EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

Similar documents
ECE 4510/5530 Microcontroller Applications Week 6 Lab 5

Concept of Serial Communication

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC)

ANALOG AND DIGITAL PHYSICAL INTERFACES

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

Lecture #3 RS232 & 485 protocols

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

Chapter 12: Digital Modulation and Modems

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

USER'S MANUAL. Model : K

Fanuc Serial (RS232) Communications Information

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

PERIPHERAL INTERFACING Rev. 1.0

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Interface converter G kbit/sec

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Chapter 9: Serial Communication Interface SCI. The HCS12 Microcontroller. Han-Way Huang. September 2009

Atrie WireSpan 600/610 MODEM User's Manual

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

9600 bps, Dual Modem 170 Card Private Wire Only

1 What s in the shipping package?

M7 Over-The-Air Protocol. Overview. Technical Brief AN187 Rev A1

MGE TM Galaxy TM , 60 Hz kva

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

Local Asynchronous Communication. By S.Senthilmurugan Asst.Professor/ICE SRM University. Chennai.

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

+3.3V-Powered, EIA/TIA-562 Dual Transceiver with Receivers Active in Shutdown

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

Cable and Port Specifications

Universal RS232/CMOS to RS422/RS485 Converter

King Fahd University of Petroleum & Minerals Computer Engineering Dept

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

+3.3V, Multiprotocol, 3 Tx/3 Rx, Software- Selectable Clock/Data Transceiver

Intermittent Vibration 0.075

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

+3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers

CL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1

Integrity Instruments

+5V Multiprotocol, Software-Selectable Cable Terminator

1.0 Introduction. Related Products and Documentation

This manual may be copied in any form including electronic. It may not be modified in any way without the express permission of CTC Union

ROM/UDF CPU I/O I/O I/O RAM

This FAQ covers Single Direction use of current loop with transmitting devices.

Chapter 5 Diagnostics

Atrie 33.6K MODEM User's Manual

Miniature Synchronous Multipoint Modems

This FAQ covers the common questions from technicians installing these converters.

CHAPTER 5 TRANSMISSION OF DIGITAL DATA INTERFACES & MODEMS

M9606. FSK Modem. 5C Communications Inc.

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

MDR24x Wireless 2.4GHz Modem

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)

PART 4 DIGITAL METHODS. Chapter 13 Digital Fundamentals. Parallel Data Transfer. Fig Parallel data handshaking

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

ITL Basics of Encoding and Wiring

Myriad MD9612FP Flash Poll Rack-Mount Modem User s Guide MD9612FP USER S GUIDE XXX Page i REV. A

ZCS485 User s Manual. Version ZYPEX, Inc.

SC16C650B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 32-byte FIFOs and infrared (IrDA) encoder/decoder

SP522/SP524. Low-Cost Programmable Multi-Protocol Transceivers

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

Unbounded Transmission Media

C Mono Camera Module with UART Interface. User Manual

TS4000 Radio Modem. User s Manual

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

Revision WI.232FHSS-25-FCC-R and RK-WI.232FHSS-25-FCC-R USER S MANUAL

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

CS601 Data Communication Solved Objective For Midterm Exam Preparation

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Modem E1. Modem-converter E1-L. Features. Contents

2W UHF MHz Radio Transceiver

SC16C Description. 2. Features. Dual UART with 32 bytes of transmit and receive FIFOs

This Special Provision covers the requirements for the installation and testing of fibre optic modems (FOM).

Voice-Frequency Telegraph Modem HY101-SWT

User Guide. Measurement Systems International Quality Industrial Weighing and Force Measurement Equipment

SC16C750B. 1. General description. 2. Features. 5 V, 3.3 V and 2.5 V UART with 64-byte FIFOs

OTi APPROVED SHEET. OTi 6858 Data Sheet USB To RS232 Bridge Controller. OTi-6858 Data Sheet

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

Accutech BR20. DIN rail mounted base radio

CS601-Data Communication Latest Solved Mcqs from Midterm Papers

SC16C550 Rev June 2003 Product data General description Features

Serial Communications RS232, RS485, RS422

ESTEEM USERS MANUAL for MODELS 192C/CHP/F/M/MHP

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

EECE494: Computer Bus and SoC Interfacing. Serial Communication: RS-232. Dr. Charles Kim Electrical and Computer Engineering Howard University

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

Online Signature Verification by Using FPGA

Intelligent +3.0V to +5.5V RS-232 Transceiver

EXPERIMENT NO:-1. OBJECTIVE: To study Basics of serial communication ports and protocols.

