Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Similar documents
Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

Fluke 5820A Oscilloscope Calibrator Specifications

5500A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications

5080A Multi-Product Calibrator

5502A Multi-Product Calibrator. Extended specifications

5522A Multi-Product Calibrator Extended specifications

5820A. Service Manual. Oscilloscope Calibrator

5820A. Service Manual. Oscilloscope Calibrator

Oscilloscope Calibrator

5790A Automated AC Measurement Standard

Fluke 83V and 87V Digital Multimeters

Fluke 8845A/8846A Digital Multimeters Extended Specifications

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

PXIe Contents. Required Software CALIBRATION PROCEDURE

G5100A: 50 MHz Arbitrary Function Generator

1587/1577 Insulation Multimeters

Model MHz Arbitrary Waveform Generator Specifications

Arbitrary/Function Waveform Generators 4075B Series

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Arbitrary/Function Generators AFG3000C Series Datasheet

280 Series Waveform Generators A selection of universal waveform generators offering superior performance and excellent value

5520A. Getting Started. Multi-Product Calibrator

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

DG5000 Series Specifications

Arbitrary/Function Generator AFG1000 Series Datasheet

Model 310H Fast 800V Pulse Generator

Racal Instruments. Product Information

Synthesized Function Generators with Versatile Arbitrary Waveform Capabilities. Synthesized Function Generator. Technical Data.

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

AWG-GS bit 2.5GS/s Arbitrary Waveform Generator

PM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator

PicoSource PG900 Series

DG4000 Series Waveform Generators

MODELS WW5061/2. 50MS/s Single/Dual Channel Arbitrary Waveform Generators

PicoSource PG900 Series USB differential pulse generators

GFT Channel Digital Delay Generator

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Agilent 81133A/81134A

Analog Arts SF900 SF650 SF610 Product Specifications

Keysight Technologies N9320B RF Spectrum Analyzer

Function/Arbitrary Waveform Generator

Models 296 and 295 combine sophisticated

Agilent N9320B RF Spectrum Analyzer

Fluke 170 Series True-rms Digital Multimeters

5500A. Service Manual. Multi-Product Calibrator

Agilent 8902A Measuring Receiver

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

5790A/AF AC Measurement Standard

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

8845A/8846A 6.5 Digit Precision Multimeters

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Traceability for Oscilloscopes and Oscilloscope Calibrators

Analog Arts SF990 SF880 SF830 Product Specifications

9640A RF Reference Source Calibration made simpler

MPS Electrical Test Laboratory, Larsen & Toubro Limited, Mysore Campus, KIADB Industrial Area, Hebbal Hootagalli, Mysore, Karnataka

Installation Tester and DMM Kits

Fluke 1587 FC/1577 Insulation Multimeters

Agilent 83711B and 83712B Synthesized CW Generators

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Manual Supplement Fluke Corporation. All rights reserved. Printed in U.S.A. x

Fluke Norma 4000/5000

Chapter 5 Specifications

Interpreting Specifications

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Oscilloscope calibration Application Note

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Arbitrary/Function Generator AFG1000 Series Datasheet

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Arbitrary Function Generator AFG1022 Datasheet

MODELS 5251/ MS/s PXIBus / PCIBus Arbitrary Waveform / Function Generators

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

GT 9000 GT 9000S MICROWAVE

Arbitrary Function Generator AFG1000 Series Datasheet

5500A. Multi-Product Calibrator. Operator Reference Guide. PN December, 1994

2026Q CDMA/GSM Interferer MultiSource Generator

Chapter 13 Specifications

DG5000 series Waveform Generators

5522A. Getting Started. Multi-Product Calibrator

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Specifications DG1022 & DG1022A

15. Specifications WF1947/WF

This DDS function generator is designed for use in such applications as communication equipment and electronic components production.

HP 8560 E-Series Spectrum Analyzers Technical Specifications

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

Data Sheet. DG1000 series Dual-Channel Function/Arbitrary Waveform Generators. Product Overview. Main Features. Applications. Easy to Use Design

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

RIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Transcription:

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators Extended Specifications These specifications apply to the 5520A-SC1100, 5500A- SC600 and 5500A-SC300 Oscilloscope Calibration Options. For general specifications, see the Extended Specifications for the individual calibrator of interest (downloadable from the Fluke Calibration web site or available from your Fluke Calibration representative).the specifications are valid when the calibrator is operated under the conditions specified in the operator manual, and has completed a warm-up period of at least twice the length of time the calibrator was powered off, up to a maximum of 30 minutes. The 5520A-SC1100, with 1100 MHz bandwidth, can be installed in a 5522A calibrator. The 5500A- SC600, with 600 MHz bandwidth, can be installed in any 55XX Series Multi-Product Calibrator. The 300 MHz option, the 5500A-SC300, is only compatible with the 5502A calibrator.

