Design and industrial application of a microsurfacing pavement based on non-venezuelan bitumen.

Similar documents
Session 2. EMULSIONS: The COLAS DNA THE NEW EMULSION PLANT IN GALWAY An integrated business model

The Shell Bitumen Handbook

CONTROL AND RESEARCH LABORATORIES IN THE ASPHALT INDUSTRY

A5EE-337 DURABILITY OF A BITUMEN IN A HOT MIX ASPHALT: CONSEQUENCES OF OVER-HEATING AT THE MIXING PLANT

Part 1. Introduction

Asphalt ( Bitumen ) Chemistry and Emulsion Performance. Glynn and Irina Holleran

Seal Coats and Surface Treatments Fred J. Benson, Dean of Engineering A. and M. College of Texas College Station, Texas The construction, as here

* TP: +94(0)

Glass beads surface dressing test section

Presented at 24th AEMA Meeting, March 14-16, 1997, Cancun, Mexico

Roll Out Vinyl Installation Guide

ADHEBIT Adhesion Promoters

Commonwealth of Pennsylvania PA Test Method No. 517 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

TECHNICAL DATA SHEET PlastiRoute RP-2C All Colours

AASHTO IDRRIM meeting

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

Studies of the microstructure of polymer-modified bitumen emulsions using confocal laser scanning microscopy

BEST PRACTISE AND SHARING TECHNICAL EXCHANGE PLATFORM IN ATEB

Asphalt Emulsion Basics

METHOD OF TEST FOR DETERMINATION OF THE SEVERITY OF A SEGREGATED ASPHALT PAVEMENT SURFACE

AIR-RECTIFIED BITUMNEN

12A Distance, Time, and Speed

Manufacture of Cast Products

MICRO MILLING. Applications and Advantages for Pavement Preservation

Jointed Precast Concrete Pavement

EFFECT OF GRADATION OF AGGREGATES ON MARSHALL PROPERTIES OF SDBC MIX DESIGN

Technically Unavoidable Particles Profile (TUPPs) Guide

Maximising Durability and Performance of Marking Systems. NZRF Conference Rotorua Aug

FOAMED BITUMEN STABILISATION PROJECT WARWICK, QLD

Factors Affecting Quick Lime Consumption In Dry FGD

Novel Technique of Laying Bitumen Roads Using Light Detection and Ranging [LIDAR]

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

ADHESION VERSUS SCRUBBABILITY By Bob Cusumano

INTERNATIONAL JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (IJCIET)

Mat 100w/150w/200w LIFETIME INSTALLATION MANUAL WARRANTY

R & D PROJECTS

ASPHALT MACHINES AND EQUIPMENTS

The development of EME in Europe requires an. for the climate. Tine Tanghe Hilde Soenen NCCA, Nynas NV

Automatic hardness testing devices

DEVELOPMENT OF RUBBER BINDER SPECIFICATIONS IN CALIFORNIA: PROJECT UPDATE

DESIGN OF THE ASPHALT LAYER ON HIGH SPEED LINES

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

Managing. Efflorescence. on Concrete pavers. A guide for consumers

Evaluation of bitumens consistence modified by polymers at equipenetrating temperature

Effect of Slaking Water Temperature on Quality of Hydrated Lime Slurry By: Mohamad Hassibi Chemco Systems, L.P. July, 2009 Revised: June 20, 2015

EXPERIMENTAL STUDIES ON THE PROPERTIES OF MODIFIED BITUMINOUS MIXES USING CRUMB-RUBBER

To: New York State Department of Transportation ENGINEERING INSTRUCTION. Approved:

Case Study: Roofing Shingle Scrap in Hot Mix Asphalt, TxDOT Dallas District. Project Overview

Preparation and evaluation of demulsifiers agents for Basra crude oil

Job Report Cold Milling. Wirtgen FCS Light: Increased flexibility and utilization of cold milling machines

NEW TECHNOLOGY & APPROACHES TO ADDRESS PAVEMENT CONSTRUCTION ISSUES

An Experimental Study on Effect of Scrap Tyre Crumbed Rubber on 80/100 Grade Bitumen

