Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

Similar documents
PD Solutions. On-Line PD Measurement Devices

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Open Access Application of Partial Discharge Online Monitoring Technology in ± 660kV Converter Transformer

Why partial discharge testing makes good sense

PD Diagnostic Applications and TechImp solutions

PD ANALYSIS OF GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR DURING FACTORY ASSEMBLY AND SITE COMMISSIONING

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Frequency Spectrum Analysis of Electromagnetic Waves Radiated by

The Application of Partial Discharge Measurement and Location on CGIS

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

APPLICATIONS OF ACOUSTIC LOCALIZATION TO ONLINE POWER TRANSFORMERS

KEYWORDS On-line diagnostics, cable termination, partial discharge (PD), ultra-high frequency (UHF), sensitivity check.

Partial Discharge Monitoring and Diagnosis of Power Generator

Electrical Equipment Condition Assessment

UHF PARTIAL DISCHARGE DIAGNOSIS OF PLUG-IN CABLE TERMINATIONS

Suppression of Pulse Interference in Partial Discharge Measurement Based on Phase Correlation and Waveform Characteristics

IN HOUSE CALIBRATION OF PD DETECTOR SYSTEM FOR FIELD TEST RESULT RELIABILITY

NEW MV CABLE ACCESSORY WITH EMBEDDED SENSOR TO CHECK PARTIAL DISCHARGE ACTIVITY

Abstract. 1 Introduction

Partial Discharge Signal Detection by Piezoelectric Ceramic Sensor and The Signal Processing

A STUDY ON THE PERFORMANCE OF IMPEDANCE MATCHING CIRCUIT IN PARTIAL DISCHARGE MEASURING SYSTEM

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

Diagnosis of Water Tree Aging in XLPE Cable by the Loss Current Harmonic Component Under Variable Frequency Power

Diagnostic testing of cast resin transformers

WinTech Partial Discharge Testing and Monitoring Systems

Coherence and time-frequency analysis of impulse voltage and current measurements

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

Partial discharge diagnostics on very long and branched cable circuits

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

Investigation of PD Detection on XLPE Cables

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

PARTIAL DISCHARGE DETECTION AND LOCATION IN TRANSFORMERS BY PERFORMING PARTIAL DISCHARGE TESTS IN OIL USING UHF SENSORS

Transient calibration of electric field sensors

Software for Partial Discharge and Localization

PARTIAL DISCHARGE MEASUREMENT ON ROTATING MACHINES

Partial Discharge Patterns in High Voltage Insulation

IEEE Transactions on Power Delivery. 15(2) P.467-P

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

1409. Comparison study between acoustic and optical sensors for acoustic wave

Partial Disconnected Cable Fault Detection Using Improved SSTDR

PARTIAL DISCHARGE MEASUREMENTS ON GENERATORS USING A NOISE GATING SYSTEM

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

UHF PD-DIAGNOSIS AT HIGH VOLTAGE CABLE TERMINATIONS INTERNATIONAL CASE STUDIES

PULSE-SEQUENCE ANALYSIS OF PARTIAL DISCHARGES IN POWER TRANSFORMERS

WAVELET DE-NOISING AND ANALYSIS OF UHF PARTIAL DISCHARGES IN HIGH VOLTAGE POWER TRANSFORMER

Measurement of Partial Discharge inside Metal Enclosed Power Apparatus using Internal Sensor

Research on the Effect of High Power Microwave on Low Noise Amplifier and Limiter Based on the Injection Method

Partial Discharge (PD) techniques for measuring the condition of ageing HV/MV switchgear

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

International Conference on Information Sciences, Machinery, Materials and Energy (ICISMME 2015)

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

PARTIAL DISCHARGE DETECTION - AN OVERVIEW

A Compiler Design Technique for EMS Test CS115

Open Access Partial Discharge Fault Decision and Location of 24kV Composite Porcelain Insulator based on Power Spectrum Density Algorithm

PD Testing Considerations for MV Plant Cables

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators

Extended analysis versus frequency of partial discharges phenomena, in support of quality assessment of insulating systems

