Similar documents
The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

The future of installation testing is here. The 1650 Series Multifunction Testers

G SAFETY WARNINGS. LT300 High current loop tester. User guide

HT COMBI419. Innovative meter designed to perform all safety test

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT400 CAT IV Industrial Insulation Testers

1650 Series Multifunction Installation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400/2 CAT IV Insulation testers

MIT415 Insulation tester

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

1650 Series Multifunction Installation Testers

VIP ESI. Electrical Service Industry Voltage and Impedance Indicator. Instruction Manual & Specification

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Les Hampson Cert Ed FSCTE, Chairman CAI Technical Committee

HT FAMILY M70 METERS. Advanced DMM with safety and LAN cables test verifies HT ITALIA

MIT400 CAT IV Industrial Insulation Testers

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale:

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

Multi-Function Installation Tester MEGGER CM500. User Guide MEGGER

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

MEGGER CM300 MK II, CM400 MK II & CM500

MIT480/2 Insulation testers

HT FAMILY 2000 METERS. Integrated meter for test verifies on electrical installations

MEGGER BMM2000 Series Insulation Multimeters User Guide

BMM80 Premium Insulation Multimeters

MFT1700 series. Multifunction testers. User manual

UAT-600 Series. amprobe.com

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

Eurotest 61557, Instaltest 61557

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MIT400/2 CAT IV Insulation testers

MFT1800 series. Multifunction testers. User manual

MS2109A AC/DC Clamp Meter. User Manual. Contents

EurotestCOMBO MI 3125 / MI 3125E Short instructions Version 2.2, Code no

MFT1800 Series. Multifunction testers. User Manual

# Digital Multimeter

Fluke and

Fluke 1660 Series Multifunction Installation Testers

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

Fluke 1660 Series Multifunction Installation Testers

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Installation Tester BENNING IT 115. Operating Manual

MIT400 CAT IV Industrial Insulation Testers

Family 400 meters Rel /04/2007

PV210. Why buy the PV210?

INSTRUCTION MANUAL MARTINDALE EZ150 / EZ650 SOCKET TESTER 1. INTRODUCTION. ELECTRIC Trusted by professionals

Fluke 1650 Series. Multifunction Installation Testers. Extended Specifi cations. The installation testing solution for demanding environments

The first installation safety tester with automated testing based on patent pending AUTO SEQUENCE.

PV200. Why buy the PV200? The most compact I-V curve tracer around.

EurotestEASI MI 3100 SE MI 3100 s Instruction manual Version 1.1, Code no

MS2030 CAT III 600 V A V AUTO RS232

Measure voltage without test leads. Product Highlights

BENNING. CM7 Electrical Tester. Service Information

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

EurotestXE MI 3102H BT, MI 3102 BT Instruction manual Version 1.0, Code no

C.A 6117 C.A 6116N C.A 6113 Multi-function installation testers

GROUND TESTERS For all of your Ground Testing needs...

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations. Earth Fault Loop Impedance Tests

Agilent 970-Series Handheld Multimeters Data Sheet

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes or text books.

Multifunction AC/DC Voltage Tester

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Dawson DDM190. Digital Multimeter User s Manual

TT-SI 9001 / TT-SI MHz Active Differential Probes

ICM 136R Operating Instruction Electrical Clamp-Multimeter

3B SCIENTIFIC PHYSICS

TT-SI MHz DIFFERENTIAL PROBE

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Installation Tester BENNING IT 130. Operating Manual

2011 / Circuit Tracer

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

DDM350 Pen-Type Digital Multimeter User s Manual

VF3 AC Voltage detector. User Guide Guide de l utilisateur Bedienungsanleitung Guía del usuario

30XR-A Professional Digital Multimeter Users Manual

INSULATION TESTER SERIES

Installation Tester and DMM Kits

INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD.

