BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted

Similar documents
SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

SRC-21x Series Climate Controllers with BACnet MS/TP

SRC-110 Series Zone Controllers with Modbus RTU

BACnet Protocol Implementation Conformance Statement

Electronic pressure-independent characterised control valve with energy monitoring

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

BAS Integration Manual

USB BACNET COMMUNICATION OPTION MANUAL

SRC-200 Series Climate Controllers with BACnet MS/TP

Nemo D4-L+ BACNET COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement. Date: March, 30 th 2012 Vendor Name:

USB BACNET COMMUNICATION OPTION MANUAL

IF96014 BACnet COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement

Electronic pressure-independent characterised control valve with energy monitoring

BACnet Protocol Implementation Conformance Statement

BACnet Integration Manual

Communicative heating and cooling controller, BACnet MS/TP UB200. Summary

EPC3000 Programmable Controller

PIR Ready SE7200, SE7300 & SER7300 Series

PIR Ready VT72xx & VT(R) 73xx Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications

MINI and MIX Series I/O modules

SKDESC-xB Series Electronic Steam Controller

Belimo Gateway MP to BACnet MS/TP - UK24BAC

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665

BACnet communication module for TCX2: AEX-BAC

CALEC ST II BACnet MS/TP

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682

RF-RXS-B SonNet Wireless Receiver BACnet IP

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor

Position Indicator with/without Limit Values

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

VAC V AC/DC, +/-10%, 45-65Hz Hz VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER

1 Digital input (24Vac or dry contact) Inputs

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

EY-EM 527: Remote I/O module, ecolink527

EVCB14NIT4X. BACnet Communication Module User Guide

User Guide. EVCB14NIT4X-V410-BACnet Guide-EUA docx

IP I/O Communication Module Specification and Installation Instructions

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Instruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

08/07/2015

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

EY-EM 522, 523: Remote I/O module, ecolink522, 523

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

BACnet communication module for TCX2: AEX-BAC

ENERGY-0-RS. Energy Meter. User manual

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

CURRENT/FREQUENCY CONVERTER S 104

Spring Return DuraDrive Proportional Actuator

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

Energy Management Energy Meter Type EM340

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Lighting Stryker BACnet CLB6438S Configurable Lighting Controller

Ramp/Soak Temperature Controller REX-P250

Energy Management Energy Analyzer Type EM111

Brief description. Type overview

Gas Fired Humidifier SKG Series

Energy Management Energy Meter Type EM110

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management Energy Analyzer Type EM112

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications

02/11/2015

Type Nominal voltage (V) Code HSV V

08/07/2015

Uni-Mux XQL Multi-Channel Data Acquisition Module

Modbus communication module for TCX2: AEX-MOD

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

CompoBus/D-type Digital Controller

02/11/2015

s Climatix extension module 26 I/Os POL985.00/XXX

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Bulletin B1243: RIBTW24B-BCAI RIBMNW24B-BCAI

Non-Spring Return DuraDrive Modulating Actuator

Industrial Modbus I/O Modules

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Electro Controls. Input-Output Modules WattsIndustries.co.uk

02/11/2015

05/09/2012

02/11/2015

RSMFX-2R MULTIFUNCTIONAL

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Acceleration sensors With relay output for limit monitoring Analog / CANopen

JENEsys Edge 534 N4 WIRING INSTALLATION GUIDE

HD 48V01T... HD 4977T...

Custom "Compact" range with display CD20 Custom Part number

SOLO Temperature Controllers 1/4 DIN

Transcription:

