Electricity Meter Test System

Similar documents
Combination Wave Test System

Insulation Test System

Insulation Test System

Telecom Test System. Lightning Tests

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

Low Frequency Measuring System

MILITARY & AEROSPACE TESTING

Avionics Test System. Lightning Tests

Technical Specification

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

ESD Test System. Immunity Tests

Technical Specification

Conducted Immunity Testing

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

Advanced Test Equipment Rentals ATEC (2832)

Low Frequency Measuring System

2620 Modular Measurement and Control System

Immunity Testing for the CE Mark

Surge Generator for MIL-STD 1275

Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

CAR - TEST - SYSTEM 14

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Schlöder GmbH - EMC Test and Measurement Systems Model #

EMC standards. Presented by: Karim Loukil & Kaïs Siala

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

IEC Electrical fast transient / Burst immunity test

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

CS114 + CS115 + CS116

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

EMC Test report for LED Panel Light Models , , , , ,

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

satech SynchroStar GPS 200 Series

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Voltage Transient Emission Test

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

2520 Pulsed Laser Diode Test System

DOBLE F6150e TECHNICAL SPECIFICATIONS

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Network Analyzer for Low-, Medium- and High-Voltage Networks

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

METRAClip87 and 88 Clamp Multimeters

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

Lightning Surge Simulator LSS-F03 series

Emerging Standards for EMC Emissions & Immunity

RF Conducted Immunity and Automotive Transient Generator Test Systems

LS200 TEST DATA IEC61000 SERIES

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

Fast transient burst simulator

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Overcurrent Protection / 7SJ45

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

DOBLE F6150SV TECHNICAL SPECIFICATIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

Laboratory Accreditation Programmes

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EMC Test Report. Report Number: M030826

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 11 to 15 April EMC standards

Novità sulla IEC ; -10; -12

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Test Specification for Type Approval

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EMC TEST REPORT. Report No.: CE10-LIE040101E

Accr. 002-Test EN-ISO (2005)

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC test report AU01+E04

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

Types of EMC measures

CONDUCTED IMMUNITY EMC TEST SYSTEM

TEST REPORT... 1 CONTENT...

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Compliance to a standard or to the real world?

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

automotive EMC solutions

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Center for Quality Engineering. Test Report No.: B0EF0002

Partners for HV and EMC Solutions MIL-STD-461 G. Partners for HV and EMC Solutions

INTERNATIONAL STANDARD

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

TEST REPORT. Power Spout PLT V. tested to the specification

Transcription:

Component Tests Electricity Meter Test System System Overview.................... 3 Features & Benefits................... 4 Standards....................... 6 Application Options................... 7 Generator Overview................... 8 Generator Specifications................. 10 Accessories and Options................. 13 TEMA3000 Software.................. 14 EMC PARTNER s Product Range.............. 15 Electricity Meter Test System 1

Full Electricity Meter Test Solution Single Port testing system Three phase testing using a single connection point for the EUT is labour saving and eliminiates potential operator error. EMC Partner systems for EFT, Surge and DOW can all be coupled through one single device: The CDN3000A-06-32 2 Electricity Meter Test System

