Fisher LCP100 Local Control Panel

Similar documents
IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro-Pneumatic Transducers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Fisher 4200 Series Electronic Position Transmitters

Range Spring, Bias Spring, and Spring Retainer/ Spacer Selection for Fisher 3570 Pneumatic Valve Positioners

IP26 Series Current to Pneumatic Converter

Customer Drawings Product Selection

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

Process display RIA 261

DPharp Differential Pressure and Pressure Transmitters

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Rosemount 5408 and 5408:SIS Level Transmitters

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

ATEX Installation Drawings and Instructions

Technical Data. General specifications. Rated operating distance s n 3 mm

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

INSTRUCTION MANUAL (ATEX / IECEx)

OPTITEMP TT 10 C/R Technical Datasheet

Rosemount 148 Temperature Transmitter

KMS-2 Exia Magnetostrictive Level Transmitter

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Rosemount 148 Temperature Transmitter

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operating Manual. isolate501

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

OPTIWAVE 7300 C Supplementary instructions

Rosemount 3101, 3102, and 3105

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Binary Output without Power Supply Series 9176

Installation guide 873 SmartRadar Control Unit & Antenna Unit

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Precision Junction Boxes

Isolators A3/1.

Isolators A3/1. Vibration Transducer Supply Unit Series

Emerson (Appleton Group ATX)

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Installation guide 877 FDI Field Display & Interface

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Precision Junction Boxes

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Binary Output Series 9175

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

FLEX Ex Power Supplies

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Installation guide 971 SmartRadar LTi

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Cyclops User s Manual

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

KMS-2 Exd Magnetostrictive Level Transmitter

Loop Powered Indicator

Analog Universal Module HART for Zone 2 Series 9468/33

Power supply CP-D 24/4.2 Primary switch mode power supply

Installation & Operating Manual. iwap202

Rosemount 148 Temperature Transmitter

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

FOUNDATION Fieldbus Junction Box

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply CP-D 24/1.3

Industrial Pressure Transducers

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

R88000 T (including ATEX)

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Temperature Input Module for Zone 1 Series 9482/32

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

3500/64M Dynamic Pressure Monitor

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Single-Channel Safety Barriers Series 9001

CERTIFICATE OF COMPLIANCE

SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

Pressure transmitter AKS 32 and AKS 33

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

Submersible pressure sensor For superior applications Model LF-1

Digital Input Output Module for Zone 2 Series 9470/33

DeltaV SIS Logic Solver

Rosemount 148 Temperature Transmitter

Transcription:

Instruction Manual Local Control Panel Fisher Local Control Panel Contents Introduction... Scope of Manual... Description... Specifications... Educational Services... Installation... 5 Hazardous Area Classifications and Special Instructions for Safe Use and Installation in Hazardous Areas... 5 Mounting... 5 Electrical Connections... 5 Pre Setup Testing... 4 Setup... 5 Principle of Operation... 5 Maintenance... 6 Troubleshooting... 6 Parts Ordering... 7 Parts List... 7 Common Parts... 7 Figure. Fisher Local Control Panel, with FIELDVUE DVC600 SIS Digital Valve Controller and Bettis Actuator X047 Introduction Scope of Manual This instruction manual includes installation and maintenance information for the Fisher local control panel (figure ). This device is used with Fisher FIELDVUE instruments in Safety Instrumented Systems (SIS). Refer to the DVC600 SIS Digital Valve Controllers for Safety Instrumented System (SIS) Solutions instruction manual (D03557X0) or the DVC6000 SIS Digital Valve Controllers for Safety Instrumented System (SIS) Solutions instruction manual (D0330X0) for additional information. Unless otherwise noted, the information in this instruction manual applies to both DVC600 SIS and DVC6000 SIS digital valve controllers. For simplicity, the DVC600 SIS model name will be used throughout. www.fisher.com

