Complimentary Reference Material

Similar documents
Acterna T-BERD Outside Plant Tester (209OSP) Simplifying test procedures with one complete solution

Advanced Test Equipment Rentals ATEC (2832) T-Carrier Analyzer

Advanced Test Equipment Rentals ATEC (2832) T-BERD 209A/211. Dual Results Display. Alarm Indicators.

Advanced Test Equipment Rentals ATEC (2832)

Dynatel 965DSP / 3M Far-End-Device Setup

Sage Instruments 935AT. Test Options Guide

3M Dynatel Far End Device III

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

3M Dynatel Far-End Device (FED II) Applications

Complimentary Reference Material

ProBER 2 2 Mb/s Handheld Test Set. The handheld that takes 2 Mb/s testing beyond convention

TTC INTERCEPTO R 147. Artisan Technology Group - Quality Instrumentation... Guaranteed (888) 88-SOURCE

Complimentary Reference Material

T-BERD /MTS-4000 Multiple Services Test Platform Copper Services Module

HiGain H4D-409-L20 Micro-Doubler Unit Quick Installation Guide

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

Far End Device II Model 1342

1995 Metric CSJ , etc. SPECIAL SPECIFICATION ITEM D-I Muldem (Drop/Insert Multiplexor/Demultiplexor)

2 Mbit/s and Data Analyzer. Reference Manual

G7104A Multimaster Base Station Tester

Application Series. SunSet xdsl: TDR Testing Techniques for DSL Circuits

Westell DS1 Network Interface Unit

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

HST-3000 TDR. What is a TDR? JDSU s HST-3000 TDR. Application Note

GDC 086R Issue 4, 10/17/97. Installation and Operation. Metroplex Flexi-Voice Plus Model MP General DataComm

8800SX Series P25 Phase II Test Option 05

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

TSA 6000 System Features Summary

SECTION GPS WIRELESS CLOCK SYSTEMS

RMV25 / RMV50 RMU25 / RMU45

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

SOLUTIONS FOR AN EVOLVING WORLD RFL DSP Powerline Carrier System

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

High-Speed Voice and Data Link Repeater

Figure FXS Front Panel. Figure FXS Front Panel

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

INSTALLATION AND OPERATING MANUAL

Process Control Calibration Made Easy with Agilent U1401A

LCP03. Transient voltage suppressor for dual voltage SLIC. Features. Applications. Description

User s Manual Listen Microphones

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

Obsolete Document. Dynatel

Part VI: Requirements for ISDN Terminal Equipment

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Appendix C T1 Overview

Loop Current Holding Circuit

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

HANWELL UTILITY DATA SHEET

Copper Lines and High Speed

AN INTRODUCTION TO A NEW MICRO-REFLECTION LOCATION TECHNOLOGY

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Introduction. AM7 Central Office Simulator with option boards

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 1. BATTERIES, MODULAR FLOODED LEAD-ACID 2. BATTERIES, MODULAR VALVE REGULATED LEAD ACID

Basic Transceiver tests with the 8800S

Dynatel 900 Series Subscriber Loop Test Sets

SERIES 5-COMPATIBLE INTELLIGENT 4W ETO CHANNEL UNIT MODEL AUA441C (ISSUE 2) (*CLEI Code: 5SC2XM02AA)

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Advanced Test Equipment Rentals ATEC (2832)

TMX PRODUCT LINE: 4-Channel Multiplexer. CATEGORY: ISDN and T/E Carrier. S/T-Interface DS0, DS1, T1, E1, DS1C, T1C, DS2, T2, E2 FEATURES

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

FM RADIO TRANSMITTER

LAN/Length Cable Tester TCT-2690 Pro

HIGH PERFORMANCE MARINE AUDIO SINISTER SDX 2500 CLASS D MONO BLOCK SUBWOOFER AMPLIFIER OWNER'S MANUAL. wetsounds.com

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

CopperPro Series II. The complete test set for qualifying your local loop for ADSL, VDSL and special services.

Lynx. RoIP Gateway DISPATCH LYNX MOBILE. Optional serial ports provide remote control of radio configuration over the VoIP network.

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

OVEN INDUSTRIES, INC. Model 5C7-362

10/100Base. 100Base-FX Switching Converter. User s Manual

Operating Instructions

30 A AC/DC Current Probe TCP0030A Datasheet

Agilent EPM Series Power Meters

RELAY G10S PILOT S GUIDE B Yamaha Guitar Group, Inc. All rights reserved.

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

MOTOROLA MOTOTRBO CAPACITY PLUS RADIO SYSTEM DESCRIPTION

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

DTR Frequently Asked Questions (FAQ) LEAFLET

HIGH PERFORMANCE MARINE AUDIO HTX SERIES HTX-1, HTX-2, HTX-4, HTX-6 OWNER'S MANUAL. wetsounds.com

Cisco Smart SFP Network Interface Device

Base Station Installation and Maintenance

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

KD-CATHDX. Operating Instructions. HDMI/DVI with Bi-Directional IR / Uni-Directional RS-232 via dual CAT5e/6 Baluns (Tx/Rx)

LCP02-150B1 PROTECTION IC FOR RINGING SLICS TIP GND GND RING A.S.D.