A1-209 EXPERIENCES IN IDENTIFICATION OF PARTIAL DISCHARGE PATTERNS IN LARGE HYDROGENERATORS

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

SMART CABLE GUARD A TOOL FOR ON-LINE MONITORING AND LOCATION OF PD S AND FAULTS IN MV CABLES ITS APPLICATION AND BUSINESS CASE

PARTIAL DISCHARGE MEASUREMENT

CONDITION MONITORING OF MEDIUM VOLTAGE ELECTRICAL CABLES BY MEANS OF PARTIAL DISCHARGE MEASUREMENTS

Statistical Characteristics of Partial Discharge Caused by Typical Defects in Cable Joint under Oscillating Voltage

Equipment under Measurement: 6.6kV Alstom AIS Switchgear. Date of Measurement: 10 th August 2017

Evaluation of Partial Discharge in Power Transformers by Acoustic Emission Method and Propagation Modeling of Acoustic Signal

NJ. ISBN (2017) , /URSIGASS

Gas-Insulated Metal-Clad Switchgears Express-Diagnostics Method on Partial Discharge Characteristics

An UWB Printed Antenna for Partial Discharge UHF Detection in High Voltage Switchgears

MONTRANO. Continuous monitoring system for power transformers

The importance of partial discharge testing throughout the development and operation of power transformers

Life Prediction of Mold Transformer for Urban Rail

USING DAMPED AC VOLTAGES

Analysis of Partial Discharge Patterns for Generator Stator Windings

Design of Meander Antenna for UHF Partial Discharge Detection of Transformers

Antenna Array Layout for the Localization of Partial Discharges in Open-Air Substations

Open Access Partial Discharge Fault Decision and Location of 24kV Multi-layer Porcelain Insulator based on Power Spectrum Density Algorithm

Electrical Power Engineering Group, School of Electronics and Computer Science, University of Southampton, Highfield, Southampton, SO17 1BJ, UK 2

SENSITIVITY ASPECTS OF ON-LINE PD DIAGNOSIS OF MV POWER CABLES

PD ANALYSIS OF GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR DURING FACTORY ASSEMBLY AND SITE COMMISSIONING

Comparison of capacitive and inductive sensors designed for partial discharges measurements in electrical power apparatus

Partial Discharge, Survey or Monitor?

Design of Dual Mode DC-DC Buck Converter Using Segmented Output Stage

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Design and verification of internal core circuit of FlexRay transceiver in the ADAS

Florian Predl and GK Papneja OMICRON

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

On-Site Partial Discharge Monitoring using the differential LEMKE PROBE LDP-5 and its accessories

Research Article Wideband Microstrip 90 Hybrid Coupler Using High Pass Network

Evaluation and Limitations of Corona Discharge Measurements An Application Point of View

A 600 GHz Varactor Doubler using CMOS 65nm process

TECHIMP Power Transformer Monitoring

Research Article CPW-Fed Wideband Circular Polarized Antenna for UHF RFID Applications

CVVOZE Power Laboratories (CVVOZEPowerLab)

Transcription:

TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS Vol. 14, No. 4, pp. 211-215, August 25, 2013 Regular Paper pissn: 1229-7607 eissn: 2092-7592 DOI: http://dx.doi.org/10.4313/teem.2013.14.4.211 Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor Jong-Yeol Shin Department of Car Mechatronics, Sahmyook University, Seoul 139-742, Korea Young-Sang Lee, and Jin-Woong Hong Department of Electrical Engineering, Kwangwoon University, Seoul 139-701, Korea Received January 24, 2013; Revised May 21, 2013; Accepted July 4, 2013 Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China s semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements. Keywords: Ultra high frequency, High voltage switchgear, Gas insulated switchgear, Partial discharge, Insulation, Diagnosis techniques 1. INTRODUCTION As industry technology advances, a natural consequence is Author to whom all correspondence should be addressed: E-mail: ealab@kw.ac.kr Copyright 2013 KIEEME. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. an increased demand for power. That in turn places greater demands on electric power infrastructure systems. This calls for an urgent policy for power outage accidents. The checking pre-diagnosis in the existing policy for power outage accidents is mainly centered on the aftermath of interruption of the operation of power equipment, but in recent years, after the diagnosis in live state has been actively studied domestically and internationally, many research and related products have been introduced as technology used in various fields. Researchers have applied ultrasonic measurement techniques and gas analysis techniques Copyright 2011 KIEEME. All rights reserved. 211 http://www.transeem.org

