Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Similar documents
Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III

Auto Ref / Keratometer ARK-560A / 530A / 510A

Auto Ref/Kerato/Tonometer TONOREF 2

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

Handheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef

Excellent Measurement Accuracy ARK-530A / 510A AUTO REF / KERATOMETER

The TRIumph of Excellence

Intelligent Refractor RT-5100

Refractive Power / Corneal Analyzer. OPD-Scan III

Optical Biometer AL-Scan

Non-Mydriatic Auto Fundus Camera AFC-330

Optical Biometer. AL-Scan. US Edition

Intelligent Refractor RT-5100

Optical Biometer AL-Scan

Optical Biometer AL-Scan

Optical Coherence Tomography Retina Scan Duo

Faster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P)

Tabletop Refraction System TS-310

Non-Mydriatic Auto Fundus Camera AFC-330

SYSTEM CHART SC-1700 Pola / 2000

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

LM-1200 / 1000(P) AUTO LENSMETER

Satellite Tracer LT-1200 / 980

Optical Coherence Tomography. RS-3000 Advance / Lite

Smart Refractor RT-5100

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

Versatile Functionality RT-5100 SMART REFRACTOR

Optical Coherence Tomography. RS-3000 Advance

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1

Edging Station LE-700

Satellite Tracer LT-1200 / 980

Optical Coherence Tomography. RS-3000 Advance 2

HRK-7000 / HRK-7000A Auto Ref-Keratometer

DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000

ERK-9000 Auto Ref/Kertometer

HEAD OFFICE TOKYO OFFICE NIDEK INC. NIDEK S.A. NIDEK TECHNOLOGIES

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM

Marco TRS Total Refraction System

AUTO LENSMETER Model LM-600/600P/600PD OPERAT OPERA OR S MANUAL TOR S MANUAL

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

2Win Binocular Mobile Refractometer and Vision Analyzer

Original instructions. February P902A Printed in Japan


: 34-14, Maehama, Hiroishi-cho, Gamagori, Aichi , Japan (Manufacturer) Telephone: (0533) Facsimile: (0533) : 6th Floor,

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Explanation of Aberration and Wavefront

Original instructions. October P932A Printed in Japan

OPHTHALMIC. REFRACTION LENSMETERS SLIT LAMPS ACUITY CHARTS RETINAL CAMERAS EXAM LANES & FURNITURE SURGICAL MICROSCOPE

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Dr. Magda Rau Eye Clinic Cham, Germany

ATLAS Corneal Topography System

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

Page 1

OCULUS Binoptometer 4P

Subjective refraction OPTICS OF HUMAN EYE & REFRACTIVE ERRORS

Clinical Update for Presbyopic Lens Options

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

OpenStax-CNX module: m Vision Correction * OpenStax

Auto Kerato-Refracto Tonometer TRK-2P

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

The Aberration Structure of the Keratoconic Eye

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009

Multifocal and Accommodative

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

The pattern scanning multi-color photocoagulator that puts you in control

Keratoconus contact lenses

Wave-Front Analyzer KR-1W

Trouble Shooting Guide for Ortho-K lenses

Fitting Manual Use with kerasofttraining.com

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Subjective refraction

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER

ROTATIONAL STABILITY MAKES THE DIFFERENCE

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

3.0 Alignment Equipment and Diagnostic Tools:

Wearable Adaptive Refractor. Innovative, Electronic, Mobile and Wearable System of Adaptive Lenses.

Principles and clinical applications of ray-tracing aberrometry (Part II)

Fitting Manual Use with

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

AUTO DRILLING UNIT. Model OPERATOR S MANUAL

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

DESIGNED FOR SUCCESS...GUARANTEED TO FIT

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Distribution of Refractive Error. 20 year old males. Distribution of Aberrations

PREMIUM LENSES WITH VARIABLE BASE CURVE

(495) (495)

Transcription:

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

The Superior Auto and Auto What is the superior auto ref / The ARK-1 / AR-1 series speak for themselves, and auto refractometer generating greater accuracy Superior Functions Accurate Refraction Measurement Simple Opacity Assessment Model Refraction measurement ARK-1s ARK-1a ARK-1 AR-1s AR-1a AR-1 -Available -Not available Keratometry measurement

Ref / Keratometer Refractometer keratometer and auto refractometer? surpassing a conventional auto ref / keratometer with technologically enhanced functions and greater clinical information. for Superior Outcomes Easy VA Measurement with Glare Test Patient-friendly Accommodation Measurement VA measurement Glare test Opacity assessment Accommodation measurement