Product sheet MOD Type BAC-IO9 BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted BAC-IO9 and BAC-IO9-AI have been designed to be a compact wall mounted BACnet MS/TP input and output modules. The module has 2 volt-free digital inputs for measurements e.g. for windows, occupancy sensors and so on. The module has 2 digital outputs, Vac triacs switching the plant items on/off. The IO9 modules has 2 inputs for measuring NTC0 temperature, resistive measurements (e.g. light level) or volt-free on/off signals. The IO9-AI models have 2 inputs for measuring 0..0Vdc signals. The three analogue 0..0Vdc outputs complete the compact IO-modules. With the analogue outputs it is possible to control zone valves and other modulating plant equipment. The modules support BACnet MS/TP communications with most commonly used baud rates and parity settings. The module also supports BACnet device and object discovery allowing fast and efficient programming. Model Type Model Description BAC-IO9 BACnet MS/TP Digital Input / Output Module, 2DI, 2DO, 2I, 3AO BAC-IO9-AI BACnet MS/TP Digital Input / Output Module, 2DI, 2DO, 2AI, 3AO Technical Data Power Supply Power supply Vac/dc -0%/+5% Signal Outputs Analogue Outputs 3 x 0..0V < 5mA; 00k min impedance for % accuracy Digital Outputs 2 x Vac Triacs; 2A maximum; requires Vac Power Supply Signal Inputs esistive Inputs (MOD-IO9) 2 x Universal NTC0/esistive/Digital Inputs, 0..50kOhms (NTC0/Volt-Free Digital default, configurable via SW-DCT-USB tool to resistive mode) Voltage Inputs (MOD-IO9-AI) 2 x 0..0Vdc Inputs Digital Inputs 2 x Volt-Free Contact, Impedance <KOhm Pulse Counting: Max 25Hz, Min Pulse Length 20mA (Volatile) Communication BACnet Communications Protocol BACnet MS/TP Interface S45; maximum 63 devices MAC Addressing 0..63 via a bit switch; 0..7 via tool / network Communication 9k6/9k2/3k4/76k Baud; Parity /Even/Odd, or 2 Stop Bits (baud rate adjustable through bit switch) Connections Terminal Connections Solid and Stranded Cable; 55 Angle for Wiring Maximum Size: 0.05 to.5mm 2 (EN ISO) / 4 to 30 AWG (UL) ising Clamp: Size 2.5 x.9mm Environmental Conditions Operating Temperature 0 C...+50 C (..22 F) Humidity 0...95%rh (non-cond.) Storage PS SN.4.55 - /

Temperature Humidity -30 C...+70 C (-22..5 F) 0...95%rh (non-cond.) Standards CE Conformity CE Directive 2004/0/EY EN6000-6-3: 200 (Generic Emission) EN6000-6-: 200 (Generic Immunity). Degree of Protection IP20 Housing Housing Material ABS Plastics, Self Extinguishing Mounting Wall or Junction Box Mounting, AL900 Pure White Dimensions W6 x H20 x D29mm Weight 0g Wiring Terminals Vac elay Vac elay DO DO2 Digital Output, Vac Triac Digital Output 2, Vac Triac BAC-IO9 Vac/dc 0 V G Go Vac/dc Supply Y Analogue Output, 0..0Vdc Y2 Analogue Output 2, 0..0Vdc Y3 Analogue Output 3, 0..0Vdc Go BIT SWITCH Network A+ S45 (BACnet MS/TP) B- S45 (BACnet MS/TP) Network Address Bit ate Bit ate 2 Go I DI I2 DI2 NTC0/esistive Input 0..50kOhms/Digital Input 3 (BAC-IO9) 0..0Vdc Input (BAC-IO9-AI) Digital Input, Volt-Free NTC0/esistive Input 2 0..50kOhms/ Digital Input 4 (BAC-IO9) 0..0Vdc Input 2 (BAC-IO9-AI) Digital Input 2, Volt-Free DO Digital Output; Vac Triac Switching to 0V; max. 2A DO2 Digital Output; Vac Triac Switching to 0V; max. 2A G Vac/dc Power Supply G0 Y 0..0Vdc Analogue Output Y2 0..0Vdc Analogue Output Y3 0..0Vdc Analogue Output G0 A+ S45 A+ Connection (BACnet) B- S45 B- Connection (BACnet) G0 I IO9: NTC0/esistive Input 0..50kOhms/Volt-Free Digital IO9-AI: 0..0Vdc DI Digital Input; Volt-Free, Max 25Hz, Min Pulse Length 20mS I2 IO9: NTC0/esistive Input 0..50kOhms/Volt-Free Digital IO9-AI: 0..0Vdc DI2 Digital Input; Volt-Free, Max 25Hz, Min Pulse Length 20mS Digital Input Pulse Counting Digital Inputs can be used for pulse counting up to 25Hz, minimum pulse length 20mS. The pulse count is stored in a dedicated register and can be read over the network. It is possible to write to this register to reset the value. PS SN.4-2/