Improving Drying rates of Waterborne Pavement Markings

Evaluation of High Recycled Asphalt Pavement Contents in Warm Mix Asphalt Technologies

Why Do We Saw Equipment Types Matching Equipment to the Project Blade Selection Ensuring Construction Quality When Things Don t Go Right The Sawing

BITUMEN EMULSION AND FOAM BITUMEN FOR COLD RECYCLED AND BITUMEN STABILIZED MATERIALS: A COMPARISON BASED ON PERFORMANCES, COSTS AND SAFETY

UNGLAZED UNFLASHED Earthen Tones

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-comp. FLUOX daylight luminescent paint system TECHNICAL INFORMATION

STABILIZATION OF SANDY SOIL WITH USE OF BITUMEN EMULSION

EXPERIMENTAL STUDY ON PARTIAL REPLACEMENT OF BITUMEN BY RECYCLED RUBBER FROM TYRE ON ASPHALT PAVEMENT

Innovative laboratory equipment. Preliminary testing to determine the mix quality.

Nondestructive measurement of layer thickness with the MIT-SCAN-T2

Eccentric vibrating mill

Fibertex AM2 for Stress relieving

Update on status of X-ray CT imaging and associated work at TFHRC

Performance Evaluation Of Recycled Bitumen Before And After The Addition Of Plastic Waste

Innovative composite dowel for steel concrete composite bridges. Neil Westmacott, Wolfram Schwarz

DMS-8220, Hot Applied Thermoplastic

Hot to Hot the Whole Night Long

A Study on Comparison of Plastic Bitumen and Crumb Rubber Bitumen

Portable retroreflectometers and structured pavement markings

IJSER. Experimental Investigation of Increase The Strength of Bitumen By Using Plastic

Industrial Waxes Chemistry & Blending

PILLING CAPACITY ASSESSMENT OF COTTON KNITTED FABRICS AFTER FINISHING PROCESS

Active microwave moisture sensors advanced solutions for the pulp and paper industry

SMALL BEADS, GREAT EFFECT

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

Increasing Filler Without Compromise

Lapping Plate 05M20.20

Rollei Tripod Rock Solid Beta 180 Carbon FIELD TEST. Author: Solli Kanani June 2017

Ground Penetrating Radar (GPR) By Dr. Eng. Zubair Ahmed

Precast Bendable Concrete Paving Slab for Speedy Road Construction

ADDING VALUE TO YOUR BUSINESS

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY

White Paper WP008. Cover. 1/14 1/14 Architectural Precast Applications. Architectural Precast Applications

Reflection and retroreflection

Ink Properties to maximise production potential!

TECHNICAL BULLETIN BELT FINISHING WITH MICRO-MESH

Use of PFOA in critical photographic applications

Printing Quality Assurance

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

ROADMIX'S EXPERIENCE IN BITUMEN-RUBBER

PCTC Guide Specification-PCTC01

The art of consistency

High Volume Digital Print Production and Workflow Automation

PPETG - Emulsion Task Force Update (ETF) By: Colin A. Franco, P.E. Associate Chief Engineer RIDOT 2016 AEMA-ARRA-ISSA Annual Meeting

MURE National Project: FTIR spectroscopy study to assess ageing of asphalt mixtures

Change in Bitumen Quality during the working stations

Enhancing Skid Resistance of Two-Component Road Marking Paint using Mineral and Recycled Materials

Laboratory foamed bitumen plant WLB 10 S and twin-shaft compulsory mixer WLM 30. Preliminary testing to determine the mix quality.