Accurate Refraction Measurement VA Measurement with Glare Test Large Pupil Zone Imaging Method VA Measurement with Built-in Charts and Lenses (available for the ARK-1s and AR-1s) The large pupil zone imaging method enables the measurement of wide area refraction of up to 6 mm diameter and can indicate the difference between wide area refraction and the central area refraction of up to 3.5 mm diameter. The pupil diameter is measured simultaneously. The difference of the measurement allows assessment of the effect of pupil size such as a vision in dim light. The ARK-1s / AR-1s provides visual acuity (VA) measurement. This unique function enables a quick check of the patient's refractive error by comparing subjective measurement with objective measurement. Even corrected near visual acuity is measurable with easy operability to determine the need for a progressive lens. ø1 to 3.5 mm area ø1 to 4 mm area ø1 to 6 mm area Recall Function for Instant Vision Comparisons (available for the ARK-1s / 1a / 1 and AR-1s / 1a) The recall function provides the instant comparison between vision corrected with AR data and uncorrected vision or vision corrected with the data of patient s own glasses. For the patient, this function demonstrates the difference in vision and the necessity for more appropriate vision correction. ARK-500 / AR-300 series ARK-1 / AR-1 series Pupil zone imaging method Large pupil zone imaging method Distance vision corrected with AR data Near vision corrected with AR data Uncorrected distance vision Distance vision corrected with LM data* Uncorrected near vision Near vision corrected with LM data* *The data of patient s own glasses has to be imported from a NIDEK lensmeter. Vision comparisons Contrast and Glare Test (available for the ARK-1s and AR-1s) Super Luminescent Diode and Highly Sensitive CCD Incorporation of the Super Luminescent Diode (SLD) provides a sharper and clearer image compared to a conventional LED. The highly sensitive CCD detects the ring image even if the fundus reflection is weak. The system combining the SLD and highly sensitive CCD significantly improves measurement capability even in dense cataractous eyes. Hyperopia Emmetropia Myopia After a low contrast VA chart is projected, a glare source is projected beside the chart and the glare VA can be measured. With this test the effect of glare and halo to visual performance can be measured. This utility can be used for cataract and refractive surgery patients. Simulated patient s vision of low contrast VA chart Vision with glare and halo Normal vision Simulated patient vision of VA chart and glare source Half mirror Astigmatism Eye Astigmatism Simulated ring image SLD (normal eye) LED (normal eye) Keratometry Measurement with Mire Ring (available for the ARK-1s, ARK-1a, and ARK-1) Reflective mirror The mire ring is used to measure keratometry. It reduces eyelid artifacts. Ring lens Emitted SLD light Reflected light SLD SLD (cataractous eye)* Highly sensitive CCD LED (cataractous eye)* Captured ring image * In-house data of a cataractous model eye Measurement with four points Optimal Fogging to Minimize Accommodation (available for the ARK-1s / 1a and AR-1s / 1a) Fogging is performed after correcting the patient s astigmatism with built-in cylinder lenses. This allows the patient to view the target clearly and minimizes the interference with accommodation even in high astigmatism. Measurement with mire ring

