LPM Series INSTALLATION INSTRUCTIONS. instructions cover all series from LPM110-LPM WIRE HARNESS (3-PRONG) PM300. LPM Series Includes

Similar documents
Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Installing Your Electronic Deadbolt

8500 Series. The fire-rated, concealed electric strike solution for mortise locksets. Available At. Click Here FOLGER ADAM HES INTEGRATED PRODUCTS

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Certification Exhibit FCC ID: U4A-SCYPROX2 IC: 6982A-SCYPROX2. FCC Rule Part: IC Radio Standards Specification: RSS-210

HES Series Electric Strikes & Optional faceplates 1006 Grade 1 electric StrikeS series optional faceplates AD: E Option

Installation Instructions

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Installation Instructions

Installation Instructions for 45H & 47H Mortise Locks

1006CLB 12VDC or 24VDC Fail secure 12V-45mA, 24V-25mA

The strongest, most versatile electric strike available

SERIES 6000 ELECTRIC STRIKES

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

For New or Retrofit Construction Retrofits Existing ANSI 4-7/8 Strike Prep No Centerline Relocation

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

DB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options

Installation Instructions For The 8850FL Series Mortise eboss

The strongest, most versatile electric strike available

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number:

Steel Hawk 4300 Electrified Deadlatch (elatch)

Installation & Programming Guide

TRILENNIUM FULL SCOPE (FS) TEMPLATE INSTRUCTIONS

Entry Mortise Handleset

Installation Instructions

Entry Mortise Lock Set Lever to Lever

NM SERIES. Extra Heavy Duty Mortise Locks Grade 1

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

98/ Customer Service # Dogging Key (use to lock down pushbar)

Electric Strike Complete with LB option includes faceplates that accommodate J, K, KM or KD options

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR HIT TEMPLATE FOR SALTO XS-4 MORTISE & CYLINDRICAL LOCKS

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

Headline. Push/Pull Latches

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

1006 Series + = Non-handed Trim adapter (goof plate) 5 year limited warranty

PMR ELECTRONIC LOCK USER GUIDE

Electric Strikes. Overview

Passage Mortise Lock Set Lever to Lever

Headline Push/Pull Latches

Door Hardware Installation Instructions. For Assistance Call:

E-PLEX 3X00 SERIES NARROW STILE LOCK INSTALLATION INSTRUCTIONS

CATALOG PRICELIST HES ELECTRIC STRIKES AND ACCESSORIES 2011 HES AND FOLGER ADAM ELECTRIC STRIKES AND ACCESSORIES

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Exit Device 5820 SERIES GRADE 1 PUSH BAR SPECIFICATIONS HEAD COVER OPTIONS STRIKES APPLICATION.

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

Installation Instructions For Profile Series v.g1 Exit Device

M O R T I S E L O C K S

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment

Series. The strongest, most versatile electric strike available FOLGER ADAM HES INTEGRATED PRODUCTS. Specifications

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

WNA Series. Knobsets AVAILABLE STYLES AVAILABLE FINISHES. Finish A 26 26D 34 3W BEVERLY HUNTINGTON PHOENIX TROY BHMA Code

DOOR TECHNOLOGY ORDER CATALOG SECTION SECURY Automatic Door Lock & Gripset Handle

MEETS ADA REQUIREMENTS!

This is a printable pdf document. For Smartphone-friendly version, tap or click here.

DIVISION 8 DOORS AND WINDOWS. 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum.

Concealed Shallow tab 17.3 (.68) 11 (.44) 86 (3.38) 44 (1.72) 8 (5/16) Hex wrench opening (.252) 2 PL. Receptacle panel. Latch. panel Ø13 (.

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Travel Trailer Latch With Dead Bolt Trailer Latch With Dead Bolt. U.S. Patent No. 5,927,773

10027 S. 51st Street, Ste 102 Phoenix, Arizona (800) Fax:(800)

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

Installation Instructions ENGLISH

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Chapter 9. Windows and Exterior Doors

4000 Series. The Gainsborough 4000 Series Heavy Duty Cylindrical Locksets KEY IN KNOB LOCKSETS

Series. The heavy duty, low profile solution for latchbolts. The 1500 Series is also available in a Complete One Box Solution FOLGER ADAM HES

Tools Required. * When installing on a fire door, please see instructions below. *

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Series. The dynamic, low profile solution for latchbolts and deadbolts Models. The 1600 Series is also available in a Complete One Box Solution

Adams rite. Electric Strikes for exit device, deadlatch or lockset

1. Begin by rolling your window up all the way 2. Remove your door and window handles by unscrewing the flat head set screws behind each handle.

6200 Series. System Components Series Electric Strikes

Series. The heavy duty, low profile solution for latchbolts. The 1500 Series is also available in a Complete One Box Solution FOLGER ADAM HES

FLUSHLINE ENTRANCES. Features

INSTRUCTIONS FOR HIT TEMPLATE FOR ALARM LOCK DL3500 MORTISE LOCK

S O L I D B R O N Z E H A R D W A R E the beauty of fine design, the eternity of solid bronze V E N E T O SOLID BRONZE

World s Leading Manufacturer Of Traffic Doors. Supplemental Instructions for the Single and Double Door Order Form

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Finish Hardware. Contents. Section 10

Victory Fire Door Inspections

SERIES. Installation Instructions

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

PHYSICAL FACILITIES Consultant s Handbook Division 08 Openings 7400 Access Control Hardware. Page 1 of 6

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTRUCTIONS FOR HIT TEMPLATE FOR BEST 34H-37H MORTISE LOCK

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

SCHLAGE SENSE. Smart Deadbolt. Installation Instructions. Download the Schlage Sense app to get started!

