MODEL 8080PR3 Released on 11th Mar 2013

Similar documents
User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

Instruction Manual Inductive Gauging Sensor

1523, 1524 Thermometer Readout User s Guide

Radio Remote Controls Manual K Series

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

8003 1/8 DIN Temperature Controller

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

742A Series Resistance Standards

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

CDT. Service and Installation Manual. Manual Revision Oct 2014

LBI Mobile Communications MDX DESK TOP STATION. Operator's Manual

Starbox. Installation guide

Indoor Contact Input Photosensor

LBI-38976A. Mobile Communications MDX/ORION DESK TOP STATION. Operator's Manual

GTX 320A. Mode A/C Transponder. pilot s guide

CHECK LINE INSTRUMENTS. ! Tolerates a wide variation of voltages. ! Immune to electrically noisy environments.

Preliminary Data Sheet!

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Grid Radar Installation Manual

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

ProScale. Compact LCD Readout. Installation & Operation

ProScale Compact LCD Readout. Operation. Firmware version C 2.xxx and higher

Radio Remote Controls Manual K Series

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

9320 Manual Portable Battery Powered Indicator

Fits Tiger 320 Series UNIVERSAL FREQ/COUNTER INPUT MODULE

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Instruction Notes for 108A L Sensor Input

USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

PCO-7114 Laser Diode Driver Module Operation Manual

MS23SL Magnetic Linear Sensor With Smart Limit Switches

User s Guide TX92A. Miniature Temperature Transmitters. Shop online at omega.com

Warranty Terms & Conditions

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Instruction Manual Model M Switch, DPDT, Manual Select

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

SSR-150xxx-40VL-12P-xC-xxxCS

Table of Contents. Safety Notices

VT1586A Rack Mount Terminal Panel Installation and User s Manual

LT3000 ULTRASONIC LEVEL TRANSMITTER

E3X-DRT21/SRT21/CIF11

SA-027HQ 365-Day Annual Timer

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

SSR VL-12P-xC-NCS

Broadband Current Probe Series Operation Manual

American Power Design, Inc.

LPU-2127 User Manual

F4-08RTD 8-Channel RTD Input

PreView Plus Monitor. PVP710 Setup Guide.

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

TRANSDUCER IN-LINE AMPLIFIER

Global Water Instrumentation, Inc.

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver

Field Hub Installation Guide. P/N Rev. C 05/15

OWNER S MANUAL DANGER

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

WSA 8 BOX RELE Installation Manual

American Power Design, Inc.

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Single-phase Voltage Relay

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

Single-phase Current Relay

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

Signal Isolation Module. Instruction Manual SIM

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

INSTRUCTION MANUAL INF Fax: (503)

Staticmaster Model 6110 Air Assist Bar Ionizer

12B/18 MultiMeter Instruction Sheet

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

WORLD-BEAM QS30 Adjustable-Field Sensors

Phase-sequence Phase-loss Relay

American Power Design, Inc.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2

BATTERY SENSOR. User Manual. Manual Version: BMS

Firmware Version d & higher Installation & Operation

Sentry Digital Timers

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

Model Number Structure

TRANSDUCER IN-LINE AMPLIFIER

DIGITAL INTELLIGENT POWER FACTOR REGULATOR

COOLED InGaAS DETECTOR HEAD MODEL 71887

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

TABLE OF CONTENTS. Electromatic Equipment Co., Inc. -1-

Operating Instructions

Using the USB Output Port to Charge a Device

EC DECLARATION OF CONFORMITY

User s Guide CL309A Milliamp Loop Calibrator. Shop online at omega.com SM

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Digi-Stop. Installation & Operation

P.O. BOX 1521 POLSON, MT SSR V-12C

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Digi-Fence. User Manual (all models) For All Models with Digital Readout Firmware version d & Higher

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

Model Number Structure

User s Guide Instructions for Installation and Operation

4590 Tank Side Monitor. Service Manual. Mark/Space Communication Protocol. Software Version v2.03 SRM009FVAE0808

MWC2-9. Operation Manual. MWC MHz Receiver with FM Radio Option. Radio. manmwc29_v7

Transcription:

