Installation Instructions: Urbanline Alu Selekta Clad

Similar documents
Installation Instructions: Urbanline Euro Selekta Clad

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

15 YEARS GUARANTEE no swelling no cracking no splintering no rotting

INSTALLATION INSTRUCTIONS

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR CONCEALED FASTENERS PRESSURE EQUALIZED WALL SYSTEM

NATURA PRO Product Information Leaflet 1

The Passive Fire Protection Handbook

March High performance building boards

The Passive Fire Protection Handbook

DAYLIGHT HARVESTING MULTIWALL. Applications:

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

The Passive Fire Protection Handbook

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent

Architectural Interior Wall Paneling

Fir and pine wood (52 %) Portland cement (38 %) made by firing limestone and clay Water (9 %) Wood mineralisation substances (1 %)

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E

Technical Documentation

Wave Profile Installation Guide

Processing and design Solid Textile Board

Installation instructions for co-extruded louver-board profiles

Corrugated Sheet. Installation Instructions

Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines

Installation instructions: Elements Vulcan+ Newport Hector Cladding

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.

HOLLOW CORRUGATED SHEETS

60.AL. Lauder. Facade LAUDESCHER

Classic Touch 8.0 Product description P D09 Stand: 01.14

Installation Instructions

Façade CUT-TO-SIZE FAÇADE STRIPS APPLICATION IN OVERLAP ON WOODEN SUPPORTING STRUCTURE APPLICATION INSTRUCTIONS 1 1. GENERAL

Installation Instructions

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

The matte surface is created and protected with acrylic varnishes, the high gloss surface is proteced by pressing with melamine.

Endura-Classic Craftsman Information

VITREOUS ENAMEL PANEL

WITH HEAT - NATURALLY

Subframe Installation Guide

pacific build supply ltd

Components made of special materials. Floor Elements for Profile St Profile KH. Fastening Elements for Profile KH

TruGrain 6 and 4 Flat Board Siding System Assembly Installation Guidelines

Shapes Siding. Perfection Shingles. Chalk Line

Installation Guide. Guardian Slate Roof System. England, Scotland & Wales

Western Red Cedar Shingles Product Guide

GLUED SOLID TIMBER DUO/TRIO

An eco-friendly beginning

Bird Feeder BUILD TIME

TIMBER HANDRAILS & BALUSTRADES

STRUCTURAL PERFORMANCE OF TIMBER EXTERNAL CLADDING

Endless. millions of dreams

Decor Plus and Uni Plus

How-to-Install. Laminate Countertops and Sheet Laminate. FREE brochure Reverso en español

Kestrel Aluminium Systems Limited. Product Manual Section 11 Thermal Framing System - Fabrication. Manual Version

NewTechWood Screening Installation Guide. v au

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

KERRAFRONT INSTRUCTION FOR INSTALLATIONS AND USE. Cellular cladding FS-201 / FS-202. kerrafront.com

Stabalux T. 5.0 Stabalux T 1

Beds may be put up or taken down quickly by use of a simple bolted connection at rails and uprights. MATERIALS LIST

miramondo Technical Informations 1/10 Hop Hop

Installation Guide (888)

BARRELL VAULT BATTENLESS

Installation Instructions: Urbanline Valchromat MDF Panelling

4728 Gravois Ave. St. Louis, MO SIMAX

SHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE

4256HM JAMES HARDIE MONOLITHIC CLADDING

STORAGE, HANDLING and USER INSTRUCTIONS

Installation Guide (888)

Technical product descriptions WORKTOPS STANDARD SLIM LINE. 1. Material thickness 38 mm. 2. Core/substrate material Chipboard

Secret Fixed Shiplap rev OCT External Cladding. 70x19mm Secret Fixed Shiplap 1

miramondo Technical Informations 1/7 La Strada

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

12 x 12 Flat Top Pergola

Cembrit Plank & Cembrit Panel

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM

PAREFEU PANEL Environmentally Sustainable Product with High Fire Rating

Contents. Installation Guide. Dynex Soffit Installation Guide V03 March The Smart Choice in Soffit

A Shell construction

INSTALLATION GUIDE DECKING.

WET AREA PANELLING. Designer Walls. Fast

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

Installation Instructions

DIY SHED GUIDE Planning your Project I Simple Illustrations I Hints

Makrolon Solid Polycarbonate Sheets

Contents. Storage and Handling. 4. Usage. 5. Wood Moisture Content. Cutting and Machining. 6. Screws and Fasteners. 7. Gluing.. 8. Painting.

PRODUCT INTRODUCTION

SECTION CARPENTRY

12 x 24 Flat Top Pergola

Arbor BUILD TIME. Cutting parts: 2 3 hours Assembly: 2 hours Finishing: 2 4 hours Total: 6 9 hours. *Note: Drill pilot holes for all screws

Stabalux AK-S. 3.0 Stabalux AK-S 1

Barofor Round System (polyester coated) Panels, Posts, Accessories

Cabonyx Installation Manual

V Joint Shiplap rev OCT External Cladding V JOINT SHIPLAP 1

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

LuxCore Installation Instructions

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

INSTALLATION INSTRUCTIONS MILLENNIUM DECKING Before Installing Millennium Decking, please read these instructions in their entirety.

