CERTIFICATE. Issued Date: Oct. 03, 2006 Report No.: 069L003-IT-CE-P11V04

Similar documents
CERTIFICATE. Issued Date: July 27, 2007 Report No.: 076L030-ITCEP07V03

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

Test Report. Product Name : IPC Model No.

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

Test Report. Product Name : MEGA BOOK : MS-1034, MS-1034B, MS-10341, MS-10341B, MS-10342, MS-10342B. Model No. Applicant : MICRO-STAR INTL Co., LTD.

CERTIFICATE. Issued Date: Oct. 18, 2010 Report No.: 10A097R-ITCEP07V03

CERTIFICATE. Issued Date: Feb. 20, 2009 Report No. : R-ITCEP07V06

CERTIFICATE. Issued Date: May 21, 2008 Report No.: R-ITUSP02V01

CERTIFICATE. Issued Date: Jul. 22, 2009 Report No. : R-ITUSP02V02

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: EN : 2000 IEC Edition 1.

CERTIFICATE. Issued Date: Aug. 22, 2008 Report No.: R-ITCEP07V03 This is to certify that the following designated product

Test Report. : 09A255R-ITCEP28V01 Report Version : V1.0

CERTIFICATE. Issued Date: Aug. 20, 2009 Report No.: R-ITUSP02V01

CERTIFICATE. Issued Date: June 23, 2008 Report No.: R-ITUSP02V01

Test Report. Applicant : Moxa Networking Co., Ltd. Address : Fl.8, No.6, Alley 6,Lane 235, Pao-Chiao Rd. Shing Tien City, Taiwan, R.O.C.

Test Report. Product Name : MEGA BOOK. : MS-1057, MS-1057B, S262, S262B, SIM2060, GNB-h2 series. Model No. Applicant : MICRO-STAR INTL Co., LTD.

Test Report. Product Name : MEGA BOOK : MS-1058,MS-1058B,S271,S271B,S271R. Model No. Applicant : MICRO-STAR INT L Co., LTD.

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: EN : 2000 IEC Edition 1.

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: EN : A2: 2005 IEC Edition 1.

CERTIFICATE. Product : IPC Trade name : VISION BOX Model Number : VB-115C/VB-115H/VB-115C-XXX/VB-115H-XXX Company Name : ICPDAS CO.

CERTIFICATE. Issued Date: Apr. 18, 2007 Report No.: 063L031-IT-CE-P11V04-3

CERTIFICATE. Issued Date: Mar. 31, 2009 Report No. : R-ITCEP07V06

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: 2003

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

C-Tick Test Report. : R-ITAUP09V02 Report Version : V1.0

CERTIFICATE EN 55022: 2006 EN 55024: 1998+A1: 2001+A2: EN :2006 IEC Edition 1.2:

CERTIFICATE EN 55022: 2006 EN 55024: 1998+A1: 2001+A2: EN :2006 IEC Edition 1.2: (Level 3)

CERTIFICATE. Issued Date: Oct. 31, 2011 Report No.: R-ITUSP01V01

CERTIFICATE EN 55022: 2006+A1: 2007 EN 55024: 1998+A1: 2001+A2: 2003

Test Report : MS : 103S085E-IT-CE-P01V01 Report Version : V1.0 This report is copy QTK NO: R, only to add one model name

CERTIFICATE. Issued Date: April 16, 2010 Report No. : R-ITCEP07V06

CERTIFICATE. Issued Date: Feb. 06, 2009 Report No. : R-ITCEP07V06

CERTIFICATE. Issued Date: Dec. 02, 2009 Report No. : 09B405R-ITCEP07V06

CERTIFICATE. Issued Date: Nov. 04, 2010 Report No.: 10A036R-ITCEP07V03

Test Report. Product Name : WIRELESS ACCESS POINT

CERTIFICATE. Issued Date: Nov. 09, 2010 Report No.: 10B202R-ITCEP07V04

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

CERTIFICATE. Issued Date: May. 21, 2012 Report No.: R-ITUSP01V01

CERTIFICATE. Issued Date: July 13, 2012 Report No. : R-ITCEP07V06

CERTIFICATE. Issued Date: May. 26, 2009 Report No. : R-ITCEP07V06

EMC. Test Report. Product Name : Rugged BOX PC. : I570EAC-XXX Serial. Model No. Applicant : WinMate Communication INC.

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

CERTIFICATE. Issued Date: Mar. 25, 2009 Report No. : R-ITCEP07V06

Test Report. Product Name : MEGABOOK Model No. : MS-1010, M620

CERTIFICATE. Issued Date: Jul. 03, 2009 Report No. : R-ITCEP07V06

CERTIFICATE. Issued Date: Mar. 04, 2010 Report No.: R-ITCEP07V06

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: EN : 2000 IEC Edition 1.

Report No: 073L039-RFCEP17V01. Test Report. Applicant MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

FCC/IC Test Report. : 2AOIMOMATA1 Equipment authorization required : SDoC IC ID

CERTIFICATE. Issued Date: Jul. 07, 2011 Report No.: R-ITCEP07V06

Test Report. Product Name : Wireless N Day/Night Home Network Camera Model No. : DCS-932, DCS-932L, DCS-930_A2, DCS-930L_A2 FCC ID.

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS Date of Receipt : Apr. 22, Date of Test : May 09, Report No.

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

CERTIFICATE. Issued Date: Sep. 21, 2007 Report No.: R-ITCEP07V04. : HMLCD19L, HMLCD19xxxxx (X=0~9, A~Z) : Honeywell Video Systems

CERTIFICATE. Issued Date: Oct. 05, 2010 Report No.: R-ITCEP02V02

CERTIFICATE OF COMPLIANCE Page 1 of 1

CERTIFICATE. Issued Date: Feb. 17, 2009 Report No. : R-ITCEP07V06

Test Report : MS-1671, MS-1672

Report No R-RFCEP02V01. Test Report. Model No. MS-163C Transmitter Module. Intel / 4965AGN. Date of Receipt July 03, 2007

Report No. 062L020-RF-CE-P02V01-2. Test Report. Model No. MS-1613 Transmitter Module. Intel / WM3945ABG. Date of Receipt Dec.

Report No R-RFCEP02V01. Test Report. Model No. MS-6638, AE 1900 Transmitter Module. MSI / MS-6890

CERTIFICATE. Trade name : MSI Model Number : MS-16371, MS16372 Company Name : MICRO-STAR INTL Co., LTD.

Report No R-RFCEP02V01. Test Report. Model No. MS-N012, U110, U115 Transmitter Module. MSI / MS-6890

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1223, MS-1331 Transmitter Module. MSI / MS Date of Receipt Apr.

Report No. 062L020-RF-CE-P02V01-1. Test Report. MS-1034, MS-1034B, MS-10341, MS-10341B, MS-10342, MS-10342B Transmitter Module.

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1227, MS-1333 Transmitter Module. MSI / MS Date of Receipt Jul.

EN Test Report

Report No R-RFCEP02V01. Test Report. Model No. MS-163A,GX600,GX600X Transmitter Module. Intel / 4965AGN

CE TEST CERTIFICATION

FCC Test Report. : D-Link : DCS-8100LH : KA2CS8100LHA1

Report No. 074L001-RFCEP02V01. Test Report. Model No. MS-1221, PR200 Transmitter Module. Intel / 4965AGN. Date of Receipt Mar.

Test Report. Model No. MS-1049, MS-1049B, L710, 7100U Series (with MS-6833)

Report No R-RFCEP02V01-B. Test Report. Model No. MS-1227, MS-1333 Transmitter Module. Atheros / AR5BXB63

CERTIFICATE. Issued Date: July. 03, 2008 Report No.: R-ITCEP07V04

Report No.: R-RFCEP14V01. Test Report

Test Report. Applicant ICP DAS CO., LTD. Address No. 111, Kuangfu N. Rd., Hukou Shiang, Hsinchu, Taiwan 303, R.O.C.

Report No R-RFCEP02V01-A. Test Report. Product Name Notebook Model No. MS-1731 Transmitter Module MSI / MS-6894

Test Report. Model No. MS-6421, Media Live Transmitter Module. MSI / MS-6874

Test Report. MS-1031,M640,6400,6400 series. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

Report No R-RFCEP02V01. Test Report. Model No. MS-N033,U123 Transmitter Module. MSI / MS-6894

Report No. 071L112-RFCEP02V01-A. Test Report. Model No. MS-1719 Transmitter Module. Intel / 4965AGN. Date of Receipt Jan. 23, 2007

Test Report. Wireless 11g + Bluetooth Combo MiniPCI Card. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

CE EMC Test Certification

Declaration of Conformity (DoC)

CE TEST CERTIFICATION

CERTIFICATE. Issued Date: July. 17, 2009 Report No. : R-ITCEP07V06

Test Report MS-1651, GX620, GT620. MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Report No R-RFCEP02V01. Test Report. Date of Receipt Apr. 28, Issued Date May. 23, 2008

EN :2000+A2:2005, EN :1995+A1:2001

CERTIFICATE. Issued Date: Dec. 23, 2010 Report No. : 10C049R-ITCEP07V06

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1452, EX460, EX461 Transmitter Module. MSI / MS-6891

Test Report FCC Part15 Subpart C

CERTIFICATE. Issued Date: Apr. 16, 2012 Report No.: R-ITUSP02V01. Model Number : NPort 5150(-T), NPort 5130(-T), NPort 5110(-T),

Report No: R-RFCEP14V02. Test Report. For:Intel

Report No R-RFCEP02V01-A. Test Report MS-1644, PR621, PR621X

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1674, EX620 Transmitter Module. MSI / MS-6890

Report No. 09C136R-RFCEP76V01-B. Test Report. Product Name Notebook Model No. MS-1681, CR620, A6200 Transmitter Module MSI / MS-3870

FCC Part15 Subpart C Test Report

Test Report. Applicant MICRO-STAR INT L CO., LTD Address No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan. Date of Receipt Dec.

Transcription:

CERTIFICATE Issued Date: Oct. 03, 2006 Report No.: 069L003-IT-CE-P11V04 This is to certify that the following designated product Product : Barebone Trade name : MSI Model Number : MS-6429, Saturn 865, MS-6434, Saturn 800, MS-6437, Saturn 890 Company Name : MICRO-STAR INTL Co., LTD. This product, which has been issued the test report listed as above in QuieTek Laboratory, is based on a single evaluation of one sample and confirmed to comply with the requirements of the following EMC standard. EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: 2003 EN 61000-3-2: 2000 IEC 61000-4-2 Edition 1.2: 2001-04 EN 61000-3-3: 1995 + A1: 2001 IEC 61000-4-3: 2002+A1: 2002 IEC 61000-4-4: 2004 IEC 61000-4-5 Edition 1.1: 2001-04 IEC 61000-4-6 Edition 2.1: 2004-11 IEC 61000-4-8 Edition 1.1: 2001-03 IEC 61000-4-11 Second Edition: 2004-03 TEST LABORATORY George Chen / President No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:service@quietek.com http://www.quietek.com

Test Report Product Name : Barebone Model No. : MS-6429, Saturn 865, MS-6434, Saturn 800, MS-6437, Saturn 890 Applicant : MICRO-STAR INT L Co., LTD. Address : No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. Date of Receipt : 2006/08/28 Issued Date : 2006/10/02 Report No. : 069L003-IT-CE-P11V04 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by CNLA, NVLAP or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.

Declaration of Conformity The following product is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive (89/336/EEC). The listed standards as below were applied: The following Equipment: Product : Barebone Model Number : MS-6429, Saturn 865, MS-6434, Saturn 800, MS-6437, Saturn 890 Trade Name : MSI This product is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive (89/336/EEC). For the evaluation regarding EMC, the following standards were applied: RFI Emission: EN 55022:1998+A1:2000+A2:2003 Class B : Product family standard EN 61000-3-2:2000 Class D : Limits for harmonic current emission EN 61000-3-3:1995+A1:2001 : Limitation of voltage fluctuation and flicker in low-voltage supply system Immunity: EN 55024:1998+A1:2001+A2:2003 : Product family standard The following importer/manufacturer is responsible for this declaration: Company Name : Company Address : Telephone : Facsimile : Person is responsible for marking this declaration: Name (Full Name) Position/ Title Date Legal Signature

QTK No.: 069L003-IT-CE-P11V04 Statement of Conformity This certifies that the following designated product: Product : Barebone Model Number : MS-6429, Saturn 865, MS-6434, Saturn 800, MS-6437, Saturn 890 Trade Name : MSI Company Name : MICRO-STAR INTL Co., LTD. This product is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive (89/336/EEC). For the evaluation regarding EMC, the following standards were applied: RFI Emission: EN 55022:1998+A1:2000+A2:2003 Class B : Product family standard EN 61000-3-2:2000 Class D : Limits for harmonic current emission EN 61000-3-3:1995+A1:2001 : Limitation of voltage fluctuation and flicker in low-voltage supply system Immunity: EN 55024:1998+A1:2001+A2:2003 : Product family standard TEST LABORATORY 0914 George Chen / President The verification is based on a single evaluation of one sample of above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab. Logo. QuieTek Corporation / No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. Tel: 886-2-8601-3788, Fax: 886-2-8601-3789, E-mail: service@quietek.com

