SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA

Similar documents
5080A Multi-Product Calibrator

Testing & Calibration Lab, 204, Diamond Industrial Estate No. 2, Ketki Pada Road, (Near Dahisar Toll Naka), Dahisar (East), Mumbai, Maharashtra

Calsytech, # 38 North Mada Street Nandambakkam, Chennai, Tamil Nadu. Discipline Electro-Technical Calibration Issue Date

Technical Services Department, BHEL, Piplani, Bhopal, Madhya Pradesh. Discipline Electro Technical Calibration Issue Date

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10

5520A. Multi-Product Calibrator. Extended Specifications 2005

MPS Electrical Test Laboratory, Larsen & Toubro Limited, Mysore Campus, KIADB Industrial Area, Hebbal Hootagalli, Mysore, Karnataka

5520A. Multi-Product Calibrator. Extended Specifications

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

CERTIFICATE OF ACCREDITATION

Fluke 5820A Oscilloscope Calibrator Specifications

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

DECLARATION OF CONFORMITY

Chapter 6 Specifications

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

5500A. Multi-Product Calibrator. Extended Specifications 2005

7051Plus / 5051Plus. Extended Specification

5502A Multi-Product Calibrator. Extended specifications

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

5522A Multi-Product Calibrator Extended specifications

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Fluke 8845A/8846A Digital Multimeters Extended Specifications

Interpreting Specifications

Green LED (right of 'D' type connector)

CERTIFICATE OF ACCREDITATION

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

Solutions In Calibration TRANSMILLE PRODUCT GUIDE 2015/16 PROVIDING SOLUTIONS IN CALIBRATION WORLDWIDE. www. transmillecalibration.

HP 34401A Specifications 8

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION

8588A Reference Multimeter

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

Model Multimeter Specifications ABSOLUTE ACCURACY TYPICAL ACCURACIES 2002 SPECIFIED CALIBRATION INTERVALS

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

April 10, 2018 VIA . Gore Laboratories, Inc. Jeff Buechler 10 Northern Blvd., Suite 5 Amherst, NH 03031

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z

Agilent 34410A and 34411A Multimeters Setting the Standard for Next Generation Benchtop and System Testing

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

8845A/8846A 6.5 Digit Precision Multimeters

Manual Supplement Fluke Corporation. All rights reserved. Printed in U.S.A. x

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

SDM3045X Digital Multimeter. DataSheet

CERTIFICATE OF ACCREDITATION

TRACEABLE MEASUREMENT CAPABILITY

True RMS Bench Multimeters 2831E and 5491B

Multifunction Calibrator - Model 8080

Agilent 970-Series Handheld Multimeters Data Sheet

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Manual Supplement. Manual Title: 5520A Operators Supplement Issue: 2 Print Date: August 1998 Issue Date: 3/04 Revision/Date: 6, 1/03 Page Count: 3

Advanced Test Equipment Rentals ATEC (2832)

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By:

Precision Measurement Solutions

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

President For the Accreditation Council Certificate Number Valid to January 31, 2010

True RMS Bench Multimeter 5492B

ACCREDITED LABORATORY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 19

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF ACCREDITATION

1587/1577 Insulation Multimeters

CERTIFICATE OF ACCREDITATION

True RMS Bench Multimeter 5492B

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

CERTIFICATE OF ACCREDITATION

Calibration Techniques for the Home Lab

Traceability for Oscilloscopes and Oscilloscope Calibrators

Racal Instruments 4152A. 6.5 Digit Digital Multimeter. Product Information

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

CALIBRATION AND MEASUREMENT CAPABILITY (CMC) 1,2

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

True RMS Bench Multimeters 2831E and 5491B

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Transcription:

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA Técnicas para la calibración de medidores analógicos Bill Gaviria Regional Product Manager Direct: +1.425.446.5335 Cell: +1.321.626.7845 Email: bill.gaviria@flukecal.com 1

Difference Calibrating portable analog meters or analog panel meters can be challenging. These types of meters have low impedance that requires a high drive capability from the calibrator. A typical electrical calibrator might trip and display an error message: Compliance exceeded. Similar problems can occur when calibrating digital workload with low impedance. 2

