SELF-QUENCHED SUPER-REGENERATIVE DETECTOR FOR NUCLEAR MAGNETIC RESONANCE BY a SURYAN SUMMARY 1. INTRODUCTION

Similar documents
By Richard H. Sands Department of Physics, University of Michigan, 4nn Arbor, Mich.

PHY3902 PHY3904. Nuclear magnetic resonance Laboratory Protocol

NMR Basics. Lecture 2

Pulsed NMR Experiment Guide Kenneth Jackson Physics 173, Spring 2014 Professor Tsai

In an unmagnetized piece of iron, the atoms are arranged in domains. In each domain the atoms are aligned, but the domains themselves are random.

Radar. Radio. Electronics. Television. .104f 4E011 UNITED ELECTRONICS LABORATORIES LOUISVILLE

Electromagnetic Induction - A

Lab 1. Resonance and Wireless Energy Transfer Physics Enhancement Programme Department of Physics, Hong Kong Baptist University

describe sound as the transmission of energy via longitudinal pressure waves;

A. ABSORPTION OF X = 4880 A LASER BEAM BY ARGON IONS

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

24.3 Production of Electromagnetic Waves *

High Voltage Generation

I p = V s = N s I s V p N p

PRINCIPLES OF RADAR. By Members of the Staff of the Radar School Massachusetts Institute of Technology. Third Edition by J.

Intermediate Physics PHYS102

Chapter Moving Charges and Magnetism

PULSED/CW NUCLEAR MAGNETIC RESONANCE

Chapter 33. Alternating Current Circuits

Analysis of magnetic and electromagnetic field emissions produced by a MRI device

Physics: Waves, Sound/Light, Electromagnetic Waves, Magnetism, Mains Electricity and the National Grid

Power System Dynamics and Control Prof. A. M. Kulkarni Department of Electrical Engineering Indian institute of Technology, Bombay

UNITED STATES PATENT OFFICE

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

MAGNETIC RESONANCE IMAGING

Type of loads Active load torque: - Passive load torque :-

Laboratory Exercise 6 THE OSCILLOSCOPE

1 Introduction. 2 The basic principles of NMR

Lab 12 Microwave Optics.

EXP 9 ESR (Electron Spin Resonance)

THE SINUSOIDAL WAVEFORM

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

Figure Cutaway view of the Phasitron tube, which is used as the modulator and upon which the operation of the GE f-m transmitter is based.

Navy Electricity and Electronics Training Series

CHAPTER 5 CONCEPTS OF ALTERNATING CURRENT

General Physics (PHY 2140)

WHOLE BODY L-BAND RESONATOR WITH A WIDE RANGE FREQUENCY TUNING USING PIEZO ACTUATOR

CHAPTER 8: ELECTROMAGNETISM

Chapt ha e pt r e r 11 Inductors

Development of a new Q-meter module

Advanced electromagnetism and electromagnetic induction

Chapter 21. Alternating Current Circuits and Electromagnetic Waves

Manufacturing Process - I Dr. D. K. Dwivedi Department of Mechanical and Industrial Engineering Indian Institute of Technology, Roorkee

CHAPTER 3 OSCILOSCOPE AND SIGNAL CONDITIONING

Name: Lab Partner: Section: The purpose of this lab is to study induction. Faraday s law of induction and Lenz s law will be explored. B = B A (8.

Magnetron. Physical construction of a magnetron

Lab 2 Radio-frequency Coils and Construction

THE INSTRUMENT. I. Introduction

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

Electromagnetism - Grade 11

Questions on Electromagnetism

Bryn Mawr College Department of Physics Undergraduate Teaching Laboratories Electron Spin Resonance

PHYS 1444 Section 501 Lecture #20

ANTICOINCIDENCE LOW LEVEL COUNTING

EXPERIMENT 12 PHYSICS 250 TRANSDUCERS: TIME RESPONSE

Nuclear Magnetic Resonance (NMR)

Figure 0 No Magnetic Field

Review of Progress in Quantitative Nondestructive Evaluation, Vol. 14 Edited by D.O. Thompson and D.E. Chimenti, Plenum Press, New Yorlc,l99S 1749

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

... frequency, f speed, v......

VARIABLE INDUCTANCE TRANSDUCER

AC Measurement of Magnetic Susceptibility

PHYS 1441 Section 001 Lecture #22 Wednesday, Nov. 29, 2017

Experimental setup to perform ferromagnetic resonance studies at the Modern Physics Laboratory

High frequency sounds, beyond the range of human hearing, are called ultrasound.

