Eltec Models and Long Range Passive Infrared Thermal Telescopes

Similar documents
4-20mA, 0-10V and general process measuring bargraph displays

Microwave outdoor intrusion detection sensor

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Contents. Volume 8 Sensing Solutions CA E February

Built-in Amplifier Photoelectric Sensor

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Long Range Metal Body Sensor

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

Photoelectric Sensors XUV Sensors with Separate Optical Heads

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

LX Series Part-Sensing Light Screen

INTREPID Model 336 Digital Microwave Link

Digital flow transmitter for continuous flow measurement

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

Distance-setting Photoelectric Sensor

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

LED Displacement Sensor

PNP. 5 to 800 mm sensor to reflector distance on BRT-60x40C NPN

Digital flow ELEMENT transmitter for continuous flow measurement

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER

Model LS 250 Loop Scanner Operator s Manual. Version

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals.

M-0418 REV:0

onlinecomponents.com

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

Distance-setting Photoelectric Sensor

MRW 50, MRW 100, MRW 200. External Protection Barrier. Quick Installation Guide

Digital flow ELEMENT transmitter for continuous flow measurement

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Non-Submersible Industrial Pressure Transducer

ph or ORP Transmitter

VLS 7 (EN 54) # Designed and engineered in the U.K.

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Submersible pressure sensor For oils and fuels Model LF-1

Built-in Amplifier Photoelectric Sensor

MULTI-BEAM LS10 Light Screen System

General-Purpose Photoelectric Sensors with Self-Contained Amplifier

General-Purpose Photoelectric Sensor

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Long Range Metal Body Sensor

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

VLS 15 (EN 54) # Designed and engineered in the U.K.

Load Cell Accessories and Services

Signal Conditioning Amplifier

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

FC Series Signal Conditioners

High Power Outdoor. GaN Solid State Power Amplifiers

Southwest Microwave, Inc S. McKemy Street Tempe, Arizona USA (480) Fax (480) Product Specifications

Thru-beam Sensors. Model SM800 Series. Ideal for small object detection

WORLD-BEAM QS18AF Sensor with Background Suppression

Low Profile. 3 Year Warranty

Signet Flow Transmitter

Level Lance Model 5100

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

MLV40 Series Miniature Sensors

Project Documentation UMRR Automotive Type 146 Data Sheet

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

W 250: Compact photoelectric switch series for a broad range of applications

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

poly-planar ME-51 Subwoofer Amplifier Waterproof Marine Audio

Universal Voltage Cabled Photoelectric E3JK

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

DIGITAL DIRECTION SENSING MOTION DETECTOR MANUAL

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

U-GAGE Q45U Long-Range Ultrasonic Sensors

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

W 150: Miniature photoelectric switch series with completely integrated electronics

VLS 30. # Designed and engineered in the U.K.

+GF+ SIGNET Temperature Transmitter Instructions

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Customized HP100 Sensors. HP300 Series. Customized to solve difficult application problems

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Local Model. Remote Model FPD1000-A. and FPD1000-TX 4-20 ma Transmitter Local and Remote Models

luxcontrol lighting control system DALI sensors basicdim RCL DBC Control module for combination with ambient light sensor, switch and presence sensor

MP Series Radar Transmitter Installation & Operation Manual

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

High Power Outdoor. GaAs Solid State Power Amplifiers

Parallel Beam Linear Sensor

Submersible pressure sensor For water and wastewater Model LW-1

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

P700WLS IoProx Receiver

Signet 9950 Dual Channel Transmitter

R55 Color Mark Sensor

02/11/2015

W27-3: The all-rounder: robust, powerful, very wide range of applications

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

Portable Passive Intermodulation Test Set

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Transcription:

