Study of monitoring system of a calibration laser for the itop detector at Belle II

Similar documents
High collection efficiency MCPs for photon counting detectors

A correlation-based timing calibration and diagnostic technique for fast digitizing ASICs

Timing and cross-talk properties of BURLE multi-channel MCP PMTs

Experiment 10. The Speed of Light c Introduction Apparatus

Particle ID in the Belle II Experiment

GAMMA-GAMMA CORRELATION Latest Revision: August 21, 2007

Seminar. BELLE II Particle Identification Detector and readout system. Andrej Seljak advisor: Prof. Samo Korpar October 2010

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Picosecond Time Analyzer Applications in...

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Electronic Readout System for Belle II Imaging Time of Propagation Detector

Performance of the MCP-PMTs of the TOP counter in the first beam operation of the Belle II experiment

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

TOP counter for Belle II - post installation R&Ds

itop System Overview Kurtis Nishimura University of Hawaii October 12, 2012 US Belle II Firmware Review

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan

Goal of the project. TPC operation. Raw data. Calibration

Updating APVDAQ, a software designed for testing APV25 Chips. Andreas Doblhammer (e )

Timing and cross-talk properties of Burle multi-channel MCP PMTs

arxiv: v2 [physics.ins-det] 17 Oct 2015

PMT Calibration in the XENON 1T Demonstrator. Abstract

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

Filters And Waveform Shaping

Considerations on the ICARUS read-out and on data compression

Traditional analog QDC chain and Digital Pulse Processing [1]

Testing the Electronics for the MicroBooNE Light Collection System

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

PCS-150 / PCI-200 High Speed Boxcar Modules

High granularity scintillating fiber trackers based on Silicon Photomultiplier

Time of Flight Measurement System using Time to Digital Converter (TDC7200)

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Characterizing a single photon detector

Supplemental Information

Calibration of Scintillator Tiles with SiPM Readout

Moderne Teilchendetektoren - Theorie und Praxis 2. Dr. Bernhard Ketzer Technische Universität München SS 2013

Sensing. Autonomous systems. Properties. Classification. Key requirement of autonomous systems. An AS should be connected to the outside world.

Simulation of Algorithms for Pulse Timing in FPGAs

Signal Processing in an Eddy Current Non-Destructive Testing System

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

Physics Experiment N -17. Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer

Preliminary simulation study of the front-end electronics for the central detector PMTs

Uniformity and Crosstalk in MultiAnode Photomultiplier Tubes

THE Hadronic Tile Calorimeter (TileCal) is the central

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

Nuclear Instruments and Methods in Physics Research A

Single-avalanche response mesurement method for MPGD detectors

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

Tektronix digital oscilloscope, BK Precision Function Generator, coaxial cables, breadboard, the crystal earpiece from your AM radio kit.

A Fast Waveform-Digitizing ASICbased DAQ for a Position & Time Sensing Large-Area Photo-Detector System

Frequency Scanned Interferometer Demonstration System

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

A high-performance, low-cost, leading edge discriminator

Resonance in Circuits

CAEN Tools for Discovery

DETECTING THE RATIO OF I AC

Total Absorption Dual Readout Calorimetry R&D

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Bipolar Junction Transistor (BJT)

The LUCID-2 Detector RICHARD SOLUK, UNIVERSITY OF ALBERTA FOR THE ATLAS- LUCID GROUP

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Notes on Noise Reduction

The Trigger System of the MEG Experiment

ORTEC. Time-to-Amplitude Converters and Time Calibrator. Choosing the Right TAC. Timing with TACs

Shape-based event pileup separation in Troitsk nu-mass experiment

CHAPTER 11 HPD (Hybrid Photo-Detector)

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification

Timing accuracy of the GEO 600 data acquisition system

Control of Noise and Background in Scientific CMOS Technology

SHM-180 Eight Channel Sample & Hold Module

MuLan Experiment Progress Report

The 34th International Physics Olympiad

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Deliverable Report. CERN pixel beam telescope for the PS

Frequency Scanned Interferometer Demonstration System

Pixel Response Effects on CCD Camera Gain Calibration

EKA Laboratory Muon Lifetime Experiment Instructions. October 2006

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University

Physics 342 Laboratory. Scattering of Photons from Free Electrons: Compton Scattering

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 22.

