- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Similar documents
K3P ENG.qxd 23/10/ Pagina 1

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

Temperature Controller

High Performance Process & Temperature Controllers

Analogue temperature controllers

170.IU0.LFS.0B /B r USER MANUAL LFS

7SD/7SH/7SM Temperature Controllers

Excellent low-cost Process & Temperature Controllers

ONE CALIBRATOR ONLY MAIN FEATURES:

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

MICRO-CONTROLLER X (48 48 mm)

PMW. Serial Interface INSTRUCTION MANUAL MICROPROCESSOR BASED CONTROLLER

MEMOCAL 2000/2000S. Hand-held calibrator

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line

DC1010/DC1020/DC1030/DC1040

MICRO-CONTROLLER X (96 96 mm)

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

Passive TX, 2 wires, ma 0/ mv, 0/1... 5V, 0/ V ma (active) Pt1000 Pt100 TC. 2.2 Inputs

MICRO-CONTROLLER X (48 96 mm)

PROCESS & TEMPERATURE CONTROLLERS

Instruction Manual (1/8 DIN) Controller With ma output.

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

PID CONTROLLERS LT SERIES

General Specifications

I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output

Temperature Controls

Fuzzy Temperature Controllers E5AF

General Purpose Digital Controllers Specifications


170.IU0.Q , r USER MANUAL EWTQ915 EWTQ985

APPENDIX APPENDIX A 1

Instruction Manual IN February Model 7SF

General Specifications

K Series. Controllers / mini-programmers with wattmeter function and independent timer

DPS INSTRUCTION MANUAL DIGITAL PANEL INDICATOR. 2 rue René Laennec Taissy France Fax: , Tel :

General Specifications

Temperature Controllers E5 J

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

General Specifications

General Specifications

170.IU0.XKP.0C r USER MANUAL PKP MKP

General Specifications

General Specifications

Series F4P Communications Guide

General Specifications

DIGITAL PROGRAM CONTROLLER

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

MPS SERIES. INSTALLATION and TECHNICAL MANUAL MPS 4 MPS 5 MPS 9 4 PV

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

SHIMADEN PROGRAM CONTROLLER

C C1 C2 AL1 AL2 AL3. Micro-controller X. Model: PXR SEL PXR-4. Operation Manual. ECNO:406a

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

8003 1/8 DIN Temperature Controller

Process and Temperature Controllers

Table of Contents Panel Mount Controllers Analog Series C-Series Controller Software Legacy Series Power Controllers Analog Series P-Series

Process displays For standard signals, temperature, resistance measurement

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

Double action controller with analogue output 1/4 DIN - 96 x 96 mm gammadue series Q3 line

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

REX-F400 REX-F700 REX-F900

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

658 Current to Position Converters

DP2000 ORDERING GUIDE To Order MODEL NO.

MODEL: TC10EM. Temperature Controller TC10 Series

Introduction To Temperature Controllers

Digital Temperature Controller

Digital Temperature Controller

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

CT325 Miniature DC Temperature Controller

CompoBus/D-type Digital Controller

PROGRAMMABLE CONTROLLER

Description of functions Controller system VR660 / A200R

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

SHIMADEN DIGITAL INDICATORS

Digital Panel Meter Glossary

FC Series Signal Conditioners

DIGITAL INDICATING CONTROLLER

N2000S UNIVERSAL PROCESS CONTROLLER FOR SERVO POSITIONING OPERATING MANUAL. (Manual Key): toggles the AUTO/MANUAL mode.

AKP-AKU DIGITAL PANEL METER

SRC-110 Series Zone Controllers with Modbus RTU

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

170.IU0.TMS /D r USER MANUAL TMS

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

SHIMADEN DIGITAL INDICATOR

ControlMaster CM10, CM30, CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

UL CONDITIONS OF ACCEPTABILITY

Micro-controller X SV C1 C2 AL1 AL2 SEL. Model: PXR3. Operation Manual TN5A2704-E

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

General Specifications

Energy Management Energy meters Type EM2-DIN

SHIMADEN DIGITAL CONTROLLER

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Digital indicator for panel mounting With multi-function input Model DI25

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

Energy Management Modular Smart Power Transducer Type SPT-90

Transcription:

ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS (10 OPTIONAL MKC) - 3x LOGIC INPUTS (8 OPTIONAL MKC) - 24V DC TRANSMITTER POWER SUPPLY - RS 485 MODBUS SERIAL COMMS OPTION - OPC BASED GRAPHICAL CONFIGURATION SOFTWARE