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

Over 75 years of Japanese reliability and quality. Kyoritsu test and measurement

1507/1503. Insulation Testers. Technical Data. Features and benefits:

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Multifunction Digital

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DM-45 Digital Multimeter

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

INSTRUCTION MANUAL E1612 EARTH TESTER 1. INTRODUCTION

TT-SI MHz Active Differential Probe

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

TT-SI MHz Active Differential Probe

Transcription:

www.socketandsee.co.uk 200602

Put us to the Test! Socket & See are committed to providing the easiest to use testers on the market. All our testers are guaranteed against manufacturing defect for two years from date of purchase. New to Part P or Experienced Electrician? There is a simple grouping of Socket & See testers to point you in the right direction. If we take Insulation/Continuity testers as an example: PDIT 360 is an easy to use tester ideally suited to new comers to electrical testing and covers all the major tests required by the 16th Edition to meet Part P requirements. DIT 400 PLUS is also easy to use, but has 3 extra features the experienced electrician will value:- In addition to 250 and 500 volt insulation testing it has a 1000 volt range for testing in Industrial situations. SFS (Super Fast System) is a new go-no-go fast test - ideal for testing at the build stage of a property, thus saving time and money. It is also supplied complete with an SS 130, 13A socket interface which means not having to take the socket off the wall for testing. I found Fuse Finder really useful, and it is something I would make a lot of use of. Quality and Value Socket & See and MajorTech are dedicated to producing professional testers at prices that make sense! Designed for you! With our unique Socket & See values our testers have been designed for both the professional and newly qualified tradesman - Electricians, Plumbers, HVAC Engineers, for the tests you need to carry out every day. Mark Wildish Burdock Electrical, UK Before, I didn t think we would be finished with our task until the end of March. Now, with the Fuse Finder on the job, we should be wrapping up in a couple of weeks. Floyd H. Rodgers Director of Circuit Study, The Woodstock Opera House, USA A week ago I was busy testing and repairing some electrical problems at our garage. I was finished, for the day and was almost on my way home. I was just tidying up the DB box and pushing a wire into place, when there was a BIG flash!!! When I opened my eyes, the pair of long-nose pliers was lying about 6m from me. I do not know how it got out of my hand, but I was happy that it was OUT, and that I was still alive Lucky...? Although luck counts, I think it is because I bought a KEW TECHNIK tool! Thank you for saving my life. G Stander South Africa BEFORE AFTER Kew Technik is Quality Assured to ISO 9001 e-mail: sales@kewt.co.uk Tel: +44 (0)1256 864100 Fax: +44 (0)1256 864164 Socket & See (A division of the Kew Technik Group of companies) Prices: All prices shown in this brochure exclude VAT and are effective from 1 June 2006 Distributor Freephone Sales Order Fax 0800 7831385 Visit our websites www.socketandsee.co.uk www.major-tech.co.uk

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 Contents Insulation/Continuity Testers.........3/4 Multifunction..........5-12 Multifunction RCD Testers.........13/14 Test Kits.......................16/17 Digital Multimeters...............18-20 Clamp Meters...................21-23 Test Leads......................23-26 13A Socket Testers...............27-33 Industrial Socket Testers...........34-38 Phase Testers....................39-41 Fuse Finders....................42-46 Dead Circuit Finder..................47 Carrying Cases.....................48 Socket Tester Adaptors...............48 Voltage Testers..................49/53 Socket Opener.....................48 Test Documentation.................49 Thermometers......................50 Temperature Probes.................51 Temperature Monitoring Kits..........51 Light Meter........................52 Ultra-sonic Distance Meter...........52 A-Z Listing Model No. Price Page DCF 200 149.95 47 DIT 400 189.95 4 DIT 400 PLUS 199.95 4 DL 420 199.95 11 DL 420 PLUS 229.95 12 EIC 002 14.95 49 EPF 10 9.95 40 EPF 20 14.95 40 EPF 30 29.95 40 FFCB 100EU 54.95 43 FFCB 100UK 54.95 43 FFCB 1130UK 129.95 45 FFCB 1140UK 149.95 46 FFCB 200EU 99.95 44 FFCB 200UK 99.95 44 FFR HLT 5.95 41 IECP UKA 4.95 25 IT 001 14.95 26 ITLS 400 34.95 15/24 ITLS 440 29.95 25 ITLS 450 29.95 25 ITS 003 14.95 49 KTVT 100 14.95 53 MEW 001 14.95 49 MT 130 59.95 52 MT 1879A 84.95 20 MT 1887A 105.95 20 MT 2002PA 259.00 23 MT 21A 31.95 19 MT 22A 41.95 19 MT 24A 52.95 19 MT 2434 249.00 23 Model No. Price Page MT 400 14.95 53 MT 470 39.95 53 MT 630 59.95 50 MT 632 79.95 50 MT 650 159.00 51 MT 651 14.95 50 MT 652 179.00 51 MT 660 6.95 51 MT 670 29.95 51 MT 672 24.95 51 MT 675 29.95 51 MT 680 29.95 51 MT 685 29.95 51 MT 690 79.95 51 MT 694 89.95 50 MT 695 139.95 50 MT 730 69.95 22 MT 770 89.95 22 MT 777 159.95 22 MT 940 39.95 52 NCT 0314 4.95 49 NCT 0316 4.95 49 PDIT 360 179.95 3 PDL 200 79.95 6/33 PDL 234 89.95 7 PDL 234 PLUS 119.95 8 PDL 310 179.95 9 PDL 310 PLUS 199.95 10 PDRC 380 179.95 14 PIR 004 14.95 49 PKIT 300 549.00 17 SBX 4AA 2.95 48 Model No. Price Page SOK A20 19.95 26 SOK ADP40 19.95 48 SOK ADP50 19.95 48 SOK ADP60 29.95 48 SOK ADP65 33.95 48 SOK 12 9.95 29 SOK 13SO 0.49 48 SOK 22 14.95 29 SOK 32 19.95 29 SOK 40/16HD 29.95 36 SOK 40/32HD 34.95 36 SOK 42EU 29.95 31 SOK 42UK 29.95 31 SOK 420EU 89.95 32 SOK 420UK 89.95 32 SOK 50/16HD 29.95 35 SOK 50/32HD 34.95 35 SOK 60/TCN 64.95 38 SOK 60/16HD 54.95 37 SOK 60/32HD 59.95 37 SOK 605/16 29.95 48 SOK 605/32 33.95 48 SOK 65/16HD 59.95 37 SOK 65/32HD 64.95 37 SOK 72EU 69.95 41 SS 130 14.95 26 TECC 10 14.95 48 TECC 30 29.95 48 TECC 40 19.95 48 TECC 50 29.95 48 Contents FREE Easy step by step guides to successful Part P testing are available by mail or online at www.socketandsee.co.uk SEE OUR KEW TECHNIK TOOLS CATALOGUE STEP BY STEP GUIDE AVAILABLE INSULATION LOOP RCD 1