A BaF2 calorimeter for Mu2e-II

A 4 Channel Waveform Sampling ASIC in 130 nm CMOS

UNIT-3. Electronic Measurements & Instrumentation

Laboratory 1: Uncertainty Analysis

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

Photons and solid state detection

PoS(ICRC2017)449. First results from the AugerPrime engineering array

8.2 Common Forms of Noise

DATA SHEET THICK FILM CHIP RESISTORS Introduction

Vertical Tests of ILC Cavities and Detection of X-Rays from Field Emission

Class #9: Experiment Diodes Part II: LEDs

Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization 1-1 Oho, Tsukuba, Ibaraki , Japan

PoS(TWEPP-17)025. ASICs and Readout System for a multi Mpixel single photon UV imaging detector capable of space applications

The steeper the phase shift as a function of frequency φ(ω) the more stable the frequency of oscillation

Intermediate and Advanced Labs PHY3802L/PHY4822L

Scintillators as an external trigger for cathode strip chambers

LINEAR IC APPLICATIONS

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

Transcription:

Università degli Studi di Padova Dipartimento di Fisica e Astronomia G. Galilei Corso di laurea in Fisica Tesi di Laurea Study of monitoring system of a calibration laser for the itop detector at Belle II Relatore: Dott. Stefano Lacaprara Correlatore: Dott. Alessandro Mordà Laureando: Gabriele Labanca Matricola: 169556 Anno Accademico 215/216

Contents 1 Introduction 2 1.1 itop................................. 2 Calibration system...................... 2 2 Apparatus and data acquisition 3 2.1 Device schematics.......................... 3 2.2 Signal features............................ 3 Shape............................. 4 Background.......................... 4 Trigger and time of arrival.................. 5 3 Signal analysis 7 Datasets............................ 7 Variables........................... 7 Analysis............................ 8 3.1 Amplitude and integral distributions................ 9 3.1.1 Amplitude distribution.................... 9 3.1.2 Integral distribution..................... 9 3.1.3 Discussion on the methods................. 11 Uncertainties......................... 11 Correlations.......................... 11 3.2 Fit the signal............................. 14 3.2.1 Strategies........................... 14 3.2.2 Results............................ 14 Compare the strategies................... 14 χ 2 distribution........................ 15 Parameters distribution: signal events........... 17 3.2.3 Discussion on time of arrival................ 19 3.3 Discussion on variables........................ 21 3.4 Real case............................... 21 3.5 Light yield estimation........................ 23 Fit the integral........................ 23 Fit the distribution...................... 25 4 Conclusions 27 Further developements.................... 27 1

1 Introduction The work presented in this thesis concerns a study on a calibration system to be used by the itop ( Time Of Propagation ) detector in the Belle II experiment ([1]) at superkekb (upgrades of Belle and KEKB, respectively), managed by KEK, the Japanese High-Energy Accelerator Research Organization. The experiment is currently under installation at Tsukuba (Japan), and is scheduled for first data taking in late 218. Figure 1: (Left) The SuperKEKB accelerator, showing the position of Belle II; (Right) The Belle II detector 1.1 itop The itop detector (Figure 2; Technical Design Report, [1]) will be used to identify charged particles, π and K, and consists of 16 quartz crystal bars surrounding the interaction region arranged in a cylindrical shape. At one end of the bars there is an array of 16 2 MCP-PMT (Micro Channel Plate - Photo- Multiplier Tubes), at the other end there is a mirror. When a charged particle crosses a bar, it emits Cherenkov light, which is transmitted by internal reflection to the ends of the bar, where photons hit the photodetector. The angle at which the light is emitted depends on the β of the particle; by measuring the curvature of the track of the particle in the magnetic field it is possible to compute its momentum: knowing the momentum and the β is enough to separate particles with different masses such as π and K. The photodetector records a pattern as a function of position and time which depends on the β of crossing particles. Calibration system A calibration system for the itop uses a laser, whose characteristic emission is to be known and whose light is splitted and reaches 2

