5500A. Multi-Product Calibrator. Operator Reference Guide. PN December, 1994

Similar documents
5700A/5720A Series II Multi-Function Calibrator

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator

5500A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications

5520A. Getting Started. Multi-Product Calibrator

5522A. Getting Started. Multi-Product Calibrator

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

M-140 Multifunction Calibrator. Operation manual

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

5520A. Operators Manual. PQ Option

5820A. Service Manual. Oscilloscope Calibrator

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

HP 33120A Function Generator / Arbitrary Waveform Generator

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

LAB I. INTRODUCTION TO LAB EQUIPMENT

5502A Multi-Product Calibrator. Extended specifications

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

BENCH METER Model>9803. Wavecom Instruments

5080A Multi-Product Calibrator

5522A Multi-Product Calibrator Extended specifications

Introduction to basic laboratory instruments

Fluke 125. Getting Started. Industrial ScopeMeter

79/26 Series III Multimeter

Agilent 33250A 80 MHz Function / Arbitrary Waveform Generator. User s Guide

Fluke 123/124 Industrial ScopeMeter

Model Multimeter Specifications ABSOLUTE ACCURACY TYPICAL ACCURACIES 2002 SPECIFIED CALIBRATION INTERVALS

5500A. Service Manual. Multi-Product Calibrator

LAB II. INTRODUCTION TO LAB EQUIPMENT

5820A. Service Manual. Oscilloscope Calibrator

MC133C/133Ci. Electric Power/Energy Calibrator. Operation manual

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

5 ½ Bench Digital Multimeter

DVM1190 DIGITAL MULTIMETER

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

400Amp True RMS AC/DC Clamp Meter Model EX613

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

4 ½ Digit and 50,000 Count Bench Multimeters USER MANUAL

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

USER'S MANUAL DMR-6700

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

PXIe Contents. Required Software CALIBRATION PROCEDURE

DM-45 Digital Multimeter

Operation manual. PeakTech 4095 PeakTech Graphical Bench-Type Multimeter

Introduction to Basic Laboratory Instruments

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Agilent E3633A and E3634A DC Power Supplies

1-1 Introducing the 50,000 Count Dual Display Multimeter

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Model 2015 THD Multimeter Service Manual

LAB I. INTRODUCTION TO LAB EQUIPMENT

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

APPA 300 Series. The Most User-Friendly High Performance Multimeter

The Meter Structure The Figure 2-1 shows the Meter structure.

1.General instructions Specifications Description...7

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

COM-POWER OPERATION MANUAL ACS W

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Agilent 33210A 10 MHz Function / Arbitrary Waveform Generator. User s Guide

114, 115, and 117. True-rms Multimeters. Users Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual

7526A. Calibration Manual. Precision Process Calibrator

M 140i. Multifunction Calibrator. Operation Manual

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model & MultiScope TM

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

OPERATOR S INSTRUCTION MANUAL

Arbitrary/Function Waveform Generators 4075B Series

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Analog Technologies. Multimeter 15B and17b

Agilent 33220A. 20 MHz Waveform Generator. User's Guide. Agilent Technologies

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

SDM3045X Digital Multimeter. DataSheet

Model MHz Arbitrary Waveform / Function Generator

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Installation Guide. Agilent Technologies E4428C/38C ESG Signal Generators. Manufacturing Part Number: E Printed in USA October 2012

MW3105 DIGITAL CLAMP MULTIMETER

7526A. Users Manual. Precision Process Calibrator

SDG1000X Series Function/Arbitrary Waveform Generator. Quick Start QS0201X-E01A

200Amp AC Clamp Meter + NCV Model MA250

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

Analog Technologies. Multimeter 115C and 117C

True-RMS Digital Multimeter User Manual

Not for Reproduction

AM

Model 6517B Electrometer / High Resistance Meter Specifications

Manual Supplement Fluke Corporation. All rights reserved. Printed in U.S.A. x

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Transcription:

5500A Multi-Product Calibrator Operator Reference Guide PN 945097 December, 1994 1994 Fluke Corporation, Inc. All rights reserved. Printed in U.S.A.

Table of Contents Replacing the Fuse... 4 Selecting Line Voltage... 5 Front Panel Features... 5 Rear Panel Features... 10 Setup Menu... 12 Instrument Setup Menu... 12 Selecting an External Amplifier... 12 Utility Functions Menu... 13 Format EEPROM Menu... 13 Zeroing the Calibrator... 15 Operate and Standby... 16 Connecting the Calibrator to a UUT... 16 When to Use EARTH... 16 Four-Wire versus Two-Wire Connections... 16 Cable Connections... 17 Setting the Output... 20 Setting DC Voltage Output... 20 Setting AC Voltage Output... 21 Setting DC Current Output... 23 Setting AC Current Output... 24 Setting DC Power Output... 25 Setting AC Power Output... 27 Setting a Dual DC Voltage Output... 29 Setting a Dual AC Voltage Output... 30 Setting Resistance Output... 33 Setting Capacitance Output... 34 Setting Temperature Simulation (Thermocouple)... 35 Setting Temperature Simulation (RTD)... 37 Measuring Thermocouple Temperatures... 38 1

Waveform Types... 41 Sinewave... 41 Trianglewave... 41 Squarewave... 42 Truncated Sinewave... 42 Setting Harmonics... 43 Adjusting the Phase... 44 Entering a Phase Angle... 45 Entering a Power Factor... 45 Entering a DC Offset... 46 Using the 5725A Amplifier... 47 5725A Amplifier Output... 48 Editing and Error Output Settings... 49 Editing the Output Setting... 49 Displaying the Output Error... 50 Using Multiply and Divide... 50 Setting Output Limits... 50 Setting Voltage and Current Limits... 50 2

