Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 17-19, 2005 (pp )

Similar documents
Transformer Protection

A NEW DIFFERENTIAL PROTECTION ALGORITHM BASED ON RISING RATE VARIATION OF SECOND HARMONIC CURRENT *

POWER TRANSFORMER PROTECTION USING ANN, FUZZY SYSTEM AND CLARKE S TRANSFORM

Feature Extraction of Magnetizing Inrush Currents in Transformers by Discrete Wavelet Transform

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

Analysis of Modern Digital Differential Protection for Power Transformer

Problems connected with Commissioning of Power Transformers

ANALITICAL ANALYSIS OF TRANSFORMER INRUSH CURRENT AND SOME NEW TECHNIQUES FOR ITS REDDUCTION

Transformer Protection

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

MATHEMATICAL MODELING OF POWER TRANSFORMERS

Demagnetization of Power Transformers Following a DC Resistance Testing

Tab 2 Voltage Stresses Switching Transients

Keywords: Transformer, differential protection, fuzzy rules, inrush current. 1. Conventional Protection Scheme For Power Transformer

CHAPTER 3 REVIEW OF POWER TRANSFORMER PROTECTION SCHEMES

Improved power transformer protection using numerical relays

STRAY FLUX AND ITS INFLUENCE ON PROTECTION RELAYS

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Improving Transformer Protection

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

REDUCTION OF TRANSFORMER INRUSH CURRENT BY CONTROLLED SWITCHING METHOD. Trivandrum

Transformer Protection Principles

Preface...x Chapter 1 Electrical Fundamentals

Improved differential relay for bus bar protection scheme with saturated current transformers based on second order harmonics

IV/IV B.Tech (Regular) DEGREE EXAMINATION. Electrical &Electronics Engineering

Busbars and lines are important elements

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

International Journal of Advance Engineering and Research Development ANALYSIS OF INTERNAL AND EXTERNAL FAULT FOR STAR DELTA TRANSFORMER USING PSCAD

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

A Special Ferro-resonance Phenomena on 3-phase 66kV VT-generation of 20Hz zero sequence continuous voltage

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

FERRORESONANCE SIMULATION STUDIES USING EMTP

Negative-Sequence Based Scheme For Fault Protection in Twin Power Transformer

Unit Protection Differential Relays

Decriminition between Magnetising Inrush from Interturn Fault Current in Transformer: Hilbert Transform Approach

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

TECHNICAL BULLETIN 004a Ferroresonance

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Power System Protection. Dr. Lionel R. Orama Exclusa, PE Week 3

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Ferroresonance Experience in UK: Simulations and Measurements

The measurement of winding resistance is useful in detecting a number of types of fault in a transformer. Malfunctioning tap changer mechanisms

Single-Phase Transformation Review

Reducing the magnetizing inrush current by means of controlled energization and de-energization of large power transformers

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Capacitive Voltage Substations Ferroresonance Prevention Using Power Electronic Devices

2. Current interruption transients

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

A Novel Technique for Power Transformer Protection based on Combined Wavelet Transformer and Neural Network

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Design of Differential Protection Scheme Using Rogowski Coil

Protective Relaying of Power Systems Using Mathematical Morphology

The power transformer

ELECTRICAL POWER ENGINEERING

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Transformer Fault Categories

Protection of Electrical Networks. Christophe Prévé

Harmonic Distortion Impact On Electro-Mechanical And Digital Protection Relays

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Power Quality Analysis in Power System with Non Linear Load

Analyzing the Impact of Shunt Reactor Switching Operations Based on DFR Monitoring System

Back to the Basics Current Transformer (CT) Testing

Discrimination of Fault from Non-Fault Event in Transformer Using Concept of Symmetrical Component

Electrical Protection System Design and Operation

Switching and Fault Transient Analysis of 765 kv Transmission Systems

Relay Protection of EHV Shunt Reactors Based on the Traveling Wave Principle

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Line protection with transformer in the protection zone

Generator Protection GENERATOR CONTROL AND PROTECTION

Innovative Science and Technology Publications

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Turn-to-Turn Fault Detection in Transformers Using Negative Sequence Currents

XD1-T - Transformer differential protection relay

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

Single-Core Symmetrical Phase Shifting Transformer Protection Using Multi-Resolution Analysis

ROGOWSKI coil current sensors are transformers that

Basic Principles and Operation of Transformer

Importance of Transformer Demagnetization

Impact of transient saturation of Current Transformer during cyclic operations Analysis and Diagnosis