Voltage Function Specifications Volt Function DC Signal Square Wave Signal 1 Load Into 50 W Into 1 MW Into 50 W Into 1 MW Amplitude Characteristics 0 V to ± 6.6 V 0 V to ± 130 V Adjustment range 1 mv to 24.999 mv 25 mv to 109.99 mv 110 mv to 2.1999 V 2.2 V to 10.999 V 11 V to 130 V ± (0.25 % of output + 40 µv) 1-2-5 (e.g., 10 mv, 20 mv, 50 mv) ± (0.05 % of output + 40 µv) Square Wave Frequency Characteristics 1 µv 10 µv 100 µv 1 mv 10 mv Continuous 10 Hz to 10 khz ± (2.5 ppm of setting) ± 1 mv to ± 6.6 V p-p ± (0.25 % of output + 40 µv) Typical abberation (from 50 % of leading/trailing edge) 25 mv to 130 V: within 4 µs < (0.5 % of output + 100 µv) 10 mv to 25 mv: within 8 µs 1 mv to 10 mv: within 14 µs 1 Positive or negative, zero referenced square wave. 2 Above 1 khz, ± (0.25 % of output + 40 µv). Assumes connectors and cables are in good condition. ± 1 mv to ± 130 V p-p ± (0.1 % of output + 40 µv) 2 5500A-SC300 Volt Function DC Signal Square Wave Signal 1 Load Into 50 W Into 1 MW Into 50 W Into 1 MW Amplitude range 0 V to ± 2.2 V 0 V to ± 33 V ± 1.8 mv to ± 2.2 V p-p Frequency range 1 Positive or negative, zero referenced square wave. ± (0.25 % of output + 100 µv) 1-2-5 (e.g., 10 mv, 20 mv, 50 mv) 10 Hz to 10 khz ± 1.8 mv to ± 105 V p-p 2 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators

Edge Function Specifications Edge Characteristics into 50 Ω 1-Year Absolute Uncertainty, tcal ± 5 C Amplitude Rise time < 300 ps + 0/-100 ps (p-p) 5.0 mv to 2.5 V ± (2 % of output + 200 µv) Adjustment range values 4 digits ± 10 % around each sequence value (indicated below) 5 mv, 10 mv, 25 mv, 50 mv, 60 mv, 80 mv, 100 mv, 200 mv, 250 mv, 300 mv, 500 mv, 600 mv, 1 V, 2.5 V Other Edge Characteristics Frequency range 1 khz to 10 MHz 1 ± (2.5 ppm of setting) Frequency range 300 ps 1 (+ 0 ps/-100 ps) Typical jitter, edge to trigger < 5 ps [p-p] Leading edge abberations 2 within 2 ns from 50 % of rising edge] < (3 % of output + 2 mv) 2 ns to 5 ns < (2 % of output + 2 mv) 5 ns to 15 ns < (1 % of output + 2 mv) after 15 ns Typical duty cycle 45 % to 55 % Tunnel diode pulse drive 1 Frequency range above 2 MHz has rise time specification 350 ps. 2 Below 250 mv aberrations are typical. < (0.5 % of output + 2 mv) Square wave at 100 Hz to 100 khz, with variable amplitude of 60 V to 100V p-p 5500A-SC300 Edge Characteristics into 50 Ω 1-Year Absolute Uncertainty, tcal ± 5 C Amplitude range (p-p) 4.5 mv to 2.75 V ± (2 % of output + 200 µv) Frequency range 1 khz to 1 MHz ± (25 ppm of setting + 15 mhz) Rise time 1 ns Typical jitter, edge to trigger < 5 ps (p-p) Leading edge aberrations Within 10 ns < (2 % of output + 2 mv) 10 to 30 ns < (1 % of output + 2 mv) After 30 ns < (0.5 % of output + 2 mv) Typical duty cycle 45 % to 55 % 3 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators

Leveled Sinewave Function Specifications 5520A-SC1100 (> 600 MHz) Characteristics into 50 Ω Adjustment Frequency 50 khz (reference) 600 MHz to 1.1 GHz Amplitude Characteristics 5 mv to 3.5 V < 100 mv: 3 digits; 100 mv: 4 digits Continuously Adjustable 1-year absolute uncertainty, tcal ± 5 C ± (2 % of output + 300 µv) ± (7 % of output + 300 µv) Flatness (relative to 50 MHz) 1 not applicable ± (5 % of output + 100 µv) Short-term amplitude stability 1 % 2 1-year absolute uncertainty, tcal ± 5 C Frequency Characteristics Distortion Characteristics 100 khz ± 2.5 ppm 2 nd harmonic -33 dbc 3 rd and higher harmonic -38 dbc 1 As measured near oscilloscope bandwidth frequency. 2 Within one hour after reference amplitude setting, provided temperature varies no more than ± 5 C. Leveled Sine Wave Characteristics into 50 (p-p) Frequency 50 khz (Reference) 50 khz to 100 MHz 100 MHz to 300 MHz ± (2 % of output + 300 µv) Amplitude ± (3.5 % of output + 300 µv) Flatness (relative to 50 khz) 1 Not applicable ± (1.5 % of output + 100 µv) 5 mv to 5.5 V Short-term amplitude stability 1 % 2 Frequency Distortion 10 khz ± 2.5 ppm 2 nd harmonic -33 dbc 3 rd and higher harmonics -38 dbc 1 As measured near oscilloscope bandwidth frequency. 2 Within one hour after reference amplitude setting, provided temperature varies no more than ± 5 C. ± (4 % of output + 300 µv) ± (2 % of output + 100 µv) 300 MHz to 600 MHz ± (6 % of output + 300 µv) ± (4 % of output + 100 µv) 4 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators

5500A-SC300 Leveled Sine Wave Characteristics Frequency into 50 W 50 khz (Reference) 50 khz to 100 MHz 100 MHz to 300 MHz 1 Amplitude (p-p) 5 mv to 5.5 V 1 ± (2 % of output + 200 µv) ± (3.5 % of output + 300 µv) ± (4 % of output + 300 µv) Flatness (relative to 50 khz) 1 Not applicable ± (1.5 % of output + 100 µv) ± (2 % of output + 100 µv) Short-term amplitude stability 1 % 2 Frequency 10 khz ± 2.5 ppm Distortion 2 nd harmonic -33 dbc 3 rd and higher harmonics -38 dbc 1 Extended frequency range to 350 MHz is provided, but flatness is not specified. Amplitude is limited to 3 V for frequencies above 250 MHz. 2 Within one hour after reference amplitude setting, provided temperature varies no more than ± 5 C. Time Marker Function Specifications Time Marker into 50 W 1 5 s to 50 ms 20 ms to 100 ns 50 ns to 20 ns 10 ns 5 ns to 2 ns 1-year absolute uncertainty, ± (25 + t* X 1000) tcal ± 5 C 2 ppm ± 2.5 ppm ± 2.5 ppm ± 2.5 ppm ± 2.5 ppm Wave shape Spike or square Spike, square, 20 %-pulse Spike or square Square or sine Sine Typical jitter (p-p) < 10 ppm < 1 ppm < 1 ppm < 1 ppm < 1 ppm 5-2-1 from 5 s to 2 ns (e.g., 500 ms, 200 ms, 100 ms) 1 Output amplitude > 1 V pk. 2 Time marker uncertainty is ± 50 ppm when measured off of cardinal points. *t = time in seconds. 5500A-SC300 Time Marker into 50 W 1 5 s to 100 µs 50 µs to 2 µs 1 µs to 20 ns 10 ns to 2 ns 1-year absolute uncertainty, tcal ± 5 C ± (25 + t* X 1000) pmm ± (25 + t* X 15000) pmm ± 25 ppm ± 25 ppm Wave shape Pulsed sawtooth Pulsed sawtooth Pulsed sawtooth Sine 5-2-1 from 5 s to 2 ns (e.g., 500 ms, 200 ms, 100 ms) 1 Typical amplitude > 1 V *t = time in seconds. Trigger Functions 5520A-SC1100, 5500A-SC600 and 5500A-SC300 Available for edge and time marker functions (volt, pulse and video are available for only). 5 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators

Wave Generator Function Specifications 5520A-SC1100, 5500A-SC600 and 5500A-SC300 Wave Generator Characteristics 10 Hz to 10 khz Amplitude Square Wave, Sine Wave, and Triangle Wave into 50 W or 1 MW Into 1 MΩ: 1.8 mv to 55 V p-p Into 50 Ω: 1.8 mv to 2.5 V p-p () Into 50 Ω: 1.8 mv to 2.2 V p-p (5500A-SC300) ± (3 % of p-p output + 100 µv) 1-2-5 (eg., 10 mv, 20 mv, 50 mv,...) Typical dc offset range 0 to ± ( 40 % of p-p amplitude) 1 1 The DC offset plus the wave signal must not exceed 30 V rms. Frequency 10 Hz to 100 khz 4 or 5 digits depending on frequency Pulse Generator Function Specifications The pulse generator is designed for oscilloscope capture function tests and trigger verification applications. Pulse Generator Characteristics Typical rise/fall times Amplitude available Positive Pulse into 50 W 2 ns Pulse Width 1 4 ns to 500 ns 1 Uncertainty 2 Discrete steps: 2.5 V, 1 V, 250 mv, 100 mv, 25 mv, 10 mv 5 % ± 2 ns Pulse Period 1 Pulse width not to exceed 40 % of period. 2 Pulse width uncertainty for periods less than 2 µs are not specified. 20 ms to 200 ns (50 Hz to 6.6 MHz) ± 2.5 ppm 6 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators

TV Trigger Specifications. TV Trigger is provided at the Scope Output Terminal Trigger Signal Type Parameters Frame formats Selectable NTSC, SECAM, PAL, PAL-M Polarity Selectable Inverted or Uninverted Video Amplitude into 50 W (p-p) Adjustable 0 to 1.5 V p-p into 50 W load, (± 7 % accuracy) Line marker Selectable Line Video Marker Input Impedance Measurement Specifications Uncertainty Resistance 40 W to 60 W 0.1 % 500 kw to 1.5 MW 0.1 % Capacitance 5 pf to 50 pf ± (5 % of input + 0.5 pf) 1 1 Measurements made within 30 minutes of capacitance zero reference. Scope option must be selected for at least five minutes prior to capacitance measurement or zero. Overload Measurement Specifications. The overload test function applies dc or ac (1 khz square wave) power into the 50 W oscilloscope input and monitors the current. A time measurement counter indicates the time duration of the applied overload signal. When the oscillosope's input protection circuit reacts and opens up the 50 W load, the calibrator indication is set to off on the right hand display. In order to prevent oscilloscope front end damage, a limited amount of energy is applied by a user settable time limit. Source Voltage Time Limit dc or 1 khz ac 5 V to 9 V Settable from 1 Sec to 60 Sec Typical On Current Indication Typical Off Current Indication 5 V to 9 V Settable from 1 Sec to 60 Sec External Frequency Reference Input (5522A only) The External Reference Input selection allows the user to provide their own high stability 10 MHz reference clock for the 5500A-SC600 and 5520A-SC1100 when fitted in a 5522A mainframe. All functions except Wave Generator and Marker greater than 50ms are then referenced to the external 10 MHz signal. The external reference input must be between 1 V to 5 V p-p. Uncertainty of output = uncertainty of reference + 5 µhz. 7 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators

STBY OPR EARTH SCOPE TRIG OUT p n p SHIFT dbm W PREV MENU sec F ENTER SETUP NEW REF MEAS TC MULT RESET ZERO CAL DIV EDIT Ordering Information Models 5502A Multi-Product Calibrator 5502A/3 Multi-Product Calibrator with 300 MHz Oscilloscope Calibration Option 5502A/6 Multi-Product Calibrator with 600 MHz Oscilloscope Calibration Option 5522A High-Performance Multi-Product Calibrator 5522A/6 High Performance Multi-Product Calibrator with 600 MHz Oscilloscope Calibration Option 5522A/1GHZ High Performance Multi-Product Calibrator with 1.1 GHz Oscilloscope Calibration Option Upgrades of oscilloscope calibration options into 55XX Series calibrators can be done at a Fluke Service Center. Contact a Fluke Service Center or your Fluke Calibration representative for details. Accessories 5500A/COIL 50-Turn Current Coil 9100-200 Dual 10 and 50 Turn Coil 55XX/CASE Roll-Aboard Transit Case 5522A/CARRYCASE Rugged Carrying Case with removable front/back panels 5500A/LEADS Comprehensive Test Lead Kit for 5502A 5520A-525A/LEADS Comprehensive Test Lead Set for 5522A 5500A/HNDL Side Carry Handle Y5537 Rack Mount Kit MET/CAL Calibration Software 5800A-7002K Two Piece Replacement Output Cable Set 5800A-7004K Oscilloscope Calibrator BNC Connector Kit Product Compatability Chart Model 5502A 5522A 5500A-SC300 5500A-SC600 5520A-SC1100 5502A CALIBRATOR +/ 7 8 9 4 5 6 1 2 3 0 43.2 cm (17 in) m V Hz FIELD k M Front view and dimensions. A C F x CE 17.8 cm (7 in) 47.0 cm (18.5 in) 6.4 cm (2.5 in) POWER For Cable Access Side view and dimensions. Note: 5502A and 5522A dimensions are the same. Fluke Calibration. Precision, performance, confidence. QUALITY MANAGEMENT SYSTEM ISO 9001 C E RT I FI E D T O M E E T IS O 9 0 01 Fluke Calibration PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (877) 355-3225 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.flukecal.com 1999-2012 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 7/2012 1265775G_EN Pub_ID: 10806-eng, Rev 03S 8 Fluke Calibration Oscilloscope Calibration Options for Fluke 55XX Series Multi-Product Calibrators Modification of this document is not permitted without written permission from Fluke Calibration.