WHITE PAPER. Methods for Measuring Display Defects and Mura as Correlated to Human Visual Perception

Similar documents
WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

WHITE PAPER. Guide to CCD-Based Imaging Colorimeters

WHITE PAPER. Five Signs that a Photometry-Based Imaging System is the Right Choice for Your Inspection Application

Understanding Imaging System Specifications for Pixel-Level Measurement of Displays

APPLICATIONS OF HIGH RESOLUTION MEASUREMENT

Automated Solutions for SAE Standard HUD Measurement

IMPROVING AUTOMOTIVE INSPECTION WITH LIGHT & COLOR MEASUREMENT SYSTEMS

DEFINING A SPARKLE MEASUREMENT STANDARD FOR QUALITY CONTROL OF ANTI-GLARE DISPLAYS Presented By Matt Scholz April 3, 2018

MEASURING HEAD-UP DISPLAYS FROM 2D TO AR: SYSTEM BENEFITS & DEMONSTRATION Presented By Matt Scholz November 28, 2018

WHITE PAPER. How to Include Detector Resolution in MTF Calculations. Zemax A Radiant Zemax Company

REPLICATING HUMAN VISION FOR ACCURATE TESTING OF AR/VR DISPLAYS Presented By Eric Eisenberg February 22, 2018

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Novel Approach for LED Luminous Intensity Measurement

Figure 1 HDR image fusion example

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

STEM Spectrum Imaging Tutorial

Imaging Photometer and Colorimeter

Acquisition and representation of images

A Study of Slanted-Edge MTF Stability and Repeatability

Cvision 2. António J. R. Neves João Paulo Silva Cunha. Bernardo Cunha. IEETA / Universidade de Aveiro

Acquisition and representation of images

DIGITAL IMAGE PROCESSING (COM-3371) Week 2 - January 14, 2002

GlassSpection User Guide

Visual Perception of Images

ME 6406 MACHINE VISION. Georgia Institute of Technology

EC-433 Digital Image Processing

Image Extraction using Image Mining Technique

Speed and Image Brightness uniformity of telecentric lenses

WP640 Imaging Colorimeter. Backlit Graphics Panel Analysis

MURA Measurement in VideoWin Introduction

Before you start, make sure that you have a properly calibrated system to obtain high-quality images.

TDI2131 Digital Image Processing

Camera Requirements For Precision Agriculture

CRISATEL High Resolution Multispectral System

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

A simulation tool for evaluating digital camera image quality

Luminescent Background Sources and Corrections

Human Visual System. Prof. George Wolberg Dept. of Computer Science City College of New York

Camera Requirements For Precision Agriculture

Improved sensitivity high-definition interline CCD using the KODAK TRUESENSE Color Filter Pattern

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

3M Transportation Safety Division. Improved Daytime Detection Of Pavement Markings With Machine Vision Cameras

Hartmann Sensor Manual

Automated inspection of microlens arrays

Visibility, Performance and Perception. Cooper Lighting

USE OF HISTOGRAM EQUALIZATION IN IMAGE PROCESSING FOR IMAGE ENHANCEMENT

Exercise questions for Machine vision

Digital Image Processing

Image Measurement of Roller Chain Board Based on CCD Qingmin Liu 1,a, Zhikui Liu 1,b, Qionghong Lei 2,c and Kui Zhang 1,d

A Kalman-Filtering Approach to High Dynamic Range Imaging for Measurement Applications

Using the Advanced Sharpen Transformation

Techniques for Suppressing Adverse Lighting to Improve Vision System Success. Nelson Bridwell Senior Vision Engineer Machine Vision Engineering LLC

Bringing Answers to the Surface

CoE4TN4 Image Processing. Chapter 3: Intensity Transformation and Spatial Filtering

INTRODUCTION TO VISION SENSORS The Case for Automation with Machine Vision. AUTOMATION a division of HTE Technologies

Opto-digital Microscope. DSX Series. DSX Applications. High-resolution Upright scope. High-resolution Inverted scope. Free-angle Wide zoom scope

Thomas G. Cleary Building and Fire Research Laboratory National Institute of Standards and Technology Gaithersburg, MD U.S.A.

