SIPS instructions for installation and use

Similar documents
Hubble Optics CDK 17 Collimation Instructions 03/27/2012 Hubble Optics

PlaneWave CDK Telescope Instructions. Setting the spacing and collimation for the CDK14/17/20/24

Howie's Laser Collimator Instructions:

USING THE 2 TELETUBE XLS TM & TELECAT XLS TM ADJUSTABLE SIGHT TUBE

AG Optical Systems. Newtonian Astrograph Manual Version AG Optical Systems

OWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty

The Astronomical League

Lab 10: Lenses & Telescopes

SQ2 User Instructions SQ2 Overview:

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

1503 Follow Spot Yoke, Source Four LED

Step 1 Remove Focus Knob

ECEN 4606, UNDERGRADUATE OPTICS LAB

Physics 2020 Lab 8 Lenses

STEINBERGER TRANSTREM (TYPE 2) TECHNICAL DOCUMENT

INSTALLATION MANUAL PBL-UMP

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

OWNER S MANUAL. But that s just half the story. The fence INCRA Miter Gauge really does work

The only coma-corrector for Newtonian telescopes which does not increase the focal length. An f/4 Newton stays an f/4 Newton! Properties of the MPCC:

Olivier Thizy François Cochard

(6) Plastic Retainers. Passenger/Right. Passenger/Right Support Brackets

7. Michelson Interferometer

model tsa-sa48 Sliding Crosscut Table installation guide

OWNER S MANUAL CONTENTS. The only table saw fence with Automatic Positioning Control TM

Disc Sander Angle Jig Instructions

Hubble Optics Ultra Portable UP 12 Dobsonian instruction manual

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Applications of Optics

AR15 SUPER SLIM AND ULTRA SLIM FREE FLOAT RAIL SYSTEMS

INSPECTION AND CORRECTION OF BELLHOUSING TO CRANKSHAFT ALIGNMENT

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

Installing the Partridge RA Extension on Losmandy G11

O5: Lenses and the refractor telescope

Hubble Optics Ultra Light UL 16 Dobsonian instruction manual

Constable Oak Extension Dining Table

VARIABLE SPEED WOOD LATHE

Eric B. Burgh University of Wisconsin. 1. Scope

Inventory (Figure 2)

Zoom Stereo Microscope NYMCS-360 Instruction Manual

Installing CNC Stepper Motor Mounts On A Sherline Lathe

SPECIFICATIONS. The WM-6XL Long Wm. Malcolm Telescopic Riflescope Instruction Manual WARNING:

The following article is a translation of parts of the original publication of Karl-Ludwig Bath in the german astronomical magazine:

INSTALLATION MANUAL PBC-UMS

RPMSP Series Installation Guide

AG Optical Systems LLC

A socket contact support (supplied separately) must be installed onto the locator assembly.

OPTICS LENSES AND TELESCOPES

Adjusting Backlash on Sherline handwheels

Congratulations! You are now on your way to enriching your life with!

Want to make a travel scope but too lazy to read the whole thing? Read this:

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

FAIRFAX ROUGHING-IN K-12151T=673. UNIT: mm K-12153T K-12156T K-12151T=610 K-12157T K-12161T T01-A -1- INSTALLATION INSTRUCTIONS

Physics 208 Spring 2008 Lab 2: Lenses and the eye

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

Corner Key Doweling Jig Instructions Effective July 2018

Maintenance Information

Customer Notice: Congratulations again on your SawStop purchase, and thank you! -SawStop Tualatin, OR

Q-Zone Hoop-Frame. Assembly Instructions. Copyright July 11, 2018 Grace Company (Reproduction Prohibited) Version 1.8

Removing outter components

Thermostatic Valve Trim

MODEL T27697 & T " & 8" HELICAL CUTTERHEADS INSTALLATION INSTRUCTIONS

MODEL T10815 GRINDING ATTACHMENTS INSTRUCTIONS

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

PLANISHING HAMMER STAND OWNER S MANUAL

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

INSTALLATION MANUAL ELPMBUNI

Adaptive Coronagraphy Using a Digital Micromirror Array

Ceiling Tile Installations Part 1. Sheetrock Installations Part 2. WolfVision Support 2055 Sugarloaf Circle, Suite 125 Duluth, GA 30097

VARIABLE SPEED WOOD LATHE. Model DB900 INSTRUCTION MANUAL

For Barrel Tapers. Installation and Operating Instructions For use with small combination belt & disk sanders. Assembled Taper Tool

FACTORY CAT TOMCAT CORPORATION

TITAN-BIT KEY-CUTTING MACHINE INSTRUCTION MANUAL

MODEL T " SPIRAL CUTTERHEAD INSTALLATION INSTRUCTIONS

Motorized M3 AX7200 Rotary-Style Gasket Cutter Operating Instructions

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Sliding Crosscut Table installation guide

JK Rear Crusher Flares

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

Replacing the build plate clamps

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification.

