P.O. Box 27 4300 AA Zierikzee The Netherlands Tel. +31 111 413656 Fax. +31 111 416919 www.deltapowersupplies.com DELTA ELEKTRONIKA B.V. SM 6000 - Se ries 6000 W DC POWER SUP PLIES Three phase input Mod els Volt age range Cur rent range SM 15-400 0-15 V 0-400 A SM 30-200 0-30 V 0-200 A SM 45-140 0-45 V 0-140 A SM 60-100 0-60 V 0-100 A SM 70-90 0-70 V 0-90 A SM 120-50 0-120 V 0-50 A SM 300-20 0-300 V 0-20 A SM 600-10 0-0 - Features ctuvus safety ap proval De signed for long life at full power Ex cel lent dy namic re sponse to load changes Pro tected against all over load and short cir cuit con di tions EMC sur passes CE re quire ments: low emis sion & high im mu nity Low au di ble noise: tem per a ture con trolled fans Avail able op tions: an a log & dig i tal In ter faces, High Speed Pro gram ming, Dig i tal Encoders, Se quencer, Power Sink etc. Functionalities Mas ter/slave par al lel and se ries op er a tion with volt age and cur rent shar ing Stack ing is al lowed, space be tween units is not re quired High power sys tem con fig u ra tion from mul ti ple units 19" rack mount ing or lab o ra tory use (feet in cluded) Re mote sens ing Interlock
DELTA ELEKTRONIKA BV SM6000 Output volt age cur rent Input AC 3 phase, 48-62 Hz for use at 380 V, 400 V, 415 V nom i nal line - line volt age SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM600-10 0-15 V 0-400 A 0-30 V 0-200 A 0-45 V 0-140 A 0-60 V 0-100 A 0-70 V 0-90 A 0-120 V 0-50 A 0-300 V 0-20 A 0-0- Option P165 for use at 440 V, 480 V (USA) (op er ates from 360 V, but at de rated out put, 5300 W@360 V) cur rent (400 V / 3 ph, full load) power fac tor, 100%, 50% load 10.2 A 10.3 A 10.4 A 9.9 A in ter nal fuses standby in put power (V o =I o =0) standby in put power (V o =V max ) 130 W 130 W 120 W Ef fi ciency 400 V AC, 3 ph in put, full load 87 % 89 % 90 % 89 % 89 % 89 % 89 % 89 % Reg u la tion Load 0-100% Line AC (ex ter nal volt age sense) Load 0-100% Line AC (in ter nal volt age sense, af ter warm-up) Rip ple + noise rms (BW=300 khz) p-p (BW=50 MHz) rms (BW=300 khz) p-p (BW=50 MHz) -rip ple at full load Temp. coeff., per C Sta bil ity af ter 1 hr warm-up dur ing 8 hrs t amb = 25 ± 1 C, V in = 400 V AC in ter nal volt age sens ing for -stab. 2. 0. 24 ma 4 ma 0.8 mv 8 mv 100 ma 300 ma 0. 12 ma 2 ma 1 mv 8 mv 20 ma 60 ma 1 mv 9 ma 1.5 ma 1. 8 ma 25 ma 6 ma 1 ma 10 ma 35.10-6 60.10-6 5.10-5 10.10-5 5 ma 1 ma 10 ma 8 mv 0.5 ma 3 mv 2 (20 mv @ full load) 10 ma 1 3 mv 1.2 ma 0.2 ma 50 mv (30 mv @ full load) 2 ma 5 ma 130 W 20 mv 4 mv 1.0 ma 0.2 ma (80 mv @ full load) 2 ma 5 ma Analog Programming Note: for SM300-20 / SM600-10 see ISO AMP Programming inputs in put range ac cu racy off set temp. coeff. off set in put im ped ance Monitoring outputs out put range ac cu racy off set temp. coeff. off set out put im ped ance ISO AMP Pro gram ming op tional for low volt. units up to120v (P154), stan dard on SM300-20 and SM600-10. ± 0.2% - 0.1... +1.3 mv (on 5V) 10 µv / C > 1 MOhm ± 0.2% - 1... 0 mv (on 5V) 3 µv / C 2 Ohm / max. 4 ma ± 0.5% 0... +2. (on 5V) 50 µv / C > 1 MOhm ± 0.5% - 1.1... 0 mv (on 5V) 60 µv / C 2 Ohm / max. 4 ma Iso lated an a log pro gram ming, range / 200 kohm or 0-10 V / 400 kohm. See datasheet ISO AMP on www.deltapowersupplies.com for ac cu racy, off set etc. Ref er ence volt age on prog. con nec tor V ref TC +12 V out put V o on prog. Con nec tor I max R o 5.114 ± 1 (Ro = 2 Ohm, max. 4 ma) 20 ppm / C 12 V ± 0.2 V 0.2 A 3 Ohm Page 1-2 SPECIFICATIONS July 2003, rev. March 2012