Testing of electricity meters has evolved to take account of the increasing use of electronics. Apart from tests of electrical safety, Electricity meters must be tested for Electromagnetic Compatibility (EMC) relevant to the installation environment and in more modern electricitry meters, tests against disturbance caused by mains signalling must be conducted. EMC PARTNER specialize in test equipment to simulate the impulse and short duration disturbances that can be propogated down the power mains. By their very nature, most electricity meters are required to operate in three phase power main systems. Impulse Voltage Tests Impulse transients can be generated by external events such as lightning or internal events like switching. The result is a voltage impulse with low energy content that appears between windings in transformers, between power lines or across physical gaps between conductors and cases etc. A normalised voltage impulse of 1.2/50us is defined in the standards IEC 60060-1 and IEC61180-1. Fast Transient (Burst) Tests Industrial measurement and control equipment nearly always use conventional control units containing relays or other electro-mechanical switching devices. Fluorescent lamp ballast units, insufficiently suppressed motors (hair dryers, vacuum cleaners, drills, etc.) are found everywhere in the public power supply. EFT is defined in the basic standard IEC 61000-4-4 Combination Wave Tests (CWG) Surge events are generated by lightning phenomena, switching transients or protection devices in the power distribution system. A surge is influenced by the propogation path resulting in different forms depending upon where a measurement is taken. Combination Wave Generators (CWG) simulate a surge event in power lines close to or within buildings. Surge is defined according to IC 61000-4-5 Dips & Interrupt Tests Voltage failures occur following switching operations, short-circuits, response of fuses and when running up heavy loads. The interference sources in the mains, caused by electronic power control with non-linear components e.g. thyristors are used more frequently in domestic appliances. IEC 61000-4-11 defines DIPS & Interrupts. Damped Oscillatory Waves (DOW) Damped oscillatory waves occur mainly in power, control and signal cables installed in air insulated (AIS) high voltage and medium voltage (HV/MV) substations. The event has a relatively high transfer impedance resulting in a voltage impulse. A normalised voltage impulse of a damped sinewave as defined in the standards IEC 61000-4-18 and ANSI C37.90 are an industry standard. Electrostatic Discharge Tests The capacity of the body can be charged to several kilovolts and is discharged when contact is made with an electronic unit or system. The discharges are harmless to humans, but not to sensitive, electronic equipment. The resulting currents cause interference or even component damage. ESD is defined in IEC 61000-4-2. Differential Mode Testing Designed according IEC61000-4-19 to generate and inject differential mode disturbances in the frequency range 2 khz 150 khz, the system allows testing smart electricity meters or different devices connected to the AC power network, where disturbances from mains signalling, inverters or other power electronics is present. Electricity Meter Test System 3

Features Single Port Testing - Fast Transient / Burst tests - Damped Oscillatory Wave Tests 100kHz & 1MHz - Combination Wave Tests - Dips and Interruptions - 3-Phase Power Line CDNs up to 690V Class I + Class II - Test level to 6kV or 12kV - Impulse tests with 0.5Joules and 500 ohm - Impulse tests with 9Joules and 500 ohm - Single phase meter tests up to 280V - three phase meter tests up to 690V Electronic Smart meters - Differential Mode testing - According to IEC 61000-4-19 - Referenced in EN 50470-1 and pr TR 50579 - Integrated 25A current source to load meters - 2kHz to 150kHz All test types included - Insulation tests up to 12kV - Electrical tests single and three phase - EMC tests - special Interrupt tests - Load to Line tests up to 20kV Software control - Product tests in software library - Programing remotely on a computer - Test report parameters selectable - Test report format selectable - Create user defined sequences 4 Electricity Meter Test System

Benefits Less operator error - Automated test routines - Less user intervention in setups - Test report automatically generated in pdf format - Simple EUT connections using standard sockets - Coupling path selection pre-programed Faster testing - Minimum system learning time - Easy to follow interface - EUT monitoring - Easy setup - Higher test throughput Return on investment - Reduces non-productive time - Spend time testing only, get the job done - Software operation speeds data collection - High impulse integrity, no need for retests - Operator training time minimum Complete Test Report - Test results collected automatically - User defined information in report - Add company logo and set report format - Integrate different test types into one report - Create report in the file format you want Service Friendly - Easy firmware update from EMC PARTNER.com - Discrete tests in generators, reduced downtime - Minimum calibration accessories - BNC outputs to verify generator output - Operator safety ensured Electricity Meter Test System 5

