Signet ph/orp Electrodes

Similar documents
Signet ph/orp Electrodes General Purpose

Signet 2750 DryLoc ph/orp Sensor Electronics

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

Signet 9950 Dual Channel Transmitter

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

Signet 9950 Dual Channel Transmitter

ph/orp Transmitter SIGNET

Bulb ph and ORP Electrodes

Signet ph/orp Transmitter * *

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

ph or ORP Transmitter

The transducer component converts the measured signal and displays the actual value.

Signet 9900 Transmitter

TUpH 396RVP and 398RVP Retractable ph/orp Sensors

Conductivity Transmitter

OPTISENS ORP 8590 Technical Datasheet

Signet 9900 Transmitter

Digital conductivity transmitter

Signet 9900 Transmitter

OPTISENS PH 8390 Technical Datasheet

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Quick Start Guide LIQ-QSG-226, Rev F June Rosemount 226. Toroidal Conductivity Sensors

8900 Multi-Parameter Controller

Memosens CPS96D. Technical Information

Condumax CLS21 and CLS21D

Signet 8900 Multi-Parameter Controller

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

Condumax CLS21 and CLS21D

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

SMARTPAT PH 1590 Technical Datasheet

Digital ORP sensor for the water and wastewater industry

Model Q40CT. System Features. Toroidal Conductivity Monitor...

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

Technical Information Condumax CLS21D/CLS21

Signet 2610 Process Optical Dissolved Oxygen Sensor

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

OPTISENS PH 8100 Technical Datasheet

SMARTPAT COND 1200 Technical Datasheet

* * Signet 2610 Process Optical Dissolved Oxygen Sensor. Operator's Manual. Introduction. English. System Description.

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Condumax W CLS15 and CLS15D

SMARTPAT ORP 8510 Technical Datasheet

Condumax CLS15 and CLS15D

Multi-Electrode Mounting (used for ph, Orp and Specific Ion) Honeywell Proprietary

Technical Information Orbipore CPS91D and CPS91

OPTISENS PH ph sensor. Technical Datasheet

Contents 1. Installation

Condumax CLS15 and CLS15D

Technical Information Condumax CLS15D/CLS15

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

HBPH-MK2 Brine/NH3 Leakage Sensor

Key Number I II III IV V _ - - _ - - _ - _, _,

ph / ORP Measurement mypro CPM 431

Measuring and Controlling Unit Multronic

General Purpose Toroidal Conductivity Sensors

Measuring and Controlling Unit Multronic OC

TECHNICAL DATA ELECTRO CHEMISTRY DIFFERENTIAL PH AND ORP. phd sc Digital Diferrential PH and ORP Sensors

Digital inductive conductivity transmitter

Condumax W CLS15 and CLS15D

Technical Information Memosens CPS96D

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Ceramax CPS341D. Technical Information

Digital flow ELEMENT transmitter for continuous flow measurement

Analytical Transmitters

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Process ph/orp Analysis Systems

inc Channel 1 ph, ORP (Redox) Conductivity or Dissolved Oxygen Transmitter Channel 2 Temperature Transmitter Black (V-) Green (V-)

Signet Flow Transmitter

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Indumax CLS50/CLS50D. Technical Information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Series 7777 Meredian II Electrode In-Line or Immersion Mounting

Electromagnetic Flow Transmitter

Conductivity sensor for hygienic applications

Valve Island with Electronic I/O

DissolvedOxygenMonitor

ABB ph/orp analyzer and probe package

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

Flow Measurement SITRANS F M

Digital ORP sensor for the industrial wastewater industry

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Digital flow ELEMENT transmitter for continuous flow measurement

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Industrial Conductivity (Electric Conductivity) Detector

Conductivity measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Metal Finishing. W600 Series Controllers. Summary of Key Benefits

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

TwO-wIRE TRANSmITTERS FOR ph, ORP, CONDUCTIvITy, OxygEN, OzONE, AND CHLORINE

SMARTPAT ORP 8150 Technical Datasheet

Transcription:

Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Protected Bulb Patented reference design for exceptional performance* Mounts in Signet standard fittings from DN15 to DN100 (½ to 4 in.) ¾ NPT or ISO 7/1-R 3/4 threaded sensors for use with reducing tees DN15 to DN100 (½ to 4 in.) Special design allows for installation at any angle, even inverted or horizontal Ryton (PPS) body for broad range of chemical compatibility Patented DryLoc connector with gold plated contacts Quick temperature response The Signet 2724-2726 ph and ORP Electrodes feature a patented reference design and uses the unique foul-proof patented DryLoc connector. The large area PE reference junction and pathway is constructed to increase the total reference effectiveness and ensures long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensor electronics. The robust Ryton threaded sensor body and choice of flat ph, bulb ph, or flat ORP sensing elements allows a broad range of chemical and mechanical compatibility for a wide variety of applications. There are two optional ph sensing versions available, HF and LC. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard ph glass in levels of ph 6 and below. The LC version can be used for low conductivity fluids 20-100 μs/cm nominal and below 20 μs when mounted under controlled conditions. The quick temperature response is available in either a PT1000 or 3 KΩ temperature sensor and allows compatibility with all Signet ph/orp instruments. The 2724-2726 electrodes are general-purpose sensors ideal for a wide range of applications. The sensors incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings, DN15 to DN100 (½ to 4 inch). Bulb and flat HF resistant glass available for trace HF, in less than 2% concentration applications Low conductivity sensor available for liquids down to 20 μs/cm Applications Water & Wastewater Treatment Neutralization Systems Effluent Monitoring Sanitization Systems Pool & Spa Control Aquatic Animal Life Support Systems Process Control Cooling Towers *U.S. Patent Nos.: 6,666,701, 7,799,193 B2, 7,867,371 B2 and 8,211,282 B2

General Performance Efficiency >97% @ 25 C (77 F) Operating Range ph 0 to 14 ph ORP ±2000 mv 3-2726-LC Low conductivity fluids; 20-100 μs/cm nominal < 20 μs; flow must be less than 150 ml/min in a properly grounded system 3-2724-HF, 3-2726-HF Hydrofluoric acid resistant glass, ph 6 or below; trace HF <2% Compatibility 2750 Sensor Electronics (for 8900, 9900, 4 to 20 ma or Profibus Concentrator), 2760 Preamplifier (8750) Temperature Sensor PT1000 versions Compatible with Signet 2750 ph/orp Sensor electronics for connection to a PLC or to the Signet 8900 or 9900 instruments 3 KΩ Balco versions Compatible with the Signet 2760 ph/orp preamplifier for connection to the Signet 8750 ph/orp Transmitter also compatible with the 2750 ph/orp Sensor Electronics Process Connection ¾ in. NPT ISO 7/1-R 3/4 Mounts into Signet fittings Wetted Materials ph Ryton (PPS), glass, UHMW PE, FPM ORP Ryton (PPS), glass, UHMW PE, FPM, Platinum Max. Temperature/Pressure Rating Operating Temperature Range* -10 C to 85 C 14 F to 185 F Operating Pressure Range 6.8 bar @ -10 to 65 C (100 psi @ 14 to 150 F) 4 bar @ 65 to 85 C (58 psi @ 150 to 185 F) *Best performance for 2724-HF, 2726-HF sensors is above 10 C (50 F) Recommended Storage Temperature 0 C to 50 C 32 F to 122 F The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Mounting In-line Mounting Use the sensor threads Use a Signet standard fitting up to 4 in. Sensor can be mounted at any angle Submersible Mounting Use threads on models 2750 or 2760 Requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded liquid tight extension conduit. Shipping Weight 0.25 kg 0.55 lb Standards and Approvals RoHS compliant, China RoHS Manufactured under ISO 9001 for Quality, ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety See Temperature and Pressure graphs for more information