SM6000 DELTA ELEKTRONIKA BV Status outputs - sta tus LIM - sta tus OT - sta tus PSOL - sta tus ACF - sta tus DCF - sta tus Relay Outputs ACF DCF - op er a tion or limit Over Tem per a ture Power Sink Over load AC - Fail DC - Fail 1 ) AC - Fail DC - Fail both NO and NC con tact 1 ) both NO and NC con tact 1 ) out put ± 5% be yond set point Remote ShutDown with + 5V, 1 ma or re lay con tact In ter lock con tact at rear panel, see photo of rear panel on page 1-6 In di ca tors (front panel) AC-Fail, DC-Fail, Over Tem per a ture, Power Sink Over load, Re mote-shutdown, Re mote-, Re mote-, Out put On, -limit, -limit, - and - mode Controls (front panel) Mains on/off, -and -potmeter, - and -limit-potmeter, Dis play-set tings but ton, Dis - play-lim its but ton, Re mote/lo cal, Out put On/Off, Front panel Lock Programming speed Stan dard Ver sion (re sis tive load) Rise time (10-90%) Fall time (90-10%) Programming speed High Speed Ver sion (re sis tive load) Rise time (10-90%) SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 0 15 V 3.3 ms 1.3 ms 15 0 V 3.5 ms 34 ms SM 15-400 Op tion P166 0 15 V 0.40 ms 0.38 ms 0 30 V 6.4 ms 2.5 ms 30 0 V 6.7 ms 67 ms SM 30-200 Op tion P167 0 30 V 0.41 ms 0.38 ms 0 45 V 2.7 ms 1.1 ms 45 0 V 2.9 ms 32 ms SM 45-140 Op tion P168 0 45 V 0.53 ms 0.16 ms 0 60 V 5.4 ms 2.2 ms 60 0 V 5.8 ms 59 ms SM 60-100 Op tion P169 0 60 V 0.44 ms 0.41 ms 0 70 V 6.8 ms 2.8 ms 70 0 V 7.7 ms 77 ms SM 70-90 Op tion P170 0 70 V 0.62 ms 0.40 ms 0 120 V 5.1 ms 1.9 ms 120 0 V 4.9 ms 52 ms SM 120-50 Op tion P171 0 120 V 0.57 ms 0.19 ms 0 300 V 8.5 ms 3.2 ms 300 0 V 8.3 ms 83 ms SM 300-20 Op tion P172 0 300 V 1.1 ms 0.44 ms 0 12 ms 4.8 ms 600 0 V 12 ms 120 ms SM 600-10 Op tion P270 0 1.9 ms 0.80 ms Fall time (90-10%) 15 0 V 0.39 ms 1.5 ms 30 0 V 0.41 ms 3.6 ms 45 0 V 0.26 ms 10 ms 60 0 V 0.57 ms 5.6 ms 70 0 V 0.50 ms 6.2 ms 120 0 V 0.38 ms 4.2 ms 300 0 V 1.0 ms 10 ms 600 0 V 2.2 ms 20 ms Rip ple @ full load typ i cal (rms / pp) 6/20mV 28/80mV 34/80mV 34/90mV 38/100mV 30/120mV 48/150mV 35/220mV Output Capacitance (typ i cal) 1200 µf 800 µf 520 µf 330 µf 290 µf 73 µf 32 µf 19 µf Re cov ery time re cov ery within di/dt of load step out put volt age time, @ 50-100% load step max. de vi a tion Output impedance, 0-1 khz, 1-100 khz Pul sat ing load max. tol er a ble AC com po nent of load cur rent f > 1 khz f < 1 khz SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 60 mv 5 A/µs 13 V 120 µs 320 mv < 0.5 mω < 2.3 mω 30 Arms 400 Apeak 50 mv 2.5 A/µs 25 V 260 mv < 1.2 mω < 5 mω 35 Arms 200 Apeak 1.8 A/µs 40 V 380 mv < 1.7 mω < 10 mω 20 Arms 140 Apeak 1.3 A/µs 55 V 250 mv < 1.5 mω < 12 mω 20 Arms 100 Apeak 1.7 A/µs 65 V 280 mv < 1.8 mω < 12 mω 20 Arms 90 Apeak 0.5 V 1 A/µs 110 V 1 V < 11 mω < 90 mω rms 50 Apeak 1 V 0.25 A/µs 280 V 1.8 V < 34 mω < 330 mω 5 Arms 20 Apeak 1 V 0.125 A/µs 560 V 1.8 V < 70 mω < 700 mω 2.5 Arms peak In su la tion in put / out put creepage / clear ance in put / case out put / case Safety ctuvus / EN 60950 / EN 61010 3750 Vrms (1 min.) 8 mm 2500 Vrms DC (1200 V DC for SM300-20 and SM600-10) July 2003, rev. March 2012 SPECIFICATIONS Page 1-3
