ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Similar documents
CXP/CFP 100G MPO Cable Assembly

Multi Fiber Cable Assemblies

FIBER OPTIC CABLE ASSEMBLIES

Multi Fiber Cable Assemblies

Hybrid Cable Assemblies

Industrial Automation

features and benefits

MULTI-FIBER ENGINEERING EXCELLENCE

Single-Armored Cables, Fibers

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Ø560*336mm 4.25 kg 2100 ± 105m

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Parallel Fiber Application Note Introduction to types and uses of parallel multi-mode ribbon cable in optical fiber data transmission.

Ø 1250 * 688 mm 93 kg ± 105m

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

Fixed Attenuators. Features and Benefits. Standards

Multi-fiber testing for 40G Ethernet

Fibre Optic Indoor/Outdoor Cable

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

LazrSPEED WideBand OM5 Solution Global Communication

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

Z EE E E Z E Z Z Z Z Z

Table of Contents. Cable Assemblies & Backplane Interconnects. Fiber Optic Products Catalog. Cable Assemblies &

Fiber Optic Outside Plant Cables (4-144 Fibers)

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Outdoor, Fig 8 Armored, Multi Tube

FIBER CABLE ASSEMBLIES Termini, Cable, and Connectors

Pluggable Transceiver Modules

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

CONTENTS. Introduction Characteristics Product range Pages

Exhibit A Construction Project Manual and Drawings

Outdoor, CCTV or CCTV, Fig 8 Armored.

Migration to 50/125 µm in the Local Area Network

PRO BEAM Series PRO BEAM expanded beam field deployable interconnect F739

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

Outside Plant All Dielectric

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

FTTH Fiber Optical Cable

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Standard Monotube SAFE

Datasheet Outside Plant Cable

/ On the web: / Telephone: IS-FIBER (800)

This special provision is for the installation and testing of the following equipment:

Optical Systems Contents

C O N N E C T I O N S S C H E D U L E

Cabling, FP PRO-series

FEATURED PRODUCTS SECTION 1COMMSCOPE

Tru products are now under the Tru-Win brand from Winchester Interconnect.

FiberHome Fiber Products

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

40GBASE-SR4 & URM-Infrastructure. Verification with BER-T and OTDR. White Paper

Understanding Fiber Optics and Local Area Networks Products, Services, and Support

Table of Contents. Cleaning Accessories Adapter Cleaners Cletop Ferrule Cleaner MPO Cleaner Connector/Adapter Cleaning Kit...

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

Cable Assemblies.qxd 9/17/01 9:48 PM Page 1 Cable Assemblies

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

A3422 XMTDR. Digital Return Optical Transmitter Module. Features

Type QG-G50-2C- M-BU

4 Channel Contact Closure DIN Fiber Link System

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

WIREMOLD Access 5000 Series Raceway

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Fiber Optic Principles. Oct-09 1

GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

CATEGORY 5E MULTIPAIR WIRE

Passive WDM Networking

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Installation Instructions

TIA FO Task Group on Modal Dependence of Bandwidth. 7/99 Status Update

Optical Passives and Accessories

400G-BD4.2 Multimode Fiber 8x50Gbps Technical Specifications

M-FP ISOLATOR PIGTAILS

User Manual. Installation Transmit Receive Module SFP/XFP

Cable and Port Specifications

Faster. Easier. Better.

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Measurement Considerations for Corning ClearCurve LBL and ZBL Optical Fiber

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

Presentation Overview

Instalaciones de fibra óptica en entornos de centros de datos y campus para suportar 40, 100g y más

DC to 12-GHz Amplified Photoreceivers Models 1544-B, 1554-B, & 1580-B

Analog Signal DIN Fiber Link System

INDUSTRIAL ETHERNET CABLING SOLUTIONS. Control. Monitor. Process.

LASER DIODE SOURCE FIBER OPTIC (SINGLE OR MULTI-WAVELENGTH)

600G2 Internal Sliding Adapter Panel Shelf Instructions

WIREMOLD AL7450 Series Isoduct Aluminum Raceway

Technical Specifications

Tru products are now under the Tru-Win brand from Winchester Interconnect.