WILLIS WALL-MOUNT FAUCET INSTALLATION

Exercise 8: Interference and diffraction

Installing CNC Stepper Motor Mounts On A Sherline Mill

INSTALLATION INSTRUCTIONS 3"/4 BENT END SIDEBARS FORD F-150 SUPERCREW PART # DZ /DZ

Geometric Optics. Objective: To study the basics of geometric optics and to observe the function of some simple and compound optical devices.

ULTRAFEED INDUSTRIAL TABLE PACKAGES Set-up Guide for #120931, # & #121091

PACIFIC LASER SYSTEMS. HVL100 Procedures

Gared Pro-S Portable Backstop

LIGHT BEAM ANTENNA MaxRange Antenna Series Assembly Instructions MaxRange Plus Digital / High Definition Television Antennas

Installation Instructions FW8S-STXL / FW8G-STXL Filter Wheel

TP3100(EA) Series TP3123(EA) / TP3126(EA) / TP3129(EA) / TP3132(EA)

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

MODEL T28173/T28174 ROLLER TABLES INSTRUCTIONS

Operation Manual Panel Mounting Gas Pressure Regulators

Transcription:

SIPS instructions for installation and use Introduction Thank you for purchasing the Starlight Integrated Paracorr System (referred to as SIPS hereafter), which incorporates the best focuser on the market a Starlight FeatherTouch focuser with all the benefits of the Paracorr Type 2. The SIPS is the only combination focuser and stationary coma corrector currently on the market. With this finely crafted piece of equipment set up properly, all you have to do is put in a TeleVue eyepiece. After proper installation, whenever an eyepiece is focused (for infinity-corrected vision), it is automatically at the best position for optimal image quality. No tuning is needed - just enjoy the views. How does it work? Placing the SIPS lenses at the proper location during the adjustment step ensures that you will see the best results that the Paracorr Type 2 system is capable of producing, no matter the focal ratio of your telescope, and no matter which TeleVue eyepiece you place in the focuser. (While the Paracorr and SIPS are tailored for and recommend for use with TeleVue eyepieces, it may be used with oculars manufactured by other companies if the positioning of the focal plane allows them to come to focus.) Considerations for eyeglass wearers The SIPS is meant to be used by people with infinity-corrected vision, which means that observers who are strongly near- or far-sighted should use their glasses and long eyerelief eyepieces when observing with the SIPS. Observing with the SIPS without eyeglasses may induce coma because the eyepiece-to-sips position will vary from its coma-corrected position when the observer focuses. NOTE: If you are strongly near- or far-sighted and prefer to observe without corrected vision (without your glasses), choosing a regular Paracorr 2 with a tunable top instead of a SIPS will maintain coma correction independent of focus position. Coma correction The Paracorr Type 2 is the updated version of the popular Paracorr coma corrector. It offers improved performance over the discontinued Type 1 at all focal ratios, especially in the range below F/4. Using the Paracorr 2 with an F/3 mirror makes it perform like an F/12 without a Paracorr - virtually diffraction limited over the full field as noted on the TeleVue website. http://www.televue.com/engine/tv3_page.asp?return=advice&id=103

