Photon Counting

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

The Zeiss AiryScan System, Confocal Four.

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Microscopy from Carl Zeiss

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

Leica TCS SP8 Quick Start Guide

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

BASICS OF CONFOCAL IMAGING (PART I)

pulsecheck The Modular Autocorrelator

3D light microscopy techniques

TCSPC measurements with the InGaAs/InP Single- photon counter

LSM 710 Confocal Microscope Standard Operation Protocol

taccor Optional features Overview Turn-key GHz femtosecond laser

LSM 780 Confocal Microscope Standard Operation Protocol

Things to check before start-up.

Components of confocal and two-photon microscopes

APE Autocorrelator Product Family

Leica TCS SP8 Quick Start Guide

Setting up High Gain Detector Electronics for TCSPC

Multi-channel imaging cytometry with a single detector

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Technical Benefits of the

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

ChromoFlex. The flexibility of four colour multiphoton imaging. Experts in Electrophysiology & Imaging

Zeiss 880 Training Notes Zen 2.3

LABORATÓRIUMI GYAKORLAT SILLABUSZ SYLLABUS OF A PRACTICAL DEMONSTRATION. financed by the program

ZEISS LSM510META confocal manual

Multifluorescence The Crosstalk Problem and Its Solution

LSM 510 META in Chang Gung University

Shreyash Tandon M.S. III Year

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Detectors for High-Speed Photon Counting

Zeiss LSM 780 Protocol

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

DDG-210 Preliminary Manual Version A4

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging.

Zeiss LSM 880 Protocol

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Spider Pulse Characterization

ScanArray Overview. Principle of Operation. Instrument Components

Leica SPEII confocal microscope. Short Manual

Basics of confocal imaging (part I)

Confocal Microscopy. Kristin Jensen

Wavelength LDH - P / D - _ / C / F / FA / TA - N - XXX - _ / B / M / L / XL. Narrow linewidth (on request) Tappered amplified

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

OCF-401 Optical Constant Fraction Discriminator

Alba v5 Laser Scanning Microscope

Nikon A1R. Multi-Photon & Laser Scanning Confocal Microscope. Kyle Marchuk Adam Fries Jordan Briscoe Kaitlin Corbin. April 2017.

Supplemental Method Information Zeiss LSM710

FEMTOSMART. Benefits. Features

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Contents. Introduction

GenePix Application Note

3 Choose the Channels button and set the Channel Settings. Set the Pinhole to 1 Airy unit.

Transcription:

Based on bh s Multidimensional Megapixel FLIM Technology Complete Laser Scanning FLIM Microscopes FLIM Upgrades for Existing Conventional Microscopes Multidimensional TCSPC technique High throughput dual-channel parallel TCSPC architecture Single-channel, dual-channel, and multispectral FLIM High efficiency GaAsP hybrid detectors 16-channel multi-wavelength GaAsP detector Compact electronics, controlled by laptop computer Fully integrated scanner control Two fully confocal detection channels Confocal detection Suppression of out-of-focus light Excellent contrast and resolution Fast beam scanning by galvanometer mirrors Channel separation by dichroic or polarising beamsplitters Excitation by two bh BDL picosecond diode lasers Laser wavelengths 375nm, 405 nm, 445 nm, 473 nm, 488 nm, 515 nm, 640 nm, 685 nm, 785 nm Compatible with Ti:Sa and supercontinuum lasers Becker & Hickl GmbH Nahmitzer Damm 30 12277 Berlin, Berlin Tel. +49 / 30 / 787 56 32 Fax. +49 / 30 / 787 57 34 email: info@becker-hickl.com www.becker-hickl.com

Megapixel FLIM Technology Extremely large images Image size up to 2048 x 2048 pixels Record a large number of cells under identical conditions Select cells of interest from recorded data Fast Preview Function Interactive Scanner Control Easy focusing and sample positioning Easy scan area selection No stop of scanner required Easy Change of Instrument Configuration Select system configuration from list of Predefined Setups Change instrument configuration on a single mouse click Fast Scanning 0.5 s snapshots every 1 s Bacteria catched in flight Dual-Channel FLIM Separate filters and pinholes Fully parallel TCSPC channels High data throughput Short acquisition times No amplitude or lifetime crosstalk

