Footwear Foot Grounders Resistive Characterization (not to include static control shoes)

Similar documents
Standard Practice for In-Use Resistance Testing of Gloves and Finger Cots

Worksurfaces Resistance Measurements

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Application of ANSI/ESD S20.20 to Semiconductor Manufacturing. Carl Newberg River s Edge Technical Service, Inc.

EIA STANDARD TP-70B TEMPERATURE RISE VERSUS CURRENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS EIA/ECA B. June 2007 EIA/ECA B

NOTICE. (Formulated under the cognizance of the CTA R7 Home Networks Committee.)

EIA STANDARD TP-95. Full Mating and Mating Stability Test Procedure for Electrical Connectors EIA/ECA EIA

American National Standard. For Wet Process Porcelain Insulators Indoor Apparatus Type ANSI/NEMA C (R2002, R2012)

AMERICAN NATIONAL STANDARD

American National Standard for Electric Power Systems and Equipment Voltage Ratings (60 Hertz)

New Report Indicates AC Inductance/Electrodynamic Dust Detectors May Be Hazardous. Ron Dechene Auburn Systems, LLC Danvers MA 01923

(R) Aerospace First Article Inspection Requirement FOREWORD

AEC-Q REV A June 1, 2000

AS/NZS IEC :2013

NOTICE. (Formulated under the cognizance of the CTA R6 Portable, Handheld and In-Vehicle Electronics Committee.)

TEST PROCEDURE FOR DYNAMIC PULL-OFF PERFORMANCE OF ROOFING FASTENER HEADS OR FASTENERS WITH BEARING PLATES

NOTICE. (Formulated under the cognizance of the CTA R6 Portable, Handheld and In-Vehicle Electronics Committee.)

Serial ATA (SATA) Connector

HMMA 841 TOLERANCES AND CLEARANCES FOR COMMERCIAL DOORS AND FRAMES HOLLOW METAL -07 MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM METAL DOORS & FRAMES

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

Standard Recommended Practice. High-Voltage Electrical Inspection of Pipeline Coatings

NOTICE. (Formulated under the cognizance of the CTA R4 Video Systems Committee.)

TOLERANCES AND CLEARANCES FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES

Current Probes. User Manual

Mar11 Rev J

AS/NZS 1200:2000 AS/NZS


AWS J1.1M/J1.1:2013 An American National Standard. Specification for Resistance Welding Controls

COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE

Standard Test Method for Rubber Deterioration Surface Cracking 1

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

OPEN BASE STATION ARCHITECTURE INITIATIVE

Voltage Reducing Devices Pre-Start and Routine Performance Verification Checks

Paul Dobrowsky Innovative Technology Services

J O I N T I N D U S T R Y S T A N D A R D. Requirements for Soldering Pastes J Standard 005A. December 2011

AS/NZS CISPR 14.2:2015

Continuous On-line Measurement of Water Content in Petroleum (Crude Oil and Condensate)

NOTICE. (Formulated under the cognizance of the CTA R4 Video Systems Committee.)

SECTION PANELBOARDS

This document is a preview generated by EVS

SYNCHRONISING AND VOLTAGE SELECTION

SURFACE VEHICLE RECOMMENDED PRACTICE

Steel wire for general fencing purposes

SOCIETY OF CABLE TELECOMMUNICATIONS ENGINEERS INC

DETAIL SPECIFICATION TRANSMITTER, TEMPERATURE, ELECTRICAL RESISTANCE, -70º TO +300ºC

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories

This document is a preview generated by EVS

NATIONAL RADIO SYSTEMS COMMITTEE

Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process

Alternating-Current High-Voltage Power Vacuum Interrupters Safety Requirements for X-Radiation Limits

OPEN BASE STATION ARCHITECTURE INITIATIVE

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

AMERICAN NATIONAL STANDARD

NRSC-2 Emission Limitation for AM Broadcast Transmission June, 1988

A53106 SERIES DC-TO-DC CONVERTER

AMERICAN NATIONAL STANDARD

Australian/New Zealand Standard

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

SOLARLOK PV BAR Junction Box

SECTION DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Sabritec Qualification Test Report Summary

Rubber, vulcanized or thermoplastic Determination of compression stress-strain properties

MILITARY SPECIFICATION MICROCIRCUITS, DIGITAL, BIPOLAR PROGRAMMABLE LOGIC, MONOLITHIC SILICON. Inactive for new design after 28 July 1995.