Quantitative Hyperspectral Imaging Technique for Condition Assessment and Monitoring of Historical Documents

Optimizing throughput with Machine Vision Lighting. Whitepaper

CPSC 4040/6040 Computer Graphics Images. Joshua Levine

Digital Image Processing

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

ROBOT VISION. Dr.M.Madhavi, MED, MVSREC

A Short History of Using Cameras for Weld Monitoring

CHAPTER-4 FRUIT QUALITY GRADATION USING SHAPE, SIZE AND DEFECT ATTRIBUTES

Image Processing Lecture 4

Color Science. What light is. Measuring light. CS 4620 Lecture 15. Salient property is the spectral power distribution (SPD)

Digital Image Fundamentals. Digital Image Processing. Human Visual System. Contents. Structure Of The Human Eye (cont.) Structure Of The Human Eye

Digital Image Fundamentals. Digital Image Processing. Human Visual System. Contents. Structure Of The Human Eye (cont.) Structure Of The Human Eye

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

DRAFT Direct View Display D-Cinema Addendum

Master thesis: Author: Examiner: Tutor: Duration: 1. Introduction 2. Ghost Categories Figure 1 Ghost categories

The Elegance of Line Scan Technology for AOI

High Resolution BSI Scientific CMOS

Digital Image Processing

CAMAG TLC VISUALIZER 2

Heads Up and Near Eye Display!

DISPLAY metrology measurement

Digital Photographic Imaging Using MOEMS

Leica DMi8A Quick Guide

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

Applying Automated Optical Inspection Ben Dawson, DALSA Coreco Inc., ipd Group (987)

Photometry and Light Measurement

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

NON UNIFORM BACKGROUND REMOVAL FOR PARTICLE ANALYSIS BASED ON MORPHOLOGICAL STRUCTURING ELEMENT:

An Efficient Color Image Segmentation using Edge Detection and Thresholding Methods

CS 548: Computer Vision REVIEW: Digital Image Basics. Spring 2016 Dr. Michael J. Reale

Chapter 2: Digital Image Fundamentals. Digital image processing is based on. Mathematical and probabilistic models Human intuition and analysis

The Noise about Noise

SYSTEMATIC NOISE CHARACTERIZATION OF A CCD CAMERA: APPLICATION TO A MULTISPECTRAL IMAGING SYSTEM

Color Measurement with the LSS-100P

Simulation of film media in motion picture production using a digital still camera

Sensors and Sensing Cameras and Camera Calibration

Face Detection System on Ada boost Algorithm Using Haar Classifiers

INTRODUCTION TO CCD IMAGING

Contents Technical background II. RUMBA technical specifications III. Hardware connection IV. Set-up of the instrument Laboratory set-up

T I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E

Improving the Detection of Near Earth Objects for Ground Based Telescopes

MEDICAL DEVICE & DIAGNOSTIC INDUSTRY. Increasing Product Yields with Automated Vision Systems. E. J. Claude and R. M. Carritte

Transcription:

Methods for Measuring Display Defects and Mura as Correlated to Human Visual Perception