MODEL 8080R3 Released on 11 th Mar 2013

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 DESCRITION The IME 8080R3 is a micro-controller based Digital Dual-channel Indicator with two relay outputs having ON/OFF control output feature, offered in a highly compact, rugged and reliable execution. The instrument has three keys on the front panel, with which the operator can set the parameters and configure the instrument as desired. A four-digit red LED digital display is provided on the front panel which indicates the process temperature value in real time. The instrument has non-volatile memory (i.e., in case of power failure, the set points and other settings are retained in memory and the indication and control actions resume after power is restored). The instrument can accept a RTD t-100 and displays the temperature while providing ON/OFF control outputs. Set points are configured through the Membrane Keypad on the front panel. The temperature display is factory calibrated to the normal operating ranges of the respective temperature sensors through the instrument software and may be changed whenever desired. The instrument accepts any one of the following input signals: SR. NO. TEMERATURE SENSOR CALIBRATED RANGE C 1. RTD t-100 (three-wire) 70.0 to 500.0 The type of sensor input is selected during the instrument configuration (see SETTINGS section). The selected input signal is suitably isolated and conditioned by the micro-controller, which displays the actual temperature value in real time on the digital display. Two Relay outputs are included in this model each of which may be configured to operate on either Heating or Cooling setting, with its independent hysteresis value. These set-points are configured through the Membrane Keypad on the front panel [see Operation & Settings section]. The micro-controller based Dual channel Temperature Indicating Controller Model: 8080R3 is an ideal instrument for temperature measurement and control applications because of its versatility and inherent accuracy in process measurement and control. Other superior features are; total immunity to shocks, dust, ambient temperatures, and humidity. Additionally, the 8080R3 operates on 12 28 V DC. All I.M.E instruments are manufactured using selected high-grade components which guarantee functionality and long operational life. Our confidence in the products is stated in a performance guarantee against manufacturing and workmanship defects (see Warranty clause). INSTALLATION The device should be mounted so that it is secure and not subject to damage or excessive vibration [See Technical Specifications]. All interconnections to the instrument should be made with strong multi-strand wire of the order of 2.5 sq.mm. The ends of the wires should be properly ferruled and suitable lugs must be used for effective termination. The cables carrying the input (Sensor) signal should be routed separately and properly isolated from the power line cables and Control Relay wiring, to prevent any electromagnetic interference in the input signal readings from the main power line. Use of shielded twisted pair cable is recommended for input signals. The shield must be connected to Earth (Ground) only at the instrument end. The instrument should be earthed (grounded) to a proper grounding point before connecting the ower Supply. The voltage between the Earth (Ground) and Neutral terminals should be negligible (Approx. 1 V AC). The Relay contacts are potential free and any desired voltage may be used in conjunction with the same. All Relay Circuits shall be connected to same phase circuit only. INTERNATIONAL METAL ENGINEERING REV 6 02

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 INTERNATIONAL METAL ENGINEERING REV 6 03

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 OERATION AND SETTING The front panel of the Digital Temperature Indicator Controller is as shown below: The 8080R3 Digital Temperature Indicator Controller has a four-digit LED display window on the front panel for indicating the temperature value. Four other LED status indicators are displayed on the front panel two Yellow LEDs show the channel status, i.e., whether channel 1 or channel 2 is being displayed and two red LEDs indicate the status of each control Relays.. CONTROL KEYS The instrument has three keys on the front panel. The functions of these are described below: The or RAM key marked is the central co-ordinating key to access the settings of the instrument. ressing this Key allows the operator to sequentially view, change and save the parameters such as Sensor selection, Channel selection, Relay Set-points, Hysteresis, Control Logic, etc. INC The INC or Incrementing key allows the operator to select the numeral in the digit being set on an increasing scale. The digit will sequentially display 0, 1, 2.9 on each pressing of the INC key. This may be used to set the Zero/Span of the temperature range and the Set-points of the Relays. The incrementing speed increases if the key is kept pressed. DEC The DEC or Decrementing key allows the operator to select the numeral in the digit being set on a decreasing scale. The digit will sequentially display 9, 8, 7.0 on each pressing of the DEC key. This may be used to set the Zero/Span of the temperature range and the Set-points of the Relays. The decrementing speed increases if the key is kept pressed. INTERNATIONAL METAL ENGINEERING REV 6 04