Test Report Certification Issued Date : 2006/10/03 Report No. : 069L003-IT-CE-P11V04 Product Name : Barebone Applicant : MICRO-STAR INT L Co., LTD. Address : No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C. Manufacturer : MICRO-STAR INT L Co., LTD. Model No. : MS-6429, Saturn 865, MS-6434, Saturn 800, MS-6437, Saturn 890 Rated Voltage : AC 230 V / 50 Hz EUT Voltage : AC 220-240V, 50-60Hz Trade Name : MSI Applicable Standard : EN 55022: 1998+A1: 2000+A2: 2003 Class B EN 55024: 1998+A1: 2001+A2: 2003 EN 61000-3-2:2000EN 61000-3-3:1995+A1:2001 AS/NZS CISPR 22: 2006 Test Result : Complied Performed Location : Linkou EMC laboratory No.5-22,Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kuo Shiang, Taipei, 244 Taiwan, R.O.C. TEL:+866-2-8601-3788 / FAX:+886-2-8601-3789 Documented By : ( Rita Huang ) Reviewed By : ( Kent Yao ) Approved By : ( George Chen ) Page: 2 of 176

Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited by the following accreditation Bodies in compliance with ISO 17025, EN 45001 and Guide 25: Taiwan R.O.C. : BSMI, DGT, CNLA Germany : TUV Rheinland Norway : Nemko, DNV USA : FCC, NVLAP Japan : VCCI The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation s Web Site : http://tw.quietek.com/modules/myalbum/ The address and introduction of QuieTek Corporation s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : service@quietek.com 1313 LinKou Testing Laboratory : No. 5-22, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : service@quietek.com 0914 Page: 3 of 176

TABLE OF CONTENTS Description Page 1. General Information... 7 1.1. EUT Description... 7 1.2. Mode of Operation... 9 1.3. Tested System Details... 10 1.4. Configuration of Tested System... 12 1.5. EUT Exercise Software... 14 2. Technical Test... 15 2.1. Summary of Test Result... 15 2.2. List of Test Equipment... 16 2.3. Measurement Uncertainty... 19 2.4. Test Environment... 21 3. Conducted Emission (Main Terminals)... 23 3.1. Test Specification... 23 3.2. Test Setup... 23 3.3. Limit... 23 3.4. Test Procedure... 24 3.5. Deviation from Test Standard... 24 3.6. Test Result... 25 3.7. Test Photograph... 55 4. Conducted Emissions (Telecommunication Ports)... 60 4.1. Test Specification... 60 4.2. Test Setup... 60 4.3. Limit... 60 4.4. Test Procedure... 61 4.5. Deviation from Test Standard... 61 4.6. Test Result... 62 4.7. Test Photograph... 80 5. Radiated Emission... 83 5.1. Test Specification... 83 5.2. Test Setup... 83 5.3. Limit... 83 5.4. Test Procedure... 84 5.5. Deviation from Test Standard... 84 5.6. Test Result... 85 5.7. Test Photograph... 95 6. Harmonic Current Emission... 100 Page: 4 of 176

6.1. Test Specification... 100 6.2. Test Setup... 100 6.3. Limit... 100 6.4. Test Procedure... 102 6.5. Deviation from Test Standard... 102 6.6. Test Result... 103 6.7. Test Photograph... 109 7. Voltage Fluctuation and Flicker...111 7.1. Test Specification...111 7.2. Test Setup...111 7.3. Limit...111 7.4. Test Procedure... 112 7.5. Deviation from Test Standard... 112 7.6. Test Result... 113 7.7. Test Photograph... 116 8. Electrostatic Discharge... 118 8.1. Test Specification... 118 8.2. Test Setup... 118 8.3. Limit... 118 8.4. Test Procedure... 119 8.5. Deviation from Test Standard... 119 8.6. Test Result... 120 8.7. Test Photograph... 123 9. Radiated Susceptibility... 125 9.1. Test Specification... 125 9.2. Test Setup... 125 9.3. Limit... 125 9.4. Test Procedure... 126 9.5. Deviation from Test Standard... 126 9.6. Test Result... 127 9.7. Test Photograph... 130 10. Electrical Fast Transient/Burst... 132 10.1. Test Specification... 132 10.2. Test Setup... 132 10.3. Limit... 132 10.4. Test Procedure... 133 10.5. Deviation from Test Standard... 133 10.6. Test Result... 134 Page: 5 of 176

10.7. Test Photograph... 137 11. Surge... 140 11.1. Test Specification... 140 11.2. Test Setup... 140 11.3. Limit... 140 11.4. Test Procedure... 141 11.5. Deviation from Test Standard... 141 11.6. Test Result... 142 11.7. Test Photograph... 145 12. Conducted Susceptibility... 147 12.1. Test Specification... 147 12.2. Test Setup... 147 12.3. Limit... 148 12.4. Test Procedure... 148 12.5. Deviation from Test Standard... 148 12.6. Test Result... 149 12.7. Test Photograph... 152 13. Power Frequency Magnetic Field... 155 13.1. Test Specification... 155 13.2. Test Setup... 155 13.3. Limit... 155 13.4. Test Procedure... 155 13.5. Deviation from Test Standard... 155 13.6. Test Result... 156 13.7. Test Photograph... 159 14. Voltage Dips and Interruption... 161 14.1. Test Specification... 161 14.2. Test Setup... 161 14.3. Limit... 161 14.4. Test Procedure... 162 14.5. Deviation from Test Standard... 162 14.6. Test Result... 163 14.7. Test Photograph... 166 15. Attachment... 168 EUT Photograph... 168 Page: 6 of 176

1. General Information 1.1. EUT Description Product Name Barebone Trade Name MSI Model No. MS-6429, Saturn 865, MS-6434, Saturn 800, MS-6437, Saturn 890 Mode 1 Component CPU Mother Board HDD VGA Card LAN Card Sound Card Power Supply DDR-RAM AMD AM2 Sempran(tm), 1.8GHz ADM Processor 3400+ MSI, MS-7253 Seagate, ST320014A On Board On Board On Board FSP, ATX350F-C Micron, PC2-4200U-444-12-C0 Mode 2 & Mode 3 Component CPU Intel, Pentium IV (LGA775), 3.4GHz/200MHz, FSB: 800MHz Intel, Pentium IV (LGA775), 3.3GHz/133MHz, FSB: 533MHz Mother Board MSI, MS-7222 HDD Seagate, ST380021A VGA Card On Board LAN Card On Board Sound Card On Board Power Supply FSP, ATX350F-C DDR-RAM Transcend, 130827-2368 Page: 7 of 176

Mode 4 & Mode 5 Component CPU Mother Board HDD VGA Card LAN Card Sound Card Power Supply DDR-RAM Intel, Pentium IV (LGA775), 3.4GHz/200MHz, FSB: 800MHz Intel, Pentium IV (LGA775), 3.3GHz/133MHz, FSB: 533MHz MSI, MS-7101 Maxtor, 6H500FO On Board On Board On Board FSP, ATX350F-C SAMSUNG, PC3200U-30331-EO Note: 1. The different of the each model is shown as below: Model Number MS-6429, Saturn 865 MS-6434, Saturn 800 MS-64237 Saturn 890 Description Marketing requirement Marketing requirement Marketing requirement Page: 8 of 176

1.2. Mode of Operation QuieTek has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: Pre-Test Mode Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Mode 6:MS-6437,AMD AM2 Sempron 3400+,D-Sub(1280*1024/85Hz) Mode 7:MS-6437,AMD AM2 Sempron 3400+,D-Sub(800*600/60Hz) Mode 8:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(800*600/60Hz) Mode 9:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(800*600/60Hz) Final Test Mode Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Emission Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Immunity Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Page: 9 of 176

1.3. Tested System Details The types for all equipments, plus descriptions of all cables used in the tested system (including inserted cards) are: Mode 1 Product Manufacturer Model No. Serial No. Power Cord 1 Modem ACEEX DM-1414 0102027536 Non-Shielded, 1.8m 2 Monitor SONY CPD-G500 2706563 Non-Shielded, 1.8m 3 Walkman AIWA HS-TA164 N/A N/A 4 Microphone & Earphone 5 Microphone & Earphone N/A MIC-06 N/A N/A ROSA RSM-900 N/A Non-Shielded, 1.5m 6 Keyboard COMPAQ KB-0133 B55940MGAPK00W N/A 7 Mouse COMPAQ M-S69 44H0 N/A 8 Printer EPSON StyLus C63 FAPY094256 Non-Shielded, 1.9m 9 Speaker IBM IBM FRU PN 09N5395 10 Speaker IBM IBM FRU PN 09N5395 11 Speaker IBM IBM FRU PN 09N5395 12 COMBO HDD TeraSys F12-UF A0100215-64b0013 Non-Shielded, 1.8m 13 COMBO HDD TeraSys F12-UF A0100215-64b0011 Non-Shielded, 1.8m 14 COMBO HDD TeraSys F12-UF A0100215-64b0002 Non-Shielded, 1.8m 15 COMBO HDD TeraSys F12-UF A0100215-64b0019 Non-Shielded 1.8m 16 COMBO HDD TeraSys F12-UF A0100215-63m0031 Non-Shielded 1.8m 17 COMBO HDD TeraSys F12-UF A0100215-64b0013 Non-Shielded, 1.8m 18 Notebook PC DELL PPT N/A Non-Shielded, 0.8m N/A N/A N/A N/A N/A N/A Page: 10 of 176

Mode 2 & Mode 3 & Mode 4 & Mode 5 Product Manufacturer Model No. Serial No. Power Cord 1 Modem ACEEX DM-1414 0102027536 Non-Shielded, 1.8m 2 Monitor SONY CPD-G500 2706563 Non-Shielded, 1.8m 3 Walkman AIWA HS-TA164 N/A N/A 4 Microphone & PCHOME N/A N/A N/A Earphone 5 Microphone & PCHOME N/A N/A N/A Earphone 6 Keyboard COMPAQ KB-0133 B55940MGAPK00W N/A 7 Mouse COMPAQ M-S69 44H0 N/A 8 Printer EPSON StyLus C63 FAPY094256 Non-Shielded, 1.9m 9 COMBO HDD TeraSys F12-UF A0100215-63m0031 Non-Shielded 1.8m 10 COMBO HDD TeraSys F12-UF A0100215-64b0013 Non-Shielded, 1.8m 11 COMBO HDD TeraSys F12-UF A0100215-63m0031 Non-Shielded 1.8m 12 COMBO HDD TeraSys F12-UF A0100215-64b0019 Non-Shielded 1.8m 13 COMBO HDD TeraSys F12-UF A0100215-64b0013 Non-Shielded, 1.8m 14 COMBO HDD TeraSys F12-UF A0100215-63m0031 Non-Shielded 1.8m 15 Notebook PC DELL PPT N/A Non-Shielded, 0.8m Page: 11 of 176

1.4. Configuration of Tested System Mode 1 Connection Diagram Signal Cable Type Signal cable Description A RS232 Cable Shielded, 1.5m B D-SUB Cable Shielded, 1.8m, with two ferrite cores bonded C Audio Cable Non-Shielded, 1.6m D Earphone & Microphone Cable Non-Shielded, 1.6m E Earphone & Microphone Cable Non-Shielded, 1.6m F Keyboard Cable Shielded, 1.8m G Mouse Cable Shielded, 1.8m H Printer Cable Shielded, 1.2m I Audio Cable Non-Shielded, 1.6m J Audio Cable Non-Shielded, 1.6m K Audio Cable Non-Shielded, 1.6m L USB Cable Shielded, 1.5m M USB Cable Shielded, 1.5m N USB Cable Shielded, 1.5m O USB Cable Shielded, 1.5m P USB Cable Shielded, 1.5m Q USB Cable Shielded, 1.5m R LAN Cable Non-Shielded, 3.0m Page: 12 of 176

Mode 2 & Mode 3 & Mode 4 & Mode 5 Connection Diagram Signal Cable Type Signal cable Description A RS232 Cable Shielded, 1.5m B D-SUB Cable Shielded, 1.8m, with two ferrite cores bonded C Audio Cable Non-Shielded, 1.6m D Earphone & Microphone Cable Non-Shielded, 1.6m E Earphone & Microphone Cable Non-Shielded, 1.6m F Keyboard Cable Shielded, 1.8m G Mouse Cable Shielded, 1.8m H Printer Cable Shielded, 1.2m I USB Cable Shielded, 1.5m J USB Cable Shielded, 1.5m K USB Cable Shielded, 1.5m L USB Cable Shielded, 1.5m M USB Cable Shielded, 1.5m N USB Cable Shielded, 1.5m O LAN Cable Shielded, 3.0m Page: 13 of 176

1.5. EUT Exercise Software 1 Setup the EUT and simulators as shown on 1.4. 2 Turn on the power of all equipment and EUT. 3 EUT reads data from disk. 4 EUT Computer sends H pattern to monitor and printer, the printer will print H pattern on paper. 5 EUT reads and writes data into and from modem. 6 EUT will read data from floppy disk and then writes the data into floppy disk, same operation for hard disk. 7 Repeat the above procedure 3 to 6 8 EUT Connect another simulation PC through LAN port and carry out Read/Write work each other. Page: 14 of 176

2. Technical Test 2.1. Summary of Test Result No deviations from the test standards Deviations from the test standards as below description: Emission Performed Item Normative References Test Performed Deviation Conducted Emission EN 55022:1998+A1:2000+A2:2003 Class B Yes No AS/NZS CISPR 22: 2006 Impedance Stabilization EN 55022:1998+A1:2000+A2:2003 Class B Yes No Network AS/NZS CISPR 22: 2006 Radiated Emission EN 55022:1998+A1:2000+A2:2003 Class B Yes No AS/NZS CISPR 22: 2006 Power Harmonics EN 61000-3-2:2000 Yes No Voltage Fluctuation and Flicker EN 61000-3-3:1995+A1:2001 Yes No Immunity Performed Item Normative References Test Performed Deviation Electrostatic Discharge IEC 61000-4-2 Edition 1.2: 2001-04 Yes No Radiated susceptibility IEC 61000-4-3:2002+A1:2002 Yes No Electrical fast transient/burst IEC 61000-4-4:2004 Yes No Surge IEC 61000-4-5 Edition 1.1: 2001-04 Yes No Conducted susceptibility IEC 61000-4-6 Edition 2.1: 2004-11 Yes No Power frequency magnetic field IEC 61000-4-8 Edition 1.1: 2001-03 Yes No Voltage dips and interruption IEC 61000-4-11 2nd Edition: 2004-03 Yes No Page: 15 of 176