212 Trans. Electr. Electron. Mater. 14(4) 211 (2013): J.-Y. Shin et al. to withstand voltage, measured as acid, a method for measuring the electromagnetic wave by ultra-high frequency (UHF) sensors embedded in the insulation to ultra high voltage transfers in the fields. Gas insulated switchgear (GIS) having a visual effect is commercially available online, and portable systems using the UHF sensors are installed and operated in power company, railroad and large plants [1,2]. However, the live diagnosis depending on the classic method, such as existing infrared cameras and leakage current measurement method in the case of ultra high voltage switchgear, is not effective for the prevention of power outage accidents, because the switchgear internal structure is complex, and it is difficult to determine the occurrence of partial discharge [3]. As a live-diagnosis technique of GIS, UHF technology was applied to the switchboard, and the possibility of application studied [4,5]. The technology by using UHF sensors is simply measured, and the interpretation of diagnostic results is an easy technique, as waveform analysis is standardized by the result of numerous studies. In this paper, the measured result was characterized, and offered to ultra high voltage switchgear under commercial operation. The use of UHF partial discharge measurement technique has started to be actively applied domestically and internationally, and it has been confirmed that the reliability of UHF diagnosis techniques in utilizing ultra high voltage switchboard diagnosis is sufficient. The result is hereby introduced. 2. EXPERIMENT 2.1 Live-existing partial discharge diagnostic techniques There are many types of partial discharge live diagnostic techniques: methods for measuring the middle joint material, for measuring the capacitance using the sensor of a capacitive coupler type, measuring the leakage currents flowing in the ground wire, using infrared cameras, and using an UHF sensor, etc. [6,7]. As a diagnosis using an ultrasonic sensor is the diagnostic method of a sensor attached to joints in the middle of the cable, it actually is a diagnostic technique that is rarely used by itself in application in the field, because of the vibration of the cable itself, the risk of measurement when the sensors is attached directly to the middle joint, the difficulty of access to the site, and the difficulty of distinguishing between signal and noise. It is difficult to analyze the signal in a measurement method using capacitive sensors with capacitive couplers, and the technique is affected by surrounding noise. The diagnostic technique using a HFCT(high frequency current transformer) is a technique to measure leakage current through the ground wire, when partial discharge occurs. As it is a method of measurement using a HFCT with 20 MHz ~ 30 MHz measurement bandwidth, it is easy for signal processing hardware, because its frequency band is lower than UHF (500 MHz - 1,500 MHz). However, this is an excellent method to use in the laboratory, except for its difficulty in distinguishing and analyzing between the circulating current and the leakage current caused by partial discharge, because the circulating current flows to the ground wire. To overcome such problems, some partial discharge diagnostic equipment companies have studied the distinction betwen the intrinsic partial discharge signal and the noise through FFT analysis, as 3 HFCT are connected to each signal ground wire on cable R, S, T phases of the cable at one time. A widely used diagnostic technique using infrared cameras has been applied in the field for a long time. The diagnosis of part of the whole shoot is easy in the equipment of complex structures, such as ultra high voltage, but the diagnosis is difficult for the shadow zone that can t be shot, of the rear part of the equipment. This technique is widely used as an auxiliary means of partial discharge localization tracking for locations where partial discharge is known to have occurred, through a method such as UHF diagnostic technique. 2.2 UHF partial discharge diagnostic techniques UHF technology, a technique involving the surface of the metal making up the power plant, the internal and surface of the insulation, and measuring the partial discharge occurring on the metal and the joint parts of the insulator, is a technique that can easily measure and analyze in the field of a substation. Various power equipment, including ultra high voltage and breakdown accident, suffer production defects, construction defects and environmental cause while driving. More than half of the power equipment failure are accidents due to the breakdown, which is always accompanied by partial discharge phenomena. It is accompanied by various phenomena, such as partial discharge, discharge current, acoustic signal, light, and electromagnetic radiation. As UHF technology is a method to detect the radiating electromagnetic wave when partial discharge occurs in the power equipment, a method to detect partial discharge is embedding UHF band antenna sensors inside power equipment. The electromagnetic waves generated by partial discharge have features to be distributed to broadband frequency more than GHz. These electromagnetic waves cause electrical resonance in GIS or ultra high voltage switchgear, and partial discharge can be found on the inside switchboard, as they are detected by UHF sensor. 2.3 The principles of detection and electromagnetic emissions by partial discharge Figure 1 shows a schematic of the occurrence of a partial discharge in GIS. Figure 1(a) shows partial discharge due to the fixed protrusion at the bottom of the internal of GIS, and generates a typical pulse wave, as shown in Fig. 1(b). If partial discharge occurs at the inside of GIS, transient current with a very fast rising time of tens of nano seconds flows, as shown in Fig. 1(b). 2.4 Measurement equipment Figures 2(a) and (b) are UHF sensors with 500~1,500 MHz frequency band, which are self-developed and applied to the field, and designed in a spiral [8]. These involved the self-developed UHF signal analysis equipment. They are able to amplify the ultra-wideband electromagnetic wave signal, and after filtering, to facilitate analysis, having the ability to change to the lowfrequency band. Figure 3 shows the internal block diagram of the analysis device, after weak signal input through the UHF sensor passed the LNA (low noise amplifier), which is designed by considering the stable gain, nonlinear characteristics and noise indices, designed to minimize unnecessary interference of the electromagnetic wave, by choosing the frequency band through the wide BPF (band pass filter). This signal is passed through the video detector, its frequency is 20 MHz ~30 MHz band, the scale has been reduced, and the processing hardware changed to be easy, then the signal input to the central processing unit of DSP through the A/D converter and to be treated. Figure 4 is a Tectronix TDS 5000 commercial oscilloscope for pattern analysis. The partial discharge signals are measured once by using the envelope mode capability, and measurement and storage during the 1,000 cycles are repeated. The analysis method used phase resolved partial discharge (PRPD).