CL024 USER S GUIDE VERSION

MODEL 800. GDI Communications, LLC. Dual 1200 BAUD Modem. Verdi, Nevada. rzidnanga-arnnt= Pnnc1 rsf 17

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

Transcription:

EIA EIA-232 Information This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment. The DTE is typically either a dumb terminal or the serial port on a computer/workstation. The DCE is typically a modem, CSU/DSU, or other piece of data communications equipment. Where it gets confusing is when you start to talk about signal definitions and direction. For example, it's easy for someone to understand that when you transmit data, you send it out. However, when you talk in terms of the DCE, it becomes an input. This is because the specification was written from the perspective of the DTE end of the link. Another example is that the Receive Data signal is an input to DTE, but an output from DCE. See Table 1 below. Table: 1 DTE Signal Direction Signal DCE Signal Direction Bi-directional Shield Bi-directional Output TxD Input Input RxD Output Output RTS Input Input CTS Output Input DSR Output Bi-directional SG Bi-directional Input DCD Output Input SDCD Output Input SCTS Output Output STxD Input Input TxClk In Output Input SRxD Output Input RxClk Output Output SRTS Input

Output DTR Input Input RI Output Output TxClk Out Input Therefore, a straight through "one to one" cable is all that is necessary between a modem and a standard DTE serial port. However, if you want to connect two DTE ports together, you have to simulate the existence of the pair of DCE devices, typically modems, that would normally be between the two DTE devices. This is where the null-modem device or cable comes in. See our cabling guide for more info. EIA-232 Signal State Voltage Assignments (see figure 1 below): Voltages of -3v to -25v with respect to signal ground (pin 7) are considered logic '1' (the marking condition), whereas voltages of +3v to +25v are considered logic '0' (the spacing condition). The range of voltages between -3v and +3v is considered a transition region for which a signal state is not assigned. RS-232 signal information Pin Number ITU-T Number Circuit Description 1 N/A N/A Shield 2 103 BA Transmitted Data (TxD) 3 104 BB Received Data (RxD) 4 105/133 CA/CJ Request to send/ready for receiving (RTS) 5 106 CB Clear to send (CTS) 6 107 CC DCE ready (DSR)

7 102 AB Signal common (SG) 8 109 CF Received line signal detector (DCD) 9 N/A N/A (reserved) 10 N/A N/A (reserved) 11 126 N/A (Unassigned) 12 122/112 SCF/CI Secondary received line signal detector/data rate selector (SDCD) 13 121 SCB Secondary clear to send (SCTS) 14 118 SBA 15 114 DB Secondary transmitted data (STxD) Transmitter signal element timing (TxClk In) 16 119 SBB Secondary received data (SRxD) 17 115 DD Receiver signal element timing (RxClk) 18 141 LL Local Loopback (LL) 19 120 SCA Secondary request to send (SRTS) 20 108/1,/2 CD DTE ready (DTR) 21 140/110 RL/CG Remote loopback/signal quality detector (RL) 22 125 CE Ring indicator (RI) 23 111/112 CH/CI Data signal rate selector 24 113 DA Transmit signal element timing (TxClk Out) 25 142 TM Test mode (TM) Signal Definitions Protective Ground or Shield: This circuit establishes a common ground reference potential for all other circuits. TxD, or Transmit Data: This is the primary data channel from the DTE device to the DCE device. The DTE device will use this channel to send data to the DCE device. RxD, or Receive Data: This is the primary data channel from the DCE device to the DTE device. The DCE

