Leica Digicat i-series Safe and fast location of underground services

Similar documents
Leica Digisystem Safe and fast location of underground services

Leica Digisystem i-series Safe and fast location of underground utilities

Leica DIGISYSTEM TM Safe and fast location of underground services

EZi & ULTRA SYSTEMS. Cable Tracing and Locating EZi & ULTRA Sytems

Ca b l e Tr a c i n g a n d L o c a t i n g EZi & ULTRA Sytems

UAT-600 Series. amprobe.com

leica-geosystems.com Leica DD SMART utility locator solution Work safer, work smarter, work simpler

A higher performance product designed for safer excavating.

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

The new CXL2 and DXL2 Cable Avoidance Tools and SGA2 and SGV2 Signal Generators from C.Scope have been designed to set a new benchmark in excavating

UTILITY LOCATING EQUIPMENT

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Leica Rugby 600 Series Your reliable partner on site

Leica Rugby 600 Series Your reliable partner on site

Cable avoidance reaches a new level

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

Leica Rugby 600 Series Your reliable team player on site

Obsolete Document. Dynatel

AT-5000 Professional Underground Cable / Pipe Locator System

Leica Sprinter Go ahead... Push the button

Locator Accessories INSTRUCTION MANUAL

TW-82P DIGITAL LINE TRACER WITH PASSIVE POWER DETECTION. Operating Manual

vscan Data Sheet V1.0

Pipeline Current Mapper

SuperCAT 4+ Utility-specific range for finding CPS protected pipes, sondes, telecom and power cables

High Performance, Application Specific Cable Avoidance

pipeline integrity PCM + Pipeline Current Mapper

Utility cable and pipe locator

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

Version 1.0 English. EziSYSTEM User Manual

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

TW-82 TW-82 ACCESSORIES. Operating Manual Revision Level 1 DIGITAL LINE TRACER

TW-82. Operating Manual DIGITAL LINE TRACER. Revision Level 1

Cable avoidance reaches a new level

cable and pipe locators RD Utility cable and pipe locator

F I S H E R R E S E A R C H L A B O R A T O R Y

TRIAD SERIES 2310 SC

General Warnings Non-Metallic Pipe Tracing Features Depth Measurement Locator Operating Modes Signal Current Measurement Function Checks

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

SeekTech SR-60 SeekTech SR-20 NaviTrack Scout

TW-82 DIGITAL LINE TRACER. Operating Manual

Dynatel 2250E/2273E Advanced Cable and Fault Locator

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Products. Locating DAMAGE PREVENTION

Loki Pipe & Cable Locators

Universal precision cable and pipe locator

Table of Contents - 2 -

C.A.T and Genny User Guide. Revision

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Instruction Manual CXL Locator DXL Locator MXL Locator SGA Signal Generator SGV Signal Generator MXT Transmitter

AT-7000 Advanced Wire Tracer

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

Insulation Testers and Earth Ground Testers

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT

Radiodetection Pipeline Products

8873 v3 Pathfinder Locator User Manual

MIT480/2 Insulation testers

RD8100 OPTIMUM PRECISION FOR DAMAGE PREVENTION

Mag 3/6 System. Manual.

Leica SmartStation Total Station with integrated GNSS

MIT400/2 CAT IV Insulation testers

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

STAFF User Manual. Manual Part #

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

PV210. Why buy the PV210?

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Leica SmartStation Total Station with integrated GPS

PIPELINE DEFECT MAPPER

vloc Series 2 Smaller and lighter Over four times battery life Define, set and lock available features Customizable startup screen and much more...

MIT400/2 CAT IV Insulation testers

QLD/NT NSW WA

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

AT-4000 Advanced Tracer User s Manual

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

DITCH WITCH LOCATORS

Wireless Pressure Station with Backlight

Fully automated three phase 250V Transformer Turns Ratio Meter

Easy to use, single frequency. pipe and cable locator

Model UT233 OPERATING MANUAL

Pipe & cable locator for avoidance & tracing applications. The ideal choice for the novice through to the skilled technician

Leica GRX1200+ Series High Performance GNSS Reference Receivers

PRECISION PIPE AND CABLE LOCATION. Instruction Manual Function Checker

spy pig Tracking systems

Utility cable and pipe locator

Leica GRX1200 Series High Performance GNSS Reference Receivers

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User Manual 8880 Series Fault Finding & Locating Kit