DELTA ELEKTRONIKA BV SM6000 EMC Power Sup ply Stan dard Ge neric Emis sion Ge neric Im mu nity EN 61204-3, Emis sion: res i den tial, light in dus trial en vi ron ment (CISPR22-Class B) Im mu nity: in dus trial en vi ron ment EN 61000-6-3, res i den tial, light in dus trial en vi ron ment (EN 55022 B) EN 61000-6-2, in dus trial en vi ron ment Operating Temperature at full load 20 to + 50 C de rate out put to 75% at 60 C Humidity max. 95% RH, non con dens ing, up to 40 C max. 75% RH, non con dens ing, up to 50 C Storage temperature 40 to + 85 C Thermal protection Out put shuts down in case of in suf fi cient cool ing MTBF 500 000 hrs Hold-Up time V out = 100%, I out = 100% V out = 85%, I out = 100% V out = 100%, I out = 50% @ 400 V AC in put SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 33 ms 28 ms 27 ms 24 ms 28 ms Turn on de lay af ter mains switch on 200 ms 13 ms 30 ms Inrush current 20 A (elec tronic limit) Phase loss 13 ms 24 ms 32 ms Out put shuts down in case of phase loss 12 ms 24 ms 28 ms 27 ms Se ries op er a tion max. to tal volt age Mas ter / Slave op er a tion Par al lel op er a tion Nor mal Mas ter / Slave op er a tion no limit max. 3 units Re mote sens ing max. volt age drop per load lead 2 V Limits Voltage ad just range Cur rent ad just range Front panel /-con trols res o lu tion knob op er a tion screw driver ad just ment an a log po ten ti om eters 1) 10 turns (0.03%) stan dard op tional (P001) 0-102% 0-102% 1200 V 1200V dig i tal encoders 10 or 64 turns 2) stan dard no Lock func tion for /-set tings Selectable Start-up at 0V / 0A or at last set tings Me ters scale volt age scale cur rent ac cu racy read out put read limit set ting (d = digit) 0-15.00 V 0-400 A no no 1) op tional with dig i tal encoders (P220) : spec i fi ca tions for con trols are sim i lar to SM300-20 and SM600-10. 0-30.0 V 0-200 A 0-45.0 V 0-140.0 A 0-60.0 V 0-100.0 A 0-70.0 V 0-90.0 A 0-120.0 V 0-50.0 A 2) vari able pitch de pend ing on op er a tion speed 0-300 V 0-20.0 A 0-0 - 10.0 A Mounting Stack ing of units al lowed, air flow is from left to right. Input Terminals Screw Ter mi nals for ca ble 2.5-4 mm 2, 3 phase + earth (no neu tral re quired) Output Terminals M12 bolts M10 bolts M10 bolts M10 bolts M10 bolts M8 bolts M8 bolts M8 bolts Programming connector 15 pole D-con nec tor at rear panel (FE MALE) Cooling au dio noise level air flow Low noise blower, fan speed adapts to tem per a ture of in ter nal heatsink. ca. 56 dba at full load, 25 C am bi ent tem per a ture, 1 m dis tance ca. 62 dba at full load, 50 C am bi ent tem per a ture, 1 m dis tance From left to right En clo sure de gree of pro tec tion IP20 Di men sions be hind front panel: h x w x d front panel: h x w Weight 177 x 443 x 500 mm 177 x 483 mm (19", 4 U) 27 kg Page 1-4 SPECIFICATIONS July 2003, rev. March 2012