Trans. Electr. Electron. Mater. 14(4) 211 (2013): J.-Y. Shin et al. 213 (a) (b) Fig. 3. Block diagram of the analysis device. Fig. 1. Partial discharge of GIS. (a) Fig. 4. Oscilloscope for pattern analysis. (b) Fig. 2. (a) UHF sensor and (b) antenna structure of the measurement equipment. 3. RESULTS AND DISCUSSION 3.1 Experimental results The following shows the data obtained from partial discharge diagnosis of the live wires of ultra high voltage by using UHF sensors. The UHF partial discharge measurement techniques were used for an ultra high voltage switchboard in approximately 200 large factories, in Gumi, Taiwan, and China. As a result, partial discharge signals were found at 15 places. Among them, after a power failure, it is found that the partial discharge signal was destroyed at discharge occurring in 8 places where abnormal places can be checked for by improvement work, such as a tightening check on the cable connection and the cable-head reinforcement. Figures 5, 6, 7 show the partial discharge signal obtained by the simulated results. 170 kv GIS mock-up was produced by the partial discharge of UHF, when partial discharge occurs. Figure 5 shows the floating discharge, Fig. 6 shows the corona discharge, and Fig. 7 shows the insulation voids discharge. In this paper, this signal is the standard signal, which is compared with the simulation signal and the measured signal in the field, and used to determine the discharge occurrence and type of discharge [9, 10]. The magnitude of the GIS voltage is different from the magnitude of voltage of ultra high voltage switchgear, but a partial discharge signal occurs, regardless of the magnitude of the voltage. Comparison and analysis of the electromagnetic wave radiation were possible, because the GIS is filled with SF 6, and the ultra high voltage switchgear air insulated are the same pattern in progress [11,12]. Figure 5 shows the partial discharge occurred by loosened metal bolts in the cable head of power equipment inside, and the part connected to the bus bar. When the signal pattern shown in Fig. 5 occurs [13,14], the metal and its connecting part should have been intensively checked. The measurement signals were successively measured and stored by PRPD method during the 1,000 cycles. The unit of the vertical axis is 100 mv/div, the unit of the horizontal axis is 2 ms/div, and the synchronous signal of 60 Hz and the measured signals are shown by nesting. Figure 6 shows the discharge pattern due to the applied voltage part or the extrinsic material of the metal surface or the protrusion. The abrasion state of the bus bar surface and the incoming voltage part should have been intensively checked. The measurement signals were successively measured, and stored by PRPD method during the 1,000 cycles. The unit of the vertical axis is 100 mv /div, the unit of the horizontal axis is 2 ms /div, and the synchronous signal of 60 Hz and the measured signals