Universal NTC0/ esistive/digital Inputs (BAC-IO9) Analogue Inputs (BAC-IO9-AI) Setting Up BACnet Address and Baud ate NOTE: The pulse count value is not battery backed, and therefore the network master is required to manage the data synchronisation in case of power failure. The universal inputs can be configured to operate as NCT0/Digital Volt-Free inputs or esistive Inputs. As default the inputs are configured as NTC0/Digital Volt-Free. The maximum measurement range is -0 C to 00 C (-40 F to 22 F). The NTC0/resistive configuration is changed via the Configuration Software using the USB to IO-Module cable. The digital volt-free mode is automatically activated, and a separate BACnet Binary Input objects are available to read the status. The BAC-IO9-AI has 2 x 0..0Vdc inputs. The current status can be read over the BACnet communication network. The BACnet address and the baud rate is normally set through the bit switch. It is also possible to set the address and baud rate over the configuration tool or over the BACnet communication network. NOTE: The new settings are activated automatically after approx 5 seconds if the bit switch positions have not been moved. In this case the controller reset is applied to activate the new settings. SETTING TANSMITTE BAUD ATE BAUD ATE BAUD ATE BIT SWITCH 7600 3400 Network Address Bit ate Bit ate 2 BAUD ATE 9200 BAUD ATE 9600 / NETWOK SETTING TANSMITTE BACNET MAC ID The BACnet MAC ID is set by using bith switches BIT SWITCH to 6 using binary decoding. Each bitswitch represents the binary value and the address is set by the combination of bit switches. Few examples: Network Address Bit ate Bit ate 2 BACNET MAC ID 2 BACNET MAC ID 9 Note: When the baud rate set 9600 via the bit switch it is possible to configure the baud rate via network / tool. Note: To activate the change the transmitter requires power cycle, or software reset via the tool. Note: If all address bit switches are set, then the BACnet ID can be set over the BACnet or through configuration tool. BACnet Interoperability Building Blocks Supported (Annex K) Application Service Initiate Execute BIBB eadproperty Yes DS-P-B eadpropertymultiple Yes DS-PM-B WriteProperty Yes DS-WP-B einitializedevice Yes Who-Is Yes DM-DDB-B I-Am Yes Who-Has Yes DM-DOB-B I-Have Yes DeviceCommunicationControl Yes DM-DCC-B BACnet Standard Types Supported No dynamic Creation or Deletion supported. s, and object instances, are assigned to fixed f unctions within the proprietary control application of the product as follows: Number Of Instance Assignments Instances Device Analog Input 7 AI(0) Not Assigned AI() Not Assigned AI(2) Not Assigned AI(3) NTC0/I/AI AI(4) NTC0/I2/AI2 AI(5) Not Assigned AI(6) Not Assigned Analog Outputs 3 AO(0) Y Output AO() Y2 Output AO(2) Y3 Output Analogue Value 6 AV(0) Not Assigned AV() Not Assigned AV(2) Not Assigned AV(3) Not Assigned AV(4) DI Pulse Count AV(5) DI2 Pulse Count PS SN.4-3/

Number Of Instances Instance Assignments Binary Input 3 BI(0) DI input BI() DI2 Input BI(2) Not Assigned BI(3) Not Assigned BI(4) Not Assigned BI(5) Not Assigned BI(6) Not Assigned BI(7) DI3 input (Universal I Input) - BAC-IO9 BI() DI4 Input (Universal I2 Input) - BAC-IO9 Binary Output 2 BO(0) DO Output BO() DO2 Output Device (equired ) Property Name /ID Attributes ange Default Identifier /W MAC_Address + 65000 Name /W Characters Max Concatenation of product type and MAC address i.e. "BIO_00" Type System Status STATUS_OPEATIAL Vensor Name SyxthSense Vendor Indetifier 65 Model Name UD Protocol Version Protocol evision 0 Max APDU Length 40 Segmentation Support No APDU Timeout 3000 ms Number APDu etries 3 MaxMaster 27 Max_Info_Frames Database evision 0 PS SN.4-4/