Automatic hardness testing devices

Australian Standard. Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv AS

Mar07 Rev B

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Fluid Sealing Association

Mar11 Rev D

AWS C3.9M/C3.9:2009 An American National Standard. Specification for Resistance Brazing

NZFSA Policy on Food Safety Equivalence:

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Standards and Competencies

SURFACE VEHICLE STANDARD

Australian/New Zealand Standard

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

This specification covers performance, tests and quality requirements for MINIPAK* HDL Board Mount Receptacle or Plug Connector System.

Feb 13 Rev F

This is a preview - click here to buy the full publication

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

Declaration of Conformity to the DeviceNet Specification

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

Licensed Copy: RRICTISQ RRICTISQ, ISO/Exchange Russia, 01 December 2004, Uncontrolled Copy, (c) BSI

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

SECTION DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

PERFORMANCE SPECIFICATION GLASS BEADS: FOR CLEANING AND PEENING

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

MAY 14 Rev B

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

VERIFYING THE ACCURACY OF WIRE CLOTH SIEVES

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

NATIONAL RADIO SYSTEMS COMMITTEE

Australian/New Zealand Standard

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Ring crush of paperboard (flexible beam method) (REAFFIRMATION of Classical Method T 818 cm-07) (No changes from previous drafts)

Transcription:

for the Protection of Electrostatic Discharge Susceptible Items- Footwear Foot Grounders Resistive Characterization (not to include static control shoes) Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY 13440

ESD Association Standard Practice for the protection of Electrostatic Discharge Susceptible Items Footwear Foot Grounders Resistive Characterization (not to include static control shoes) Approved September 21, 2003 ESD Association ii

Caution Notice ESD Association standards and publications are designed to serve the public interest by eliminating misunderstandings between manufacturers and purchasers, facilitating the interchangeability and improvement of products and assisting the purchaser in selecting and obtaining the proper product for his particular needs. The existence of such standards and publications shall not in any respect preclude any member or non-member of the Association from manufacturing or selling products not conforming to such standards and publications. Nor shall the fact that a standard or publication is published by the Association preclude its voluntary use by non-members of the Association whether the document is to be used either domestically or internationally. Recommended standards and publications are adopted by the ESD Association in accordance with the ANSI Patent policy. Interpretation of ESD Association Standards: The interpretation of standards in-so-far as it may relate to a specific product or manufacturer is a proper matter for the individual company concern and cannot be undertaken by any person acting for the ESD Association. The ESD Association Standards Chairman may make comments limited to an explanation or clarification of the technical language or provisions in a standard, but not related to its application to specific products and manufacturers. No other person is authorized to comment on behalf of the ESD Association on any ESD Association Standard. Published by: Electrostatic Discharge Association 7900 Turin Road, Building 3 Rome, NY 13440 Copyright 2003 by ESD Association All rights reserved No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America ISBN: 1-58537-083-5 iii

(This foreword is not part of ESD Association Standard Practice SP9.2-2003) Foreword This standard practice was developed to provide test methods for evaluating foot grounders and foot grounder systems used to electrically bond or ground personnel as part of an ESD Control Program. Static Control Shoes are tested using ANSI/ESD STM9.1. This standard practice was processed and approved for submittal to the ESD Association Standards Committee by the 9.2 Foot Grounders Work Group. At the time it was approved, the Working Group had the following members: Dale Parkin, Chair IBM Corporation Brent Beamer Static Control Components, Inc. Steve Koehn 3M Company Larry Burich Lockheed Martin Mark Fancourt Lehigh Safety Shoe Co. The following individuals made significant contributions to this document. Michael J. Manders United States Air Force (USAF) Anna Maria Steriti Wescorp Bruce Lampert United Technical Products, Inc. William Klein K&S Laboratories, Inc. Paul Petersen 3M Company Alan Peters Lehigh Safety Shoe Co iv