Methods for Measuring Display Defects and Mura as Correlated to Human Visual Perception Abstract Human vision and perception are the ultimate determinants of display quality; however, human judgment is variable, making it difficult to define and apply quantitatively in research or production environments. Traditional methods for automated defect detection do not replicate human perception which is an issue particularly in identifying just noticeable differences. Accurately correlating human perceptions of defects with the information that can be gathered using imaging colorimeters offers an opportunity for objective and repeatable defect detection and quantification. By applying algorithms for just noticeable differences (JND) image analysis, a means of automated, repeatable display analysis directly correlated with human perception can be realized. Initial application of JND analysis provides data that allows a quantitative grading of display image quality for illuminated displays, supplementing other defect detection techniques. The implementation of this technique and typical results are presented in this paper. Keywords: mura, display defects, just noticeable differences, JND, imaging colorimeter Introduction Human perception is the ultimate standard for assessing display quality. However, the use of human inspection as a metrology method in display evaluation for either development or production is problematic because of the statistical variation between observations and observer. In particular, human vision is subjective, difficult to calibrate, unquantifiable, and difficult to replicate from observer to observer. This imprecision makes it difficult to apply standards consistently from inspector to inspector. This has implications when comparing various display designs and technology, especially over time, within a development environment. In a production environment this variability also makes it particularly difficult to uniformly apply standards to multiple sources throughout a supply chain. Depending on the tolerances applied, variability either increases the risk of accepting defective displays or failing good displays both of which represent added cost. Human inspection also lacks detailed quantitative information about defect types and occurences, especially since human observers tend to only classify the most obvious defects. The difficulty in applying automated defect detection using image analysis has been the lack of clear algorithms for defect classification directly correlated to human perception. Recent advances in modeling human visual sensitivity to display defects have allowed the development of a system for the automated detection of just noticeable differences (JND) for various display technologies. Based on a sampling of human observers, the JND scale is defined so that a JND difference of 1 would be statistically just noticeable; on an absolute scale, a JND value of 0 represents no visible spatial contrast and an absolute JND value of 1 represents the first noticeable spatial contrast which for display technologies allows the grading of display defects. By using a computer-controlled imaging colorimeter to capture data on spatial distribution of display image luminance and color, and then analyzing the data to create a JND map of the image, mura (or blemish) defects in a display image can be graded with a direct correlation to human visual perception. Recent advances in modeling human visual sensitivity to display defects have allowed the development of a system for the automated detection of just noticeable differences (JND) for various display technologies. Display defect detection performed using this type of system demonstrates that JND analysis is an effective means of obtaining additional information about display image quality that extends to other analysis techniques. This analysis system can be applied to any display type, including LCD, LED, and OLED displays. Just Noticeable Difference Characterization Currently, there are a number of commercial systems available that utilize imaging colorimeters to identify display non-uniformities in color and brightness, and discontinuities such as line and point defects. However, the problem of creating an automated system for the detection of more subtle defects that is well-matched to human perception has so far proved less tractable. This is in part because human perception of just noticeable differences in display artifacts is dependent on contextual factors, and standard display defect analysis algorithms, (based on methods such as setting thresholds and edge detection), are not directly correlated to human perceptions in these cases. 2 I Radiant Vision Systems, LLC

The Spatial Standard Observer (SSO) is a software algorithm developed by NASA that incorporates a simple model of human visual sensitivity to spatial contrast [1]. It was specifically created for display metrology applications, and identification of display mura, or blemishes. Factors that are included in this model are: spatial frequency (how fast spatial contrast varies), orientation (the angular orientation of the spatial contrast relative to the viewing plane defined by human eyes), and the observer s distance from the display being viewed. This algorithm has been adapted for use in Radiant Vision Systems ProMetric image analysis software to allow ready application to arbitrary display data captured by an imaging photometer or colorimeter. In general, the analysis technique can be applied to either a photopic or colorimetric measurement image; because the analysis method generates useful data for both brightness and color, we will generally refer to colorimetric images. A short synopsis of the SSO algorithm is as follows: The input to the algorithm is a pair of images: the test image and a reference image. The test image is an imaging colorimeter measurement, possibly containing mura. The reference image is computed from the test image as a low-pass filtered version of the test image designed to eliminate the mura. The difference between test and reference images is filtered by a contrast sensitivity function (CSF). The filtered image is then multiplied by an aperture function. The final step is a non-linear pooling of the resulting image over space to produce the JND image. The CSF is a measure of the visibility of different spatial frequencies at different orientations. It reflects the decline in human visual sensitivity at higher spatial frequencies and at very low frequencies, as well as the lower sensitivity at oblique orientations (the oblique effect). The aperture function models the decline in human visual sensitivity with distance from the point of fixation. Automated Measurement System Structure Automated measurement and analysis of displays with an imaging colorimeter requires combination measurement control and analysis software. The general structure of the system that we have developed for this application is shown in Figure 1. The key components of the system are: (1) a scientific-grade imaging colorimetry system; (2) PC-based measurement control software which both controls the imaging colorimeter and test image display on the device under test; and (3) a suite of image analysis functions that allow various tests to be run, including JND analysis. The result is a system that can be easily automated for a variety of display defects and delivers quantitative results including point and line defects as well as JND analysis. The software architecture used has as a basis a core set of measurement control modules that provide the interface with the imaging colorimeter and the display under test. A series of specific test functions is built on this base, using function calls to generate various measurements of white, red, blue, green display screens at various brightness settings for uniformity analysis, or of checkerboard patterns for contrast measurement. A consolidated user interface allows the selection of tests to be run as well as specification of test parameters and pass / fail criteria where relevant. For production applications the user interface supports both administrator mode, with full access to test specifications, and operator mode, which only allows test execution. Control PC User Interface Display Test Functions Display Control Display Under Test Figure 1 - Structure of an automated display measurement system, which consists of an imaging colorimeter and measurement control and image analysis software. The user interface allows the selection and management of the display test functions, which, in turn drive the display and imaging colorimeter through control interfaces. Imaging Colorimeter Control Imaging Colorimeter 3 I Radiant Vision Systems, LLC