device will use this channel to send data to the DTE device. RTS, or Request To Send: This signal is typically used to gate flow from the DCE device's primary data channel to the DTE device. In other words, the workstation serial port would drop this signal to halt flow from the modem, and then later raise it to resume flow. CTS, or Clear To Send: This signal typically is used to gate flow from the DTE device's primary data channel to the DCE device. In other words, a modem may drop this signal to halt flow from the workstation, and then later raise it to resume flow. (see the EIA-232 Flow Control Primer below) DSR, or Data Set Ready or DCE ready: Originally used in half duplex mode as a response to DTR, it is generally not used in full duplex mode. Notable exceptions are VMS and Windows NT, where it's a response to the signal DTR in full duplex mode. SG, or Signal common: This circuit establishes a reference potential for all other circuits. DCD, or Data Carrier Detect or Received line signal detector: This signal is used to show that there is a valid connection between two DCE device's primary channel. It is typically used to block opens on a port before connections, and to generate UNIX "hang up" signals upon loss of a connection. SDCD, or Secondary Data Carrier Detect, or Secondary received line signal detector: This signal is used to show that there is a valid connection between two DCE device's secondary channel. It is typically used to block opens on a port before connections, and to generate UNIX "hang up" signals upon loss of a connection. SCTS, or Secondary Clear To Send: This signal typically is used to gate flow from the DTE device's secondary data channel to the DCE device. In other words, a modem may drop this signal to halt flow from the workstation, and then later raise it to resume flow. (see the EIA-232 Flow Control Primer below) STxD, or Secondary transmitted data: This is the secondary data channel from the DTE device to the DCE device. The DTE device will use this channel to send data to the DCE device. TxClk In, or Transmitter signal element timing (DCE source): This is the signal the transmitting DTE will use to clock the TxD circuit when it needs to send data, if it is not providing clock (TxClk Out). SRxD, or Secondary Received Data: This is the secondary data channel from the DCE device to the DTE device. The DCE device will use this channel to send data to the DTE device.

RxClk, or Receiver Signal Element Timing: This is the circuit the DTE will use to clock incoming data on the RxD circuit. LL, or Local Loopback: This circuit is used by the DTE to force the DCE to loop TxD to RxD. The DCE will also turn the TM (test mode) circuit. This circuit is not implemented on any Digi device. SRTS, or Secondary Request To Send: It is an output for DTE devices and an input for DCE devices. This signal is typically used to gate flow from the DCE device's secondary data channel to the DTE device. In other words, the workstation serial port would drop this signal to halt flow from the modem, and then later raise it to resume flow. (see the EIA-232 Flow Control Primer below) DTR, or Data Terminal Ready: This signal is generally used to indicate that the DTE is ready to receive and transmit data (the ready state). RL, or Remote Loopback: This signal is no longer used in most new designs. This circuit is not implemented on any Digi device. RI, or Ring Indicator: This signal indicates that a ring is being received on a communications channel. The On condition should coincide with the received ring. Data Signal Rate Selector: This signal is used to select the data rate of dual rate DCEs. This circuit is not implemented on any Digi device. TM, or Test Mode: This is a response by the DCE when it's put in Local Loopback or Remote Loopback mode. This circuit is not implemented on any Digi device. EIA-232 Flow Control Primer Hardware flow control uses pins RTS and CTS to gate flow back and forth between two connected serial devices. The DTE device uses RTS to start and stop flow from the DCE device, and the DCE device uses CTS to gate flow from the DTE device. This method is popular for higher speed connections where flow control reaction time is more critical. It's also popular where the data stream is such that embedded flow control characters can not be tolerated by the protocol running on the link. The cost is that you have to run two more wires in the cable. Software flow control uses special START (XON) and STOP (XOFF) characters embedded in the data stream to gate flow. In other words, the receiving device would send a STOP character (typically a control-s) to the sending device to halt flow. It would then later send a START character (typically a control-q) to resume flow.

This method of flow control is more popular for slower links whose protocol can support embedded flow control characters. It's popular because it only requires that you run 3 wires for the link to function. Receive (RxD), Transmit (TxD), and Ground (GND). Further Reading on EIA-232 * Most of the above information was obtained from Mr. Black's book. Black, Uyless D.: Physical Layer Interfaces & Protocols, IEEE Computer Society Press, Los Alamitos, CA, 1996. ISBN 0818656972 http://www.bestbookbuys.com/cgibin/bbb.cgi?searchparam=0818656972&searchtype=isbn&search.x=21&search.y=16 Campbell, Joe: The RS-232 Solution, 2nd ed., Sybex, 1982. Putnam, Byron W.: RS-232 Simplified, Prentice Hall, 1987. Seyer, Martin D.: RS-232 Made Easy, 2nd ed., Prentice Hall, 1991. Copyright 1996-2002 Digi International. All rights reserved.