Principal, Safe Hospital Services Former VP of Client Services, SiteFM 40+ Years in Healthcare Facilities Management Former Joint Commission Life

Similar documents
ADDENDUM #2 September 12, 2018

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

A/E REVIEW CHECKLIST HVAC

Tri-County Commercial Application Checklist

Residential Construction Checklist Single and Two Family Construction

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

New Multi-Family Buildings & Additions Plan Intake Submittal Checklist. Project Name: Site Address:

APPLICATION FOR COMMERCIAL CONSTRUCTION FIRE AND LIFE SAFETY PLAN REVIEW PROJECT INFORMATION: Project phone: Project Address: City: State: Zip:

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

A. Section includes administrative provisions for coordinating construction operations on Project including, but not limited to, the following:

Commercial Infill Project Guide

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

CHAPTER 5 ARCHITECTURE

BUILDING PLAN REVIEW REQUIREMENTS

TRIBAL BUILDING AND DEVELOPMENT Plan Check Submittal

Summary of Modifications/Changes in this Update

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Knight Abbey ID 439 Contract Design I

Emergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read:

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION PROJECT MANAGEMENT AND COORDINATION

Checklist for Minor Plan Modification

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

FIRE SPRINKLER SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Permits (Submitted to Permit Counter) APPLICATION CHECKLIST

1. Name the horizontal member that rests on the foundation wall to support other wood members.

CITY OF NEWPORT NEWS Department of Codes Compliance 2400 Washington Ave Newport News V A Office Fax

Non-Residential and Multi-Family Plan Check Submittal Requirements

PITKIN COUNTY STANDARDS for ELECTRONIC DRAWINGS and DOCUMENTS SUBMISSION

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

Information for Digital Antenna System (DAS)/ Bi-Directional Amplification (BDA) Systems

BUILDING PLANS. BUILDING DEPARTMENT

VILLAGE OF ALGONQUIN COMMUNITY DEVELOPMENT 2200 Harnish Drive Algonquin, IL Phone (847) Fax (847)

Fire Safety During Construction, Tar Kettles, and Bituminous Melters

SECTION CABLE TRAYS

Architectural Design Process

Residential Room Addition / Remodel Submittal Requirement Checklist

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

CLARK COUNTY FIRE CODE AMENDMENTS

Architecture Firm ID 439 Contract Design I Due: May 4, 2015

SECTION SIGNAGE

OCCUPANT LOAD CALCULATIONS BASEMENT OCCUPANT LOAD FOR CLASS F4 PLACE OF ASSEMBLY WITH MOVABLE SEATS 10 SQ FT / PERSON

Project Affordable Housing Design Rubric

APPENDIX C APPROVAL PROCESS SUBMISSION FORMS. HCJ/LJ/B100841/JR Issue J Nov 17. Appendix C

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS

SECTION MECHANICAL IDENTIFICATION

2012 IMC Performing Commercial Mechanical Inspections

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

RIT CAD Specifications

Installation Guide. SN-LM42 Brilliance Series Photoluminescent Area of Rescue Signs

EMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION

Project Affordable Housing Design Rubric

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

Information package for obtaining a building permit

PLAN SUBMITTAL REQUIREMENTS

B. The designated coverage areas shall include both indoor and outdoor coverage.

Design Deliverables. Summary. A. Expectations for Design Deliverables:

State College Area School District

NEW SINGLE FAMILY HOMES


CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Facility Services Subgroup Preface for Divisions 21` through 28

Using Engineer and Architect Scales

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

CANUTILLO INDEPENDENT SCHOOL DISTRICT 7710 Cap Carter Rd. Canuillo,TX DESIGN CHECKLIST

SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PROJECTS

B. Division-16 Basic Materials and Methods section apply to work specified in this section.

Exhibit A Project Identification. Exhibit B Project Charter / Project Intent. Exhibit C Project Scope. Exhibit C Project Schedule

Residential Plot Plans

The CAD Technician s Role in Office Practice and Procedure

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

IMPORTANT ADDITIONAL CONTRACTOR INFORMATION FROM THE OKLAHOMA TAX COMMISSION

***************************************************************************** DRAFT UFGS- 01 XX XX (FEB 2014)

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

City of Miami Communications Division

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

Booster Amplifiers: Building Codes & New Rules

Element Z General Design Requirements Standards and Other Requirements

Second Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 12/12/ :15 AM

City of Thousand Oaks

INSPECTIONS & PERMITS DEPARTMENT

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D

PMA ONLINE TRAINING. Commercial Drawings. One Hour Continuing Education

Absolute Block. Uncontrolled When Printed Document to be part superseded by GKRT0055 Iss 1 and GKRT0077 Iss 1 (published on 07/09/2013)