Figure 2: itop schematics: the photodetector is highlighted. Image from the Technical Design Report [1] through optical fibers all the photodetectors in the array of each bar, to check if they keep reacting the same way over time: this requires a monitoring system to measure the emission of the laser in different conditions: the resulting parameter is its yield, whose stability over time and exposure to temperature is to be studied.. 2 Apparatus and data acquisition The apparatus and the features of the signal are here exposed. In particular, an extimate of the background is computed. 2.1 Device schematics The laser schematics is reported in Figure 3: for the monitoring of the laser a photodiode is used instead of a MCP-PMT. The photodiode can be modeled as a capacitor in series with a resistor: when a photon goes through the photodiode, it creates electron-hole pairs which reach to the terminals of the capacitor, making its charge drop by an amount proportional to the energy deposited. As a consequence, the voltage decrement is also proportional to the amount of energy deposit. An electronic device (DAQ in Figure 3) reads the voltage value and writes it in a file, which is analyzed in the present work, starting from a preliminar analysis performed by the research team, displayed in this section. The trigger signal is produced by the laser at a fixed t prior of the actual light emission and allows a temporal comparison between the signal shapes. 2.2 Signal features The signals (trigger and photon) consist in 124 bins representing the time: each bin corresponds to 2ps and stores the value of the measured voltage amplitude. 3

Figure 3: Laser schematics: the laser emitter works at 1kHz, shooting short pulses and its attenuation is tunable; the photon emission is trasmitted through optical fibers to the photodetector, whose signal is then amplified before reaching the data acquisition devices; meanwhile trigger signal is sent directly to the DAQ (data acquisition, namely the electronics that acquires the two signals and save them in a file) through a parallel channel Laser emitter photon emission PMT Amplifier trigger signal Shape Figure 4 shows some typical events (from top to bottom): a signal without evident peaks, corresponding to zero photons; a negative peak exponentially decaying, corresponding to a one-photon detection; a peak with a larger amplitude, due to the detection of several photons at the same time; a not very clear event, featuring two consecutive peaks. A possible explanation is the assumption of internal reflections, causing some delay for the arrival of the two photons, or the effect is probably simply due to noise effects. From now on the generic acquisitions will be called signals, while the acquisitions of photons will be called events. Background In the following the voltage will be considered as the variation from the voltage baseline, namely the average value of the voltage before the arrival of a photon. For each signal this pedestal value has been evaluated by averaging the amplitude over the bins in the interval [1,11] which are consecutive and in a range near the signal region, but clearly separated from it. The histogram in (Figure 5) shows the distribution of the background estimate: as expected, it has a 4

Figure 4: Typical events: on the left, the trigger signal; on the right, the photon signal. From top to bottom: triggered background, one peak, one higher peak (background scaled down), one double peak [x-axis: time(bins); y-axis: signal amplitude] [bin=2ps] 3 25 2 15 1 5 3 25 2 15 1 5 3 25 2 15 1 5 3 25 2 15 1 5 2 4 6 8 1 2 4 6 8 1 2 4 6 8 1 2 4 6 8 1 128 126 124 122 2 4 6 8 1 125 12 115 12 1 8 2 4 6 8 1 6 2 4 6 8 1 13 12 11 1 2 4 6 8 1 central peak. This estimate has been used as a baseline for signal: the peak for zero-photon signal is centered in zero. The triggered signals are considered photons when their maximum amplitude is bigger than 8 and their integral over 4 bins is bigger than 4, background otherwise; this choice has been done considering Figure 12: being the the width of the noise distribution 1, the limit is well over 3σ. It is important to notice that the background signals are not just noise, since they represent the of zero-photon component of the collected events. Trigger and time of arrival The trigger signal plays an important role: as shown in Figure 6, subtracting the trigger time the time of arrival (defined as the bin of the minimum) of signals is distributed around peaks: the first and higher (from now on named principal ) is followed by some others ( secondary ), progressively decreasing; there is another peak around the 86th bin ( tail ). Their nature will be discussed in 3.2.3 5

Figure 5: Estimate of the background 14 12 Entries 95923 Mean 1263 Std Dev 8.7 1 8 6 4 2 123 124 125 126 127 128 129 13 background value Figure 6: Delay of the time of arrival with respect to the trigger time: there are some steep peaks around 3 ( principal, secondary ) and a block around 85 ( tail ) [x-axis: time (bins); y-axis: ] 6 5 4 3 2 1 2 2 4 6 8 1 time of arrival (bins) 6