Accurate Refraction Measurement VA Measurement with Glare Test Large Pupil Zone Imaging Method VA Measurement with Built-in Charts and Lenses (available for the ARK-1s and AR-1s) The large pupil zone imaging method enables the measurement of wide area refraction of up to 6 mm diameter and can indicate the difference between wide area refraction and the central area refraction of up to 3.5 mm diameter. The pupil diameter is measured simultaneously. The difference of the measurement allows assessment of the effect of pupil size such as a vision in dim light. The ARK-1s / AR-1s provides visual acuity (VA) measurement. This unique function enables a quick check of the patient's refractive error by comparing subjective measurement with objective measurement. Even corrected near visual acuity is measurable with easy operability to determine the need for a progressive lens. ø1 to 3.5 mm area ø1 to 4 mm area ø1 to 6 mm area Recall Function for Instant Vision Comparisons (available for the ARK-1s / 1a / 1 and AR-1s / 1a) The recall function provides the instant comparison between vision corrected with AR data and uncorrected vision or vision corrected with the data of patient s own glasses. For the patient, this function demonstrates the difference in vision and the necessity for more appropriate vision correction. ARK-500 / AR-300 series ARK-1 / AR-1 series Pupil zone imaging method Large pupil zone imaging method Distance vision corrected with AR data Near vision corrected with AR data Uncorrected distance vision Distance vision corrected with LM data* Uncorrected near vision Near vision corrected with LM data* *The data of patient s own glasses has to be imported from a NIDEK lensmeter. Vision comparisons Contrast and Glare Test (available for the ARK-1s and AR-1s) Super Luminescent Diode and Highly Sensitive CCD Incorporation of the Super Luminescent Diode (SLD) provides a sharper and clearer image compared to a conventional LED. The highly sensitive CCD detects the ring image even if the fundus reflection is weak. The system combining the SLD and highly sensitive CCD significantly improves measurement capability even in dense cataractous eyes. Hyperopia Emmetropia Myopia After a low contrast VA chart is projected, a glare source is projected beside the chart and the glare VA can be measured. With this test the effect of glare and halo to visual performance can be measured. This utility can be used for cataract and refractive surgery patients. Simulated patient s vision of low contrast VA chart Vision with glare and halo Half mirror Astigmatism Eye Astigmatism Simulated ring image SLD (normal eye) LED (normal eye) Keratometry Measurement with Mire Ring (available for the ARK-1s / 1a / 1) Reflective mirror The mire ring is used to measure keratometry. It reduces eyelid artifacts. Ring lens Emitted SLD light Reflected light SLD SLD (cataractous eye)* Highly sensitive CCD LED (cataractous eye)* Captured ring image * In-house data of a cataractous model eye Measurement with four points Optimal Fogging to Minimize Accommodation (available for the ARK-1s / 1a and AR-1s / 1a) Fogging is performed after correcting the patient s astigmatism with built-in cylinder lenses. This allows the patient to view the target clearly and minimizes the interference with accommodation even in high astigmatism. Normal vision Simulated patient vision of VA chart and glare source Measurement with mire ring

Patient-friendly Accommodation Measurement (available for the ARK-1s / 1a and AR-1s / 1a) Accommodation Measurement with Artificial Intelligence Algorithm Objective measurement of accommodation is performed with patient s focusing on a target which moves from distance to near. The artificial intelligence algorithm detects the patient s response and reduces the measurement time in cases with a slow or weak accommodative response. The accommodation measurement helps to assess pseudomyopia, eyestrain, and accommodative palsy. Amplitude of accommodation Accommodation graph Pupil diameter graph Measurement with Astigmatism Correction Astigmatism is corrected with built-in cylinder lenses prior to measurement. It reduces the influence of astigmatism on the measurement of accommodation. Assessment for Intermediate or Near Vision Lens The assessment of accommodation based on the age-accommodation relation allows to suggest whether an intermediate or near lens is required. Amplitude of accommodation (D) 14 12 10 8 6 4 2 0 0 10 20 30 40 50 60 70 80 Age (year) Courtesy of Masayoshi Kajita, MD, PhD The amplitudes of accommodation on the graph are values of subjective measurement. The amplitudes of accommodation of objective measurement tend to be lower than those on the graph. Simple Opacity Assessment Retroillumination Image and NIDEK Cataract Indices* The retro illumination image enables the observation of opacity of the optical media of the eye. NIDEK cataract indices indicate the severity of the opacity and helps to assess the progression of pathology. COI.H Opacity size within a diameter of 3 mm of the center (vertical diameter): mm COI.A Opacity proportion within a diameter of 3 mm of the center: % Eye with dense opacity POI Opacity proportion within the entire periphery: % Cataract indices *Available for the ARK-1s / 1a and AR-1s / 1a The NIDEK Cataract indices are for reference only. The following conditions may indicate different indices from ones of actual status. Peripheral image is darkly captured due to alignment position. Opacities are not in focus. Bright spot reflecting observation light occurs on the cornea apex. Position of the 3 mm diameter circle is shifted due to incorrect pupil detection caused by opacity location. Eye with light opacity

Practical and User-friendly Features 3-D* Auto Tracking and Auto Shot The 3-D auto tracking and auto shot provide faster, simpler, and more accurate measurements. When alignment is performed correctly, measurement starts automatically. Y direction *Y direction (vertical) auto tracking is available for the ARK-1 and AR-1. FOCUS X direction Tiltable Color LCD Screen The color LCD with tilt function offers easy operation even when an operator is standing. High Speed Printer with Easy Loading & Auto Cutter The printer paper can be changed easily. The data sheet is cut by an auto cutter for quick and easy detachment. Summary Display and Printout of Measured Values Various measured values can be displayed simultaneously on the summary screen allowing easy and quick confirmation and printing. Eye Care Card System* A card slot enables the use of an Eye Care card system, which provides quick and easy wireless data transfer. *The card is optional. Eye Care Card System