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Plan Submittal and Review Checklist

National Association of Women in Construction Education Foundation CADIDESIGNIDRAFTING COMPETITION HIGH SCHOOL STUDENTS

Guide Specification Section Interior Aluminum Doors and Frames

SPARTAN DAY CAMP 4814 FREEDOM RING RD

Fire Plan Symbols And Abbreviations

A. Product Data: For each electrical identification product indicated.

APPLICATION FOR SITE PREPARATION PERMIT

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

Single-Family Dwelling Submittal Requirements

A. Submit properly identified manufacturer's literature before starting work.

Safety (OSHA 10 hour)

Estates Development & Projects

Transcription:

Principal, Safe Hospital Services Former VP of Client Services, SiteFM 40+ Years in Healthcare Facilities Management Former Joint Commission Life Safety Surveyor Former OSHA Voluntary Protection Program (VPP) STAR Worksite Coordinator

At the end of today s program you will be able to discuss: " The importance of accurate drawings " Advantages of the 2000 LSC Edition " Statement of Conditions Requirements " Managing SOC/Life Safety Drawings " Impact on Barrier Management " Impact on Compliance " Impact on Safety

Life Safety Drawings are the basis for the " Life Safety Assessment (LS Chapter) " Statement of Conditions (SOC) " LS.01.01.01 " Barrier Management Program Map " Life Safety Survey Map " LS.02.01.10 " LS.02.01.20

Life Safety Drawings serve as a map to all of the identified elements " Required by The Joint Commission " Potentially requested by CMS (Medicare) " May be different for TJC than for the hospital s license. " Facility should be maintained to the most stringent standard

Inaccurate Life Safety Drawings " Can result in findings by The Joint Commission " Can jeopardize CMS (Medicare) participation status " May cause a failure to maintain required elements " May cause unnecessary work " May cause an unsafe facility

This is the edition of The Life Safety Code that is currently adopted by: " The Joint Commission " The Center for Medicare Service (CMS ) " Most State Health Depts. " Often not the AHJ (Authority Having Jurisdiction)

Provides incentives to be fully sprinkled: " Existing and new hospitals can have non-rated corridor walls " The ceiling can be used in lieu of walls to deck " Existing hospital can have non-rated enclosures " (see table 3A-3)

1 Hr FRRS or nonrated smoke resistant and sprinkled

1 Hr FRRS and sprinkled with ¾ hour rated doors

" Reduction in Fire Dampers requiring 4 year inspection (6 years for healthcare only, and if your state adopts the code). " Reduction in door replacement activity as a result of missing labels or non-rated doors

" There is currently no statement in the accreditation manual to spell out the requirements for SOC drawings " However, The Joint Commission expects drawings to meet minimum standards anyway. " These were published in the Feb 2012 Edition of the Environment of Care News. " In one article of that publication, The Joint Commission noted the following requirements.

Statement of Conditions Drawings Illustrate (provide a legend) each of the following features that exist: " Exterior exit doors " Exit stairs/ramps (exterior or interior) " Smoke-proof enclosures " Horizontal exits " Exit passageways " Fire barriers " Fire/Smoke compartments " Smoke barriers " Linen/trash chutes

Statement of Conditions Drawings Illustrate (provide a legend) each of the following features that exist: " Hazardous Areas (storage, etc) " Suite Boundaries and Square Footage " Shafts " Equivalencies " Waivers " If not fully sprinkled, areas that are and are not sprinkled. " Not required, but a plus PFI locations

" A failure to have accurate drawings will result in a finding under LS.01.01.01, Statement of Conditions " The SOC BBI and related drawings are required for each building that is of a Healthcare or Ambulatory occupancy " The completion of an SOC and related drawings is not required for Business occupancies

Your Drawings Must Be: " Accurate (match field conditions) " Up to date " Reflective of any changes in your facility Your Drawings Should Also: " leverage 2000 NFPA 101 LSC " Be readily accessible

Your Drawings Ideally Should Be: " Readily accessible " Easy to find " Widely viewable " Flexible " Affordable " Utilized Regularly