3 Signal analysis Datasets The thesis focuses on building an algorithm to extract a variable descriptive of the emission. To do so, two datasets have been used: test, with high attenuation, suppressing the photon emission (Figure 7); real, with lower attenuation, close to the working conditions (Figure 8). Figure 7: 2D plot of all events superimposed (high attenuation): the background it is clearly visible and two or three peaks can be identified, their intensity decreasing when the amplitude is higher [bin=2ps] 6 Entries 9.822515e+7 35 4 3 signal amplitude 2 25 2 2 4 15 6 1 8 5 1 12 Variables 2 4 6 time(bins) 8 1 12 Three possible choices are discussed: amplitude in a bin; integral of the signal; integral of a function fitting the signal. Finally, the chosen one, the integral of the signal, is used to describe the light yield of the laser in the two datasets, by counting the of arrival of n-photons (n from -noise- to the maximum number of photons seen). This distribution, in principle Poissonian (possibly plus instrumental effects), is sensitive to the light yield. 7

Figure 8: 2D graph of all events superimposed (lower attenuation): the background is less substantial and more stripes are visible [bin = 2ps] 6 Entries 1.2764e+8 4 3 2 signal amplitude 25 2 2 4 15 6 1 8 5 1 12 2 4 6 time (bins) 8 1 12 Analysis In order to estimate the fraction of events wn corresponding to the detection of n photons, three variables have been considered: the amplitude in a fixed bin ( 3.1.1), the integral of the signal ( 3.1.2) and the integral of the function which fits the signal ( 3.2). The integral of the signal has then been chosen and fitted with a sum of Gaussian functions ( 3.5): ideally the fractional weights of these functions are expected to follow a Poissonian distribution, but some instrumental effects may be present. 8

3.1 Amplitude and integral distributions In order to describe quantitatively the signal, two kinds of variables are considered: local: evaluated considering the amplitude in only one selected bin; they are simpler to evaluate, but more affected by noise effects; global: evaluated over a range of bins; they are less affected by noise effect. The maximum amplitude and the amplitude at a fixed bin are in the first category ( 3.1.1), while the integral is in the second ( 3.1.2). 3.1.1 Amplitude distribution A first variable considered for the characterization of the signal is the maximum absolute value of amplitude: its distribution is shown in Figure 9. This variable, however, is biased by construction (being a maximum): this is clearly seen for the first peak, which should be centered in zero. A less biased variable is the amplitude at a fixed bin: the 292nd one has been chosen, since is the central value of the principal peak (Figure 6). There are issues expected using this variable: first, using a fixed bin does not detect the maximum absolute value of the amplitude if the arrival time is different (which is the case for many events); furthermore it is very sensible to noise. Its distribution is presented in Figure 1: the shape is more regular than the one of maximum amplitude. 3.1.2 Integral distribution A method to refine the analisys is to compute a simple integral of the signal shape, namely a sum of the amplitudes, over 4 bins after the arrival of the signal. The length of integration has been chosen noticing that the decay length of almost all the signals is 4 bins; varying this length does not affect the results substantially. It can be seen, from Figure 11, that the distribution is more similar to the one of the amplitude, and features the advantage that more peaks are visible. The improvements concern primarily the number of peaks clearly identifiable, which increased up to 6-7. Looking at the peak of the background, a shift towards lower number is evident: this can be due to a drift of the baseline along the bins. This however does not affect the analysis, since the interesting quantity is the distance between the peaks. 9

Figure 9: Maximum amplitude histogram: a shift of the peak in zero is visible 22 2 18 16 14 12 1 8 6 4 2 1 2 3 4 5 6 7 8 minimum Figure 1: Amplitude at a fixed bin: the highest peak is at zero, with the other progressively decreasing 35 3 25 2 15 1 5 1 1 2 3 4 5 6 amplitude at a fixed bin 1

Figure 11: Histogram of the integral over 4 bins: the peaks are shifted, this can be due to a drift in the baseline 14 12 1 8 6 4 2 1 2 4 6 8 1 integral value 3 3.1.3 Discussion on the methods Uncertainties To compare the efficacy of these differents methods, the the peak corresponding to the detection of three photon is fitted with a Gaussian function and its uncertainty is computed and compared in Table 1: the values have been normalized on the distance between this peak and the previous one. It is evident that the distributions of the amplitude at a fixed bin and the integral describe more separated peaks. Table 1: The uncertainties on the three-photons peak, normalized on the distance between this peak and the previous, compared for the distributions of maximum amplitude, amplitude at a fixed bin, and integral σ µ maximum amplitude 41% ± 2% amplitude at fixed bin 27.% ±.7% integral 27.2% ±.4% Correlations Evaluating the correlation between these variables helps understanding how well they describe the emission. The correlation between the 11

amplitudes ( 3.1.1) and the integral ( 3.1.2) is plotted in Figure 12 and Figure 13: they describe the same phenomenon, but it is evident that the amplitude at a fixed bin fails to classify a big part of the events. In particular, from Figure 12 a discrimination criterion between background and signal can be defined, considering background the events in the left-bottom peak. The only variable being neatly distributed and well correlated to the number of photons detected is the integral as a sum over the bins. This one is thus the best variable according to the analysis done in this section. 12