Ferroresonance Conditions Associated With a 13 kv Voltage Regulator During Back-feed Conditions

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

Insulation Level and Test Technology of. 1000kV Power Transformer

CHAPTER 4. Distribution Transformers

Application of Discrete S-Transform for Differential Protection of Power Transformers

Improving Current and Voltage Transformers Accuracy Using Artificial Neural Network

UProtection Requirements. Ufor a Large scale Wind Park. Shyam Musunuri Siemens Energy

Three-Phase/Six-Phase Conversion Autotransformers

Differential Protection with REF 542plus Feeder Terminal

Distance Relay Response to Transformer Energization: Problems and Solutions

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Transformer protection IED RET 670

Earth Fault Protection

Application of Wavelet Transform in Power System Analysis and Protection

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

Simultaneous AC-DC Transmission Scheme Under Unbalanced Load Condition

Current Transformer Performance study Using Software Tools.

Transcription:

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 7-9, 5 (pp567-57) Power differential relay for three phase transformer B.BAHMANI Marvdasht Islamic Azad University MARVDASHT,IRAN M.NAFAR Marvdasht Islamic Azad University MARVDASHT,IRAN A.M.RANJBAR Niroo Research Institute TEHRAN, IRAN Abstract : To avoid the needless trip by magnetizing inrush current, the second harmonic component is commonly used for blocking differential relay in power transformers. However, the second harmonic component in fault current is increased in long lines and underground cable because increased together with the capacitance in power system. This paper describes a method to discriminate internal fault from inrush current by the sum of active power flowing into the transformer from each terminal. The average power is almost negligible for energizing, but an internal fault consumes large power. Key-Word: transformer, protection, fault, active power relays, EMTP,TACS. INTRODUCTION Differential relays are commonly used for the transformer protection. They detect differential current or the sum of current flowing into the transformer. To avoid the needless trip by magnetizing inrush current, the second harmonic component is commonly used for blocking the relay operation. this method was invented more than 6 years ago [-]. Due to an increase in demand for electricity, power transmission systems are steadily becoming larger both in capacity and voltage levels and transmission lines, which are normally composed of multi-conductors, are becoming longer. A direct consequence of the latter is an increase in line capacitance to ground and a widespread usage of underground cable sections also contributes to an increase in the line capacitance. This inevitably results in an increase in the level of lower harmonics( in particular the second harmonic) present in the transformer windings due to a fault, arising as a result of the interaction of the line inductance with capacitance; in certain cases its magnitude can be close to or greater than that present in the magnetizing inrush current. The problem is accentuated by the employment of special ironcored materials in modern large transformers; their magnetizing characteristics have shown that the increased residual flux can lead to transformer saturation on energizing and a reduction in the second harmonic component present in the inrush current, consequently. Conventional protection techniques will thus have difficulty in distinguishing between an internal fault and an inrush transient. Alternative, improved protection techniques have thus to be found The power based differential protection (PDP) discussed here is designed for three phase transformers. The algorithm calculates and works with the products of current and voltage and calculates the active power. A winding fault during an inrush current is a very common fault. therefore it should be recognized fast. such faults can be analyzed much faster and more sensible with the new power based differential protection(pdp) relay than with a conventional current differential protection(cdp) relay. As for 5KV or less transformer, ideas focusing on the inductance during iron saturation [3]. or on the flux calculated from the differential current and integral of voltage have been proposed [4]. These years new methods using artificial neural networks and fuzzy logic are also proposed [5]. However, no method seems to be practical level yet.

