DATA SHEET. Switchboard instruments,

Similar documents
DATA SHEET. Voltmeters and Ammeters,

TCM-2 Thyristor Control Module DATA SHEET

DATA SHEET Selectable AC transducer TAS-311DG

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

EA16, EB16, EA17, EA19

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Analogue Meters BQ0x07 series BQ - Moving-coil Panel instruments BQ0107, BQ0207, BQ0307, BQ0407 & BQ0507 1)

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

Function. Adjustment. Extra functions included. Modes. Housing

Automatic synchronising relay

RMV-122D, RMV-132D ANSI

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Analogue Meters CQ0x07 series

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

RS Pro ENGLISH. Datasheet

Basic Series Square Panel Meters Features Benefits

Analog Panel Meters Preference Program Basic Series Vario Series

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Summation current transformers, type KSU/SUSK

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

Technical Data Sheet. x1000. kwh R Y B

Price List w.e.f 1st October 2018

RS Pro ENGLISH. Datasheet

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144

Standard Program Technical Description

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

BE96-V BE96-A BE96-HZ. AC Voltmeters (moving iron) ~A

ANALOGUE PANEL METERS. GMW We make your values visible Basic Series

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

AMIK 200 / 201 Technical Data Sheet

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

RISH Ducer E13 3 channel transducer for AC current and voltage

For Immediate Delivery call KMParts.com at (866)

Analog Panel Meters Preference Program Basic Series Vario Series

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

CP-T range Benefits and advantages

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Measuring current transformers of the W, W series

CP-T range Product group picture

Jewell DPM EINE BEST IN CLASS

Technical Data Sheet AMIK 300 / 301

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Installation / Monitoring Technique

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

EURAX UI 505, Combined Transducer for AC current and AC voltage

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Flexible AC current probes

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

27/04/2015

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Three-phase monitoring relay CM-PFS

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Digital Multifunction Instrument - Rish Master 3440

Data Sheet. RISH Master Record %THD

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Electronic timer CT-SDS.22

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Power supply CP-E 24/2.5


Medium Voltage Products. KECA 80 C85 Indoor current sensor

Overcurrent Protection / 7SJ45

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

QUINT-PS-24DC/24DC/10

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

Instantaneous Overcurrent Relay

CP-E range Benefits and advantages

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

LINAX 4000L Continuous-line recorder

Transcription:

DATA SHEET Switchboard instruments, types Standard DIN sizes Quadratic instruments: Q48 Q144 Edgewise instruments: 48 x 24 144 x 72 mm Slim edgewise instruments: 72 x 24 144 x 36 mm Accuracy class 1.5 Exchangeable scale (quadratic instruments) Document no.: 4921210012P

Contents Special versions... page 2 General technical specifications... page 3 Quadratic moving coil instruments with/without rectifier... page 4 Quadratic moving iron instruments... page 6 Edgewise moving coil instruments... page 8 Slim edgewise moving coil instruments... page 10 Dimensional details... page 12 Available types Quadratic instruments 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm Moving coil 90 DQ48-x DQ72-x DQ96-x DQ144-x Moving coil 240 DQ48-c DQ72-c DQ96-c DQ144-c DQ48-xc DQ72-xc DQ96-xc DQ144-xc - with rectifier 90 VDQ72-x VDQ96-x VDQ144-x - with rectifier 240 VDQ72-c VDQ96-c VDQ144-c VDQ72-xc VDQ96-xc VDQ144-xc Moving iron 90 EQ48-x EQ72-x EQ96-x EQ144-x Edgewise instruments 48 x 24 mm 72 x 36 mm 96 x 48 mm 144 x 72 mm Moving coil DPR48 DPR72 DPR96 DPR144 Slim edgewise instruments 72 x 24 mm 96 x 24 mm 144 x 36 mm Moving coil DSM72 DSM96 DSM144 Special versions General Scale Moving iron instruments Anti-glare glass IP54 from front (incl. rubber gasket) (types DQ and EQ) Adjustable red pointer (types Q48-x, Q72-x, Q96-x, Q144-x) (IP52) Other measuring ranges than those stated in this data sheet Non-standard scale e.g. ammeter with 3, 4, 5 or 6 times overload range Scale according to table or curve Single scale with double row of figures (standard scale) Double scale with 2 rows of figures (standard divisions) Single scale with fine divisions for standard pointer Optional graphics: E.g. a red line, own logo, specific numbers/figures, coloured section, two rows of numbers Adjusted to a specified frequency, 100...500 Hz (only necessary for voltmeters) Adjusted for DC measurement Moving coil instruments Suppressed zero (DQ..-x/DQ..-c/-xc: max. 20%) Zero at centre of scale or the like Integrated adjustment potentiometer (±10% standard, up to ±50% on request) Adjusted to accuracy class 1.0 (not possible for type Q48) Accessories: Blank covers types Q72, Q96, Q144 Blank covers are typically applied to cover panel cut-outs provided for later extension of the switchboard. The blank covers consist of a standard bezel with spring clamp for mounting in the panel, mounted with a white, opal PVC plate instead of glass. (Depth behind panel: approx. 12 mm). DEIF A/S Page 2 of 12