The Use of Imaging Colorimeters for Measuring Displays The quality of the analysis of display mura is dependent on the quality of the data gathered by the imaging colorimeter. While such a system is conceptually simple, in practice careful attention must be paid to the design and calibration of the imaging colorimeter and to the measurement setup in order to yield accurate results. This is especially true for mura detection, although the standard image analysis algorithms for uniformity measurement, line defect detection, and point defect detection also require good input data as well as accurate data analysis to be meaningful. Imaging Colorimeter System Design The main components of an imaging colorimeter are an imaging lens, a set of color filters, a CCD detector, and data acquisition and image processing hardware/software [2]. Other elements may include neutral density filters and a mechanical shutter. To perform colorimetric measurements, the system acquires an image of the device under test through each of the various color filters. When needed, neutral density filters are employed to ensure that each color measurement uses the full dynamic range of the sensor. Photometric measurements are performed using only the green (photopic) filter. The image data is then processed using previously-determined calibrations to yield accurate color or luminance data for every pixel in the image. The spatial resolution of this data depends upon the imaging optics and sensor dimensions. The benefit of using an imaging colorimeter is that the luminance and color of every pixel in a display are measured simultaneously at a given view angle. The imaging colorimeter preserves the spatial relationship of measurements across the display, which is required for measuring spatial variations. Figure 2 - The ProMetric Imaging Colorimeter is typical of the test and measurement equipment used for display defect detection. The imaging colorimeter technology and resolution are usually selected based on the display specifications and the array of tests to be performed. Most tests are performed with the display normal to the imaging colorimeter, but the display may be rotated with respect to imaging colorimeter to obtain view angle data, including for JND analysis. In an alternative configuration, a conoscope lens mounted directly to an imaging colorimeter can achieve similar results by simultaneously evaluating all angular distributions of light to in a single measurement. Because an imaging colorimeter acquires multiple data points in a single measurement, it is inherently a much faster inspection solution than an approach based on individual spot measurements. In addition, simultaneously measuring the entire surface of the device under test makes it useful for gauging overall color and luminance uniformity, identifying very small defects, and grading the severity of defects as observed within the display in whole. The imaging colorimeter can even be used to render a processed image of the display, which can help to reveal subtle features (mura) for quantitative analysis, such as defect severity or position trending. Application to Display Performance Analysis The selection of an imaging colorimeter for specific display measurements will depend on display specifications, including pixel resolution and pitch, and measurement objectives, including whether uniformity-only or pixel-level defects are to be measured. Imaging colorimeter attributes that can be selected include CCD type (full frame or interline transfer), CCD resolution (greater resolution is usually required to identify pixel or sub-pixel defects), dynamic range, field of view (which will be 4 I Radiant Vision Systems, LLC