Table of Contents 1.0 PURPOSE AND SCOPE...1 1. 1 PURPOSE...1 1. 2 SCOPE...1 2.0 DEFINITIONS...1 3.0 REFERENCED PUBLICATIONS...1 4.0 PERSONNEL SAFETY...1 5.0 LIMITS AND MARKING...2 5.1 LIMITS FOR LABORATORY EVALUATION TESTING...2 5.2 LIMITS FOR COMPLIANCE VERIFICATION...2 5.3 MARKING (LABELING)...2 6.0 TEST METHODS...2 6.1 LABORATORY EVALUATION TESTING OF FOOT GROUNDERS...2 6.1.1 EQUIPMENT...2 6.1.2 TEST AND PRECONDITIONING ENVIRONMENT...2 6.1.3 PROCEDURE...2 6.2 COMPLIANCE VERIF ICATION TESTING OF THE FOOT GROUNDER SYSTEM...3 6.2.1 EQUIPMENT...3 6.2.2 PROCEDURE (INTEGRATED TESTER)...3 6.2.3 PROCEDURE (INS TRUMENTATION)...3 6.3 REPORTING...4 6.3.1 LABORATORY EVALUATION TESTING...4 6.3.2 COMPLIANCE VERIFICATION TESTING...4 TABLE OF FIGURES: FIGURE 1: Foot Grounder Resistance Test..5 FIGURE 2: Bootie Resistance Test.5 FIGURE 3: Foot Grounder Resistance Test..6 APPENDIX A - Tester Voltage Influence on High/Accept/Low Indications.......7 APPENDIX B - Foot Grounder Usage Guidance...7 APPENDIX C - Parallel Ground Paths...7 APPENDIX D - Foot Grounder Laboratory Evaluation Test Report...8 APPENDIX E - Foot Grounder Classification...8 v

ESD Association Standard Practice ESD SP9.2-2003 1.0 PURPOSE AND SCOPE 1.1 Purpose This standard practice describes the electrical test methods for evaluation and compliance verification (periodic testing) of foot grounders. 1.2 Scope This standard practice is intended for testing foot grounders and foot grounder systems used for grounding personnel engaged in working with ESD sensitive assemblies and devices. It does not address static control shoes. 2.0 DEFINITIONS Foot Grounders Personnel grounding device worn on the shoe. The device makes electrical contact with the surface on which the wearer is standing. The device also makes contact with the wearer through either direct skin contact or by contacting moisture inside the shoe. This definition includes heel/toe grounders and booties or similar devices (excluding static control shoes). Flooring / Foot Grounder System Resistance (foot grounder, person and floor): The Flooring / Foot grounder system resistance is the total resistance of the foot grounders when worn by the person standing on a static control floor. Floor Contacting Surface (FCS) That part of the foot grounder that makes electrical contact to the grounding surface. Body Contacting Mechanism (BCM) That part of the foot grounder that makes electrical contact with the body. Foot Grounder System A foot grounder properly worn by a person where the electrical path includes the person and the foot grounder. Foot Grounder System Resistance (foot grounder and person): The foot grounder system resistance is the measure of the total resistance of the foot grounder when worn by the person standing on a stainless steel plate. Current Limiting Resistance A resistance incorporated in the electrical path to ground of foot grounder system. This resistance is intended to limit the electrical current that could pass through the foot grounder in the event of inadvertent user contact with electrical potential. 3.0 REFERENCED PUBLICATIONS ANSI/ESD S20.20 Standard for the Development of an Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment. ASTM D-257 Standard Test Method for D-C Resistance or Conductance of Insulating Materials. ESD STM 97.1 Floor Materials and Footwear Resistance Measurements in Combination with a Person 4.0 PERSONNEL SAFETY The procedures and equipment described in this document may expose personnel to hazardous electrical conditions. Users of this document are responsible for selecting equipment that complies with applicable laws, regulatory codes and external and internal policy. Users are cautioned that this document cannot replace or supersede any requirements for personnel safety. The ultimate responsibility for personnel safety resides with the end user of this document. Ground Fault Circuit Interrupters (GFCI) and other safety protection should be considered wherever personnel might come into contact with electrical sources. 1