JEDI. Status of the commissioning of the waveguide RF Wien Filter

A Conceptual Tour of Pulsed NMR*

DIATHERMY UNITS HIGH FREQUENCY HEAT THERAPY:

NATIONAL. rfr1. Radio.Trician. Lesson Text No. 13. (2nd Edition) RADIO FREQUENCY AMPLIFICATION

Definitions. Spectrum Analyzer

System Inputs, Physical Modeling, and Time & Frequency Domains

DESIGN, CONSTRUCTION, AND THE TESTING OF AN ELECTRIC MONOCHORD WITH A TWO-DIMENSIONAL MAGNETIC PICKUP. Michael Dickerson

In this lecture. Electromagnetism. Electromagnetism. Oersted s Experiment. Electricity & magnetism are different aspects of the same basic phenomenon:

Introduction 1. The Experimental Method

Homebrew and Experimenters Group HF Inductance Bridge (Compiled by VK2TOX)

Welding Transformer: Principle, Requirement and Types

The Hirst GM04 Handheld Gaussmeter

15. the power factor of an a.c circuit is.5 what will be the phase difference between voltage and current in this

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

SUPPLEMENTARY INFORMATION

Television and video engineering

Chapter 18 The Electromagnetic Spectrum

An induced emf is the negative of a changing magnetic field. Similarly, a self-induced emf would be found by

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique

Physics 4C Chabot College Scott Hildreth

Experiment 12: Microwaves

UNIT-3. Electronic Measurements & Instrumentation

ESO 210 Introduction to Electrical Engineering

College Physics B - PHY2054C. Transformers & Electromagnetic Waves 10/08/2014. My Office Hours: Tuesday 10:00 AM - Noon 206 Keen Building

Technical Report M-TR91

[4] (b) Fig. 6.1 shows a loudspeaker fixed near the end of a tube of length 0.6 m. tube m 0.4 m 0.6 m. Fig. 6.

RADIO AMATEUR EXAM GENERAL CLASS

Design and Construction of a150kv/300a/1µs Blumlein Pulser

National 4. Waves and Radiation. Summary Notes. Name:

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Chapter 6: Power Amplifiers

PULSED NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

Transcription:

SELF-QUENCHED SUPER-REGENERATIVE DETECTOR FOR NUCLEAR MAGNETIC RESONANCE BY a SURYAN (From the Department of Physics, Indian Institute of Science, Bangalore) SUMMARY The self-quenched super-regenerator has been used to obtain nuclear magnetic resonance signals and has been found to be simple and sensitive. Experiments with the use of a r.f. coil capable of being rotated with respect to the magnetic field have indicated that the apparatus could be made to respond to induction or absorption. The sensitivity of the apparatus has been determined and is about ten times less than ultimate possible with the bridge method. 1. INTRODUCTION There are several methods of observing the phenomenon of nuclear magnetic resonance. They are (a) the absorption bridge method (Bloembergen, Pound, Purcell, 1948), (b) the nuclear induction method (Bloch, 1946), (c) the super-regenerative method (Roberts, 1947), (d) the regenerative oscillator method (Roberts, 1947) and (e) the pulse method (Torrey, 1949). The first two offer the ultimate signal to noise ratio and sensitivity. The next two are by far the simplest. The super-regenerative oscillator has a simpler version, namely, the self-quenching type. This, however, is not a mere variation of the super-regenerator, for it has many advantages of its own. Apart from the simplicity, the particular quench wave form generated by self-quenching is best suited for high sensitivity. These considerations made an investigation of the use of the self-quenched super-regenerator for observing nuclear magnetic resonance desirable and in what follows the results of the investigation are set forth. 2. THE APPARATUS A familiar self-quenching circuit has been chosen. Here the selfquenching is performed by the large grid leak resistance. The circuit is shown in Fig. 1. The circuit functions at all radio frequencies and has been The quench frequency is 20 Kcis. The used at frequencies above 1 Mc/s. oscillator coil is wound on glass forms and is capable of being placed along with its shield within the gap of the electromagnet. The magnet polepieces are of the truncated pyramid type and have a pole face area 3cx 25

26 G. SURYAN R.0 SELF QUENCHING SUPER-REGENERATOR FIG. I The main exciting coils are of thin wire and at a current of 1.5 amperes through them, a field of 6000 oersteds can be obtained in the i" air gap. An extra pair of coils are provided on the magnet limbs through which a 60 cycle alternating current of magnitude 1 to 3 amperes can be sent by means of a transformer. The magnetic field can be stabilized to a very high degree of stability by a simple method described by the author elsewhere (Suryan. 1952). The audio output of the super-regenerator is fed to a Cossor cathode-ray oscillograph whose linear sweep is synchronized with the mains frequency. The sample under investigation is placed inside the r.f. coil. With the alternating current suitable to give 10 oersteds sweep, it is easy to locate the resonance as the magnetic field is varied by means of a rheostat because one sees a train of waves pass the screen of the oscillograph on passing through resonance. 3. OPERATION It is estimated that the noise-muting sensitivity of the super-regenerator is of the order of 10 p.v. This is particularly of importance when the appa-