Applicable Standards Product Standards International Electrotechnical Committee (IEC) IEC 62052-11 (2003). Electricity metering equipment (AC) General requirements, tests and test conditions Part 11: Metering equipment IEC 62053-21 Ed 2 (2003) Electricity metering equipment (a.c.) Particular requirements Part 21: Static meters for active energy (classes 1 and 2) IEC62055-31 (2005) Electricity metering Payment systems Part 31:Particular requirements Static payment meters for active energy (classes 1 and 2) American National Standards Institute (ANSI) C12.1 (Date): American National Standard for Electric Meters. Code for Electricity Metering. C12.20 (Date): American National Standard for Electricity Meters 0.2 and 0.5 accuracy class C37.90.1: IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems associated with Electric Power Apparatus National Ministry (Australia) AS 62052-11 (2005): Electricity Metering Equipment (AC) General Requirements, Tests and Test Conditions Metering Equipment (modified from IEC 62052-11 (2003)) NMI M6 (2009): Pattern Approval and Verification of Electricity Meters: Definitions, Metrological and Technical Requirements European Standard EN50470-1: Electricity metering equipment (a.c.) Part 1: General requirements, tests and test conditions - Metering equipment (class indexes A, B and C) Basic Standards International Electrotechnical Committee (IEC) IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test. IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test. IEC 61000-4-5: Testing and measurement techniques - Surge immunity test. IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test. IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests. IEC 61000-4-18 Ed2 (2009): Electromagnetic compatibility (EMC) - Testing and measurement techniques - Damped oscillatory wave immunity test. IEC 61000-4-19 : Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2Hz to 150kHz at ac power ports. IEC 61000-4-34: Testing and measurement techniques - Voltage, dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase. 6 Electricity Meter Test System

Application Options Electricity Meter Energy meter testing is a complex and lengthy affair. With EMC PARTNER impulse test equipment, the insulation test, Eelctrical tests and Electromagnetic Compatibility tests (EMC) are reduced to managable levels. Your aim is to test and approve electricity meters as fast as possible. EMC PARTNER can help. Smart Meter The addition of electronics and control interfaces to energy meters has created the need for more tests to ensure reliable energy measurement and reporting. In particular when mains signalling is used, there is a need to perform differential mode tests on the power interfaces. IMU SMART SLAVE V1I1 accomplishes this task in a single unit including the CDN to decouple interference signals from a reference meter and also a 25A current source to allow I b setup without external equipment. Electricity Meter Equipment Guide STANDARDS IMU3000/4000 F-S-D-V-C IMU SMART SLAVE I1 V1 MIG1203CWG ESD3000 or EXT-TRA3000E* MIG-OS-OS1 MIG1803 + NW-NMI-M6C3C4 MIG2412 IEC61000-4-2 ESD IEC61000-4-4 EFT IEC61000-4-5 CWG IEC61000-4-16 Common mode IEC61000-4-19 Differential mode SP Method 1618 IEC62052-11 IEC62053-21 IEC62055-31 ANSI C12.1 ANSI C12.20 NMI-M6 EN50470-1 External Options NW-IEC61036C1 + C2 CDN3000A-06-32 PS3 CN-MIG18 AMP CN16 EXT-TRA3000 C-SHORT MF1000-1 & MF1STAND VAR-EXT1000 (1-PHASE) PFS32 + SRC32 (3-PHASE) Electricity Meter Test System 7