214 Trans. Electr. Electron. Mater. 14(4) 211 (2013): J.-Y. Shin et al. Fig. 5. Partial discharge signals between each metal (floating discharge type). Fig. 8. Actual measurement of PD signals. Fig. 6. Partial discharge signals of protrusion (corona discharge type). Fig. 9. Re-measurements of PD signals. Fig. 7. Partial discharge signals of insulator defect (void discharge type). are shown by nesting. Figure 7 shows the discharge signals when the internal insulators in CT, PT and the supporting insulator have failure. This signal occurred on a crack in the internal void, surface damage, or contamination, during the insulator manufacturing and assembly process [13,14]. The signals were successively measured and stored by PRPD method during the 1,000 cycles. The CH3 at the top of the figure is the synchronous signals with applied voltage of 60 Hz. CH1 (medium) and CH2 (bottom) are signals measured by 2 UHF sensors. The unit of the vertical axis is 200 mv /div, and the unit of the horizontal axis is 2 ms /div. Figure 8 shows the partial discharge signals measured at the switchgear of a large factory in Gumi, which seems similar to Fig. 5. The amplitude of the discharge signal is approximately 500 mv, and occurred continuously. The sine wave in Fig. 8 is measured on 60 Hz phase for PRPD analysis. This signal is the standard signal, and shows the measured signals by accumulation during the 1,000 cycles. The unit of the vertical axis is 200 mv /div, the unit of the horizontal axis is 2 ms /div, and the synchronous signal of 60 Hz and the measured signals are shown by nesting. Here, the loosened bolt in the connection of the cable was found after power outage, so it was treated. It is confirmed that Fig. 10. Actual measurement of PD signals. Fig. 9 shows the cause of the partial discharge is eliminated by re-measurement. Figure 10 shows the measured data at the factory in Gumi, which is similar to Fig. 6. The partial discharge signal caused the small amount of the signals of 600 mv. The unit of the vertical axis is 200 mv /div, the unit of the horizontal axis is 2 ms/div, and the synchronous signal of 60 Hz and the measured signals are shown by nesting. Figure 11 shows that the metal connection part was checked, and the insulation was reinforced after power outage. It is confirmed that the discharge signal is destroyed, after re-measurement. The unit of the vertical axis is 200 mv /div, the unit of the horizontal axis is 2 ms /div, and the synchronous signal of 60 Hz and the measured signals are shown by nesting. Figure 12 shows the measured data at a large factory in Guang-