Local Control Panel Instruction Manual Do not install, operate, or maintain an local control panel without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all of the contents of this manual, includingall safety cautions and warnings. If you have any questions about these instructions, contact your Emerson sales office or Local Business Partner. Description The local control panel is used with the HART communicating DVC600 SIS digital valve controller. This panel is used to manually open and close a safety shutdown valve. The also provides a manual reset feature as well as a button for initiating a partial stroke test. Specifications Typical specifications for the local control panel are shown in table. Educational Services For information on available courses contact: Emerson Automation Solutions Educational Services - Registration Phone: +-64-754-377 or +-800-338-858 e mail: education@emerson.com emerson.com/fishervalvetraining

Instruction Manual Local Control Panel Table. Specifications Power Options (switch selectable) External: 4 VDC +/- 0% @ 50 ma maximum continuous current (00 ma maximum inrush) Loop: 8 0 ma ( and DVC600 SIS combined) Power Consumption External:.3 W max continuous Loop (Point-to-Point): 0.04 W max continuous Loop (Multi-Drop): 0.6 W max continuous Temperature Limits () -40 to 65 C (-40 to 49 F) Maximum distance between and DVC600 SIS digital valve controller Cable length is limited by maximum cable capacitance of 00,000 pf (). Typical 34 meters (030 feet) with 8 AWG shielded Audio, Control and Instrumentation Cable. Electrical Classification CSA (C/US) AEx ia IIB T4 Ga (3) Zone 0,, AEx e mb [ib] IIC T4 Gb Zone, AEx ic IIC T4 Gc Zone Class I Division Groups ABCD T4 ATEX Ex ia IIB T4 Ga (3) Zone 0,, Ex e mb [ib] IIC T4 Gb Zone, Ex ic IIC T4 Gc Zone IECEx Ex ia IIB T4 Ga (3) Zone 0,, Ex e mb [ib] IIC T4 Gb Zone, Ex ic IIC T4 Gc Zone T7 C Db Zone, CUTR Ex em[ib] IIC Zone, Ex ic IIC Zone Electrical Housing IP66 Electromagnetic Interference (EMI) Meets EN 636-:03 Immunity Industrial locations per Table of EN 636- Standard. Performance is shown in table below. Emissions Class A ISM equipment rating: Group, Class A Connections Conduit: 3/4 NPT or M0 Wiring 4 to 6 AWG Torque Specifications Wiring terminals: 0.5 N m (4.5 in lbs) Electrical Installation Wire connections are polarity sensitive Compatibility DVC600 SIS with Firmware revision 3 or later DVC6000 SIS with Firmware revision 7 or later Installation Orientation Wiring entrance must be facing down Dimensions 53. mm (0 inches) long by 09.5 mm (4.3 inches) wide by 7.8 mm 5 inches) deep. See figure. Construction Materials Housing material: filled polyester Approximate Weight. kg (4.9 lb). The pressure/temperature limits in this document and any applicable standard or code limitation should not be exceeded.. DVC6000 SIS: Cable length is limited by maximum cable capacitance of 8000 pf. 3. LOOP Powered only. 3

Local Control Panel Instruction Manual Table. Electromagnetic Immunity Performance Criteria Port Phenomenon Basic Standard Test Level Performance Criteria () Electrostatic discharge (ESD) IEC 6000 4 4 kv contact 8 kv air A Enclosure 80 to 000 MHz @ 0V/m with khz AM at 80% Radiated EM field IEC 6000 4 3 400 to 000 MHz @ 3V/m with khz AM at 80% 000 to 700 MHz @ V/m with khz AM at 80% A Burst (fast transients) IEC 6000 4 4 kv, I/O lines kv, DC power lines A I/O signal/control kv, I/O lines Surge IEC 6000 4 5 kv, DC power lines) A Conducted RF IEC 6000 4 6 50 khz to 80 MHz at 3 Vrms with khz AM at 80% A Specification limit = ±% of span. A = No degradation during testing. B = Temporary degradation during testing, but is self recovering. Figure. Fisher Local Control Panel Dimensions 94 (7.6) 57 (0.) 9 (5.) 94 (3.7) E077 0 (4.3) mm (INCH) 4

