DSAE - AAA - B - C - DD - E AAA

Similar documents
VF-nC1 Adjustable Speed Drive Engineering Specification

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

S11 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

DynaDrive INFORMATION MANUAL SDFP(S)

E3 Adjustable Speed Drive Engineering Specification

Industrial motor controller for brushed DC motors 24 VDC

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ACH550 HVAC Drive Submittal

IRT AT-Small. Technical Manual. quality IN MOTION. quality IN MOTION

Manual Overview...1 2

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Industrial motor controller for brushed DC motors 24 VDC

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

Industrial motor controller for brushed DC motors 12 VDC

BLuAC5 Brushless Universal Servo Amplifier

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

PAM & SAM System User s Manual

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

BLuAC5 Brushless Universal Servo Amplifier

BLOCK DIAGRAM OF THE UC3625

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

The new Yaskawa Varispeed G7 Inverter

Type of loads Active load torque: - Passive load torque :-

NX series Constant and variable torque Variable Speed Drives for induction motors

Inverter Drive /Vector Drive Motors & Controls

EC 45 flat with integrated electronics Document ID: en Operating Manual

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

GS1 Parameter Summary Detailed Parameter Listings...4 9

TECHNICAL INFORMATION edition 1.02 FOR TRANSISTOR-FOUR-QUADRANT SERVO-AMPLIFIER SERIES MTR /5-15

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Analog Servo Drive 30A8

Experiment 1. Speed control of a DC motor with an inner current loop

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

DC Motor Speed Control using PID Controllers

Speed Feedback and Current Control in PWM DC Motor Drives

Understanding RC Servos and DC Motors

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

CONTROLS CS-I. MFDC/AC Inverter Weld Control

AxCent Servo Drive A50A100

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

CHAPTER 8 PARAMETER SUMMARY

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number

Options & Accessories

Variateur analogique courant continu série AZ et AZB

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

6.9 Jump frequency - Avoiding frequency resonance

[ 4 ] Using pulse train input (F01 = 12)

FEATURES DESCRIPTION THE OEM ADVANTAGE

XC4e PWM Digital Drive

Variable Speed Brushed DC Motor Drive

BLOCK DIAGRAM OF THE UC3625

Control chain diagrams

PWM SERVO CONTROLLERS SERIES MRM


Servo Amplifier PMA 90 / 180

FAN Pin PFC and PWM Controller Combo. Features. General Description. Block Diagram.

ME 461 Laboratory #5 Characterization and Control of PMDC Motors

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Phoenix DX Clean Power (18 Pulse) AC Drive

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

Options & Accessories

Emotron FDU 2.0 Variable Speed Drive

XC4e PWM Digital Drive

XC4 PWM Digital Drive

General Specifications FECA-TE /2010. Phone: Fax: Web:

PowerFlex 400 Submittal

ElectroCraft CompletePower Plus Universal Servo Drives

DA4303. User Manual DA Q Linear Servo 03 A

Operating Instructions

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

Cable Solutions for Servo and Variable Frequency Drives (VFD)

MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT

Design Characteristics. FlexDrive II. Series

LVA 4-Quadrant Amplifier 5000

SCA-SS User Manual SCA-SS Q PWM Servo 10 A

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

Analog Servo Drive 30A8

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

vacon nx all in one application manual ac drives Phone: Fax: Web: -

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

Current Transducer CTSR 1-P = 1A

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

SCA-SS User Manual SCA-SS Q PWM Servo 06 A

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

( DIGITAL SERVO AMPLIFIER FOR BRUSHLESS MOTOR ) INSTRUCTION AND USER MANUAL

EPOS2 24/2 EPOS2 24/5 DC (390438) EC (380264) DC/EC (390003) DCX (530239) (367676) (360665) (347717) (375711)

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

vacon nx ac drives all in one application manual

Bidirectional PWM DC Motor Drive with Regenerative Braking

Where: (J LM ) is the load inertia referred to the motor shaft. 8.0 CONSIDERATIONS FOR THE CONTROL OF DC MICROMOTORS. 8.