Safety Symbols WARNING Risk of electric shock. Refer to the manual (see the Index for references). GROUND Ground terminal to chassis (earth). Attention Refer to the manual (see the Index for references). This symbol indicates that information about usage of a feature is contained in the manual. This symbol appears on the rear panel ground terminal and by the fuse compartment. AC Power Source The instrument is intended to operate from an ac power source that will not apply more than 264V ac rms between the supply conductors or between either supply conductor and ground. Use the Proper Fuse For fuse replacement use: 110 or 120 V operation, 2.5 ampere/250 volt time delay; 220 or 240 V operation, 1.25 ampere/250 volt time delay. Grounding the instrument The enclosure must be grounded through the grounding conductor of the power cord, or through the rear panel ground binding post. Use the Proper Power Cord Use only the power cord and connector appropriate for the voltage and plug configuration in your country. Use only a power cord that is in good condition. Refer power cord and connector changes to qualified service personnel. 3

120 240 120 CAUTION Verify applied voltage to the UUT does not exceed the UUT insulation rating. Replacing the Fuse Disconnect line power. Follow the figure below for fuse replacement. MAINS SUPPLY 100V / 120V 220V / 240V FUSE T2.5A 250V (SB) T1.25A 250V (SB) CAUTION FOR FIRE PROTECTION REPLACE ONLY WITH A 250V FUSE OF INDICATED RATING 47Hz / 63Hz 300VA LINE VOLTAGE INDICATOR CHANGING LINE FUSE 0V (SB) CHANGING LINE VOLTAGE 4

1000V RMS V,, RTD 20V PK A, -SENSE, AUX V 20V RMS 20V PK 200V PK µ n p dbm W sec F Selecting Line Voltage There are four line voltage settings: 100V, 120V, 200V, and 240V (47 to 63 Hz). To check the setting, note the voltage setting visible through the window in the power line fuse compartment cover. To change the line voltage setting, follow the figure above for Changing Line Voltage. Front Panel Features Front panel features include all controls, displays, indicators, and terminals. 1 3 4 5 6 7 8 9 2 5500A CALIBRATOR NORMAL AUX SCOPE STBY PREV OPR EARTH SCOPE BOOST MENU HI LO 1V PK TRIG OUT 7 8 9 4 5 6 EDIT m V Hz SETUP RESET FIELD k A C NEW CE REF 1 2 3 M F MEAS TC TRIG OUT TC +/ 0 SHIFT ENTER MULT x DIV POWER I O 1 Output Display Two-line backlit LCD showing output amplitudes, frequency and calibrator status. 2 Control Display Multipurpose backlit LCD used for displaying data entries, UUT error adjustments, softkey labels, phase angles, watts, power factors, and other prompts and messages. 5

3 Y Places the 5500A in the standby mode. The NORMAL and AUX output terminals are internally disconnected from the 5500A. 4 O Places the 5500A in the operate mode and lights the indicator on the key. 5 Z Opens/closes a connection between the NORMAL LO terminal and earth ground, and lights the indicator on the key. 6 a Enables or disables the ScopeCal option if it is present. An annunciator on the key indicates when the option is enabled. 7 B Enables or disables output from an amplifier. An annunciator on the key indicates when the 5725A is being used. 8 P Recalls the previous set of menu choices. Each press of this key backs up one level of the menu tree. 9 Softkeys Softkeys are identified by labels on the Control Display directly above each key. 6

1000V RMS 1V PK 20V PK 20V RMS 20V PK 200V PK 10 11 12 13 14 5500A CALIBRATOR NORMAL AUX SCOPE STBY PREV OPR EARTH SCOPE BOOST MENU TC HI LO TRIG OUT 7 8 9 4 5 6 1 2 3 +/ 0 µ dbm sec m V Hz SETUP RESET EDIT FIELD n p k M SHIFT W A ENTER F C F NEW REF MEAS TC MULT x CE TRIG OUT DIV POWER I O 21 20 19 18 17 16 15 10 N Active during error mode operation, and establishes the present output value as a new reference for meter error computation. 11 S Displays the setup menu in the control display. Setup options can be selected using the softkeys. 12 R Aborts the current operating state of the 5500A and returns it to the power-up default state, except during remote control. 13 G Clears a partially completed keypad entry from the Control Display. 7

14 L e W Provide step adjustment of the output magnitude by selecting digits, provides means of adjustment and selection. 15 Turns the power on and off. The switch is a latching push-push type. 16 T Sets the external trigger when in the Scope mode. 17 D Changes the output to one tenth the reference value (not necessarily the present output value). 18 X Changes the output to ten times the reference value (not necessarily the present output value). 19 U Enables the TC (Thermocouple) input connection and causes the 5500A to compute a temperature based on the input. 20 Output Units Keys Determine the function of the 5500A. Some keys have a second unit if the SHIFT key is pressed just before the units key. 21 c j d Multiplier Keys Select output value multipliers. Some keys have a second function using SHIFT. 8

1000V RMS V,, RTD 20V PK A, -SENSE, AUX V 20V RMS 20V PK 200V PK µ n p dbm W sec F 5500A CALIBRATOR NORMAL AUX SCOPE STBY PREV OPR EARTH SCOPE BOOST MENU HI LO 1V PK TRIG OUT 7 8 9 4 5 6 EDIT m V Hz SETUP RESET FIELD k A C NEW CE REF 1 2 3 M F MEAS TC TRIG OUT TC +/ 0 SHIFT ENTER MULT x DIV POWER I O 30 29 28 27 26 25 24 23 22 22 E Loads a newly entered output value shown on the Control Display into the 5500A, which appears on the Output Display. 23 b Selects alternate functions of the units keys and alternate multipliers of the multiplier keys. 24 Numeric Keypad Used to enter the digits of the output amplitude and frequency 25 I Changes the polarity of the output for dc voltage or dc current functions. 26 Used to trigger the oscilloscope during oscilloscope calibration. 27 Used for outputs during oscilloscope calibration. 28 Used for thermocouple simulation during temperature meter calibration, and thermocouple measurements. 9