OVERVIEW A wide range of hardware combinations and special software functions make these instruments highly flexible and suitable for a wide range of advanced control applications. Designed to offer outstanding control performance and provide comprehensive solutions for a wide variety of applications such as food processing, steam control, flow control, research-heating equipment requiring precision heat/cool control and process protection alarms. The custom display provides a complete view of the process. Universal thermocouple, RTD or process linear input coupled with a responsive, SMART auto-tuning PID control algorithm that is equipped with special functions including soft start and non linear cooling. A complete set of process protection alarm functions, high and low limit, band and deviation are included. Optional features include: CT input- HBD, OFD Servo valve positioner, (ma) linear control or retransmission outputs, ModBus communication interface option. CONFIGURATION PROGRAM The configuration software simplifies the instrument configuration, parameter adjustment and program editing. A complete instrument configuration may be saved from, and downloaded to the instrument providing a quick and reliable method to maintain instrument settings. SPLIT RANGE OF THE OUTPUT Allows two different physical outputs, (two different actuators) to be driven from the same control output. Bias and gain settings for each output may be independently set to achieve optimal control precision. This feature may be used to improve flow control and reduce energy consumption when using two control valves or variable speed pumps of different size, as illustrated in the diagram. Power output Power output 100% 100% Measure Output calculated by PID algorithm Output A Output B 100% Out A Out B Measure Output calculated by PID algorithm Output A Output B Real Output (it is the sum of the two outputs) Measure SQUARE ROOT EXTRACTION ON THE MEASURED VALUE A square root extraction function is available to calculate flow with a standard DP transmitter without additional signal conditioning hardware.

PREPROGRAMMED OUTPUT CHARACTERISTICS Quick opening and equal percentage valve flow characteristic are automatically compensated by the output linearisation facility. This function linearises the ratio between flow rate and valve travel in order to obtain a better control of the process. Maximum flow percentage 100% 80% 60% 40% Quick opening Linear 20% Equal Percentage 0% 20% 40% 60% 80% Rated travel percentage 100% ALARM ON THE OUTPUT VALUES The control output percentage is monitored by a configurable process alarm. Using this method it is possible to simplify the control of the process. In the example shown, the instrument is controlling a process by driving an airflow valve. The airflow generator uses 3 fans; the first one is always ON while the second and third are turned ON when the power output reaches the programmed value [33 % (AL 1) and 66% (AL 2)]. This solution reduces power consumption and improves process control. Power output 100% AL2 AL1 AL2 AL1 AL2 OP5 3 2 Output 5 Measure 1 FANS PROCESS PROTECTION ALARMS Process (high or low limit), Band and Deviation alarm outputs are available with the additional flexibility of latching and masking functions until the process variable reaches the alarm threshold plus or minus hysteresis. Band and deviation alarms are also masked after a set point change until process variable reaches the alarm threshold. The alarm latching function holds the alarm on until it is acknowledged. OFD FUNCTION - OUTPUT FAILURE DETECTION (optional) Using the CT input the, output failure detection function monitors the current in the load driven by the output 1. Load and actuator protection is provided in the following way: 1. During the ON period of the output, the instrument measures the current through the load and it generates an alarm condition if this current is lower than a pre-programmed threshold. A low current shows a partial or total break down of the load or actuator SSR. 2. During the OFF period of the output, the instrument measures the leakage current through the load and it generates an alarm condition when this current is higher than a pre-programmed threshold value. A high leakage current shows a short circuit of the actuator.

