APPLICATIONS DATA SHEET. Product: Single Phase AC/DC Power Meter QI-POWER-485

Similar documents
Monitoring Electric Network Via Internet

ENERGY-0-RS. Energy Meter. User manual

ECE 1750 Week ( part (part 1) Rectifiers

NETWORK ANALYZERS Analyzers

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Multimeter 500CVD21 RTU500 series

Energy Management Modular Power Quality Transducer Type PQT-90

EL-AC Electronic Load

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM4-96

Energy Management Modular Power Analyzers Type WM2-96

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

Oscilloscope Function

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power Meter Series PM9

Power Meter Series PM3200 Functions and characteristics

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

METREL Measuring and Regulation Equipment

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Energy Management Modular Smart Power Transducer Type SPT-90

sustainable savings that can be viewed directly on the internet

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

PQM3000R Class A network analyzer according to EN for power quality monitoring

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Energy Management Energy Analyzer Type EM210

DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

UMG 103-CBM. Universal measurement device for DIN rails

GE-AC&DC AC&DC Voltage Source

Technical Data Sheet AMIK 300 / 301

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

ULTRA RAPID POWER QUALITY ANALYZER

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

PA-AB 4Q POWER AMPLIFIER VA Page 1/5

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Energy Management Modular Smart Power Quality Analyzer Type WM3-96

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

PLA 33. Power line analyzer. User and service manual. version 2.4

perfection by simplicity Catalogue

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

Designing High density Power Solutions with GaN Created by: Masoud Beheshti Presented by: Xaver Arbinger

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

SIMPLY TWO INTEGRATED STEREO TUBE AMPLIFIER. Technical characteristics

Integra 1560 and 1580 Digital Transducer Systems

A NEW SINGLE STAGE THREE LEVEL ISOLATED PFC CONVERTER FOR LOW POWER APPLICATIONS

PA-AB 4Q POWER AMPLIFIER

TNM96-ETL Energy Meter & Electrical Powermeter

Programmable AC Power Source Model 9801

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564.

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

Power Quality Analysers

Distribution Level Metering and Visualization Applications

Operating Guide October 2006

ECET Modern Power

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

3 Phase Power Quality Analy er

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Energy Management Energy meters Type EM2-DIN

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter. Key Features

Energy Measurement & Management

MT 560/UMT TRANSDUCER & ANALYZER

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Application and features

Power Electronics Testing

Introduction DIN rail mounted electricity meters

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Applications. diris_581_d_1_gb_cat. Multimeasurement. Currents

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers

Chapter 1. Chapter 2. STS Setup. Chapter 3. Decoder. Chapter 4. ICC Setup. Appendix A - B -

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

Power Quality Monitoring:

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Multimeter 560CVD11 Data sheet

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

TOSHIBA International Corp

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Power of GaN. Enabling designers to create smaller, more efficient and higher-performing AC/DC power supplies

MULTICHANNEL ACQUISITION SYSTEM

Transcription:

APPLICATIONS DATA SHEET Product: Single Phase AC/DC Power Meter QI-POWER-485 Renewable energy: 1. PV String Monitoring: the QI-POWER-485 measures DC current up to 50 A and DC voltage up to 1000 V, with the same device you can measure both Current and Voltage from a Photovoltaic String Box. With RS485 Modbus RTU communication built-in, the data is sent directly to the datalogger without any other hardware or software. Example: 8 strings to monitor, 7x QI-50-V-485 (Current Transformers with RS485) and 1x QI-POWER-485 (Single phase Energy/Power meter) that simultaneously measures the Voltage in parallel to the string.

2. Eolic power Generators & Hydro power Generators: the QI-POWER-485 (Single phase Energy/Power meter) is ideal to be used for measurement with variable frequency from DC to 400 Hz. Eolic and Hydro Power Generators required a Power Meter with this features. 3. Monitoring of Inverter efficiency: when a QI-POWER-485 is connected to the AC side of an inverter, and by using the THD parameter (Total Harmonics Distortion) it will give you feedback on the inverter performance (failure of diodes). The QI-POWER-485 also controls the Supply to the inverter in order to monitor if it work or not. When monitoring the DC current only, it s not possible to realize that.

Home & Building Automations 1. Energy measurement: the QI-POWER-485 simultaneously measures all the most important parameters of a single phase network in Domestic application. Such as Hotel automation, Offices, Banks, and any/all other Building Automation. Using the QI-POWER-485 combined with a GPRS/GSM Modem, with an Wi fi Access point, or with a datalogger with RS485 Modbus RTU, you can monitor all the information by web based application or remote control. The RS485 communication port allows you to control the QI-POWER-485 with any type of Master Modbus device like PC, PLC, HMI, Modem, Wi fi Access Point. The QI-POWER-485 is the smallest single-phase Power meter on the market right now, and for this reason you can integrate it in any existing DB board. Measures : Irms, Vrms, Watt, Var, Va, Vpk, Ipk, Frequency, Cosφ, Energy, THD, MAX and min value of each of them. Input - AC/DC Current up to 300 A AC / 400 A DC - Voltage 800Vac or 1000Vdc OUTPUT- RS485 Modbus RTU

2. Control of distributed load Smart Grid: you can use the QI-POWER-485 for detailed measurement of the consumption of the individual users within the same network. The information, suitably operated by a controller, may be used to handle the loads in an optimal way. 3. LED Power Supply Lighting: the QI-POWER-485 is used to monitor the LED power consumed for public LED lighting systems. The QI-POWER-485 measures simultaneously the THD (Total Harmonics Distortion) that monitors the Led Power Supply to determine whether it works properly or not.

4. Three-phase monitoring with Aron Insertion: for three-phase applications, without neutral, balanced or unbalanced, using only two QI-POWER-485 devices, you can estimate the total power. To do this you need to have a master Modbus device that is capable to calculate the formula below. Green Data Center Energy monitoring: the QI-POWER-485-LV can be used to measure the DC Power consumed of each Server in a Data Center. The LV version allows you to measure with a high degree of accuracy the 48 V DC and the DC Current.

AC/DC Motor Controls Monitoring of several parameters: The QI-POWER-485 measures several parameters like: Cosφ, Frequency, Vpeak, I peak, THD (Total Harmonics Distortion), Active, Reactive, and Apparent Power that allows you to monitor the most important values of an Electric Motor. The QI-POWER-485 is also suitable for DC Brushless motors. Railway monitoring: the QI-POWER-485 is suitable for single phase monitoring on Railways. Ideal for rail applications required to work at 16 2/3 Hz, to monitor the electric traction (typical of German, Austrian and Switzerland). The configuration of the QI-POWER-485 allows you to set the TV and TA ratio using a primary device that covers the High Voltage and Current request for this application.

Telecommunication Radio Base Stations: The QI-POWER-485-LV (Low Voltage) has a Voltage measurement range up to 100 V DC or 80 V AC. The QI-POWER-485-LV allows you to have the correct accuracy to measure the 48 V DC of the rectifier in a Telecommunication shelter together with the DC Current measurement (up to 400 A ) of the battery pack. All in one device. Electrical Car chargers: The QI-POWER-485-300 can be used to monitor the charging of Electrical cars. Also for the new FAST CHARGERS because the device allows you to measure both the 330 A DC and 550 V DC together and gives you all the information by RS485 Modbus RTU.