Active: Active probes achieve low input capacitance and high sensitivity by buffering and amplifying the signal close to the point of measurement.

Similar documents
Choosing the right Pico Technology active differential probe

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

PicoSource PG900 Series

400 MHz Passive High-Voltage Probe R&S RT-ZH

PicoSource AS Professional and portable performance at low cost. 8 GHz Agile Synthesizer

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

PicoSource AS GHz Agile Synthesizer. Professional and portable performance at low cost

TA MHz oscilloscope probe TA MHz oscilloscope probe

PKT 512A-RO High Impedance Passive Cable Divider

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

PHV RO High Voltage Passive Probe. Instruction Manual

Keysight N2771B 30 kv High Voltage Probe

USB DrDAQ VERSATILE DATA ACQUISITION

TETRIS User's Guide. High Impedance Active Probe DO177-1

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III


V1.3. TBLC08 50mH AC-LISN TBLC08

Current Transducer CTSR 1-P = 1A

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

TT-SI MHz DIFFERENTIAL PROBE

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

RCTrms Technical Notes

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

Wide-band Models from DC to 100 MHz

Op-Amp Simulation Part II

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

9 Specifications. Specifications NOMINAL CHARACTERISTICS

DC/DC power module 5V / 3A / 15W

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

TT-SI 9001 / TT-SI MHz Active Differential Probes

Tablet Oscilloscope Safety Information

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

VariTrans P D1 TRMS

DC/DC power module 3.3V / 4.5A / 14.8W

1.25Gbps/2.5Gbps, +3V to +5.5V, Low-Noise Transimpedance Preamplifiers for LANs

MD 200A High voltage differential probe

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

WHALETEQ. ESU Neutral Electrodes Impedance Tester. Model: HFPA150. User Manual

79/26 Series III Multimeter

Electrical Measurement Safety. Sponsored By:

DC/DC power module 1.8 V / 5A / 9W

CONNECTING THE PROBE TO THE TEST INSTRUMENT

NE/SA5234 Matched quad high-performance low-voltage operational amplifier

Wide-band Models from DC to 100 MHz

PicoSource PG900 Series USB differential pulse generators

1.General instructions Specifications Description...7

Response time reduction of the ZXCT1009 Current Monitor

LF353 Wide Bandwidth Dual JFET Input Operational Amplifier

IsoVu Optically Isolated DC - 1 GHz Measurement System Offers >120 db CMRR with 2kV Common Mode Range

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

TT-SI MHz Active Differential Probe

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Type CP-S, CP-C & CP-A Switch mode

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

50 μh Line Impedance Stabilisation Network (AC LISN)

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

FEATURES TYPICAL APPLICATIO. LT1194 Video Difference Amplifier DESCRIPTIO APPLICATIO S

CERTIFICATE OF CALIBRATION

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

High Common-Mode Rejection. Differential Line Receiver SSM2141 REV. B FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

LP2902/LP324 Micropower Quad Operational Amplifier

PowerAmp Design. PowerAmp Design PAD112 HIGH VOLTAGE OPERATIONAL AMPLIFIER

PicoScope 4444 See the difference: high-resolution differential USB oscilloscope

Methods for Testing Impulse Noise Tolerance

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

results at the output, disrupting safe, precise measurements.

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

Minimizing Input Filter Requirements In Military Power Supply Designs

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

Model 7000 Low Noise Differential Preamplifier

AC/DC Current Oscilloscope Probe Model SL261

UNISONIC TECHNOLOGIES CO., LTD M4670 Preliminary CMOS IC

High-Speed, Low-Power Dual Operational Amplifier AD826

OBSOLETE. Self-Contained Audio Preamplifier SSM2017 REV. B

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

LM2925 Low Dropout Regulator with Delayed Reset

OPERATING AND MAINTENANCE MANUAL

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

LF412 Low Offset, Low Drift Dual JFET Input Operational Amplifier

Declaration of Conformity to the DeviceNet Specification

High-voltage Differential Probes

Transcription:

Application Note Pico Technology offers many s covering a wide range of voltages, category (CAT) ratings and bandwidths. As the name suggests, these probes have two major features: Active: Active probes achieve low input capacitance and high sensitivity by buffering and amplifying the signal close to the point of measurement. Differential: Differential probes present two non-grounded terminals for connection to the measurement and can thus measure accurately without directly connecting one test node to ground or drawing significant current from either test node. This ability to measure without a low-impedance connection improves safety when measuring high voltages or in the presence of high voltages. Before we look at choosing the correct probe for your application, let s go back a step and explain why you would want to use a differential probe.