2.2. List of Test Equipment Conducted Emission / SR1 Instrument Manufacturer Type No. Serial No Cal. Date EMI Test Receiver R&S ESCS 30 836858/022 2006/02/18 LISN R&S ESH3-Z5 836679/020 2006/02/14 LISN R&S ENV4200 833209/007 2006/07/13 Pulse Limiter R&S ESH3-Z2 357.88.10.52 2006/09/04 Impedance Stabilization Network / SR1 Instrument Manufacturer Type No. Serial No Cal. Date Capacitive Voltage Probe Schaffner CVP2200A 18331 2005/11/11 EMI Test Receiver R&S ESCS 30 836858/022 2006/02/18 LISN R&S ENV4200 833209/007 2006/07/13 LISN R&S ESH3-Z5 836679/020 2006/02/14 lmpedance Stabilization Network Schaffner ISN T400 19099 2006/07/15 Pulse Limiter R&S ESH3-Z2 357.88.10.52 2006/09/04 RF Current Probe FCC F-65 10KHz~1GHz 198 2005/11/11 Radiated Emission / Site3 Instrument Manufacturer Type No. Serial No Cal. Date Bilog Antenna Schaffner Chase CBL6112B 2704 2006/08/09 Broadband Horn Antenna Schwarzbeck BBHA9170 208 2006/07/25 EMI Test Receiver R&S ESI 26 838786/004 2006/06/19 EMI Test Receiver R&S ESCS 30 838251/001 2006/05/11 Horn Antenna Schwarzbeck BBHA9120D 305 2006/08/10 Pre-Amplifier MITEQ AMF-4D-18040 0-45-6P 925974 2006/01/03 Pre-Amplifier QTK N/A N/A 2006/01/03 Spectrum Analyzer Advantest R3162 101102468 2005/10/24 Power Harmonics / SR3 Instrument Manufacturer Type No. Serial No Cal. Date AC Power Source(Harmonic) Schaffner NSG 1007 HK54148 2006/6/29 IEC1000-4-X Analyzer(Flicker) Schaffner CCN 1000-1 X7 1887 2006/06/29 Voltage Fluctuation and Flicker / SR3 Instrument Manufacturer Type No. Serial No Cal. Date AC Power Source(Harmonic) Schaffner NSG 1007 HK54148 2006/6/29 IEC1000-4-X Analyzer(Flicker) Schaffner CCN 1000-1 X7 1887 2006/06/29 Electrostatic Discharge / SR6 Instrument Manufacturer Type No. Serial No Cal. Date ESD Simulator System KeyTek MZ-15/EC 0112372 2006/08/02 Horizontal Coupling Plane(HCP) QuieTek HCP AL50 N/A N/A Vertical Coupling Plane(VCP) QuieTek VCP AL50 N/A N/A Page: 16 of 176

Radiated susceptibility / CB5 Instrument Manufacturer Type No. Serial No Cal. Date AF-BOX R&S AF-BOX ACCUST 100007 N/A Audio Analyzer R&S UPL 16 100137 2006/03/16 Bilog Antenna Schaffner Chase CBL6112B 2450 2006/01/03 Broad-Band Antenna Schwarzbeck VULB 9166 1085 2006/08/02 CMU200 UNIV.RADIOCOMM R&S CMU200 104846 2006/03/16 Directional Coupler A&R DC 6180 22735 2006/08/03 Dual Microphone Supply B&K 5935 2426784 2006/08/04 Mouth Simulator B&K 4227 2439692 2006/08/04 Power Amplifier A&R 100W10000M7 A285000010 N/A Power Amplifier A&R 30S1G3 309453 N/A Power Meter R&S NRVD(P.M) 100219 2006/04/21 Pre-Amplifier A&R 150A220 23067 N/A Probe Microphone B&K 4182 2278070 2006/08/04 Signal Generator R&S SMY02(9K-208 0) 825454/028 2005/10/03 Electrical fast transient/burst / SR2 Instrument Manufacturer Type No. Serial No Cal. Date Schaffner NSG 2050 System Mainframe Surge / SR6 Instrument Manufacturer Type No. Serial No Cal. Date Schaffner NSG 2050 System Mainframe EMC immunity system Thermo EMCPRO PLUS 0411225 2005/12/01 Conducted susceptibility / SR6 Instrument Manufacturer Type No. Serial No Cal. Date Schaffner NSG 2070 RF-Generator N/A N/A N/A N/A N/A Power frequency magnetic field / SR3 Instrument Manufacturer Type No. Serial No Cal. Date Induction Coil Interface Schaffner INA 2141 6002 N/A Magnetic Loop Coil Schaffner INA 702 199749-020IN N/A Magnetic/Electric field measuring system Lackmann Phymetric MV3 N/A N/A Triaxial ELF Magnetic Field Meter F.B.BELL 4090 9852 2005/05/30 Voltage dips and interruption / SR6 Instrument Manufacturer Type No. Serial No Cal. Date Schaffner NSG 2050 System Mainframe EMC immunity system Thermo EMCPRO PLUS 0411225 2005/12/01 Page: 17 of 176

Schaffner NSG 2050 System Mainframe Instrument Manufacturer Type No. Serial No Cal. Date Burst 4.8KV/16A Generator with CDN Schaffner PNW2225 200123-098SC 2005/12/28 Damped osc. Wave 100kHz and 1MHz Schaffner PNW2056 200124-058SC 2005/12/28 Double AC Source Variator Schaffner NSG 642A 30910014938 2005/12/28 Hybrid surge pulse 1.2/50uS Schaffner PNW 2050 20532-514LU 2006/01/03 PQT Generator Schaffner PNW2003 200138-007SC 2006/01/02 Pulse COUPLING NETWORK Schaffner CDN131 200124-007SC 2005/12/28 Schaffner NSG 2070 RF-Generator Instrument Manufacturer Type No. Serial No Cal. Date CDN Schaffner CAL U100A 20405 2006/03/27 CDN Schaffner TRA U150 20454 2006/03/27 CDN M016S Schaffner CAL U100A 20410 2006/03/27 CDN M016S Schaffner TRA U150 21167 2006/03/27 CDN T002 Schaffner CAL U100 20491 2006/03/27 CDN T002 Schaffner TRA U150 21169 2006/03/27 CDN T400 Schaffner CAL U100 17735 2006/03/27 CDN T400 Schaffner TRA U150 21166 2006/03/27 Coupling Decoupling Network Schaffner CDN M016S 20822 2006/03/27 Coupling Decoupling Network Schaffner CDN M016S 20823 2006/03/27 Coupling Decoupling Network Schaffner CDN T002 19018 2006/03/27 Coupling Decoupling Network Schaffner CDN T400 21226 2006/03/27 EM-CLAMP Schaffner KEMZ 801 21024 2005/04/21 Page: 18 of 176

2.3. Measurement Uncertainty Conducted Emission The measurement uncertainty is evaluated as ± 2.26 db. Impedance Stabilization Network The measurement uncertainty is evaluated as ± 2.26 db. Radiated Emission The measurement uncertainty is evaluated as ± 3.19 db. Electrostatic Discharge As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in ESD testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant ESD standards. The immunity test signal from the ESD system meet the required specifications in IEC 61000-4-2 through the calibration report with the calibrated uncertainty for the waveform of voltage and timing as being 1.63 % and 2.76%. Radiated susceptibility As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in RS testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant RS standards. The immunity test signal from the RS system meet the required specifications in IEC 61000-4-3 through the calibration for the uniform field strength and monitoring for the test level with the uncertainty evaluation report for the electrical filed strength as being 2.72 db. Electrical fast transient/burst As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in EFT/Burst testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant EFT/Burst standards. The immunity test signal from the EFT/Burst system meet the required specifications in IEC 61000-4-4 through the calibration report with the calibrated uncertainty for the waveform of voltage, frequency and timing as being 1.63 %, 2.8 10-10 and 2.76%. Surge As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in Surge testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant Surge standards. The immunity test signal from the Surge system meet the required specifications in IEC 61000-4-5 through the calibration report with the calibrated uncertainty for the waveform of voltage and timing as being 1.63 % and 2.76%. Conducted susceptibility Page: 19 of 176

As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in CS testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant CS standards. The immunity test signal from the CS system meet the required specifications in IEC 61000-4-6 through the calibration for unmodulated signal and monitoring for the test level with the uncertainty evaluation report for the injected modulated signal level through CDN and EM Clamp/Direct Injection as being 3.72 db and 2.78 db. Power frequency magnetic field As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in PFM testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant PFM standards. The immunity test signal from the PFM system meet the required specifications in IEC 61000-4-8 through the calibration report with the calibrated uncertainty for the Gauss Meter to verify the output level of magnetic field strength as being 2 %. Voltage dips and interruption As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025: 1999[2], the requirements for measurement uncertainty in DIP testing are deemed to have been satisfied, and the testing is reported in accordance with the relevant DIP standards. The immunity test signal from the DIP system meet the required specifications in IEC 61000-4-11 through the calibration report with the calibrated uncertainty for the waveform of voltage and timing as being 1.63 % and 2.76%. Page: 20 of 176

2.4. Test Environment Performed Item Items Required Actual Temperature ( C) 15-35 25 Conducted Emission Humidity (%RH) 25-75 50 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 25 Impedance Stabilization Humidity (%RH) 25-75 50 Network Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 25 Radiated Emission Humidity (%RH) 25-75 50 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 23 Electrostatic Discharge Humidity (%RH) 30-60 46 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 24 Radiated susceptibility Humidity (%RH) 25-75 40 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 24 Electrical fast transient/burst Humidity (%RH) 25-75 40 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 24.5 Surge Humidity (%RH) 10-75 41 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 22 Conducted susceptibility Humidity (%RH) 25-75 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 22 Power frequency Humidity (%RH) 25-75 49 Page: 21 of 176

magnetic field Voltage dips and interruption Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) 15-35 23 Humidity (%RH) 25-75 47 Barometric pressure (mbar) 860-1060 950-1000 Page: 22 of 176

3. Conducted Emission (Main Terminals) 3.1. Test Specification According to EMC Standard : EN 55022 and AS/NZS CISPR 22: 2006 3.2. Test Setup 3.3. Limit Limits Frequency (MHz) QP AV 0.15-0.50 66-56 56 46 0.50-5.0 56 46 5.0-30 60 50 Remarks: In the above table, the tighter limit applies at the band edges. Page: 23 of 176

3.4. Test Procedure The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.) Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed on conducted measurement. Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9kHz. 3.5. Deviation from Test Standard No deviation. Page: 24 of 176

3.6. Test Result Site : SR-1 Time : 2006/09/26-01:10 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 1 Page: 25 of 176

Site : SR-1 Time : 2006/09/26-01:12 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 1 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 36.170 36.372-28.057 64.429 QUASIPEAK 2 0.478 0.216 42.930 43.146-13.483 56.629 QUASIPEAK 3 * 0.548 0.217 43.080 43.297-12.703 56.000 QUASIPEAK 4 1.091 0.244 34.320 34.564-21.436 56.000 QUASIPEAK 5 1.845 0.268 35.750 36.018-19.982 56.000 QUASIPEAK 6 9.906 0.632 33.620 34.252-25.748 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 26 of 176

Site : SR-1 Time : 2006/09/26-01:12 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 1 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 30.640 30.842-23.587 54.429 AVERAGE 2 0.478 0.216 30.220 30.436-16.193 46.629 AVERAGE 3 * 0.548 0.217 32.040 32.257-13.743 46.000 AVERAGE 4 1.091 0.244 21.740 21.984-24.016 46.000 AVERAGE 5 1.845 0.268 24.250 24.518-21.482 46.000 AVERAGE 6 9.906 0.632 24.080 24.712-25.288 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 27 of 176

Site : SR-1 Time : 2006/09/26-01:13 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 1 Page: 28 of 176

Site : SR-1 Time : 2006/09/26-01:15 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 1 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 36.660 36.862-27.567 64.429 QUASIPEAK 2 0.478 0.216 42.710 42.926-13.703 56.629 QUASIPEAK 3 * 0.548 0.217 42.350 42.567-13.433 56.000 QUASIPEAK 4 0.755 0.230 36.350 36.580-19.420 56.000 QUASIPEAK 5 2.462 0.292 35.460 35.752-20.248 56.000 QUASIPEAK 6 6.433 0.425 34.160 34.585-25.415 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 29 of 176

Site : SR-1 Time : 2006/09/26-01:15 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 1 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 32.050 32.252-22.177 54.429 AVERAGE 2 0.478 0.216 29.700 29.916-16.713 46.629 AVERAGE 3 * 0.548 0.217 30.960 31.177-14.823 46.000 AVERAGE 4 0.755 0.230 30.080 30.310-15.690 46.000 AVERAGE 5 2.462 0.292 23.680 23.972-22.028 46.000 AVERAGE 6 6.433 0.425 32.180 32.605-17.395 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 30 of 176

Site : SR-1 Time : 2006/09/26-02:23 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 2 Page: 31 of 176