General technical specifications Accuracy Instruments are designed according to below mentioned standards Class 1.5 (-10...15...30...55 C) Linear scales: ±1.5% of full scale value (FS) Standards EN 60051 and IEC 51 Non-linear scales: ±1.5% of scale length 48 x 24 mm 72 x 24 mm 96 x 24 mm 144 x 36 mm Instrument sizes 72 x 36 mm 96 x 48 mm 144 x 72 mm DIN 43700 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm Bezels Slim bezels DIN 43718 Scale/pointer Standard pointer DIN 43802 Standard: Vertical (90 ±5 ) Other angles: Specify angle to horizontal vertical mounting Mounting angle 60 60 to horizontal (e.g.) DIN 16257 Π horizontal mounting For edgewise instruments only, furthermore specify: Horizontal or vertical scale Measuring ranges See pages 4-10. Others on request. DIN 43701 Protection Standard version IP54 version * * ) Marked with label: (Housings) From front From rear From front From rear "IP54 from front only when rubber gasket is IP52 IP52 IP54 IP52 mounted" Quadratic Edgewise Quadratic Edgewise (Terminals) IP20 IP00 IP20 IP00 IEC 529 and EN 60529 Climate Class HUE Short-term condensing allowed DIN 40040 Max. 95% RH: Max. 30 days per year Max. 85% RH: Remaining days Max. 75% RH: Average per year -10...55 C (nominal) Temperature -25...60 C (operating) EN 60051 and IEC 51-25...65 C (storage) Panel influence The accuracy is affected neither by the material nor by the thickness of the panel EN 60051 and IEC 51 15 g - 6 times - 3 directions Shock test 50 g/6 ms IEC 68-2-27, Test: Ea 22 g/20 ms Vibrations 3-13.2 Hz: 3 mm GL + LR: Test 1 13.2-100 Hz: 1 g DNV: Class A Materials All plastic materials are self-extinguishing UL94 (V0) For detailed information: Please see the individual types Safety Pollution deg. 2 Quadratic instruments are supplied with protective cover fitted EN 61010-1 over terminals EMC CE-classified for residential, commercial and light industry plus EN 61000-6-3/4 industrial environment EN 61000-6-1/2 DEIF A/S Page 3 of 12

Quadratic moving coil instruments (DQ) Application: Measurement of DC currents and DC voltages Scale: Linear Scale lengths: DQ48/72/96/144-x: 41/62/92/135 mm DQ48/72/96/144-xc/-c: 75/113/151/230 mm Accuracy: Class 1.5 Burdens: Voltmeters: 1 ma, R i : 1 kω/v Ammeters: Ammeters: 60 mv...0.5 V 4 20 ma (see note 3 below) Housings: Plastic V 100 40 60 40 60 50 20 80 20 80 0 % 100 0 100 0 % DQ96-x (exchangeable scale) DQ96-c (non-exch. scale) DQ96-xc (exchangeable scale) Type Size (mm) Measuring range - V 1) 2) 1) 2) Measuring range - A DQ48-x DQ72-x DQ96-x DQ144-x DQ48-xc/DQ48-c DQ72-xc/DQ72-c DQ96-xc/DQ96-c DQ144-xc/DQ144-c 48 x 48 72 x 72 96 x 96 144 x 144 48 x 48 72 x 72 96 x 96 144 x 144 1 ma... 600 ma, 4...20 ma 3) 1 ma... 5-10-15-40 A, 4...20 ma 3) 1 ma... 5-10-15-40 A, 4...20 ma 3) 1 ma... 5-10-15-40 A, 4...20 ma 3) 1 ma... 600 ma, 4...20 ma 3) 1 ma... 5-10-15-40 A, 4...20 ma 3) 1 ma... 5-10-15-40 A, 4...20 ma 3) 1 ma... 5-10-15-40 A, 4...20 ma 3) 1) Standard measuring ranges: 1-1.2-1.5-2 - 2.5-3 - 4-5 - 6-8 and multiples of 10 thereof 2) Safety Cat. III 300 V max. (515 V ph-ph (300 x 3)) 3) 4 20 ma: Electrically suppressed, voltage drop at 20 ma = 1.6 V for -x and 1.80 V for -c/-xc Quadratic moving coil instruments with rectifier Application: Measurement of AC currents and AC voltages. Measures average value, calibrated to R.M.S. value at sinusoidal current/voltage VDQ.. Voltmeters 25...300 V: R i : Approx. 1 kω/v. Range <50V AC: Scale non-linear Max. 515 V derived from voltages with max. 300 V to earth (300 V cat. III/600 V cat. II) VDQ.. Ammeters 1...600 ma: Voltage drop: Approx. 1.2 V DEIF A/S Page 4 of 12

