MODEL: 47LV. Digital Panel Meters 47 Series

Similar documents
MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT

[3] MOUNTING DIRECTION

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: W2TS. Mini-MW Series

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M1EXT. with Display M1E Series

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: M2DYS SEN TRONIC AG

MODEL: MRP6. Final Control Elements

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: R30US4. Remote I/O R30 Series

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: 47DV. Digital Panel Meters 47 Series

Adjustable Digital Process Instrument MDK480

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: 47DR. [2] EXCITATION SUPPLY 1: +12 V sensor excitation 2: +24 V two-wire transmitter excitation. Digital Panel Meters 47 Series

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

Digital Indicator DS 96/24

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Digital panelmeter with microprocessor based technology 5 digit. 4 free scalable setpoints/hysteresis/delay time (option)

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

MODEL: 47DT. Digital Panel Meters 47 Series

DIGEM f 96 x 48 EK. Applications. Description

ELECTRONIC DC INPUT METER

Digital Indicator DS 96/48 PK

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

Process displays For standard signals, temperature, resistance measurement

N30P DIGITAL PANEL METER

SIA, SIB, SIC, SID. User's Manual

MODEL: DAST-20. Telemetering System

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: TC10EM. Temperature Controller TC10 Series

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Digital indicator for panel mounting With multi-function input Model DI25

Monitoring Relay MR 50

SHIMADEN DIGITAL INDICATORS

2017 Advanced Energy Industries, Inc. HITEK POWER MH60 SERIES VERSATILE HIGH-VOLTAGE POWER SUPPLY MODULES

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Solid-state Twin Timer

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

SHIMADEN DIGITAL INDICATORS

Economical Digital Indicators For Process and Electrical Measurement

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

GC83 Digital Indicators & GC93 Digital Meter Relay

Series 10-ZSE30A(F)/10-ISE30A

Instruction Manual. Digital Panel Meter Model 3153B

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure

OMRON MK-I / -S RELAY

JPQ2 PULSE ACCUMULATOR

Type CP-S, CP-C & CP-A Switch mode

Solid-state Timer H3DS

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

DP2000 ORDERING GUIDE To Order MODEL NO.

48 Series - Relay interface modules A. Features

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RCMS460 and RCMS490 Series

JUMO dtrans T02 LCD programmable transmitter. B Operating Instructions 10.00/

Electronic Circuit Breaker ESS20-0..

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

General Specifications

General-purpose Relay

62 Series - Power relays 16 A. Features / /

Transcription:

Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display flickering Scaling, forced zero, low-end cutout Max. and Min. value display Safety terminal cover tethered to the device with a strap IP66 front panel Separable terminal block 96 (.78) : 0 0 V DC (Load resistance 0 kω min.) 5: 0 5 V DC (Load resistance 5000 Ω min.) 6: 5 V DC (Load resistance 5000 Ω min.) W: -0 0 V DC (Load resistance 0 kω min.) [] ALARM OUTPUT 0: None : N.O. relay contact, points : SPDT relay contact, points [] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White 8 (.89) HH H P L LL Zro Spn D/P Tch Fnc Min Max Max/Min Alarm/ Scale/ Shift Up 98.5 (.88) mm (inch) MODEL: 7LV-[][][][]-[5][6] ORDERING INFORMATION Code number: 7LV-[][][][]-[5][6] Specify a code from below for each [] through [6]. (e.g. 7LV-0G-M/Q) Specify the specification for option code /Q (e.g. /C0/S0/SET) [] INPUT : ±0 V, ±5 V, 0 5 V, 5 V 0 0 ma, 0 ma : ± V, ±00 mv, ±0 mv, ± ma : ±00 V, ±00 ma : ±00 μa (CE not available) 5: ± A, ± A (CE not available) 6: ±700 V (CE not available) [] DC OUTPUT 0: Without Current A: 0 ma DC (Load resistance 550 Ω max.) D: 0 0 ma DC (Load resistance 550 Ω max.) Voltage : 0 V DC (Load resistance 000 Ω min.) (CE not available) [5] POWER INPUT AC Power M: 00 0 V AC (Operational voltage range 85 6 V, 50/60 Hz) DC Power R: V DC (Operational voltage range V ±0 %, ripple 0 %p-p max.) P: 0 V DC (Operational voltage range 85 50 V, ripple 0 %p-p max.) [6] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating TERMINAL SCREW MATERIAL /S0: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-950) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP66; applicable to the front of the panel meter mounted according to the specified panel cutout Connection: M separable screw terminal (torque 0.6 N m) Screw terminal: Nickel-plated steel (standard) or stainless http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page /7