MAINS SUPPLY 100V / 120V 220V / 240V FUSE T2.5A 250V (SB) T1.25A 250V (SB) CAUTION FOR FIRE PROTECTION REPLACE ONLY WITH A 250V FUSE OF INDICATED RATING 47Hz / 63Hz 300VA TO CLEAN FILTER REMOVE FROM INSTRUMENT AND FLUSH WITH SOAPY WATER WARNING GROUNDING CONNECTOR IN POWER CORD MUST BE CONNECTED TO ENSURE PROTECTION FROM ELECTRIC SHOCK FLUKE CORPORATION MADE IN USA PATENTS PENDING NO INTERNAL USER SERVICEABLE PARTS. REFER SERVICE TO QUALIFIED SERVICE PERSONNEL 29 AUX Used for ac and dc current outputs, the second voltage output in dual voltage modes, and ohms sense for 2-wire and 4-wire compensated resistance and capacitance measurements, and RTD simulation. 30 NORMAL Used for ac and dc voltage, ohms and capacitance sourcing, and Resistance Temperature Detector (RTD) simulation. Rear Panel Features 1 2 3 4 NORMAL ENABLE CALIBRATION SERIAL 2 TO UUT IEEE-488 SERIAL 1 FROM HOST BOOST AMPLIFIER CHASSIS GROUND 8 7 6 5 1 Fan Filter Covers the air intake to keep dust and debris out of the chassis air baffles. 2 CALIBRATION SWITCH Used to write enable/disable nonvolatile memory that stores calibration constants. 3 SERIAL 2 TO UUT Connector used for transmitting/receiving serial data between the 5500A and a Unit Under Test (UUT). 4 SERIAL 1 FROM HOST Connector used for remote control of the 5500A with a host, printer, or terminal. 10

5 BOOST AMPLIFIER Connector provides the analog and digital interface for the Fluke 5725A Amplifier. 6 IEEE-488 Connector is a standard parallel interface for operating the 5500A in remote control on the IEEE-488 bus. 7 WARNING To avoid shock hazard, connect the factory supplied threeconductor line power cord to a properly grounded power outlet. Do not use a two-conductor adapter or extension cord; this will break the protective ground connection. Use the rear-panel ground terminal for a protective grounding wire if there is any question as to instrument earth grounding. CHASSIS GROUND Binding post is internally grounded to the chassis. 8 AC Power Input Module Provides a grounded three-prong connector that accepts the line power cord, a switch mechanism to select the operating line voltage, and a line power fuse. 11

Setup Menu Press S for the SETUP menu. CAL SHOW SPECS INSTMT SETUP UTILITY FUNCTNS Instrument Setup Menu Press the INSTMT SETUP softkey in the Setup to open the Instrument Setup Menu. TMP STD its-90 OUTPUT SETUP DISPLAY SETUP REMOTE SETUP its-90 ipts-68 Selecting an External Amplifier Press OUTPUT SETUP softkey in Instrument Setup Menu to open menu for SOURCE PREFRENCE softkey. RTD TYPE pt385 TC TYPE K SOURCE PREFRENCE 5500 OUTPUT LIMITS 5500 5725 12

Utility Functions Menu Press the UTILITY FUNCTNS softkey in the Instrument setup Menu to open the utility menus. SELF TEST FORMAT NV MEM INSTMT CONFIG Format EEPROM Menu CAUTION Use with extreme care. The format nonvolatile memory menu softkeys permanently erase calibration constants. Pressing ALL or CAL invalidates the state of calibration of the 5500A. Pressing FORMAT NV MEM in the utility functions menu opens the following: ALL Format NV Memo CAL SETUP The softkeys in this menu require the rear panel CALIBRATION switch to be in the ENABLE position, except for SETUP. ALL Replaces the entire contents of the EEPROM with factory defaults. CAL Replaces all calibration constants with factory defaults. SETUP Replaces the setup parameters with factory defaults (see Defaults table). 13

Factory Defaults for SETUP Features Temperature Standard Host Connection its-90 gpib (IEEE-488) GPIB Port Address 4 Serial Ports EOL (end of line) 8 bits, 1 stop bit, xon/xoff, parity none, 9600 baud, wait 30 sec. CRLF EOF (end of file) 012,000 Remote I/F term Display Contrast* level 7,7 Display Brightness* level 1,0 RTD Power Up Default Type Thermocouple Power Up Default Type pt385 K Source Preference 5500 Current Limits Voltage Limits +11 A +1000 V Remote commands SRQSTR SRQ: %02x %02x %04x %04x *PUD string cleared * Output Display and Control Display, respectively. There are 8 levels: 0,1,2,3,4,5,6,7. 14

Zeroing the Calibrator To meet the specifications, zeroing is required every 7 days, or when the 5500A Calibrator ambient temperature changes by more than 5 C. Choose from complete instrument zeroing (ZERO) or ohms-only zeroing (OHMS ZERO). 1. Turn on Calibrator and warmup (30 minutes). 2. Press R key. 3. Install copper short circuit in TC connector (complete instrument zeroing only). 4. Press S key, opening setup menu. CAL SHOW SPECS INSTMT SETUP UTILITY FUNCTNS 5. Press CAL softkey in setup menu. CAL CAL DATES CAL REPORTS 6. Press CAL softkey in calibration menu. 5500A CAL OHMS ZERO ZERO ERR ACT backup 7. Press ZERO softkey for complete instrument zeroing or OHMS ZERO for ohms-only zeroing. After zeroing routine is complete (several minutes), press R. 15