MIT400 CAT IV Industrial Insulation Testers

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

MIT400 CAT IV Industrial Insulation Testers

S u b s i t e L o c at o r s

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

Transcription:

Leica Digicat i-series Safe and fast location of underground services

Leica Digicat i-series Making Cable Avoidance Easier and Safer Every year site workers are injured due to inadvertently striking buried utilities such as electricity cables or gas pipelines. Obtaining accurate information about the location of buried utilities has never been more essential to protect employees and equipment during any excavation project. Local legislation prescribes the use of a locating device before any kind of excavation takes place. It makes perfect sense to search for, trace and mark all services before work commences. With all our Digicat locators, users can detect buried utilities with ease. The range has been specifically designed to reduce human error and to increase site safety with its wealth of intelligent and unique features. Typical users of the Digicat: Excavation contractors Utility installation & repair contractors General contractors Builders Gas & Electricity companies Cable TV companies Pipe laying contractors The Digicat is comprised of: Digicat 500i/550i or 600i/650i Service Locator Digitex 100t Signal Transmitter Digitrace Service Tracer and additional accessories The Digicat range makes locating underground cables and pipes a simple and efficient task, increasing your onsite safety and ultimately saving you time and money. How does the Digicat locate? The Digicat range locates buried conductive services by receiving electromagnetic signals which radiate from them. The Digicat s intelligent software interprets the signal data and provides the operator with an audible and visual response to the location and direction of buried utilities. The operator can mark the ground or use a GIS mapping device* to note the location, providing the excavation team with clear indications of utility positions. * on Digicat models with Bluetooth functionality

Leica Digicat Benefits State-of-the-art Digital Signal Processing (DSP) technology Automatic controls making the Digicat easy-to-use, requiring minimal user experience Power Mode start-up ensuring the most potentially dangerous current carrying services are detected first Hazard Zone feature indicating shallow buried service in power, 8 and 33 khz modes, (within approximately 30 cm) alerting increased risk Built-in test function for testing hardware and software LCD screen with built-in light sensor, automatically enabling the backlight in dark conditions Robust, lightweight design, specifically engineered for tough site conditions Service Due Indicator supporting planned maintenance schedules or quality systems by displaying a wrench icon after 12 months The Digicat i-series locators have multiple modes of operation allowing users to have maximum control at their fingertips. Auto Auto Mode Automatically locates power or radio signals, helping to confirm the presence of services upon initial site occupation making cable detection easier and safer. Power Mode (Default mode) Locates power signals radiated by energised cables which pose the most significant risk to excavation teams. Radio Mode Traces signals originating from distant radio transmitters. These signals penetrate the ground and are reradiated by buried conductive services. 8 khz 33 khz Transmitter Modes (8 & 33 khz) Locates a specific signal applied by the Digitex dual frequency signal generator to a metallic underground conductor.

Leica Digicat i-series High level intelligence High Contrast LCD Screen On/Off Trigger Battery Compartment Light Sensor (Automatically enables backlight) Rugged Casing Signal Strength Indicator Service Depth Indication Detection Mode Selection Depth Button and Menu Access Replaceable Foot Depth Indication The Digicat 550i & 650i feature utility depth indication, when used in conjunction with the Digitex 100t signal generator or Digimouse in 8 or 33 khz modes. With a single press of the button operators are provided with the approximate depth of the buried utility. Hazard Zone Buried utilities close to the surface pose a significant safety risk to site works. The new Hazard Zone function provides an additional warning to the close proximity of buried services, alerting users to the immediate danger. Enhanced Sonde Detection The Digicat i-series feature numeric signal strength readout, specifically designed for easy sonde location. The highest number displayed indicates the exact position of the Digimouse beneath the ground. Service Due Indicator Supporting customer planned maintenance schedules or quality systems, by displaying a wrench icon after 12 months. Pinpoint Assist Maintains the highest peak reading obtained on the signal strength indicator for a period of time, allowing the operator to swiftly and accurately pinpoint the service position. Additional Features (Digicat 600 i-series only) Data Logging The Digicat 600 i-series records and stores information while in use. Information is recorded every second after completion of the initial start-up routine. These records are stored in the locators memory and can be retrieved and transferred via Bluetooth to a PC or other electronic device for analysis. Storage time is approximately 80 hours use. Logicat Software* Allows you to upload the stored records to view the locators use, simply upload all records or search by date. Bluetooth Connectivity The Digicat 600 i-series has the added benefit of Bluetooth wireless connectivity. It allows the Digicat to integrate seamlessly with mobile mapping technology to log survey data, in addition to enabling wireless Bluetooth data transfer. *Digicat 600 i-series features full Logicat software compatibility, see page 6.