1. The problem: signal with unwanted common-mode noise Consider the circuit below. It consists of a signal source (purple) with AC and DC components producing a total output of, which is the signal we wish to measure. In addition, the circuit contains an unwanted voltage source (green) that also has AC and DC components adding up to V CM. V CM stands for common-mode voltage, which means a signal that is added equally to both measurement terminals. As the following diagram shows, viewing the output and ground terminals with a single-ended probe would result in a distorted waveform (V SUM ) on the display. We cannot solve this by connecting the probe ground to the negative terminal of, as that would short-circuit V CM to ground through the oscilloscope and possibly cause a damaging current to flow. We need a probe that can safely detect and ignore V CM. V CM V SUM V CM V SUM Figure 1 - Using a single-ended oscilloscope probe

2. The solution: an The solution, as shown below, is to connect a differential probe across the positive and negative terminals of the signal source. The probe does not measure the common-mode voltage V CM, only the signal of interest, so is what you see on the oscilloscope display. V DIF MAX V DIF V DIF MIN OUTPUT + 7V MAX INTO 50k MIN www.picotech.com OVERRANGE V CM MAX HIGH VOLTAGE DIFFERENTIAL PROBE POWER ATTENUATION RATIO 1/1000 1/100 Linear Range Common Range V SUM + 7000v @ 1/1000 + 7000v + 700v @ 1/100 Peak Working Voltage Transtent Overvoltage V SUM 2500V rms MAX CAT 1 V CM V CM V CM MIN Figure 2 - Using an Differential probes can measure the AC or DC voltage between two points connected to the positive and negative leads with neither of the points being grounded. This enables the probes to take measurements where singleended probes can t, for example at voltages that are much higher than ground potential, and the resulting measurements focus exclusively on the potential difference between the probes. A differential probe must always be operated within its voltage limits. These are explained under Input ranges below. 3. Using the probe for single-ended measurements An often overlooked fact is that the excels at making single-ended measurements when compared to a passive single-ended probe. The rejection of common-mode voltages and low capacitance result in real measurement advantages such as lower noise and lower circuit loading. To make a single-ended measurement, the positive input lead is connected as normal to the signal and the negative input lead is connected to ground.

V DIF MAX V DIF V DIF MIN OUTPUT + 7V MAX INTO 50k www.picotech.com MIN V CM MAX HIGH VOLTAGE DIFFERENTIAL PROBE POWER ATTENUATION RATIO 1/1000 1/100 OVERRANGE Linear Range + 7000v @ 1/1000 + 700v @ 1/100 Common Range + 7000v Peak Working Voltage Transtent Overvoltage 2500V rms MAX CAT 1 4. Bandwidth V CM MIN Figure 3 - Single-ended measurement The quoted bandwidth tells you the maximum rise time of the signal that the instrument or probe can accurately measure. In other words, a 25 MHz oscilloscope or probe will allow frequencies below 25 MHz and reject all above. It will show a 25 MHz sine wave, although with up to 3 db amplitude error. If your signal is a 25 MHz square wave the rise time is much faster, and you will need higher bandwidth in order to measure or display the waveform correctly. The common rule of thumb for selecting a product of the correct bandwidth is: bandwidth (Hz) = 0.35 rise time (s) You must also consider the combined rise time of both the oscilloscope and the probe. The combined rise time t RC of two devices with individual rise times t R1 and t R2 is given by: t RC = t 2 + t 2 R1 R2 This is equivalent to combining the bandwidth of the oscilloscope and the probe. Use the two equations above to find the combined bandwidth of the two devices. High-voltage measurements often contain fast impulses (transients) that have very fast rise times. To measure or display these accurately, the combined bandwidth of the probe and the oscilloscope must be several times higher than the fundamental frequency. Our s and oscilloscopes range in bandwidth from 25 MHz to 800 MHz. Not all are highvoltage instruments so check the specifications carefully.