Site : SR-1 Time : 2006/09/26-02:25 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 2 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.341 0.214 35.170 35.384-25.159 60.543 QUASIPEAK 2 0.478 0.216 42.810 43.026-13.603 56.629 QUASIPEAK 3 * 0.545 0.217 43.950 44.167-11.833 56.000 QUASIPEAK 4 1.564 0.260 36.030 36.290-19.710 56.000 QUASIPEAK 5 2.720 0.306 35.590 35.896-20.104 56.000 QUASIPEAK 6 10.189 0.646 33.790 34.436-25.564 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 32 of 176

Site : SR-1 Time : 2006/09/26-02:25 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 2 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.341 0.214 26.960 27.174-23.369 50.543 AVERAGE 2 0.478 0.216 31.610 31.826-14.803 46.629 AVERAGE 3 * 0.545 0.217 34.840 35.057-10.943 46.000 AVERAGE 4 1.564 0.260 25.590 25.850-20.150 46.000 AVERAGE 5 2.720 0.306 25.360 25.666-20.334 46.000 AVERAGE 6 10.189 0.646 24.730 25.376-24.624 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 33 of 176

Site : SR-1 Time : 2006/09/26-02:26 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 2 Page: 34 of 176

Site : SR-1 Time : 2006/09/26-02:28 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 2 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 35.350 35.552-28.877 64.429 QUASIPEAK 2 0.474 0.216 40.190 40.406-16.337 56.743 QUASIPEAK 3 * 0.545 0.217 43.520 43.737-12.263 56.000 QUASIPEAK 4 1.498 0.260 35.800 36.060-19.940 56.000 QUASIPEAK 5 2.451 0.292 34.650 34.942-21.058 56.000 QUASIPEAK 6 10.338 0.548 31.850 32.398-27.602 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 35 of 176

Site : SR-1 Time : 2006/09/26-02:28 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 2 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 29.780 29.982-24.447 54.429 AVERAGE 2 0.474 0.216 29.330 29.546-17.197 46.743 AVERAGE 3 * 0.545 0.217 34.630 34.847-11.153 46.000 AVERAGE 4 1.498 0.260 24.970 25.230-20.770 46.000 AVERAGE 5 2.451 0.292 24.300 24.592-21.408 46.000 AVERAGE 6 10.338 0.548 23.060 23.608-26.392 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 36 of 176

Site : SR-1 Time : 2006/09/26-02:29 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 3 Page: 37 of 176

Site : SR-1 Time : 2006/09/26-02:31 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 3 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.170 0.202 36.240 36.442-28.987 65.429 QUASIPEAK 2 0.478 0.216 43.120 43.336-13.293 56.629 QUASIPEAK 3 * 0.548 0.217 43.850 44.067-11.933 56.000 QUASIPEAK 4 1.365 0.248 35.420 35.668-20.332 56.000 QUASIPEAK 5 2.595 0.294 36.140 36.434-19.566 56.000 QUASIPEAK 6 10.017 0.633 28.670 29.303-30.697 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 38 of 176

Site : SR-1 Time : 2006/09/26-02:31 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 3 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.170 0.202 32.830 33.032-22.397 55.429 AVERAGE 2 0.478 0.216 31.290 31.506-15.123 46.629 AVERAGE 3 * 0.548 0.217 34.630 34.847-11.153 46.000 AVERAGE 4 1.365 0.248 24.190 24.438-21.562 46.000 AVERAGE 5 2.595 0.294 26.400 26.694-19.306 46.000 AVERAGE 6 10.017 0.633 20.770 21.403-28.597 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 39 of 176

Site : SR-1 Time : 2006/09/26-02:31 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 3 Page: 40 of 176

Site : SR-1 Time : 2006/09/26-02:33 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 3 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 35.910 36.112-28.317 64.429 QUASIPEAK 2 0.478 0.216 42.770 42.986-13.643 56.629 QUASIPEAK 3 * 0.548 0.217 43.320 43.537-12.463 56.000 QUASIPEAK 4 0.963 0.232 35.660 35.892-20.108 56.000 QUASIPEAK 5 2.666 0.305 34.660 34.965-21.035 56.000 QUASIPEAK 6 6.224 0.423 31.770 32.193-27.807 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 41 of 176

Site : SR-1 Time : 2006/09/26-02:33 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 3 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 30.810 31.012-23.417 54.429 AVERAGE 2 0.478 0.216 30.730 30.946-15.683 46.629 AVERAGE 3 * 0.548 0.217 33.730 33.947-12.053 46.000 AVERAGE 4 0.963 0.232 32.370 32.602-13.398 46.000 AVERAGE 5 2.666 0.305 24.380 24.685-21.315 46.000 AVERAGE 6 6.224 0.423 28.120 28.543-21.457 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 42 of 176

Site : SR-1 Time : 2006/09/26-03:28 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 4 Page: 43 of 176

Site : SR-1 Time : 2006/09/26-03:30 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 4 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.166 0.202 39.810 40.012-25.531 65.543 QUASIPEAK 2 0.478 0.216 43.000 43.216-13.413 56.629 QUASIPEAK 3 * 0.545 0.217 43.690 43.907-12.093 56.000 QUASIPEAK 4 1.498 0.260 35.600 35.860-20.140 56.000 QUASIPEAK 5 2.654 0.299 32.900 33.199-22.801 56.000 QUASIPEAK 6 10.140 0.635 27.870 28.505-31.495 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 44 of 176

Site : SR-1 Time : 2006/09/26-03:30 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 4 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.166 0.202 35.470 35.672-19.871 55.543 AVERAGE 2 0.478 0.216 32.340 32.556-14.073 46.629 AVERAGE 3 * 0.545 0.217 34.630 34.847-11.153 46.000 AVERAGE 4 1.498 0.260 25.200 25.460-20.540 46.000 AVERAGE 5 2.654 0.299 23.710 24.009-21.991 46.000 AVERAGE 6 10.140 0.635 20.500 21.135-28.865 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 45 of 176

Site : SR-1 Time : 2006/09/26-03:30 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 4 Page: 46 of 176

Site : SR-1 Time : 2006/09/26-03:32 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 4 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.166 0.202 39.540 39.742-25.801 65.543 QUASIPEAK 2 0.482 0.216 42.300 42.516-13.998 56.514 QUASIPEAK 3 * 0.548 0.217 43.650 43.867-12.133 56.000 QUASIPEAK 4 1.435 0.249 35.390 35.639-20.361 56.000 QUASIPEAK 5 2.462 0.292 36.500 36.792-19.208 56.000 QUASIPEAK 6 6.092 0.415 34.990 35.405-24.595 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 47 of 176

Site : SR-1 Time : 2006/09/26-03:32 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 4 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.166 0.202 34.760 34.962-20.581 55.543 AVERAGE 2 0.482 0.216 31.900 32.116-14.398 46.514 AVERAGE 3 * 0.548 0.217 33.730 33.947-12.053 46.000 AVERAGE 4 1.435 0.249 25.420 25.669-20.331 46.000 AVERAGE 5 2.462 0.292 27.840 28.132-17.868 46.000 AVERAGE 6 6.092 0.415 33.880 34.295-15.705 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 48 of 176

Site : SR-1 Time : 2006/09/26-03:34 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 5 Page: 49 of 176

Site : SR-1 Time : 2006/09/26-03:35 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 5 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.166 0.202 39.120 39.322-26.221 65.543 QUASIPEAK 2 * 0.482 0.216 43.300 43.516-12.998 56.514 QUASIPEAK 3 0.548 0.217 42.350 42.567-13.433 56.000 QUASIPEAK 4 1.779 0.263 35.690 35.953-20.047 56.000 QUASIPEAK 5 2.670 0.304 35.140 35.444-20.556 56.000 QUASIPEAK 6 10.127 0.635 34.080 34.715-25.285 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 50 of 176

Site : SR-1 Time : 2006/09/26-03:35 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(L) - Line1 Power : AC 230V/50Hz Note : Mode 5 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.166 0.202 35.170 35.372-20.171 55.543 AVERAGE 2 0.482 0.216 32.340 32.556-13.958 46.514 AVERAGE 3 * 0.548 0.217 31.960 32.177-13.823 46.000 AVERAGE 4 1.779 0.263 25.420 25.683-20.317 46.000 AVERAGE 5 2.670 0.304 25.040 25.344-20.656 46.000 AVERAGE 6 10.127 0.635 24.890 25.525-24.475 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 51 of 176

Site : SR-1 Time : 2006/09/26-03:36 Limit : CISPR_B_00M_QP Margin : 10 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 5 Page: 52 of 176

Site : SR-1 Time : 2006/09/26-03:38 Limit : CISPR_B_00M_QP Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 5 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 37.100 37.302-27.127 64.429 QUASIPEAK 2 * 0.482 0.216 43.610 43.826-12.688 56.514 QUASIPEAK 3 0.552 0.217 42.630 42.847-13.153 56.000 QUASIPEAK 4 1.712 0.262 36.180 36.442-19.558 56.000 QUASIPEAK 5 2.673 0.305 36.500 36.805-19.195 56.000 QUASIPEAK 6 6.107 0.420 29.130 29.550-30.450 60.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 53 of 176

Site : SR-1 Time : 2006/09/26-03:38 Limit : CISPR_B_00M_AV Margin : 0 EUT : BAREBONE Probe : LISN-020(N) - Line2 Power : AC 230V/50Hz Note : Mode 5 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.205 0.202 32.930 33.132-21.297 54.429 AVERAGE 2 0.482 0.216 32.470 32.686-13.828 46.514 AVERAGE 3 * 0.552 0.217 32.110 32.327-13.673 46.000 AVERAGE 4 1.712 0.262 27.820 28.082-17.918 46.000 AVERAGE 5 2.673 0.305 26.080 26.385-19.615 46.000 AVERAGE 6 6.107 0.420 25.850 26.270-23.730 50.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 54 of 176

3.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Front View of Conducted Test Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Back View of Conducted Test Page: 55 of 176

Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Front View of Conducted Test Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Back View of Conducted Test Page: 56 of 176

Test Mode : Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Front View of Conducted Test Test Mode : Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Back View of Conducted Test Page: 57 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Front View of Conducted Test Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Back View of Conducted Test Page: 58 of 176

Test Mode : Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Front View of Conducted Test Test Mode : Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Back View of Conducted Test Page: 59 of 176

4. Conducted Emissions (Telecommunication Ports) 4.1. Test Specification According to EMC Standard : EN 55022 and AS/NZS CISPR 22: 2006 4.2. Test Setup 4.3. Limit Limits Frequency (MHz) QP AV 0.15-0.50 84 74 74 64 0.50-30 74 64 Remarks: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz~0.50 MHz. Page: 60 of 176

4.4. Test Procedure Telecommunication Port: The mains voltage shall be supplied to the EUT via the LISN when the measurement of telecommunication port is performed. The common mode disturbances at the telecommunication port shall be connected to the ISN, which is 150 ohm impedance. Both alternative cables are tested related to the LCL requested. The measurement range is from 150kHz to 30MHz. The bandwidth of measurement is set to 9kHz. The 60dB LCL ISN is used for cat. 5 cable, 50dB LCL ISN is used for cat. 3 and 80dB LCL is used for alternative one. 4.5. Deviation from Test Standard No deviation. Page: 61 of 176

4.6. Test Result Site : SR-1 Time : 2006/09/26-05:00 Limit : ISN_Voltage_B_10db_00M_QP Margin : 10 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 1: ISN 100Mbps Page: 62 of 176

Site : SR-1 Time : 2006/09/26-05:02 Limit : ISN_Voltage_B_10db_00M_QP Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 1: ISN 100Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.404 9.780 45.810 55.590-21.153 76.743 QUASIPEAK 2 0.791 9.750 47.570 57.320-16.680 74.000 QUASIPEAK 3 * 1.087 9.734 55.130 64.864-9.136 74.000 QUASIPEAK 4 8.228 9.799 46.440 56.239-27.761 84.000 QUASIPEAK 5 18.244 9.863 60.390 70.253-13.747 84.000 QUASIPEAK 6 23.127 9.918 61.160 71.078-12.922 84.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 63 of 176

Site : SR-1 Time : 2006/09/26-05:02 Limit : ISN_Voltage_B_10db_00M_AV Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 1: ISN 100Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.404 9.780 35.510 45.290-21.453 66.743 AVERAGE 2 0.791 9.750 38.200 47.950-16.050 64.000 AVERAGE 3 * 1.087 9.734 52.160 61.894-2.106 64.000 AVERAGE 4 8.228 9.799 44.890 54.689-19.311 74.000 AVERAGE 5 18.244 9.863 58.780 68.643-5.357 74.000 AVERAGE 6 23.127 9.918 59.110 69.028-4.972 74.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 64 of 176

Site : SR-1 Time : 2006/09/26-05:03 Limit : ISN_Voltage_B_10db_00M_QP Margin : 10 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 1: ISN 10Mbps Page: 65 of 176

Site : SR-1 Time : 2006/09/26-05:06 Limit : ISN_Voltage_B_10db_00M_QP Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 1: ISN 10Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.369 9.784 46.540 56.324-21.419 77.743 QUASIPEAK 2 0.724 9.757 52.560 62.317-11.683 74.000 QUASIPEAK 3 1.087 9.734 55.250 64.984-9.016 74.000 QUASIPEAK 4 5.052 9.767 39.160 48.927-25.073 74.000 QUASIPEAK 5 * 9.994 9.813 65.700 75.513-8.487 84.000 QUASIPEAK 6 14.982 9.849 40.700 50.549-33.451 84.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 66 of 176