Analogue Input s equired Property Name /ID Attributes ange Default Identifier Name AI(0) Not Assigned AI() Not Assigned AI(2) Not Assigned AI(3) NTC0 / I/ AI AI(4) NTC0 / I2/ AI2 AI(5) Not Assigned AI(6) Not Assigned Type 0 Present Value /W AI(0): Not Assigned AI(): Not Assigned AI(2): Not Assigned AI(3): -40..50000 AI(4): -40..50000 AI(5): Not Assigned AI(6): Not Assigned Status Flag Out-Of-Service /W FALSE Units AI(0): Not Assigned AI(): Not Assigned AI(2): Not Assigned AI(3): UNITS_OHMS AI(4): UNITS_OHMS AI(5): Not Assigned AI(6): Not Assigned Analogue Output s equired Property Name /ID Attributes ange Default Identifier Name AO(0) = Y AO() = Y2 AO(2) = Y3 Type Present Value /W 0..00 Status Flag Out-Of-Service /W FALSE Units UNITS_PECENT PS SN.4-5/

Analogue Value s equired Property Name /ID Attributes ange Default Identifier Name AV(0) Not Assigned AV() Not Assigned AV(2) Not Assigned AV(3) Not Assigned AV(4) - DI Pulse Count AV(5) - DI2 Pulse Count Type 2 Present Value /W Status Flag Out-Of-Service /W FALSE Units AV(4) = NO_UNITS AV(5) = NO_UNITS Priority Array elinquish Default /W AV(0) = Not Assigned AV() = Not Assigned AV(2) = Not Assigned AV(3) = Not Assigned AV(4) = 0 AV(5) = 0 Binary Input s equired Property Name /ID Attributes ange Default Identifier Name BI(0) = DI BI() = DI2 BI(2) = Not Assigned BI(3) = Not Assigned BI(4) = Not Assigned BI(5) = Not Assigned BI(6) = Not Assigned BI(7) = DI3 (I) - BAC-IO9 BI() = DI4 (I2) - BAC-IO9 Type 3 Present Value /W 0.. Status Flags Out-Of-Service /W FALSE Polarity /W POLAITY_NOMAL Active Text "on" Inactive Text "off" PS SN.4-6/

Binary Output s equired Property Name /ID Attributes ange Default Identifier Name BO(0) = DO BO() = DO2 Type 4 Present Value /W 0.. Status Flags Out-Of-Service /W FALSE Polarity /W POLAITY_NOMAL Priority Array elinquish Default /W BINAY_INACTIVE Active Text "on" Inactive Text "off" Types No dynamic Creation or Deletion supported App_Config Application Configuration Number Of Instances Instance Assignments Provides a container for all the proprietary application specific properties. equired Property Name /ID Attributes ange Default Identifier MAC_Address + 65000 Name "App_Config" Type 2 Property ID Description BACnet Data Type ange 3000 Firmware Unsigned ead Only Version 40050 MAC Address Unsigned 0..255 4005 Baud ate Unsigned 0 = 9600 (Default) = 9200 2 = 3400 3 = 57600 40067 Hold On Delay Setting for Digital Input Unsigned..7200 Seconds (Default 0s) 4006 Hold On Delay Setting for Digital Input 2 Unsigned..7200 Seconds (Default 0s) 4000 Force eset Unsigned 0 = Normal = Force eset 400 Non Volatile Memory Update 4003 Force Factory Defaults Unsigned Unsigned 0 = Normal = Update 0 = Normal = Force Defaults PS SN.4-7/

4004 Force 0..0V Output Calibration outine Unsigned 0 = Normal = Force Calibration Dimensions Wall Box Screw Hole Locations 79 64 5 20.50 4 60 5 6 2.7 PS SN.4 - /