Multidimensional Imaging with the Opterra Multipoint Scanning Confocal System

Similar documents
Spectral Imaging with the Opterra Multipoint Scanning Confocal

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging

Swept-Field User Guide

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Multifluorescence The Crosstalk Problem and Its Solution

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

Confocal Microscopy. (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7. November 2017

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

More fancy SPIM, Even fancier SPIM

Inside the LSM 880 NLO + Airyscan

Nature Methods: doi: /nmeth Supplementary Figure 1

Nikon A1Rsi Confocal Start-Up Sequence

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Components of confocal and two-photon microscopes

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

VivaTome. Discover the Dynamics of Life. The Entry-level System that Captures Dynamic Processes with Outstanding Image Quality.

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes

3 Choose the Channels button and set the Channel Settings. Set the Pinhole to 1 Airy unit.

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Technology Note ZEISS LSM 880 with Airyscan

Application Note. The New 2D Superresolution Mode for ZEISS Airyscan 120 nm Lateral Resolution without Acquiring a Z-stack

Leica SP8 Resonant Confocal. Quick-Start Guide

Leica Sp5 II Confocal User Guide

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

SPINNING DISK CSU-X1 USER MANUAL

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

長庚大學共軛焦顯微鏡課程 長庚大學共軛焦顯微鏡課程. Spot light 長庚大學

Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup.

Dynamic Confocal Imaging of Living Brain. Advantages and risks of multiphoton microscopy in physiology

Instant super-resolution imaging in live cells and embryos via analog image processing

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

Leica TCS SP8 Quick Start Guide

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Final Exam, 150 points PMB 185: Techniques in Light Microscopy

ZEISS LSM510META confocal manual

Quick Start Guide. Leica SP5 X

1.The Problem LIGHT-LEVEL LEVEL IMAGING. light-level level Cameras. 3. Solutions. 2. Low-light LOW-LIGHT

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

FEMTOSMART. Benefits. Features

BASICS OF CONFOCAL IMAGING (PART I)

Competition for the Confocal Microscope?

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

ADVANCED METHODS FOR CONFOCAL MICROSCOPY II. Jean-Yves Chatton Sept. 2006

The Zeiss AiryScan System, Confocal Four.

Zeiss Axio Imager.A1 manual

Supplemental Method Information Zeiss LSM710

Practical work no. 3: Confocal Live Cell Microscopy

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

Microscope Confocal Sp2 Upright.

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

Microscopy from Carl Zeiss

3D light microscopy techniques

Shreyash Tandon M.S. III Year

Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK

Leica TCS SP8 Quick Start Guide

Zeiss LSM 780 Protocol

Multicolor two-photon light-sheet microscopy Pierre Mahou, Julien Vermot, Emmanuel Beaurepaire & Willy Supatto

Zeiss 780 Training Notes

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Zeiss 880 Training Notes Zen 2.3

Title: Nikon A1R Confocal User Manual

Deep and fast live imaging with two-photon scanned light-sheet microscopy

Introduction to light microscopy

Widefield 1. Switching on

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging.

Modes of light microscopy Choosing the appropriate system

Confocal Microscopy. Kristin Jensen

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Nature Methods: doi: /nmeth Supplementary Figure 1. Comparison of HySP and linear unmixing under different signal-to-noise ratios (SNRs).

The DCS-120 Confocal Scanning FLIM System

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

NIS-Elements C (For CONFOCAL MICROSCOPE A1) Instructions (Ver. 4.40)

personal DELTAVISION (pdv)

Title: Leica SP5 Confocal User Manual

In-Vivo Imaging: IVIS Lumina XR. William R. Anderson IVIS Product Specialist

Basics of confocal imaging (part I)

DSU Spinning Disk Confocal and Slidebook 4.2 Quick Guide Light Microscopy Core Facility University of Chicago Vers 0.

Fixed cell DSU Spinning Disk Confocal and Slidebook 5.0 Quick Guide. Light Microscopy Core Facility University of Chicago Vers 1.

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

High-resolution, low light-dose lightsheet microscope LATTICE LIGHTSHEET

Comparing FCS and FRAP as methodologies for calculating diffusion

LSM 780 Confocal Microscope Standard Operation Protocol

Megapixel FLIM with bh TCSPC Modules

Instructions for the Experiment

MOM#3: LIGHT SHEET MICROSCOPY (LSM) Stanley Cohen, MD

Confocal, hyperspectral, spinning disk

Welcome to: LMBR Imaging Workshop. Imaging Fundamentals Mike Meade, Photometrics

User manual for Olympus SD-OSR spinning disk confocal microscope

Zeiss LSM 880 Protocol

MetaMorph Imaging Handbook Update 6/4/13

Development of a High-speed Super-resolution Confocal Scanner

Multiphoton confocal microscope. Multiphoton confocal microscope A1R MP

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Things to check before start-up.