SM6000 DELTA ELEKTRONIKA BV Typical Applications Solar inverter testing, PV-Simulation Controlled Battery (dis)charging Plasma cham bers La sers Hy brid Car test sys tems Driv ing PWM-Con trolled DC mo tors ATE in in dus trial pro duc tion lines Ac cu rate cur rent sources Au to mo tive bat tery sim u la tions Aero space and mil i tary equip ment Available Options In creased Out put Power The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be increased by about 10%. High Speed Programming A 10 to 20 times higher programming speed (down to 0.4 ms rise time at full load) and lower output capacitance 1). Excellent for laser applications, test systems or as current source with low parallel capacitance as used in plasma chambers. Two-Quad rant Out put: Power sink Two quadrant operations maintains the output voltage constant regardless the output power is positive or negative 1). Ideal for PWM-speed controlled DC-motors and ATE systems. Order Code - P069 Order Codes: SM 15-400 P166 - SM 30-200 P167 SM 45-140 P168 - SM 60-100 P169 SM 70-90 P170 - SM 120-25 P171 SM 300-20 P172 - SM 600-10 P270 Order Codes: SM 15-400 P230 - SM 30-200 P231 SM 45-140 P232 - SM 60-100 P233 SM 70-90 P234 Order Code - P157 Sequencer Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. Order Code - P089 High Volt age Iso la tion A higher output isolation allows series operation up to 1200V. Is standard on SM300-20 and SM600-10. Order Code - P165 High In put Volt age Higher input voltages possible for operations at line voltages of 440 V AC and 480 V AC (for USA). Soft ware con trol and Interfaces Factory installed programming interfaces 2) : ISO AMP Card - isolated analog - P154 3) RS232 controller - P155 IEEE488 controller - P156 Ethernet contr. (incl. sequencer) - P157 PROFIBUS controller - P277 CANBUS controller - P278 Dig i tal Volt age and Cur rent Set ting Reliable, longlife digital encoders can be implemented at the front panel. Includes total front panel lock (also for /-knobs) and a coarse or fine pitch adjustment depending on the turning speed. Is standard on SM300-20 and SM600-10. Order Code - P220 Se cured Volt age and Cur rent Set ting For a maximum security, the / settings can be adjusted with a screwdriver only and are protected with a plastic cap from accidental adjusting. Is not possible on SM300-20 and SM600-10 or in combination with P220. Order Code - P001 Notes: 1. Down load spe cial datasheets about High Speed Progr., Power Sink and Bat tery Charg ing from www.deltapowersupplies.com. 2. There is only room for one of the in ter faces in a unit (P154, P155, P156, P157, P277 or P278). 3. SM300-20 and SM 600-10 stan dard equipped with ISO AMP, this can be re placed by P155, P156, P157, P277 or P278. July 2003, rev. March 2012 SPECIFICATIONS Page 1-5
DELTA ELEKTRONIKA BV SM6000 = Con stant Volt age = Con stant Cur rent Specifications measured at t amb = 25 ± 5 C and Vin = 400 V AC, 50 Hz, 3 phase, un less oth er wise noted. The information in this document is sub ject to change with out no tice Con nec tions an a log pro gram ming con nec tor InterLock Status Relay Mas ter/ Slave an a log (standard) Programming Connectors RS232, CANopen, PROFIBUS, Ethernet user I/O (all optional) Ethernet, IEEE488, isolated analog (all optional) NO Line Cord supplied Sense Block Output Terminals Input Connector Safety Cov ers sup plied for in- and out put (not shown) Feet are not mounted but included in packing Note: SM300-20 and SM 600-10 stan dard with iso lated an a log pro gram ming via ISO AMP on CON H (CON E is not avail able). Your distributor: Page 1-6 SPECIFICATIONS July 2003, rev. March 2012