Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Similar documents
Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

SALES SERVICE +358 (0)

Positioner with HART Communication Type 3780

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

KFS. Flap-type flow meter. Design and range of application

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Inductive sensor slot-type SI2-K08-AP7

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Design and applications

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

KINAX SR 719 Programmable Transmitter for Position Feedback

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Pressure transmitter AKS 32 and AKS 33

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Explosion proof rotary actuator - On/Off or programmable regulating actuator

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

IP26 Series Current to Pneumatic Converter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

Electronically controlled proportional pressure regulating valves

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Type CP-S, CP-C & CP-A Switch mode

Temperature Input Module for Zone 1 Series 9482/32

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Field indicator for current loops with HART communication Models DIH50, DIH52

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

Electronic Pressure Switch Type MEP

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Resistance thermometer Model TR31, miniature design

Safety switches with slotted hole lever

Target disk flowmeter for liquids and gases

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Digital flow ELEMENT transmitter for continuous flow measurement

Metal tube variable area flowmeters for gases, liquids and steam

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

itemp HART DIN rail TMT112

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Fisher 646 Electro Pneumatic Transducer

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Miniature resistance thermometer Model TR33, thread-mounted

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

INLINE flowmeter for continuous flow measurement

Power consumption Operation At rest Wire sizing

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure Transmitter SIL

Sturdy explosion proof housing and smart performance with innovative and ever-strong coil drive even under harsh working environments

Pressure transmitter for general industrial applications Model A-10

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

PHOENIX CONTACT - 09/2009

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Power consumption In operation At rest For wire sizing

Direct Operated Proportional DC Valve Series D1FP

Technical data sheet. Technical data. Safety notes

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Pressure transmitter for general industrial applications Model A-10

Proportional Directional Control Valves Nominal sizes 16 and 25

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Temperature transmitter itemp PCP DIN rail TMT 121

INLINE flowmeter for continuous flow measurement

Power consumption In operation At rest For wire sizing

Resistance thermometer Model TR30, compact design

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Flush pressure transmitter For viscous and solids-containing media Model S-11

SITRANS T measuring instruments for temperature

PSR-SCP- 24DC/ESD/5X1/1X2/300

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Pressure transmitter For sanitary applications Model SA-11

M70LL Laser Distance Sensor

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Datasheet - PROTECT-IE-02

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

ENCODER. Analog Multiturn Encoder. Serie 8.M5861. Key-Features:

Technical data. Safety notes

NGR. Guided Wave Radar Level Transmitter

Rotary gear motor series AG8...

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

FOR RELIABLY MEASURING +

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Transcription:

General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845 Angle of rotation 90 Aluminium cast / plastic Degree of protection IP 54 Installation position Any installation position possible Climate class Operation 4K3, but -20... +80 C, low temperature execution -40... +80 C Storage 1K5, but -40... +80 C Vibration resistance CE marking Transport Controller data Gain max. 100 2K4, but -40... +80 C < 10 g acc. to DIN 89011 Recommended continuous range for complete fittings 3 g Compliant with EG-EMV-rules 2014/30/EU and EC machinery rule 2006/24/EG Hysteresis Response level Unlinearity Supply air influence < 0,7 % of the control range < 0,5 % of the control range < 2 % of the control range < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar Dimensions See dimensional drawings figure 1 and 2 Weight Type 824.P Approx. 1,8 kg Type 824.E Pressure gauge block Approx. 2,0 kg Approx. 0,5 kg Connections Electric In dependence of version 0 to 2 cable inlets M20 x 1,5 Pneumatic with external pipe Pneumatic with internal pipe Y and Z: collateral G ¼ DIN 45141, special version ¼ NPT Z: collateral G ¼ DIN 45141, Y: behind G 1/8 TD-824_gb_05-2017 - subject to technical modifications - Page 1 of 8

Pneumatic data Inlet air pressure Air quality Air consumption Flow rate Solids Dew point 1,4...6 barg ISO 8573-1 Class 2 (particle size 1 μm, particle density 10 mg/nm 3 ) ISO 8573-1 Class 2 (- 40 C, min. 20 K below ambient temperature, low temperature execution < - 50 C) Oil content ISO 8573-1 Class 2 ( 0,1 mg/nm 3 ) < 0,6 Nm 3 /h, type 824.P < 0,5 Nm 3 /h during stationary operation 6 Nm 3 /h at 1,4 barg Electrical / pneumatic data basic device Electrical connection Pneumatic Not explosion-proof Figure 3 Input signal 0,2... 1 bar 0 / 4... 20 ma Split ranges 0,2... 0,6... 1 bar 0 / 4... 10 / 12... 20 ma Load resistance Required load voltage 170 Ώ 3,4 V _gb_05-2017 - subject to technical modifications - Page 2 of 8

