TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Similar documents
Doc. EA Model Number:

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

MB120S 120W Single Output Medical Series

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

C B. Models. Models 2MOPP

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

50W Constant Current (700mA) Dimming LED Driver

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

TB65 65W Single Output Test and Measurement/Industrial Series

HEC-45LTN-45PFAS Rev A

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LB115S 115W Single Output

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

TE60 60W Single Output External Power Test & Measurement/Industrial Series

HEC-100RTA-48QSCA Rev A1.0

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

TE90 90W Single Output External Power Test & Measurement/Industrial Series

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

TE40 40W Single Output External Power Test & Measurement/Industrial Series

HEC-40LTN-XXPSCA Rev A

LFWLP W 12V 15.00A 25.00A 92%

Typical Efficiency (2) Max. Output Power. 24 Vdc 90 ~ 305 Vac 0~1080mA 26 W 84% EUV-026S024PS(3)

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

HEC-30/35LTA-33TDAA Rev A

Product Specification sheet

HEC-35LTA-XXTSAA Rev A

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

IEC/EN/UL60950 & CE certified, EN55032 Class B

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

HEC-70LCN-350TDAF Rev B

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

PDAM500 Series 500W Power Supply

75W Constant Current (700mA) LED Driver

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

General. Environmental. EMC & Safety

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

DA45C USB-PD. Product Descriptions. 45 Watts

TE W Single Output External Power Test & Measurement/Industrial Series

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

Load (2) Single or Dual

VOF XX - XXX - X

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Load (2) Single or Dual

Max. Output Power. Efficiency (1) 110Vac 220Vac

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Max. Output Power. Typical Efficiency (2) 12 Vdc 90 ~ 305 Vac 0~12.5 A 150 W 92% EUV-150S012ST

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

Max. Output Power. Typical Efficiency (2) 12 Vdc 90 ~ 305 Vac 0~22.9 A 275 W 91.5% EUV-300S012ST

Output Voltage* (nom.)(adjustable)

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Output Voltage Range ma ma 700 ma 176~305 Vac 160~357 Vdc 250W 93% 0.98 EBD-255S105DV

Max. Output Power. Efficiency (1) 110Vac 220Vac

CB Scheme UL508 UL ATEX II3G

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Environmental. Electrical Specifications at 25 O C TYPE HL. Output Constant Current. Output Voltage Range

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Max. Output Power. Typical Efficiency (1) 12 Vdc 90 ~ 305 Vac 0~8.33 A 100 W 91% EUV-100S012ST

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Output Current Range. Max. Output Power. 12 Vdc 90 ~ 305 Vac 10.8~13.2V 0~2900mA 35 W 82% EUV-035S012ST(3)

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Output Current 1.2VDC 1.5VDC 1.5VDC 1.2VDC 1.5VDC 1.5VDC 0.65VDC. Vout=3.6VDC 180µA. Vout=1.8VDC, use E-cap 330µF Vout=3.3VDC and 3.6VDC.

For more information, please visit the product page. output. output current max (A)

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Transcription:

065APS18 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (<0.1mA Normal &,0.3mA single fault) Over-Voltage/Load/Temperature & Short Circuit protections 2.5 Million Hours MTBF 2 x MOPP (means of patient protection) 3 years warranty Safety Standards General Description CB Certified for worldwide use Model Number: MDS-065APS18 B Unit Weight: 130 grams (4.6 Ounces) Dimensions (W x L x H): 50.8x101.6x30.0 mm 2.0x4.0x1.2 in The MDS series of embedded power supply come with universal AC input at 90Vac to 264Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 x MOPP. The MDS series is certified for EMC standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55022 for Information Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used. The MDS series of embedded power supply come with both medical and ITE safety approvals including UL/cUL/CQC/CE and CB certification and are fully compliant with RoHS Directive 2011/65/EU for environmental protection. Model Information Medical AC-DC Open Frame Model Number Input Voltage Range Output Voltage Output Current MDS-065APS18 B 90-264Vac 18Vdc 3.61A Model Numbering MDS - 065 APS 18 B Delta Medical power Supply Max wattage in the product series. Maybe lower at some voltage. 065 65W Family Code Output Voltage Single Output: 18 for 18V 1

Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 90-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current (max) 1.5A @ 100Vac, 0.75A @ 240Vac Efficiency (typ.) 87.7%, Reference Fig.1 Standby Power (max) 0.3W Inrush Current (typ.) 40A @ 115Vac, 80A @ 230Vac Touch Current (max) 0.1mA @ 264Vac NC 1), 0.3mA @ 264Vac SFC 2) 1) NC: normal condition 2) SFC: single fault condition E ffic ienc y ( % ) 100 95 90 85 80 75 70 65 60 115Vac Efficielcy 230Vac Efficielcy 55 50 25% 50% 75% 100% Output load Fig.1 Efficiency versus output load Output Ratings / Characteristics Nominal Output Voltage 18Vdc Total regulation ± 1.5% Output Current 3.61A Output Power 65W Output Peak Load 4.98A* Line Regulation (max) ±0.5% Load Regulation (max) ±1% Ripple & Noise (typ.) 20.8mV pk-pk @ Full load, Reference Fig. 2, Start-up Time(max) 3000ms @ 115Vac Hold-up Time(min) 15ms @ 115Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 50-100% load *Output peak can last 8 sec with 10% duty cycle, and the output voltage should meet ±5% voltage regulation at normal input voltage 2