Insulation/Continuity Testers Insulation/Continuity Testers Insulation/ Continuity Testers PRODUCT DIT 400 PLUS 16th Edition Insulation/Continuity Tester DIT 400 16th Edition Insulation/Continuity Tester PDIT 360 Part P 16th Edition Insulation/Continuity Tester FEATURES Includes high quality test leads 5000 tests (@ 500V) from 4 AA cells Continuity test with full 200mA output Test lead null Insulation Test with full 1mA output 250 Volt test 500 Volt test 1000 Volt test SFS (Super Fast System) Insulation and Continuity SS 130 13A Socket Interface 2 www.socketandsee.co.uk PRICE 179.95 189.95 199.95

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 PDIT 360 Part P Insulation/Continuity Tester Full Part P verification 2 way-250, and 500 Volt insulation plus full 200mA continuity test Continuity measurement up to 10KΩ Uses only 4 x AA alkaline batteries giving over 5000 tests at 500V Supplied complete with quality test leads, carrying case and manual Fully protected against accidental live voltage contact up to 600V AC Null Function to eliminate lead resistance up to 2Ω Intelligent auto shut off to preserve battery life PART VERIFICATION EDITION BS EN 61557 FULLY CERTIFIED STEP BY STEP GUIDE INCLUDED PDIT 360 WHAT S INCLUDED Part P Insulation/ Continuity Tester 179.95 IT 001 Test Lead Kit Included PDITINS 360 Instruction Manual Included PDIT 360 179.95 Additional/spare Test Leads available - see page 23-25 413-02-12 & Table 41C Measurement of R1 + R2 413-04-01 to 07 Protection by non-conducting walls and floors 713-02 Continuity of protective conductors 713-03 Continuity of ring final circuit conductors 713-04-01 to 04 Insulation resistance 713-05-01 & 02 Site applied insulation 713-08-01 & 02 Insulation of non-conducting walls and floors 713-09 Polarity Insulation/Continuity Testers Insulation Test Ranges Accuracy Test Voltage Ranges (Auto Range) Tolerance (@20 0 C) 0.01 to 9.99MΩ ± 3% ± 1 digit 250V 10.0 to 99.9MΩ ± 3% ± 1 digit 100 to 199MΩ ± 6% ± 1 digit 0.01 to 9.99MΩ ± 3% ± 1 digit 500V 10.0 to 99.9MΩ ± 3% ± 1 digit 100 to 199MΩ ± 3% ± 1 digit 200 to 500MΩ ± 6% ± 1 digit Output Voltage Voltage Load Output Current Tolerance 250 250kΩ 1mA -0% +20% 500 500kΩ 1mA -0% +20% Short circuit current (in to 2kΩ) <2mA Typical Test Time (10MΩ) <2 sec Continuity Test Ranges Accuracy Ranges (Auto Range) Tolerance (@ 20 0 C) 0.00 to 9.99Ω ± 3% ± 2 digits 10.0 to 99.9Ω ± 3% ± 2 digits 100 to 999Ω ± 3% ± 2 digits 1000 to 9999Ω ± 3% ± 2 digits Open Circuit Voltage >4V, <10V Short Circuit Current >200mA Zero offset Adjust (Test Lead Null) 2Ω Typical Test Time (2Ω) <2 sec Power 4 x AA alkaline batteries (not included) Battery Life (BS EN 61557) >5000 tests @ 500V test voltage Environmental Operating Temperature Range............................ 0 0 C to 40 0 C Storage Temperature Range............................. -10 0 C to 60 0 C Operating Humidity...................... 80% @ 31 0 C to 50% @ 40 0 C Size...................................... 157mm x 89mm x 39mm Weight.................................................... 400g 3