Transcription:

Design and industrial application of a microsurfacing pavement based on non-venezuelan bitumen. Claude Emmanuel Giorgi 1, a, Frédéric Loup 2, Delphine Simard 2, Jérémy Thomas 3 1 Technical Management, EIFFAGE Travaux Publics, Neuilly/Marne, France 2 Central Laboratory, EIFFAGE Travaux Publics, Corbas, France 3 Regional Laboratory, EIFFAGE Travaux Publics, Le Haillan, France a claude.giorgi@eiffage.com Digital Object Identifier (DOI): dx.doi.org/10.14311/ee.2016.213 ABSTRACT The study presented in the paper focuses on the design of the next generation of microsurfacing pavements. This technique consist of applying in-situ a thin layer of a cold mix in order to regenerate the macro texture and the waterproofing of an aged wearing course. This technique has been getting bigger every year for the last 20 years, especially in France where more than 50 million square meters are applied every year. This technique relies on the use of asphaltenic bitumen from Venezuela to get fast cohesion built up and minimal impact on traffic. For years, many alternatives were studied to replace Venezuelan bitumen, with different results, but still Venezuelan bitumen was preferred to get the best quality. In 2014, Eiffage s central laboratory worked on a brand new microsurfacing design, based on the use of a special chemistry, enabling the use of any type of bitumen to get the same results of the one coming from Venezuela. To be able to achieve such a performance, a new methodology was set up to characterize in a more effective way properties of the new design. The same year, first jobsites were laid down using this new technology, covering more than 150 000 square meters of roads. In 2015, this new design was generalized and more than 800 000 square meters were laid down. Keywords: Asphalt, Cohesion, Mixture design, Slurry seals, Testing

1. INTRODUCTION Microsurfacing pavement have been used intensively in Western Europe and especially in France for the last 30 years, where more than 50 million square meters [1] are applied each year. This technique relies on the use of asphaltenic bitumen from Venezuela to get fast cohesion built up and minimal impact on traffic. For years, many alternatives were studied to replace Venezuelan bitumen, with different results, but still Venezuelan bitumen was preferred to get the best quality. In 2014, EIFFAGE s central laboratory worked on a brand new microsurfacing design, based on the use of a special chemistry, enabling the use of any type of bitumen to get the same results of the one coming from Venezuela. To be able to achieve such a performance, a new methodology was set up to characterize in a more effective way properties of the new design. The same year, first jobsites were laid down using this new technology, covering more than 150 000 square meters of roads. In 2015, all microsurfacing applied by EIFFAGE Travaux Publics in France were using this new technology. 2. LABORATORY DESIGN - METHODOLOGY 2.1: Current State of Art: Microsurfacing products are currently tested according the EN 12274 series of European standards. One of the difficulties in designing such products is to evaluate the minimum cohesion of the mix to open the traffic. Ideally, because this technique is widely used in urban areas and minimal disturbance is then required, traffic time around 20-30 minutes are often required. The cohesion test EN 12274-4 [2] relies on the use of the Benedict appliance, which basically measures the torque of a rubber piece on the surface of the product after the desired time (20 or 30 minutes). Minimum values are required to validate the mix design and evaluate the traffic time. This test is generally combined with the Wet Track Abrasion test (WTAT EN 12274-5) [3] to evaluate the wearing of the surface of the product under traffic simulation and under water. This test is very useful to validate the compatibility of a given aggregate with the chemical composition of the mixing emulsion used to make the microsurfacing pavement. Below are photographs of the two tests. Photos 1 & 2: Benedict and Wet Track Abrasion Tests

However, this methodology can sometimes be misleading as high torque values can be obtained by the result of friction between the piece of rubber on a loose aggregate of the mix. As the use of napthtenic bitumen was generalized, these variations due to the imperfection of the tests were not so critical as finally the mix was curing quickly on the jobsite. But with the development of a new generation of emulsion using traditional/paraffinic bitumen, this parameter was becoming much more sensitive and our central laboratory developed new testing methods to better and in a more secure way evaluate the cohesion build-up of these types of mixtures. 2.2: New Methodology: 2.2.1: Mixing tests. Mixing tests are usually the first step necessary to adjust the emulsion design for a microsurfacing pavement. Mixing the emulsion with the aggregates and the different components of the mix (water, retarder, cement etc ) enables to adjust the dosage of the emulsifier into the emulsion so the mix can comfortably applied by the slurry paver on the jobsite. It might differ with the experience of each contractor, but it is generally admitted that a breaking time comprised between 2 and 3 minutes is ideal (Tests are performed at the expected temperature on the jobsite). In addition to this breaking time, we decided to use the basic test to get even more information. We noticed that the faster the curing the better the stripping was on the sulfurized paper the mix was applied. By stripping, we mean traces of emulsion or bitumen. The ideal would be to have no traces whatsoever on the paper after the estimated traffic time (20 or 30 minutes). We found that was a good indicator of the curing and the consistency of the mix. In addition to this observation, we evaluated the cohesion built-up of the mix by performing a ball test with the mix. The time after which a ball could be made without falling apart was also a simple but good indicator of the stiffness and cohesion of the mix. Below is a picture (photo 3) of the stripping and ball test on a mix in the laboratory. * Photo 3 : Stripping and ball test.