Instruction Manual Local Control Panel Installation WARNING Electrostatic charge hazard. Do not rub or clean the with solvents if a flammable vapor is present. To do so could result in an explosion. Note Direct all wiring to the left side inside the LPC00 compartment, away from the buttons. Hazardous Area Classifications and Special Instructions for Safe Use and Installation in Hazardous Locations Refer to the following instruction manual supplements for approval information. CSA (C/US) Hazardous Area Approvals - Local Control Panel (D0436X0) ATEX Hazardous Area Approvals - DVC000 Digital Valve Controllers (D0437X0) IECEx Hazardous Area Approvals - DVC000 Digital Valve Controllers (D0438X0) All documents are available from your Emerson sales office, Local Business Partner, or Fisher.com. Contact your Emerson sales office or Local Business Partner for all other approval/certification information. Mounting Refer to figure for dimensional information. The local control panel has four (4) mounting holes for on site mounting of the device. The must be installed so that the wiring connections are on the bottom to prevent accumulation of moisture inside the box. Electrical Connections WARNING Select wiring and/or cable glands that are rated for the environment of use (such as hazardous location, ingress protection, and temperature). Failure to use properly rated wiring and/or cable glands can result in personal injury or property damage from fire or explosion. Wiring connections must be in accordance with local, regional, and national codes for any given hazardous area approval. Failure to follow the local, regional, and national codes could result in personal injury or property damage from fire or explosion. Refer to the appropriate wiring diagram, as defined in table 3, based on your protection method and installation requirements. Also refer to figure 4 for switch setting, terminal connections, and label details and information, as well as DVC600 SIS terminal box details. 5

Local Control Panel Instruction Manual Table 3. Wiring Configurations with DVC600 SIS Digital Valve Controller Ex e mb [ib] IIC Ex ic IIC Ex ia IIB LOOP DVC600 SIS then then DVC600 SIS 4 VDC DVC600 SIS then LOOP DVC600 SIS then then DVC600 SIS 4 VDC DVC600 SIS then LOOP DVC600 SIS then then DVC600 SIS DVC600 SIS Mode Refer to figure Point-to-Point 5 Multi-Drop 6 Point-to-Point 7 Multi-Drop 8 Point-to-Point 9 Multi-Drop 0 Point-to-Point Multi-Drop Point-to-Point 3 Multi-Drop 4 Point-to-Point 5 Multi-Drop 6 Point-to-Point 7 Multi-Drop 8 Point-to-Point 9 Multi-Drop 0 Note For intrinsically safe applications, the forms an intrinsically safe explosion protection system when used with intrinsically safe associated apparatus (a barrier) or with any other intrinsically safe devices. The following requirements must be met: Uo Ui, Io Ii, Po Pi, Co Ci + Cc, Lo Li + Lc. When installing the cover, tighten the screws evenly in a criss cross pattern such as the one indicated in figure 3, to a torque of.8 N m (5 lbf in), to help ensure the cover is properly installed. Figure 3. Proper Cover Installation 3 4 NOTE: TIGHTEN THE SCREWS IN A CRISS CROSS PATTERN TO HELP ENSURE PROPER COVER INSTALLATION. 6

Instruction Manual Local Control Panel Figure 4. Interior Details of Fisher and FIELDVUE DVC600 SIS POWER SELECTOR SWITCH (FACTORY DEFAULT IS 4VDC) LABEL IDENTIFIES POWER SELECTOR SWITCH SETTING: LEFT = 4VDC RIGHT = LOOP LABEL IDENTIFIES TERMINALS USED WHEN POWER SELECTOR SWITCH IS SET TO 4VDC. NOTE THAT MIDDLE TERMINAL IS NOT USED WITH THIS SETTING TERMINAL CONNECTIONS: USED FOR BOTH 4VDC AND LOOP POWER SWITCH SELECTION. REFER TO WIRING DIAGRAMS IN THE FOLLOWING FIGURES FOR CORRECT WIRING CONNECTIONS LABEL IDENTIFIES TERMINALS USED WHEN POWER SELECTOR SWITCH IS SET TO LOOP TERMINAL CONNECTIONS: USED WHEN 4VDC POWER SWITCH IS SELECTED AUX + AUX - EARTH GROUND TALK - TALK + LOOP - LOOP + SAFETY GROUND DVC600 SIS TERMINAL BOX INTERIOR GE688-Sheet ELECTRICAL ENTRY 3/4 NPT OR M0 INTERIOR 7