5. Input ranges There are three main ranges you will see in the specifications: the differential mode range, common-mode range and absolute maximum range. The first two refer to the maximum measurable voltage levels, which depend on the application. The third is the maximum constant non-destructive voltage that can be applied, not including any transient overvoltage that the probe can withstand. Let s look closer: 5.1 Differential-mode range This is the maximum measurable range between the two differential test prods. It is stated as DC+AC Peak and V RMS, because some elements of the probe design are stressed by voltage peaks and others by continuous dissipated power. You must calculate both for every application and ensure that neither exceeds the probe s specification. Active differential probes often have switch-selectable attenuation, with the higher voltage probes having up to 1:100 and 1:1000 times attenuation. Each attenuation setting has its own differential-mode range. The Pico Technology range of s starts from ±15 V DC+AC peak with no switchable attenuation, to ±700 / ±700 DC+AC peak (500 RMS) equipped with switchable attenuation. 5.2 Common-mode range The common-mode range is the maximum voltage that can be measured on either input with respect to ground. Care must be taken when measuring signals with high common-mode voltages because active probes reject the common-mode signal so that it is not displayed on the oscilloscope screen. To check that you are not exceeding the common-mode range, you may need to make separate measurements of each terminal relative to ground using the in single-ended mode or a separate high-voltage single-ended probe. As with differential mode ranges, each attenuation setting has its own common-mode range. When determining the suitability of the probe for your application, take care that neither common-mode nor differential range exceeds the specifications. For a non-cat-rated probe (see below for an explanation of CAT ratings), take care to include any transient voltages in your measurement range. 5.3 Absolute maximum voltage This is the highest constant voltage that the probe can withstand without being damaged. It is not to be confused with the transient protection defined in the CAT rating system. Some probes have very little headroom between the maximum measurable voltage and the absolute maximum voltage, so care must be taken not to overload the probe. Probes without a CAT rating often have no specified transient protection. In this case you must include any transients in the maximum measurable range or risk damage to the probe, other equipment or yourself. 6. Common-mode rejection ratio Having established that the probe has sufficient common-mode range at DC, you must also ensure that any common-mode noise or signal does not feed into your measurements. Common-mode noise can be caused by electromagnetic interference coupled into the input leads, and by noise and surges in the ground of the device under test (DUT) relative to the ground of the oscilloscope. Connecting the grounds of the oscilloscope and the DUT helps to minimize these noise voltages.

Common-mode rejection ratio (CMRR) is a measure of the voltage disturbance on the probe s output relative to the common-mode voltage on the inputs. The higher the CMRR, the better the probe is isolated from commonmode interference. For example, you might know that there is 1 volt of noise on the ground of the DUT. The probe s specification says that CMRR is 100:1. The result is that on the output you could see common-mode noise of up to 10 mv referred to the inputs. CMRR tends to be highest at DC and then decline as the frequency of the common-mode signal increases. 7. Voltage derating The specified absolute maximum voltage for a probe input is valid only at DC and low AC frequencies. Above a certain frequency, the voltage rating starts to drop. This effect, called derating, is generally specified in the form of a graph of voltage against frequency. 10000 Voltage (V RMS) 1000 1000 1000 700 150 100 1M 10M 100M Frequency (Hz) In the example above, the absolute maximum voltage on either of the inputs at low frequencies is 100 RMS. At about 3.3 MHz the voltage starts to decline, until at about 25 MHz it is only 15 RMS. In practice this is seldom a limitation as high frequency and high voltage are rarely found together such signals being more challenging to generate than they are to measure. When using the probe at high frequencies, be sure to consider voltage derating as exceeding the derated voltage could damage the probe. 8. Input resistance The input resistance of the probe is measured between its differential inputs. When you connect the probe to the DUT, you are effectively connecting each test point through a high-value resistor and a small capacitor to ground, thereby creating a path between the two inputs through ground. This will cause some differential current to flow between the two inputs and from each input to ground. However small these currents, they may disturb the circuit under test, so you must consider whether this will significantly affect the accuracy of your measurement. The effect is worse when measuring high-impedance circuits.

9. Safety and the IEC 61010-031 category (CAT) rating system We can t emphasize enough that safe working with electrical test accessories requires competency in the systems being worked on and electrical systems knowledge. You need training before flying a plane, so why would you use electrical test equipment without technical know-how? User safety is paramount when measuring mains voltages. The category rating system has been designed to protect you from the sometimes unpredictable nature of high-energy impulses (transients) resulting from, for example, grid or load faults. The risk to life and safety from lightning strikes, transients and surges depends on the where within the mains supply path you are doing the testing. Categories are related to the amount of energy in an impulse, not just the peak voltage it reaches. Expertise is required to correctly identify the measurement category and to select the appropriately rated instruments and accessories to make the measurement safely. Three measurement categories are defined in IEC 61010-031 (or your equivalent national product safety standard, which may have a different prefix in place of the IEC ), from CAT II up to CAT IV. The higher the rating, the more demanding is the safety requirement for that measurement accessory. In other words, the higher the CAT rating, the more energetic are the transients that the device must withstand and protect the user against. Products without a CAT rating cannot be used on mains installations and so generally have no transient rating. It is important to note that IEC 61010-031 applies only to low-voltage test equipment rated up to 100. 9.1 CAT II For measurements performed on circuits directly connected to outlets of the low-voltage installation. There should be at least three levels of overcurrent protection between these circuits and the supply transformer. Examples: measurements of the mains-supply nodes in household appliances, portable tools and similar equipment. 9.2 CAT III For measurements performed on the distribution part of a building s low-voltage mains installation. There should be at least two levels of overcurrent protection between these points and the supply transformer. Examples: measurements on distribution boards, circuit-breakers, wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, stationary motors with permanent connection to the fixed installation. 9.3 CAT IV For measurements performed at the source of a building s low-voltage installation. There should be at least one level of overcurrent protection between these points and the supply transformer. Examples: electricity meters and measurements on primary overcurrent protection devices and ripple control units. 9.4 Equipment without a rated measurement category (called CAT I on older measurement devices) For measurements performed on circuits not directly connected to a mains supply. Examples: specially protected (internal) circuits derived from a mains supply, telephones, vehicle electrics.