Eltec Models 862-61 and 862-71 Long Range Passive Infrared Thermal Telescopes Please Note: For new applications, Eltec recommends the 864 Series which are low power and hermetically sealed. HOWEVER, Eltec will continue supplying the 862 Series for replacement, for use with present systems, for use in the expansion of present systems and where it is approved and required. DESCRIPTION These telescopes are specifically designed for use as a component in a total security system for long range detection of people and vehicles. Eltec s passive infrared thermal telescopes have been deployed worldwide for over two decades in security systems for industrial, governmental and military installations. The rugged, splashproof construction of these telescopes makes them ideal for outdoor applications. The use of state-of-the-art detector technology, advanced signal processing and precision optics optimizes the discrimination of moving targets from other events. This technology is an exciting alternative to microwave or active infrared links and it is also ideal in critical applications where dual technologies are desired. The simple installation process, and the variety of options available, make these telescopes well suited for a number of applications, some of which include detection of personnel, vehicles, boats, airplanes, fires, explosions, etc. The telescopes can be used in both fixed and temporary installations to monitor events at long distances. ADAPTIVE THRESHOLD DETECTION (ATD) The electronic circuit includes adaptive threshold detection which automatically reduces the system sensitivity when background noise increases due to environmental sources such as grass, branches or bushes moving in the wind or warm air turbulences. This special feature is a key factor for the system s low false alarm rate. The adaptive threshold detection can be disabled if required (walk testing, range measurement, special applications) by closing the wire link switch on the PC board (or by switching to the "ON" position). INTERNAL HEATING All telescopes are equipped as a standard feature with a regulated heating system at the backside of the mirror to avoid clouding of the reflective surface in cold weather. Heating supply is independent from the electronics supply and accepts DC or AC power. It may be powered by AC or DC so long as its specifications are not exceeded. In most cases, it can be connected across the normal DC supply. If an AC supply is used for the heater, do not run in the same cable as the DC supply for the electronics. If low power is required as in temporary or mobile surveillance applications the telescope can be operated without heating. Power requirement for the heating depends on the temperature and can typically reach 1W. It is strongly recommended that the heater be connected, as sensitivity may be reduced and internal damage from condensation may occur if unit is not heated. Such damage will not be covered by warranty.

FIELD OF VIEW - - Curtain Coverage (Model 862-71) Model 862-71 has optics designed for perimeter protection. The field of view consists of two distinct segments with opposed polarity. The horizontal field of view coverage can be seen in Fig 1.1. This model also has downward vertical coverage (curtain coverage) from the main axis (Fig 1.2). On the Model 862-71, the point where the vertical direction curtain coverage begins will vary depending upon how the telescope is aimed. The differences in where the start of the curtain coverage begins (based on grounding the telescope or aiming straight ahead) can be seen in Table 1 and Figs 1.3 and 1.4. Figure 1.1 Figure 1.2 27 o Height Figure 1.3 - Vertical field-of-view (grounded) 27 o 1 o Axis Height Figure 1.4 - Vertical field-of-view (aimed straight ahead) Note: Data is calculated and subject to variations in environmental changes 862-61/71 - Page 2

FIELD OF VIEW - - Narrow Coverage (Model 862-61) The Model 862-61 (Narrow Field of View) is ideally suited for observation of a defined spot from a distance. Fig 1.5 shows the narrow field of view coverage. The unit is often used to monitor a gate or trap-zone at a distance and mounted high when response to activity in the intermediate zone is not desired. The area covered, as a function of distance, is shown in Fig 1.6. If the telescope is used for perimeter protection as an invisible barrier to detect an intrusion, the small cross section of the segments close to the telescope would make it possible to crawl beneath or climb across the segments without being detected, therefore the Model 862-71 is recommended. Telescope model and serial number are located within the back housing and are accessed by unscrewing the back cover. Figure 1.5 Figure 1.6 Figure 1.7 862-61/71 - Page 3