Insulation/Continuity Testers Insulation/Continuity Testers DIT 400 PLUS 16th Edition Digital Insulation/Continuity Tester Full 16th Edition Certification New patented Super Fast System (SFS ) gives super fast time saving results As well as saving time, SFS greatly extends battery life 3 way-250, 500 and 1000 Volt insulation plus full 200mA continuity test Continuity measurement resolution 0.01Ω Uses only 4 x AA alkaline batteries giving over 5000 tests at 500V Supplied complete with quality test leads, carrying case and manual Fully protected against accidental live voltage contact up to 600V AC Null Function to eliminate lead resistance up to 2Ω Intelligent auto shut off to preserve battery life Contents DIT 400 16th Edition Insulation Continuity Tester 189.95 SS 130 Socket Interface 14.95 IT 001 Test Lead Kit Included DITINS 400 Instruction Manual Included 204.90 DIT 400 PLUS KITSAVER 199.95 PRICE with SS 130 Socket Interface Additional/spare Test Leads available - see page 23-25 ALSO AVAILABLE 413-02-12 & Table 41C Measurement of R1 + R2 WHAT S IN THE KIT DIT 400 (SS 130 not included) 189.95 413-04-01 to 07 Protection by non-conducting walls and floors 713-02 Continuity of protective conductors 713-03 Continuity of ring final circuit conductors 713-04-01 to 04 Insulation resistance 713-05-01 & 02 Site applied insulation 713-08-01 & 02 Insulation of non-conducting walls and floors 713-09 Polarity EDITION BS EN 61557 FULLY CERTIFIED SUPER FAST SYSTEM Insulation Test Ranges Accuracy (Cert mode) Test Voltage Ranges (Auto Range) Tolerance (@20 0 C) 0.01 to 9.99MΩ ± 3% ± 1 digit 250V 10.0 to 99.9MΩ ± 3% ± 1 digit 100 to 199MΩ ± 6% ± 1 digit 0.01 to 9.99MΩ ± 3% ± 1 digit 500V 10.0 to 99.9MΩ ± 3% ± 1 digit 100 to 199MΩ ± 3% ± 1 digit 200 to 500MΩ ± 6% ± 1 digit 0.01 to 9.9MΩ ± 3% ± 1 digit 1000V 10.0 to 99.9MΩ ± 3% ± 1 digit 100 to 399MΩ ± 3% ± 1 digit 400 to 999MΩ ± 6% ± 1 digit Output Voltage (Cert and SFS mode) Voltage Load Output Current Tolerance 250 250kΩ 1mA -0% +20% 500 500kΩ 1mA -0% +20% 1000 1MΩ 1mA -0% +20% Short circuit current (in to 2kΩ) <2mA Typical Test Time (cert mode) (10MΩ) <2 sec Typical Test Time (SFS mode) (10MΩ) <1 sec SFS Threshold 2MΩ Continuity Test Ranges Accuracy (Cert mode) Ranges (Auto Range) Tolerance (@ 20 0 C) 0.00 to 9.99Ω ± 3% ± 2 digits 10.0 to 99.9Ω ± 3% ± 2 digits 100 to 999Ω ± 3% ± 2 digits 1000 to 9999Ω ± 3% ± 2 digits Open Circuit Voltage >4V, <10V Short Circuit Current >200mA Zero offset Adjust (Test Lead Null) 2Ω Typical Test Time (Cert mode) (2Ω) <2 sec Typical Test Time (SFS mode) (2Ω) <1 sec SFS Threshold 10Ω Power 4 x AA alkaline batteries (not included) Battery Life (BS EN 61557) >5000 tests @ 500V test voltage 4 IT 001 SS 130 www.socketandsee.co.uk Environmental Operating Temperature Range............................ 0 0 C to 40 0 C Storage Temperature Range............................. -10 0 C to 60 0 C Operating Humidity...................... 80% @ 31 0 C to 50% @ 40 0 C Size...................................... 157mm x 89mm x 39mm Weight.................................................... 400g