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment solutions, from renting short to long term, buying refurbished and purchasing new. Financing options, such as Financial Rental, and Leasing are also available on application. TMG will assist if you are unsure whether this model will suit your requirements. Call TMG if you need to organise repair and/or calibrate your unit. If you click on the Click-to-Call logo below, you can all us for FREE! TMG Corporate Website TMG Products Website Disclaimer: All trademarks appearing within this PDF are trademarks of their respective owners. Form 080/01

T-BERD 209OSP Outside Plant Testing

The TTC T-BERD 209OSP meets the exclusive testing requirements of the outside plant technician. Combining T1/ISDN/DDS/HDSL BERT, TDR, and DVOM, the is a complete tool for qualifying and troubleshooting digital loops. By adding optional FT1 support, pre-programmed intelligent equipment commands, and HDSL loop qualification, you have the most flexible, all-in-one solution for outside plant testing. FEATURES Full Span Transmitter and Receiver Identify marginal troubles with standard T1 stress patterns at various output levels. Easily access signal and error information. Service-effecting results are automatically displayed in SUMMARY RESULTS category. Introduction Cable Qualification Identify cable impairments such as opens, shorts, bridged taps, load coils, splits, crimps, partial opens, grounds, and resistive shorts. Distance to fault is displayed in feet. Automated Testing Qualify T1 spans at the push of a button with AUTOTEST, automated MULTIPAT and BRIDGTAP stress patterns, and automatic receiver configuration. Repeater Adapter Cable-in once. Complete test access to repeatered spans without the use of several cumbersome cables. The T-BERD 209 OSP is the ideal outside plant test set. Graphical Display Control test access with the push of a button. View graphical TDR response to verify cable impairments. Flash Memory Complete field software upgrade in minutes. Lead Acid Battery Five hours of testing time with lead acid dependability. Rugged Enclosure The rugged, NEMA-4X-compliant design keeps the harsh elements out and the unit working, no matter what the testing conditions.

Options 209OSP-1 DC Measurements Option Ohms Measurements Quickly identify physical impairments, such as opens, shorts, grounds, and one-side faults with automated resistance measurements between tip, ring, and ground. Amps Measurements Immediately detect one-side faults, such as opens and grounds, with an automated current measurement between tip and ring. Volts Measurements Quickly isolate bad repeaters and span powering problems with automated voltage measurements. 209OSP-2 TDR Measurements Option Easy TDR Set Up Simply select the cable type and approximate cable length to configure the TDR for use. Avoid the cumbersome process of determining complex constants, such as pulse width and pulse height. Graphical Display Immediately view the TDR trace on the front panel graphical display. Utilize the built-in zoom feature to identify faults such as splits, load coils, high-resistance opens, and bad splices. Fault Identification Automatically identify and locate opens, shorts, and bridged taps. Distance to fault is displayed in feet. DISTRIBUTION FRAME ADAPTER NIU Quickly isolate T1 span troubles by testing in any direction. T1 PORT ADAPTER Accurately identify and locate line faults using the DC and TDR Measurement Options. T1 PORT

Options The is lightweight, portable, and designed for the way you test. 209OSP-3 Channel Monitor Option Simultaneously monitor ABCD signaling bits of all 24 timeslots. Listen to voice quality and view the data bits of an individual DS0. 209OSP-4 Advanced Stress Patterns Option Stress repeater ALBO circuits with 55 OCTET, T1 DALY, and other long user patterns as recommended by the ANSI T1.403 standard. 209OSP-5 Enhanced ESF Option Decode ESF one-second broadcast PRMs to verify remote, in-service circuit performance. Emulate ANSI T1.403-compatible CSU equipment to verify proper operation during circuit installation and fault isolation. Query performance monitoring NIU equipment and retrieve in-service performance data to verify remote circuit operation. Supports Westell TM equipment.

Options 209OSP-6 Smart Loopback/Command Codes Option Send and receive commands for maintenance switch operation to minimize circuit downtime and query performance data. Supports Teltrend TM and Westell equipment. Utilize intelligent repeater technology to qualify and isolate troubles on outside plant spans. Supports Teltrend, Westell, Wescom TM, XEL TM, and TxPort TM equipment. Utilize intelligent repeater technology to sectionalize span problems. 209OSP-7 Fractional T1 Option Perform bit error rate tests on selected channels to verify transmission quality on contiguous and non-contiguous FT1 bandwidth. Verify VF circuit performance with 404, 1004, 2804, and 2713 Hz tones at various output levels. DSX-1 INTELLIGENT OFFICE DISTRIBUTION FRAME INTELLEGENT LINE INTELLEGENT LINE NIU Use pre-programmed loop codes to sectionalize span problems with the Smart Loopback/ Command Codes options. Rx Tx

