Interior Wall and Floor Applications. / Mechanical Application / Fuga Fitted System. System Components:

Similar documents
FRP GATES MM08 FRP GATES Rev. 3 COMPOSITE SOLUTION PAGE 1

TECHNICAL DRAWING GUIDE

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

breathing walls Installation instructions

Butt Two pieces of wood meeting with flat sides adjoining usually at right angles. Some type of connector is needed to prevent movement.

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent

FAÇADES 2 - CT Assignment (circa 30 hours)

RECOMMENED TOOLS FOR MACHINING COUNTERTOPS

SLIDING DOOR SYSTEM_ S34 PRODUCT LIST. System description Accessories

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Installation instructions for co-extruded louver-board profiles

CURTAIN WALL OPTIONS UNITIZED CURTAIN WALL

ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

1. PREPARATION OF THE SUBSTRATE CLIMATIC CONDITIONS MARKING THE POSITION CUTTING GLUING 17 18

joining materials - wood

Installation Instructions

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

Joshua Woodsman

B Connectors. Automation. Structural Framing System Connectors & Fasteners

SAMPLE QUESTION PAPER III ENGINEERING GRAPHICS (046) Time Allowed: 3 hours Maximum Marks: 70

CETRIS facade systems

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

SDC PUBLICATIONS. Schroff Development Corporation

MN Modelling Objects and Creating Manufacturing Strategy

A Shell construction

Data Sheet 3820 Englisch

Clopay Models 835/837 Sliding Door System Installation Guide

WPC DECKING TERRACE BOARDS

ENGINEERING GRAPHICS

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

Moment Resisting Connections for Load Bearing Walls

SLIDING DOOR SYSTEM_ S42 PRODUCT LIST. System description Accessories

Independent Containment System (ICS)

Panels, Panel Mounting & Other Accessories

Laminate goes Wall. Installation documentation for wall panelling with gekko-system and Extravagant from CLASSEN.

HV Support System. The HV Support System is compatable with all CSS Support Systems:

ROOF CURB INSTALLATION INSTRUCTIONS: VERTICAL STANDING SEAM PANEL

Drawing Types & Construction Drawings

KS SERIES - VERTICAL INSTALLATION

MANUFACTURING, INTRODUCTION (620)

TUTORIAL 4: Combined Axial and Bending Problem Sketch Path Sweep Initial Project Space Setup Static Structural ANSYS

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

Connections in CLT Assemblies

Easy Step by Step Manual

TYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board

DECORATIVE BALUSTRADE

HSD-LD-US 06/13 Page 1/5. Components

Hex Bolts & Hex Screws DIN 931/ISO4014 & DIN 933/ISO4017

Architectural Interior Wall Paneling

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

Open Source Foam Cutter

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Marking Scheme Engineering Graphics

DRAWING INSTRUMENTS AND THEIR USES

BLACK WIDOW COMPOSITE

SECTION MANUFACTURED CASEWORK

Pneumatic & Hydraulic

PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground

Façade System Trimoterm FTV INVISIO

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

INSTRUCTION MANUAL FOR

The available roof cover choices are listed below: Fiberglass, Translucent Panels Steel. Shingles, Asphalt/Fiberglass, Irregular Pattern

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

STOLITE CONSTRUCTION SYSTEM EXT.CORNER - MANUF.STONE/STOLITE

Application Specification Releasable Poke-in Connector 08JUL 2015 REV:A

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

Inclined Roof System Trimoterm SNV

ALUMINUM PIPE GUIDERAIL 01/01/

BRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION

Downloaded from ENGINEERING DRAWING. Time allowed : 3 hours Maximum Marks : 70

1.) Type: VL-F Single compartment rectangular smoke extraction ducts and fittings

Typical 250 Series Center Drive Conveyor Configuration...3. Typical 250 Series End Drive Conveyor Configuration...4

Football Goals 7,32x2,44 m

Drawing nr. Contents of drawing Date Rev. date

Part 7 Assembling the X axis

Instructions - Stobel V2

Fir and pine wood (52 %) Portland cement (38 %) made by firing limestone and clay Water (9 %) Wood mineralisation substances (1 %)

Aspen Art Museum Creating Innovative Wood Structure

PRODUCT DATA CATALOG

ME1105 Engineering Drawing & Design

09/ /2016 HST-83 mm 135. Documentation set Page state Scale System Profile Page

CROSSBAR RAFTER ISOMETRIC

APPENDIX FENCE GENERAL NOTES

STEEL PIPE GUIDERAIL 01/01/

Drywall, Wood and Truss Uplift

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

SHIN KWANG HOT MELT CO., LTD.