Local Control Panel Instruction Manual Figure 5. Ex e mb [ib] IIC or Wiring Diagram Ex e mb [ib] IIC DVC600 SIS Mode LOOP DVC600 SIS then Point-to-Point 8-0 ma THE MINIMUM MUST BE 8 ma. THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. FOR FLAMEPROOF/EXPLOSION-PROOF APPROVED DIGITAL VALVE CONTROLLERS, INSTALL CONDUIT SEALS OR FLAMEPROOF CABLE GLANDS AS REQUIRED TO MAINTAIN THE FLAMEPROOF/EXPLOSION-PROOF INTEGRITY OF THE DEVICE. GE688-Sheet 3 8

Instruction Manual Local Control Panel Figure 6. Ex e mb [ib] IIC or Wiring Diagram Ex e mb [ib] IIC DVC600 SIS Mode LOOP DVC600 SIS then Multi-Drop FLD SYS 4VDC LC340 LINE CONDITIONER THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. FOR FLAMEPROOF/EXPLOSION-PROOF APPROVED DIGITAL VALVE CONTROLLERS, INSTALL CONDUIT SEALS OR FLAMEPROOF CABLE GLANDS AS REQUIRED TO MAINTAIN THE FLAMEPROOF/EXPLOSION-PROOF INTEGRITY OF THE DEVICE. GE688-Sheet 4 9

Local Control Panel Instruction Manual Figure 7. Ex e mb [ib] IIC or Wiring Diagram 3 Ex e mb [ib] IIC DVC600 SIS Mode LOOP then DVC600 SIS Point-to-Point 8-0 ma THE MINIMUM MUST BE 8 ma. THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. FOR FLAMEPROOF/EXPLOSION-PROOF APPROVED DIGITAL VALVE CONTROLLERS, INSTALL CONDUIT SEALS OR FLAMEPROOF CABLE GLANDS AS REQUIRED TO MAINTAIN THE FLAMEPROOF/EXPLOSION-PROOF INTEGRITY OF THE DEVICE GE688-Sheet 5 0

Instruction Manual Local Control Panel Figure 8. Ex e mb [ib] IIC or Wiring Diagram 4 Ex e mb [ib] IIC DVC600 SIS Mode LOOP then DVC600 SIS Multi-Drop FLD SYS 4VDC LC340 LINE CONDITIONER THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. FOR FLAMEPROOF/EXPLOSION-PROOF APPROVED DIGITAL VALVE CONTROLLERS, INSTALL CONDUIT SEALS OR FLAMEPROOF CABLE GLANDS AS REQUIRED TO MAINTAIN THE FLAMEPROOF/EXPLOSION-PROOF INTEGRITY OF THE DEVICE. GE688-Sheet 6

Local Control Panel Instruction Manual Figure 9. Ex e mb [ib] IIC or Wiring Diagram 5 Ex e mb [ib] IIC DVC600 SIS Mode 4VDC DVC600 SIS then Point-to-Point 4-0 ma 4 VDC SOURCE WHEN 4VDC POWER IS AVAILABLE FOR THE, IT IS NOT NECESSARY TO CONNECT THE LOOP + OF THE DIGITAL VALVE CONTROLLER TO THE LOOP + OF THE. DOING SO WILL CAUSE THE TO UNNECESSARILY CONSUME 4 ma AT THE EXPENSE OF THE DIGITAL VALVE CONTROLLER FOR FLAMEPROOF/EXPLOSION-PROOF APPROVED DIGITAL VALVE CONTROLLERS, INSTALL CONDUIT SEALS OR FLAMEPROOF CABLE GLANDS AS REQUIRED TO MAINTAIN THE FLAMEPROOF/EXPLOSION-PROOF INTEGRITY OF THE DEVICE. GE688-Sheet 7