Operate and Standby To enable the operate mode, press O. To place the calibrator in standby, press Y. The calibrator goes into the standby if: The R key is pressed. A voltage 33V is selected when the previous output voltage was less than 33V. Function changed. Output location is changed. Overload condition is detected. Connecting the Calibrator to a UUT WARNING The 5500A Calibrator is capable of supplying lethal voltages. Do not make connections to the output terminals when a voltage is present. Placing the instrument in standby may not be enough to avoid shock hazard, since the O key could be pressed accidentally. Press reset and verify that the Y annunciator is lit before making connections to the output terminals. When to Use EARTH The Z key makes a connection between the NORMAL LO terminal and earth ground. When the common ground is not at the UUT, use Z to make a common ground at the calibrator. Four-Wire versus Two-Wire Connections The external sensing capability of the four- and two-wire compensated connections provides increased precision for resistance values below 110 kω and capacitance values 110 nf and above. 16

MIN RANGE HOLD H PEAK MIN mv REL Hz ma A µa MIN RANGE HOLD H PEAK MIN mv REL Hz ma A µa 1000V RMS 1000V RMS 1000V RMS V,, RTD 20V PK V,, RTD 1V PK 20V PK V,, RTD 20V PK A, -SENSE, AUX V 20V RMS 20V PK A, -SENSE, AUX V 20V RMS 20V PK A, -SENSE, AUX V 20V RMS 20V PK 200V PK 200V PK 200V PK Cable Connections 87 TRUE RMS MULTIMETER 5500A CALIBRATOR V V OFF COM A ma A V NORMAL AUX HI LO 1V PK SCOPE TRIG OUT TC UUT Connection: DC Voltage/AC Voltage TRUE RMS MULTIMETER 87 5500A CALIBRATOR V V OFF A ma µa COM V NORMAL AUX SCOPE HI LO TRIG OUT TC UUT Connection: DC Current/AC Current UUT 5500A CALIBRATOR INPUT SENSE Ω 4-WIRE HI LO A HI LO NORMAL AUX SCOPE HI LO TRIG OUT 1V PK TC UUT SENSE SOURCE SOURCE SENSE 5500A UUT Connection: Resistance (4-Wire Comp) 17

MIN RANGE HOLD H REL PEAK MIN MIN RANGE HOLD H PEAK MIN REL Hz Hz 1000V RMS 1000V RMS V,, RTD 20V PK 1V PK 20V PK A, -SENSE, AUX V 20V RMS 20V PK 20V RMS 20V PK 200V PK 200V PK 87 TRUE RMS MULTIMETER 5500A CALIBRATOR mv V ma A V µa OFF COM V A ma A NORMAL AUX HI LO 1V PK SCOPE TRIG OUT TC UUT 5500A UUT Connection: Resistance (2-Wire Comp) TRUE RMS MULTIMETER 87 5500A CALIBRATOR mv V V OFF ma A µa NORMAL AUX V,, A, -SENSE, RTD AUX V HI LO SCOPE TRIG OUT A ma A COM V TC UUT 5500A UUT Connection: Resistance (Comp Off) 18

TRUE RMS MULTIMETER 87 MIN RANGE HOLD H REL Hz PEAK MIN mv ma A µa MIN RANGE HOLD H PEAK MIN REL Hz 1000V RMS 1000V RMS 1000V RMS V,, RTD V,, RTD 20V PK 1V PK 20V PK 1V PK 20V PK A, -SENSE, AUX V 20V RMS 20V PK 5500A CALIBRATOR A, -SENSE, AUX V 20V RMS 20V PK 20V RMS 20V PK 200V PK 200V PK 200V PK UUT 5500A CALIBRATOR INPUT SENSE 4-WIRE HI LO HI LO NORMAL AUX SCOPE HI LO TRIG OUT 1V PK TC UUT Connection: Capacitance (4-Wire Comp) V V OFF A ma A COM V NORMAL AUX HI LO SCOPE TRIG OUT TC UUT Connection: Capacitance (2-Wire Comp) TRUE RMS MULTIMETER 87 5500A CALIBRATOR mv V V OFF ma A µa NORMAL AUX V,, RTD HI LO A, -SENSE, AUX V SCOPE TRIG OUT A ma A COM V TC UUT Connection: Capacitance (Comp Off) 19

60V 24V ON/OFF F/C HOLD OFFSET! 1000V RMS 1V PK 20V PK 1000V RMS 20V PK 1V PK 20V PK 20V RMS 200V PK 20V RMS 20V PK 200V PK CHART RECORDER INPUT 5500A CALIBRATOR NORMAL AUX SCOPE V,, RTD HI LO A, -SENSE, AUX V TRIG OUT TC UUT Connection: Temperature (RTD) 5500A CALIBRATOR K/J THERMOMETER 51 NORMAL AUX SCOPE V,, RTD HI A, -SENSE, AUX V LO TRIG OUT TC Connection wiring must match thermocouple type, e.g., K, J, etc. UUT Connection: Temperature (Thermocouple) Setting the Output Setting DC Voltage Output Sets dc voltage output at 5500A NORMAL terminals. 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure dc voltage. 4. Enter desired voltage output (7 digits). 5. Press I to select polarity. 20

6. Press a multiplier key, if necessary. 7. Press V. 8. Control Display shows entered value. For example, 123.4567 mv. 123.4567 mv 9. Press E. Output appears in Output Display. + 123.4567 mv STBY 10. Press O to activate calibrator output. 330 mv auto Range (Operating Range) Selects autorange (auto) or lock (locked) present range. Setting AC Voltage Output Sets ac voltage output in volts or as a power output in dbm (referenced to a 600 Ω load) at 5500A NORMAL terminals. 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure ac voltage. 4. Enter desired voltage output (6 digits). 5. Press a multiplier key, if necessary. 21 auto locked