In the process of designing a suitable emulsion based on paraffinic bitumen in a microsurfacing system we evaluated these parameters with our candidate emulsions. Below is an example of results that we obtained during the design of candidate emulsions. Table 1: Results of mixing tests Note: All names appearing in this table are internally coded in references of laboratory samples and or do not refer to commercial names. EM 13150 was our reference emulsion based on Venezuelan bitumen. It is interesting to note that at this stage of the design another candidate emulsion EM 13152 based on a traditional paraffinic bitumen fulfills also all the required parameters as far as breaking time, stripping and ball tests are concerned. 2.2.1: Hilt Cohesion Test - HCT Test The Hilt Cohesion Test is a non-standardized method developed by COLAS [4] to better estimate the cohesion built-up of a mix. As already mentioned, the Benedict Test described in the EN 12274-4 standard can really be misleading, even though the different evaluations described above during the mixing tests already give important information on the speed of cohesion of the mix. Samples of 10 x 10 x 1 cm are manufactured in the lab and tested after 30 minutes. The idea is to estimate the time necessary (in seconds) for a sample to break under its own weight (see picture 4 below). Photo 4: Hilt Cohesion Test A poor performing sample will break nearly immediately with only a few seconds before falling apart, whereas it will take nearly one minute for a good candidate before failing the test.

The table below (table 2) shows the results obtained with different designs based on paraffinic bitumen compared to the reference one made with Venezuelan bitumen (EM 13 350). Emulsion Chemical % chemical % added water % retarder Breaking time (s) Benedict test 20 min 40 min HCT (s) Comments EM13550 Emulsifier A 1.5 2 1 95 25 30 51 Reference Emulsion With naphthenic bitumen EM13516 Emulsifier A 1,5 3 0 95-100 18 20 6 Same emulsion as reference but with paraffinic bitumen EM13534 Emulsifier A 1,5 2 1 95 21 25 26 EM13551 Emulsifier B 1 3 0 90 25 30 32 Improved EM13552 Emulsifier D 1 3 0 90 27 32 32 Emulsion with paraffinic asphalt EM13556 Emulsifier E 1 2 1 55 24 30 36 EM13555 Emulsifier C 0,7 2 1 85 23 19 Table 2: Results from Hilt Cohesion Test The EM 13350 represents our reference emulsion designs based on traditional naphthenic bitumen used for microsurfacing. The EM 13516 is the same emulsion but made this time with traditional paraffinic bitumen. The difference speaks for itself with 51 seconds for our reference emulsion and 6 seconds for the one base on paraffinic bitumen before failing the test. All the other candidate emulsions show the improvement made in the emulsion design with for certain samples values reaching 30-40 seconds, very close to the reference EM 13350. We settled our choice on the EM 13352 design as both the mixing time and the Hilt Cohesion Test were giving satisfactory results. This is also the same design that previously passed successfully the stripping and ball tests.