Instruction Manual Local Control Panel Figure 0. Ex e mb [ib] IIC or Wiring Diagram 6 Ex e mb [ib] IIC DVC600 SIS Mode 4VDC DVC600 SIS then Multi-Drop FLD SYS 4VDC LC340 LINE CONDITIONER 4 VDC SOURCE WHEN 4VDC POWER IS AVAILABLE FOR THE, IT IS NOT NECESSARY TO CONNECT THE LOOP + OF THE DIGITAL VALVE CONTROLLER TO THE LOOP + OF THE. DOING SO WILL CAUSE THE TO UNNECESSARILY CONSUME 4 ma AT THE EXPENSE OF THE DIGITAL VALVE CONTROLLER FOR FLAMEPROOF/EXPLOSION-PROOF APPROVED DIGITAL VALVE CONTROLLERS, INSTALL CONDUIT SEALS OR FLAMEPROOF CABLE GLANDS AS REQUIRED TO MAINTAIN THE FLAMEPROOF/EXPLOSION-PROOF INTEGRITY OF THE DEVICE. GE688-Sheet 8 3

Local Control Panel Instruction Manual Figure. Ex ic IIC or Wiring Diagram Ex ic IIC DVC600 SIS Mode LOOP DVC600 SIS then Point-to-Point LOOP Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh INTRINSICALLY SAFE BARRIER 8-0 ma THE MINIMUM MUST BE 8 ma. THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 9 4

Instruction Manual Local Control Panel Figure. Ex ic IIC or Wiring Diagram Ex ic IIC DVC600 SIS Mode LOOP DVC600 SIS then Multi-Drop LOOP Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh INTRINSICALLY SAFE BARRIER FLD SYS 4 VDC LC340 LINE CONDITIONER THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 0 5

Local Control Panel Instruction Manual Figure 3. Ex ic IIC or Wiring Diagram 3 Ex ic IIC DVC600 SIS Mode LOOP then DVC600 SIS Point-to-Point LOOP Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh INTRINSICALLY SAFE BARRIER 8-0 ma THE MINIMUM MUST BE 8 ma. THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 6

Instruction Manual Local Control Panel Figure 4. Ex ic IIC or Wiring Diagram 4 Ex ic IIC DVC600 SIS Mode LOOP then DVC600 SIS Multi-Drop LOOP Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh INTRINSICALLY SAFE BARRIER 4 VDC FLD SYS LC340 LINE CONDITIONER THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 7

Local Control Panel Instruction Manual Figure 5. Ex ic IIC or Wiring Diagram 5 Ex ic IIC DVC600 SIS Mode 4VDC DVC600 SIS then Point-to-Point LOOP Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh AUX + 4 VDC Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh INTRINSICALLY SAFE BARRIER 4-0 ma AUX - INTRINSICALLY SAFE BARRIER 4 VDC SOURCE WHEN 4 VDC POWER IS AVAILABLE FOR THE, IT IS NOT NECESSARY TO CONNECT THE LOOP + OF THE DIGITAL VALVE CONTROLLER TO THE LOOP + OF THE. DOING SO WILL CAUSE THE TO UNNECESSESARILY CONSUME 4 ma AT THE EXPENSE OF THE DIGITAL VALVE CONTROLLER. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 3 8