209OSP-8 HDSL/ISDN/DDS Measurement Option Perform loss measurements at 28kHz, 40kHz, 48kHz, 82kHz, 163kHz, 196kHz, and 392kHz to assure proper signal level at equipment inputs for HDSL, Basic Rate ISDN, and DDS circuits. Ensure that the local loop does not exceed the CSA requirements for maximum length, including bridged tap length, when provisioning HDSL, Basic Rate ISDN, and DDS circuits. Quickly sectionalize transmission troubles with preprogrammed HTU-C, HTU-R, and doubler loop codes. Supports Pair Gain, Tellabs, Adtran, Westell, and ADC equipment. Options CO CPE Tx/TDR Measure total length of the loop, including bridged taps, to verify that it meets CSA standards. CO CPE Measure signal loss to qualify loop integrity prior to circuit turn-up. Rx Tx Rx Tx

ISDN/DDS Option The ISDN/DDS Analyzer Option will power-up and BERT the entire span. 209OSP-9 ISDN/DDS Analyzer Option Now you can qualify ISDN and DDS pairs during installation avoiding kickbacks and missed dates. With the new ISDN/DDS testing option, your will power-up and BERT the entire span. This will enable you to detect troublesome bridged taps, load coils, wiring problems, and bad repeaters prior to the customer due date. Full Span DDS Transmitter and Receiver Perform BER measurements for 2.4, 4.8, 9.6, 56.0, and 64.0 kb/s service on both primary and secondary channels. Identify marginal troubles with all standard DDS patterns at various output levels. Full Span ISDN U Interface Perform BER measurements for Basic Rate ISDN service. Qualify the local loop for 2B+D service locating troublesome load coils and bridged taps. Span Power Power-up and test repeatered DDS and ISDN loops prior to the installation of the central office equipment. Identify bad repeaters and marginal circuit performance. Pre-Programmed Loop Codes Isolate troubles on DDS and Basic Rate ISDN circuits with pre-programmed repeater, CSU, and NT1 loop codes. CPE Emulation Sectionalize between local loop and CPE troubles with automatic response to CSU and NT1 loop codes. Power-up and qualify ISDN or DDS pairs prior to installing central office equipment. ISDN/DDS ANALYZER Tx/Rx ISDN/DDS ANALYZER Tx/Rx OCU-DP/BRITE CSU/NT1

Verify DLC/DS0 circuits in-service with the DLC/ DS0 Analyzer Option. DLC/DS0 Option 209OSP-96 DLC/DS0 Analyzer Option Full Duplex Channel Monitor Decode signaling bits in both directions on all channels simultaneously. Listen to either or both directions of a VF circuit by dropping the channel(s) to the internal speaker or an external TIMS. Channel Insert Insert either internal test tones or voice and digits from an external butt-set, and control signaling bits without disrupting the remaining active channels. SLC -96 Datalink Monitor Capture major and minor shelf alarms, far-end loopback, line protection switches, and maintenance events in both directions for non-intrusive, in-service verification. SLC-96 Datalink Emulation Verify central office switch and terminal response to alarms, far-end loopbacks, and line protection switches. Execute test pair maintenance requests during system installation and in-service maintenance. Two-Wire VF Input/Output Connect butt-set for DTMF digit transmit, call placement, and talk path for subscriber maintenance and PBX applications. SLC-96 Mode 2 Configuration Timeslot Assignment Results Determine channel and timeslot assignments for systems configured for SLC-96 Mode 2 concentrated applications. DIGITAL SWITCH DSX-1 D SHELF C SHELF B SHELF A SHELF REMOTE TERMINAL Ensure remote terminal operation, verify voice-grade service, and validate signaling transmissions during system qualifications. Rx Tx DLC ANALYZER

Accessories Save time and money with T-BERD Repeater Power Supply and Span Power Multiplexer. T-BERD Repeater Power Supply Power-up a T1 circuit from the distribution frame, and use the to test and qualify circuits prior to the installation and connection of the central office repeater. Select between 60 ma, 100 ma, and 140 ma current selections. Displays span voltage and current for comparison with circuit design. Complies with UL and FCC safety restrictions. Span Power Multiplexer Improve your process and testing efficiency. The Span Power Multiplexer allows you to switch automatically between T1s in the field, and is compliant with UL, FCC, and CSA safety restrictions. Remotely switch power between up to six T1 spans. Use with standard and intelligent line repeaters. Provides a regenerative signal loopback for single-technician applications. T-BERD POWER SUPPLY Power up and qualify up to six spans for faster, more accurate T1 turn-up. T-BERD POWER SUPPLY MULTIPLEXER LIGHTNING PROTECTION BLOCK S

TTC United States California, Colorado, Georgia, Illinois, Maryland, New Jersey, Texas, Washington TTC Subsidiaries Australia, 61-3-9563.4800; Canada, 905-507-4117; France, 33-1-30.48.83.90; Germany, 49-6172.5911-00; Hong Kong, 852-2892-0990; United Kingdom, 44-1189-759696 Behind Successful Networks You ll Find TTC 20400 Observation Drive, Germantown, Maryland 20876 Tel. (800) 638-2049 (301) 353-1550 (MD) FAX (301) 353-0234 www.ttc.com TBOSP - 9/97