3. APPLICATION- Industrial production and first jobsites, 3.1: Initial trial: Importance of the particle size of the emulsion. The very first trial took place in Normandy during the 2014 season. Though all the emulsion designs were satisfactory in the laboratory, the first trial did not prove as successful as expected, as the mix was very slow to cure, with a traffic time estimated around two hours. The two photos below illustrate this phenomenon, with still unbroken emulsions after more than 90 minutes after layingdown. Photo 5 and 6: Unbroken emulsion on jobsite Several investigations were made to try to understand what happened. Designs were made in our laboratory with the same raw materials that the ones manufactured in the emulsion plant and excellent results were obtained. Emulsion Chemical % chemical % added water % retarder Breaking time (s) Benedict test 20 min 40 min HCT (s) Comments EM 14 524 Emulsifier D 1.0 3 1 85 26 30 34 Emulsion manufactured in laboratory EM 14 525 Emulsifier D 1.0 3 1 400 8 12 1 Emulsion manufactured in plant Table 3: Evaluation of the same emulsion design manufactured in laboratory or plant It seemed obvious that the process of the plan t was interfering with the quality of the emulsion manufactured but so far our methodology was not able to really focus on the parameter that caused the problem. Quality control tests based on Breaking Index (EN 13075-1), water content (EN 1428) or ph (EN 12850) did not show any differences on the properties of the emulsion.

Further investigations showed that the particle size of both emulsions was different and that this could be the main reason of what was observed on the jobsite. Indeed, to get an even breaking and curing of the mix, small and uniform particles are necessary (unimodal curve gauss type photo 7). On the contrary, a multimodal, distribution, with bigger particles (photo 8) could lead to partial and delayed curing, similar to what was observed on the jobsite. Photo 7: Gaussian curve Lab production Photo 8: Multimodal curve Plant production After maintenance of the plant s mill and fine tuning of its gap, we were able to produce again very fine emulsions giving excellent and satisfactory results on the jobsite, as shown on the photos below (photos 9 and 10). Photo 9: View of the jobsite during application Photo 10: Surface texture It is interesting to note the fast curing of the mix on photo 9, comparing the lane on the right that has already become black while the second one is being laid down. The final rendering of the microsurfacing on photo 10 is perfect. In addition to all the methodology that we specially implemented for the design of this new generation of micro surfacing (described in the 2 of the paper) we specified also specific values on the particle size of the emulsion: D0.5 < 5 µm D0.9 < 10 µm

3.2: 2015 Micro surfacing campaign. Following the excellent results obtained in Normandy at the end of 2014, we decided to generalize the use of our new emulsion in 2015. Therefore, this new micro surfacing was applied in various regions of France, such as the departments of Seine-Maritime (76), Eure (27), Vendée (85), Dordogne (24), Gironde (33), Charente (16), Vienne (86) and Rhône (69) for a total of more than 800 000 square meters. Below are a few pictures of the different jobsites: Photo 11 : Gironde (33) photo 12: Dordogne (24) photo 13 : Vienne (86) We even took the opportunity of one jobsite to compare our new emulsion with the traditional one based on Venezuelan bitumen. No differences were observed between the two sections (cf photo 14 below). Photo 14: Venezuelan bitumen on the left Paraffinic bitumen on the right

4. CONCLUSION - PERSPECTIVES The development of this new emulsion design and its implementation took nearly 18 months within the research teams of Eiffage Infrastructures. All this body of work was also the opportunity for us to redesign completely our methodology and to better approach the cohesion built-up of the mix. Importance of the emulsion production was also highlighted, showing the importance of team work during the development of new products between the different departments of the Company, from Research to Industry and Production. This is certainly a key parameter in the quick and successful implementation of a new product/process in any organization. Networks and relationships were strengthened during this project and no doubt that this will be the success of our further developments to come. Finally, this generation of new microsurfacing pavements are also an opportunity for Eiffage Infrastructures to be more competitive in Europe and be able to introduce this technology in countries where the availability of Venezuelan bitumen is impossible. This is in total concordance with the international Development of the Eiffage Group. 5. REFERENCES [1] I.Cavagnol, Direction des Affaires Techniques, USIRF, Bilan Environnmental 2013, May 2014 [2] EN 12274-2: Slurry surfacing Test methods Part 4: Determination of cohesion of the mix. [3] EN 12274-5, Slurry surfacing Test methods Part 5: Determination of wearing. [4] Ch. Deneuvillers, J.Samanos, Eurasphalt, Eurobitume Congress September 20-22 nd 2000, Barcelona, Spain. TEST METHODS AND INNOVATIVE DESIGN FOR MICROSURFACI