9.5 Working voltages The table below shows that within each category there are predefined working voltages of 5, 10, 15, 30, 60 and 100. The higher the voltage in the given category, the higher the level of protection required. There is no transient protection recommendation for measurements below CAT II. Rated voltage Voltage transients CAT II CAT III CAT IV 5 52 806 V 1.55 kv 10 806 V 1.55 kv 2.55 kv 15 1.55 kv 2.55 kv 4.07 kv 30 2.55 kv 4.07 kv 6.1 kv 60 4.07 kv 6.1 kv 7.8 kv 100 6.1 kv 7.8 kv 12.1 kv Pico Technology does not offer probes suitable for making measurements in CAT IV areas, so for the purposes of choosing a Pico differential probe this article discusses probes only up to CAT III. 9.6 Choosing the right category rating for your application All measurement accessories fit for use on category rated test circuits have a CAT rating marking. Our active differential probes have the category rating and its associated Rated voltage (refer to table above) clearly marked on the probe and in the specification. Take the CAT II 100 rated probe for example: although its transient protection voltage (6.1 kv) is the same as that of a CAT III 60 rated probe, the two probes are not equivalent. Each probe is designed for the CAT rating as labelled and no higher. Some probes may have higher rated test prods than the rating marked on the probe. The TA044, for example, is a CAT I probe with 100 CAT III test prods. This does NOT make it suitable for CAT III use. Think of the 100 CAT III prods as the only thing between you and a potential arc flash, so having higher-rated test prods is just another safety net. The CAT III prods are designed with higher insulation, creepage and clearance distances. The test prods fitted are removable and replaceable. Fused prods are compulsory for making CAT III measurements. We repeat our earlier advice that, if you are in doubt about the suitability and safety of any active differential probe in your application, you must consult a qualified engineer. Pico Technology technical support will be pleased to advise you. 10. Value for money Table 1. IEC-61010-031 categories and their associated transient voltages Differential probes can be expensive. If you need to make multiple differential measurements simultaneously, it usually makes more sense to purchase a differential oscilloscope with its own passive differential probes, rather than several s. The PicoScope 4444 is a high-precision differential oscilloscope, adjustable to 12- or 14-bit resolution. It works with the PicoConnect 441 and 442 probes to make up to four fully differential measurements for a very competitive price.

Product highlights 100 MHz 140 differential oscilloscope probe 100:1/1000:1 TA042 100 MHz 70 differential oscilloscope probe 10:1/100:1 TA043 200 MHz 2 differential oscilloscope probe 10:1 TA045 25 MHz 140 differential oscilloscope probe 20:1/200:1 TA057 25 MHz 70 differential oscilloscope probe 10:1/100:1 TA041 PicoScope 4444 high-resolution differential oscilloscope. 4 channels, 20 MHz bandwidth, 256 MS deep memory. Compatible differential probes: PicoConnect 441 1:1 probe (pictured), PicoConnect 442 100 CAT III probe. For more information, including the latest prices, please visit www.picotech.com/products. United Kingdom global headquarters: Pico Technology James House Colmworth Business Park St. Neots Cambridgeshire PE19 8YP United Kingdom +44 (0) 1480 396 395 +44 (0) 1480 396 296 sales@picotech.com North America regional office: Pico Technology 320 N Glenwood Blvd Tyler Texas 75702 United States +1 800 591 2796 +1 620 272 0981 sales@picotech.com Asia-Pacific regional office: Pico Technology Room 2252, 22/F, Centro 568 Hengfeng Road Zhabei District Shanghai 200070 PR China +86 21 2226-5152 pico.china@picotech.com Errors and omissions excepted. Pico Technology and PicoScope are internationally registered trade marks of Pico Technology Ltd. AR372-3. Copyright 2015 2017 Pico Technology Ltd. All rights reserved. www.picotech.com