a function of CCD and lens choice), and measurement speed (where faster measurement speed usually means lower measurement accuracy). In our application of JND analysis for display defect detection, a ProMetric I8 Imaging Colorimeter was used with measurement control and test management functions performed by TrueTest Software. This software manages a full range of the visual and quantitative tests for qualifying display performance, as well as performing tests in sequence for in-line inspection. TrueTest includes tests for brightness and gamma correction, color correction, identification of general mura and pixel defects, brightness and color uniformity, contrast ratio, image quality, image size and location, convergence, and many other tests. For the study discussed in this paper, we incorporated a JND analysis test function into TrueTest. Test Set-Up Display testing must generally take place in a darkened environment. Either a dark room or a test tent must be used to provide the level of darkness necessary for accurate measurements. If a screen is being used (i.e., front projector system), then the environment must also have dark walls, ceilings, and floors to prevent stray light from reflecting off these surfaces onto the screen. This is particularly important during the illuminance calibration process. Dark curtains and floor coverings that have a textured surface work best for dampening the reflected light. In addition, some mechanism for positioning the display at the appropriate working distance from the imaging colorimeter must be implemented. This can either be done manually or with a mechanical system. Implementation of JND Algorithms for Automated Display Testing The JND analysis function processes a captured image of a display to generate a JND mapping of the image. The algorithm also outputs three JND metrics that may be used to grade the visual quality of the display. This has immediate value for production-line applications; for example, in both LCD fabrication facilities and final display assembly lines. The generated metrics are: (1) Aperture: The aperture function represents the fovea vision of the eye. Aperture is a localized metric that indicates the visibility of artifacts at each point in the image. The aperture JND metric at each pixel reflects the visibility of artifacts in a region in the neighborhood of that pixel, when the observer is fixated on that pixel. The output of the Aperture metric is thus an image (JND image). The Aperture metric is best suited to small local artifacts, such as typical spot mura. The Max JND metric is the maximum value found in the JND image. (2) Total JND is the result of a nonlinear pooling across the JND image. It gives an overall measure of the visibility of artifacts in the image. It is most useful when the image contains several artifacts at different locations in the image. (3) Single JND is a metric that works best with large extended artifacts that extend over a large region of the image. It is the result of a summation over the contrast image filter by the CSF (contrast sensitivity function) raised to a certain power. The aperture function is not applied in this metric, so it does not assume the observer is fixated on a small area. It produces only a single value, rather than an image. The JND analysis was implemented with a number of input options that are detailed in Table 1. The input options increase testing flexibility, allowing the JND analysis to be applied to a broad range of measurement situations. 5 I Radiant Vision Systems, LLC

Table 1. User selectable options implemented for JND analysis. Option or Parameter Down-Sample Description The image may be down-sampled to decrease the processing time. Down-sampling normally has small to negligible effect on the resulting JND values, unless the down-sampling is excessive. Typical values are 2x2. Save to Database Viewing Distance For example, 2x2 down-sampling will select every other row and column for processing. No averaging is done; the skipped rows and columns are simply ignored. When SaveToDatabase=True, the resulting JND image will automatically be saved to the current measurement database at the conclusion of the processing. In addition, a difference image will also be saved showing the contrast difference between the test image and a calculated reference image. In every case, the final JND image can be manually saved to the database by executing separately the SaveToDatabase image process. The viewing distance parameter is the approximate distance at which a human observer would evaluate the display. It is not the camera distance. The viewing distance value is specified in units of the display height. For example, a value of 2 indicates the viewing distance is equal to 2 times the height of display. Region of Interest TristimType Changing the viewing distance has the effect of making artifacts more or less visible. A small point defect may be visible at close viewing distance, but less visible or not visible when viewed from farther away. A region-of-interest (ROI) inside the measurement may be defined for mura analysis by dragging a rectangular region with the left mouse button on the bitmap image. The region-of-interest will appear as a solid white rectangle. It is not necessary to crop the measurement to this region-of-interest. The image process will utilize the image area defined by the white rectangle. If no region-of-interest is supplied by the user, the image process will automatically find the active display area in the measurement image, removing the dark border surrounding the image, if there is one. If there is not a well-defined edge defining the active display area, then the user should provide a region-of-interest. If a single tristimulus image (TrisX, TrisY, or TrisZ) is selected in the parameter table, then the image process will operate only on that tristimulus image. The other two tristimulus images will be dropped. If the TristimType selected is All, the image process will be applied to all three tristimulus images in the case of a color measurement; or to the TrisY image in the case of a monochromatic image. Measurement Examples The JND analysis algorithm defined above has been applied to many different display image samples to test its usefulness. In general, the technique has been demonstrated to work well in identifying mura; more importantly, the computed JND value provides a numerical assessment of the JND that can be used to grade different mura or displays. In Figures 3, 4, and 5, the application of the algorithm to a LCD display is shown. In this case a white screen image is processed. Two JND maps of the screen are shown: raw JND image, and a JND map with a color scale to distinguish between various levels. In Figures 6 and 7 the JND algorithm is applied to an LCD projector screen image. In this case, 6 I Radiant Vision Systems, LLC