Available variants Item no. no. description 2961010420 01 DQ48-x All measuring inputs, without scale 2961010420 02 DQ48-x All measuring inputs, with standard scale 2961010420 03 DQ48-x Measuring input 4-20 ma DC with customised scale and anti-glare glass 2961060420 01 DQ48-c/-xc All measuring inputs, without scale 2961060420 02 DQ48-c/-xc All measuring inputs, with standard scale 2961010720 01 DQ72-x All measuring inputs, without scale 2961010720 02 DQ72-x All measuring inputs, with standard scale 2961010720 03 DQ72-x Direct current measurement with standard scale 2961060720 01 DQ72-c/-xc All measuring inputs, without scale 2961060720 02 DQ72-c/-xc All measuring inputs, with standard scale 2961060720 03 DQ72-c/-xc Direct current measurement with standard scale 2961010920 01 DQ96-x All measuring inputs, without scale 2961010920 02 DQ96-x All measuring inputs, with standard scale 2961010920 03 DQ96-x Direct current measurement with standard scale 2961010920 04 DQ96-x Measuring input 4-20 ma with customised scale incl. anti-glare glass 2961010920 05 DQ96-x Measuring input 4-20 ma with customised scale incl. anti-glare glass and red pointer in glass 2961060920 01 DQ96-c/-xc All measuring inputs, without scale 2961060920 02 DQ96-c/-xc All measuring inputs, with standard scale 2961060920 04 DQ96-c/-xc Direct current measurement with standard scale 2961011420 01 DQ144-x All measuring inputs, without scale 2961011420 02 DQ144-x All measuring inputs, with standard scale 2961011420 03 DQ144-x Direct current measurement with standard scale 2961061420 01 DQ144-c/-xc All measuring inputs, without scale 2961061420 02 DQ144-c/-xc All measuring inputs, with standard scale 2961061420 03 DQ144-c/-xc Direct current measurement with standard scale Order specifications s: Item no. Type Additional options to the standard variant no. Measuring range Scale Option Option Example: Additional options to the standard variant Item no. Type no. Measuring range Scale Option Option 2961060420-02 DQ48-c 02 0 10V DC 0 100% Glass w/red adjustable pointer 2961010920-03 DQ96-x 03 0...40 A 0..40 A IP54 2961010920-02 VDQ96-x 02 0...100V AC 0 100 V Red line at 75 V Anti-glare glass DEIF A/S Page 5 of 12

Quadratic moving iron instruments (EQ) Application: Measurement of AC currents and AC voltages, adjusted for frequency range 16...65 Hz. Calibration for other frequency ranges (see p. 2). The instruments measure true R.M.S. Working range: Ammeters are designed according to EN60051-2 (Item 6.4.1 and 6.4.2) Continuous overload: I N x 1.2 Short duration overload: I N x 5 for 5 sec. I N x 10 for 0.5 sec Valid for -/1 A, -/5 A and direct connections. Scale range: The scale is standard designed with a 2 times overload range (non-standard scale - see p. 2) Scale lengths: EQ48/72/96/144-x: 41/62/92/135 mm Accuracy: Class 1.5 Burdens: Voltmeters: Approx. 1.5...4 VA Ammeters: Approx. 0.5...1.2 VA Housings: Plastic V 100 A 60 120 50 40 20 0 0 EQ96-x (voltmeter) EQ96-x (ammeter) EQ48-x EQ72-x EQ96-x EQ144-x Type Size (mm) Measuring range - V 1) 4) 1) 2) 3) Measuring range - A 48 x 48 72 x 72 96 x 96 144 x 144 40 V... 300 V 40 V... 800 V 40 V... 800 V 40 V... 800 V 1 A... 40 A 1 A... 60 A 1 A... 60 A 1 A... 60 A 1) Standard measuring ranges: 1-1.2-1.5-2 - 2.5-3 - 4-5 - 6-8 and multiples of 10 thereof 2) Safety Cat. III 600 V max. ph-ph voltage according to scheme 3) Higher measuring ranges: For use with external current transformer, -/5 A, -/1 A 4) Higher measuring ranges: For use with external voltage transformer, -/100 V (-/110 V) Exchange of scale, quadratic instruments 1) Press cover at top of instrument as shown. 2) Remove scale by means of a suitable tool (e.g. screwdriver). 3) After exchange of scale: refit cover (press till it snaps into place). Calibration is not needed. Note: Interrupt signal to terminals before exchanging the scale. DEIF A/S Page 6 of 12