Instruction Manual Local Control Panel Figure 6. Ex ic IIC or Wiring Diagram 6 Ex ic IIC DVC600 SIS Mode 4VDC DVC600 SIS then Multi-Drop LOOP Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh AUX + 4 VDC Ui = 7 VDC Ii = N/A Pi = N/A Ci =. nf Li = 0 mh INTRINSICALLY SAFE BARRIER FLD SYS LC340 LINE CONDITIONER 4 VDC AUX - INTRINSICALLY SAFE BARRIER 4 VDC SOURCE WHEN 4 VDC POWER IS AVAILABLE FOR THE, IT IS NOT NECESSARY TO CONNECT THE LOOP + OF THE DIGITAL VALVE CONTROLLER TO THE LOOP + OF THE. DOING SO WILL CAUSE THE TO UNNECESSESARILY CONSUME 4 ma AT THE EXPENSE OF THE DIGITAL VALVE CONTROLLER. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 4 9

Local Control Panel Instruction Manual Figure 7. Ex ia IIB or Wiring Diagram Ex ia IIB DVC600 SIS Mode LOOP DVC600 SIS then Point-to-Point AUX Ui = 30 VDC Ii = 45 ma Pi =.4 W Ci = 0 F Li = 0 mh LOOP Ui = 30 VDC Ii = 6 ma Pi =.4 W Ci = 0. F Li = 6.0 H INTRINSICALLY SAFE BARRIER 8-0 ma THE MINIMUM MUST BE 8 ma. THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 5 0

Instruction Manual Local Control Panel Figure 8. Ex ia IIB or Wiring Diagram Ex ia IIB DVC600 SIS Mode LOOP DVC600 SIS then Multi-Drop AUX Ui = 30 VDC Ii = 45 ma Pi =.4 W Ci = 0 F Li = 0 mh LOOP Ui = 30 VDC Ii = 6 ma Pi =.4 W Ci = 0. F Li = 6.0 H INTRINSICALLY SAFE BARRIER FLD SYS LC340 LINE CONDITIONER 4 VDC THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 6

Local Control Panel Instruction Manual Figure 9. Ex ia IIB or Wiring Diagram 3 Ex ia IIB DVC600 SIS Mode LOOP then DVC600 SIS Point-to-Point LOOP Ui = 30 VDC Ii = 6 ma Pi =.4 W Ci = 0. F Li = 6.0 H AUX Ui = 30 VDC Ii = 45 ma Pi =.4 W Ci = 0 F Li = 0 mh INTRINSICALLY SAFE BARRIER 8-0 ma THE MINIMUM MUST BE 8 ma. THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 7

Instruction Manual Local Control Panel Figure 0. Ex ia IIB or Wiring Diagram 4 Ex ia IIB DVC600 SIS Mode LOOP then DVC600 SIS Multi-Drop LOOP Ui = 30 VDC Ii = 6 ma Pi =.4 W Ci = 0. F Li = 6.0 H AUX Ui = 30 VDC Ii = 45 ma Pi =.4 W Ci = 0 F Li = 0 mh INTRINSICALLY SAFE BARRIER FLD SYS 4 VDC LC340 LINE CONDITIONER THE WHEN POWERED BY THE LOOP CONSUMES APPROXIMATELY 4 ma. REFER TO THE DVC600 SERIES QUICK START GUIDE (D03556X0) FOR SCHEMATICS AND ENTITY PARAMETERS. GE688-Sheet 8 3