ARK-1 / AR-1 Series Specifications Model Auto refractometer Measurement range Minimum measurable pupil diameter Auto keratometer*1 Measurement range Sagittal measurement VA measurement Measurement mode Measurement range Correction range Vision comparison Retroillumination image Accommodation measurement range PD measurement range Corneal size measurement range*4 Pupil size measurement range Auto tracking Auto shot Display Printer Interface Power supply Power consumption Dimensions / Mass *1 Not available for the AR-1s, AR-1a, and AR-1 *2 Available with scenery chart for the ARK-1 *3 Not available for the AR-1 *4 Not available for the AR-1s, AR-1a, and AR-1 *5 The Eye Care card is optional. ARK-1s / AR-1s ARK-1a / AR-1a ARK-1 / AR-1 Sphere -30.00 to +25.00 D (VD = 12 mm) (0.01 / 0.12 / 0.25 D increments) Cylinder 0 to ±12.00 D (0.01 / 0.12 / 0.25 D increments) Axis 0 to 180 (1 / 5 increments) ø2 mm Curvature radius 5.00 to 13.00 mm (0.01 mm increments) Refractive power 25.96 to 67.50 D (n = 1.3375) (0.01 / 0.12 / 0.25 D increments) Cylindrical power 0 to ±12.00 D (0.01 / 0.12 / 0.25 D increments) Axis 0 to 180º (1 / 5 increments) 25º each from the center (superior side, inferior side, temporal side, nasal side) Uncorrected VA, Corrected VA (distance, near) Less than 0.1, 0.1, 0.25, 0.32, 0.4, 0.5, 0.63, 0.8, 1.0, 1.25 or Less than 20 / 200, 20 / 200, 20 / 80, 20 / 60, 20 / 50, 20 / 40, 20 / 30, 20 / 25, 20 / 20, 20 / 16 Sphere -20.00 to +20.00 D (VD = 12 mm) (0.25 D increments) Cylinder 0 to ±8.00 D (0.25 D increments) Axis 0 to 180º (1º / 5º increments) Available with VA chart Available 0 to 10.00 D (0.01 / 0.12 / 0.25 D increments) 30 to 85 mm (1 mm increments) (Near point PD: 28 to 80 mm at WD = 40 cm) 10.0 to 14.0 mm (0.1 mm increments) 1.0 to 10.0 mm (0.1 mm increments) X-Y-Z directions Available Tiltable 6.5-inch color LCD Thermal line printer with easy loading and auto cutter RS-232C (in / out), LAN, USB, Eye Care card system*5 AC 100 to 240 V 50 / 60 Hz 100 VA 260 (W) x 495 (D) x 457 (H) mm / 20 kg 10.2 (W) x 19.5 (D) x 18.0 (H)" / 44 lbs. Not available Available with scenery chart Not available Available*2 / Not available*3 Not available Not available Y direction Product / Model name: Auto Ref / Keratometer ARK-1s / 1a / 1 Auto Refractometer AR-1s / 1a / 1 Caution: U.S. Federal Law restricts this device to sale, distribution, and use by or on the order of a physician or other licensed eye care practitioner. The NIDEK cataract indices are not available in USA. Specifications may vary depending on circumstances in each country. Specifications and design are subject to change without notice. HEAD OFFICE (International Div.) 34-14 Maehama, Hiroishi Gamagori, Aichi 443-0038, Japan TEL: +81-533-67-8895 URL: http://www.nidek.co.jp [ Manufacturer ] TOKYO OFFICE (International Div.) 3F Sumitomo Fudosan Hongo Bldg., 3-22-5 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan TEL: +81-3-5844-2641 URL: http://www.nidek.com NIDEK INC. 47651 Westinghouse Drive Fremont, CA 94539, U.S.A. TEL: +1-510-226-5700 +1-800-223-9044 (US only) URL: http://usa.nidek.com NIDEK S.A. Europarc 13, rue Auguste Perret 94042 Creteil, France TEL: +33-1-49 80 97 97 URL: http://www.nidek.fr NIDEK TECHNOLOGIES Srl Via dell'artigianato, 6 / A 35020 Albignasego (Padova), Italy TEL: +39 049 8629200 / 8626399 URL: http://www.nidektechnologies.it NIDEK (SHANGHAI) CO., LTD. Rm 915, China Venturetech Plaza, No.819 Nanjing West Rd, Jing An District, Shanghai China 200041 TEL: +86 021-5212-7942 URL: http://www.nidek-china.cn NIDEK SINGAPORE PTE. LTD. 51 Changi Business Park Central 2 #06-14 The Signature Singapore 486066 TEL: +65 6588 0389 CNIDEK 2013 Printed in Japan ARK-1 / AR-1 3