Generators Because there is such a wide range of testing required for electricity meters, several unique stand-alone generators are required. Test equipment from other product areas can be used and the relevant generators are referenced in this brochure. For full technical specifications, please refer to the corresponding equipment brochure as noted below the relevant product. Insulation Tests MIG0603CWG and MIG1203CWG include two different impulse types. The voltage impulse with a source impedance of 40Ω and a combination Wave Generator (CWG) witha source impedance of 2Ω. The 1.2/50µs impulse voltage connections made by screw terminals on the generator top plate and the CWG connections (up to maximum 6kV/3kA) are through 4mm connections on the instrument front panel. Because the high voltage terminals on the top plate are exposed, a protective device such as the TC-MIG24 test cabinet is necessary. For further details refer to the brochure System Automation Hardware Accessories. MIG0603OS2 Class I MIG0603OS2 For Class I equipment, a test up to 6kV is sufficient. The MIG0603OS2 can therefore be used. Energy 0.5J, Impedance 500 Ohm. Lightning impulse tester 1.2/50µs voltage range 0.5kV up to 6kV. CWG impulse 1.2/50µs (8/20µs) range 0.25kV(0.125kA) up to 6kV(3kA). Class 2 MIG1203CWG + NW-IEC61036C1 + NW-IEC61036C2 + CN-MIG18 AMP MIG1203CWG For Class II equipment, a test up to 10kV is needed. The MIG1203CWG is appropriate. Lightning impulse tester 1.2/50µs voltage range 0.5kV up to 12kV. Lightning impulse tester 1.2/50µs voltage range 0.5kV up to 12kV. Energy 0.5J, Impedance 500 Ohm. CWG impulse 1.2/50µs (8/20µs) range 0.25kV(0.125kA) up to 6kV(3kA). Impulse magnetic field with MF1000-1 (1m x 1m) 90 A/m up to 2,100 A/m Line to Load MIG2403 For line to load voltage surge testing, an impulse up to 20kV with 80 Ohm impedance is required. MIG2403 with an external impedance box can fulfill this requirement. Lightning impulse tester 1.2/50µs voltage range 1kV up to 24kV MIG2403 + TC-MIG24 Electrical Tests IMU4000 + VAR1000-EXT (1 Phase) or PFS32 + SRC32 (3 Phase) Within this category of tests, are interrupt and dip requirements specific to energy metering equipment. Provided as standard within EMC PARTNER dip testers, the special dip requirements are pre-programed for easier access. 8 Electricity Meter Test System

Generators Electro-Magnetic Compatibility (EMC) Tests As part of the test schedule, a range of EMC tests are called upon. These include Fast transient/burst, Damped Oscillatory Wave, Electrostatic Discharge and Surge Immunity tests. For all EMC tests, a coupling / decoupling network (CDN) is also required. Damped Oscillatory Waves (DOW) MIG-OS-OS1 The classic damped oscillatory wave generator for IEC, EN and ANSI applications. The slow waves are available through either balanced differential or grounded outputs. The 100kHz and 1MHz waveforms can be programmed up to 3000V. This generator is ideal for applications requiring only the slow waves. For Electricity Meter testing, a three phase coupling de-coupling network (CDN) is required. MIG-OS-OS1 For further information, refer to the Oscillatory Wave Test System brochure. Electrostatic Discharges (ESD) ESD3000 ESD3000 is a light weight, hand-held battery operated tester. The modular construction enables many different test standards to be performed by simply changing the module. A broad range of accessories enable testing to many applications for contact discharge, air discharge and indirect discharge. ESD3000 For further information, refer to the ESD Test System brochure. Electric Fast Transient (EFT) & SURGE IMU4000 IMU4000 is the latest generation EMC immunity tester. Employing a modular design, IMU4000 can be configured to meet the Fast transient / Burst, Surge and Interrupt test requirements for electricity meters. The 7 touchpanel display enables a fast and intuituve control of the generator. ESD Extension (EXT-TRA3000-E) up to 16 A (AD) & 10A (CD) available to this System. For further information, refer to the IMU4000 brochure. Differential Mode IMU SLAVE SMART I1V1 The new IMU SMART series from EMC Partner enables customers to start performing fully automatic tests according to IEC 61000-4-19. Designed to generate and inject differential mode disturbances in the frequency range 2 khz 150 khz, the system allows testing smart electricity meters or different devices connected to the AC power network, where disturbances from mains signalling, inverters or other power electronics is present. IMU3000 IMU4000 IMU SLAVE SMART I1V1 Electricity Meter Test System 9