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 PDL 200 PDL 234 PDL 310 PDL 234 PLUS DL 420 PDL 310 PLUS PRODUCT DL 420 PLUS Multifunction Loop Test Kit Multifunction Loop Tester FEATURES Multifunction Part P Loop Tester Multifunction Part P Loop Tester Multifunction Part P Loop Test Kit Multifunction 16th Edition Loop Test Kit Multifunction 16th Edition Loop Test No-trip Loop test Measures mains voltage Correct socket wiring test Correct Polarity safety test Circuit verification Direct LED readout of results Digital (LCD) readout of result Measures PFC (Prospective Fault Current) Uses impedance measurement for Loop/PFC Measures voltage phase - neutral Measures voltage phase - earth & neutral - earth Supplied with ITLS 400 fused test lead set PRICE 79.95 89.95 119.95 179.95 199.95 199.95 229.95 5

PDL 200 Multifunction Part P Loop Tester Easy to use Part P verification 4 in 1 digital tester - loop, mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection Accurate mains voltage measurement to latest BS 7697, HD 472 S1 Built in proven SOK 32 correct wiring indication - see page 30 for complete fault indication chart Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included WHAT S INCLUDED PDL 200 Part P Loop Tester 79.95 PDLINS 200 Instruction Manual Included PDL 200 79.95 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance PART VERIFICATION STEP BY STEP GUIDE INCLUDED Wiring Test Detects missing E or N (>15kΩ) Detects L-E or L-N swap Detects Live - Earth/Neutral reversal by use of Polarity Test Pad Fault indicated by chart on front of instrument Phase voltage measurement accuracy 1% and displayed on 3 LED s <207V AC LOW 207-253V AC STANDARD >253V AC HIGH Loop Test Continuous reading loop resistance (Rl + Re) with result displayed on 5 LED s Test current <15mA at 253V AC Range <1Ω <2Ω <20Ω <200Ω >200Ω Each breakpoint has an accuracy of ± 10% Test stops within 30ms if measured EARTH potential >25V AC and Earth Fault indication displayed Environmental Operating Temperature Range............................ 0 0 C to 40 0 C Storage Temperature Range............................ -10 0 C to 60 0 C Operating Humidity...................... 80% @ 31 0 C to 50% @ 40 0 C Size.......................... 140mm x 80mm x 31mm with fixed lead Weight................................................... 250g Standards CE Marked Complies with BS EN 61010-1: 300V Cat III Complies with BS EN 61326 (with amendment A1) 6 www.socketandsee.co.uk

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 PDL 234 Multifunction Part P Loop Tester Easy to use Part P verification 4 in 1 digital tester - loop, mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection Accurate mains voltage measurement to latest BS 7697, HD 472 S1 Built in proven SOK 32 correct wiring indication - see page 30 for complete fault indication chart Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included WHAT S INCLUDED PDL 234 Part P Loop Tester 89.95 IECP UKA 13A Plug to IEC Female Connector Included PDLINS 234 Instruction Manual Included PDL 234 89.95 Additional/spare Test Leads available - see page 23-25 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance PART VERIFICATION STEP BY STEP GUIDE INCLUDED AS USED BY... British Gas Wiring Test Detects missing E or N (>15kΩ) Detects L-E or L-N swap Detects Live - Earth/Neutral reversal by use of Polarity Test Pad Fault indicated by chart on front of instrument Phase voltage measurement accuracy 1% and displayed on 3 LED s <207V AC LOW 207-253V AC STANDARD >253V AC HIGH Loop Test Continuous reading loop resistance (Rl + Re) with result displayed on 5 LED s Test current <15mA at 253V AC Range <1Ω <2Ω <100Ω <200Ω >200Ω Each breakpoint has an accuracy of ± 10% Test stops within 30ms if measured EARTH potential >25V AC and Earth Fault indication displayed Environmental Operating Temperature Range............................ 0 0 C to 40 0 C Storage Temperature Range............................ -10 0 C to 60 0 C Operating Humidity...................... 80% @ 31 0 C to 50% @ 40 0 C Size.......................... 140mm x 80mm x 31mm with fixed lead Weight................................................... 250g Standards CE Marked Complies with BS EN 61010-1: 300V Cat III Complies with BS EN 61326 (with amendment A1) 7