Site : SR-1 Time : 2006/09/26-05:06 Limit : ISN_Voltage_B_10db_00M_AV Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 1: ISN 10Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.369 9.784 33.670 43.454-24.289 67.743 AVERAGE 2 0.724 9.757 43.920 53.677-10.323 64.000 AVERAGE 3 * 1.087 9.734 52.270 62.004-1.996 64.000 AVERAGE 4 5.052 9.767 17.110 26.877-37.123 64.000 AVERAGE 5 9.994 9.813 46.300 56.113-17.887 74.000 AVERAGE 6 14.982 9.849 17.310 27.159-46.841 74.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 67 of 176

Site : SR-1 Time : 2006/09/26-04:38 Limit : ISN_Voltage_B_10db_00M_QP Margin : 10 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 2: ISN 100Mbps Page: 68 of 176

Site : SR-1 Time : 2006/09/26-04:41 Limit : ISN_Voltage_B_10db_00M_QP Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 2: ISN 100Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.432 9.775 38.890 48.665-27.278 75.943 QUASIPEAK 2 0.775 9.750 44.730 54.480-19.520 74.000 QUASIPEAK 3 1.167 9.735 39.690 49.425-24.575 74.000 QUASIPEAK 4 7.923 9.795 52.160 61.955-22.045 84.000 QUASIPEAK 5 * 16.228 9.856 61.880 71.736-12.264 84.000 QUASIPEAK 6 17.693 9.866 61.480 71.346-12.654 84.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 69 of 176

Site : SR-1 Time : 2006/09/26-04:41 Limit : ISN_Voltage_B_10db_00M_AV Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 2: ISN 100Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.432 9.775 35.400 45.175-20.768 65.943 AVERAGE 2 0.775 9.750 37.220 46.970-17.030 64.000 AVERAGE 3 1.167 9.735 33.220 42.955-21.045 64.000 AVERAGE 4 7.923 9.795 50.630 60.425-13.575 74.000 AVERAGE 5 * 16.228 9.856 60.260 70.116-3.884 74.000 AVERAGE 6 17.693 9.866 60.190 70.056-3.944 74.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 70 of 176

Site : SR-1 Time : 2006/09/26-04:31 Limit : ISN_Voltage_B_10db_00M_QP Margin : 10 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 2: ISN 10Mbps Page: 71 of 176

Site : SR-1 Time : 2006/09/26-04:35 Limit : ISN_Voltage_B_10db_00M_QP Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 2: ISN 10Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.353 9.784 45.980 55.764-22.436 78.200 QUASIPEAK 2 0.611 9.768 52.350 62.118-11.882 74.000 QUASIPEAK 3 1.181 9.735 51.890 61.625-12.375 74.000 QUASIPEAK 4 4.998 9.766 39.110 48.876-25.124 74.000 QUASIPEAK 5 * 9.994 9.813 65.980 75.793-8.207 84.000 QUASIPEAK 6 20.002 9.877 49.190 59.067-24.933 84.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 72 of 176

Site : SR-1 Time : 2006/09/26-04:35 Limit : ISN_Voltage_B_10db_00M_AV Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 2: ISN 10Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.353 9.784 37.370 47.154-21.046 68.200 AVERAGE 2 0.611 9.768 44.180 53.948-10.052 64.000 AVERAGE 3 * 1.181 9.735 45.340 55.075-8.925 64.000 AVERAGE 4 4.998 9.766 17.040 26.806-37.194 64.000 AVERAGE 5 9.994 9.813 45.560 55.373-18.627 74.000 AVERAGE 6 20.002 9.877 31.050 40.927-33.073 74.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 73 of 176

Site : SR-1 Time : 2006/09/26-04:04 Limit : ISN_Voltage_B_10db_00M_QP Margin : 10 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 4: ISN 100Mbps Page: 74 of 176

Site : SR-1 Time : 2006/09/26-04:07 Limit : ISN_Voltage_B_10db_00M_QP Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 4: ISN 100Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.459 9.776 44.000 53.776-21.395 75.171 QUASIPEAK 2 0.779 9.750 40.000 49.750-24.250 74.000 QUASIPEAK 3 1.146 9.735 39.100 48.835-25.165 74.000 QUASIPEAK 4 7.923 9.795 52.600 62.395-21.605 84.000 QUASIPEAK 5 16.166 9.855 60.370 70.225-13.775 84.000 QUASIPEAK 6 * 18.244 9.863 63.050 72.913-11.087 84.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 75 of 176

Site : SR-1 Time : 2006/09/26-04:07 Limit : ISN_Voltage_B_10db_00M_AV Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 4: ISN 100Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.459 9.776 43.760 53.536-11.635 65.171 AVERAGE 2 0.779 9.750 32.530 42.280-21.720 64.000 AVERAGE 3 1.146 9.735 35.720 45.455-18.545 64.000 AVERAGE 4 7.923 9.795 50.440 60.235-13.765 74.000 AVERAGE 5 16.166 9.855 58.070 67.925-6.075 74.000 AVERAGE 6 * 18.244 9.863 60.930 70.793-3.207 74.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 76 of 176

Site : SR-1 Time : 2006/09/26-04:09 Limit : ISN_Voltage_B_10db_00M_QP Margin : 10 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 4: ISN 10Mbps Page: 77 of 176

Site : SR-1 Time : 2006/09/26-04:12 Limit : ISN_Voltage_B_10db_00M_QP Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 4: ISN 10Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 0.459 9.776 44.170 53.946-21.225 75.171 QUASIPEAK 2 0.771 9.750 38.090 47.840-26.160 74.000 QUASIPEAK 3 1.373 9.738 36.460 46.198-27.802 74.000 QUASIPEAK 4 4.982 9.766 40.870 50.636-23.364 74.000 QUASIPEAK 5 7.545 9.791 43.380 53.171-30.829 84.000 QUASIPEAK 6 * 9.992 9.813 62.300 72.113-11.887 84.000 QUASIPEAK Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 78 of 176

Site : SR-1 Time : 2006/09/26-04:12 Limit : ISN_Voltage_B_10db_00M_AV Margin : 0 EUT : BAREBONE Power : AC 230V/50Hz Probe : ISN-T400 - Line1 Note : Mode 4: ISN 10Mbps Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (db) 1 * 0.459 9.776 43.790 53.566-11.605 65.171 AVERAGE 2 0.771 9.750 31.130 40.880-23.120 64.000 AVERAGE 3 1.373 9.738 35.020 44.758-19.242 64.000 AVERAGE 4 4.982 9.766 21.690 31.456-32.544 64.000 AVERAGE 5 7.545 9.791 21.520 31.311-42.689 74.000 AVERAGE 6 9.992 9.813 39.700 49.513-24.487 74.000 AVERAGE Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 79 of 176

4.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Front View of ISN Test Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Back View of ISN Test Page: 80 of 176

Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Front View of ISN Test Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Back View of ISN Test Page: 81 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Front View of ISN Test Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Back View of ISN Test Page: 82 of 176

5. Radiated Emission 5.1. Test Specification According to EMC Standard : EN 55022 and AS/NZS CISPR 22: 2006 5.2. Test Setup 5.3. Limit Frequency (MHz) Limits Distance (m) dbuv/m 30 230 10 30 230 1000 10 37 Remark: 1. The tighter limit shall apply at the edge between two frequency bands. 2. Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the device or system. Page: 83 of 176

5.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT was positioned such that the distance from antenna to the EUT was 10 meters. The antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level. Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated on radiated measurement. Radiated emissions were invested over the frequency range from 30MHz to1ghz using a receiver bandwidth of 120kHz. Radiated was performed at an antenna to EUT distance of 10 meters. 5.5. Deviation from Test Standard No deviation. Page: 84 of 176

5.6. Test Result Site : OATS-3 Time : 2006/09/26-14:13 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - HORIZONTAL Power : AC 230V/50Hz Note : Mode 1 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (dbuv/m) (db) (dbuv/m) 1 * 187.440 11.151 14.110 25.261-4.739 30.000 QUASIPEAK 2 214.205 11.369 11.420 22.789-7.211 30.000 QUASIPEAK 3 225.000 12.147 10.810 22.958-7.042 30.000 QUASIPEAK 4 299.990 16.707 6.430 23.137-13.863 37.000 QUASIPEAK 5 307.207 17.045 5.050 22.095-14.905 37.000 QUASIPEAK 6 480.110 22.174 6.240 28.415-8.585 37.000 QUASIPEAK 7 600.150 24.440 6.300 30.740-6.260 37.000 QUASIPEAK 8 933.920 28.285 3.330 31.615-5.385 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 85 of 176

Site : OATS-3 Time : 2006/09/26-14:03 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - VERTICAL Power : AC 230V/50Hz Note : Mode 1 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (dbuv/m) (db) (dbuv/m) 1 120.000 13.802 10.560 24.362-5.638 30.000 QUASIPEAK 2 187.431 11.151 12.720 23.871-6.129 30.000 QUASIPEAK 3 214.205 11.369 8.310 19.679-10.321 30.000 QUASIPEAK 4 276.490 15.922 6.110 22.032-14.968 37.000 QUASIPEAK 5 331.790 17.927 2.730 20.657-16.343 37.000 QUASIPEAK 6 * 589.843 24.204 7.990 32.194-4.806 37.000 QUASIPEAK 7 638.995 24.848 5.580 30.428-6.572 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 86 of 176

Site : OATS-3 Time : 2006/09/01-16:33 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - HORIZONTAL Power : AC 230V/50Hz Note : Mode 2 Frequency (MHz) Correct Factor Reading Level Measure Level Margin (db) Limit (dbuv/m) Detector Type (db) (dbuv/m) 1 125.000 14.027 6.270 20.297-9.703 30.000 QUASIPEAK 2 200.030 11.613 12.960 24.573-5.427 30.000 QUASIPEAK 3 300.020 16.709 4.250 20.958-16.042 37.000 QUASIPEAK 4 375.000 19.555 3.960 23.514-13.486 37.000 QUASIPEAK 5 419.747 21.215 2.180 23.395-13.605 37.000 QUASIPEAK 6 * 750.030 26.405 5.400 31.805-5.195 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 87 of 176

Site : OATS-3 Time : 2006/09/01-16:22 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - VERTICAL Power : AC 230V/50Hz Note : Mode 2 Frequency (MHz) Correct Factor Reading Level Measure Level Margin (db) Limit (dbuv/m) Detector Type (db) (dbuv/m) 1 125.000 14.027 5.830 19.857-10.143 30.000 QUASIPEAK 2 * 200.020 11.613 12.590 24.203-5.797 30.000 QUASIPEAK 3 300.050 16.710 9.910 26.620-10.380 37.000 QUASIPEAK 4 325.000 17.728 4.090 21.819-15.181 37.000 QUASIPEAK 5 500.000 22.412 2.100 24.512-12.488 37.000 QUASIPEAK 6 651.600 24.778 3.240 28.018-8.982 37.000 QUASIPEAK 7 800.135 26.898 0.500 27.398-9.602 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 88 of 176

Site : OATS-3 Time : 2006/09/25-14:58 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - HORIZONTAL Power : AC 230V/50Hz Note : Mode 3 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (dbuv/m) (db) (dbuv/m) 1 125.000 14.027 11.050 25.077-4.923 30.000 QUASIPEAK 2 216.000 11.388 9.410 20.797-9.203 30.000 QUASIPEAK 3 240.041 14.129 9.010 23.139-13.861 37.000 QUASIPEAK 4 438.199 21.128 2.060 23.188-13.812 37.000 QUASIPEAK 5 532.289 23.367 8.070 31.437-5.563 37.000 QUASIPEAK 6 625.010 24.704 4.620 29.324-7.676 37.000 QUASIPEAK 7 * 750.000 26.405 7.200 33.605-3.395 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 89 of 176

Site : OATS-3 Time : 2006/09/25-14:26 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - VERTICAL Power : AC 230V/50Hz Note : Mode 3 Frequency Correct Factor Reading Level Measure Level Margin Limit Detector Type (MHz) (db) (dbuv/m) (db) (dbuv/m) 1 * 125.000 14.027 11.200 25.227-4.773 30.000 QUASIPEAK 2 135.195 13.688 11.310 24.999-5.001 30.000 QUASIPEAK 3 160.000 12.301 12.200 24.501-5.499 30.000 QUASIPEAK 4 175.000 11.478 6.310 17.788-12.212 30.000 QUASIPEAK 5 216.000 11.388 11.990 23.377-6.623 30.000 QUASIPEAK 6 300.069 16.710 4.850 21.561-15.439 37.000 QUASIPEAK 7 480.000 22.172 3.900 26.072-10.928 37.000 QUASIPEAK 8 750.000 26.405 5.200 31.605-5.395 37.000 QUASIPEAK 9 1000.000 28.918 2.500 31.418-5.582 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 90 of 176

Site : OATS-3 Time : 2006/09/05-10:04 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - HORIZONTAL Power : AC 230V/50Hz Note : Mode 4 Frequency (MHz) Correct Factor Reading Level Measure Level Margin (db) Limit (dbuv/m) Detector Type (db) (dbuv/m) 1 120.000 13.802 4.490 18.292-11.708 30.000 QUASIPEAK 2 266.000 15.931 5.410 21.341-15.659 37.000 QUASIPEAK 3 324.000 17.693 2.140 19.833-17.167 37.000 QUASIPEAK 4 * 480.000 22.172 10.970 33.142-3.858 37.000 QUASIPEAK 5 500.000 22.412 1.980 24.392-12.608 37.000 QUASIPEAK 6 720.000 25.920 4.100 30.020-6.980 37.000 QUASIPEAK 7 972.000 28.847 2.210 31.057-5.943 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 91 of 176