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Transcription:

Pag. 4 GENERALITY The four quadrant converters of the DSAE 150/300 series integrate both the power supply unit and the braking unit and have been realised to exploit the most advanced technology, in particular the final IGBT stage which operates with a PWM switching frequency of 10 KHz. The regulation is realised by the P.W.M. (Pulse Width Modulation) using a particular technology with 2 different signals (instead of the traditionally used single signal) with a phase displacement of 180 for controlling the final power. The combination of these signals allows to obtain a switching cycle of the final power which reduces the current ripple by 50 % combined with all advantages regarding maintenance and life of the brushes and of the motor. The converters of the DSAE 150/300 series are developed for controlling the speed of D.C. motors with permanent magnets both with dynamo tachometer and armature feedback. IDENTIFICATION DATA For the identification or the order of the converters DSAE, use the following code: DSAE - AAA - B - C - DD - E AAA = 150 Power supply from 20 60 Vac 300 Power supply from 60 190 Vac B = M Present in single phase version only C = P Panel version (totally closed) R Rack version (open day) DD = RE Arranged for external recovery resistance E = A Equipped with a card for armature reaction Example DSAE 300 P - RE - A = DSAE power supplied up to 190Vac, panel version, arranged for external recovery resistance, equipped with card for armature reaction.

Pag. 5 OVERALL DIMENSIONS DSAE 150 P / DSAE 300 P 5/10, 7.5/15 DSAE 150 P / DSAE 300 P 10/20, 15/30

Pag. 6 DSAE 150 R / DSAE 300 R 5/10 15/30 DSAE 150 S / DSAE 300 S [ SLIM VERSION ] 48 183 167 120 SCH 59

Pag. 7 Note: Observe a minimum free distance of 10 cm between converter and surrounding components so as not to hinder the ventilation of the converter.

Pag. 8 TECNICAL FEATURES Version DSAE 150 TYPE POWER SUPPLY NOMINAL CURRENT AT 40 C PEAK CURRENT FOR 1.5 sec. OUTPUT VOLTAGE DSAE 150** / 5A 5A 10A DSAE 150** / 7.5A Three-phase 20 60 VAC ± 10% 50-60 Hz. 7.5A 15A 25 80 Vcc DSAE 150** / 10A 10A 20A DSAE 150** / 15A 15A 30A Version DSAE 300 TYPE POWER SUPPLY NOMINAL CURRENT AT 40 C PEAK CURRENT FOR 1.5 sec. OUTPUT VOLTAGE DSAE 300** / 5A 5A 10A DSAE 300** / 7.5A Three-phase 60 190* VAC ± 10% 50-60 Hz. 7.5A 15A 80 250* Vcc DSAE 300** / 10A 10A 20A DSAE 300** / 15A 15A 30A * Upon request we may supply a converter which is suitable to be power supplied at 220Vac. This converter allows to pilot those motors having a rating voltage up to 300 Vdc. ** All version of converter can be supplied also in single phase configuration.

Pag. 9 GENERAL CHARACTERISTICS Supply voltage of the DSAE 150: Supply voltage of the DSAE 150 M: Supply voltage of the DSAE 300: Supply voltage of the DSAE 300 M: Mains frequency: Output voltage: (DSAE 150) Output voltage: (DSAE 300) Speed loop bandwidth: PWM switching frequency: Switching frequency: Velocity input reference: from three-phase autotransformer with a secondary voltage of 20V 60VAC ±10% from single-phase autotransformer with a secondary voltage of 20V 60VAC ±10% from three-phase autotransformer with a secondary voltage of 60V 190VAC ±10% from single-phase autotransformer with a secondary voltage of 60V 190VAC ±10% 50/60 Hz. 25 / 80 Vdc 80 / 250 Vdc > 100 Hz. 10 KHz 20 KHz on motor ±10 VDC (input impedance 100 KΩ) Regulation: q Maximum adjustable speed with a resistance of R88 on regulation card q Adjustment end of speed by trimmer P5 SPEED on regulation card q Compensation of the offset of the speed signal with trimmer P3 OFFSET on regulation card q Acceleration ramp slope adjustable from 0 a 1 sec. with trimmer P1 ACC. on regulation card q Deceleration ramp slope adjustable from 0 a 1 sec. with trimmer P2 DEC. on regulation card q Current limit adjustable with resistance R83 on regulation card q Rating current of the motor and intervention I*T adjustable with resistance R84 and R86 on regulation card q Proportional gain of the speed ring adjustable with trimmer P4 GAIN. Dynamic constants adjustable through R87 and C24

Pag. 10 Function: q Diagnostics on DISPLAY q Torque programming from the outside by signal from 0 to +10VDC trough closing of the welding point S2 on regulation card q Possibility to connect an external recovery resistance if required (the operation can be made, during the assembly phase, in our firm only) q Possibility to share the CC supply BUS through suitable power terminals. Inner protections: q Against short-circuit between motor terminals q Against mains overvoltage q Against mains undervoltage q Against power overheat q Against excessive energy gain on inner clamp resistance s q Against breakage or failure of dynamo tachometer connections Optional: q Velocity regulation with armature feedback Operation: Temperature: from 0 40 C Humidity: 90% max. without condensation Altitude: 1000 m.

Pag. 11 FUNCTIONAL DIAGRAM