Difference 3

Difference What is Compliance Voltage? Compliance voltage is the range of output voltage of a constant current power supply, over which the load regulation is within certain limits. It represents the maximum voltage a current source will reach as it attempts to produce the desired current. The compliance voltage equals the supply voltage minus the voltage drop due to the supply s internal resistance and usually specified at the full current of the supply. The supply voltage to the regulator input is usually higher than the compliance voltage by 1 Volt or higher depending on the type of the regulator. Source; Sunpower - Custom Power Supplies 4

Difference 5

Difference 6

Picture the Difference 7

Picture the Difference 8

Picture the Difference Power supply plus DMM equals a limited calibration solution! A power supply plus a bench digital multimeter provide the high compliance and accuracy required for analog meter calibration. However, this method has several drawbacks: Power supplies are usually noisy and not stable enough for calibration applications. If you want more stability, you have to pay for it a very stable power supply can easily cost more than $10,000 (U.S. dollars). To calculate uncertainty, you need to combine uncertainty of the DMM and short term stability of the power supply, which is not always provided by the power supply manufacturer. Power supplies have limited output ranges. For example, a dc power supply with a range of 100 Volts typically does not provide enough accuracy in the low 100 millivolt range. Depending on the ranges of the meters you need to calibrate, you might need multiple power supplies to do the job. Similarly, power supplies usually produce ac or dc power not both. So you ll need at least two power supplies to calibrate ac and dc functions. Power supplies have a V*A limitation in that high voltage and high current cannot be supplied simultaneously. Therefore, you need two power supplies to calibrate a VA meter. Finally, typical power supplies cannot be automated, so you cannot realize the improved consistency, efficiency and throughput that automation provides. 9

5080A Multi-Product Calibrator Calibration solutions for your analog and digital workload 10

A New Type of Calibrator The Fluke 5080A Multiproduct calibrator calibrates both your analog and digital workload accurately and economically. High current and voltage compliance for analog meter calibration Flexible accessories and options Protection circuitry against damaging input voltages software applications, including easy-to-use 5080/CAL software Functions DC Voltage AC Voltage DC Current AC Current Resistance Power MegOhm (option) Oscilloscope(option) 11

Expanded Workload Coverage The 5080A calibrates a wide workload that includes: Analog meters Panel meters 3½-digit and some 4½-digit DMMs Watt meters Clamp meters (with Fluke 9100-200 option or 5500A/COIL) Megohm meters / Insulation tester (with megohm option) Continuity testers (with megohm option) Oscilloscopes (with scope option) 12

Specifications Comparison Range, Best accuracy 1 Year Functions 5080A 9100 550X DC Voltage 0 V to 1020 V, 100 ppm 0 V to 1050 V, 60 ppm 0 V to 1020 V, 50 ppm AC Voltage 1 mv to 1020 V, 0.1 %, 45 Hz to 1 khz sinewave 0 V to 1050 V, 0.04 %, 10 Hz to 100 khz sinewave 1 mv to 1020 V, 0.03 %, 10 Hz to 500 khz sinewave DC Current 0 µa to 20 A, 0.05% 0 µa to 20A, 0.014 % 0 µa to11 A, 0.01 % AC Current 29 µa to 20 A, 0.1 %, 45 Hz to 1 khz sinewave Resistance 0 Ω to 190 MΩ, 0.025 % 20 values x1.0, x1.9 Power 1000 V and 20 A, 0.11 % DC and 0.25 % AC MegOhm 10 kω to18 GΩ, maximum voltage 1575 V (option) 0 µa to 20A, 0.07 %, 10 Hz to 30 khz sinewave 29 µa to 11 A, 0.06 %, 10 Hz to 10 khz sinewave 0 Ω to 400 MΩ, 0.015 % 0 Ω to 329.999 MΩ, 0.009 % 1050 V and 20 A, 0.03 % DC and 0.125 % AC (option) 100 kω to 2 GΩ, maximum voltage 1350 V (option) Oscilloscope 200 MHz (option) 250 MHz or 600 MHz (option) 1000 V and 11 A, 0.08 % DC and 0.15 % AC N/A 300 MHz or 600 MHz (option) Capacitance N/A 500 pf- 40 mf 330 pf-1.1 mf Temperature N/A Thermocouples and RTDs Thermocouples and RTDs 13

