Vertebral Body Derotation System Guide and Ordering Information

Similar documents
Optima ZS Spinal Fixation System

D. Greg Anderson, MD Thomas Jefferson University Hospital Philadelphia, PA

Surgical Technique. Deformity - Degenerative. Interbody Fusion. Tumour - Trauma. Cervical. Emerging Technology

URS Degen. Top loading pedicle screw system for posterior stabilization.

BLACKBIRD Spinal System

ACLP Anterior Cervical Locking Plate System TECHNIQUE GUIDE

VECTRA SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

Thoracolumbar Solutions. Vitality Spinal Fixation System. Surgical Technique Guide

VECTRA. SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

Reflex TM Surgical Technique. Anterior Cervical Plate

Top Loading Pedicle Screw and Hook System for Posterior Stabilization. URS System. Surgical Technique

OPERATIVE TECHNIQUE COVER IMAGE OPTIONAL (DETAIL) IMAGE FIREBIRD NXG. spinal fixation system

Pangea Degenerative Spine System. Top Loading Preassembled Pedicle Screw System for Posterior Stabilization of the Thoracolumbar Spine.

ACCS Anterior Cervical Compression System TECHNIQUE GUIDE

Vectra, Vectra-T and Vectra-One. Anterior cervical plating for spinal fusion.

SYnaPSe oct SYSteM. An enhanced set of instruments and implants for posterior stabilization of the upper spine

A M E D S MART SOLUTIONS FAMILY MEMBER

Synapse System. An enhanced set of instruments and implants for posterior stabilization of the upper spine.

PAC PLATE A N T E R I O R C E RV I CA L P L AT E SYST E M S U R G I C A L T E C H N I Q U E

Gibralt. Occipito-Cervico Thoracc System. Operative Technique

POLYAXIAL SPINE SYSTEM

CD HORIZON REDUCTION MULTI AXIAL SCREW. Spinal System Technical Guide

SURGICAL TECHNIQUE. SpineTune THORACO-LUMBAR POSTERIOR OSTEOSYNTHESIS SYSTEM

Aviator Anterior Cervical Plating System Surgical Technique

Technique Guide. Occipito-Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput.

Interlagos Retractor System Surgical Technique

S 4. Aesculap. Spinal System. Percutaneous Approach Surgical Technique. Aesculap Spine

Lineum OCT Spine System

MaxAn Anterior Cervical Plate System

VBOSS Surgical Technique

Thoracolumbar Solutions. Polaris. Deformity System. Trivium. Derotation System. Surgical Technique Guide

Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation

Technique Guide. Synapse System. An enhanced set of instruments and implants for posterior stabilization of the cervical and upper thoracic spine.

UNIQUE PATIENTS SPECIFIC INDICATIONS IN ONE SYSTEM. Surgical Technique

UNIQUE PATIENTS SPECIFIC INDICATIONS IN ONE SYSTEM. Surgical Technique

Surgical Technique. Anterior Cervical Plating System

ACP 1. Anterior Cervical Plating System. Surgical Technique

Surgical Technique. and Ordering Information

VBOSS. Surgical Technique. Vertebral Body Support System

CSLP Variable Angle. For Use with the Cervical Spine Locking Plate System TECHNIQUE GUIDE. Self-drilling Screw. Variable Screw Angulation

Technique Guide. Synapse System. An enhanced set of implants and instruments for posterior stabilization of the cervical and upper thoracic spine.

Occipito-Cervical Fusion System

Aesculap Spine S 4 Spinal System. Instrumentation Guide

OCCIPITO-CERVICAL FUSION SYSTEM Implants and instruments designed to optimize fixation to the occiput

Nakoma-SL Anterior Cervical Plating System Surgical Technique

Surgical Technique ANAX TM OCT. Spinal System

SYNAPSE SYSTEM An enhanced set of implants and instruments for posterior stabilization of the cervical and upper thoracic spine

Occipito-Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput.