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 CONTROL AND USER SETTINGS The following is the sequence of settings on the Digital Temperature Indicator / Controller. (NOTE that you do NOT require any Sensor or external Signal source to be connected to the instrument for Calibration or any instrument settings) CONTROL SETTINGS KEY RESSED INITIAL DISLAY Access Menu by ressing Button All settings to be done using INC ( ) and DEC ( ) keys. ALTERNATING DISLAY FUNCTION (OWER ON) 8.8.8.8. Initialization of internal controller and Lamp Test (self diagnostics). O E n If Input Sensor is not connected. actual temp If Input Sensor is connected. The Set-point Set1 for Relay-1 is displayed alternately St1 (preset value) with the factory preset value. The Set-point Set2 for Relay-2 is displayed alternately St2 (preset value) with the factory preset value. (process value) (if Sensor is connected) USER SETTINGS Access Menu by ressing & button All settings to be done using INC ( ) and DEC ( ) keys. KEY RESSED DISLAY ALTERNA TING DISLAY FUNCTION ress and hold INC( ) DEC( ) key for 2 seconds Instrument goes into User mode. SCLE CEnt SEn1 Г t d 1 SEn2 Г t d 1 IC1 0000 IC2 0000 Con1 H E t HY1 0001 dly1 0001 Set Temperature Scale. The options are : Cent ------- Degrees Centigrade FAГ ------- Degrees Fahrenheit The active Input Signal / Sensor of Channel 1 will be displayed on the upper display for three seconds. Г t d 1 ------- RTD t-100 sensor with one digit resolution Г t d.1 ------- RTD t-100 sensor with 0.1 digit resolution The active Input Signal / Sensor of Channel 2 will be displayed on the upper display for three seconds. Г t d 1 ------- RTD t-100 sensor with one digit resolution Г t d.1 ------- RTD t-100 sensor with 0.1 digit resolution Set the input correction which directly adds or subtracts from displayed reading if necessary. This is an offset count to the displayed value. You can set from -999 to 9999 counts. Set the input correction which directly adds or subtracts from display reading if necessary. This is an offset count to the displayed value. You can set from -999 to 9999 counts. Type of Control Action for Relay-1. Options are : HEt : Heating Logic COL : Cooling Logic Temperature Hysteresis: Adjust the desired Hysteresis in deg Celsius for Relay-1 using INC and DEC keys [e.g. 0001 for a hysteresis of 1 degree]. Time Hysteresis: Adjust the desired minimum off time (in seconds) between Relay-1 resets (to avoid chatter) using INC and DEC keys. [e.g. 0001 for a hysteresis of 1 second]. INTERNATIONAL METAL ENGINEERING REV 6 05

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 Con2 HEt HY2 0001 dly2 0001 St1 C H 1 St2 C H 2 MOdE togl St1 St2 (process value) (preset value) (preset value) Type of Control Action for Relay-2. Options are : HEt : Heating Logic COL : Cooling Logic OFF : For Single Relay Operation Temperature Hysteresis: Adjust the desired Hysteresis in deg Celsius for Relay-2 using INC and DEC keys [e.g. 0001 for a hysteresis of 1 degree]. Time Hysteresis: Adjust the desired minimum off time (in seconds) between Relay-2 resets (to avoid chatter) using INC and DEC keys. [e.g. 0001 for a hysteresis of 1 second]. Channel assign: The desired channel can be assign to first set point using INC and DEC keys. Channel assign: The desired channel can be assign to second set point using INC and DEC keys. Display Options are : togl : Toggle display between Channel 1 and Channel 2 every 8 seconds CH1 : Display Channel 1 only CH2 : Display Channel 2 only Adjust the desired Set-oint for Relay-1 using INC and DEC keys. The indication St1 which is the control set-point for Relay-1, is displayed alternately with the last preset value. Adjust the desired Set-oint for Relay-2 using INC and DEC keys. The indication St2 which is the control set-point for Relay-1, is displayed alternately with the last preset value. (if Input Signal is connected) ARAMETER OTIONS AND INDICATIONS 1 Escape function with saving parameters: ressing the program key for 5 seconds while in user setting mode will save any changes made and the display will revert to the process value. Also, scrolling through to the end of the menu until you return to the process value will save any changes made. 2 Escape function without saving parameters: ressing the INC ( ) and DEC ( ) keys simultaneously while in user setting mode will not save any changes made. The display will then revert to the process value or open if there s no connection. 3 Time out: If no key is pressed for a period of 30 seconds the device will come out of user setting mode WITHOUT SAVING ANY CHANGES MADE and revert to the process value. 4 Factory Reset: If operator press the Decrement ( ) key for 10 seconds, unit will return to factory settings. 5 Sensor fail indication: In the case of sensor failure, the display will show the process value of one channel and O E n for failed channel. This completes the entire settings of the Digital Temperature Indicator/ Controller. The explanation of the various Displays and Messages that would be visible on the instrument Menu are as follows:- SR. MESSAGE DESCRITION 1. Con1 / Con2 Set-oint for Relay-1/2. 2. HY1 / HY2 Hysteresis for Relay-1/2 [e.g. 0010 for a hysteresis of 10 degrees]. 3. dly1 / dly2 Time Hysteresis: To adjust the desired minimum off time (in seconds) between Relay resets (to avoid chatter). 5. HEt Heating Control Logic for Relay-1/2 6. COL Cooling Control Logic for Relay-1/2 7. Sen The active Input Temperature Sensor / Signal. Options include : Гtd 1 ------- RTD t-100 [three-wire] sensor 1 C Гtd. 1 ------- RTD t-100 [three-wire] sensor 0.1 C INTERNATIONAL METAL ENGINEERING REV 6 06