Picture the Difference Take direct voltage function as an example, the 5080A provides much higher current compliance while the 9100 and 550X provide better accuracy: Maximum Current Compliance at 30 V DC 5080A: 600 ma 10000 Direct Voltage 5080A, 1 year 5500A,1 year 9100, 1 year Specification, ppm 1000 100 9100: 20 ma 550X: 10 ma 10 0.01 0.1 1 10 100 1000 Direct Voltage Output, volts 14

Highest Compliance The Fluke 5080A has the highest compliance of any calibrator in the Fluke multi-product and multifunction families, making it an ideal solution for calibrating analog and panel meters. Function Maximum Burden or Compliance Voltage 5080A 9100 550XA 5522A 57XX 5730A Range DCV 600 ma 20 ma 10 ma 10 ma 50 ma 50 ma 0 to 33 V ACV 800 ma 20 ma 10 ma 10 ma 50 ma 50 ma 3.3 to 33 V DCI 50 V 4 V 4.5 V 7 V 10 V 10 V 0 to 33 ma ACI* 44 V 4 V 3 V 5 V 7 V 7 V 3.3 to 33 ma *AC LCOMP on 15

High Compliance Examples Calibrate low impedance voltage meters with high current compliance The Fluke 113 utility multi-meter has a low impedance function to simultaneously test for voltage or continuity 5522A trips to standby if voltage not ramped up slowly 5080A can directly output up to 300V DC and AC (45 Hz, 1 khz) Calibrate analog amp meter with high maximum inductive load The Yokogawa 2014 analog VA meter presents a high inductive load of 14 mh in the 150 ma range 5520A trips with error message compliance exceeded (at 60 Hz). With LCOMP on, the 5080A can easily drive the 2014 V-A meter s 150 ma range. 16

Protection 5080A s innovative protection circuitry prevents it from being damaged by reversed input voltage. Look before you leap Under standby mode, the 5080A will check for harmful voltage before it goes to operate. Under operating mode, the 5080A immediately detects harmful voltage at output terminals and automatically goes to standby. Resistant to mains voltage up to 240 V AC. Mains voltage inadvertently applied to a calibrator's output terminals can cause extensive damage requiring costly repairs. 17

Clamp Meter Calibration The Fluke 9100-200 option 10/50 turn coil or the 5500A/COIL 50 turn coil enables the 5080A to calibrate most popular clamp meters at currents up to 1000 A rms. The 9100-200 option 10 turn coil provides more flexibility for calibrating clamps with smaller jaws like the Fluke T5. 5500A/COIL 50TURN CURRENT COIL 9100-200 10/50 TURN CURRENT COIL 18

Power Calibration Simultaneously generates voltage and currents up to 1000 V and 20 A. AC frequency range 45-1000 Hz, power factor control 0-1. Calibrate Fluke-345 power quality clamp meter with 5080A and 5500A/COIL. Calibrate Yokogawa 2041 analog wattmeter with 5080A 19

MegOhm Option 5080A s MegOhm option calibrates insulation testers and continuity testers. Use 5320A 10kV Divider/R Multiplier to extend test voltage up to 10 kv. Specifications FUNCTION RANGE BEST UNCERTAINTY Insulation Resistance Resistance Voltage 10 kω to 18 GΩ Zero to 1575 V 0.2 % 1 % Continuity Current 10 ma DC peak Resistance Voltage Current 1 Ω to 5.9 kω (16 values) Zero to 70 V DC peak 700 ma max 0.1 % 1 % 20

Scope Option Add functionality with 200 MHz scope option Leveled sine wave generator up to 200 MHz for verifying bandwidth Fast edge rise time pulse generator (< 1 ns) for checking pulse response Time mark generator for verifying horizontal deflection characteristics Low freq squarewaves (voltage level to 1KHz) 21

Interface 5080A Standard Interface RS232 Ethernet 22

5080/CAL Software A Simple Solution to Automated Calibration A complete 5080A calibration solution Quick to learn Easy to use Procedure Designer Inventory and Calibration Record Management Procedures Database Export Data To excel, pdf, csv, html Calibrate With 5080A Generate Reports

A New High Value Calibrator High Compliance Wide Workload Coverage Protection Easy-to-Use 5080/CAL Software 24

25