Available variants Item no. no. description 2961110420 01 EQ48-x Volt with standard measuring input and standard scale 2961110420 02 EQ48-x Volt for VT or non-standard measuring input and standard scale 2961110420 03 EQ48-x Current /1 A or /5 A CT with standard scale 2961110420 05 EQ48-x Current for /1 A or /5 A CT with customised scale and anti-glare glass + red pointer in glass 2961110420 06 EQ48-x Current direct reading with standard scale 2961110720 01 EQ72-x Volt with standard measuring input and standard scale 2961110720 02 EQ72-x Volt for VT or non-standard measuring input and standard scale 2961110720 03 EQ72-x Current /1 A or /5 A CT with standard scale 2961110720 05 EQ72-x Current for /1 A or /5 A CT with customised scale and anti-glare glass + red pointer in glass 2961110720 06 EQ72-x Current direct reading with standard scale 2961110920 01 EQ96-x Volt with standard measuring input and standard scale 2961110920 02 EQ96-x Volt for VT or non-standard measuring input and standard scale 2961110920 03 EQ96-x Current /1 A or /5 A CT with standard scale 2961110920 05 EQ96-x Current for /1 A or 5 A CT and anti-glare + red pointer in glass 2961110920 06 EQ96-x Current direct reading with standard scale 2961111420 01 EQ144-x Volt with standard measuring input and standard scale 2961111420 02 EQ144-x Volt for VT or non-standard measuring input and standard scale 2961111420 03 EQ144-x Current /1 A or /5 A CT with standard scale 2961111420 05 EQ144-x Current for /1 A or 5 A CT and anti-glare + red pointer in glass 2961111420 06 EQ144-x Current direct reading with standard scale Order specifications s: Item no. Type no. Measuring range Scale Additional options to the standard variant VT primary/secondary Option Option Example: Item no. Type no. Measuring range Scale 2961110420-01 EQ48-x 01 0 400 V 0 400 V Additional options to the standard variant VT primary/secondary Option Option Glass w/red adjustable pointer 2961110920-03 EQ96-x 03 CT 500/5 A 0 500 A (x2) IP54 (Determined Red line at 2961110920-02 EQ96-x 02 by DEIF) 0 12 kv 11 kv/120v AC 10.5 kv Note: When ordering an EQ meter for connection via a voltage transformer (VT), both primary and secondary of the VT must be stated as shown above. DEIF A/S Page 7 of 12

Edgewise moving coil instruments (DPR) Application: Measurement of DC currents and DC voltages Scale: Linear Accuracy: Class 1.5 Burdens: Voltmeters: 1 ma, R i : 1 kω/v Ammeters: 60 mv...0.5 V Housings: Plastic DPR48 DPR72 DPR96 DPR144 Type Size (mm) Measuring range - V 1) 2) 1) 2) Measuring range - A 48 x 24 72 x 36 96 x 48 144 x 72 1 V... 600 V 1 V... 600 V 1 V... 600 V 1 V... 600 V 1) Standard measuring ranges: 1-1.2-1.5-2 - 2.5-3 - 4-5 - 6-8 and multiples of 10 thereof NO LONGER FOR SALE 2) Safety Cat. III 600 V max. ph-ph voltage according to scheme DEIF A/S Page 8 of 12

Available variants Item no. no. description 2961360430 01 DPR48 All measuring inputs with standard scale 2961360730 01 DPR72 All measuring inputs with standard scale 2961360940 01 DPR96 All measuring inputs with standard scale 2961361430 01 DPR144 All measuring inputs with standard scale Order specifications s: Item no. Type Additional options to the standard variant Measuring no. Mounting 1) range Scale Option Option Example: 1) Additional options to the standard variant Item no. Type no. Mounting 1) Measuring range Scale Option Option 2961360940-01 DPR96 01 Horizontal 4 20 ma 0 10 bar Red line at 8.5 bar Horizontal or vertical. NO LONGER FOR SALE DEIF A/S Page 9 of 12