steel Housing material: Flame-resistant resin (gray) Isolation: Input to DC output to HH output or H output to L output or LL output to power Setting: (Front button) Scaled range Input type Alarm setpoint Hysteresis (deadband) Moving average Others (Refer to the instruction manual for details) Read rate: 0 times/sec. (5 msec.) Averaging: None or moving average Lockout setting: Prohibiting certain operations; protecting settings DISPLAY Display: 6 mm (.6) high, ½ digits, 7-segment LED Display range: -9999 to 9999 Decimal point position: 0, 0, 0, 0 or none Zero indication: Higher-digit zeros are suppressed. Over-range indication: -9999 or 9999 blinking for display values out of the display range. S.ERR and Min or Max blinking when the input signal is out of the usable range. Alarm status indication LL indicator: Green LED turns on when the LL alarm is tripped. L indicator: Green LED turns on when the L alarm is tripped. H indicator: Red LED turns on when the H alarm is tripped. HH indicator: Red LED turns on when the HH alarm is tripped. P indicator: Amber LED turns on when none of the other alarms is tripped. Only P turns on with no-alarm-output type. LL or HH does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. Function indicators: Zro, Spn, D/P, Tch, Fnc, Min, Max Display mode status and operation status, amber ON or blink Engineering unit indication: Sticker label attached DC, AC, mv, V, kv, μa, ma, A, ka, mw, W, kw, var, kvar, Mvar, VA, Hz, Ω, kω, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s, inch, l, l/s, l/min, l/h, m, m /sec, m /min, m /h, Nm /h, N m, N/m, g, kg, kg/h, N, kn, Pa, kpa, MPa, t, t/h,, F, %RH, J, kj, MJ, rpm, sec, min, ph, %, ppm, etc. INPUT SPECIFICATIONS Default setting Input code : Measuring range ±0 V Input code : Measuring range ± V Input code : Measuring range ±00 V Input code : Measuring range ±00 μa Input code 5: Measuring range ± A Input code 6: Measuring range ±700 V Overload capacity Input code 5: ± A for 0 sec., ±. A continuous Input code 6: ±000 V for 0 sec., ±80 V continuous DC INPUT TYPE MEASURING OPERATIONAL INPUT IND RANGE RANGE IMPEDANCE V0 ±0V - V MΩ minimum V5 ±5V -5.5 5.5V MΩ minimum V0-5 0 5V -0. 5.V MΩ minimum V-5 5V 0.7 5.V MΩ minimum A0-0 0mA - ma approx. 0Ω A- 0mA ma approx. 0Ω V ±V -..V MΩ minimum V0 ±00mV -0 0mV MΩ minimum V00 ±0mV - mv MΩ minimum A ±ma -..ma approx. 00Ω V00 ±00V -0 0V MΩ minimum A00 ±00mA -0 0mA approx. 0Ω A0 ±00μA -0 0μA approx. kω A- ±A -..A approx. 0.Ω A- ±A -..A approx. 0.Ω V700 ±700V -770 770V MΩ minimum OUTPUT SPECIFICATIONS DC Output DC Current Operational range: -5 05 % DC Voltage Operational range: -5 05 % Alarm Output: Relay contact Rated load: 50 V AC @ A (cos ø = ) 0 V DC @ A (resistive load) Maximum switching voltage: 50 V AC, 0 V DC Maximum switching power: 750 VA, 90 W (resistive load) Minimum load: 5 V DC @ 0 ma Mechanical life: 5 0 6 cycles (rate 80 cycles/min.) INSTALLATION Power consumption AC: Approx. 6.5VA DC: Approx. W Operating temperature: -0 to 55 C ( to F) http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page /7