Electrical data options inductive limit switches Version 824.P... 824.E... Limit switch N 824. - 1 Normal version 2 wire connection to DIN 19234 (NAMUR), for connected switching amplifier 2 slot initiators Type SJ3,5-N Function Break contact (NC, normally closed) Hysteresis 1 % Control loop See connected switching amplifier EMC acc. to EN 60947-5-2 and DIN 19234 Electrical connection Figure 4 Limit switch SN 824. - 2 Safety version 2 wire connection to DIN 19234 (NAMUR) for connected switching amplifier in safety version 2 slot initiators Type SJ3,5-SN Function Break contact (NC, normally closed) Hysteresis 1 % Control loop See connected switching amplifier EMC acc. to EN 60947-5-2 and DIN 19234 Electrical connection Figure 4 Limit switch E2 824. - 3 Direct switching version 3 wire connection with integrated switching amplifier 2 slot initiators Type SB3,5-E2 Function Make contact (NO, normally open) Hysteresis 1 % Supply voltage 10...30 V DC Max. load current 100 ma Electrical connection Figure 5 TD-824_gb_05-2017 - subject to technical modifications - Page 3 of 8

Electrical data options potentiometer and position feedback Version 824.P... 824.E... Potentiometer 824. - 2 Resistance 200, 500 or 1000 Ohm Deviation of characteristic 2 % Internal capacitance Ci 3,5 pf Internal inductance Li 10 H Electrical connection Figure 6 Position transmitter 3w 824. - 3 3 wire connection RWG, type 4522 Supply voltage 15...24 V DC Output 4(0) - 20 ma, short-circuit resistant Current limitation at ca. 28 ma Load resistance Ri 0-400 Ohm Deviation of 2 % characteristic Electrical connection Figure 7 Position transmitter 2w 824. - 4 2 wire connection RWG, type TMT 136R Supply voltage 8,5... 36 V DC Output 4-20 ma, short-circuit resistant Current limitation at ca. 36 ma Load resistance Ri 1300 Ohm at 36 V DC Deviation of 2 % characteristic Electrical connection Figure 8 Valid ambient temperature at other loops on request. Special version to - 40 C (dew point < -50 C). Special version NPT ¼. Adjustment of zero point and range at receiver terminal. Deviation of characteristic depends on mounting and stroke, max. 5 %. _gb_05-2017 - subject to technical modifications - Page 4 of 8

Figure 1 Dimensional drawing basic device type 824.P and 824.E Figure 2 Dimensional drawing pressure gauge block _gb_05-2017 - subject to technical modifications - Page 5 of 8

4 20 ma Figure 3 Electrical connection signal input basic device, type 824.E Figure 4 Electrical connection 2 wire limit switch (N and SN) Figure 5 Electrical connection 3 wire limit switch (E2) Figure 6 Electrical connection feedback potentiometer _gb_05-2017 - subject to technical modifications - Page 6 of 8

Figure 7 Electrical connection 3 wire position transmitter Figure 8 Electrical connection 2 wire position transmitter TD-824_gb_05-2017 - subject to technical modifications - Page 7 of 8

Order keys 8 2 4. P 0 0 0-0 0 0 Blocking and 0 without feedback 1./. 2 Potentiometer 3 Position transmitter 3 wire 4 Position transmitter 2 wire Limit switches 0 without 1 inductive normal version SJ3,5-N 2 inductive safety version SJ3,5-SN 3 inductive direct switching SB3,5-E2 Pneumatic 0 without extra equipment 1 pressure gauge block For linear stroke / 0 Stroke 20mm quarter turn 1 Stroke < 20mm 3 Angle of rotation 90 4 Angle of rotation 60 Input signal 0 0,2-1,0 bar 1 4-20 ma 2 0-20 ma 3 0,2-0,6 bar 4 0,6-1,0 bar 5 4-12 ma 6 12-20 ma 7 0-10 ma 8 10-20 ma Output signal 1 single acting 2 double acting Series Operating mode P pneumatic E electro-pneumatic, not explosion-proof _gb_05-2017 - subject to technical modifications - Page 8 of 8