Slim edgewise moving coil instruments (DSM) Application: Measurement of DC currents and DC voltages Scale: Scale lengths: Linear DSM72/96/144: 52/70/95 mm Accuracy: Class 1.5 Burdens: Voltmeters: 1 ma, R i : 1 kω/v Ammeters: 60 mv...0.5 V Housings: Plastic DSM72 DSM96 DSM144 Type Size (mm) Measuring range - V 1) 2) 1) 2) Measuring range - A 72 x 24 96 x 24 144 x 36 60 mv... 600 V 60 mv... 100 V 1) Standard measuring ranges: 1-1.2-1.5-2 - 2.5-3 - 4-5 - 6-8 and multiples of 10 thereof 2) Safety DSM 72: Cat. III 600 V max. ph-ph voltage according to scheme DSM 96: Cat. III 100 V max. ph-ph voltage according to scheme DSM 144: Cat. III 300 V max. ph-ph voltage according to scheme NO LONGER FOR SALE DEIF A/S Page 10 of 12

Available variants Item no. no. description 2961380720 01 DSM72 All measuring inputs with standard scale 2961380920 01 DSM96 All measuring inputs with standard scale 2961381420 01 DSM144 All measuring inputs with standard scale Order specifications s: Item no. Type Additional options to the standard variant Measuring no. Mounting 1) range Scale Option Option Example: 1) Additional options to the standard variant Item no. Type no. Mounting 1) Measuring range Scale Option Option 2961380920-01 DSM96 01 Horizontal 0 1 ma 0 300 A Red line at 250 A Horizontal or vertical. NO LONGER FOR SALE DEIF A/S Page 11 of 12

Dimensional details Quadratic instruments (90 and 240 ) 1) For range 15 40 A = 59 mm 2) Protective power All dimensions in mm Type A C B Panel cut-out Weight (approx.) 90 Moving coil and moving iron instruments Q48-x Q72-x Q96-x Q144-x 48 x 48 72 x 72 96 x 96 144 x 144 240 Moving coil instruments DQ48-xc/c 48 x 48 DQ72-xc/c 72 x 72 DQ96-xc/c 96 x 96 DQ144-xc/c 144 x 144 5.0 5.5 5.5 8.0 5.0 5.5 5.5 8.0 Edgewise moving coil instruments 42.8 x 48.8 66.5 x 66.5 90 x 90 136 x 136 42.8 x 48.8 66.5 x 66.5 90 x 90 136 x 136 45 x 45 +0.3 68 x 68 +0.4 92 x 92 +0.4 138 x 138 +0.5 45 x 45 +0.3 68 x 68 +0.4 92 x 92 +0.4 138 x 138 +0.5 0.090 kg 0.200 kg 0.210 kg 0.350 kg 0.180 kg 0.220 kg 0.250 kg 0.400 kg All dimensions in mm Type A B C DPR48 DPR72 DPR96 DPR144 48 x 24 72 x 36 96 x 48 144 x 72 3 4 4.5 5.5 Slim edgewise instruments 5 5 6.7 8 D + E (max.) 75 99 143 192 E F1 x F2 G Panel cut-out Weight (approx.) 8 9 7 3 45 x 18 66 x 32.5 91 x 43 136 x 66 53 79 104 150 43.2 +0.3 x 22.2 +0.3 68 +0.7 x 33.0 +0.6 92 +0.8 x 45.0 +0.6 138 +1.0 x 68.0 +0.7 0.050 kg 0.100 kg 0.450 kg 0.950 kg All dimensions in mm Type A B C D E F1 x F2 G DSM72 DSM96 DSM144 72 x 24 96 x 24 144 x 36 3.5 x 5 3.5 x 5 4 x 6.5 6 6 7 90 110 164 8 8 9 17 x 65 17 x 89 32 x 137 75 99 147 H (max.) 40 40 40 Panel cut-out 68 +0.7 x 22.2 +0.3 92 +0.8 x 22.2 +0.3 138 +1.0 x 33.0 +0.6 Weight (approx.) 0.080 kg 0.100 kg 0.240 kg DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Due to our continuous development we reserve the right to supply equipment which may vary from the described. Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: deif@deif.com, URL: www.deif.com