MECHANICAL OUTLINE Optics and electronic circuits are sealed into a rugged, splashproof PVC housing providing exceptional thermal isolation and immunity to thermal shock. RFI protection is provided for use near strong RF sources such as radar and communications transmitters. The back of the telescope can be removed (threaded cover) for access to the terminal block and sensitivity adjustment and is protected by a tamper switch. DIMENSIONS 13.0 in. 3.5 in. CABLE/CONDUIT INSTALLATION The telescope comes with a cable strain relief installed. This strain relief is designed to fit a cable diameter of.125" to.375". The strain relief grip must be tightened securely to the cable in order to prevent moisture intrusion. Also supplied separately is a conduit fitting. If conduit is used in the installation, simply remove the strain relief, replace it with the conduit fitting and fasten securely. Watertight 1/2" conduit must be used. TO PREVENT MOISTURE INTRUSION, MAKE SURE STRAIN RELIEF (OR CONDUIT FITTING) AND BACK COVER ARE SECURELY FASTENED. FAILURE TO DO SO MAY RESULT IN DEGRADATION OF PERFORMANCE AND/OR INTERNAL DAMAGE WHICH MAY NOT BE COVERED UNDER WARRANTY. Conduit Fitting # 945 Strain Relief # 946 CONTROLS AND TERMINAL BLOCK ATD SWITCH SENSITIVITY ADJUST LED TEST POINT Relay shown energized in a non-alarm state. Tamper switch opens when rear cover is removed. 862-61/71 - Page 4

SPECIFICATIONS Mechanical Weight......................... Size........................... Enclosure........................ Colors.......................... 3.0 lbs (1.4 kg) 3.50" (8.89 cm) dia x 12.93" (32.84 cm) long Painted PVC Green, White, Tan, Grey Optical Nominal Range..................... 500 ft (152 m) Horizontal Field of View 862-61....................... 1.6 o 862-71....................... 1.1 o Spectral Response................... 8 to 14 microns Detectors........................ Pyroelectric POD (Parallel Opposed Dual) Lithium Tantalate integrated sensors Electrical Supply Voltage..................... Supply Current Electronics Power................. 10.5 to 28.0 VDC Reverse voltage protected, 100 mv p-p ripple maximum 12 VDC 26 ma 24 VDC 30 ma Heating Power (Typ.).................. TA = +20 o C TA = -10 o C 12 VDC 27 ma 45 ma 24 VDC 20 ma 30 ma Relay Output Ratings................... 3 W, 0.25 A, 28 VDC/20 VAC Transistor........................ Open collector, NPN, 40 VDC, 40 ma Output Impedance (Typ.)............. 25 Ohm @ 25 o C Output Protection................. PTC resistor, current limited Alarm Indication.................... Internal red LED Alarm Hold Time (Typ.)................. 2.0 seconds Sensitivity Adjustment................. Finger adjustable potentiometer, 10 to 100%, (10:1 range) Strain Relief Cable Range................125" to.375" diameter Terminal Block Wire Size................ 24 AWG minimum 18 AWG maximum Environmental Operating Temperature Range............. -40 o C to +70 o C Storage Temperature Range.............. -40 o C to +70 o C Sealing......................... Splashproof (IP64, NEMA 4X) Notes: 1. Any disassembly of this unit will break the seal and void the warranty 2. Foil shielded cable is recommended for RFI protection 862-61/71 - Page 5

ORDERING INFORMATION Desired optics are designated by the choice of first number following the "dash", and color by either the omission or selection of a letter designator after the "1". 862-[optics] [color] Optics 61 = Standard narrow field of view, with anti-reflection coated window (for FOV s, see Figures 1.5, 1.6, & 1.7) 71 = Perimeter version, downward coverage, with anti-reflection coated window (for FOV s, see Figures 1.1, 1.2, 1.3 & 1.4) Colors No letter = Dark grey, textured A = White, shiny, non-textured B = Grey, RAL 7035, non-textured C = Green, olive drab, textured D = Desert tan, non-textured E = Green, flat olive drab, non-textured Other colors available on special request Accessories AO54M1....................... AO55........................ AO56M1....................... Double Mounting Bracket Removable Telescopic Sight Single Mounting Bracket (Split Ring) NOTICE: The information provided herein is believed to be reliable. However, ELTEC assumes no responsibility for inaccuracies or omissions. Due to industry components being incorporated into ELTEC s devices and ELTEC continually striving for product improvement, specifications may change without notice. Silverlight Ltd. Glärnischstrasse 59 CH-8712 Staefa, Switzerland Mail: eltec@silverlight.ch Tel. +41 44 926 4362 Web: www.eltec.ch Online Datasheet Library and Webshop Worldwide Distribution and Support 05/2010