PRODUCT SPECIFICATIONS Case: polycarbonate Self extinguishing degree: according to UL 746 C. Front protection: designed and tested for IP 65 and NEMA 4X for indoor locations (when panel gasket is installed). test perfomed in accordance with IEC 529, CEI 70-1 and NEMA 250-1991 STD. Rear terminal board: 32 screw terminals. Dimensions (according to DIN 43700): 48 x 96mm for PKC 96 x 96mm for MKC. Depth: 128mm. Weight: 500g for PKC. 600g for MKC. Power supply (switching type): from 100 to 240V AC 50/60 Hz (from -15% to 10%of the nominal value) or 24V DC/AC (10% of the nominal value). Power consumption: 15VA max. for PKC 16VA max. for MKC. Insulation: a double or reinforced insulation is guaranteed between the power supply and all the instrument inputs and outputs. Common mode rejection ratio: > 120dB @ 50/60Hz. Normal mode rejection ratio: > 60dB @ 50/60Hz. EMC/Safety: this instrument is marked CE.It conforms to council directives 89/336/EEC (reference harmonized standard EN 50081-2 and EN 50082-2), 73/23/EEC and 93/68/EEC (reference harmonized standard EN 61010-1). Sampling time: 125mSec for linear inputs 250mSec for TC or RTD. Accuracy: ± 0.2% f.s.v., @ 25 C and nominal power supply. Operating temperature: from 0 to 50 C. Storage temperature: from -20 to 70 C. Humidity: from 20% to 85% RH not condensing. MEASURING INPUTS All inputs are factory calibrated and selectable by the front keyboard. It is possible to apply a first order digital filter on the displayed value. The time constant of the filter may be programmed within 0 and 8 seconds. Thermocouples Line resistance compensation error: max. ± 0.1% of input span with input impedance <100Ω. Burn out: detection of the open input circuit (wire or sensor) with underrange or overrange selectable indication. Cold junction: automatic compensation for an ambient temperature between 0 and 50 C. Cold junction compensation error: 0.1 C/ C. Input impedance: > 1MΩ. Calibration: according to IEC 584-1. Standard range table TC type C F B 0/1820 32/3300 C 0/2300 0/4170 D 0/2300 0/4170 E -100/800-150/1470 G 0/2300 0/4170 L -100/900-150/1650 J -100/1000-150/1830 K -100/1370-150/2500 N -100/1400-150/2550 Nic -18% Mo 0/1200 0/2190 R -50/1760-60/3200 S -50/1760-60/3200 T -200/400-330/750 U -200/600-330/1110

RTD input Linear inputs (ma and V) Auxiliary input (optional) Type: Pt 100 3 wires connection. Calibration: according to DIN 43760. Line resistance: max. 20Ω/wire with no measurable error. Sensor break: detection of the sensor open circuit and of one or more wires open circuit. The instrument shows the short circuit indication when the sensor resistance is lower than 12Ω. Input linearization: programmable square root extraction. Readout: keyboard programmable from -1999 to 9999. Decimal figure: programmable in any position. Function: this input can be used as trim function, or as remote set point input Type: not isolated. Scaling: programmable from -1999 to 9999, the decimal figure is automatically positioned as for main input. Sampling time: 500 ms. ± 0.2% f.s.v. Accuracy: ± 1digit @ 25 C and nominal power supply voltage. Temperature drift: 300ppm/ C. Standard range table Standard range table Standard range table MKC.PKC RTD type C F Pt 100-200/850-330/1560 Pt 100-199.9/850.0-199.9/999.9 Input Impedance 0-20 ma >5 Ω 4-20 ma >5 Ω 0-60 mv >1MΩ 12-60 mv >1MΩ 0-5 V >200 kω 1-5 V >200 kω 0-10 V >400 kω 2-10 V >400 kω Input Impedance 0-20 ma >5 Ω 4-20 ma >5 Ω 0-5 V >200 kω 1-5 V >200 kω 0-10 V >400 kω 2-10 V >400 kω OUTPUTS These products may be supplied with up to 4 digital outputs (relay, SSR, TRIAC or servomotor drive) and up to 2 linear outputs (ma). Digital outputs (Out 1 and 2) Function: Type: Out 1 and 2 - Relay Relay type: Contact rating: singularly programmed as: - control output - alarm output - event output. relay, SSR or TRIAC. SPDT 3A @ 250V AC on resistive load. Out 1 and 2 - SSR Out 1 and 2 - TRIAC Type: Switching mode: Triac rating: not isolated voltage outputs. - Logic level 1: 14V @ 20 ma max. 24V @ 1 ma. - Logic level 0: < 0.5V isolated zero crossing type. from 50mA to 1A from 24V rms to 250V rms.

Out 3 and 4 Function: Type: Contact rating: singularly programmed as: - control output - alarm output - event output. - Servomotor drive (OUT 3 open, OUT 4 close). relay SPST. 3A @ 250V AC on resistive load. The OUT 3 and 4 commons are connected together with the same rear terminal. Servomotor output Type: two relays interlocked (OUT 3 and 4). Servomotor output type: - close loop - open loop with valve position indication only. - open loop without valve position indication. Feedback potentiometer input: from 100Ω to 10kΩ. Servomotor travel time: from 12 seconds to 3 minutes. Servomotor dead band: from 1% to 50% of the feedback span or of the valve travel time. Analog outputs (Out 5 and 6) Function: programmable as - control output - analog retransmission of the measured value - analog retransmission of the operative set point. Output type: isolated output programmable as: 0-20mA 4-20mA. Scaling: programmable from -1999 to 9999. Maximum load: 600Ω. Accuracy: 0.1% when it is used as control output. 0.05% when it is used as analog retransmission Filter: it is possible to apply a first order digital filter on the retransmitted value. The time constant of the filter may be programmed within 0 and 8 seconds. ADDITIONAL LOGIC I/O L MKC can be equipped with up to two additional card. Each card is equipped with four digital input and five relay output. The I/O status can be managed by serial link only.