Figure 12: Minimum as a function of direct integral: the correlation is strong; the events with maximum smaller than 8 and integral smaller than 4 are considered background 22 6 5 2 18 16 minimum 4 3 14 12 1 2 1 2 4 6 8 integral value 8 6 4 2 Figure 13: Amplitude at bin 29 as a function of direct integral: the correlation is not good 7 6 22 2 18 amplitude at 292nd bin 5 4 3 2 16 14 12 1 8 6 1 1 2 3 4 5 6 7 8 9 integral value 4 2 13

3.2 Fit the signal The signals have been fitted one by one, then the integral of the fitting function has been evaluated and used as another descriptive variable. This is similar to the direct integral, but possibly even less sensible to background oscillations. 3.2.1 Strategies The signals have been fitted one by one, with different methods, with the purpose of integrating the fitting function, having another descriptive variable, analogous to the simple integral, but possibly less dependent on the noise. The function chosen to fit the signal is the following (dimension proportional to a voltage): f(x) = e A kx where x is the bin index, in units of 2ps. The methods differ in the way the points to fit are chosen: simple points 5 points with coordinates: (x + n, A(x + n )) being x the position of the aboslute minimum of the signal amplitude A, a fixed distance between two subsequent points, equal to 1 bins, and A(x n ) the amplitude value at the bin x n. points with uncertainties 5 points with the same values as the previous case for the x and y coordinates with in addition an associated error to both of them. The error on the y value is given as the uncertainty on the background mean. averaged points 5 points with the central value of y given by the average over the 5 surrounding bins around the central one (i.e. n central ± 2) and associated error on y given by the uncertainty on the background mean. The choice of the average is done in order to reduce the amplitude fluctuations due to the electric noise affecting the y coordinate central value; the estimated error on the y value may represent, with this choice, a conservative estimation. Nevertheless, it will be shown that the obtained χ 2 distribution of the fit will assume reasonable values. 3.2.2 Results Compare the strategies The efficiency ɛ is defined as the number of converged fit over the number of attempts; analogous efficiencies can be defined separately for photon (ɛ φ ) and background (ɛ B ) triggers. The efficiencies as well as the standard deviation of a Gaussian fit of the first peak of the distribution (σ) are reported in Table 2. 14

Table 2: The efficiencies, as defined in 3.2.2, as well as the Gaussian error on the first peak, are reported for all the strategies of interpolation simple points uncertainties averaged points ɛ.921 ±.3.967 ±.3.959 ±.3 ɛ φ.9995 ±.4.996 ±.4.994 ±.4 ɛ B.78 ±.5.935 ±.5.925 ±.5 σ 167 ± 18 1684 ± 14 1691 ± 12 Since ɛ B is much lower for the first strategy and the number of zero photon events is of interest, the first strategy has been excluded. The performances of the others are similar, but the last one should be less dependent on noise oscillations, since the points are averaged, and is thus the chosen one. The distribution of the integrals of the fitting functions for this method is shown in Figure 14. The events for which the fit attempt did not converge have been then removed from the analysis. χ 2 distribution The χ 2 distribution of the fit for the chosen method is shown in Figure 15: there are 5 points to fit and two parameters in the fitting function, so there are 48 degrees of freedom. The mean is high, but the higher peak corresponds to a reasonable value (near 5). Since the results are good, using a less conservative estimate of the uncertainty wouldn t be accettable.. 15

Figure 14: Distribution of the integral of the fitting function: the first peak (cut due to the evaluation process) is background, as defined in 2.2, while the others are photon events 6 5 all events photon events background 4 3 2 1 1 2 3 4 5 6 7 8 integral value Figure 15: The χ 2 function: points with error, converged fit. For the distinction between photon events and background see 2.2. Since there are 48 degrees of freedom, the peak around 5 is a mildly good result 1 8 all events photon events background 6 4 2 1 2 3 4 5 6 7 8 9 1 16