Cervical Solutions. Lineum OCT. Spine System. Surgical Technique Guide

V2F Anterior Fixation System

Part of the DePuy Synthes Cannulated Screw System. 3.5 mm Cannulated Screws

POLYAXIAL SPINE SYSTEM SURGICAL TECHNIQUE

Xia 3 Reference Guide. Version 3-August 2015

3.5 mm Cannulated Screw Technique Guide

ThinLine Anterior Cervical Plate

QUANTUM SPINAL. Presenter: John Perala, Product Manager. August 14, 2006

OPERATIVE TECHNIQUE CENTURION POSTERIOR OCCIPITAL CERVICO-THORACIC (POCT) SYSTEM

TRULY POLYAXIAL, SOLID AND POWERFUL

ThinLine. Surgical Technique. Anterior Cervical Plate. zimmerspine.com

MEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET. for Intramedullary Nail System

Instruments for Removing DePuy Synthes Screws. Screw Removal Set

For Minimally Invasive Application of Cerclage Wires. Cerclage Passer. Surgical Technique

REXIOUS SPINAL SYSTEM

MODEL M1023 QUICK CHANGE COLLET ATTACHMENT INSTRUCTION MANUAL. Phone: On-Line Technical Support:

7.0 mm Cannulated Screws

Technique Guide. 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Door window. Front door window, assembly overview

SlimLine Anterior Cervical Plate

Passage 4 Bike Hitch Rack

Virage OCT Spinal Fixation System

Cerclage Passer. For minimally invasive application of cerclage cables.

Technique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Back to health. Back to work. Back to life.

Knee Nail for Retrograde Femoral Mode

Page 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications

Lateral Mass Fixation Surgical Technique. and Product Catalog. Distribution For EU Only

mila-wall (Series100) General Operating Instructions page 1 of 15

Table of Contents 2-6. Introduction. Indications Surgical Technique. Ordering Information 15-24

Mechanical Frappe Press

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

6.5 mm and 7.3 mm Cannulated Screws Technique Guide

HERO. Cervicale plate system

MATRIX COMBO PLATING SYSTEM. Streamlined set for craniofacial and mandibular trauma and reconstruction

Hollywood Swing Away 2 and 4 Bike Racks Assembly and Installation Guide

INSTRUCTION SHEET STRUT DRIVER RETROFIT KIT PN: 22-79SDRF

Reflex Hybrid System Overview

90 SCREWDRIVER Minimally invasive drilling and screw insertion

RULTRACT RETRACTOR CABLE REPLACEMENT INSTRUCTIONS. Rultract, Inc. is the ONLY authorized service center in the U.S.A.

Ankle Fracture System. Surgical Technique STRENGTH FROM WITHIN

INSTRUCTION MANUAL. X-Wedge for LX200 and LX600 telescopes _07028_XWedge_InstructionManual.indd 1

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

SERVICE MANUAL For UHR and VR series

Installation Instructions Hinged Roof Rack

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Maintenance Information

,... - '-. ) * cited by examiner US B2. c12) United States Patent Wolinsky et al. (10) Patent No.: US 9,161,787 B2

AUC Cell Assembly Torque Stand. User Manual

3.5 mm/2.7 mm LCP. Pancarpal Arthrodesis Plate. For treatment of carpal joints in dogs

Aviator Anterior Cervical Plating System System Overview. Visual and tactile confirmation Increased Angulation Simplified instrumentation

SawStop. T-GlideTM. Fence System- Professional Series II OWNER S MANUAL

Transcription:

Vertebral Body Derotation System Guide and Ordering Information

Introduction DePuy Spine continues to support the goal of providing solutions to surgeon challenges when treating spinal disorders. Collaborating with renowned spine specialists, the Company has developed a new set of vertebral body derotation instrumentation especially designed for the Expedium Spine System. The Expedium Vertebral Body Derotation (VBD) Set design allows for an easy and quick attachment & release to the screws involved in the correction maneuver, without compromising the security surgeons require in such connection. The set also includes a selection of instruments that let the surgeon connect the derotation instrumentation at each vertebral level (Segmental Derotation), at multiple vertebral levels along the spine (EnBloc Derotation) or both ways. The input of each surgeon designer relative to their derotation technique, allowed DePuy Spine to develop a set that will accommodate the techniques mentioned above, as well as muscle sparing approaches involving DePuy Spine s Minimally Invasive System, the Viper 2 System. The Expedium family of products includes a wide selection of deformity specific implants and instruments to support the DePuy Spine philosophy of patient driven, pathology specific solutions.