Self-Quenched Super-Regenerative Detector catus is used to respond to very small signals under nuclear induction conditions. Under all conditions of operation the oscillator functions coherently. Otherwise, the analysis of the oscillations into a fundamental and a number of side band frequencies is of no meaning. The oscillator is most sensitive when it is just coherently oscillating. The super-regenerator can respond to both nuclear induction and absorption. Roberts who was the first to suggest the use of a super-regenerator for observing nuclear magnetic resonance mentions that his apparatus respond to nuclear induction effect a voltage being induced in the r.f. coil by the precessing nuclei. On the other hand, Williams and Zimmerman mention that their super-regenerator responded to absorption of radio frequency energy. In the present investigation experiments have been performed to know the particular mode of operation. It will be recalled that the nuclear induction and absorption effects behave differently with respect to r.f. power level. Absorption effects are pronounced only at small power levels and saturation of the sample sets in at higher power levels. Induction, on the other hand, approaches a maximum as the power level is increased. Therefore it was decided to vary the power level of operation, or to be more precise the effective r.f. magnetic field was varied to find whether the signal varied accordingly. It is inconvenient to vary the power level of the oscillator by adjusting the plate supply voltage because that by itself changes the mode of operation and sensitivity. Therefore the following arrangement was adopted. The ref. coil was wound on a small glass tube and the substance was placed inside it in a thin-walled glass bulb. The coil had its end faces vertical and the coil could be rotated about a vertical axis so as to set the axis of the coil at any desired angle with respect to the direction of the magnetic field. It will be noted that only one rotating component of the plane polarized r.f. field is effective in stimulating absorption or emission by precessing nuclei in a magnetic field. The amplitude of the effective circularly polarized component is given by half the transverse component of the plane polarized r.f magnetic field in the coil, the component along the magnetic field is ineffective. Thus on rotating the coil from the transverse to the longitudinal position the effective r.f. magnetic field varies as cos 0,0 being the angle of inclination of the coil axis to the transverse direction and it varies from zero to a maximum determined by the operating conditions. The signal which is dependent on the effective r.f. magnetic field varies as the coil is rotated. The curve in 2 (a) shows the variation when the plate voltage was low and the quenching was just insufficient to stop the oscillations, where nuclear resonance absorption was prominent. It is seen that the curve shows a 27

28 maximum and then falls off, power level is optimum. On G. SURYAN the maximumn thc other hand, occurring where the effective the curve 2 (b) obtained with FIG. 2 higher plate voltage and quenching more pronounced, is differmt and shows a steady decrease with fall in r.f. field. Also it must be remembered that while the absorption effect depends on the effective power level, induction involves cos 6 as the induced voltage in the coil due to precession will be proportionately smaller because of the inclination of the coil. Thus the type of a nuclear resonance signal obtained in the super-regenerator can be found. Also this experiment shows that only the magnetic field component of the R.F. is responsible for stimulating nuclear magnetic resonance. In order to convey an idea of the overall sensitivity, one set of data of signal vs. quantity of substance has been presented in Fig. 3. It is found that the response is not linear and the smallest quantity of water in which proton signals have been observed with an overall signal noise ratio equal to 4, at 1500 oersteds is 1/20 c.c. For comparison the ultimate signal noise ratio for 1/20 c.c. of water can be calculated for the band widths employed by means of Pound, Purcell, and Bloernbergen's (1948) formula. It comes to be 25. That is, the present arrangement has perhaps an overall signal

Self-Quenched Super-Regenerative Detector 2) JO 20 v e 0.4 0.6 0.0 1 0 1-2 Volume of u FIG. 3 to noise ratio not less than one-tenth of the ultimate possible with the bridge method. On the other hand, the r.f. -gain is very high and the effect of hum and microphonics are less. The large noise limits the value of the smallest observable signal. It has been found possible to operate the circuit to obtain well-defined nuclear resonances at 200 oersteds field strength. It should be possible to extend the technique to 50 oersteds. As already mentioned, the super-regenerator spectrum consists of a number of side bands and resonances due to all of them could be obtained if the A.C. modulation is large enough. It is found that for proton resonances in solutions of paramagnetic substances, the signal increases in magnitude as the A.C. modulation is increased and then decreases with further increase of A.C. modulation. Application of the phenomenon of nuclear magnetic resonance to other fields of study requires a simple and sensitive apparatus and the selfquenched super-regenerator has been found to meet the requirements. It is of particular use where accurate measurement and monitoring of magnetic fields are concerned. The apparatus described in this paper has been working satisfactorily over a period of many years in this laboratory and has been used for a variety of experiments (Suryan, 1951). Author's thanks are due to Professor R. S. Krishnan for his kind interest and encouragement.

30 G. SURYAN REFERENCES Bloch.. Pound, Purcell and.. Bolembergen Roberts.. Suryan.. Torrey.. Williams and Zimmerman.... Phys. Rev., 1946, 70, 40. Ibid., 1948, 73, 679. Rev. Sei. Inst., 1947, 18, 845. Prat. Ind. Acad. Set, 1951, 33, 107. J. Se!. Inst., 1952, 29, 335. Phys. Rev., 1949, 76, 1059. Ibid., 1949, 76, 350. r