CONTROL ACTION Algorithm: Types: Digital output types: Digital output control action: Analog output types: Servomotor output: Proportional band: Hysteresis (for ON/OFF control action): Integral time: Derivative time: Integral preload: Main output cycle time: Secondary output cycle time: Relative secondary output gain: Overlap/dead band: Output limiters: AUTO/MANUAL mode: PID SMART. - one control output (digital or analog output) - one control output split on two outputs (split range). - two control outputs. the outputs can be freely selected among analog, digital or servo. relay, SSR or TRIAC. proportional time linear (20mA). two relays interlocked. programmable from 0.5% to 999.0% of the input span. Setting a PB equal to 0 the control action becomes ON/OFF. programmable from 0.1% to 10.0% of the input span. programmable from 1 second to 20 minutes or excluded. programmable from 1 second to 10 minutes or excluded. programmable. - for one control output, from 0 to 100% of the output range. - for two control outputs, from -100% to 100% of the heating/cooling output range. from 1 second to 200 seconds. from 1 second to 200 seconds. programmable from 0.20 to 2.00 referred to proportional band. programmable from -20% (dead band) to 50% (overlap) of the proportional band. for main and/or secondary control outputs it is possible to set: - output high limits - output low limits - output max. rate of rise. selectable by front pushbutton or logic input. SET POINT These instruments are supplied with 4 local set points (selectable by external contact) and an input for the remote set point (RSP). The transfer from one set point to another may be done by a step transfer or by a ramp with two different programmable rates of rise (ramp up and ramp down). Set point limiters: Rate of change for set point variations: Digital filter: set point low limit and set point high limit programmable. from 1 to 200 digits per minute or excluded. it is possible to apply a first order digital filter on the measured value by the remote set point input (RSP). The time constant of this filter may be programmed within 0 and 8 seconds.

ALARMS Alarm action: Alarm function: Alarm reset: Alarm masking: direct or reverse action programable each alarm can be configured as process alarm, band alarm, deviation alarm or process alarm on the output value. automatic or manual reset programmable for each alarm. each alarm can be configured as masked alarm or standard alarm. Process alarm Band alarm Deviation alarm Operative mode: Threshold: Hysteresis: Operative mode: Threshold: Hysteresis: Operative mode: Thieshuld: Hysteresis: minimum or maximum programmable. programmable in engineering units within input range. programmable in engineering units from 1 to 200 digits inside or outside programmable. two thresholds are programmable: low - from 0 to -1000 digits. / high - from 0 to 1000 digits. programmable in engineering units from 1 to 200 digits high or low programmable. programmable from -1000 to 1000 digits. programmable in engineering units from 1 to 200 digits. Alarm on the main output values it is possible to obtain an alarm condition when the main control output is lower or higher than a programmed value. Operative mode: minimum or maximum programmable. Threshold: programmable from 0.1 to 100.0% of the output. Hysteresis: programmable in engineering units from 0.1 to 20.0% Alarm on the secondary output values Operative mode: Threshold: Hysteresis: it is possible to obtain an alarm condition when the secondary control output is lower or higher than a programmed value. minimum or maximum programmable. programmable from 0.1 to 100.0% of the output. programmable in engineering units from 0.1 to 20.0% of the output. EVENTS All digital outputs can be programmed as events. It is possible to set an event choosing among the following types: - error condition on the main input (overrange, underrange, open or short circuit) - error condition on the remote set point input (RSP) - error condition on both measuring inputs - auto/manual mode annunciator - local/remote set point annunciator