Installation Instructions

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

Your combination is and is not recorded at the factory. This number can be found on the combination slides if required.

DOOR SAVERS AVAILABLE IN STEEL, STAINLESS STEEL (32D), BRIGHT BRASS (3), BRONZE (10) AND OIL RUBBED BRONZE (10B)

Transcription:

LPM Series INSTALLATION INSTRUCTIONS The Command Access Latch Pullback retracts the latch for push/pull operation. These instructions cover all series from LPM110-LPM188. LPM 72 WIRE HARNESS (3-PRONG) C. 72 WIRE HARNESS (3-PRONG) B. PM300 72 WIRE HARNESS (2-PRONG) C. 24 VDC Power Supply A. LPM Series Includes A. LPM B. PM300 C. 2- Power Leads U.S. Customer Support 1-888-622-2377 Visit our website for more details www.commandaccess.com 1 Canada Customer Support 1-855-823-3002 Doc # xxxxx rev.x

Standard Placement Module Ceiling Tile Hinge Option Only Module LPM1 Series Installation Example Standard Placement Optional Placement Note: For LPM1 series option placement is only recommended for Hollow metal doors. For wood doors, use standard placement above ceiling tile or in junction box. 1. The door must be prepared with a standard type 86 mortise lock preparation and a 3/8 wire raceway. Be sure that the mortise pocket and the raceway are clear of debris prior to installation. 2. Install the 3-prong, 72 wire harness through the wire raceway leaving enough slack to quick connect to the mortise chassis. 3. Install PM300 at the hinge jamb side of the door within 120 of the lockset. Connect the 3-prong wire harness to the PM300 and hard wire it directly to the harness from the lockset (if using an electric hinge or other transfer device, use 18ga wire). 4. Connect the 2-prong input power wires (BLACK and BLACK) of the PM300 to the 2-prong, 72 wire lead. Then connect the 72 wire lead directly to the wire run coming from the 26.5VDC power supply (not included). The power supply may be up to 300 feet away (see power supply wiring instructions). Note: these wires are not polarity sensitive. 2

For Lever Control Solenoid on LPM models 183-188 Only All other models skip to next page Step 1 - The door must be preped according to origional manufactures template, machined with a 3/8 wire raceway, & preped for a energy transfer hinge. Make sure the mortise pocket is free of debris. Step 4 - Connect the wires exiting the mortise pocket to the Bridge Rectifier (included). Bridge Rectifier ETH Hinge Step 5 - Connect the Bridge Rectifier to the plug exiting the mortise chassis. 3/8 Wire Raceway Bridge Rectifier Step 2 - Run the wires from the ETH hinge through the 3/8 raceway starting at the ETH hinge & exiting into the mortise pocket. Plug Step 6 - Carefully slip the connected mortise lock chassis into the mortise pocket paying close attention not to pinch any wires 3/8 Wire Raceway Wire Transfer Hinge Step 7 - Mount the chassis per manufacturer s instructions. Step 3 - Screw the ETH hinge to the door. At this time DO NOT connect the hinge wires on the jamb side to the wires coming from the power supply. Step 8 - Connect the wires from the power supply at the ETH hinge on the jamb side. Connect the hinge to the jamb. EU (Fail Secure) Bridge Rectifier Energy Transfer Hinge Switch EU (Fail Secure) 12VAC/DC or 24VAC/DC Power Supply EL (Fail Safe) Bridge Rectifier Energy Transfer Hinge Switch EL (Fail Safe) 12VAC/DC or 24VAC/DC Power Supply 3

Handing Instructions for LPM STEP 1: Locate the handing screw. This screw is used to hand the handles. The ing side is opposite the screw. LH/LHR STEP 2: To hand the latchbolt, remove the faceplate. Pull the latchbolt out of the chassis and rotate, then release. The latchbolt is spring loaded and will return on it s own. RH/RHR Rotate 180 Deg. Handing Screw Template for non-deadbolt & deadbolt 1-1/4 diameter cylinder hole for exterior side only (Optional for deadbolt function) 5/8 diameter thumb turn hole for interior side only 3/8 diameter 1 diameter 3/8 diameter 2-7/32 2-3/4 3-9/32 4-7/16 2-9/64 1 1-3/16 1-23/32 2-1/4 6-1/8 4

Latch Retraction Operating Voltage Range: 24 VDC +/- 10% Hold Current: 260 ma @ 24 VDC Surge Current: 1.6 A for 350 ms @ 24 VDC Peak Current: 7 A @ 24 VDC Input wires to PM300 : Non-polarized Black (+)(-) TECHNICAL INFORMATION Specifications Output wire from PM300: Yellow=Pull Coil; Orange= Hold Coil; Green=Common Lever Control Operating Voltage Range: Switches 24VAC/DC 350mA 12VAC/DC 700mA REX: Green - Common (C) Blue - Normally Open (NO) Gray - Normally Closed (NC) LBM: Green/Black - Common (C) Blue/Black - Normally Open (NO) Gray/Black - Normally Closed (NC) Wire Run Guidelines: For best results we recommend that your maximum wire run not exceed the following: 18ga.= 700 16ga. = 1000 14ga. = 1250 12ga. = 1500. Power Supply for PM300 and PM300D in High Output Mode: In High Output mode, the PM300 is designed for & MUST BE powered by the Command Access PS1, PS5-4, or PS5-6 power supplies only. Troubleshooting & Diagnostics Check the Module is on High Output. Confirm that power supply is a Command Access PS1, PS5-4, or PS5-6 U.S. Customer Support 1-888-622-2377 Visit our website for more details www.commandaccess.com 5 Canada Customer Support 1-855-823-3002 Doc # xxxxx rev.x