Leica Digitex 100t Signal Transmitter Quick Reference Guide Accessory Storage Compartment Battery Compartment User Controls Leica Digitex 100t delivers significantly higher power than previous models. This improved performance will allow users to: Trace services over a greater distance Improve service detection in areas of high signal interference Improve depth estimation when using a depth locator Direct Connection Connect the Digitex 100t to a conductive service such as a valve, stop tap or other access point. Signal Clamp Connection A signal clamp is used to apply the Digitex 100t signal to a pipe or live electricity cable. Supply is not interrupted by the signal and the operator is not exposed to any live services. Induction The Digitex 100t induces a tracing signal into the buried pipe or cable. This is a quick and convenient method when direct connection or signal clamping is not possible. Features Digitex 100t (Art. No. 795946) Operating transmission frequencies 8.192kHz 32.768kHz Mixed 8/33 connection mode only Output power 4 levels Induction (Max) Up to 1W max Direct connection (100 Ohms) Up to 1W max when connected to a buried service with an impedance of 100 Ohms Battery type 4 x D alkaline (IEC LR20), supplied Battery life (Typical use at 20C) 30hrs intermittent use Weight 2.4kg/5.3lbs including batteries Dimensions 7 in. (H) x 10 in. (D) x 11 in. (W) IP rating (Case lid closed) IP65 IP rating (Case lid open) IP54

Logicat Software Simply upload stored records Logicat software allows you to upload stored records from the Digicat 600i and 650i to view the locators use, simply upload all records or search by date. Upload information includes: Time and Date Identifies when and at what time ground surveys were conducted. Usage Duration Determines how long survey teams searched for buried services and reveals actual product utilisation. User Identification Forces users to become accountable for their actions and identifies those who need additional product training. Detection Mode Allows managers to judge the quality and thoroughness of work. As more comprehensive ground surveys are conducted the locator records the mode of operation including the use of a signal generator. Service Detection Discovers quickly if any buried services were detected during surveys and even determines the signal strength shown on the locator. Product Fleet Management Displays and monitors the service and calibration dates of your locator fleet, ensuring they are kept in perfect working order and not being used when calibration is due. Diagnostic Check Displays locators which have failed the EST (Extended Self Test) and removes them from the active fleet for immediate repair. This reduces the possibility of defective equipment being used on site. Management Reports Produces basic statistical reports from the logged data, allowing users to see how products are utilised and how ground survey teams are using them on-site. Logicat Software Art. No. 795945 Digicat Accessories Signal Clamp For use with the Digitex 100t signal transmitter, enabling connection to cylindrical metallic services (e.g. pipes, insulated electricity cables). Property Connection Set For use with the Digitex 100t signal transmitter. Connection of a tracing signal to any internal power distribution system outlet. Digimouse (8 khz & 33 khz) Compact dual frequency signal transmitter used to trace drains, sewers and other non conductive services. Digimouse can be attached to a range of equipment including drain rods, boring tools and inspection cameras.