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 7-9, 5 (pp567-57) This paper propose a new method focusing on the consumed energy that shows the heat from arc discharge during the insulation fault in proportion to the damage in transformers. At first, the basic theory and algorithm are explained, afterward simulation results for inrush current and fault condition in transformer is presented by using EMTP software. At last, by simulating the power differential relay the operation of this relay is shown in fault condition at power transformer. Theory of power differential method. Physical phenomena and theory In the normal operation state of higher voltage power transformer, the sum of power flowing into the transformer is very little, because the copper loss and core loss are less than % of the transformer capacity. When we consider instantaneous power, it flows in and out according to the magnetic energy stored in windings. However, the average power or active power is almost negligible. Just after the energizing, large magnetizing current flows during the iron saturation. The current depends on the remnant flux in the iron core as well as the energizing phase in voltage. Instantaneous power is also large, but the average power is still small though iron and copper loss as well as eddy current loss may be increased a little bit. on the other hand, when a transformer has an insulation failure, large power is consumed by arcing discharge. This power or heat makes gas from the insulation oil. If the protection relay cannot operate at the enough speed, the pressure in tank is increased and the oil is discharged or the tank is exploded. In this process, the average of instantaneous power is large.therefore, if we set a threshold of average power flowing into the transformer, faults can be detected. It is better way to watch the power calculated from the average power minus copper loss when large fault current flows through transformers when a substation bus or line has a fault. The power can be easily calculated from the current and voltage at each terminal of transformer using today s microprocessor based digital relay [6].. Discrimination algorithm Though the method is effective for every multiwinding transformer, in order to simplify the explanation, two-winding transformer is adopted here. W( t) = T T t-t ( VI VI ( R + RG ) I ( R + R G ) I ) dt where V, I, V, I are instantaneous voltage and current at the primary and secondary winding terminal. R, RG, R, RG are d.c resistance and neutral resistance at the primary and secondary winding terminal. W (t) means the average power flowing into transformer during one period T(ms in 5Hz system).when large inrush current starts to flow, W (t) is increased to serve magnetic energy stored in windings. However, W (t) should be almost equal to core loss plus stray losses from the second period after the energizing. On the other hand, when a transformer has an internal fault, large amount of power is consumed proportional to the fault degree or arc discharge distance. W (t) is increased according to the fault current multiplied by arc voltage. By watching W (t), which is directly related to damage received by the transformer, internal faults can be discriminated even if the fault current includes the large second harmonic. To realize this method by digital relay that has sampling per period, the following algorithm can be adopted. p( t) = V I VI ( R + RG ) I ( R + RG ) I () is stored in the memory, and calculates the next. N _! n W ( t) = { p( t T )} (3) T N n= If W (t) exceeds a threshold, the relay judges there is an internal fault. The threshold be set to avoid the needless operation by the inrush current, and to coordinate the strength of transformer tank and the required clear time. This method is easily applied also to threewinding transformer, and is not affected by the ()

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 7-9, 5 (pp567-57) state of on-load tap changer. This is another merit of the proposed method when the traditional ratio differential relay has to decrease its sensitivity to avoid the error by tap changer. Therefore we can simulate this method by computer. The differential power protection algorithm is shown in fig. Table. Transformer no load specifications Fig. The considered power network Fig. Differential power protection algorithm 3. Simulation results for the largest inrush current Transformer manufacturers simulated various kinds of inrush current using EMTP with their design data. The sensitivity and speed of this method depend on how much the W (t) is increased by the inrush current. Table and show the specifications of transformer. The considered circuit is as shown fig.. Table. Transformer general specifications Fig.3 shows inrush current. Because the secondary terminal was open, the primary winding current only showed. In this case, the peak of primary current (phase B) reaches 4.4 times of the rated current peak. Inrush current is highly unbalanced in the three phase and also contain a lot of harmonics (Fig.4). The principle of the conventional inrush stabilization known since 9 is to filter the nd harmonic of the current. If the ratio nd harmonic to st is above % the CDP detects an inrush current. The algorithms of the PDP are based on power calculation only. These increase the maximum peak of the apparent power. Particularly the distortion active power rapidly increases. Fig.5 shows calculated W (t) of the same case as fig.3.monitoring the maximum of W (t) and its declining, the aim of an inrush stabilization can reached very effectively.

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 7-9, 5 (pp567-57) fault current (three phase to ground) in the case of 5% short circuit at primary winding and Fig.7 shows harmonic components amplitude of the same case as fig.6 in 6MVA transformer. It includes nearly 3% second harmonic and conventional current differential protection relay are locked. Fig.8 shows calculated W (t) of the same case as fig.6 in 6MVA transformer (The faults have been occurred at ms). Fig.3 Waveforms of the maximum inrush current Fig.4 Inrush current harmonic components amplitude Fig.6 Simulation waveform of the fault current (three phase to ground) in the case of primary winding 5% short circuit harmonic value phasea phaseb 3 4 5 6 7 Fig.5 Waveform of the W(t) of the same case as Fig.3 4 phasec 3 4 5 6 7 3 4 5 6 7 harmonic 4. Simulation results of transformer fault Transformer manufacturers simulated various kinds of faults using EMTP with their design data [7-9]. The considered circuit is as shown fig.. Fig.6 shows a simulated waveform of Fig.7 fault current harmonic components amplitude