PDL 234 PLUS Multifunction Part P Loop Testing Kit Everything you need for Part P compliance 4 in 1 digital tester - loop, mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection Accurate mains voltage measurement to latest BS 7697, HD 472 S1 Built in proven SOK 32 correct wiring indication - see page 30 for complete fault indication chart Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included PART VERIFICATION STEP BY STEP GUIDE INCLUDED AS USED BY... British Gas WHAT S IN THE KIT Contents PDL 234 Part P Loop Tester 89.95 ITLS 400 Fused Test Lead Set 34.95 IECP UKA 13A Plug to IEC Female Connector Included PDLINS 234 Instruction Manual Included 124.90 PDL 234 PLUS KITSAVER 119.95 PRICE 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance i See page 7 for Technical Specification IECP UKA ITLS 400 8 www.socketandsee.co.uk

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 PDL 310 Part P Multifunction Digital Loop Tester PART P Loop Test measurement including Prospective Fault Current 4 in 1 digital tester - loop (including PFC), mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection Instant readout of PFC (Prospective Fault Current) Built in proven SOK 32 correct wiring indication Accurate mains voltage measurement to latest BS7697 Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included WHAT S INCLUDED PDL 310 Part P Loop Tester 179.95 IECP UKA 13A Plug to IEC Female Connector Included PDLINS 310 Instruction Manual Included PDL 310 179.95 Additional/spare Test Leads available - see page 23-25 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance 713-12 Prospective fault current SLT SMART LOOP TEST PART VERIFICATION EDITION BS EN 61557 FULLY CERTIFIED STEP BY STEP GUIDE INCLUDED Wiring Test Detects missing E or N (>15kΩ) Detects L-E or L-N swap Detects Live - Earth/Neutral reversal by use of Polarity Test Pad Fault indicated by chart on front of instrument Phase - Neutral voltage measurement ± 1% ± 1V Loop Test No trip mode 3 wire testing Phase - Neutral - Earth all connected Test current <15mA at 253V AC Range Accuracy 0.00 to 9.99Ω ± 5% ± 5 digits 10.00 to 99.9Ω ± 4% ± 4 digits 100.00 to 500Ω ± 4% ± 4 digits PFC Measurement 10A - 9.99kA This is a calculated measurement whose accuracy is derived from the Loop Test result Over Voltage Protection 440V AC No damage - complete recovery Power 4 x AA batteries (not included) Battery life (BS EN 61557) > 10,000 test (or shelf life of batteries installed) Environmental Operating Temperature Range............................ 0 0 C to 40 0 C Storage Temperature Range............................. -10 0 C to 60 0 C Operating Humidity....................... 80% @ 31 C to 50% @ 40 C Size...................................... 157mm x 89mm x 39mm Weight.................................................... 400g 9

PDL 310 PLUS Multifunction Part P Loop Testing Kit 4 in 1 digital tester - loop (including PFC), mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection Instant readout of PFC (Prospective Fault Current) Built in proven SOK 32 correct wiring indication - see page 30 for complete fault indication chart Accurate mains voltage measurement to latest BS 7697, HD 472 S1 Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included SLT SMART LOOP TEST PART VERIFICATION EDITION BS EN 61557 FULLY CERTIFIED STEP BY STEP GUIDE INCLUDED WHAT S IN THE KIT Contents PDL 310 Part P Loop Tester 179.95 ITLS 400 Fused Test Lead Set 34.95 IECP UKA 13A Plug to IEC Female Connector Included PDLINS 310 Instruction Manual Included 214.90 PDL 310 PLUS KITSAVER 199.95 PRICE 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance 713-12 Prospective fault current i See page 9 for Technical Specification IECP UKA ITLS 400 10 www.socketandsee.co.uk