Parameters distribution: signal events The parameter k is expected to be the same for all the events, since it depends on the RC circuit of the photodiode, and in Figure 16 the results agree with this hypothesis. The presence of a shoulder in the left part of the distribution could be due to the drift in the baseline discussed before. Since k is fixed, A must vary depending of the type of event and looking at Figure 17 a distribution analogous to the one of amplitude can be recognised. Since A is the constant term in the exponent, it is proportional to ln n (being n the maximum amplitude of the signal in units of the one-photon amplitude); for that reason the distances between two subsequent peaks are given by ln n+1 n. The same pattern is visible in Figure 18: looking only at the photon events some stripes are present, which correspond to the distributions of the amplitude at 292nd bin and of the integral. Figure 16: The parameter k and filters: photon events ( 2.2). Only converged fits considered. As expected, there is only one peak 25 2 15 1 5.5.5.1.15 k value 17

Figure 17: The parameter A and filters: photon events ( 2.2). Only converged fits considered. A pattern similar to the amplitude peaks is evident 6 5 4 3 2 1 3 4 5 6 7 A value Figure 18: The parameter k as a function of A filtered for photon events ( 2.2). Only converged fits considered. A pattern similar to the amplitude peaks is evident 12.15 1.1 8 A value.5 6 4.5 2 1 2 3 4 5 6 7 8 k value 18

3.2.3 Discussion on time of arrival Filtering the time of arrival with maximum amplitude it can be seen that the tail peak has only background (Figure 19), while the other two contain photon events. Figure 19: Time of minimum filtered for photon events and background events ( 2.2). It is clear that the tail peak consist almost only of background events 6 5 all events photon events background 4 3 2 1 2 2 4 6 8 1 time of arrival Concerning the primary and secondary peaks, Figure 2 and Figure 21 show the distribution of k as a function of A, presenting a shape analogous to to the photon events seen in Figure 18. This is sufficient to explain the nature of these peaks, at least considering the goals of the thesis. Probably a better choice to define the time of arrival would have been the position of the step falling front, rather than the position of the minimum. However, this does not affect the results presented in this work. 19

Figure 2: The fit parameter k as a function of A, for events with arrival time in the primary peak: the shape resembles the typical signals.2 12 1.15 8 k value.1 6.5 4 2 3 4 5 6 7 A value Figure 21: The fit parameter k as a function of A, for events with arrival time in the secondary peak: the shape resembles the typical signals.12.1 35 3 25 k value.8.6 2 15.4 1.2 5 3.5 4 4.5 5 5.5 6 6.5 7 7.5 A value 2

po Entries 95923 Mean x 1.377e+4 Mean y 74.34 Std Dev x 1.527e+4 Std Dev y 12.1 3.3 Discussion on variables At this point, a choice has to be done, between the simple amplitude, the integral as a sum, or the integral of the fitting function (the more complete method, with averaged points and errors, is used). The first thing to notice is the disagreement between the simple amplitude and the other two: from Figure 13, as seen in 3.1.3 and Figure 22 is evident that the variables behave differently. Instead, the two strategies of integration agree very well (Figure 23). The integral as a sum over bins is chosen, because it is easier to compute and indipendent on the method of fit used. Figure 22: Amplitude at bin 29 cross-plotted with integral of fitting function: a strong disagreement is noticeable 1 8 6 amplitude at 29th bin 6 4 2 5 4 3 2 1 2 1 2 3 4 5 6 integral of fitting function 3.4 Real case After the definition of the method, another acquisition has been analyzed, this time with attenuation set at a value similar to that expected in the Belle II experiment, to compare and check the results. In Figure 8, where all the events in the set are plotted, it can be noticed an increased fraction of events at higher amplitudes, as expected. The results of the different methods of integration are summarized in Figure 24 (the simple sum over bins) and Figure 25 (the integral of the fitting function, with errors and averaged points). 21

Figure 23: Integral as sum over bins cross-plotted with integral of fitting function: the agreement is good 16 3 1 6 14 5 simple integral 12 1 8 6 4 2 hea_integral_bins_integral_4 Entries 95923 Mean x 2.32e+4 Mean y 2.25e+4 Std Dev x 1.851e+4 Std Dev y 1.861e+4 4 3 2 1 2 4 6 8 1 12 14 16 integral of the fitting function 3 1 Figure 24: Direct integral histogram, real dataset 18 16 14 12 1 8 6 4 2 3 1 2 4 6 8 1 12 14 16 18 integral value 22