(a) 115V Ripple & Noise measurement circuit Fig. 2 Ripple & Noise example, 20MHz BW (b) 230V PSU 5cm 0.47uF Ceramic 10uF Electrolytic Load Scope Test Fixture Mechanical Dimensions(W x L x H) Weight (typ.) Terminal Environment Surrounding Air Temperature Power De-rating Operating Humidity Operating Altitude Shock Test (Non-Operating) Vibration (Operating) Input Output Operating Storage 50.8 x 101.6 x 30.0 mm(2 x 4 x 1.2 in) 130 grams (4.6 Ounces) JST 2P JST 4P -10 C to +70 C -40 C to +85 C -10 C to +50 C 100% load 50 C to 70 C de-rate power by 2.5% / C, See Fig. 3 10-95% RH (Non-Condensing) 3,000 meters (9842.52 feet) 50G, 11ms, 3 shocks for each direction 5-500Hz, 2.09Grms, 20 minute for each three axis 3

Protections Over Voltage (max) Over Load / Over Current Over Temperature Short Circuit Protection Against Shock 150%, Latch Mode 150%~210% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Class I with PE* connection *PE: Protective Earth Reliability Data MTBF (typ.) 2.5 Million Hours based on Telecordia SR-332 Safety Standards / Directives Medical Safety ITE Safety IEC60601-1: (Ed.3,2005), EN60601-1:2006, CAN/CSA- C22.2 No. 60601-1:08, ANSI/AAMI ES60601-1: (Ed.3,2005) IEC 60601-1 Edition 3.1 (2012), EN60601-1 (2006) + A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14, ANSI/AAMI ES60601-1:2005/(R)2012 IEC60950-1 (Ed.2,2005), GB4943.1-2011, GB9254-2008, GB17625.1-2003 CE MDD Directive 93/42/EEC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 4000 Vac Input to Ground 1500 Vac Output to Ground 500 Vac 4

EMC (Compliant with IEC 60601-1-2 4th Ed. Requirements) EMC / Emissions EN55011/EN55022,FCC Title 47:Class B Harmonic Current Emissions IEC61000-3-2 Meet Class A limit Immunity to Voltage Flicker IEC61000-3-3 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A 1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC61000-4-3 Criteria A 1) 80MHz-2700MHz, 10V/m AM modulation 385MHz-5785MHz, 28V/m Pulse mode and other modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A 1) :2kV Surge IEC61000-4-5 Level 3 Criteria A 1) Common Mode 3) : 2kV Differential Mode 4) : 1kV Conducted IEC61000-4-6 Level 2 Criteria A 1) 150kHz-80MHz, 3Vrms, 6Vrms at ISM bands and Amateur radio bands Power Frequency Magnetic Fields IEC61000-4-8 Criteria A 1) Magnetic field strength 30A/m Voltage Dips IEC61000-4-11 Criteria A 1) 0% UT, 0.5 cycle (10ms), 0 o /45 o /90 o /135 o /180 o /225 o /270 o /315 o /360 o 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. 3) Asymmetrical: Common mode (Line to earth) 4) Symmetrical: Differential mode (Line to line) Criteria B 2) 0% UT, 1 cycle (20ms), 0 o Criteria A 1) 70% UT, 25 cycle (500ms), 0 o Criteria B 2) 0% UT, 250 cycle (5000ms), 0 o 5

Block Diagram 6

Dimensions W x L x H: 50.8x101.6x30 mm Notes Dimensions are in mm For Open Frame type: There are 4 normal mounting holes. To ensure EMC performance, all mounting holes shall be connected to metal case. 7

Power De-rating Output Power 100% 50% 0% -10 C 50 C 70 C Ambient Temperature Fig. 3 Functions Start-up Time The time required for the output voltage (Vo) to reach 90% of its set value, after the input AC voltage is applied. Rise Time The time required for the output voltage (Vo) to change from 10% to 90% of its steady state value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time 8

Dynamic Response The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load change from 50 to 100% of its rated current. 100% Load Overload & Over current Protections The power supply s Overload (OLP) and Over current (OCP) Protections will be activated when output current is between 150% and 210% of I O (Max load). Upon such an occurrence, V O will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated. and the power supply will go into Hiccup mode (Auto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and I O is back within the specified limit. 50% Load 50ms 50ms 50ms 50ms T (sec) Inrush Current Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Additionally, if the I O is <115% but >100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into hiccup mode until the fault is removed; and, the input voltage is removed, then reapplied. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into hiccup mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. Overvoltage Protection The power supply s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under Protections. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. Short Circuit Protection The power supply s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in Hiccup mode, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 9

Certificate. All Delta Medical Power products conform to the European directive 2011/65/EU. RoHS is the abbreviation for Restriction of the use of certain hazardous substances. Delta has been certified as meeting the requirement of ISO 13485: 2003 and EN ISO 13485:2012 for the design and manufacture of switching power supply and adaptor for medical device. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC60950 and IEC60065. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601 10