Generator Specifications Test of insulation properties MIG0603OS2 Insulation Test Circuit Voltage range 0.5 up to 6kV Pulse front time 1.2µs Pulse duration 50µs Source Impedance 500ohm Impulse energy 0.5Joules Polarity positive, negative, alternating Combination Wave Test Circuit Voltage range Current range Source Impedance Polarity 0.25 up to 6kV 0.125 up to 3kA 2ohm positive, negative, alternating MIG1203CWG + NW-IEC61036C1 + NW-IEC61036C2 + CN-MIG18 AMP Insulation Test Circuit Voltage range 0.5 up to 12kV Source impedance 40ohm and 500ohm (selectable) Impulse energy 420Joules and 0.5Joules (selectable) Pulse front time 1.2µs Pulse duration 50µs Polarity positive, negative, alternating Combination Wave Test Circuit 6kV Voltage range 0.25 up to 6kV Voltage Pulse 1.2µs / 50µs Current range 0.125 up to 3kA Current Pulse 8µs / 20µs Source Impedance 2ohm Polarity positive, negative, alternating MIG2403 Line to Load Test Circuit Voltage range 1 up to 24kV Source impedance 40ohm Impulse energy 840Joules Pulse front time 1.2µs Pulse duration 50µs Polarity positive, negative, alternating * for more details please read the generators brochure & technical specifications 10 Electricity Meter Test System

Generator Specifications Tests of Electromagnetic Compatibility MIG-OS-OS1 Voltage range Oscillation frequencies Voltage increment Burst repetition rates Phase angle synchronization Source Impedance Pulse front time Polarity 0.2A up to 3kV 100kHz, 1MHz 1V steps 40Hz, 400Hz 0 up to 360 in 1 steps 200ohm 75ns positive, negative ESD3000 + ESD3000DM1 Air Discharge 0.1 up to 16kV Contact Discharge 0.1 up to 10kV Contact Discharge Repetition 0.05 to 30s Discharge Counter 1 to 29999 Discharge Polarity Positive / Negative Discharge Trigger Manual or Automatic IMU3000 / IMU4000 EFT/Burst EXT-IMU3000 F / F5 / F6 Pulse front time Pulse duration Voltage range into 1000ohm Source Impedance Spike Frequency Burst Duration Burst Repetition Polarity IMU3000 / IMU4000 Surge EXT-IMU3000 S / S6 Voltage range 5ns 50ns 0.125 up to 2kA 50 ohm 1kHz up to 1MHz 0.01ms up to 30ms 1 up to 1000ms Positive, Negative 0.25 up to 4kV (IMU4000) 0.25 up to 6kV (IMU3000) 0.25 up to 8kV (IMU3000) 1.2µs Pulse front time Pulse duration 50µs Current range 0.125 up to 2kA Pulse front time 8µs Pulse duration 20µs Source impedance 2ohm Pulse Repetition 20 per minute * for more details please read the generators brochure & technical specifications Electricity Meter Test System 11

Generator Specifications IMU SLAVE SMART V1 (Voltage Tests) EUT Voltage input EUT Current input 80-500V, L-L or L-N, 50Hz and 60Hz 0-16A L-L or L-N Voltage waveform sinusodial, THD <5% Output frequency range CDN Output impedance 2kHz - 150kHz 10 ±30%, 2 khz 150 khz CDN decoupling as per IEC 61000-4-19 Frequency step 2% standard, adjustable 1% - 100% Dwell time Pause time Signal type Modulation frequency standard Modulation frequency adjustable Measurement and control IMU SLAVE SMART I1 (Current Tests) 3s standard, adjustable 1s - 300s 300ms ± 200ms, adjustable 0.1s - 30s continuous with pause, 50% rectangular modulation 50Hz: 3Hz, 101Hz, 301Hz, 601Hz 60Hz: 4 Hz, 121Hz, 361 Hz, 721 Hz 3 Hz - 1kHz internal, automatic EUT voltage input 80-500V, L-L or L-N, 50Hz and 60Hz EUT Current input 0-25A L-L or L-N Current waveform sinusodial, THD <5% Test current 0.01A (-10%) up to +4A (+10%) tolerance ±10% Output frequency range 2kHz - 150kHZ Output impedance 1 Ohm ±30%, 2 khz - 150kHz Decoupling impedance 1 Ohm ±30%, 2 khz - 150kHz Frequency step 2% standard, adjustable 1% - 100% Dwell time 3s standard, adjustable 1s - 300s Pause time 300ms ±200ms, adjustable 0.1s - 30s Signal type continuous with pause, 50% rectangular modulation Modulation frequency standard 50Hz: 3 Hz, 101Hz, 301 Hz, 601Hz 60Hz: 4 Hz, 121Hz, 361 Hz, 721 Hz Modulation frequency adjustable 3Hz - 1kHz Built-in reference load current source selectable 1-25A, synchronized with voltage imput Measurement and control internal, automatic * for more details about this generator please read the generators brochure & technical specifications 12 Electricity Meter Test System