6. Press V (volts) or bv (dbm). 7. Control Display shows entered value. For example, 2.44949 V. 2.44949 V 8. Enter desired frequency output (5 digits). 9. Press a multiplier key, if necessary. 10. Press H key. 11. Control Display shows entered value. For example, 1.1234 khz (below). 2.44949 V 1.1234 khz 12. Press E for output in Output Display. STBY 2.44949 V 1123.4 Hz 13. Press O to activate calibrator output. DUTY OFFSET WAVE 50.00 +0.00000 V square 1.00 to 99.00% See specifications sine tri square truncs DUTY (Duty Cycle) Set squarewave duty cycle (1.00 to 99.00%). 22

OFFSET (Voltage Offset) Add positive or negative dc offset voltage. WAVE (Waveform) Select type of waveform. Setting DC Current Output Sets dc current output at 5500A AUX terminals (or 5725A BOOST terminals). 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure dc current. 4. Enter desired current output (6 digits). 5. Press I to select polarity. 6. Press a multiplier key, if necessary. 7. Press A. 8. Control Display shows entered value. For example, 234.567 ma. 234.567 ma 9. Press E for output in Output Display. + 234.567 ma STBY 10. Press O to activate calibrator output. Output at 5500A AUX terminals OUTPUT aux 330 ma auto aux boost auto locked 23

OUTPUT (Output Location) Selects 5500A (aux) or 5725A (boost). If 5725A not connected, OUTPUT softkey does not appear. Range (Operating Range) Selects autorange (auto) or lock (locked) present range. Setting AC Current Output Sets ac current output at 5500A AUX terminals (or 5725A BOOST terminals). 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure ac current. 4. Enter desired current output (6 digits). 5. Press a multiplier key, if necessary. 6. Press A 7. Enter desired frequency (5 digits). 8. Press a multiplier key, if necessary. 9. Press H. 10. Control Display shows entered value. For example, 123.456 ma and 1.1234 khz. 123.456 ma 1.1234 khz 11. Press E for output in Output Display. STBY 123.456 ma 1123.4 Hz 24

12. Press O to activate calibrator output. Output at 5500A OUTPUT WAVE AUX terminals aux square aux boost sine tri square truncs OUTPUT (Output Location) Selects 5500A (aux) or 5725A (boost). If 5725A not connected, OUTPUT softkey does not appear. WAVE (Waveform) Selects one of four different types of waveforms. Setting DC Power Output NOTE Tie the terminals NORMAL LO and AUX LO together at the UUT or at the 5500A, via the LO s softkey selection tied. Sets dc voltage at 5500A NORMAL terminals and dc current on AUX terminals (or 5725A boost terminals). 1. Press R to clear 5500A output. 2. Connect UUT 3. Set UUT to measure dc power. 4. Enter desired voltage output (7 digits). 5. Press I to select polarity. 6. Press a multiplier key, if necessary. 7. Press V. 8. Enter desired current output (6 digits). 9. Press I to select polarity. 25

10. Press a multiplier key, if necessary. 11. Press A. 12. Control Display shows entered value. For example, 123.4567 mv and 234.567 ma. 123.4567 mv 234.567 ma 13. Press E for output in Output Display. STBY +123.4567 mv +234.567 ma 14. Press O to activate calibrator output. 28.9589 mw I OUT LO s AUX tied aux boost tied open (Hint: Enter voltage or current and then a watts entry value using b A. The remaining volts or current value is calculated and displayed.) I OUT (Current Output) Selects 5500A (aux) or 5725A (boost). If 5725A not connected, AUX is in upper case letters. LO s (Low Potential Output Terminals) Ties or opens a connection between front panel NORMAL LO and AUX LO terminals. 26

Setting AC Power Output NOTE Tie the terminals NORMAL LO and AUX LO together at the UUT, or at the 5500A via the LO s softkey selection tied. For optimum phase performance, tie the LO terminals at the UUT. At current levels >2.2 A, tie the terminals at the UUT using heavy gage wire <10 mω resistance. Sets ac voltage at 5500A NORMAL terminals and ac current on AUX terminals (or 5725A boost terminals). 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure ac power. 4. Enter desired voltage output (6 digits). 5. Press a multiplier key, if necessary. 6. Press V. 7. Enter desired current output (6 digits). 8. Press a multiplier key, if necessary. 9. Press A. 10. Enter desired frequency output (5 digits). 11. Press a multiplier key, if necessary. 12. Press H. 13. Control Display shows entered value. For example, 123.456 mv, 234.567 ma, and 1.1234 khz. 123.456 mv 234.567 ma 1.1234 khz 27

14. Press E for output in Output Display. STBY 123.456 mv 234.567 ma 15. Press O to activate calibrator output. 28.9587 mw 1123.4 Hz I OUT AUX WAVE MENUS aux boost HARMONIC MENUS V WAVE sine I WAVE sine LO s tied PHASE 0.00 sine tri square truncs sine tri square truncs tied open 0 to (180.00 (Hint: Enter voltage or current and then a watts entry value using b A. The remaining volts or current value is calculated and displayed.) I OUT (Current Output) Selects 5500A (aux) or 5725A (boost). If 5725A not connected, AUX is in upper case letters. WAVE MENUS (Waveform Menus) Selects type of harmonic, waveform, front panel LO terminal condition, and phase. HARMONIC MENUS (Harmonic Frequency Menus) Selects harmonic outputs. 28