Site : OATS-3 Time : 2006/09/05-10:03 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - VERTICAL Power : AC 230V/50Hz Note : Mode 4 Frequency (MHz) Correct Factor Reading Level Measure Level Margin (db) Limit (dbuv/m) Detector Type (db) (dbuv/m) 1 125.000 14.027 7.310 21.337-8.663 30.000 QUASIPEAK 2 200.000 11.613 10.970 22.583-7.417 30.000 QUASIPEAK 3 * 216.000 11.388 13.980 25.367-4.633 30.000 QUASIPEAK 4 250.000 15.286 15.390 30.676-6.324 37.000 QUASIPEAK 5 500.000 22.412 4.960 27.372-9.628 37.000 QUASIPEAK 6 720.000 25.920 5.420 31.340-5.660 37.000 QUASIPEAK 7 1000.000 28.918 1.090 30.008-6.992 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 92 of 176

Site : OATS-3 Time : 2006/09/25-17:20 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - HORIZONTAL Power : AC 230V/50Hz Note : Mode 5 Frequency (MHz) Correct Factor Reading Level Measure Level Margin (db) Limit (dbuv/m) Detector Type (db) (dbuv/m) 1 120.033 14.866 8.000 22.866-7.134 30.000 QUASIPEAK 2 186.476 12.133 14.230 26.363-3.637 30.000 QUASIPEAK 3 213.113 13.205 10.730 23.934-6.066 30.000 QUASIPEAK 4 240.000 15.210 17.900 33.110-3.890 37.000 QUASIPEAK 5 * 359.994 18.796 15.100 33.896-3.104 37.000 QUASIPEAK 6 479.994 21.507 12.340 33.847-3.153 37.000 QUASIPEAK 7 720.000 24.803 8.600 33.403-3.597 37.000 QUASIPEAK 8 985.667 28.802 5.040 33.842-3.158 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 93 of 176

Site : OATS-3 Time : 2006/09/25-16:55 Limit : CISPR_B_10M_QP Margin : 6 EUT : BAREBONE Probe : CBL6112B-(2704) - VERTICAL Power : AC 230V/50Hz Note : Mode 5 Frequency (MHz) Correct Factor Reading Level Measure Level Margin (db) Limit (dbuv/m) Detector Type (db) (dbuv/m) 1 79.920 10.529 13.180 23.708-6.292 30.000 QUASIPEAK 2 * 120.030 14.866 12.100 26.966-3.034 30.000 QUASIPEAK 3 186.480 12.133 14.709 26.842-3.158 30.000 QUASIPEAK 4 213.117 13.205 11.230 24.435-5.565 30.000 QUASIPEAK 5 240.000 15.210 17.400 32.610-4.390 37.000 QUASIPEAK 6 479.992 21.507 11.700 33.207-3.793 37.000 QUASIPEAK 7 720.000 24.803 6.600 31.403-5.597 37.000 QUASIPEAK 8 959.986 28.347 2.300 30.647-6.353 37.000 QUASIPEAK Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor Page: 94 of 176

5.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Front View of Radiated Test Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Back View of Radiated Test Page: 95 of 176

Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Front View of Radiated Test Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Back View of Radiated Test Page: 96 of 176

Test Mode : Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Front View of Radiated Test Test Mode : Mode 3:MS-6434,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Back View of Radiated Test Page: 97 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Front View of Radiated Test Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Back View of Radiated Test Page: 98 of 176

Test Mode : Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Front View of Radiated Test Test Mode : Mode 5:MS-6429,Intel Pentium IV(LGA 775)3.3GHz/133MHz,D-Sub(1280*1024/85Hz) Description : Back View of Radiated Test Page: 99 of 176

6. Harmonic Current Emission 6.1. Test Specification According to EMC Standard : EN 61000-3-2 6.2. Test Setup 6.3. Limit (a) Limits of Class A Harmonics Currents Harmonics Order n Maximum Permissible harmonic current A Harmonics Order n Maximum Permissible harmonic current A Odd harmonics Even harmonics 3 2.30 2 1.08 5 1.14 4 0.43 7 0.77 6 0.30 9 0.40 8 n 40 0.23 * 8/n 11 0.33 13 0.21 15 n 39 0.15 * 15/n Page: 100 of 176

(b) Limits of Class B Harmonics Currents For Class B equipment, the harmonic of the input current shall not exceed the maximum permissible values given in table that is the limit of Class A multiplied by a factor of 1.5. (c) Limits of Class C Harmonics Currents Harmonics Order Maximum Permissible harmonic current Expressed as a percentage of the input current at the fundamental frequency n % 2 2 3 30.λ * 5 10 7 7 9 5 11 n 39 3 (odd harmonics only) *λ is the circuit power factor (d) Limits of Class D Harmonics Currents Harmonics Order n Maximum Permissible harmonic current per watt ma/w Maximum Permissible harmonic current A 3 3.4 2.30 5 1.9 1.14 7 1.0 0.77 9 0.5 0.40 11 0.35 0.33 11 n 39 (odd harmonics only) 3.85/n See limit of Class A Page: 101 of 176

6.4. Test Procedure The EUT is supplied in series with power analyzer from a power source having the same normal voltage and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be performed. 6.5. Deviation from Test Standard No deviation. Page: 102 of 176

6.6. Test Result Product Barebone Test Item Test Mode Power Harmonics Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/23 Test Site No.3 Shielded Room Test Result: Pass Source qualification: Normal Current & voltage waveforms 3 300 Current (Amps) 2 1 0-1 -2 200 100 0-100 -200 Voltage (Volts) -3-300 Harmonics and Class D limit line European Limits Current RMS(Amps) 0.6 0.5 0.4 0.3 0.2 0.1 0.0 4 8 12 16 20 24 28 32 36 40 Harmonic # Test result: Pass Worst harmonic was #3 with 60.51% of the limit. Page: 103 of 176

Test Result: Pass Source qualification: Normal THC(A): 0.44 I-THD(%): 84.01 POHC(A): 0.010 POHC Limit(A): 0.057 Highest parameter values during test: V_RMS (Volts): 229.73 Frequency(Hz): 50.00 I_Peak (Amps): 2.235 I_RMS (Amps): 0.773 I_Fund (Amps): 0.554 Crest Factor: 3.145 Power (Watts): 133.3 Power Factor: 0.756 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 3 0.377 0.453 83.2 0.360 0.595 60.51 Pass 4 0.000 5 0.191 0.253 75.5 0.204 0.372 54.94 Pass 6 0.000 7 0.090 0.133 67.5 0.098 0.196 50.09 Pass 8 0.000 9 0.054 0.067 81.7 0.058 0.098 59.43 Pass 10 0.000 11 0.020 0.047 43.9 0.020 0.061 33.15 Pass 12 0.000 13 0.004 0.040 9.2 0.004 0.052 7.39 Pass 14 0.000 15 0.005 0.035 14.9 0.005 0.045 11.41 Pass 16 0.000 17 0.006 0.031 19.4 0.006 0.040 15.29 Pass 18 0.000 19 0.004 0.027 14.4 0.004 0.035 11.71 Pass 20 0.000 21 0.005 0.024 21.2 0.005 0.032 15.97 Pass 22 0.000 23 0.003 0.022 15.1 0.003 0.029 11.48 Pass 24 0.000 25 0.005 0.021 25.0 0.005 0.027 19.60 Pass 26 0.000 27 0.003 0.019 14.3 0.003 0.025 13.04 Pass 28 0.000 29 0.003 0.018 17.4 0.004 0.026 13.52 Pass 30 0.000 31 0.003 0.017 15.9 0.003 0.022 12.02 Pass 32 0.000 33 0.002 0.015 15.4 0.003 0.022 11.57 Pass 34 0.000 35 0.002 0.015 16.2 0.003 0.019 13.41 Pass 36 0.000 37 0.001 0.014 7.4 0.002 0.020 7.55 Pass 38 0.000 39 0.002 0.013 18.0 0.002 0.019 13.43 Pass 40 0.000 1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. 2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W. Others the result should be pass. Page: 104 of 176

Product Barebone Test Item Power Harmonics Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/23 Test Site No.3 Shielded Room Test Result: Pass Source qualification: Normal Current & voltage waveforms 3 300 Current (Amps) 2 1 0-1 -2 200 100 0-100 -200 Voltage (Volts) -3-300 Harmonics and Class D limit line European Limits Current RMS(Amps) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 4 8 12 16 20 24 28 32 36 40 Harmonic # Test result: Pass Worst harmonic was #3 with 59.83% of the limit. Page: 105 of 176

Test Result: Pass Source qualification: Normal THC(A): 0.52 I-THD(%): 84.56 POHC(A): 0.010 POHC Limit(A): 0.066 Highest parameter values during test: V_RMS (Volts): 229.74 Frequency(Hz): 50.00 I_Peak (Amps): 2.525 I_RMS (Amps): 0.894 I_Fund (Amps): 0.644 Crest Factor: 3.296 Power (Watts): 153.2 Power Factor: 0.749 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 3 0.446 0.521 85.6 0.464 0.776 59.83 Pass 4 0.000 5 0.231 0.291 79.3 0.243 0.437 55.65 Pass 6 0.000 7 0.114 0.153 74.5 0.121 0.230 52.77 Pass 8 0.000 9 0.065 0.077 84.5 0.068 0.114 59.19 Pass 10 0.000 11 0.021 0.054 38.8 0.021 0.079 26.57 Pass 12 0.000 13 0.004 0.046 8.4 0.004 0.068 6.09 Pass 14 0.000 15 0.005 0.040 12.3 0.005 0.058 8.66 Pass 16 0.000 17 0.005 0.035 14.2 0.005 0.052 10.43 Pass 18 0.000 19 0.003 0.031 10.9 0.004 0.046 7.67 Pass 20 0.000 21 0.005 0.028 18.3 0.005 0.042 12.89 Pass 22 0.000 23 0.003 0.026 12.6 0.004 0.038 9.22 Pass 24 0.000 25 0.005 0.024 19.4 0.005 0.035 14.08 Pass 26 0.000 27 0.002 0.022 8.0 0.002 0.033 6.76 Pass 28 0.000 29 0.004 0.020 18.8 0.004 0.030 13.98 Pass 30 0.000 31 0.002 0.019 11.7 0.002 0.028 8.62 Pass 32 0.000 33 0.002 0.018 13.5 0.003 0.027 10.07 Pass 34 0.000 35 0.002 0.017 10.2 0.002 0.025 7.60 Pass 36 0.000 37 0.002 0.016 12.8 0.002 0.024 9.97 Pass 38 0.000 39 0.002 0.015 13.8 0.002 0.022 9.90 Pass 40 0.000 1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. 2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W. Others the result should be pass. Page: 106 of 176

Product Barebone Test Item Power Harmonics Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/23 Test Site No.3 Shielded Room Test Result: Pass Source qualification: Normal Current & voltage waveforms 3 300 Current (Amps) 2 1 0-1 -2 200 100 0-100 -200 Voltage (Volts) -3-300 Harmonics and Class D limit line European Limits Current RMS(Amps) 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 4 8 12 16 20 24 28 32 36 40 Harmonic # Test result: Pass Worst harmonic was #3 with 59.75% of the limit. Page: 107 of 176

Test Result: Pass Source qualification: Normal THC(A): 0.49 I-THD(%): 84.28 POHC(A): 0.010 POHC Limit(A): 0.062 Highest parameter values during test: V_RMS (Volts): 229.72 Frequency(Hz): 50.00 I_Peak (Amps): 2.329 I_RMS (Amps): 0.840 I_Fund (Amps): 0.608 Crest Factor: 3.322 Power (Watts): 144.7 Power Factor: 0.754 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 3 0.423 0.492 86.1 0.441 0.738 59.75 Pass 4 0.000 5 0.217 0.275 79.1 0.227 0.412 55.13 Pass 6 0.000 7 0.106 0.145 73.3 0.112 0.217 51.53 Pass 8 0.000 9 0.061 0.072 84.7 0.064 0.109 58.94 Pass 10 0.000 11 0.021 0.051 40.6 0.021 0.076 27.48 Pass 12 0.000 13 0.004 0.043 8.5 0.004 0.064 6.00 Pass 14 0.000 15 0.005 0.038 13.3 0.005 0.056 9.34 Pass 16 0.000 17 0.005 0.033 16.2 0.006 0.049 11.41 Pass 18 0.000 19 0.004 0.029 12.0 0.004 0.044 8.53 Pass 20 0.000 21 0.005 0.026 19.7 0.005 0.040 13.78 Pass 22 0.000 23 0.003 0.024 13.5 0.004 0.036 9.67 Pass 24 0.000 25 0.005 0.022 21.5 0.005 0.033 15.43 Pass 26 0.000 27 0.002 0.021 9.6 0.002 0.031 7.69 Pass 28 0.000 29 0.004 0.019 18.9 0.004 0.029 14.05 Pass 30 0.000 31 0.002 0.018 13.5 0.003 0.027 9.78 Pass 32 0.000 33 0.002 0.017 14.2 0.003 0.025 10.59 Pass 34 0.000 35 0.002 0.016 11.8 0.002 0.024 8.80 Pass 36 0.000 37 0.002 0.015 11.8 0.002 0.023 9.44 Pass 38 0.000 39 0.002 0.014 15.9 0.002 0.021 11.48 Pass 40 0.000 1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. 2:According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active input power >75W. Others the result should be pass. Page: 108 of 176

6.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Power Harmonics Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Power Harmonics Test Setup Page: 109 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Power Harmonics Test Setup Page: 110 of 176