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Tips and Adapters 2013 Edition

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

10GBASE-S Technical Feasibility

Wavelength Selective Switch (WSS) 1x9

Transcription:

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND designed to be better.

a streamlined approach to network design THE ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND TRUNK CABLES With current high bit rate transmission, advanced applications truly test the limits of optical cable design and installation. Legrand uses quality engineering in each Ortronics trunk cable to ensure performance, reliability and a successful installation. Ortronics pre-terminated trunk cables offer a streamlined approach to network design by reducing the number of individual components in the structured cabling system. The trunk cables route information to the main distribution area (MDA) and zone distribution areas and can support advanced applications making them ideally suited to private network backbone environments. Ortronics trunk cables are fully configurable and available with a variety of cable and connector combinations, including connector type, breakout configurations and jacket material. Each trunk can have multiple connectors of different types and a choice of cable construction in between. Trunk cables are available with today s required fiber types with MTP, LC and SC connectors. The resulting product has a simple design, provides unsurpassed optical performance and is less expensive to install than a multi-component system. RECOMMENDED APPLICATIONS Data Centers Storage Area Networks (SAN) Local Area Network (LAN) FEATURES AND BENEFITS Pre-terminated cable assembly cuts out costly field-termination time, reducing installation costs and eliminating cable and connector scrap Factory testing guarantees fieldinstalled optical performance The easy to configure, wide variety of cable and connector options allow for greater flexibility in network configuration The pre-terminated design facilitates moves, adds and changes Simplicity is part of the design: the labels are right at the boot, no more tracing the cable to find the label

PERFORMANCE SPECIFICATIONS 10G OM3 10G OM4 40/100 OM3 40/100 OM4 0 100 200 300 400 500 600 Distance (meters) MULTIMODE FIBER TYPES AND STANDARDS Attenuation (4) Typical Cabled Maximum (db/km) Overfilled Launch (OFL) Bandwidth (MHz-km) Effective Modal Bandwidth (EMB) 850 nm 1300 nm 850 nm 1300 nm 850 nm OM3 3.5 1.5 1500 500 2000 OM4 3.5 1.5 3500 500 4700 WHY USE ORTRONICS TRUNK CABLES? PERFORMANCE Ortronics trunk cables are suitable for the most advanced applications such as 16 Gb/s Fibre Channel (16GFC), 10/40/100 Gb/s Ethernet and Fibre Channel over Ethernet (FCoE). RELIABILITY Robust cable assemblies, a rapid, consistent and timely delivery system, the most advanced optical fiber and an unparalleled fiber termination process produce the best product for any installation. SIMPLICITY The Ortronics trunk cable offering combines expert fiber optic design with Ortronics electronically configured ordering process and rapid delivery to meet the demanding needs of today s structured cabling users. EASE OF INSTALLATION Ortronics delivers trunk cables on triple flange deployment reels which offer access to all terminations and enable confirmation testing prior to installation, facilitating on-site cable deployment.

TRUNK CABLE PART MATRIX EXAMPLE PART NUMBER: [TADPLKFZAZAXXXM] T A B C D E F G Polarity A = Type A MTP to MTP B = Type B MTP to MTP C = Type C MTP to MTP L = A-A Fixed Duplex M = A-B Fixed Duplex Z = Polarity Not Fixed Cable Type A = Tight Buffered Distribution C= Tight Buffered Indoor/Outdoor D = Micro Array Data Center Loose Tube E = Indoor/ Outdoor Loose Tube Jacket Material and Armor P = Plenum (OFNP) Color Fiber Count Fiber Type B = Orange F= 12 A = 62.5 (OM1) R = Riser (OFNR) H = Black I= 24 C = 9 (OS1/OS2) Breakout End A B = 250mm (9.8") breakout onto 900um tight buffered fiber C = 250mm (9.8") breakout onto 2mm B = Interlocking AL Armor Plenum I = Yellow K= 48 F = 50 (OM3) D = 250mm (9.8") breakout onto 3mm E = Interlocking AL Armor Riser M = Interlocking AL Armor I/O Cable L = Aqua M= 72 G = 50 (OM4) O= 96 J = 9 (OS2 - ITU G.657.A1) E = 1m (39.4") breakout onto 900um tight buffered fiber F = 1m (39.4") breakout onto 2mm G = 1m (39.4") breakout onto 3mm M = 250mm (9.8") 900um breakout, each subsequent subunit leg, subtract 100mm (3.9") N = 250mm (9.8") breakout onto 2mm, each subsequent subunit P = 250mm (9.8") breakout onto 3mm, each subsequent subunit Q = 1m (39.4") 900um breakout, each subsequent subunit leg, subtract 100mm (3.9") R = 1m (39.4") breakout onto 2mm, each subsequent subunit S = 1m (39.4") breakout onto 3mm furcation tubing, each subsequent subunit leg, subtract 100mm (3.9") Z= none or NA DESIGN CONSIDERATIONS The number of finished trunk cable configurations can be overwhelming due to unique network installations; variable transmission rates and multiple fiber, cable and connector choices. To meet specific requirements, Legrand has simplified the complex process of designing customized trunk cable solutions by creating a simple, but powerful cable configurator. The configurator takes into consideration the application, fiber and connector needs, as well as packaging requirements. It is designed to take into account all the variables of fiber cable assemblies, including validation rules, ensuring selections are correct in every way. These few steps ensure that the pre-terminated trunk cable solution is tailored to the demanding needs of the installation. Legrand sales representatives and customer service personnel will guide you through the design process. High quality design, plus high quality product, rapid response and a convenient ordering process, ensures optimal trunk cable configuration.