V WAVE (Voltage Waveform) Selects voltage waveform. I WAVE (Current Waveform) Selects current waveform. LO s (Low Potential Output Terminals) Ties or opens a connection between front panel NORMAL LO and AUX LO terminals. PHASE (Phase Difference) Selects phase difference between NORMAL and AUX outputs. Setting a Dual DC Voltage Output NOTE Tie the terminals NORMAL LO and AUX LO together at the UUT or at the 5500A, via the LO s softkey selection tied. Sets dual dc voltages at 5500A NORMAL terminals and AUX terminals. 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure dual dc voltage. 4. Enter desired voltage output at NORMAL terminals (7 digits). 5. Press I to select polarity. 6. Press a multiplier key, if necessary. 7. Press V. NOTE Voltage on the AUX output is limited to 3.3V maximum. 8. Enter desired voltage output at AUX terminals (6 digits). 9. Press I to select polarity. 10. Press a multiplier key, if necessary. 11. Press V. 29

12. Control Display shows entries. For example, 123.4567 mv and 234.567 mv. 123.4567 mv 234.567 mv 13. Press E for output in Output Display. STBY +123.4567 mv +234.567 mv 14. Press O to activate calibrator output. LO tied tied open LO s (Low Potential Output Terminals) Ties or opens a connection between front panel NORMAL LO and AUX LO terminals. Setting a Dual AC Voltage Output NOTE Tie the terminals NORMAL LO and AUX LO together at the UUT or at the 5500A, via the LO s softkey selection tied. Sets dual ac voltages at 5500A NORMAL terminals and AUX terminals. 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure dual ac voltage. 30

4. Enter desired voltage output at NORMAL terminals (6 digits). 5. Press a multiplier key, if necessary. For example, press c. 6. Press V. NOTE The AUX output is limited to 3.3V rms for sinewaves, 6.6 V peak-to-peak for squarewaves, 9.3 V peak-to-peak for triangle and truncated sinewaves. 7. Enter desired voltage output at AUX terminals (6 digits). 8. Press a multiplier key, if necessary. 9. Press V. 10. Enter desired frequency output (5 digits). 11. Press a multiplier key, if necessary. 12. Press H. 13. Control Display shows entries. For example, 123.456 mv, 234.567 mv at 1.1234 khz. 123.456 mv 234.567 mv 1.1234 khz 14. Press E for output in Output Display. STBY 123.456 mv 234.567 mv 31

15. Press O to activate calibrator output. 1123.4 Hz V ; NOR V ; AUX WAVE MENUS HARMONIC MENUS WAVE sine AUX WAVE sine LO tied PHASE 0.00 sine tri square truncs sine tri square truncs tied open 0 to (180.00 V @ NOR (Voltage at NORMAL Terminals) V @ AUX (Voltage at AUX Terminals) Not softkeys. WAVE MENUS (Waveform Menus) Selects type of harmonic, waveform, front panel LO terminal condition, and phase. HARMONIC MENUS (Harmonic Frequency Menus) Selects harmonic outputs. WAVE (Waveform) Selects one of four different waveforms at NORMAL terminals. AUX WAVE (Auxiliary Waveform) Selects one of four different waveforms at AUX terminals. LO s (Low Potential Output Terminals) Ties or opens a connection between front panel NORMAL LO and AUX LO terminals. PHASE (Phase Difference) Selects phase difference between NORMAL and AUX outputs. 32

Setting Resistance Output Sets synthesized resistance output at 5500A NORMAL terminals. 1. Press R to clear 5500A output. 2. Connect UUT. NOTE Be sure terminal connections from 5500A to UUT are LO to LO and HI to HI. 3. Set UUT to measure resistance. 4. Enter desired resistance (6 digits). 5. Press a multiplier key, if necessary. 6. Press Q. 7. Control Display shows entered value. For example, 12.3456 kω. 12.3456 k& 8. Press E for output in Output Display. STBY 12.3456 k& 9. Press O to activate calibrator output. OHMS ZERO COMP off off 2 wire 4 wire OHMS ZERO Zeros the ohms-only function. COMP (Compensation) Applies 4-wire, 2-wire or compensation off (<110 kω only). 33

Setting Capacitance Output Sets synthesized capacitance output at 5500A NORMAL terminals. 1. Press R to clear 5500A output. 2. Connect UUT. NOTE Since this is a synthesized output, be sure the terminal connections from the 5500A to the UUT are LO to LO and HI to HI. 3. Set UUT to measure capacitance. 4. Enter desired capacitance output (5 digits). 5. Press a multiplier key. For example, b then c for µf. 6. Press F. 7. Control Display shows entered value. For example, 123.45 µf (below). 123.45 #F 8. Press E for output in Output Display. STBY 123.45 #F 9. Press O to activate calibrator output. COMP off 34 off 2 wire 4 wire

COMP (Compensation) Applies 4-wire compensation, 2-wire compensation or turns compensation off (>110 nf). Setting Temperature Simulation (Thermocouple) NOTE Make sure the thermocouple wire and plug are not affected by extraneous temperature sources. For example, do not place your fingers on the thermocouple plug or wire when simulating a temperature. Sets a simulated thermocouple temperature output at 5500A front panel TC connector. 1. Press R to clear 5500A output. 2. Connect UUT. NOTE Use thermocouple wire and miniconnectors that match the type of thermocouple. 3. Set UUT to measure temperature. 4. Enter desired temperature output (6 digits). 5. Press C key or for F, b C keys. 6. Control Display shows entered value. For example, 123.456 C. 123.456 ~C 7. Press E for output in Output Display. STBY 123.456 ~C 35