Local Control Panel Instruction Manual Pre Setup Testing Before connecting the to the process, conduct the following tests on the connected to the DVC600 SIS. Successful Partial Stroke Test. Press the Valve Test (bottom) pushbutton for more than 3 seconds (but less than 0 seconds).. Observe that the green light starts flashing when the valve starts moving. 3. Observe that the valve moves no more than the configured partial stroke test travel limit. 4. Observe that the valve returns to the normal operating position and the green light comes on solid. Manually Aborted Partial Stroke Test. Press the Valve Test (bottom) pushbutton for more than 3 seconds (but less than 0 seconds).. Observe that the green light starts flashing when the valve starts moving. 3. Before the valve reaches the travel limit of the configured partial stroke test, press the Valve Test pushbutton, or the pushbutton next to the green light. 4. Observe that the valve immediately returns to the normal operating position and the green light comes on solid. Emergency Demand through the. Reduce the current to the DVC600 SIS to 4 ma (for de energize to trip operation). Note For a loop powered installation, a minimum current of 8 ma is required at the trip state / Safety Demand for proper functioning of the pushbuttons and lights.. Observe that the valve moves to its fail safe state. 3. Observe that the red light comes on solid and the yellow light stays off. 4. Press the pushbutton next to the green light and observe that the valve does not move. 5. Increase the current to the DVC600 SIS to 0 ma (for de energize to trip) and observe that the valve remains in its fail safe state. 6. Observe that the red light stays on solid and the yellow light comes on solid (ready to reset). 7. Press the pushbutton next to the green light. 8. Observe that the red light goes off, the valve moves to its normal operating position, and then the green light comes on solid. Emergency Demand through Local Control Panel. Press the pushbutton next to the red light.. Observe that the valve moves to it fail safe position. 3. Observe that the red light comes on solid and the yellow light comes on solid (ready to reset). 4. Press the pushbutton next to the green light. 5. Observe that the red light goes off, the valve moves to its normal operating position, and then the green light comes on solid. 4

Instruction Manual Local Control Panel Setup In order for the to operate properly, it must be connected to a DVC600 SIS with firmware revision 3 or later, or a DVC6000 SIS device with firmware revision 7 or later. Once the physical connections are made, use the following checklist to configure the. Refer to the DVC600 SIS instruction manual (D03557X0) or the DVC6000 SIS instruction manual (D0330X0) if additional setup information is needed. Using a 475 Field Communicator select Configure > Guided Setup > Device Setup. Follow the prompts on the Field Communicator: Enter Supply Pressure and Unit Enter Actuator Make, Model, and Size Enter Partial Stroke test Starting Point, Relay Type and Zero Power Condition [select the instrument connected to local control panel () option] Follow the prompts to complete Device Setup. The following parameters will be automatically set under Travel Alerts: Hi Hi / Lo Lo Enable - Yes Lo Lo Point (%) - Hi Hi Point (%) - 99 Deadband (%) - 0.5 DVC Power Up - Manual Reset Continue to set up the digital valve controller according the normal set up procedure. Remember to place the instrument back in service before disconnecting. Note An alternative method to configure the is through Manual Setup. Using the Field Communicator, select Configure > Manual Setup > Instrument > Terminal Box > Edit Auxiliary Terminal Action > SIS Local Control Panel. When this setting is downloaded to the device, an information screen will pop up advising that some additional parameters will be configured. Select Yes. Principle of Operation The lights indicate the state of the valve as described in table 4. 5

Local Control Panel Instruction Manual Table 4. Fisher Light and Button Operation WHAT THE LIGHTS SHOW... POSSIBLE CONDITIONS... PRESS INDICATED BUTTON TO... Top Middle Bottom Solid The valve is in its normal operating state. - - - Trip Run PST Fast Blink (/ second) Slow Blink ( second) Solid Fast Blink (/ second) The valve is in the process of running a partial stroke test (PST). The valve is not at its normal operating position because the actuator pressure is low or the valve is stuck. Stop PST Trip Stop PST Acknowledge PST Failure Trip Run PST The valve is tripped but is stuck at the normal position. - - - - - - - - - A partial stroke test has failed. Acknowledge PST Failure Trip Run PST The valve is tripped due to loss of actuator pressure (e.g., solenoid valve trip) The valve is tripped due to a command from the logic solver or. Acknowledge PST Failure Trip Run PST - - - - - - - - - The valve is stuck in the tripped state. - - - - - - - - - The valve is at mid-travel after a trip. The valve may be moving or stuck in this position. - - - - - - - - - Solid The valve may be reset to the normal operating state. Reset to Normal State - - - - - - NOTES. If the green, red, and yellow lights are blinking in sequence, then the DVC600 SIS is out of service. In point-to-point mode, the DVC600 SIS will not respond to a trip from the logic solver.. Depending on the emergency shutdown valve configuration, the top button could be labeled Valve Open and the middle button could be labeled Valve Close ; or vice versa. The bottom button will aways be labeled Valve Test. 3. Acknowledgment of a PST failure means that the will return the blinking green light to solid green. The PST alert will still be visible via HART communication with the DVC600 SIS. 4. If the red and green lights are both solid the valve is throttling in mid travel. 5. The information contained in this table applies to firmware 9 and later. Note The primary safety function should be implemented by controlling the current (in point to point mode) or voltage (in multi drop mode) from the logic solver. The red button is not intended to perform the primary safety function for the process. Maintenance WARNING Electrostatic charge hazard. Do not rub or clean the with solvents if a flammable vapor is present. To do so could result in an explosion. The has four major components; the housing, lights, conduit connections, and electronics. If a light is not working it can be replaced with the appropriate color. The conduit connections do not normally need replacement. The electronics module can be replaced as an assembly without having to disconnect the conduit connections or remove the box from its mounting. Instrument Troubleshooting If difficulties are experienced with the control panel, refer to table 5. 6