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 TERMINAL DIAGRAM FRONT VIEW REAR-VIEW 4 - digit display Temperature for Indication 8 7 6 5 RELAY 1 9 10 11 4 3 2 RELAY 2 12 13 14 1 TERMINAL BLOCK 1 (For RTD t-100 Sensor) 1 2 3 4 5 6 7 8 + + + 12-28V DC ower Supply RTD T-100 CH 2 RTD T-100 CH 1 TERMINAL BLOCK 2 9 10 11 12 13 14 NC C NO NC C NO RELAY 1 RELAY 2 TERMINAL DETAILS TERMINAL BLOCK TERMINAL BLOCK - 1 TERMINAL BLOCK - 2 TERMINAL NOTATION NO. 1 + 2 3 4 5 SEE SENSOR TABLE + 6 ALONGSIDE 7 8 + 9 NC 10 COM 11 NO 12 NC 13 COM 14 NO DETAILS ower Supply 12 to 28V DC RELAY 1 RELAY 2 RTD T-100 RTD T-100 INTERNATIONAL METAL ENGINEERING REV 6 07

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 TECHNICAL SECIFICATIONS Model : 8080R3 Type : Microcontroller based Digital Temperature Indicator with Control option No. of Channels : Two nos. of RTD Inputs Input Signal : RTD t-100 (three-wire) Display : Seven-segment, red LED display Indications : Four-digit temperature display Scale Range : -70 to 500 (RTD T-100) Calibration Range : May be calibrated as required Decimal point : reset depending on Sensor Response time : Typically 200 ms Output : Relay-1 with Heating/Cooling Relay-2 with Heating/Cooling Contact rating : 230VAC, 5A RESISTIVE; 24VDC, 5A RESISTIVE Memory : Non-Volatile (on EEROM) Settings : By Membrane Switchpad on front panel. Accuracy : 0.1% FS ower Consumption : 112mA at 12 V DC ower Supply : 12 to 28V DC Operating Temperature : -40 to 60 Degrees C INTERNATIONAL METAL ENGINEERING REV 6 08

DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 WARRANTY International Metal Engineering te. Ltd. (IME) for the effective period of the warranty set out below, warrants that its standard products will be free from defects in materials and workmanship under normal use and service. International Metal Engineering te Ltd. s obligation under this warranty shall not arise until Buyer returns the defective product, freight prepaid to IME s facility in Singapore or any other authorized destination, specified in writing by IME. The only responsibility of IME under this warranty is, at its option and sole discretion, to replace or repair, free of charge any defective component part of such product. EFFECTIVE ERIOD OF WARRANTY Three years from date of invoice for new products. For repairs the warranty shall be one year from the date of shipment. LIMITATION OF WARRANTY The warranty set forth herein does not extend to and shall not apply to: roducts which have been repaired or altered by other than IME s personnel, unless Buyer has properly altered or repaired the products in accordance with procedures previously approved in writing by IME. roducts, which have been subject to misuse, neglect, accident, or improper installation or operation. roducts, which have been mechanically damaged. The warranty and remedies set forth above are in lieu of all other warranties expressed or implied, oral or written, either in fact or by operation of law, statutory or otherwise, including warranties of merchantability and fitness for a particular purpose, which IME specifically disclaims. IME neither assumes nor recognizes any other liability in connection with the sales, installation or use of its products. IME shall have no liability for incidental or consequential damages of any kind arising out of the sale, installation or use of its product. The IME address to which notices, authorizations, and approvals and written communications pertaining to this warranty are to be delivered is: INTERNATIONAL METAL ENGINEERING TE. LTD. Blk 13 Toa ayoh Lorong 8 #06-05 Braddell Tech ark Singapore 319261 Tel. +65-6353-6506 Fax. +65-6353-6281 E-mail: admin@intmet.com lease refer to our website for other locations around the world.www.intmet.com 01 INTERNATIONAL METAL ENGINEERING REV 6 09