Trans. Electr. Electron. Mater. 14(4) 211 (2013): J.-Y. Shin et al. 215 The UHF sensor was used in the partial discharge diagnosis of the live wires of ultra high voltage panels. Simulating the actual discharge in GIS, based on the measured partial discharge signal, the discharge was measured at 200 locations in ultra high voltage switchboards. It is confirmed that the discharge signals of 15 locations in ultra high voltage switchboards are similar to the pattern of the measured partial discharge signals in GIS. Among them, after the power outage, the insulation was reinforced for 8 locations where the work is possible. After the voltage is applied again, it is confirmed through the measurement that the cause of partial discharge is destroyed. The types of the partial discharge signal of UHF, when partial discharge occurs in GIS, are floating discharge, corona discharge and the insulation voids discharge. The magnitude of GIS voltage is different from the magnitude of voltage of ultra high voltage switchgear, but a partial discharge signal occurs, regardless of the magnitude of the voltage. The GIS filled with SF 6 and the ultra high voltage switchgear air - insulated were taken as the same electromagnetic wave pattern in progress. The loosened bolt in the connection of the cable was tightened, the metal connection parts were checked, and the insulation was reinforced. CT, PT and supporting insulators were replaced. So they were treated. It is confirmed, after remeasurement, that the discharge signals are destroyed. 4. CONCLUSIONS Fig. 11. Actual measurement of PD signals (After 3 months). In this paper, we performed a test, in order to apply the partial discharge of a high-voltage distribution panel using an UHF sensor into live wire diagnostic technology. We identified signal patterns similar to partial discharge signals in GIS, and verified that it is possible to apply the signal interpretation methods for partial discharge in GIS. In the GIS, the fault location can be tracked by the UHF technique. However, we failed to assume the fault position, as the distribution system has a narrow structure, compared to GIS. In the case of GIS, a certain part of the components could be replaced through location tracking. Meanwhile, the high voltage distribution panel has small facilities, in comparison with GIS, so we had difficulty in tracking the discharge location via the UHF method. Nevertheless, we were able to classify the types of discharge faults, like floating discharge, corona discharge, void discharge, etc. With the data acquired by partial discharge measurement for a variety of places and data analysis, we will utilize the acquired data as fundamental information for the study on the management of a high-voltage distribution system that is effective in live wires, as well as risk assessment methods. REFERENCES Fig. 12. Actual measurement of PD signals. zhou, China. This is similar to Fig. 7, which shows the pattern of the partial discharge signal when there is any problem in the insulator. It confirmed that CT, PT and the supporting insulators were replaced, and the partial discharge is destroyed after re-measurement. The unit of the vertical axis is 200 mv /div, the unit of the horizontal axis is 2 ms /div, and the synchronous signal of 60 Hz and the measured signals are shown by nesting. 3.2 Discussion [1] A. G. Sellars, O. Farish, and B. F. Hampton, IEEE Trans. on Dielectr. Electr. Insul., 323 (1994) [DOI: http://dx.doi. org/10.1109/94.300265]. [2] B. F. Hampton and R. J. Meats, IEE Proceedings C, 137 (1988) [DOI: http://dx.doi.org/10.1049/ip-c.1988.0017]. [3] J. S. Pearson, O. Farish, B. F. Hampton, M. D. Judd, D. Templeton, B. M. Pryor, and I. M. Welch, IEEE Trans. Dielectr Electr. Insul., 893 (1995) [DOI: http://dx.doi.org/10.1109/94.469984]. [4] J. Y. Lim and J. Koo, J. Kor. Phys. Soc., 755 (2003). [5] M. D. Judd, O. Farish, B. F. Hampton, IEEE Trans. On DEI., 213 (1996). [6] N. Kock, B. Cornic, and R. Pietsch, IEEE Electr. Insul. Magazine, 20 (1996). [7] Koo, J. Yoon, J. Lim, Y. Chang, and Y. Kang, C, 335 (ISH. 2003). [8] Micro Wave Studio V5.0 (Computer Simulation Technology, 2004). [9] H. Doi, H. Muto, M. Fujii, and H. Kamei, Proc. IEE High Voltage Engineering Symposium, 70 (1999). [10] M. D. Judd, in Dielectric Windows Improve Sensitivity of Partial Discharge Detection at UHF (Conference Record of the 2000 IEEE International Symposium on Electrical Insulation, CA USA, 2000). [11] L. Yang, B. G. Stewart, A. J. Reid, M. D. Judd, and R. A. Fouracre, in Proceeding of the 14 th International Symposium on High Voltage Engineering (Tsinghua University, Beijing, 2005) p. 347. [12] S. Y. Jung, J. Y. Koo, Y. M. Jang, K. J. Park, and C. W. Kang, in Proceeding of the 14 th International Symposium on High Voltage Engineering (Tsinghua University, Beijing, 2005) p. 382. [13] Suwarno and T. Mizutani, in Proceeding of 2008 International Conference on Condition Monitoring and Diagnosis (North China Electric University, Beijing, 2008) p. 60. [14] S. G. Goo, H. J. Ju, K. J. Park, K. S. Han, and J. Y. Yoon, in Proceeding of 2008 International Conference on Condition Monitoring and Diagnosis (North China Electric University, Beijing, 2008) p. 64.