Transcription:

Multidimensional Imaging with the Opterra Multipoint Scanning Confocal System

Outline Opterra design overview Light Path Scan Modes Performance Application data Drosophila larva heart. Courtesy of Nikon

Opterra allows you to pick your position in the Iron Triangle of Imaging Figure courtesy of Paul Maddox Concept originally developed by Jonas Dorn and Gaudenz Danuser 10/30/2014 3

Opterra Design Overview Two modes of operation Variable pinhole, linear array field scanner. Supravideo rate, high speed slit scanner. EMCCD camera-based detector. High frequency scanning minimizes phototoxicity and photobleaching Multiple scan modes allow for optimization of resolution, speed and light delivery Linear pinholes and separate light paths for emission and excitation minimize emission crosstalk

Overhead View of Opterra Imaging Scanner Showing Lightpath 10/30/2014 Bruker Confidential 5

Galvanometer and Piezos Camera side piezo Galvanometer Scope side piezo 10/30/2014 6

Aperture plate

Opterra Aperture Positions Slit scanning positions Pinhole scanning positions 22 mm slit 35 mm slit 50 mm slit 70 mm slit 30 mm pinholes (x32) 45 mm pinholes (x32) 60 mm pinholes (x32)

Opterra Imaging Scanner Light Path

Galvo moves a fixed distance Time to move depends on exposure time Galvanometer and Piezo Movement Piezos move a fixed distance Time to move depends on exposure time It takes 2 frames for one complete piezo sweep Galvo sweeps multiple cycles/frame, and piezos sweep only once per frame

Galvanometer and Piezo Movement Field-scanning combines multiple galvo sweeps with bidirectional piezo movement

Scan pattern timing

Cross talk Linear pinhole arrangement: < one half of the crosstalk of 2-D array scanners. Provides improved axial resolution.

Performance Standard Opterra camera (Evolve Delta) 512 x 512 full frame acquisition. Up to 40 full frames per second pinhole mode. Faster acquisition from smaller region of interest. Slit scan imaging at 66 fps full frame (512x512), 500 fps with ROI, up to 1000 fps with specialized detector

Opterra benefits for Multidimensional Imaging Less cross talk provides improved axial resolution and imaging depth High acquisition speed provides excellent temporal resolution Shorter exposure times results in lower phototoxicity and photobleaching Sea urchin embryos, 50 plane Z series every 2 minutes, experiments for over 2 hours compare to 1 hour on spinning disc Generally across a number of samples exposures 5 10 times shorter than spinning discs

Zebrafish Neurons 100 um Z Range Opterra confocal

Tumor Slice CFP and GFP label 100 um Z range

Z Series Collected on Timed Intervals Max projections of Z series timelapse,rab5-gfp vesicles in axons within spinal cord of intact Zebrafish embryo. -. -. 12 section z series Less than 1 second per Z stack Z every 5 seconds 10/30/2014 18

Z Series Timelapse Green: EGFP labelled EB3, Red H2B mcherry Max projections, 5 seconds intervals, 21 plane stacks, 0.5 um spacing 2014 MBL AQLM 10/30/2014 19

Max projection of high speed z series YFP mitochondria, mcherry peroxisomes Max projection of high speed z series 11 Planes, 0.3 micron spacing 2 Color 1.2 seconds / Z stack Z every 2 seconds 10/30/2014 20

Atlas Imaging for Stage Montages 10/30/2014 21

Moving using the Atlas Window 10/30/2014 22

10/30/2014 23 Changing Focus Focal plane can be changed using: Click and drag on Z slice (shown) Mouse scroll wheel Prairie View s existing Z controls Wheels on motor controlling hardware

Atlas Imaging Pruning the Grid 10/30/2014 24

Arabidopsis 2x4 montage, 60x objective 10/30/2014 Bruker Confidential 25

Tissue section, 2.4 mm by 1.2 mm area at 60 x 18x9 montage 10/30/2014 Bruker Confidential 26

Opterra Multipoint Scanning Confocal Summary Flexibility in aperture selection to meet experimental needs, allows user to balance speed, resolution and sensitivity. Allows the user to determine where they want to be in the Iron Triangle of Imaging Pinholes in 1-D array minimizes cross talk and improves axial resolution compared to 2-D arrays Scanning pattern with pinholes minimizes phototoxicity Speed provides high temporal resolution with 4-D imaging Higher throughput on grid collection applications 10/30/2014 Bruker Confidential 27

Copyright Bruker Corporation. All rights reserved. www.bruker.com