Contents Introduction 2 System Information 4 Set Components 5 Vertebral Body Derotation Instruments 5 Reduction Instruments 7 Surgical Technique 8 Attaching/Releasing the Quick Sticks 8 Connecting the Quick Sticks with the Derotation Frame 9 Adding Modular Clamps 10 Tightening and Loosening the Knobs 11 Adding the Derotation Handle 12 Connecting the Quick Sticks with the Alignment Fork 13 Placing the Rod with the Reduction Handle 14 Rod Reduction for Screw Extensions 15 Ordering Information 16 Product Codes 17

System Information

SET COMPONENTS The Expedium Vertebral Body Derotation (VBD) Set includes key components designed to facilitate the vertebral body derotation maneuvers to achieve a 3D correction of the scoliotic spine. Among those components are: Figure 1 Vertebral Body Derotation Instruments The Expedium VBD Set includes two options for derotation maneuvers: a. Expedium Quick Sticks b. Viper 2 Screw Extensions Both instruments are completely compatible and easily attach to the pedicle screw to act as a lever for the derotation maneuver. The Expedium Quick Sticks are used when speed and strength of instrument/screw attachment are the priorities. The VIPER 2 Screw Extensions can be used when there is limited room for all the instrumentation for derotation and a thinner instrument is needed. Expedium Quick Stick and Viper 2 Screw Extension The Expedium VBD set includes several options that allow the surgeon to connect the derotation instruments (Quick Sticks and/ or Viper 2 Screw Extensions) across vertebral levels for Segmental Derotation, along the spine for EnBloc Derotation or a combination of both. 5

SYSTEM GUIDE Figure 2 The options to connect the Quick Sticks are: a. derotation Frame: attaches to the top of the derotation instruments via fixed or modular Clamps, allowing the surgeon to connect two or more derotation instruments together. Expedium Quick Sticks connected with Derotation Frame Figure 3 b. alignment Fork: quickly connects the derotation instruments as an initial step to give the spine proper alignment. It allows more freedom of movement of the derotation instruments in the sagittal plane. Alignment Fork and Derotation Handle 6

Figure 4 Reduction Instruments The VBD Set is compatible with the Expedium Flex-Clip through an updated Insert that can be also linked together with any of the derotation instruments mentioned before. Expedium Flex-Clip Insert connected to Quick Stick Figure 5 The Expedium VBD Set includes the Viper 2 Reduction Handle to facilitate rod placement through either the Quick Stick or the Screw Extension. Viper 2 Screw Extension with Reduction Handle 7

SYSTEM GUIDE SURGICAL TECHNIQUE Figure 6 ATTACHING/RELEASING THE QUICK STICKs 1. Slide the Quick Stick Sleeve all of the way up into the open position and place the end of the Quick Stick over the head of the pedicle screw. Line up the rod slot of the Quick Stick with the rod slot of the screw. 2. Push the Quick Stick onto the pedicle screw by pushing on the back end of the Quick Stick. The Quick Stick will connect to the top notch of the pedicle screw with a subtle snap sound. Lower the outer sleeve of the Quick Stick completely down to click it into place. 3. to remove the Quick Stick, move the outer sleeve up until it clicks into place and pull the Quick Stick off of the pedicle screw by pulling on the end of the Quick Stick. 8

Figure 7 CONNECTING THE QUICK STICKS WITH THE DEROTATION FRAME 1. confirm that the knob of the Clamp(s) is backed off from fully closed. Push the Quick Stick into the Clamp until you hear/feel a subtle click. Tighten the knob to secure the connection between the Clamp and the Quick Stick. 2. to remove the Quick Stick from the Clamp, unscrew the knob and pull the Quick Stick out. 9

SYSTEM GUIDE Figure 8 ADDING MODULAR CLAMPs 1. open the Modular Clamp by unthreading the knob completely and pulling the two halves apart. 2. Place the Frame into the open Modular Clamp. Close the Modular Clamp over the Frame and snap the lock feature which will hold the two sides of the Modular Clamp closed before the threads are engaged. 3. to start the thread feature, push the inside Clamp towards the knob and thread the knob. (The pushing force will help to start the engagement of the threads). Do not fully thread the Clamp before attaching the Quick Stick or it will not snap into place. 4. Press the Quick Stick into the Clamp until it snaps into place. Tighten the knob on the Modular Clamp to lock the Quick Stick into place. 5. to remove, unthread the knob to release the Quick Stick. Fully unthread the Clamp and pull the two halves of the Clamp apart. The Clamp will separate and the lock feature will disengage allowing the Clamp to be removed from the frame. 10

Tightening and loosening the knobs 1. connect the Inline and/or the Offset wrenches to the knobs to tighten or loosen the Clamps. Figure 9 Figure 10 11

SYSTEM GUIDE Figure 11 ADDING THE DEROTATION HANDLE 1. unthread the knob on the Derotation Handle one full revolution from the fully threaded condition. 2. Snap the handle to the frame and tighten the knob to secure the connection. The Derotation Handle can be mounted in either a perpendicular or inline orientation on the frame. 3. to remove the Derotation Handle, unthread the knob one full revolution and press the button on the side of the handle. 12