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 DL 420 16th Edition Multifunction Digital Loop Tester The ultimate 16th edition instrument 4 in 1 digital tester - loop (including PFC), mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection WHAT S INCLUDED DL 420 16th Edition Loop Tester 199.95 IECP UKA 13A Plug to IEC Female Connector Included PDLINS 420 Instruction Manual Included DL 420 199.95 Instant readout of PFC (Prospective Fault Current) Built in proven SOK 32 correct wiring indication - see page 30 for complete fault indication chart Accurate mains voltage measurement to latest BS7699 Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included Uses true impedance technique for accurate measurement of Loop and Prospective Fault Current (PFC) at origin Additional/spare Test Leads available - see page 23-25 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance 713-12 Prospective fault current SLT SMART LOOP TEST TRUE LOOP IMPEDANCE EDITION BS EN 61557 FULLY CERTIFIED Wiring Test Detects missing E or N (>15kΩ) Detects L-E or L-N swap Detects Live - Earth/Neutral reversal by use of Polarity Test Pad Fault indicated by chart on front of instrument Phase - Neutral voltage measurement ± 1% ± 1V Phase - Earth voltage measurement ± 1% ± 1V Neutral - Earth voltage measurement ± 1% ± 1V Loop Test No trip mode 3 wire testing Phase - Neutral - Earth all connected Test current <15mA at 253V AC Range Accuracy 0.00 to 9.99Ω ± 5% ± 5 digits 10.00 to 99.9Ω ± 3% ± 3 digits 100.00 to 500Ω ± 3% ± 3 digits High current mode 2 wire testing Phase-Neutral or Phase-Earth connected using true impedance measurement - auto test (hands free) is selectable. Range Accuracy 0.00 to 9.99Ω ± 3% ± 3 digits 10.00 to 99.9Ω ± 3% ± 3 digits 100.00 to 500Ω ± 3% ± 3 digits PFC Measurement 10A - 19.9kA This is a calculated result using the loop test measurement but it will be inherently more accurate than traditional methods as the test is of impedance not solely resistance Over Voltage Protection 440V AC No damage - complete recovery Power 4 x AA batteries (not included) Battery life (BS EN 61557) > 10,000 test (or shelf life of batteries installed) Environmental Operating Temperature Range............................ 0 0 C to 40 0 C Storage Temperature Range............................. -10 0 C to 60 0 C Operating Humidity....................... 80% @ 31 C to 50% @ 40 C Size...................................... 157mm x 89mm x 39mm Weight.................................................... 400g 11

DL 420 PLUS Multifunction 16th Edition Loop Testing Kit Everything you need for full Loop testing 4 in 1 digital tester - loop (including PFC), mains voltage, correct wiring, correct polarity Patented no-trip loop test technology Fully protected against accidental phase to phase connection Instant readout of PFC (Prospective Fault Current) Built in proven SOK 32 correct wiring indication Accurate mains voltage measurement to latest BS7697 WHAT S IN THE KIT Contents DL 420 16th Edition Loop Tester 199.95 ITLS 400 Fused Test Lead Set 34.95 IECP UKA 13A Plug to IEC Female Connector Included PDLINS 420 Instruction Manual Included 234.90 DL 420 PLUS KITSAVER 229.95 PRICE Unique Socket & See Polarity test gives ultimate overall system safety check Carrying case included Uses true impedance technique for accurate measurement of Prospective Fault Current (PFC) SLT SMART LOOP TEST TRUE LOOP IMPEDANCE EDITION BS EN 61557 FULLY CERTIFIED 313-01 Nature of supply (voltage measurement) 713-10 Earth electrode resistance 713-11 Earth fault loop impedance 713-12 Prospective fault current i See page 11 for Technical Specification 12 IECP UKA ITLS 400 www.socketandsee.co.uk

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 RCD Testers RCD Testers PRODUCT PDRC 380 RCD Tester FEATURES Tests 30mA and 100mA RCD s Full manual test selection Auto test (automatic sequence) x 1 I n trip test x 5 I n (30mA RCD) fast trip test x 1 /2 I n non trip test Clear read out with 0.1ms resolution PRICE 179.95 13