Figure 25: Integral of fit histogram, real dataset: the first peak (cut because of the evaluation process) is background, while the others are photon events 8 all events 7 6 photon events background events 5 4 3 2 1 3 1 2 4 6 8 1 12 14 16 18 integral value 3.5 Light yield estimation Fit the integral The direct integral has been chosen as the optimal method to analyze each trigger, for the reason that leads to the same results of the integral of the fitting function, however being much easier to compute and independent on errors made during fit. Another fact leading to this conclusion is that the integral of the fitting function doesn t allow to use the peak in zero, despite it being the bigger. Once the optimal method to analyze each trigger has been defined, the next step is to look at the distribution of the number of photons detected by the photodiode, which depends on the laser light yield. In order to describe the distribution, a fit is performed. The function chosen to fit the integral distribution is a sum of Gaussian distributions, each centered at points whose distance from one another is fixed to be the same. The peak at zero needed an exception, though: having the tails bigger than those of a normal Gaussian, it has been fitted with two Gaussian functions. The resulting function is ) F (x) = w (G a (x) C + G b (x) (1 C) + G i (x) w i i=1 where the index refers to the peak at zero photons, and the others follow; the Gaussian functions are written as G i while their weigths are written as w i ; C is 23

a constant used to preserve the normalization; G a and G b are the two Gaussian functions used for the peak at zero. The range has been limited at the seventh photon peak for the case with test attenuation (Figure 26) and at the tenth for the case with real attenuation (Figure 27). Each figure shows the true function and the same in logarithmic scale, to better see the deviations from the data; the pull distribution follows. Most of the pulls are less than 3σ, showing that the result of the fit is good. Figure 26: Fit of the direct integral distribution, test attenuation: from the top, the interpolation, in normal and logaritihmic scale, pull distribution 6 4 2 2 4 6 3 1 2 1 1 2 4 6 pull value 4 2 2 4 2 4 6 24

Figure 27: Fit of the direct integral distribution, real attenuation: from the top, the interpolation, in normal and logarithmic scale, pull distribution 3 2 1 1 2 4 6 8 1 3 3 1 2 1 1 1 2 4 6 8 1 3 pull value 5 5 1 2 4 6 8 1 3 Fit the distribution Finally, an attempt has been done to fit the distribution of the set (number of photons,weight): in Figure 28 and Figure 29 the blue line is a Poissonian function, while the red line is respectively an exponential and a Gaussian function. It is evident that the distribution isn t purely Poissonian. 25

Figure 28: Fit of the direct integral distribution, attenuation = 1%; red line: exponential function (parameters in the panel); blue line: Poissonian function (mean =.1).45.4.35 χ 2 / ndf 3.58 / 4 Constant.8375 ±.7649 Slope.5136 ±.338.3.25.2.15.1.5 1 2 3 4 5 6 Figure 29: Fit of the direct integral distribution, attenuation = 8%; red line: Gaussian function (parameters in the panel); blue line: Poissonian function (mean = 3).24.22.2 χ 2 / ndf 211.2 / 9 Constant.1139 ±.8239 Mean 2.95 ±.279 Sigma 2.856 ±.3168.18.16.14.12.1.8.6.4.2 1 2 3 4 5 6 7 26

4 Conclusions The analysis has found a parameter whose distribution can represent the signal emitted by the laser: the simple integral over 4 bins starting from the 29th bin of the array of data (where most of the events have minimum) allows a simple and fast computation. The fit with Gaussian functions works, as expected, but the distribution followed by the photon emission is not simply Poissonian. Further developements An attempt to fit the photon distribution can be done with a convolution of a Poissonian with a Gaussian, so that the efficiency of the detector is taken into account too. Further steps will be analyzing the behaviour of the parameters of this function under different conditions: not only varying the attenuation, but also the time of acquisition, the amplification and ambient parameters such as temperature. 27

Bibliography References [1] Z. Doležal, S. Uno Belle II Technical Design Report KEK Report 21-1, October 21 [2] Belle II project site https://www.belle2.org/ [3] SuperKEKB project site http://www-superkekb.kek.jp/ [4] K. Inami, et al. Nuclear Instruments and Methods in Physics Research, Section A, 766 (214), p. 5 [5] F. Bianchi et al. The laser calibration system of the TOP detector BelleII note 41, Mar. 15, 215 [6] Advanced Laser Diode Systems Picosecond Diode Laser - PiLas Manual 28