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

Installation Instructions for Solar Snow Pad (SSP-T-3)

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

Installation Instructions - Model V4JSD 1

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

GLOSSARY OF TERMS SECTION 8

Open Up Your View With CABLE SYSTEMS

Scaffolding ACCESSORIES

LABORATORY MANUAL COMPUTER AIDED DESIGN LAB

Transcription:

System Components: Kalesinterflex Composite Facade Board Composite Facade Board: Composite facade board (Kalesinterflex Fit) composed with porcelain ceramic front face, 1000 x 3000 x 3 mm in dimensions, with back face laminated with fiber mesh and special epoxy resin. Front Layer Back Layer Adhesive Porcelain board of 1000 x 3000 x 3 mm Kalesinterflex or of smaller size (500 x 1500 mm, 330 x 1500 mm, etc.) Fiber mesh Special epoxy resin Bearing Construction L anchorages, vertical bearer T profiles, horizontal fuga profiles and fittings constitute the sub-construction of the system. L 50 x 70 x 4 mm l = 80-150 mm. 6063 alloy raw aluminum anchorage Vertical bearer profile 50 x 70 x 2 mm, 6063 alloy raw aluminum T profile Horizontal fuga profile 21.5 x 62 mm special cross section 6063 anodized aluminum profile Fuga cover profile 13 x 21 mm special cross section 6063 anodized aluminum clips Fittings > Wall - anchorage connection = 10 x 100 dowel + rod of appropriate type > - vertical bearer T profile connection = Bolt, nut, washer > Vertical - horizontal fuga profile connection = 4.8 x 16 mm screw > Horizontal fuga profile - Kalesinterflex connection = Polyurethane adhesive Application > According to survey made at the jobsite, Kalesinterflex panel layout design is drawn based on standard details. > s are fixed on the face according to the design prepared as above. > Vertical bearer aluminum T profiles are fixed on anchorages with bolts and nuts at a distance of approximately 8 to 15 cm to the face plane. > Horizontal bearer fuga profiles are fixed with screws on vertical bearer T profiles at prescribed horizontal axes defined in the design. > Kalesinterflex slabs prepared to size as defined in the design are fixed on horizontal fuga profile with polyurethane based adhesive. (Vertical joints must be 3 to 6 mm.)

Surface preparation and Application For construction applications of 50 x 150 cm or less, (single layer fibre enhanced) must be used and for larger dimensions Kalesinterflex Laminex (double layer laminated) must be used. In compliance with the design prepared, the horizontal supporting joint profiles where the dimensioned Kalesinterflex slabs (50 x 150 cm/free- 33 x 150 cm/free dimension ) will be mounted are fixed with YSB crews on the vertical supporting profiles, at the horizontal axis. Kalesinterflex slabs are mounted on the horizontal supporting joint profiles using polyurethane based adhesives. See Detail A. In an alternative practice, Kalesinterflex slabs (100 x 300 cm etc., Kalesinterflex Laminex of larger dimensions) are mounted, without using horizontal profiles, merely by fixing on vertical profiles with polyurethane based adhesives, to render surfaces in compliance with the details. See Detail B. The back surfaces of the dimensions Kalesinterflex slabs must be meshed or the slabs must be used after being laminated in two layers. Kalekim SeraCare is recommended for Kalesinterflex surface protection. It is useful particularly in rendering the cladding materials resistant against dirt and moss, facilitating future cleaning, and increasing resistance against water, thanks to its water repellent characteristics. Dimensions Product Adhesive* 100x300 cm 100x100 cm 50x150 cm 50x100 cm (4 mm) (4 mm) (4 mm) (4 mm) Mechanical System Interior Wall Applications; dimension-adhesive table.

Horizontal Fuga Profile Aluminum T Profile Thermal Insulation SECTION PLAN > Scale: 1/10 Adhesive Wall Dowel Horizontal Fuga Profile

Detail A > Scale: 1/10 Wall Bearer Profile Horizontal Fuga Profile Detail B > Scale: 1/10 Wall Bearer Profile Horizontal Fuga Profile

Fuga Fitted System / System Detail Plaster Wall Aluminum L Profile > Scale: 1/5 Aluminum L Profile Kalesinterflex Laminex Window Board

Fuga Fitted System / Internal Corner System Detail > Scale: 1/5 Plaster / External Corner System Detail > Scale: 1/5 Dowel Aluminum Corner Profile