Other reasons to choose a SIPS a note by Mike Lockwood Personally, I prefer a SIPS (Starlight Integrated Paracorr System) for four reasons, two optical and two mechanical: 1) I don't binoview. The SIPS usually needs to be completely removed for this. However, binoviewers also don't generally agree well with very fast telescopes anyway, so this is not an issue for me. 2) For infinity-corrected vision, the Paracorr 2 in the SIPS is always perfectly "tuned" after the setup procedure is completed. I never have to worry about tuning it, no matter what eyepiece is used. This saves me time while observing. However, I don't wear glasses. If you do, you will want to keep them on so that you are infinity-corrected. 3) The lens group is always exactly centered on the optical axis and is never tilted. The way it is machined ensures this. The tunable top Paracorr 2 unit can tilt slightly in some focusers as the thumbscrews are tightened, slightly degrading images. I have experienced this myself, and it is clearly noticeable under good observing conditions. 4) The SIPS unit has its mass closer to the focuser board, resulting in slightly less flexure of a focuser board. With the tunable top Paracorr, the Paracorr and an eyepiece are extended well above the focuser, increasing flexure of the system and focuser board. When using the SIPS, the focuser has only the eyepiece in the barrel, and this results in less flexure of the focuser. For these reasons, I recommend the SIPS for all visual Newtonian telescopes, and have used it myself down to f/2.8, and even f/2.55 in an experimental instrument. Designing your telescope for use with the SIPS It is simple to design for the SIPS if you are building your own telescope. Refer to Figure 13 at the end of this document this diagram shows where the focal plane would be if the Paracorr was not there - 88mm above the bottom lens. So, for your telescope design, put the focal plane 88mm from the bottom of where the SIPS lens will be. (This value does not change with f/#.) This will let you size the secondary mirror for a given illuminated field. From the diagram, note that the locking ring (the part that has "STARLIGHT INSTRUMENTS, LLC" painted on it), which contacts the top of the mounting plate and locks the rotation of the SIPS unit after it is adjusted, adjusts from 20-40mm from the bottom lens. Let's center it at 30mm for sake of this example, leaving you 10mm of adjustment up or down to tune the SIPS during the initial setup, which should be enough unless the telescope is set up differently than most. That means that we have: 88 mm - 30 mm = 58 mm from the focal plane to the top of the mounting plate.

The mounting plate is 6mm thick, so the focal plane should be: 58 mm + 6 mm = 64 mm from the top of the focuser board. So, that's your rule - set the telescope up to put the focal plane about 64 mm (~2.5") above the top surface of your focuser board, and then install and tune the SIPS as per the SIPS instructions. In case you're wondering how large of a field you should illuminate with the secondary mirror, TeleVue calculated the fully illuminated field for the Paracorr 2, assuming a 60" focal length: f/2.5-14.0 mm f/3.0-22.4 mm f/3.5-26.0 mm f/4.0-27.9 mm f/4.5-29.8 mm f/5.0-31.6 mm So, as you can see, that's large enough for comfortable visual use down to f/2.5, and because our vision is not sensitive to a a smooth falloff in illumination, we probably won't notice that at low powers. I have never actually noticed illumination falloff in my 20 F/3 or my 14.5" F/2.55. Now it's time to install the SIPS. Diagram The parts of the SIPS are labeled in Figure 1. (The eyepiece is not included!) The focuser portion is a standard 1.5"-travel Feather Touch focuser. The focuser can be purchased with the rest of the unit, or you may use your own 1.5"-travel Feather Touch if you already have one. IMPORTANT: The SIPS unit was designed for use with the 1.5"-travel, 2"diameter Feathertouch focuser. Other diameters will not fit. Longer focusers will bottom out, possibly providing insufficient travel. Shorter focusers may also provide insufficient travel. By removing the need to tune the Paracorr, less focuser travel is required to reach focus with all TeleVue eyepieces. The 1.5"-travel model comfortably covers the required focusing range. The focuser portion is mounted on the Paracorr module of the SIPS. It is attached with three setscrews. The Paracorr module sits below it. A locking ring is threaded onto the Paracorr module. Loosening this ring allows the whole assembly to be rotated. This adjusts the height of the whole assembly by threading it into or out of the mounting ring, which sits below the locking ring and inside of the base. The base mounts on your telescope.

Installation Carefully unpack the SIPS unit parts. If you already have a 1.5"-travel Feather Touch focuser mounted on your telescope, detach it from the base by loosening the two setscrews that hold it in place. Either a leveling base or standard base (without leveling screws) may be used with the SIPS. If you do not have a Feather Touch focuser, you will need to purchase and install the focuser and SIPS package. To install the base, accurately center the base over the existing hole and drill mounting holes. Install the base using the provided bolts and nuts (Figure 2). Next, verify that the mounting ring and locking ring are both threaded onto the SIPS Unit. Install this assembly in the base by tightening the two setscrews on opposite sides of the base (Figures 3, 4) using the provided hex wrench. Install the Feather Touch focuser on top of the SIPS Unit by tightening the three setscrews around the top of the unit (Figures 5, 6). But first rack-out the drawtube! This completes the assembly of the SIPS unit. If you have purchased a leveling base, then after the focuser is installed, align the focuser using the adjustment screws. Assemble your telescope if you have not already done so. Collimation To collimate your telescope, you must remove the Paracorr lens group. We recommend pointing your telescope near or at the horizon before removing the lens group. (This will reduce the chance of dropping it onto the ground should you lose your grip on it.) Reach inside the secondary cage and grasp the knurled bottom of the Paracorr lens group. Carefully unscrew it (counterclockwise). You will feel gentle resistance from an O-ring that provides friction - this reduces the chance of the lens group becoming loose or falling out due to vibration during transport. After a few turns, the lens group will disengage from the threads and it can then be pulled out carefully into the secondary cage. (See Figure 12.) Carefully set it aside where it will be safe and clean. Perform your collimation procedure as normal with your laser, autocollimator, or other collimation tool(s). To replace the lens group, carefully insert it back into the bottom of the SIPS and turn it clockwise until it stops. Do not over-tighten it.