Multi-Wavelength FLIM Simultaneous detection in 16 wavelength channels GaAsP multi-wavelength detector No wavelength scanning, no time gating Near-ideal recording efficiency Maximum SNR at minimum sample exposure Laser Wavelength Multiplexing Pixel, line, or frame multiplexing Separation of fluorophores by excitation and emission wavelength Z Stack FLIM Automatic FLIM acquisition in consecutive Z planes Multiphoton FLIM Ultra-high sensitivity combined with deep-tissue imaging capability Simultaneous, fully parallel detection in two wavelength channels Simultaneous FLIM and SHG imaging Extraction of SHG component from FLIM data Near-Infrared FLIM Confocal FLIM with NIR fluorophores Excitation by ps diode lasers, 640 to 785nm, by supercontinuum laser, or by Ti:Sa laser Large penetration depth No autofluorescence background

Multi-Exponential FRET Analysis FRET, separation of interacting and noninteraction donor Self-calibrating FRET Correct conventional FRET efficiencies Time-Series FLIM Time-series as fast as 2 images per second Physiological effects Chlorophyll transients Temporal Mosaic FLIM Time series at rates down to 40 ms per image Record Ca 2+ transients by FLIM Record chlorophyll transients FLITS Resolve transient lifetime effects down to 1 millisecond by line scanning Record photochemical chlorophyll transients Record Ca 2+ transients in live neurons PLIM Simultaneous recording of phosphorescence and fluorescence lifetime images Record metabolic effects by FLIM and track O 2 concentration by PLIM FCS High-efficiency by GaAsP hybrid detectors No afterpulsing peak Online calculation, online fit Time-gating for suppression of Raman light

SPCImage FLIM and PLIM Data Analysis Single, double, and triple-exponential decay analysis No IFR measurement required Display of lifetimes, amplitudes, intensities or ratios of decay parameters Histograms of lifetimes, amplitudes, intensities or ratios of parameters in regions of interest Phasor plot Direct interaction with SPCM instrument software Burst Analyzer Single-Molecule Data Analysis Identification of photon bursts from single molecules in parameter-tag data Calculation of intensity and lifetime histograms Calculation of single-molecule FRET intensities Advanced FCS calculation Time-gated FCS, selection of time windows in PIE data