8. Press O to activate calibrator output. NOTE The temperature is cleared to 0 C (32 F) if you change between tc and rtd, or change the type of thermocouple (except a B-type thermocouple is 600 C). Out; TC terminal = 50.0900 mv TC MENUS OUTPUT tc TYPE K rtd tc B C E J K N R S T 10#V/~C UNITS ~C REF SRC intrnl REF NONE TYPE K ~C ~F intrnl extrnl -250 t2316~c B C E J K N R S T 10#V/~C 36

Out@TC terminal (Output at front panel TC terminals) Displays dc voltage at TC terminals. TC MENUS (Thermocouple Menu) Shows submenus for thermocouple outputs. UNITS (Temperature Units) Selects C or F temperature unit. REF SRC (Reference Source) Selects intrnl (Internal) or extrnl (External) reference source. TYPE (Thermocouple Type) Selects emulated thermocouple type. OUTPUT (Temperature Output Device) Selects temperature device: thermocouple (tc) or resistance temperature detector (rtd). TYPE (Thermocouple Type) Selects emulated thermocouple type. Setting Temperature Simulation (RTD) Sets a simulated RTD temperature output at 5500A NORMAL terminals. 1. Press R to clear 5500A output. 2. Connect UUT. 3. Set UUT to measure temperature. 4. Enter desired temperature output (6 digits). 5. Press C key or for F, b C keys. 6. Control Display shows entered value. For example, 123.456 C. 123.456 ~C 7. Press E to output in Output Display. STBY 123.456 ~C 37

8. Press O to activate calibrator output. NOTE The temperature is cleared to 0 C (32 F) if you change between tc and rtd, or change the type of rtd. Output at 5500A NORMAL terminals TYPE pt385 OUTPUT rtd COMP off pt385 pt3926 ni120 rtd tc off 2 wire 4 wire Output at 5500A NORMAL terminal. Displays location of output terminals (always NORMAL). TYPE (RTD Type) Selects rtd curve pt385, pt3926, or ni120. OUTPUT (Temperature Output Device) Selects temperature device: thermocouple (tc) or resistance temperature detector (rtd). COMP (Compensation) Applies 4-wire compensation, 2-wire compensation or turns compensation off. Measuring Thermocouple Temperatures Measures a thermocouple temperature output at 5500A front panel TC connector. 1. Press R to clear 5500A output. 2. Connect thermocouple to TC connector. NOTE Use thermocouple wire and miniconnectors that match the type of thermocouple. 38

3. Press U. to display TC menus. Meas;TC terminal TC OFFSET TYPE = ------- V MENUS 0.00 K -500 to B +500 ~C C E ù J K N R S T 10#V/~C OpenTCD on UNITS ~C REF SRC intrnl REF 27.75 TYPE K on ~C intrnl -250 to B off ~F extrnl 2316~C C E J K N R S T 10#V/~C 39

4. Measured temperature is in Output Display. A small m blinks during a measurement. m 22.58 ~C Measured Value Meas@TC terminal (Measurement at TC terminals) Displays dc voltage at TC terminals. TC MENUS (Thermocouple Menus) Opens submenus supporting thermocouple outputs. Open TCD (Open Thermocouple Detect) Selects on or off for Open TCD feature. UNITS (Temperature Units) Selects C or F temperature unit. REF SRC (Reference Source) Selects intrnl (Internal) or extrnl (External) reference source. REF (Temperature Reference) Displays value of temperature reference. TYPE (Thermocouple Type) Selects emulated thermocouple type. OFFSET (Measurement Display Offset) Selects temperature offset value to be added or subtracted from actual measurement. TYPE (Thermocouple Type) Selects emulated thermocouple type. 40

Waveform Types For AC voltage, ac current, dual ac voltage, and ac power, select between four waveforms. Sinewave For sine, a sinewave is present on calibrator outputs. Variables are amplitude, frequency, and dc offset voltage. Peak RMS (70.7% of Peak) Period Sinewave Trianglewave For tri, a trianglewave is present on calibrator outputs. Variables are amplitude, frequency, and dc offset voltage. Peak to Peak Trianglewave 41

Squarewave For square, a squarewave is present on calibrator outputs. Variables are duty cycle, amplitude, frequency, and dc offset voltage. Period Peak to Peak Decrease Duty Cycle Increase Duty Cycle Truncated Sinewave Squarewave and Duty Cycle For truncs, a truncated sinewave is present on calibrator outputs. Variables are amplitude and frequency. 1/2 Period Peak to Peak 67.5 112.5 Truncated Sinewave 42

Setting Harmonics For dual ac voltages or ac power (sinewaves only), source two signals with adjustable harmonic difference. Fundamentals can be configured on either NORMAL or AUX terminals. 1. Press softkey WAVE MENUS to open waveform menu. 2. Press softkey HARMONIC MENUS to open harmonic menu. 28.9589 mw 1123.4 Hz I OUT AUX WAVE MENUS HARMONIC MENUS V WAVE sine I WAVE sine LO s open PHASE 0.00 60.00 Hz HARMNIC 1 FUNDMTL normal 1 to normal 50 aux 3. Press softkey FUNDMTL to select NORMAL or AUX terminals (or BOOST when 5725A connected) for fundamental. 43

4. Press softkey HARMNIC to enter desired harmonic (1 to 50). For example, 7th harmonic. Press E. Harmonic = 1 New harmonic = 7 5. Press P one or more times to return to previous menus. Adjusting the Phase Sets a phase difference between outputs in dual ac voltage and ac power output modes. 28.9589 mw 1123.4 Hz I OUT AUX WAVE MENUS HARMONIC MENUS V WAVE sine I WAVE sine LO s open PHASE 0.00 Phase = 0.00 New phase = SHOW PF Power factor = 1.000 New pf PF lead SHOW PHASE lead lag 44

