LPM Series INSTALLATION INSTRUCTIONS The Command Access Latch Pullback retracts the latch for push/pull operation. These instructions cover all series from LPM110-LPM188. LPM 72 WIRE HARNESS (3-PRONG) C. 72 WIRE HARNESS (3-PRONG) B. PM300 72 WIRE HARNESS (2-PRONG) C. 24 VDC Power Supply A. LPM Series Includes A. LPM B. PM300 C. 2- Power Leads U.S. Customer Support 1-888-622-2377 Visit our website for more details www.commandaccess.com 1 Canada Customer Support 1-855-823-3002 Doc # xxxxx rev.x
Standard Placement Module Ceiling Tile Hinge Option Only Module LPM1 Series Installation Example Standard Placement Optional Placement Note: For LPM1 series option placement is only recommended for Hollow metal doors. For wood doors, use standard placement above ceiling tile or in junction box. 1. The door must be prepared with a standard type 86 mortise lock preparation and a 3/8 wire raceway. Be sure that the mortise pocket and the raceway are clear of debris prior to installation. 2. Install the 3-prong, 72 wire harness through the wire raceway leaving enough slack to quick connect to the mortise chassis. 3. Install PM300 at the hinge jamb side of the door within 120 of the lockset. Connect the 3-prong wire harness to the PM300 and hard wire it directly to the harness from the lockset (if using an electric hinge or other transfer device, use 18ga wire). 4. Connect the 2-prong input power wires (BLACK and BLACK) of the PM300 to the 2-prong, 72 wire lead. Then connect the 72 wire lead directly to the wire run coming from the 26.5VDC power supply (not included). The power supply may be up to 300 feet away (see power supply wiring instructions). Note: these wires are not polarity sensitive. 2
For Lever Control Solenoid on LPM models 183-188 Only All other models skip to next page Step 1 - The door must be preped according to origional manufactures template, machined with a 3/8 wire raceway, & preped for a energy transfer hinge. Make sure the mortise pocket is free of debris. Step 4 - Connect the wires exiting the mortise pocket to the Bridge Rectifier (included). Bridge Rectifier ETH Hinge Step 5 - Connect the Bridge Rectifier to the plug exiting the mortise chassis. 3/8 Wire Raceway Bridge Rectifier Step 2 - Run the wires from the ETH hinge through the 3/8 raceway starting at the ETH hinge & exiting into the mortise pocket. Plug Step 6 - Carefully slip the connected mortise lock chassis into the mortise pocket paying close attention not to pinch any wires 3/8 Wire Raceway Wire Transfer Hinge Step 7 - Mount the chassis per manufacturer s instructions. Step 3 - Screw the ETH hinge to the door. At this time DO NOT connect the hinge wires on the jamb side to the wires coming from the power supply. Step 8 - Connect the wires from the power supply at the ETH hinge on the jamb side. Connect the hinge to the jamb. EU (Fail Secure) Bridge Rectifier Energy Transfer Hinge Switch EU (Fail Secure) 12VAC/DC or 24VAC/DC Power Supply EL (Fail Safe) Bridge Rectifier Energy Transfer Hinge Switch EL (Fail Safe) 12VAC/DC or 24VAC/DC Power Supply 3
Handing Instructions for LPM STEP 1: Locate the handing screw. This screw is used to hand the handles. The ing side is opposite the screw. LH/LHR STEP 2: To hand the latchbolt, remove the faceplate. Pull the latchbolt out of the chassis and rotate, then release. The latchbolt is spring loaded and will return on it s own. RH/RHR Rotate 180 Deg. Handing Screw Template for non-deadbolt & deadbolt 1-1/4 diameter cylinder hole for exterior side only (Optional for deadbolt function) 5/8 diameter thumb turn hole for interior side only 3/8 diameter 1 diameter 3/8 diameter 2-7/32 2-3/4 3-9/32 4-7/16 2-9/64 1 1-3/16 1-23/32 2-1/4 6-1/8 4
Latch Retraction Operating Voltage Range: 24 VDC +/- 10% Hold Current: 260 ma @ 24 VDC Surge Current: 1.6 A for 350 ms @ 24 VDC Peak Current: 7 A @ 24 VDC Input wires to PM300 : Non-polarized Black (+)(-) TECHNICAL INFORMATION Specifications Output wire from PM300: Yellow=Pull Coil; Orange= Hold Coil; Green=Common Lever Control Operating Voltage Range: Switches 24VAC/DC 350mA 12VAC/DC 700mA REX: Green - Common (C) Blue - Normally Open (NO) Gray - Normally Closed (NC) LBM: Green/Black - Common (C) Blue/Black - Normally Open (NO) Gray/Black - Normally Closed (NC) Wire Run Guidelines: For best results we recommend that your maximum wire run not exceed the following: 18ga.= 700 16ga. = 1000 14ga. = 1250 12ga. = 1500. Power Supply for PM300 and PM300D in High Output Mode: In High Output mode, the PM300 is designed for & MUST BE powered by the Command Access PS1, PS5-4, or PS5-6 power supplies only. Troubleshooting & Diagnostics Check the Module is on High Output. Confirm that power supply is a Command Access PS1, PS5-4, or PS5-6 U.S. Customer Support 1-888-622-2377 Visit our website for more details www.commandaccess.com 5 Canada Customer Support 1-855-823-3002 Doc # xxxxx rev.x