System Components Lasers Scanner Detectors TCSPC Modules Scanner Control Available Wavelengths 375nm, 405 nm, 445 nm, 473 nm, 488 nm, 515nm, 640nm, 685nm, 785nm Repetition rates 20 MHz, 50 MHz, 80 MHz, CW Pulse width typ. 60 ps Intensity control, electronic 1:10 Beam correction optics Beam-profile and astigmatism correction Fibre coupling Single-mode, into Qioptiq fibre Power delivered into fibre: 405 nm: 1 mw, 440 nm: 0.4 mw, 473 nm: 0.4 mw, 488 nm: 0.4 mw Laser Multiplexing Within each pixel, line by line, or frame by frame, PIE Beam blanking During x and y flyback, via bh GVD-120 scan controller Laser inputs Point-Source Kineflex push-and click fibre manipulator Laser power regulation, optical Attenuators, 1:1 to 1:50 Laser beam combiner Dichroic mirror Scanner Close-coupled galvanometer mirrors Main beamsplitter Dichroic 420 nm, 450 nm, 490 nm, 405/473 nm 80:20 mirror Secondary beamsplitter Beamsplitter wheel. Dichroics 510 nm, 560 nm, polarising beamsplitter, 100% channel 1, 100% channel 2. Other dichroics on request Pinholes From approx. 0.5 AU to 10 AU 1) Filters Filter sliders, standard filters LP 435, LP 485, BP 480/40, BP535/30, BP 620/60 GaAsP hybrid detectors HPM-100-40 hybrid PMT modules. IRF width 130 ps 2) Standard PMTs PMC-100-1 or -20 cooled PMT modules. IRF width 180 ps 2) High-speed MCP-PMTs R3809U-50 MCP PMTs, IRF width 70 ps 2) Multi-wavelength detector bh MW FLIM GaAsP detector. Please see individual data sheet. Detector control Gain, cooling, overload shutdown, via bh DCC-100 detector controller 1 SPC-150 TCSPC module Single-channel FLIM systems with one HPM-100-40, one PMC-100, or one multispectral FLIM detector 2 SPC-150 TCSPC modules Dual-channel FLIM systems with two HPM-100-40, two PMC-100, or two multispectral FLIM detectors High-speed FLIM systems Scan controller bh GVD-120 (single-slot PCI module) Generation of scan signals Hardware, digital signal synthesis Image size 16 x 16 to 2048 x 2048 Max. scan rate, time/frame 128x128: 0.32s, 256x256: 0.6s, 512x512: 1.5s 3) Zoom factor 1:1 to 1:10 4) Beam blanking During flyback, on / off selectable Laser multiplexing Pixel by pixel, line by line, or frame by frame Beam park function any location within scan area Scan control software Integrated in standard SPCM TCSPC software Galvo driver amplifier bh GVP-120 Electronics box and system computer Lap-top PC with PCI-extension box Also available: Extension box contains: 1 or 2 SPC-150 TCSPC modules 1 GVD-120 scan controller 1 DCC-100 detector controller SPC, GVD, and DCC modules installed in standard PC 1) depends on microscope lens used 2) Includes pulse width of ps diode laser 3) maximum scan rate depends on zoom factor 4) useful zoom range depends on microscope

TCSPC Technique (Standard DCS-120 FLIM Systems) Single-Detector Systems Dual-Detector Systems Multi-Spectral Systems TCSPC system Simple-Tau 150 Simple-Tau 152 Simple-Tau 150 Components Lap-top computer Lap-top computer Lap-top computer PCI extension box PCI extension box PCI extension box SPC-150 TCSPC module Two SPC-150 TCSPC modules SPC-150 TCSPC module DCC-100 detector controller DCC-100 detector controller DCC-100 detector controller Saturated count rate 10 MHz 20 MHz 10 MHz Sustained count rate Scan Sync In mode 10 MHz 20 MHz 10 MHz FIFO Imaging Mode 4 MHz 4 MHz 4 MHz Scan rate any any any Scan synchronisation via pixel clock, line clock and frame clock in all imaging modes Zoom automatic zoom with zoom in microscope Online display in programmable intervals, 1 second or larger Max. image size, 64 bit SPCM software pxl x x pxl y x t 2048x2048x256 2x 2048x2048x256 16x 512x512x64 (examples) 1024x1024x1024 2x 1024x1024x1024 16x 512x512x256 512x512x4096 2x 512x512x4096 16x 256x256x1024 256x256x4096 256x256x4096 Requirements to Microscope Confocal FLIM MP FLIM Side port of microscope available Lamp port or NDD port available Other FLIM configurations Please note that the bh FLIM systems are highly modular. Therefore a large number of different FLIM system configurations are possible. Please see [1] for details or contact bh. Literature: [1] DCS-120 confocal scanning FLIM systems, user handbook. www.becker-hickl.com [2] DCS-120 confocal scanning FLIM systems. Overview brochure. www.becker-hickl.com [3] The bh TCSPC Handbook, www.becker-hickl.com [4] W. Becker, Advanced Time-correlated single photon counting techniques. Springer 2005 [5] The HPM-100-40 hybrid detector. Application note, available on www.becker-hickl.com Please contact bh for printed copies

International Sales Representatives US: Boston Electronics Corp tcspc@boselec.com www.boselec.com UK: Photonic Solutions sales@photonicsolutions.co.uk www.photonicsolutions.co.uk Japan: Tokyo Instruments Inc. sales@tokyoinst.co. jp www.tokyoinst.co.jp China: DynaSense Photonics Co. Ltd. info@dyna-sense.com www.dyna-sense.com