7. Voltage Fluctuation and Flicker 7.1. Test Specification According to EMC Standard : EN 61000-3-3 7.2. Test Setup 7.3. Limit The following limits apply: - the value of P st shall not be greater than 1.0; - the value of P lt shall not be greater than 0.65; - the value of d(t) during a voltage change shall not exceed 3.3 % for more than 500 ms; - the relative steady-state voltage change, d c, shall not exceed 3.3 %; - the maximum relative voltage change, d max, shall not exceed; a) 4 % without additional conditions; b) 6 % for equipment which is: - switched manually, or - switched automatically more frequently than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds), or manual restart, after a power supply interruption. NOTE The cycling frequency will be further limited by the P st and P 1t limit. For example: a d max of 6%producing a rectangular voltage change characteristic twice per hour will give a P 1t of about 0.65. Page: 111 of 176

c) 7 % for equipment which is: - attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or - switched on automatically, or is intended to be switched on manually, no more than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual restart, after a power supply interruption. P st and P 1t requirements shall not be applied to voltage changes caused by manual switching. 7.4. Test Procedure The EUT is supplied in series with power analyzer from a power source having the same normal voltage and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be performed. 7.5. Deviation from Test Standard No deviation. Page: 112 of 176

7.6. Test Result Product Barebone Test Item Test Mode Voltage Fluctuation and Flicker Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/23 Test Site No.3 Shielded Room Test Result: Pass Status: Test Completed Pst i and limit line European Limits 1.00 0.75 Pst 0.50 0.25 3:27:36 Plt and limit line Plt 0.6 0.5 0.4 0.3 0.2 0.1 3:27:36 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.44 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass Page: 113 of 176

Product Barebone Test Item Voltage Fluctuation and Flicker Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/23 Test Site No.3 Shielded Room Test Result: Pass Status: Test Completed Pst i and limit line European Limits 1.00 0.75 Pst 0.50 0.25 2:32:00 Plt and limit line Plt 0.6 0.5 0.4 0.3 0.2 0.1 2:32:00 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.56 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass Page: 114 of 176

Product Barebone Test Item Voltage Fluctuation and Flicker Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/23 Test Site No.3 Shielded Room Test Result: Pass Status: Test Completed Pst i and limit line European Limits 1.00 0.75 Pst 0.50 0.25 3:58:57 Plt and limit line Plt 0.6 0.5 0.4 0.3 0.2 0.1 3:58:57 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.43 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.070 Test limit: 0.650 Pass Page: 115 of 176

7.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Flicker Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Flicker Test Setup Page: 116 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Flicker Test Setup Page: 117 of 176

8. Electrostatic Discharge 8.1. Test Specification According to Standard : IEC 61000-4-2 8.2. Test Setup 8.3. Limit Item Environmental Phenomena Units Test Specification Performance Criteria Enclosure Port Electrostatic Discharge kv(charge Voltage) ±8 Air Discharge ±4 Contact Discharge B Page: 118 of 176

8.4. Test Procedure Direct application of discharges to the EUT: Contact discharge was applied only to conductive surfaces of the EUT. Air discharges were applied only to non-conductive surfaces of the EUT. During the test, it was performed with single discharges. For the single discharge time between successive single discharges will be keep longer 1 second. It was at least ten single discharges with positive and negative at the same selected point. The selected point, which was performed with electrostatic discharge, was marked on the red label of the EUT. Indirect application of discharges to the EUT: Vertical Coupling Plane (VCP): The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. Horizontal Coupling Plane (HCP): The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. 8.5. Deviation from Test Standard No deviation. Page: 119 of 176

8.6. Test Result Product Barebone Test Item Test Mode Electrostatic Discharge Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/27 Test Site No.6 Shielded Room Item Amount of Discharge Voltage Required Criteria Complied To Criteria (A,B,C) Results Air Discharge 10 10 +8kV -8kV B B B B Pass Pass Contact Discharge 25 25 +4kV -4kV B B A A Pass Pass Indirect Discharge 50 +4kV B A Pass (HCP) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Front) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Left) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Back) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Right) 50-4kV B A Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. NR: No Requirement Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv. No false alarms or other malfunctions were observed during or after the test. Remark: The Contact discharges were applied at least total 200 discharges at a minimum of four test points. Page: 120 of 176

Product Barebone Test Item Electrostatic Discharge Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/27 Test Site No.6 Shielded Room Item Amount of Discharge Voltage Required Criteria Complied To Criteria (A,B,C) Results Air Discharge 10 10 +8kV -8kV B B B B Pass Pass Contact Discharge 25 25 +4kV -4kV B B A A Pass Pass Indirect Discharge 50 +4kV B A Pass (HCP) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Front) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Left) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Back) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Right) 50-4kV B A Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. NR: No Requirement Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv. No false alarms or other malfunctions were observed during or after the test. Remark: The Contact discharges were applied at least total 200 discharges at a minimum of four test points. Page: 121 of 176

Product Barebone Test Item Electrostatic Discharge Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/27 Test Site No.3 Shielded Room Item Amount of Discharge Voltage Required Criteria Complied To Criteria (A,B,C) Results Air Discharge 10 10 +8kV -8kV B B B B Pass Pass Contact Discharge 25 25 +4kV -4kV B B A A Pass Pass Indirect Discharge 50 +4kV B A Pass (HCP) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Front) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Left) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Back) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Right) 50-4kV B A Pass Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. NR: No Requirement Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv. No false alarms or other malfunctions were observed during or after the test. Remark: The Contact discharges were applied at least total 200 discharges at a minimum of four test points. Page: 122 of 176

8.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : ESD Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : ESD Test Setup Page: 123 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : ESD Test Setup Page: 124 of 176

9. Radiated Susceptibility 9.1. Test Specification According to Standard : IEC 61000-4-3 9.2. Test Setup 9.3. Limit Item Environmental Units Test Performance Phenomena Specification Criteria Enclosure Port Radio-Frequency MHz 80-1000 Electromagnetic Field Amplitude Modulated V/m(Un-modulated, rms) % AM (1kHz) 3 80 A Page: 125 of 176

9.4. Test Procedure The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with one coincident with the calibration plane such that the distance from antenna to the EUT was 3 meters. Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on measurement. In order to judge the EUT performance, a CCD camera is used to monitor EUT screen. All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 3 V/m Level 2 2. Radiated Signal AM 80% Modulated with 1kHz 3. Scanning Frequency 80MHz - 1000MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 9.5. Deviation from Test Standard No deviation. Page: 126 of 176

9.6. Test Result Product Barebone Test Item Test Mode Radiated susceptibility Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/26 Test Site Chamber5 Field Complied Frequency Position Polarity Required Strength To Criteria (MHz) (Angle) (H or V) Criteria (V/m) (A,B,C) Results 80-1000 FRONT H 3 A A PASS 80-1000 FRONT V 3 A A PASS 80-1000 BACK H 3 A A PASS 80-1000 BACK V 3 A A PASS 80-1000 RIGHT H 3 A A PASS 80-1000 RIGHT V 3 A A PASS 80-1000 LEFT H 3 A A PASS 80-1000 LEFT V 3 A A PASS 80-1000 UP H 3 A A PASS 80-1000 UP V 3 A A PASS 80-1000 DOWN H 3 A A PASS 80-1000 DOWN V 3 A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at at frequency MHz. No false alarms or other malfunctions were observed during or after the test. V/m Page: 127 of 176

Product Barebone Test Item Radiated susceptibility Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/26 Test Site Chamber5 Field Complied Frequency Position Polarity Required Strength To Criteria (MHz) (Angle) (H or V) Criteria (V/m) (A,B,C) Results 80-1000 FRONT H 3 A A PASS 80-1000 FRONT V 3 A A PASS 80-1000 BACK H 3 A A PASS 80-1000 BACK V 3 A A PASS 80-1000 RIGHT H 3 A A PASS 80-1000 RIGHT V 3 A A PASS 80-1000 LEFT H 3 A A PASS 80-1000 LEFT V 3 A A PASS 80-1000 UP H 3 A A PASS 80-1000 UP V 3 A A PASS 80-1000 DOWN H 3 A A PASS 80-1000 DOWN V 3 A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at at frequency MHz. No false alarms or other malfunctions were observed during or after the test. V/m Page: 128 of 176

Product Barebone Test Item Radiated susceptibility Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/26 Test Site Chamber5 Field Complied Frequency Position Polarity Required Strength To Criteria (MHz) (Angle) (H or V) Criteria (V/m) (A,B,C) Results 80-1000 FRONT H 3 A A PASS 80-1000 FRONT V 3 A A PASS 80-1000 BACK H 3 A A PASS 80-1000 BACK V 3 A A PASS 80-1000 RIGHT H 3 A A PASS 80-1000 RIGHT V 3 A A PASS 80-1000 LEFT H 3 A A PASS 80-1000 LEFT V 3 A A PASS 80-1000 UP H 3 A A PASS 80-1000 UP V 3 A A PASS 80-1000 DOWN H 3 A A PASS 80-1000 DOWN V 3 A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information There was no observable degradation in performance. EUT stopped operation and could / could not be reset by operator at at frequency MHz. No false alarms or other malfunctions were observed during or after the test. V/m Page: 129 of 176

9.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Radiated Susceptibility Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Radiated Susceptibility Test Setup Page: 130 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Radiated Susceptibility Test Setup Page: 131 of 176

10. Electrical Fast Transient/Burst 10.1. Test Specification According to Standard : IEC 61000-4-4 10.2. Test Setup 10.3. Limit Item Environmental Phenomena I/O and communication ports Fast Transients Common Mode Input DC Power Ports Fast Transients Common Mode Input AC Power Ports Fast Transients Common Mode Units kv (Peak) Tr/Th ns Rep. Frequency khz kv (Peak) Tr/Th ns Rep. Frequency khz kv (Peak) Tr/Th ns Rep. Frequency khz Test Specification Performance Criteria +0.5 5/50 5 +0.5 5/50 5 +1 5/50 5 B B B Page: 132 of 176

10.4. Test Procedure The EUT is placed on a table that is 0.8 meter height. A ground reference plane is placed on the table, and uses a 0.1m insulation between the EUT and ground reference plane. The minimum area of the ground reference plane is 1m*1m, and 0.65mm thick min, and projected beyond the EUT by at least 0.1m on all sides. Test on I/O and communication ports: The EFT interference signal is through a coupling clamp device couples to the signal and control lines of the EUT with burst noise for 1minute. Test on power supply ports: The EUT is connected to the power mains through a coupling device that directly couples the EFT/B interference signal. Each of the Line and Neutral conductors is impressed with burst noise for 1 minute. The length of the signal and power lines between the coupling device and the EUT is 0.5m. 10.5. Deviation from Test Standard No deviation. Page: 133 of 176

10.6. Test Result Product Barebone Test Item Test Mode Electrical fast transient/burst Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/26 Test Site No.2 Shielded Room Inject Line Polarity Voltage kv Inject Time (Second) Inject Method Required Criteria Complied to Criteria Result L+N+PE ± 1kV 60 CDN B B PASS LAN ± 1 kv 90 Clamp B A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at Line. No false alarms or other malfunctions were observed during or after the test. kv of Page: 134 of 176

Product Barebone Test Item Electrical fast transient/burst Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/26 Test Site No.2 Shielded Room Inject Line Polarity Voltage kv Inject Time (Second) Inject Method Required Criteria Complied to Criteria Result L+N+PE ± 1kV 60 CDN B B PASS LAN ± 1 kv 90 Clamp B A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at Line. No false alarms or other malfunctions were observed during or after the test. kv of Page: 135 of 176

Product Barebone Test Item Electrical fast transient/burst Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/26 Test Site No.2 Shielded Room Inject Line Polarity Voltage kv Inject Time (Second) Inject Method Required Criteria Complied to Criteria Result L+N+PE ± 1kV 60 CDN B B PASS LAN ± 1 kv 90 Clamp B A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at Line. No false alarms or other malfunctions were observed during or after the test. kv of Page: 136 of 176

10.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : EFT/B Test Setup Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : EFT/B Test Setup - Clamp Page: 137 of 176

Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : EFT/B Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : EFT/B Test Setup - Clamp Page: 138 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : EFT/B Test Setup Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : EFT/B Test Setup - Clamp Page: 139 of 176

11. Surge 11.1. Test Specification According to Standard : IEC 61000-4-5 11.2. Test Setup 11.3. Limit Item Environmental Phenomena Units Signal Ports and Telecommunication Ports(See 1) and 2) ) Surges Tr/Th us Line to Ground kv Input DC Power Ports Surges Tr/Th us Line to Ground kv AC Input and AC Output Power Ports Surges Tr/Th us Line to Line kv Line to Ground kv Notes: Test Specification Performance Criteria 1.2/50 (8/20) ± 1 1.2/50 (8/20) ± 0.5 1.2/50 (8/20) ± 1 ± 2 1) Applicable only to ports which according to the manufacturer s may directly to outdoor cables. 2) Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no immunity test shall be required. B B B Page: 140 of 176

11.4. Test Procedure The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The length of power cord between the coupling device and the EUT shall be 2m or less. For Input and Output AC Power or DC Input and DC Output Power Ports: The EUT is connected to the power mains through a coupling device that directly couples the Surge interference signal. The surge noise shall be applied synchronized to the voltage phase at 0 0, 90 0, 180 0, 270 0 and the peak value of the a.c. voltage wave. (Positive and negative) Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with interval of 1 min. 11.5. Deviation from Test Standard No deviation. Page: 141 of 176

11.6. Test Result Product Barebone Test Item Test Mode Surge Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/23 Test Site No.6 Shielded Room Inject Line Polarity Angle Voltage kv Time Interval (Second) Inject Method Required Criteria Complie d to Criteria Result L-N ± 0 1kV 60 Direct B A PASS L-N ± 90 1kV 60 Direct B A PASS L-N ± 180 1kV 60 Direct B A PASS L-N ± 270 1kV 60 Direct B A PASS L-PE ± 0 2kV 60 Direct B A PASS L-PE ± 90 2kV 60 Direct B A PASS L-PE ± 180 2kV 60 Direct B A PASS L-PE ± 270 2kV 60 Direct B A PASS N-PE ± 0 2kV 60 Direct B A PASS N-PE ± 90 2kV 60 Direct B A PASS N-PE ± 180 2kV 60 Direct B A PASS N-PE ± 270 2kV 60 Direct B A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. Page: 142 of 176