Operating humidity: 0 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 00 g (0.66 lb) PERFORMANCE Accuracy Display: ±0. % ± digit ± 0. % ± digit for ± 0 mv range Output: ±0. % (DC output = display output) Temp. coefficient: ± 0.05 %/ C (± 0.008 %/ F) ±0.0 %/ C (±0.0%/ F) for ±0 mv range Input resolution: Max. 6 bits Output resolution: Max. bits Response time: 0.5 sec. (alarm output: 0 00 % at 90 % setpoint) 0.5 sec. (DC output: 0 90 %) Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 500 V DC Dielectric strength: 000 V AC @ minute (input to DC output to HH output or H output to L output or LL output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 6000-6- EMS EN 6000-6- Low Voltage Directive EN 600- Measurement Category II (alarm) Installation Category II (power) Pollution degree Input or DC output to alarm output to power: Reinforced insulation (00 V) Input to DC output: Basic insulation (00 V) RoHS Directive EN 5058 Protection against access to the terminal blocks: Finger protection (VDE 0660-5) EXTERNAL VIEW () Main Display () Alarm Indicators () Function Indicators HH H P L LL Spn D/P Tch Fnc Min Max Zro Max/Min Alarm/ Scale/ Shift Up () Max/Min Button (5) Alarm/ Button (7) Shift Button (6) Scale/ Button (8) Up Button http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page /7

COMPONENT IDENTIFICATION No. COMPONENT FUNCTION () Main display Indicates present values, setting values and status of the unit. () Alarm indicators Indicate alarm status of the input signal. () Function indicators Indicate the status in each setting mode. () Max/Min button Used to switch the main display to show the present values, maximum values or minimum values etc. (5) Alarm/ button Used to confirm alarm setpoints, to move on to the alarm and other setting modes; or to shift setting mode. (6) Scale/ button Used to move on to the scaling and other setting modes; or to shift through setting items in each through setting items in each setting mode. (7) Shift button Used to move on to the setting standby status of each setting mode and shift through display digits in each setting item. (8) Up button Used to change setting values, to execute/cancel Forced Zero or to select setting values. Refer to the instruction manual for details. EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) TOP VIEW 95 (.7) FRONT VIEW 0 (.06) SIDE VIEW 98.5 (.88) 96 (.78).5 (.9) 86 (.9) (.08) 8 (.89) 7 (.85) REAR VIEW No Alarm Output Alarm Output 6.6 (.6) 0M SCREW TERMINAL 0M SCREW TERMINAL M SCREW M SCREW 5 (.77) 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 0 9.5 (.60) http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page /7

MOUNTING REQUIREMENTS unit: mm 9 0 0.8 min. 75 5 0 0.6 min. 0 Panel thickness:.6 to 8.0 mm http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page 5/7

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM ALARM OUTPUT CODE 0: No alarm output Isolation INPUT* A/D Converter Digital Computation Output Driver 7 8 9 0 DC OUTPUT U() POWER V() 5 6 Display / Setting ALARM OUTPUT CODE : N.O. contact, points Isolation INPUT* 5 6 A/D Converter Display / Setting Digital Computation Output Driver 7 8 5 6 7 8 9 0 9 0 DC OUTPUT HHa HH OUTPUT Ha H OUTPUT Hc, HHc La L OUTPUT LLa LL OUTPUT Lc, LLc U() V() POWER ALARM OUTPUT CODE : SPDT contact, points Isolation INPUT* A/D Converter Digital Computation Output Driver 7 8 5 6 DC OUTPUT Ha (NO) Hb (NC) H OUTPUT Relay Protection AC Powered LOAD DC Powered Inductive Load (Coil) Varistor or CR Circuit Inductive Load (Coil) 5 6 Display / Setting 7 8 9 0 9 0 Hc (COM) La (NO) Lb (NC) Lc (COM) U() V() L OUTPUT POWER LOAD Diode, Varistor or CR Circuit Note: The section enclosed by broken line is only with DC output option. * Input shunt resistor incorporated for current input. Input code:, Input code: Input code: Input code : 5, 6 V V V I I COM COM http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page 6/7

Input Terminal Assignments INPUT TYPE MEASURING INPUT (indicator) RANGE TERMINALS V00 V0 ±00V ±0V V5 ±5V V ±V A- ±A A- ±A V700 ±700V V0 V00 ±00mV ±0mV INPUT TYPE MEASURING INPUT (indicator) RANGE TERMINALS V0-5 V-5 0 5V 5V A00 A ±00mA ±ma A0-0 0mA A- A0 0mA ±00μA Specifications are subject to change without notice. http://www.m-system.co.jp/ 7LV SPECIFICATIONS ES-950 Rev. Page 7/7