Life Safety Drawings Sample Policy POLICY Accurate Life Safety (LS) Drawings must be available at all times and provided to the Life Safety surveyor during the building tour. They are the basis for the Life Safety Assessment, Statement of Conditions, Life Safety Building Maintenance Plan and the Life Safety Survey Map. Life Safety Drawings serve as a map to The Joint Commission (TJC), Centers for Medicare and Medicaid Services (CMS), State Health Departments, and by the Authority Having Jurisdiction (AHJ). PROCEDURE The ideal situation would be to have a professionally prepared set of Life Safety Drawings of your Organization. If not, you can use a rough sketch, (representative drawings), or floor plans for each story occupied by your organization. Life Safety Drawings must address the following topics: A legend that clearly identifies features of fire safety Areas of the building that are fully sprinkled (if the building is partially sprinklered) Location of all Exterior exit doors Locations of all hazardous storage areas Locations of all rated barriers (exit stairs/ramps, horizontal exits and exit passageways) Locations of all smoke barriers Suite boundaries, including the size of the identified suites both sleeping (max 5000 sq ft) and non-sleeping (max 10,000 sq ft) Locations of designated smoke Compartments Locations of chutes and shafts Wet locations Location of any approved equivalencies or waivers TJC requires hospitals to define who within your organization is qualified to prepare your SOC. Although there may be many individuals who have a general understanding of the use of NFPA 101 to adequately perform periodic updates of general code-related issues, those individuals may not be qualified to perform a comprehensive evaluation of you building s level of code compliance. The preparer of the esocs name and/or organization should be listed in the Other Information section of the Basic Building Information (BBI). While TJC does not specify where LS drawings should be located, the engineering department is a logical place to keep such documents. The location of the LS drawings should also be in the Other Information section of the BBI.

Drawings may range from basic to complex depending on the needs of

Required SOC Layers " Serve as a guide to the surveyor s building tour " Serve as a guide to maintenance operations " Serve the Code Red plan to identify safe refuge " Supports horizontal evacuation (staying indoors)

SOC Plans for Improvement (PFI) By adding a PFI layer, the organization can easily show a surveyor where their PFI s are.

Provides a way to accurately assure appropriate walls are inspected and maintained " Assure proper inspection of smoke and fire barriers above ceiling " Corridor walls can be maintained to the ceiling if the ceiling can be maintained to resist the passage of smoke (check with Local AHJ first, not permissible under IBC) " Doors may not require rating. " But, if a door was installed to latch, latching must be maintained

Do the right things at the right time " If a wall is not needed as a barrier or partition, then it will not need to be maintained (above the ceiling) " Helps assure inclusion of Hazardous Locations " Rated walls will be identified for use of UL Rated Systems for Penetrations and Construction Joints

" Map Utility Main Cut-offs " Major Electrical Disconnects " Main and Zone Medical Gas Valves " Sprinkler and Domestic water Shut-off valves " Security Components

To have a fire-safe building " Have and use accurate, reliable drawings " Manage an effective Barrier Management Program " Manage Fire Safety Equipment " Manage an Above Ceiling Permit process " Conduct Fire Drills as required " Use ILSM as needed

Life Safety Drawings/Plans: " A required component of the SOC " The basis for the Life Safety Program " Essential for Barrier Management " Improve communication with techs and contractors

Start with what you have " Make copies of best existing LS drawing " Make copies of project drawings showing changes in wall layout " Refer to evacuation maps, SOC drawings, possibly other resources " Leverage the advantages of the Code

Tour the building " Start at the top and work downward " Open the ceiling and inspect the walls " Does wall rating/construction/door rating align with drawings? " Do wall stencils align with drawings? " Tour building below ceiling " Observe changes in space utilization " Observe new Hazardous Areas

Mark up existing drawings " Use consistent markup standards " Color code wall types " Put notes around the outside, with a line or arrow pointing to the location of the issue. " Make lengthy notes on back or separate notepad

Compare to Code " Compare building to the 2000 Edition (2012) " Leverage code permitted advantages " These are SOC drawings, not for filing with the State " Maintain the building to original requirements

" It is possible to work with PDFs with a low cost application such as Adobe Acrobat Pro or Power Point " However, it is difficult to accurately determine square footage for smoke compartments and suites. " Working in CAD permits accurate calculation of square footage for such things as smoke compartments and suites.

" Whether In-house or through outsourced CAD services, the following process is recommended. " It is essential that the person or persons touring the building have a strong understanding of Life Safety Code for the occupancies of their building(s)

The Drawing Update Process " Know the codes or hire expertise " Tour the building and; " Mark up a copy of old drawings " Mark up a clean set " Submit for CAD work " Review and mark up first drafts " Submit for final CAD work " Print color-code drawings

Start with whatever you have

Tour the building and mark it up

Begin with a clean floor plan

Add Doors Showing Direction of Swing

Show Egress Corridors and Exit Discharge Points

Add Occupancy Separation and Smoke/Fire Barriers

Show Hazardous Locations and Suites (with square footage)

Show Smoke Compartments with Square Footage

Exit Signs, Egress Fixtures and Fire Alarm/ Sprinkler Devices Can Useful Layers

The Goal: Life Safety Drawings that are accurate and easy to understand

Tom Zahorsky CHFM, CHSP-FSM Principal Safe Hospital Services Email: tomz@safehospitalservices.com Phone: 281-362-1686 Mobile: 832-687-8671