LOGIC INPUT (optional) Function: Input type: Active contact status: these instruments may be supplied with 3 logic inputs, each one can be programmed as: - set point selection (SP-SP2). - set point selection (SP3-SP4). - local/remote set point selection. - auto/manual mode selection. - output limiter activation. - data Hold of the measured value. - manual reset of alarms (acknowledgement) - direct/reverse control action. contact closure (voltage free). close or open programmable. SERIAL INTERFACE (optional) Type: RS 485 isolated. Protocol type: MODBUS, JBUS. Baud rate: programmable from 600 to 19200 BAUD. Byte format: 8 bit. Parity: even, odd or non - programmable. Stop bit: one. Address: from 1 to 255. Output voltage levels: according to EIA standard. AUXILIARY POWER SUPPLY (optional) An un-isolated auxiliary power supply option enables direct connection of a 2, 3 or 4-wire transmitters and eliminates the need for an additional, separate power supply unit. Type: Max. current: 24V DC ± 20% not isolated. 25mA. HOLD FUNCTION By an external contact it is possible to stop the input sampling keeping the last measured value frozen. SOFT START The Soft-start feature provides time based output power limit protection. Limiting the heater power during startup reduces potential thermal stress on the heating elements. Both the Soft-start time and temperature threshold are configurable. Temp SP Full output power normal PID control Soft start temp limit Output power limited Soft start time limit Time

DIMENSIONS AND PANEL CUT - OUT MKC 15 max 1.5 125 ERO ELECTRONIC 125 92 0 0.8 92 0 0.8 96 108.4 RESET FUNC RESET FUNC MKC 96 128 16 DIMENSIONS AND PANEL CUT - OUT PKC 15 max 1.5 60 ERO ELECTRONIC 125 92 0 0.8 45 0 0.6 108.4 96 RESET FUNC RESET FUNC PKC 48 128 16

REAR TERMINAL BLOCK MKC REAR TERMINAL BLOCK PKC IN COMMON IN1 IN2 IN3 IN4 56 45 57 46 58 47 59 48 60 49 IN COMMON IN5 IN6 IN7 IN8 OUT1 TRIAC OUT2 TRIAC LINE LOAD OUT1 SSR LINE LOAD OUT2 SSR OUT1 RELAY OUT2 RELAY NC 23 12 C 24 13 NO 25 14 NO 26 15 IN-CT C 27 16 OUT10 61 50 OUT15 NO 28 17 FEEDBACK OUT5 1 3 4 5 6 T/C RTD AUX IN OUT1 TRIAC LINE LOAD OUT1 SSR OUT2 TRIAC LINE LOAD OUT2 SSR OUT1 RELAY OUT2 RELAY NC 23 12 C 24 13 NO 25 14 NO 26 15 IN-CT C 27 16 NO 28 17 FEEDBACK OUT5 1 T/C 3 4 5 6 RTD AUX IN OUT11 OUT12 OUT13 OUT14 OUT COMMON 62 51 OUT16 63 52 OUT17 64 53 OUT18 65 54 OUT19 66 55 OUT COMMON MOTOR AC OUT3 RELAY OUT4 RELAY PWR LINE NO 29 18 C 30 19 OUT6 C/C NO 31 20 B/B N 32 21 A/A L 33 22 RS485 7 8 9 10 11 DIG3 DIG2 DIG1 24V 25mA AUX PWS MOTOR AC OUT3 RELAY OUT4 RELAY PWR LINE NO 29 18 C 30 19 OUT6 C/C NO 31 20 B/B N 32 21 A/A L 33 22 RS485 7 8 9 10 DIG3 11 DIG2 DIG1 24V 25mA AUX PWS

HOW TO ORDER MODEL INPUT OUT 1 and OUT 2 OUT 3 and OUT 4 OUT 5 and OUT 6 OPTIONS POWER SUPPLY MKC 1/4 DIN 1 main Aux-in. Logic inputs 11 two relay outputs 0 not provided 0 not provided 0 not provided 3 100/240V AC PKC 1/8 DIN 5 main OFD (or Feedback) 44 two TRIAC outputs 1 two relay outputs 5 two ma outputs 1 aux.pws 5 24V AC/DC 6 main Aux-in. Logic inputs OFD (or Feedback) 61 one SSR one relay output 2 two relay outputs interlockable by jumper 7 One ma output (Out 5) 2 RS485 Aux. PWS 9 main 66 two SSR outputs 3 RS485 6* RS485 4 logic inputs 5 Digital outputs 7* RS485 8 logic inputs 10 Digital outputs (*) MKC only HOW TO ORDER Current transformer (for instrument with OFD option only) DIMENSIONS CTR MODEL CTR current transformer PRIMARY CURRENT 1 10A 2 25A 3 50A 4 100A CTR ERO ELECTRONIC VIA XXIV MAGGIO 22070 GUANZATE (CO) ITALY TEL. 39 031 975 111 FAX. 39 031 977 512 SALES@EROELECTRONIC.COM - WWW.EROELECTRONIC.COM ERO ELECTRONIC a division of EUROTHERM S.r.l. A170.CAT.MKC.00E