Electrical hazard reduction practices should be exercised and proper grounding instructions for the equipment must be followed when performing these tests. 5.0 LIMITS AND MARKING Laboratory Evaluation Tests provide methods for incoming goods inspection. Compliance Verification is a simple check of electrical continuity. Compliance Verification should be used on a regular, user-defined basis, to ensure that the foot grounder system is electrically functional. See Appendix A for additional guidance. 5.1 Limits for Laboratory Evaluation Testing See ANSI/ESD S20.20 for recommended performance criteria and Appendix E for recommended classifications. 5.2 Limits for Compliance Verification See ANSI/ESD S20.20 for recommended performance criteria and Appendix E for recommended classifications. 5.3 Marking (labeling) It is recommended that each foot grounder be marked with the manufacturer s name or logo and the current limiting resistance. 6.0 TEST METHODS 6.1 Laboratory Evaluation Testing of Foot Grounders This test measures the value of the resistance of foot grounders and assures continuity between the discrete parts of the foot grounder. 6.1.1 Equipment The measurement apparatus called the meter, whether it is a single meter or a collection of instruments that are capable of reading from 5.0 x 10 4 ohms to at least 1.0 x 10 10 ohms with a test voltage between 7 to 30 volts DC open circuit. Insulative Support Surface: A flat insulative plate sufficiently large to support the foot grounder under test. The resistance of the insulative surface shall be greater than 1.0 x10 13 ohms per square when measured per ASTM D-257. Electrodes: Two cylindrical 2.27 kg ±.06 kg (5 pound ± 2 oz.) electrodes with a diameter of 63.5 mm ±.25 mm (2.5 inches ±.1 inches) each having contacts of electrically conductive material with a Shore-A (IRHD) durometer hardness between 50 and 70. The resistance between two electrodes should be less then 1.0 x 10 3 ohms when measured at 10 volts on a metal surface. Conductive rubber electrodes are used for material evaluation and qualification. Note: If aluminum foil covered electrodes are used, a correlation between the conductive rubber electrode and the aluminum foil covered electrode should be established for each material to be measured. Note: Over time, conductive rubber materials used as the contact surface of the probes can warp. This could cause measurements to change. At this time there is no standardized method to verify if this has occurred but the user should be aware of this phenomenon. 6.1.2 Test and Preconditioning Environment Specimens shall be preconditioned and tested at two environmental conditions: 1) 12% ± 3% relative humidity, 23 o ± 3 o C. (73 o ± 5 o F) for a minimum of 48 hours but not greater than 72 hours. 2) 50% ± 2% relative humidity, 23 o ± 3 o C. (73 o ± 5 o F) for a minimum of 48 hours but not greater than 72 hours. 6.1.3 Procedure A minimum of six (6) specimens from each sample type shall be preconditioned and tested at 12% RH per 6.1.2. See Figures 1 and 2 for examples of test setups. 2

a) Place the foot grounder on the insulative surface so that the Floor Contacting Surface (FCS) is exposed and parallel to the insulative surface. Place an electrode on the FCS. b) Place the Body Contacting Mechanism (BCM) on the insulative surface so that it contacts the FCS only at the one intended point. The BCM should not make inadvertent contact with straps or other parts of the foot grounder. Place the second electrode on the BCM at the point farthest away from the FCS. c) Measure and record the resistance of the foot grounder. d) Repeat the test for the remaining specimens. e) Repeat steps a through d with a minimum of six (6) specimens from each sample type, preconditioned and tested at 50% RH per 6.1.2. 6.2 Compliance Verification Testing of the Foot Grounder System This test verifies the resistance of the foot grounder system. This can be accomplished by using either an Integrated Tester (6.2.2) or Instrumentation (6.2.3). NOTE: Parallel ground paths can cause false indications. See Appendix C 6.2.1 Equipment Measuring Instrument(s): An integrated foot grounder tester or a measurement apparatus called the meter, whether it is a single meter or a collection of instruments that are capable of reading from 5 x 10 4 ohms to at least 1 x 10 10 ohms with an open circuit test voltage between 7 to 30 volts DC. See Appendix A. Electrode: A stainless steel cylinder 150 mm (6 inches) in length and 25mm (1 inch) in diameter. Foot Electrode: A conductive metal plate, 305mm square (12 inches). All dimensions are nominal. Insulative Support Surface: A base plate larger than the conductive metal plate. The resistance of the insulative surface shall be greater than 1.0 x10 13 ohms per square when measured per ASTM D-257. Note: Users should be aware that the test voltage used here is different from ESD STM 97.1. This difference may produce different results. 6.2.2 Procedure (Integrated Tester) a) Place the foot grounders on the user s shoes per the manufacturer s instructions. b) Place the left foot on the floor plate and touch the body contact area on the tester with one hand. Activate the tester per the manufacturer s instructions. c) Remove the left foot from the floor plate. Record the Accept or Reject indication. Accept and reject criteria are user defined in accordance with Paragraph 5.2. d) Repeat steps b and c above with the right foot. 6.2.3 Procedure (Instrumentation) See figure 3 for an example of a test setup. a) Place the foot grounders on the user s shoes per the manufacturer s instructions. b) Place the foot electrode on top of the insulative support surface. Attach the conductive plate to the common terminal (-) of the instrument. Connect the stainless steel cylinder to the positive terminal (+) of the instrument. c) Place the right foot on the metal plate and grasp the electrode with one hand. Measure the resistance of the foot grounder system. Remove the right foot from the foot electrode. Record the Accept or Reject indication. Accept and reject criteria are user defined in accordance with Paragraph 5.2. d) Repeat steps b and c above with the left foot. 3