RCD Testers & Test Leads RCD Testers PDRC 380 Part P Multifunction Digital RCD Tester RCD Testing made simple! Easy to use with auto sequence (not auto test) or manual override - you are in control of the test Auto sequence test in line with latest NICEIC recommendations - x 1, x 5, x 1 /2 Guaranteed to test all common types of 30mA and 100mA RCDs Fully conforms with latest 16th edition and safety standards Built in proven SOK 32 correct wiring indication - see page 29 for complete fault indication chart Accurate mains voltage measurement to latest BS7697, HD 472 S1 Unique Socket and See polarity test gives ultimate overall system safety check WHAT S INCLUDED PDRC 380 Part P RCD Tester 179.95 IECP UKA 13A Plug to IEC Female Connector Included PDRCINS 380 Instruction Manual Included PDIT 360 179.95 Additional/spare Test Leads available - see page 23-25 713-13-01 Functional Testing PART VERIFICATION EDITION BS EN 61557 FULLY CERTIFIED STEP BY STEP GUIDE INCLUDED Features Type AC breakers 30ma breakers x1/2 x1 x5 test currents 100ma breakers x1/2, x1 test currents Unlimited number of RCD tests RCD test polarity change Auto / Manual test on both breakers Full socket test and mains polarity test Complies with EN61557 parts 1 and 6 (performance) Complies with EN61010 (safety) Complies with EN61326 (EMC) RCD Test Range (to EN61557-6) Supply voltage 195V 253V AC 50Hz Test current accuracy (1/2 I) 0% to 10% Test current accuracy (I, 5I) +0% to +10% Trip time accuracy Up to 1 second +/-(1% + 1ms) Over 1 second +/-(1% +10ms) Voltage measurement Range 5V to 440V +/-(2% + 1V) over the working frequency range of 50Hz +/-0.5% Socket test Detects opens, shorts, wrong wiring, phantom conditions, phase reversal, out of limits voltage. Fault Touch Voltage Test terminated if >25V Power 4 x AA batteries Alkaline recommended Battery life 10,000 tests Fitted fuse 32mm 0.25A (F) HBC Survives 440V over voltage test rated for 1 minute. Environmental Operating Temperature Range............................ 0 C to 40 C Storage Temperature Range........................... -10 C to +60 C Operating Humidity................................ 93% RH @ 40 C Size...................................... 157mm x 89mm x 39mm Weight.................................................... 400g 14 www.socketandsee.co.uk

Call +44 (0)1256 864100 Freefax Sales Order 0800 7831385 ITLS 400 IEC Fused Test Lead Set The safe way to connect to distribution boards, bus bars, luminaires and spur outlets Big leap forward in safety - no need to screw and unscrew prods and crocodile clips - just push on-pull off As well as advancing safety, new system gives big time savings New harmonised colour system of phase-brown, neutral-blue (with gentle reminder at strain relief of old red/black equivalents) Stackable earth crocodile clip means no more trying to get 2 crocodile clips onto the same measuring point GS 38 FUSED & TIPS WHAT S IN THE KIT Contents IEC Female Connector to 2 x Fused Prods - 1 brown, 1 blue + 1 x 4mm green stackable connector 2 x Push on tips - 1 brown, 1 blue 3 x Push on crocodile clips - 1 brown, 1 blue, 1 green ITLS 400 KITSAVER 34.95 PRICE Changing from crocodile clips to probes, with new ITLS 400 leads to test a luminaire. Test Leads New test leads. If you ve been using croc clips at a distribution board, and now want to test a luminaire you need to put on the probes to get into the connecting strip for the luminaire. Advantage! The crocodile clips just pull off...... and the probes just click back on, it could not be simpler! 35 seconds Making a connection to a small connector area to measure, say Prospective Fault Current. Advantage! The fuses remain in the probes at all times, therefore a good contact is always assured. Advantage! You are ready to go in an instant! Advantage! Remove probes in an instant, click live croc clip back on. Advantage! The connector has a small contact area, so you ll need to get two croc clips onto the same point. With the new leads you can use the piggy back system. Neutral combines with the earth means just one croc clip to connect. Advantage! Now you can simply connect, using just two croc clips, one on the live and a single combined neutral/earth onto any other point. SS 130 Socket Interface Connector Save time - leave the socket in place Safer - leave the socket in place No broken connections - leave the socket in place No damage to decoration - leave the socket in place SS 130 14.95 This product is designed for use by trained personnel for testing purposes only. It must not be used for any other purposes. 15