Accessories and Options CDN3000A-06-32 Automatic three phase CDN with phase voltages up to 690V, line current 32A per phase. Coupling path selection for EFT, Damped Oscillatory, Surge and Ring. Differential input for Damped Oscillatory Waves. TC-MIG24 A test cabinet for EUT with maximum dimensions 20x20x30cm. Can be used together with all Protection Device Testers except the MIG1248 which has its own built-in test cabinet. TC-MIG24 is linked to the MIG tester safety circuit. Opening the test cabinet disables test voltages. Safety circuit status is indicated by red and green lamps in the test cabinet. CDN3000A-06-32 CN-MIG24 EUT connection box with two test pistols, interlock and green / red safety warning lamps. Usable with MIG systems with output on top up to Vmax 18kV (1.2/50µs), Imax 1kA (8/20µs). NW-NMI-M6C3C4 CN-MIG18AMP TC-MIG24 Two test pistols for conducted tests. Cable length 1m with AMP plugs. The test pistols can be used together with MIG systems equipped with AMP plug outputs or togethr with the networks mounted on either MIG0603CWG or MIG1203CWG. NW-NMI-M6C3C4 Network to MIG1803 according to NMI M6 section A.2.19, waveform 1.2/50µs, 10J at 10kV and 12 kv - MIG1803 generator only NW-NMI-M6C3C4 NW-IEC61036C1 Network in accordance with IEC62052-11 section 5.6. 0.5J, 500ohm. Output voltages 800V, 1500V, 2500V, 4000V. For use with - MIG1203CWG - MIG1203 NW-IEC61036C1 NW-IEC61036C2 Network in accordance with IEC62052-11 section 5.6. 0.5J, 500ohm. Output voltages 800V, 1500V, 2500V, 4000V. For use with - MIG1203CWG - MIG1203 NW-IEC61036C2 Electricity Meter Test System 13