Leica Digicat i-series Excellent customer support, service and training Technical Support Users of the Digicat have easy access to technical support, should it be required. Front line technical support for all tools is provided from experienced professionals at your local dealer or your nearest Leica Geosystems representative. Service & Repair Leica Geosystems strongly recommend that the tools are regularly serviced and calibrated every 12 months in an authorised Leica Geosystems service centre or dealer workshop. The repair costs and turnaround times for Digicat products are highly competitive. Training Operator training for the Digicat is available from our own qualified trainers, or via our approved dealers. Features Digicat 500i (Art. No. 50Htz 780225/60Htz 780226) Digicat 550i (Art. No. 50Htz 780231/60Htz 780232) Digicat 600i (Art. No. 50Htz 795939/60Htz 795940) Digicat 650i (Art. No. 50Htz 795941/60Htz 795944) Frequency / Mode Power mode 50 Hz or 60 Hz, Power mode 50 Hz or 60 Hz, Power mode 50 Hz or 60 Hz, Power mode 50 Hz or 60 Hz, Radio mode 15 khz to 60 khz Radio mode 15 khz to 60 khz Radio mode 15 khz to 60 khz Radio mode 15 khz to 60 khz Generator mode 8 khz and 33 khz, Generator mode 8 khz and 33 khz, Generator mode 8 khz and 33 khz, Generator mode 8 khz and 33 khz, Auto mode = Power + Radio mode Auto mode = Power + Radio mode Auto mode = Power + Radio mode Auto mode = Power + Radio mode Depth detection (typical) Power to 3m (10 ft), Radio to 2m (6.5 ft), Power to 3m (10 ft), Radio to 2m (6.5 ft), Power to 3m (10 ft), Radio to 2m (6.5 ft), Power to 3m (10 ft), Radio to 2m (6.5 ft), Transmitter mode to 3m (10 ft) Transmitter mode to 3m (10 ft) Transmitter mode to 3m (10 ft) Transmitter mode to 3m (10 ft) Depth estimation 10% of depth in line or sonde 10% of depth in line or sonde 0.3m (1 ft) to 3m (10 ft) depth range 0.3m (1 ft) to 3m (10 ft) depth range Protection Conforms to IP54 Conforms to IP54 Conforms to IP54 Conforms to IP54 Bluetooth Available as standard Available as standard Batteries 6 x AA alkaline (IEC LR6 supplied) 6 x AA alkaline (IEC LR6 supplied) 6 x AA alkaline (IEC LR6 supplied) 6 x AA alkaline (IEC LR6 supplied) Battery life 40 hours intermittent use (at 20 C) 40 hours intermittent use (at 20 C) 40 hours intermittent use (at 20 C) 40 hours intermittent use (at 20 C) Weight 2.7 kg (6 lbs) including batteries 2.7 kg (6 lbs) including batteries 2.7 kg (6 lbs) including batteries 2.7 kg (6 lbs) including batteries Compatibility CSV file compatibility program CSV file compatibility program Memory size 32Mb memory 32Mb memory Capability 80hrs of data 80hrs of data Digicat Accessories The Digitrace enables a complete length of non-metallic drains, duct or pipes to be traced when used in conjunction with the Digicat and the Digitex 100t or other signal transmitters. The Digitrace coiled fibre-glass rod, which protects the central copper tracing conductor, is available in lengths of 30 metres, 50 metres or 80 metres. The fibre-glass rod is inserted and pushed along in the service under investigation. The Digitex 100t is connected, and the tracing signal is located on the surface by the Digicat. Fibre-glass rod Sonde Features Digitrace 30/50/80 (30/50/80 metre coil of copper conductor sheathed by fibre glass) Protection Conforms to IP57 Included Accessories Connections to Digitex 100t cable set Weight 3.0 kg (6.5 lbs)/3.25 kg (7 lbs)/3.5 kg (7.5 lbs)

Whenever you need to locate underground services, the Leica Digicat is the right solution. The system ensures fast and accurate location of buried cables and pipes and it increases your onsite safety. The Digicat is designed on a safety-first philosophy, so we remove the ability for the user to «tune out» signals or to accidentally search in the wrong mode. The Digicat tools are rugged and efficient, meeting all the needs of your tracing operations. When it has to be right. Illustrations, descriptions and technical data are not binding. All rights reserved. Printed in Switzerland Copyright Leica Geosystems AG, Heerbrugg, Switzerland, 2012. 781158enUS IV.12 galledia Total Quality Management our commitment to total customer satisfaction. Ask your local Leica Geosystems dealer for more information about our TQM program. The Bluetooth word mark and logos are owned by Bluetooth SIG, Inc. and any use of such marks by Leica Geosystems AG is under licence. Other trademarks and trade names are those of their respective owners. Leica Sprinter Quick, easy and efficient digital levelling Leica NA700 Series Jobsite Tough, Clearly Precise Leica Builder Not just for foremen Leica Rugby 260SG, 270SG, 280DG Keeps you working Leica Piper 100/200 The world s most versatile pipe laser Leica Geosystems AG Heerbrugg, Switzerland www.leica.geosystems.com Leica Geosystems AG Heerbrugg, Switzerland www.leica-geosystems.com