Product Barebone Test Item Surge Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/23 Test Site No.6 Shielded Room Voltage Time Complie Inject Inject Required Polarity Angle Interval d to Line Method Criteria kv (Second) Criteria Result L-N ± 0 1kV 60 Direct B A PASS L-N ± 90 1kV 60 Direct B A PASS L-N ± 180 1kV 60 Direct B A PASS L-N ± 270 1kV 60 Direct B A PASS L-PE ± 0 2kV 60 Direct B A PASS L-PE ± 90 2kV 60 Direct B A PASS L-PE ± 180 2kV 60 Direct B A PASS L-PE ± 270 2kV 60 Direct B A PASS N-PE ± 0 2kV 60 Direct B A PASS N-PE ± 90 2kV 60 Direct B A PASS N-PE ± 180 2kV 60 Direct B A PASS N-PE ± 270 2kV 60 Direct B A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. Page: 143 of 176

Product Barebone Test Item Surge Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/23 Test Site No.6 Shielded Room Voltage Time Complie Inject Inject Required Polarity Angle Interval d to Line Method Criteria kv (Second) Criteria Result L-N ± 0 1kV 60 Direct B A PASS L-N ± 90 1kV 60 Direct B A PASS L-N ± 180 1kV 60 Direct B A PASS L-N ± 270 1kV 60 Direct B A PASS L-PE ± 0 2kV 60 Direct B A PASS L-PE ± 90 2kV 60 Direct B A PASS L-PE ± 180 2kV 60 Direct B A PASS L-PE ± 270 2kV 60 Direct B A PASS N-PE ± 0 2kV 60 Direct B A PASS N-PE ± 90 2kV 60 Direct B A PASS N-PE ± 180 2kV 60 Direct B A PASS N-PE ± 270 2kV 60 Direct B A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. Page: 144 of 176

11.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : SURGE Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : SURGE Test Setup Page: 145 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : SURGE Test Setup Page: 146 of 176

12. Conducted Susceptibility 12.1. Test Specification According to Standard : IEC 61000-4-6 12.2. Test Setup CDN Test Mode EM Clamp Test Mode Page: 147 of 176

12.3. Limit Item Environmental Phenomena Units Signal Ports and Telecommunication Ports Radio-Frequency Continuous Conducted Input DC Power Ports Radio-Frequency Continuous Conducted Input AC Power Ports Radio-Frequency Continuous Conducted 12.4. Test Procedure MHz V (rms, Un-modulated) % AM (1kHz) MHz V (rms, Un-modulated) % AM (1kHz) MHz V (rms, Un-modulated) % AM (1kHz) Test Specification 0.15-80 3 80 0.15-80 3 80 0.15-80 3 80 Performance Criteria A A A The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table, EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane. For Signal Ports and Telecommunication Ports The disturbance signal is through a coupling and decoupling networks (CDN) or EM-clamp device couples to the signal and Telecommunication lines of the EUT. For Input DC and AC Power Ports The EUT is connected to the power mains through a coupling and decoupling networks for power supply lines. And directly couples the disturbances signal into EUT. Used CDN-M2 for two wires or CDN-M3 for three wires. All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 130dBuV(3V) Level 2 2. Radiated Signal AM 80% Modulated with 1kHz 3. Scanning Frequency 0.15MHz 80MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 12.5. Deviation from Test Standard No deviation. Page: 148 of 176

12.6. Test Result Product Barebone Test Item Test Mode Conducted susceptibility Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/26 Test Site No.6 Shielded Room Frequency Voltage Inject Tested Port Required Performanc Result Range Applied Method of Criteria e Criteria (MHz) dbuv(v) EUT Complied To 0.15~80 130 (3V) CDN AC IN A A PASS 0.15~80 130 (3V) CDN LAN A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at dbuv(v) at frequency MHz. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 149 of 176

Product Barebone Test Item Conducted susceptibility Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/26 Test Site No.6 Shielded Room Frequency Voltage Inject Tested Port Required Performanc Result Range Applied Method of Criteria e Criteria (MHz) dbuv(v) EUT Complied To 0.15~80 130 (3V) CDN AC IN A A PASS 0.15~80 130 (3V) CDN LAN A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at dbuv(v) at frequency MHz. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 150 of 176

Product Barebone Test Item Conducted susceptibility Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/26 Test Site No.6 Shielded Room Frequency Voltage Inject Tested Port Required Performanc Result Range Applied Method of Criteria e Criteria (MHz) dbuv(v) EUT Complied To 0.15~80 130 (3V) CDN AC IN A A PASS 0.15~80 130 (3V) CDN LAN A A PASS Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at dbuv(v) at frequency MHz. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 151 of 176

12.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Conducted Susceptibility Test Setup Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Conducted Susceptibility Test Setup - CDN Page: 152 of 176

Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Conducted Susceptibility Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Conducted Susceptibility Test Setup - CDN Page: 153 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Conducted Susceptibility Test Setup Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Conducted Susceptibility Test Setup - CDN Page: 154 of 176

13. Power Frequency Magnetic Field 13.1. Test Specification According to Standard : IEC 61000-4-8 13.2. Test Setup 13.3. Limit Item Environmental Phenomena Enclosure Port Power-Frequency Magnetic Field 13.4. Test Procedure Units Hz A/m (r.m.s.) Test Specification Performance Criteria 50 1 A The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured at least 1m*1m min. The test magnetic field shall be placed at central of the induction coil. The test magnetic Field shall be applied 10 minutes by the immersion method to the EUT. And the induction coil shall be rotated by 90 in order to expose the EUT to the test field with different orientation (X, Y, Z Orientations). 13.5. Deviation from Test Standard No deviation. Page: 155 of 176

13.6. Test Result Product Barebone Test Item Test Mode Power frequency magnetic field Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/27 Test Site No.3 Shielded Room Polarization Frequency Magnetic Required Performance Test Result (Hz) Strength Performance Criteria (A/m) Criteria Complied To X Orientation 50 1 A A PASS Y Orientation 50 1 A A PASS Z Orientation 50 1 A A PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. kv Page: 156 of 176

Product Barebone Test Item Power frequency magnetic field Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/27 Test Site No.3 Shielded Room Polarization Frequency Magnetic Required Performance Test Result (Hz) Strength Performance Criteria (A/m) Criteria Complied To X Orientation 50 1 A A PASS Y Orientation 50 1 A A PASS Z Orientation 50 1 A A PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. kv Page: 157 of 176

Product Barebone Test Item Power frequency magnetic field Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/27 Test Site No.3 Shielded Room Polarization Frequency Magnetic Required Performance Test Result (Hz) Strength Performance Criteria (A/m) Criteria Complied To X Orientation 50 1 A A PASS Y Orientation 50 1 A A PASS Z Orientation 50 1 A A PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. kv Page: 158 of 176

13.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Power Frequency Magnetic Field Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Power Frequency Magnetic Field Test Setup Page: 159 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Power Frequency Magnetic Field Test Setup Page: 160 of 176

14. Voltage Dips and Interruption 14.1. Test Specification According to Standard : IEC 61000-4-11 14.2. Test Setup 14.3. Limit Item Environmental Phenomena Input AC Power Ports Voltage Dips Voltage Interruptions Units % Reduction Period % Reduction Period % Reduction Period Test Specification Performance Criteria 30 C 25 >95 B 0.5 > 95 C 250 Page: 161 of 176

14.4. Test Procedure The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured 1m*1m min. And 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The power cord shall be used the shortest power cord as specified by the manufacturer. For Voltage Dips/ Interruptions test: The selection of test voltage is based on the rated power range. If the operation range is large than 20% of lower power range, both end of specified voltage shall be tested. Otherwise, the typical voltage specification is selected as test voltage. The EUT is connected to the power mains through a coupling device that directly couples to the Voltage Dips and Interruption Generator. The EUT shall be tested for 30% voltage dip of supplied voltage and duration 25 Periods, for 95% voltage dip of supplied voltage and duration 0.5 Periods with a sequence of three voltage dips with intervals of 10 seconds, and for 95% voltage interruption of supplied voltage and duration 250 Periods with a sequence of three voltage interruptions with intervals of 10 seconds. Voltage phase shifting are shall occur at 0 0, 45 0, 90 0,135 0,180 0,225 0, 270 0,315 0 of the voltage. 14.5. Deviation from Test Standard No deviation. Page: 162 of 176

14.6. Test Result Product Barebone Test Item Test Mode Voltage dips and interruption Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Date of Test 2006/09/26 Test Site No.6 Shielded Room Voltage Dips and Interruption Reduction(%) Angle Test Duration (Periods) Required Performance Criteria Performance Test Result Criteria Complied To 30(161V) 0 25 C A PASS 30(161V) 45 25 C A PASS 30(161V) 90 25 C A PASS 30(161V) 135 25 C A PASS 30(161V) 180 25 C A PASS 30(161V) 225 25 C A PASS 30(161V) 270 25 C A PASS 30(161V) 315 25 C A PASS >95(0V) 0 0.5 B A PASS >95(0V) 45 0.5 B A PASS >95(0V) 90 0.5 B A PASS >95(0V) 135 0.5 B A PASS >95(0V) 180 0.5 B A PASS >95(0V) 225 0.5 B A PASS >95(0V) 270 0.5 B A PASS >95(0V) 315 0.5 B A PASS >95(0V) 0 250 C C PASS >95(0V) 45 250 C C PASS >95(0V) 90 250 C C PASS >95(0V) 135 250 C C PASS >95(0V) 180 250 C C PASS >95(0V) 225 250 C C PASS >95(0V) 270 250 C C PASS >95(0V) 315 250 C C PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 163 of 176 kv

Product Barebone Test Item Voltage dips and interruption Test Mode Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Date of Test 2006/09/26 Test Site No.6 Shielded Room Voltage Dips and Interruption Reduction(%) Angle Test Duration (Periods) Required Performance Criteria Performance Test Result Criteria Complied To 30(161V) 0 25 C A PASS 30(161V) 45 25 C A PASS 30(161V) 90 25 C A PASS 30(161V) 135 25 C A PASS 30(161V) 180 25 C A PASS 30(161V) 225 25 C A PASS 30(161V) 270 25 C A PASS 30(161V) 315 25 C A PASS >95(0V) 0 0.5 B A PASS >95(0V) 45 0.5 B A PASS >95(0V) 90 0.5 B A PASS >95(0V) 135 0.5 B A PASS >95(0V) 180 0.5 B A PASS >95(0V) 225 0.5 B A PASS >95(0V) 270 0.5 B A PASS >95(0V) 315 0.5 B A PASS >95(0V) 0 250 C C PASS >95(0V) 45 250 C C PASS >95(0V) 90 250 C C PASS >95(0V) 135 250 C C PASS >95(0V) 180 250 C C PASS >95(0V) 225 250 C C PASS >95(0V) 270 250 C C PASS >95(0V) 315 250 C C PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. kv Page: 164 of 176

Product Barebone Test Item Voltage dips and interruption Test Mode Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Date of Test 2006/09/26 Test Site No.6 Shielded Room Voltage Dips and Interruption Reduction(%) Angle Test Duration (Periods) Required Performance Criteria Performance Test Result Criteria Complied To 30(161V) 0 25 C A PASS 30(161V) 45 25 C A PASS 30(161V) 90 25 C A PASS 30(161V) 135 25 C A PASS 30(161V) 180 25 C A PASS 30(161V) 225 25 C A PASS 30(161V) 270 25 C A PASS 30(161V) 315 25 C A PASS >95(0V) 0 0.5 B A PASS >95(0V) 45 0.5 B A PASS >95(0V) 90 0.5 B A PASS >95(0V) 135 0.5 B A PASS >95(0V) 180 0.5 B A PASS >95(0V) 225 0.5 B A PASS >95(0V) 270 0.5 B A PASS >95(0V) 315 0.5 B A PASS >95(0V) 0 250 C C PASS >95(0V) 45 250 C C PASS >95(0V) 90 250 C C PASS >95(0V) 135 250 C C PASS >95(0V) 180 250 C C PASS >95(0V) 225 250 C C PASS >95(0V) 270 250 C C PASS >95(0V) 315 250 C C PASS Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at of Line. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. kv Page: 165 of 176

14.7. Test Photograph Test Mode : Mode 1:MS-6437,AMD AM2 Sempron 3400+,D-Sub(2048*1536/60Hz) Description : Voltage Dips Test Setup Test Mode : Mode 2:MS-6434,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(1920*1440/60Hz) Description : Voltage Dips Test Setup Page: 166 of 176

Test Mode : Mode 4:MS-6429,Intel Pentium IV(LGA 775)3.4GHz/200MHz,D-Sub(2048*1536/75Hz) Description : Voltage Dips Test Setup Page: 167 of 176

15. Attachment EUT Photograph (1) EUT Photo (MS-6437) (2) EUT Photo Page: 168 of 176

(3) EUT Photo (4) EUT Photo Page: 169 of 176

(5) EUT Photo (6) EUT Photo (MS-6434) Page: 170 of 176

(7) EUT Photo (8) EUT Photo Page: 171 of 176

(9) EUT Photo (10) EUT Photo Page: 172 of 176

(11) EUT Photo (MS-6429) (12) EUT Photo Page: 173 of 176

(13) EUT Photo (14) EUT Photo Page: 174 of 176

(15) EUT Photo (16) EUT Photo Page: 175 of 176

(17) EUT Photo (18) EUT Photo Page: 176 of 176