Adjustment Now the Paracorr lens group must be positioned the proper distance from your primary mirror. The SIPS may be used before this step is completed, but the best performance will only be obtained after positioning is done. If there is no tape present, place two pieces of frosted tape (Scotch Magic Tape) across the top of the positioning aid (plastic cylinder). This is shown in Figure 7. Under the night sky, point the telescope at the moon, a bright planet, or a bright star. Using an eyepiece, center the object in the field of view. If your telescope has tracking, engage the drive so that the object stays centered in the field of view. If it does not have tracking, you will need to move the telescope every so often to keep it in the field of view. With the object roughly centered, remove the eyepiece, and set it aside where it will be safe. Slide the positioning aid all the way down into the focuser barrel (Figure 8). It will bottom out when it touches the top of the Paracorr lens group. This places the tape at a particular distance from the lenses. Tighten the thumbscrews on the focuser to hold the positioning aid in place. IMPORTANT: Verify that the focuser is racked all the way in, that is, it will go no farther down. The top of the barrel will be even with the top of the focuser housing. Loosen the locking nut by turning it counterclockwise (Figure 9). The entire SIPS assembly may now be turned (Figure 10). Turning it counterclockwise will raise the unit, and turning it clockwise will lower it. Adjust the height of the unit so that the bright object is sharply focused on the tape. This means that you should make the image of a bright star or planet as small as possible on the tape. The moon, however, should be focused as sharply as possible. (Using the edge of the moon's disk may be the easiest way to do this.) Figure 11 shows Jupiter focused on the tape. (Figure 11 was a time exposure and the telescope was not tracking, so it appears as a short, thin line rather than a point.) One method that may make adjustment easier is to thread the SIPS all the way into the base until it stops. Use the focuser to find the sharpest focus, and then raise the unit by rotating it counterclockwise until the sharpest focus occurs when the focuser is racked all the way in (down). With the object focused sharply on the tape and the focuser racked all the way in, adjustment is complete. It is important to realize that this procedure sets the distance between the Paracorr lens group and the primary mirror. If the primary mirror moves up or down in its cell due to collimation adjustments that are made over time, the SIPS position should be adjusted

periodically to maintain the proper distance between the Paracorr lens group and the primary mirror. Remove the positioning aid, insert an eyepiece, and enjoy the views! Usage and Accessories The SIPS should always be used when using an eyepiece, or you will likely not be able to reach focus. Take your time and use care when removing or reinstalling the SIPS lenses in the dark. Do not force the lens group back into place if the group does not easily screw into place, stop and inspect the threads and clean if necessary. You may wish to consider removing the SIPS while transporting the telescope. It is possible that very rough roads may cause the lens group to unscrew from the housing. Over time the SIPS lenses and other mechanical parts may become dirty. Please refer to TeleVue's instructions for cleaning the lenses. The mechanical parts, including the threads in the SIPS body and on the lens group, can be cleaned with a soft, damp cloth or cotton swab. Keeping the threads clean will ensure that the threads do not become damaged. Various accessories, such as cameras, binoviewers, etc., may be used so long as they do not come into contact with the Paracorr lens group. Be careful when inserting these accessories into the focuser barrel if you have not previously verified that they do not contact the lenses. (Maximum safe depth below the top of the focuser body is 1-3/4.) To use other accessories that reach more than 1-3/4 into the barrel or require more intravel of the focuser, the SIPS may be removed. Detach the focuser from the SIPS, and remove SIPS from the base without loosening the locking ring or mounting ring (thus ensuring that it will be positioned properly when it is reinstalled. A piece of tape may be used to keep the locking ring from rotating). The focuser may then be mounted directly on the base. To reinstall SIPS, reverse the process described above. Final Notes For information on cleaning of the Paracorr lenses go to the link below, or contact TeleVue directly. http://www.televue.com/engine/tv3_page.asp?return=advice&id=103 Credits: Mike Lockwood (http://www.loptics.com) for his time and effort in the production of this manual.

Figure 13 SIPS diagram with dimensions