Entering a Phase Angle Sets a phase shift in degrees for dual ac voltage or ac power output. 1. Press softkey WAVE MENUS to open waveform menu. 2. Press softkey PHASE to open phase entry menu. 3. Enter desired phase angle (5 digits). 4. Press I to select leading (+) or lagging (-) phase shift. 5. Control Display shows entries. For example, a leading phase angle of 123.45 degrees. Press E. Phase = 0.00 SHOW PF New phase = +123.45 6. Press P one or more times to return to previous menus. Entering a Power Factor Sets a phase shift as a power factor (PF), where PF = Cosine Φ, and Φ is phase shift. 1. Press softkey WAVE MENUS to open waveform menu. 2. Press softkey PHASE to open phase entry menu. 3. Press softkey SHOW PF to open power factor entry menu. 4. Enter desired power factor (3 digits). 45

5. Press softkey PF to toggle a leading (lead) or lagging (lag) power factor. For example, a leading power factor of.678. Press E. Power factor = 1.000 New pf =.678 PF lead SHOW PHASE lead lag 6. Press P one or more times to return to previous menus. Entering a DC Offset Sets a dc offset for single ac voltage outputs. OFFSET WAVE +0.00000 V sine 1. Press softkey WAVE to select desired waveform. 2. Press softkey OFFSET to open offset entry menu. 3. Enter desired offset. For example, 0.123 V. Press E. sine tri square truncs Offset = +0.0000 V New offset = 0.123 V 46

4. Press P one or more times to return to previous menus. Using the 5725A Amplifier In voltage boost mode, 5725A output appears on 5500A NORMAL terminals. In current boost mode, 5725A output appears on 5725A terminals. Redirected 5500A current to 5725A output terminals is 0-2.2 A dc, and 300 µa - 2.2 A ac. Rules of Operation Whenever B key annunciator is on, 5725A voltage boost or current boost amplifier is in use. If 5725A Current Amplifier indicator is on, while B annunciator is off, 5500A current is being redirected to 5725A. When sourcing current, OUTPUT softkey choice AUX or BOOST takes precedence over Source Preference softkey and front panel B key. Exception: When selected current cannot be sourced by 5500A, output automatically switches to BOOST and displays Current OUTPUT moved to 5725A in Control Display. Source Preference softkey chooses 5500A or 5725A when either can source output. B key is a temporary Source Preference selection. Any current or voltage combination outside capabilities of 5500A but within capabilities of 5725A will activate 5725A output. 47

5725A Amplifier Output WARNING Boosted voltage operation produces high voltage at higher current levels than normally available from the calibrator. During boosted voltage operation, the potential risk of injury or fatal accident is greater than during normal operation. Set a boosted output from 5725A Amplifier: 1. Press R to clear 5500A output. 2. Install 5725A, as described in 5725A manual. 3. Connect UUT. For boosted current, connect to 5725A terminals; for boosted voltage, connect to 5500A NORMAL terminals. 4. Set UUT to measure output. 5. Set source preference to 5725: press front panel S key; softkey INSTMT SETUP; softkey OUTPUT SETUP; softkey SOURCE PREFRNCE to select 5725. 6. Press P key one or more times to return to previous menus. 7. Enter desired output value described under Setting the Output. NOTE You can have the 5725A source a dc current below 1.5 A to take advantage of the amplifier s higher compliance voltage. To do so, press the RANGE softkey to lock onto the 11 A range when the 5500A is set for over 2.2 A, or set the lower current and press B O to turn on the amplifier. 8. Press B key. 48

Editing and Error Output Settings Edit outputs using Edit Field knob and associated L, W, and e keys. In addition, multiply X and divide D keys edit output by decades. Keys That Exit Error Mode.H\V $FWLRQ E I E Keypad entry + E N X D R Returns to previous reference value. New reference. New reference. Present output as new reference. Sets calibrator to x10 reference value and new reference. Sets calibrator to 1/10 reference value and new reference. Returns to power-up state. Editing the Output Setting Turn Edit Field knob clockwise to increase output value or counter-clockwise to decrease output value. To select higher order digit, use Edit Field cursor key L or W. Output digit in edit is always underlined. + 10.00030 V OPR 49

Displaying the Output Error Edit output so UUT displays expected value and thus indicates UUT accuracy. ref= +10.00000 V err= -30.0 ppm For example, edited difference of.00030 volts for output of 10.00000 V represents.00030/10.00000=.000030, or 30 parts per million. Using Multiply and Divide Press X key to multiply output by x10. Press D key to divide output by 1/10. If multiplied output exceeds 33V, 5500A is placed in STBY (Standby). Setting Output Limits Output limits help prevent accidental damage to UUTs from overcurrent or overvoltage. Selections are saved in nonvolatile memory. Voltage limits are expressed in rms. Setting Voltage and Current Limits Sets voltage and current limits. 1. Press R to clear 5500A output. 2. Press S. Press softkey INSTMT SETUP to open setup submenus. 3. Press softkey OUTPUT SETUP to open output setup submenus. 50

4. Press softkey SET LIMITS to open set limits menu. DISPLAY OR CHANGE ENTRY LIMITS VOLTAGE CURRENT 5. To Limit Voltage (applies to both dc and ac voltages) Press softkey under VOLTAGE. V+ LIM 1000.0000 V- LIM -1000.0000 UPPER LIMIT LOWER LIMIT a. Press Upper Limit or Lower Limit softkey, as desired, and enter new limit. b. Press E then P one or more times to return to previous menus. 6. To Limit Current (applies to both dc and ac currents) Press softkey under CURRENT. I+ LIM 11.0000 I- LIM -11.0000 UPPER LIMIT LOWER LIMIT a. Press Upper Limit or Lower Limit softkey, as desired, and enter new limit. b. Press E then P one or more times to return to previous menus. 51

52