Profibus Address Power 24 VDC 0.40A Max L IN L IN- PWR- PWR- PWR- PWR PWR PWR USB Signet 3-0486 Profibus Concentrator Channel 1 Channel 2 Channel 3 Channel 4 S 3 L Freq S 3 L Freq S 3 L Freq S 3 L Freq L IN L IN- N/C L OUT L OUT- N/C Out In Channel 7 Valve L IN L IN- S 3 L Loop Channel 6 S 3 L Loop Channel 5 * 0.64 mm (0.25 in.) 109 mm (4.3 in.) Threads: ¾ in. NPT or ISO 7/1 R-3/4 0 Horizontal 44.45 mm (1.75 in.) 18.3 mm (0.72 in.) 25.4 mm (1.0 in.) 9.3 mm (0.37 in.) 53.34 mm (2.1 in.) * Mounting Angle Models 2724-2726 may be mounted at any angle without affecting the performance. *Avoid locations with air pockets and sediment. When mounting in standard threaded fittings the electrode must be mounted horizontally to 60 degrees below horizontal position only. 90 180 0 YES YES 270 240 300 Panel Mount Signet Instruments 8750 with 2760 Preamplifier 8900 9900 with 2750 Electronics Pipe, Tank, Wall Mount Signet Instruments 9900 with 2750 Electronics and Rear Enclosure 4 to 20 ma Output 2750 Sensor Electronics and Customer Supplied Chart Recorder or Programmable Logic Controller or Programmable Automation Controller Automation System 2750 Sensor Electronics with 0486 Profibus Concentrator and Customer Supplied Programmable Logic Controller or Programmable Automation Controller System Overview OR Signet 2724-2726 DryLoc ph/orp Electrodes OR ENTER PLC PLC All sold separately In-Line Installation - Signet and threaded fittings only Submersible Installation - Customer supplied pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads* *Refer to the Signet Submersion Kit brochure (3-0000.707) located on our website for installation suggestions and options.

Electrode Key Features and Benefits: 5 1. Ryton body for chemical compatibility with most harsh chemicals. 2. Porous UHMW PE (ultra high molecular weight polyethylene) junction resists fouling and build-up. 3. Internal temperature sensor located in the glass stem for a quick temperature response. 4. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Resists moisture and dirt intrusion. 5. Dual-patented reference design with a 406 mm (16 inch) reference pathway enhances life. This enables the sensor to last significantly longer than other standard ph/orp electrodes in most applications. 5a. With the new patented reference design, the Signet 2726-LC version performs better in low conductivity water between 20-100 μs and lasts longer than previous DI electrodes. 5b. The 2726-LC sensor also performs in applications with extremely low (less than 20 μs) conductivity. Special precautions must be taken to avoid measurement complications. Please note the following. Electrostatic charges (streaming potentials) can cause dramatic offsets in a system with very low conductivity water. To minimize this, sensors should be placed in a well grounded system. To enhance performance, a low flow cell is recommended to provide a steady flow rate (150 ml/minute). Sensors placed in high flow applications will experience noisier readings due to streaming potential. 6. Threads for NPT or ISO process connection into reducing tees Use off-the-shelf GF reducing tees DN20 to DN100 (¾ to 4 in.). 7. Mounts directly into Signet fittings (½ in. 4 in.) for easy sensor retrofitting. 8. Mount submersed into a tank via the 2750 or 2760 back threads. 6 1 4 Sensor in threaded reducing tee 2 6 Dual-patented reference design for long life in conductivity or chemicals. 7 Sensor in Signet fitting 8 Sensor submersible installation www.gfsignet.com

Temperature/Pressure Graph Note: The pressure/temperature graphs are specifically for the Signet sensor. During system design the specifications of all components must be considered. In the case of a metal piping system, a plastic sensor will reduce the system specification. (psi) 150 125 (bar) 10.3 8.6 100 6.9 75 5.2 50 3.4 25 1.7 0 C -40-20 0 20 40 60 80 100 120 F -40-4 32 68 104 140 176 212 248 Application Tips Use the flat glass electrodes when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. Model 2724-2726 Ordering Notes 1) ph and ORP electrodes require connection to model 2750 sensor electronics or 2760 preamplifier. 2) The 2750 EasyCal feature recognizes common ph and ORP buffer values of 4, 7 and 10 ph and 87 and 264 mv for ORP. Buffer Solutions 3822-7004 3822-7007 3822-7010 Quinhydrone 3822-7115 The Signet ph buffers are ideal for calibration. The liquid solutions are conveniently packaged in one pint (473 ml) bottles. ph buffer kits in powder pillows are available for mixing fresh solutions with water at the time of use. All ph buffers are color coded for easy identification; 4.01 ph is red, 7.00 ph is yellow, and 10.00 ph is blue. All ph buffers are traceable to NIST standards. The 4.01 and 7.00 ph buffer solutions can be used to calibrate ORP sensors when saturated with quinhydrone.