PROVEN WISA PLYWOOD FOR CONCRETE FORMING on time and on the spot to grow your business

STEEL FRAMING WEATHERBOARD SYSTEM

Wet Area Panelling. Linear Series

Rev. 05/16 01 ACRYLIC INSTALLATION GUIDE

Installer s Handbook. Pocket Guide to Roofline & Cladding Installation BBA BRITISH BUILDING PRODUCTS

Transcription:

Product description Ecology Technical data Urbanline Alu Selekta Clad (selekta façade profiles and heritageselekta façade profiles) are identical in terms of their core material and surface texture. However, they are available with different surface coatings. The particle wood core consists of processed timber. We use exclusively untreated pulpwood in the form of wood shavings, thinning material and round timber from sustainable, domestic forestry. We do not use imported timber, especially from tropical climates. The binding agent used is a thermosetting artificial resin with building authority approval for outdoor use. As a wood preservative, we use an eco-friendly boron-based product with building authority approval that does not contain lindane or PCP. For the low flammability version, a mixture of boric acid and borax is used as a fire protection agent. No isocyanates, phosphates or halogens are added. Several layers of paper are impregnated with artificial resins for use as a coating. The surface and core are fused together without seams in a single process under the application of pressure and heat. Colorpan Base coating of paper impregnated with melamine resin, followed by coloured Colorpan surface coating using a pure, water-based acrylate. The pigments added are free of toxic heavy metals (no lead, chrome or cadmium). Dekopan Plus Multi-layer coating, printed or dyed; transparent, weather-resistant surface coating of the decor side. Rear side brown, no colour options. Cutting waste may not be burnt in small-scale incinerators (heating boilers, furnaces, fireplaces) according to the German ordinance for small-scale incinerators. There are no restrictions concerning its incineration in industrial wood incineration plants according to Section BImSchV No. 8. (German Federal Immission Protection Ordinance). Cutting waste corresponds to category AII of the German ordinance for the disposal of waste wood (Altholz-Verordnung). Scraps or removed material may in principle be disposed of as household waste or bulky refuse in a landfill or by incineration; however, please observe the requirements of your waste disposal service. Alu Selekta The Alu Selekta façade profiles are made of aluminium. The surface coating can be universal, powder coating or decorative coating (wood decor). v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Technical data Values Unit Test specification. Density 700 kg/m EN. Flexural strength - N/mm EN 0 / EN 8. Elasticity modulus 70000 N/mm EN 0 / EN 8. Tensile strength vertical to the surface N/mm EN 9. Tensile strength - N/mm EN ISO 7 / EN 8 6. Screw withdrawal strength ) - N/mm WERZALIT TEST STANDARD 7. Swelling after storage after h in water at 0 C after h at 00 C after h 0.0 0.0 0.0 % % % DIN 7 DIN 7 VHI quality seal / WERZALIT TEST STANDARD 8. Moisture content 0.0 % EN 9. Temperature resistance under permanent load under temporary load 0. Fire behavior, standard version special version -0 to +70 +0 non-flammable. Length change due to moisture/heat exposure ) mm/m C C WERZALIT TEST STANDARD DIN 0- resp. DIN EN 0- WERZALIT TEST STANDARD. Thermal conductivity λ 80 W/m K DIN 6. Water vapour permeability diffusion-equivalent air layer thickness 0 m DIN 6. Cross-cut test ) Gt 0A Gt A EN ISO 09. Scratch resistance 0.. N EN 8 WERZALIT TEST 6. Brinell hardness ) - N/mm STANDARD 7. Abrasion behaviour - U EN 8 8. Light fastness Level 8 EN ISO 0-B0 9. Chemical resistance limited resistance EN 8 0. Cigarette burn resistance resistant to burns as for EN 8. Colour deviation ) Δ E < DIN 0. Impact load impact resistant WERZALIT TEST STANDARD / ETB Directive ) mm particle board screw, using a hole of mm diameter, 0 mm deep ) Maximum expected length change under extreme climate fluctuations ) Gt 0A is the best, Gt A is the worst value ) 000 N, s application time, (force/area) ) With measurement geometry 0 /, standard illuminant C v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