Instruction Manual Local Control Panel Table 5. Instrument Troubleshooting Symptom Possible Cause Action. Lights are not lit.. is not properly connected to the digital valve controller aux. terminal.. is properly connected to the digital valve controller aux. terminal, but the lights are not lit. 3. The power switch is set correctly, but the lights are not lit. 4. The and the digital valve controller are properly connected, and there is sufficient current but the lights are not lit.. Ensure that the is connected correctly to the digital valve controller aux. terminal, as described in the Installation section of this manual.. Power switch is not set correctly.. Ensure that the power switch is set correctly. If Loop Power is used, ensure that the switch position is set to Loop Power, and NOT 4 VDC, and vice versa. 3. Loop Power option is selected, but there is not enough current. 4. The LED may be damaged. 4. Replace LED. 3. The Loop Power Option requires 8 ma current to operate. Ensure that there is sufficient current. 5. Lights are blinking. 5. Valve is not at it's normal stop. 5. Check for proper calibration. Re run calibration if necessary. 6. Proper calibration but lights are blinking. 6. Hi Hi / Lo Lo alerts settings not correctly set. 6. Ensure that the Hi Hi / Lo Lo Alert settings are 99 and % respectively. For large rotary valve, adjust settings to 98 and % and observe. Parts Ordering When corresponding with your Emerson sales office or Local Business Partner about this equipment, mention the serial number found on the nameplate of the unit. WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher instrument. Use of components not supplied by Emerson Automation Solutions may void your warranty and hazardous area approval, might adversely affect the performance of the instrument, and could cause personal injury and property damage. Parts Kits Parts List Description Part Number LED Assemblies Kit (see figure ) Includes LED's (qty. 3); Yellow, Red, and Green (keys *, *, and 3*) and fasteners (qty. 6) (key 8) GE575X0 Note Contact your Emerson sales office or Local Business Partner for Part Ordering information. Enclosure Labels Kit Includes labels (qty. 6); OPEN, CLOSED, VALVE OPEN, VALVE CLOSE, READY TO RESET, and VALVE TEST Switch Cover Kit Includes switch actuator shroud cover (qty. 3) and Enclosure Labels (qty. 6); OPEN, CLOSED, VALVE OPEN, VALVE CLOSE, READY TO RESET, and VALVE TEST GE5750X0 GE3730X0 Common Parts (see figure ) Key Description 3 3/4 NPT Conduit ( req'd) M0 Conduit ( req'd) 5 Machine Screw (4 req'd) 9* Electronics Module *Recommended spare parts 7

Local Control Panel Instruction Manual Figure. Fisher Assembly SEE FIGURE GE3743 C Figure. Key 9, Electronics Module GE3743 C Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher, FIELDVUE, and Bettis are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. HART is a registered trademark of FieldComm Group. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 5058 USA Sorocaba, 8087 Brazil Cernay, 68700 France Dubai, United Arab Emirates Singapore 846 Singapore www.fisher.com 8 007, 07 Fisher Controls International LLC. All rights reserved.