TEMA3000 Software Remote control from a PC requires TEMA3000 software and an OPTICAL LINK to galvanically separate the PC from IMU4000. TEMA3000 is a modern software running under Win7 operating systems. The heart of a complex test system, TEMA3000 includes the functions: - Generator control from a PC - Linking of test to form a complex sequence - Library of predefined tests for IEC basic and product standards - Integration of DSOs - Test report generation Generator control from a PC Connected using the Ethernet cable to IMU4000, TEMA3000 opens a window which emulates the EPOS in IMU4000. All parameters are input exactly as on the IMU3000 front panel. Any generator connected to TEMA3000 will be simultaneously programmed over the Ethernet cable. Conversely, parameters entered on IMU3000 are changed in TEMA3000. Linking tests to form a sequence Individual tests stored on the PC or in IMU4000 can be combined to form a complex test sequence. This feature enables ESD, EFT, SURGE, VARIATIONS, DIPS and COMMON MODE tests to be linked and run in a continuous sequence. Apart from tests, other applications can be started, an oscilloscope can be integrated or a message box opened. As a LIBRARY module, pre-defined test routines are available from EMC PARTNER. These cover all IEC basic and generic standards. Control of a DSO A DSO module is available to extend the basic TEMA3000 software package. DSOs with Ethernet and USB interfaces can be controlled from TEMA3000 software. Apart from setting timebase and amplitude, measurement features in the DSO can also be accessed and measurement results added to the test report. Tektronix, Agilent, Lecroy and Rohde & Schwarz models are supported as standard. Test Report Generation TEMA3000 basic module generates a HTML format test report. The basic software can be extended with the PROTOCOL module which enables transfer of report data as.csv files for import into EXCEL, custom report formatting and final reports generated as Adobe.pdf files. Web Server Use any PC with any operating system and internet browser to connect to the internal web server. This enables access to test report and service data either directly on a PC internet browser or using the USB memory stick. Customize the test report by uploading company logo and test information from the USB memory stick. Conversely, by simply selecting the GOTO USB button, test report and service information can be saved directly to the USB memory stick. Communication with a PC is by Ethernet, which again reduces dependancy on obsolete or expensive interfaces. Remote control from a PC is best achieved with the OPTICAL LINK and the TEMA3000 software package. 14 Electricity Meter Test System

EMC EMC PARTNER s PARTNER s Product Product Range Range The Largest Range of Impulse Test Equipment up to 100kA and 100kV. Immunity Tests Hidden Heading to provoke a TOC entry Transient Test Systems for all EMC tests on electronic equipment. ESD, EFT, surge, AC dips, AC magnetic field, surge magnetic field, common mode, damped oscillatory and DC dips. According to IEC and EN 61000-4-2, -4, -5, -8, -9, -10, -11, -12, -13, -14, -16, -18, -19, -29. Lightning Tests Impulse test equipment and accessories for aircraft, military and telecom applications. Complete solutions for RTCA / DO-160 and EUROCAE / ED-14 for indirect lighting on aircraft systems, MIL-STD-461 tests CS106, CS115, CS116 and Telecom, ITU-T.K44 basic and enhanced tests for impulse, power contact and power induction. Component Tests Impulse generators for testing; varistors, gas discharge tubes (GDT), surge protective devices (SPDs), X / Y capacitors, circuit breakers, watt-hour meters, protection relays, insulation material, suppressor diodes, connectors, chokes, fuses, resistors, emc-gaskets, cables, etc. Emission Measurements Measurement of Harmonics and Flicker in 1-phase and 3-phase electrical and electronic products according to IEC /EN 61000-3-2 and 61000-3-3. HARCS Immunity software adds interharmonic tests, voltage variation and ripple on DC tests according to IEC/EN 61000-4-13, -4-14. System Automation A full range of accessories enhance the test systems. Test cabinets, test pistols, adapters and remote control software, simplify interfacing with the EUT. Programmable PSU, EMC hardened for frequencies form 16.7Hz to 400Hz. Frequency PS3-SOFT-EXT complies with IEC / EN 61000-4-14 and -4-28. Service Our committment starts with a quality management system backing up our ISO 17025 accreditation. With the SCS number 146, EMC PARTNER provide accredited calibration and repairs. Our customer support team are at your service! Electricity Meter Test System 15

For further information please do not hesitate to contact EMC PARTNER s representative in your region. You will find a complete list of our representatives and a lot of other useful information on our website: www.emc-partner.com The Headquarters in Switzerland EMC PARTNER AG Baselstrasse 160 CH - 4242 Laufen Switzerland Phone: +41 61 775 20 30 Fax: +41 61 775 20 59 Email: sales@emc-partner.ch Web-Site: www.emc-partner.com Your local representative Information and specifications in this document are an indication of capability only. Technical performance is given in the EMC PARTNER AG Technical specification for the corresponding instruments.version 11.2016. Subject to change without notice. 16 Electricity Meter Test System