very obvious mura at the upper center of the image is readily identified. In both cases we show the results of measuring an all-white display. The analysis can also be applied to any other uniform screen image, including black screens. Figure 3 - LCD screen measurement with gradients near the edges of the display and two mura near the center of the display. The mura at the center of the screen are faint and barely noticeable in the original image (of course, it helps to know that they are there!). Figure 4 - The raw JND analysis of the screen image (lighter for higher values of JND and darker for lower values) clearly shows the mura at the center of the screen. In addition, some artifacts light leakage and dark spots at the edge of the screen are also visible. This analysis highlights mura that were barely visible in the original image. Figure 5 - In a false-color representation of the JND map, it is clear that the two spots in the center of the display and some areas along the bottom of the display have JND values greater than 1 (the threshold value for being just noticeable ). The dark spot in the bottom right corner of the display has the largest computed JND value. The mottled area across most of the display apart from the mura at the center and along the edge represents JND values of about 0.7 or lower and could be smooth by setting a minimum threshold value. Figure 6 - An image taken of a white display from an LCD projector mura in the upper center of the screen image is readily visible. Figure 7 - The JND image computed from the LCD projector white screen measurement. The Max JND, Total JND, and Single JND values allow grading of various attributes of display performance. 7 I Radiant Vision Systems, LLC

Conclusions We have been able to demonstrate the application of the SSO algorithm for describing mura on a JND scale as a component of an automated system for display defect detection. As a standalone test, the algorithm has been applied to a variety of display technologies and has been demonstrated to be able to identify display mura effectively. Continuing application of the algorithm in analyzing real-world displays is required to understand its full potential. In addition, display mura does not generally exist in isolation. In a real-world testing environment, the measurement system must be able to identify physical defects such as a scratch or other display defects such as bad or stuck pixels and line defects. The coordinated combination of various tests, including one based on the SSO algorithm, provides the most promising approach to fully identifying and characterizing display defects. In addition, various mura identified by the algorithm may have different physical causes, so their remediation or implication for quality improvement is different. Therefore, the use of this analysis to not only identify and grade mura, but to extend it to classify the causes of the mura, is an area for further investigation. While the SSO algorithm was developed to describe display mura on a JND scale, we have also been able to apply it to other applications where noticeable changes in spatial contrast are meaningful, for example to characterize the uniformity of paper or paint finishes. Further application of this method to material characterization has broad interest for quality control. References [1] Watson, A.B., The Standard Spatial Observer: A new tool for display metrology, Information Display 23(1), (2007). [2] Rykowski, R. and Kostal, H., Imaging Colorimetry: Accuracy in Display and Light Source Metrology, Photonics Handbook (2008). 8 I Radiant Vision Systems, LLC

Correlating human perception of defects with data offers a unique opportunity to objectively detect and quantify display quality. By applying algorithms for JND image uniformity analysis, imaging colorimeters are able to perform efficient and repeatable automated inspections with equivalent optical sensitivity and tolerance for defects as compared with human inspectors. Contact Us Today Global Corporate Headquarters Radiant Vision Systems LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053 USA T. +1 425 844-0152 F. +1 425 844-0153 Greater China Radiant Vision Systems China, Ltd. B301 SOHO ZhongShan Plaza No.1065 West ZhongShan Road ChangNing District, Shanghai 200051 P.R. China T. +86 21 5242-2288 F. +86 21 5242-2066 B808 GuangHao International Center Phase II No. 441 MeiLong Road LongHua New District, Shenzhen 518131 P.R. China T. +86 755 2377-2596 Korea Radiant Vision Systems Korea LLC 12F, Seokun Tower 646 Sampeong-dong, Bundang-gu Seongnam-si, Kyunggi-do 463-400, Korea T. +82 31 8017-6797 RadiantVisionSystems.com Info@RadiantVS.com RadiantVisionSystems.com 2017 Radiant Vision Systems LLC. Radiant Vision Systems, ProMetric and TrueTest are trademarks of Radiant Vision Systems LLC. All other marks are the property of their respective owners.