Figure 12 CONNECTING THE QUICK STICKS WITH THE ALIGNMENT FORK 1. attach the Derotation Handle to the end of the Alignment Fork. The handle will attach in similar fashion to the frame attachment. 2. Slide the Tuning Fork over the Quick Sticks or Screw Extensions. 3. When the Alignment Fork is engaged over the Quick Sticks, the closure mechanism can be pivoted into the closed position turning the knob to tighten. 13

SYSTEM GUIDE Figure 13 PLACING THE ROD WITH THE REDUCTION HANDLE Rod Reduction for Quick Sticks 1. engage the Threaded Post over the Self Retaining Reduction Driver and snap it into place. 2. Load the set screw in the Self Retaining Reduction Driver. Place the driver down through the Quick Stick. 3. engage the Reduction Handle with the Threaded Post/Reduction Driver assembly. 4. turn the bottom Reduction Handle and reduce the rod until resistance is felt (when the set screw contacts the top of the pedicle screw). Begin turning the top Reduction Handle to start engaging the set screw into the pedicle screw, continue turning the bottom Reduction Handle to maintain the reduction force on the rod. 5. Once the set screw is fully seated, thread out the Threaded Post by turning the bottom Reduction Handle counterclockwise and remove the complete assembly. 14

Figure 14 Rod reduction for screw extensions 1. Snap the Screw Extensions onto the pedicle screw and tighten them with the MIS Nut Driver. 2. Snap the Reduction Cap onto the Screw Extension by aligning the etched lines. After the Reduction Cap has snapped into place, lower the locking ring on the Reduction Cap to secure the instrument to the Screw Extension. Follow the same steps described for Reduction with the Quick Sticks. 3. to remove the Reduction Cap from the Screw Extension, raise the locking ring all of the way up and pull the Reduction Cap off of the Screw Extension. Figure 15 15

Ordering Information

ORDERING INFORMATION Code Description CASE 1 of 2 2797-89-007 Derotation and Connection Case & Lid DEROTATION TRAY 2797-89-005 Derotation Tray 2797-88-935 Expedium Derotation Quick Stick 2797-88-882 Expedium Deortation Modular Frame (image shows frame with 2 x modular clamps attached) CONNECTION TRAY 2797-89-006 Connection Tray 2797-88-965 Expedium Derotation Modular Clamp (image shows 2 x modular clamps attached to frame) 2797-88-867 Expedium Derotation Frame Inline Wrench 2797-88-868 Expedium Derotation Frame Offset Wrench 2797-88-869 Expedium Derotation Quick Stick Anti Torque Wrench 2797-88-930 Expedium Derotation Alignment Fork 2797-88-960 Expedium Derotation Frame Handle 17

SYSTEM GUIDE ORDERING INFORMATION Code Description CASE 2 OF 2 2797-89-007 Outer case SCREW EXTENSION TRAY 2797-89-009 Screw Extension Tray 2867-25-225 Viper 2 Screw Extension 2867-25-405 Castle Nut Remover 2867-25-400 Viper 2 Castle Nut Tightener 2867-25-420 Viper 2 Castle Nut Tightener/Removal Sleeve 2867-25-410 Viper 2 Castle Nut Tightener/Removal Shaft 2797-88-872 Expedium Derotation Flex-Clip Insert 2867-35-750 Expedium Derotation Reduction Cap REDUCTION TRAY 2797-89-003 Reduction Tray 2867-35-725 Expedium Derotation Reduction Shaft 2867-35-730 Expedium Derotation Reduction Threaded Post 2867-35-735 Expedium Derotation Reduction Handle 2867-35-400 Viper 2 Set Screw Inserter 18

4.5 Spine System 5.5 Spine System 6.35 Spine System Vertebral Body Derotation Set SFX Cross Connector System Anterior Spine System Viper 2 System INDICATIONS The Expedium Spine System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine. The Expedium Spine System is intended for noncervical pedicle fixation and nonpedicle fixation for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis, and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion in skeletally mature patients. Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. This publication is not intended for distribution in the USA. Never Stop Moving is a trademark of DePuy International Ltd. SFX is a trademark and Expedium and Viper 2 are registered trademarks of DePuy Spine, Inc. 2011 DePuy International Limited. All rights reserved. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England. Registered in England No. 3319712 Cat No: 9084-76-000 version 1 DePuy International Ltd St. Anthony s Road Leeds LS11 8DT England Tel: +44 (0)113 387 7800 Fax: +44 (0)113 387 7890 0086 Issued: 01/11