Y H Z XXX M Connector End A Breakout End B Connector End B Length (breakout to breakout) and Pulling Eye A = MTP (Female - Unpinned) PC polish B = 250mm (9.8") breakout onto 900um tight buffered fiber A = MTP (Female Unpinned) PC polish XXXM (in Meters) no pulling eye, Connector 1 on main spool B = MTP (Male - Pinned) PC polish C = 250mm (9.8") breakout onto 2mm B = MTP (Male Pinned) PC polish XXXN (in Meters) no pulling eye, Connector 2 on main spool C = LC (Duplex) APC D = 250mm (9.8") breakout onto 3mm C = LC (Duplex) APC XXXQ (in Meters) pulling eye Connector 1, D = LC (Duplex) UPC polish E = 1m (39.4") breakout onto 900um tight buffered fiber D = LC (Duplex) UPC polish XXXP (in Meters) pulling eye Connector 2, E = ST, PC polish F = 1m (39.4") breakout onto 2mm furcation tubing E = ST, PC polish XXXR (in Meters) pulling eye both ends, F = SC, PC polish G = LC, PC polish H = LC (Duplex) PC polish I = MTP (Female - Unpinned) APC J = MTP (Male - Pinned) APC L = SC (Simplex) APC M = LC, APC G = 1m (39.4") breakout onto 3mm furcation tubing M = 250mm (9.8") 900um breakout, each subsequent subunit leg, subtract 100mm (3.9") N = 250mm (9.8") breakout onto 2mm, each subsequent subunit P = 250mm (9.8") breakout onto 3mm, each subsequent subunit Q = 1m (39.4") 900um breakout, each subsequent subunit leg, subtract 100mm (3.9") R = 1m (39.4") breakout onto 2mm furcation tubing, each subsequent subunit leg, subtract 100mm (3.9") S = 1m (39.4") breakout onto 3mm furcation tubing, each subsequent subunit leg, subtract 100mm (3.9") F = SC, PC polish G = LC, PC polish H = LC (Duplex) PC polish I = MTP (Female Unpinned) APC J = MTP (Male Pinned) APC L = SC (Simplex) APC M = LC, APC O = Reconfigurable LC (Duplex) APC Z= none or NA O = Reconfigurable LC (Duplex) APC P = Reconfigurable LC (Duplex) UPC Q = ST, UPC R = SC, UPC S = LC, UPC T = SC (Duplex), PC U = SC (Duplex), APC V = SC (Duplex), UPC P = Reconfigurable LC (Duplex) UPC Q = ST, UPC R = SC, UPC S = LC, UPC T = SC (Duplex), PC U = SC (Duplex), APC V = SC (Duplex), UPC W= Reconfigurable LC (Duplex), PC W= Reconfigurable LC (Duplex), PC XXXS (in Meters) pulling eye both ends, XXXF (in Feet) no pulling eye, Connector 1 on main spool XXXG (in Feet) no pulling eye, Connector 2 on main spool XXXH (in Feet) pulling eye Connector 1, XXXJ (in Feet) pulling eye Connector 2, XXXK (in Feet) pulling eye both ends, XXXL (in Feet) pulling eye both ends, Z = no connector Notes: Not all cable and connector combinations are valid. The validity will be verified during the configurator quotation process. MTP is a registered trademark of US Conec.

2013 Legrand All Rights Reserved rev.04 13 FTCSYS designed to be better. Data Communications 125 Eugene O Neill Drive New London, CT 06320 800.934.5432 www.legrand.us 570 Applewood Crescent Vaughan, Ontario L4K 4B4 905.738.9195 www.legrand.ca Follow Us