6.3 Reporting 6.3.1 Laboratory Evaluation Testing Report the following: Test date, equipment used, foot grounder identification, test voltage, resistance and markings (labeling). See appendix D for test report form. 6.3.2 Compliance Verification Testing Report the following: Test date, foot grounder identification, pass or fail indication. 4

Floor Contacting Surface (FCS) Electrode Foot Grounder Instrument(s) Body Contacting Mechanism (BCM) Insulative Support Surface Figure 1: Foot Grounder Resistance Test Body Contacting Mechanism (BCM) Electrode Bootie Instrument(s) Floor Contacting Surface (FCS) Insulative Support Surface Figure 2: Bootie Resistance Test 5

ESD-SP9.2-2003 Instrument Electrode + _ Foot Grounder Foot Electrode Insulative Support Surface Figure 3: Foot Grounder System Resistance Test 6

APPENDIX A - Tester Voltage Influence on High/Accept/Low Indications Results of a foot grounder continuity test may vary due to skin contact resistance. The variations of the skin resistance are mainly caused by the contact area, and the moisture on the skin. The higher the voltage applied to the skin, the less the skin contact resistance affects the total resistance of the system test. The skin contact resistance during a system test may be high enough that the current limiting resistance of a foot grounder is not correctly indicated. The system tester s open circuit voltage and the test voltage under load can cause the skin contact resistance measurement to vary by tens of millions of ohms. For example, an applied voltage of 1 volt may result in a resistance of 3.0 x10 7 ohms. However, an applied voltage of 30 volts under the same conditions may result in a measured resistance as low as 1.0 x 10 6 ohms. Typically, the variation of the skin contact resistance becomes negligible when the applied voltage exceeds 30 volts. Since exact measurements are not needed for a system test, applied voltages between 7-30 volts DC are usually appropriate. APPENDIX B - Foot Grounder Usage Guidance Compliance verification should be performed prior to each use (daily, shift change, etc.). The accumulation of insulative materials on the FCS may increase the foot grounder system resistance. If foot grounders are worn outside the ESD protected area testing for functionality before reentry to the ESD protected area should be considered. APPENDIX C - Parallel Ground Paths A parallel ground path allows a flow of electrical current through a path that is not intended for the test. Parallel ground paths may be caused by several different situations. For example: a. The path represented by the person standing with one shoe on the floor and the other shoe on the test apparatus. A parallel path may be created by the shoe on the floor. Current from the test instrument is then directed down two paths when it was intended to be directed down one. The correct path for the test is with one shoe in the air or on an insulating surface and the other shoe on the test plate. b. The path presented by a person inadvertently supporting themselves by means of one hand on another object such as a wall, table or supporting member in order to measure the resistance in one foot contact. The hand has created a parallel path to ground. c. The path represented by a person leaning against another object with other parts of the body in order to provide physical support during a testing sequence. This can then lead to other grounding paths and erroneous results. 7

ESD-SP9.2-2003 APPENDIX D - Foot Grounder Laboratory Evaluation Test Report Test Date Foot Grounder Identification Markings: Manufacturer ID Manufacturer Resistance Value Equipment Used Test Voltage Applied Resistance Measured APPENDIX E - Foot Grounder Classification Electrical Resistance Value* Foot Grounder Standard Use Type A 8.0 X 10 5 to 3.5 X 10 7 Foot Grounder Special Use High Type B 3.5 X 10 7 to 1.0 X 10 9 Foot Grounder Special Use Low Type C <8.0 X10 5 * Resistance values are obtained from evaluation or compliance verification testing. 8

Foot Grounder Classification Standard use: Type A (standard) foot grounder has a lower resistance limit of 8.0x10 5 ohms to limit current flow to <0.5 milliamp at 240 VAC. The upper resistance limit of less than 3.5x10 7 ohms is defined by ANSI/ESD S20.20 as the recommended person to ground resistance value. Special use: Special electrical performance characteristics of materials used to make foot grounders may be required to achieve product attributes such as non-marking and high durability or very low resistance for handling some components. These special characteristics may necessitate foot grounder resistance values outside of the recommend level defined in ANSI/ESD S20.20. 9