Ordering Information Mfr. Part No. Code Tip Design Process Connection Thread Options ph Electrodes Temperature element PT1000; use with 2750 sensor electronics* and Profibus Concentrator 3-2724-00 159 001 545 Flat ¾ in. MNPT, Thread 3-2724-01 159 001 546 Flat ISO 7/1-R 3/4 Thread 3-2726-00 159 001 553 Bulb ¾ in. MNPT, Thread 3-2726-01 159 001 554 Bulb ISO 7/1-R 3/4 Thread 3-2726-HF-00 159 001 549 Bulb, HF Resistant¹ ¾ in. MNPT, Thread 3-2726-HF-01 159 001 550 Bulb, HF Resistant¹ ISO 7/1-R 3/4 Thread 3-2726-LC-00 159 001 557 Bulb, Low Conductivity² ¾ in. MNPT, Thread 3-2726-LC-01 159 001 558 Bulb, Low Conductivity² ISO 7/1-R 3/4 Thread Temperature element 3 KΩ Balco; Compatible with both the 2750 sensor electronics* and the 2760 preamplifier** 3-2724-10 159 001 547 Flat ¾ in. MNPT, Thread 3-2724-11 159 001 548 Flat ISO 7/1-R 3/4 Thread 3-2724-HF-10 159 001 771 Flat, HF Resistant¹ 3/4 in. NPT, Thread 3-2724-HF-11 159 001 772 Flat, ph Resistant¹ ISO 7/1-R 3/4 Thread 3-2726-10 159 001 555 Bulb ¾ in. MNPT, Thread 3-2726-11 159 001 556 Bulb ISO 7/1-R 3/4 Thread 3-2726-HF-10 159 001 551 Bulb HF Resistant 1 ¾ in. MNPT, Thread 3-2726-HF-11 159 001 552 Bulb HF Resistant 1 ISO 7/1-R 3/4 Thread 3-2726-LC-10 159 001 559 Bulb, Low Conductivity 2 ¾ in. MNPT, Thread 3-2726-LC-11 159 001 560 Bulb, Low Conductivity 2 ISO 7/1-R 3/4 Thread ORP Electrodes; Compatible with both the 2750 sensor electronics and the 2760 preamplifier 3-2725-60 159 001 561 Flat ¾ in. MNPT, Thread 3-2725-61 159 001 562 Flat ISO 7/1-R 3/4 Thread *The 2750 sensor electronics has a digital (S 3 L) output which is used with 8900 or 9900 instruments, and the Profibus Concentrator. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. **The 2760 preamplifier is used for connection directly to 8750 Transmitter or other analog transmitters. 1 HF resistant 2%HF ²Low conductivity applications, 20-100 μs/cm recommended Note: The 3K Balco temperature element electrodes are compatible with the 2750 Sensor Electronics, 8900 and 9900 instruments. Accessories and Replacement Parts Mfr. Part No. Code Description 1220-0021 198 801 000 O-ring, FPM (2 required per sensor) 3-2700.395 159 001 605 Calibration kit: includes 3 polypropylene cups, box used as cup stand, 1 pint ph 4.01, 1 pint ph 7.00 3822-7115 159 001 606 20 gm bottle quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) 3-2759 159 000 762 ph/orp System Tester (adapter cable sold separately) 3-2759.391 159 000 764 2759 DryLoc Adapter Cable (for use with 2750 and 2760) 3-0700.390 198 864 403 ph Buffer Kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) 3822-7004 159 001 581 ph 4.01 buffer solution, 1 pint (473 ml) bottle 3822-7007 159 001 582 ph 7.00 buffer solution, 1 pint (473 ml) bottle 3822-7010 159 001 583 ph 10.00 buffer solution, 1 pint (473 ml) bottle