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 7-9, 5 (pp567-57) the current to stabilize against high inrush currents. Fig.8 Waveform of the W(t) of the same case as Fig.6 Fig.9 Power relay output signal of the fault current (three phase to ground) in the case of primary winding 5% short circuit 5. Simulation of power differential relay by using EMTP For power differential relay simulation we can use control system with TACS (Transient Analysis of Control Systems) in EMTP. The output of this program is a control signal, which control the opening/closing of the transformer circuit breaker. For simulating the circuit breaker we must use TACS control switch, which is known by code3. In this type of switch if the control voltage is positive the switch remained closed. And otherwise the switch will be opened [-]. Typically power differential relay algorithm implementation for transformer with YNd vector group is simulated. The considered circuit is as shown in Fig.. Afterward relay operation for fault condition considered in section IV is presented. For demonstrating the relay operation we can use relay output signal, which this signal is positive in normal and energizing condition and also is zero for fault condition. Fig.9 shows the power differential method was able to discriminate every fault case in this model from inrush. Such faults can be analyzed much faster (less than ms) and more sensible with the new power differential relay than with a conventional current differential protection relay. It is to stress at this point that the power differential relay does not perform any FFT on Power differential relay block diagram is shown in Fig. Fig. Power relay internal daigram 6. CONCLUSION Power based differential protection for three phase transformers have advantages to the conventional current differential protection both in speed and in sensitivity of fault detection. It can discriminate an internal fault from inrush

Proceedings of the 5th WSEAS Int. Conf. on SIMULATION, MODELING AND OPTIMIZATION, Corfu, Greece, August 7-9, 5 (pp567-57) independent of the harmonics in differential current, and is effective for the forecasted increase of capacitance in power system where second harmonic in faults current is large. An additional FFT of the current need not to be performed. By combining the current and voltage information, more sensitive detection can be expected. As power is a criterium which neither depends on the frequency nor on the current waveform. The power differential protection can be used for phase shifter transformer and FACTS devices, Where existing protection relay have no possible mode of operation. References [] D.V.Coury, P.G.Campos. Modeling a Power Transformer for Investigation of Digital Protection Schemes, IEEE/Pes and NTUA, October 4-6,998 [] Siemens:Digitaler Differentialschutz 7UT5 Siemens Verlag(995) [3] K.Inagaki, M.Higaki, Digital Protection Method for Power Transformers Based on an Equipment Circuit Composed of Inverse Inductance, IEEE Trans. On Power Delivery, Vol.3, No.4,October 988, PP(5-5). [4] A.G.Phadke, J.S.Throp, A New Computer- Based Flux-Restrained Current-Differential Relay For Power Transformer Protection, IEEE Transaction on Power Apparatus and Systems, Vol.PAS- No. pp.434-369,november 983 [5] A.Wiszniewski,B.Kasztenny, A Multi- Criteria Differential Transformer Relay Based on Fuzzy Logic, IEEE Trans.On PWRD,Vol.,No.4,Oct.995,PP(787_79). [6] K.Yabe, Power Differential Method for Discrimination Between Fault and Magnetizing Inrush Current in Transformers, IEEE Trans. On Power Delivery, VOL., JULY 997, PP(9 8). [7] P.Bastard,P.Bertrand, A Transformer Model For Winding Fault Studies, IEEE Trans.on Power Delivery,Vol.9,No.,April 994,PP(69-699). [8] P.Palmer,K.L.Butler, Simulation of Incipient Transformer Faults, Circuit and System, Proceeding, 998 Midwest Symposium On,999,PP(5-53). [9] EMTP,Manual, Alternative Transient Program Rule Book, Leuven EMTP Center(LEC),July 987. [] X.Bui,S.Casoria, EMTP Tacs Fortran Interface Development For Digital Controls Modeling, IEEE Trans.On Power Systems,Vol.7, No.,February 99, PP(3-8). [] S.Lefebvre,J.Mahseredjian, Improved Control Systems Simulation In The EMTP Through Compensation, IEEE Trans.On Power Delivery, Vol.9, No.3, July 994,PP(654-66). [] S.Chimklai, J.R.Marti, Simplified Three- Phase Transformer Model For Electromagnetic Transient Studies, IEEE Trans. On Power Delivery, VOL.,No 3, JULY 995