General information, Profile dimensions, Calculating the required quantity & Guidelines Scope The scope of these installation instructions covers all installation variants of façade cladding, including soffits. 70 Coverage widths + - 7 0,8 9 8 7, 8 Calculating the required quantity (Calculation values exclude cutting waste) Required quantity/m Required quantity/m Coverage width Standard lengths Façade profile self-drilling screws.9 x 6, stainless steel A Urbanline Alu Selekta Clad at max. fastening spacing = 6 mm Alu Selekta mm 80 mm 6. linear m 0. pcs. Installation lengths For installation lengths of more than 00 mm, the profiles must be cut to a maximum length of 700 mm in order to minimise the expansion joints. Sub-framework for façade cladding According to DIN 0, Part, the increased wind suction at the edge areas of the building walls must be considered when planning the sub-framework. The fastening spacing of the WERZALIT façade profiles must be reduced to max. 00 mm in these areas; additional support battens must be provided as necessary. Wind side e Top view d View A (cladding side) The DIN requirements are presented here in a simplified form as a general rule of thumb. Precise information on this topic must be taken from DIN 0, Part from March 006. The building dimensions are naturally of primary importance for determining the size of area A with increased wind suction (exterior pressure coefficients). Example: Wind side A B Wind side Cladding side Area with increased suction e = m d = 8 m A = e/ = m e/ d d-e/ Batten spacing in area A max. 00 mm Normal area B = d-e/ = m Batten spacing in area B max. 6 mm Fire protection If two opposite main wind directions exist (e.g. west/east), area A must naturally also be observed on the other side of the cladding wall. In the above example, area B would then only be m wide. Alu Selekta is considered to be non-combustible in accordance with Clause C.(e) of the BCA and permitted to be used where the BCA nominates non-combustible material. v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Horizontal installation max 6. Alu Selekta façade profiles. Self-drilling screw.9 x 6, stainless steel A. Aluminium sub-framework, spacing approx. 6 mm, structural analysis to be performed by the customer 600-6. Alu Selekta façade profiles. Self-drilling screw.9 x 6, stainless steel A. Cover profile v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Horizontal installation. Alu Selekta façade profiles. Cover profile. Aluminium sub-framework. Horizontal Starter profile. Self-drilling screw.9 x 6, stainless steel A max. 0 v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Horizontal installation. Alu Selekta façade profiles. Z profile. Self-drilling screw.9 x, stainless steel A 0 mm. Self-drilling screw.9 x 6, stainless steel A. Ventilation profile 0/90 6. Connection profile F 6 mm 6 v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Horizontal installation. Alu Selekta façade profiles. External corner C. Aluminium external corner profile. Aluminium internal corner profile.. v.ul..7.7 7 Phone 00 68 68 Email sales@urbanline.com.au

Vertical installation A Sub-framework. Alu Selekta façade profiles. Self-drilling screw.9 x 6, stainless steel A. Aluminium sub-framework, spacing approx. 6 mm, structural analysis to be performed by the customer. Self-drilling screw.9 x, stainless steel A. Vertical starter profile max. 6 8 v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Vertical installation. Alu Selekta façade profiles. Aluminium sub-framework. Self-drilling screw.9 x 6, stainless steel A. Self-drilling screw.9 x, stainless steel A.. External corner C 6. Aluminium external corner profile 7. Aluminium internal corner profile. 6 9 v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au

Vertical installation. Alu Selekta façade profiles. Aluminium sub-framework. Connection profile F. Z profile. Ventilation profile 0/90 0 mm v.ul..7.7 0 Phone 00 68 68 Email sales@urbanline.com.au

General guidelines Arguments for a back-ventilated curtain cladding of the exterior wall Energy savings Weather protection Attractive design Increased building value Handling The selekta façade profiles must be stored in their packaging, lying flat and dry until use. Sawing with power tools Hard metal saw blade, high number of teeth, (tooth pitch approx. 0 mm), saw blade with alternate top bevel or hollow-tooth flat-top teeth. Sawing with hand saws A well-sharpened and dressed saw with small teeth is sufficient. Sub-framework Façade profiles are typically fastened to a wood sub-framework. In principle, the following guidelines should be followed for wood sub-frameworks: a) The wood must correspond to grade to Australian Building Codes. b) The sub-framework must be fastened using dowels and screws with building authority approval and in accordance with the instructions of the manufacturer. c) The support battens must be fastened to the counter battens with at least wood screws, stainless steel A, per intersection, in a diagonal arrangement, or as per Australian Building Codes. d) The sub-framework must be level and plumb. Back ventilation The back ventilation spacing must be at least 0 mm. Sealing cut edges Cut edges must be sealed free of pores with Werzalit edge sealant. Fastening the façade profiles Only with WERZALIT façade screws. x 0, stain- less steel A. Centre the fastening screws through the existing punched holes. The screws may only be screwed in until the screw head rests against the surface. Hole ø 9 mm, (due to the possible length change of the façade profiles) Fastening of all connection profiles Only with WERZALIT façade screws. x 0, stainless steel A. Please note: Heavy structures, such as an awning, climbing trellis, etc., may not be fastened directly to the cladding or its sub-framework. Provide separate sub-frameworks. Exception: Sufficiently covered cut edges under the roof overhang. Cut edges In coastal regions (up to approximately 0 km inland), all cut edges must be protected against filiform corrosion. Expansion The length change of the façade profiles is approx. mm/linear m, depending on moisture and temperature. Expansion joints of 0 mm must be maintained at profile butt joints and profile connections. If you have additional questions, please contact Urbanline Architectural 00 68 68. Subject to changes due to technical improvements. v.ul..7.7 Phone 00 68 68 Email sales@urbanline.com.au